BENEFITS
Model 56 Model 56
MAIN FEATURES
• Temperature range: +5 °C above ambient temperature to +300 °C • 2 chrome-plated racks
• Up to 30% lower energy consumption compared to conventional units on • Stackable
the market • Class 2 integrated independent adjustable temperature safety device
• High temperature accuracy thanks to APT.line™ technology (DIN 12880) with visual alarm
• Natural convection • Ergonomic handle design
• Controller with LCD display • USB port for recording data
• Electromechanical control of the exhaust air flap
ORDERING INFORMATION
TECHNICAL DATA
1 All technical data is specied for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage
fluctuation of ±10%. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances
of 10 % of the height, width, and depth of the inner chamber. All indications are average values, typical for units produced in series. We reserve the
right to change technical specications at any time.
OPTIONS
Calibration certificate, temperature measurement incl. certicate and 27 measuring points at specied temperature – 8012-1593
temperature temperature measurement incl. certicate, 15- 18 measuring points at specied temperature – 8012-1572
temperature measurement incl. certicate, 9 measuring points at specied temperature – 8012-1551
Class 3.1 independent
temperature safety with visual alarm (DIN 12880) – 8012-0985
device
Clock battery-backed – 8012-1640
Door gasket made of FKM, silicone-free – 8012-1008
Door lock lockable door handle – 8012-1664
Ethernet interface for Multi Management Soware APT-COM™ – 8012-1645
with 15 W light bulb
Interior lighting 120 V option model – 8012-1631
230/240 V option model – 8012-1627
Measurement of air
in accordance with ASTM D5374, denition and protocol according to ambient temperature – 8012-0195
exchange rate
Pt 100 temperature
additional flexible Pt 100, interior, for displaying the temperature on the unit display – 8012-1619
sensor
viewing window (triple insulating glass) in door, 240 x 240 mm, and 15 W interior
Viewing window and
120 V option model – 8012-1059
interior lighting
230 V option model – 8012-1058
* Notes › See last page
ACCESSORIES
APT-COM™ 4 BASIC- for simple logging and documentation requirements with up to 5 networked units.
Edition version 4, BASIC edition – 9053-0039
* Notes › See last page
APT-COM™ 4 convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units.
PROFESSIONAL-Edition version 4, PROFESSIONAL edition – 9053-0040
Ethernet interface for Multi Management Soware APT-COM™ – 8012-1645
pH-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg – 1002-0016
IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl.
calibration guide and comprehensive unit documentation; parameters: temperature, CO2, O2, pressure, depending on
unit
Digital in PDF format – 7057-0001
Hard copy inside folder – 7007-0001
Qualification documents
IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer
requirements, PQ section added to qualication folder IQ/OQ; parameters: temperature, CO2, O2 – or pressure,
depending on unit
Digital in PDF format – 7057-0005
Hard copy inside folder – 7007-0005
chrome plated – 8012-2039
Rack
stainless steel – 6004-0158
Rubber pads set anti-slip feet – 8012-2030
Shelf, perforated Stainless steel – 6004-0190
Table on castors stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm – 9051-0018
* Notes › See last page
SERVICES
03, 04,
Measurement of air exchange rate including certicate (in accordance with ASTM D5374) DL33-0000
05
Temperature measurement, 18 Temperature measurement with 18 measuring points with a set value specied by the user, including 03, 04,
DL30-0118
measuring points certicate 05
Temperature measurement, 27 Temperature measurement with 27 measuring points with a set value specied by the user, including 03, 04,
DL30-0127
measuring points certicate 05
Validation services
Execution of IQ/OQ Execution of IQ/OQ in accordance with qualication folder 05 DL40-0100
Execution of IQ/OQ/PQ Execution of IQ/OQ/PQ in accordance with qualication folder 05 DL44-0500
Warranty service
1-year warranty extension The warranty is extended by 1 year from the delivery date, wear parts are excluded – DL50-0010
* Notes › See last page
NOTES
01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge.
02 UL mark is not granted when this option is used.
03 Sensor calibration is performed in an accredited calibration laboratory.
04 Calibration is performed according to the BINDER factory standard.
05 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not
include a country-specic added fee (available on request).
BINDER GmbH BINDER Asia Pacific (Hong Kong) Ltd. Representative Office for CIS
Tuttlingen, Germany Kowloon, Hong Kong, P.R. China Moscow, Russia
TEL +49 7462 2005 0 TEL +852 39070500 TEL +7 495 988 15 16
FAX +49 7462 2005 100 FAX +852 39070507 FAX +7 495 988 15 17
[email protected] [email protected] [email protected]
www.binder-world.com www.binder-world.com www.binder-world.com