0% found this document useful (0 votes)
66 views72 pages

LNA08111 e

The document discusses Mitsubishi Electric's CC-Link IE Ethernet-based integrated network and iQ Platform. The CC-Link IE network supports seamless 1 Gbps communication within manufacturing environments. The iQ Platform minimizes total cost of ownership through improved development times, productivity, maintenance costs, and information access across plants. When combined with Mitsubishi's e-Factory solutions, the iQ Platform enhances manufacturing enterprise capabilities.

Uploaded by

Adonai Binghiman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views72 pages

LNA08111 e

The document discusses Mitsubishi Electric's CC-Link IE Ethernet-based integrated network and iQ Platform. The CC-Link IE network supports seamless 1 Gbps communication within manufacturing environments. The iQ Platform minimizes total cost of ownership through improved development times, productivity, maintenance costs, and information access across plants. When combined with Mitsubishi's e-Factory solutions, the iQ Platform enhances manufacturing enterprise capabilities.

Uploaded by

Adonai Binghiman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 72

Ethernet-based Open Network

CC-Link IE Product Catalog

Seamless connectivity within all levels of automation

Ethernet-based integrated network


Global Player

GLOBAL IMPACT OF
MITSUBISHI ELECTRIC

Through Mitsubishi Electric’s vision, “Changes for the Better“ are possible for a brighter future.

Mitsubishi Electric is involved in many areas including the following

We bring together the best minds to Energy and Electric Systems


create the best technologies. At A wide range of power and electrical products from generators to large-scale displays.
Mitsubishi Electric, we understand
that technology is the driving force of Electronic Devices
change in our lives. By bringing great- A wide portfolio of cutting-edge semiconductor devices for systems and products.
er comfort to daily life, maximizing the
efficiency of businesses and keeping Home Appliance
things running across society, we Dependable consumer products like air conditioners and home entertain-
integrate technology and innovation to ment systems.
bring changes for the better.
Information and Communication Systems
Commercial and consumer-centric equipment, products and systems.

Industrial Automation Systems


Maximizing productivity and efficiency with cutting-edge automation technology.

01
iQ Platform

iQ Platform for maximum return on investment


Minimize TCO, Seamless integration, Maximize productivity, Transparent communications: these are common items
that highlight the benefits of the iQ Platform and e-F@ctory. The iQ Platform minimizes TCO at all phases of the
automation life cycle by improving development times, enhancing productivity, reducing maintenance costs, and
making information more easily accessible across the plant. Together with e-F@ctory, offering various best-in-class
solutions through its e-F@ctory alliance program, the capabilities of the manufacturing enterprise is enhanced even
further realizing the next level for future intelligent manufacturing plants.

ERP (Enterprise resource planning)


MES (Manufacturing execution system)

ERP PAC & HMI


Integration of automation controller and HMI
ME
S
Network
Au Integrated network through seamless connectivity
to
Co mati

Features
ntr on
olle
r Engineering
Int
e Centralized engineering environment
Ne grate
tw d
ork
In
En tegr
gin ate
ee d

Applications
rin
g

Further reduce TCO while securing

Products
your manufacturing assets
Automation Controller Integrated Network Centralized Engineering
Improve productivity and product Best-in-class integrated Integrated engineering
quality network optimizing production environment with system level
capabilities features Options

1. High-speed system bus realizing 1. CC-Link IE supporting 1 Gbps 1. Automatic generation of system
improved system performance high-speed communication configuration
2. On-screen multi-touch control enabling 2. Seamless connectivity within all levels of 2. Share parameters across multiple
smooth GOT (HMI) operations manufacturing with SLMP engineering software via MELSOFT
Navigator
Development tool

3. Changes to system labels are reflected


between PAC and HMI
Product list

02
on
ral Moti
Gene

ty
Safe
less
ing Seam
e sav
Spac

time
Real-

bit
g Giga
wirin
Less
rnet
Ethe

Ring

Line Star
ize
hron
Sync

Extensive visualization General, motion Comprehensive


with advanced data and safety control diagnosis realizing
connectivity integrated into one higher reliability
network
Big Data analytics requires CC-Link IE incorporates generic Disruptions to the control
deterministic data collection, distributed control, synchronous system are kept to a minimum
which can be realized by motion control, and safety control via comprehensive diagnostics
incorporating two key features: enabling safety communications functions, high communications
SLMP*1 that enables seamless across multiple safety devices, integrity owing to the noise-
connectivity between devices in all on the same network. The resistant characteristics of the
the IT layer and on the shop floor; topology is quite versatile, based optical cable, and communication
and a high-speed, large-capacity on twisted-pair cables, which re-routing capabilities made
1 Gbps communications network enables flexibility in system possible as the result of using
that enables the handling of configuration while helping to a ring topology. Also, network
large-data, such as production, keep installation cost low. errors can be rectified quickly by
quality and control data between visualizing the network system
different production processes. image using the engineering
software*2, and remotely from
*1. Seamless Message Protocol a GOT (HMI) directly on the
*2. MELSEC iQ-R Series is supported by GX Works3.
MELSEC-Q Series and MELSEC-L Series are supported by GX Works2. machine or production line.

03
Seamless connectivity within all levels of automation
The backbone of e-F@ctory, leveraging connectivity between the
shop floor and IT

• Integrated generic and safety control


• Easy connection of servo amplifiers (with • Mix safety and non-safety remote
built-in position function) to the network devices on one network
• Monitoring data from servo amplifiers • Directly connect safety devices such as
collected in real-time by an IT system safety switches, and light-curtains

• High-accuracy synchronization
enabling advanced motion control
• Simplified engineering and
execution using motion function
blocks /RS
AS

ting
tes
and
tion
ica
ppl
ea
ing past
kag der
Pac Sol
ce
pla
ly and
mb ick
sse Tp
al a SM
Fin

n
ove
low
Ref
on
ecti
insp
ing
lder
t-so
Pos
• Main line controller regulating all
network devices across production
• Ethernet-based open network
realizing seamless communication
(SLMP) across multiple networks
• Monitoring and setup of inverters
• On-machine direct connectivity to • Seamless integration of stand-alone throughout the network
sensors via remote devices machines to main plant-wide control
network
• Monitor various automation devices on
the network directly from the HMI

04
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable

High-speed communications realizes shorter and more stable operating cycle,


enabling higher productivity
•• Shorten the operating cycle
•• Improve productivity
•• Extensive traceability
High-speed 1 Gbps communication

◾◾High-speed communication enabling shorter operating cycle


The transfer rate of 1 Gbps results in high-speed „Example based on CC-Link IE Field Network

communications (controller-to-controller and controller-


to-field device), thereby reducing operating cycle time.
MELSEC iQ-R/Q/L Series
The network, which accommodates general high-
speed I/O control, can also accommodate control of 1Gbps
distributed controllers in multiple fields, enabling simple
network configuration. This network is fully capable
of transmitting large volume of data, which can be
handled by high-function field devices. With the ability PULL

to transfer large amounts of traceability data, a system MELSEC-Q MELSEC iQ-R MELSEC-L MELSEC-L
Series Series Series Series
capable of highly-detailed diagnostics can also be
realized.
Stable cyclic communication

◾◾Improve productivity
The 1 Gbps bandwidth is divided between deterministic Cyclic communication area (for control data)
(cyclic) and transient (message) communications. Deterministic
Cyclic communications, which is used for I/O control is
deterministic and its performance will not degrade even 1 Gbps
when large volumes of traceability and diagnostic data
are transferred via transient communication.
Transient (message) area (for information data)

Real-time collection of shop floor data


•• Integrate PLM*1 tools
•• Identify shop floor activities speedily, accurately, and efficiently
Integrated network

◾◾Backbone of e-F@ctory, connecting shop floor and IT


All the systems related to factory production, quality, and safety are integrated into one network, helping to
visualize and process factory floor (shop floor) data. Data obtained on the factory floor is transmitted to the
IT system for analysis or further processing, and then the result can be sent back, realizing a bidirectional
communications flow optimizing operations management.
IT system
Simulator SCM ERP
SCADA CAD CAM

Ethernet

Production

IT interface
Process acquired data,
Shop floor data
MES interface GOT (HMI)
sending result to shop
acquisition in real-time
module MES interface function embedded floor devices

Controllers Drives Energy-saving products Mechatronics

*1. Product Lifecycle Management.

05
Reduce installation cost with widely-available Ethernet components
•• Use widely-available components for overseas production sites
•• Procure system components for less
Ethernet-based network

◾◾Built on global standards


CC-Link IE has been designed to make use of widely-available Ethernet components including cables, connectors,
and adapters. Thanks to the common availability of these components, network configuration cost can be saved.
„Twisted-pair cable configuration

Computer

Ethernet adapter
Master
station Wireless LAN adapter

Ethernet
switching HUB Label printer

1 Gbps
Vision sensor Ethernet devices compatible
with Seamless Message
Q06UDEHCPU
Protocol (SLMP)*1

Bar-code reader

Features
RFID controller
100 M/1 Gbps

Relay adapter

Applications
Ethernet switching HUB Ethernet cable connector Relay adapter

The Ethernet adapter unit realizes connection of SLMP*1 compatible Ethernet devices to a CC‑Link IE Field

Products
Network. Various devices can be connected such as vision sensors and RFID controllers.
*1. SLMP (Seamless Message Protocol): Is a client/server protocol that enables communications between Ethernet-ready and CC-Link IE compatible devices

„Optical cable configuration

Options

Relay adapter

Relay adapter

Easily configure
Extending the system additional stations
Development tool

Ethernet cable connector Relay adapter


Product list

06
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable

Easily modify existing control system configurations


•• Supporting frequent modifications of the production line
•• Configure equipment more flexibly
Flexible network topology

◾◾Reconfigure existing systems to match production changes


Multiple network topologies are supported including star, line, ring*1, star and line combinations. This flexibility
allows additional equipment to be simply connected to any available port, with little concern for restrictions.

PW RUN
L ER
MODE D
LINK ERR.
P1Y0
1 2
3 Y4
LINK 5 6
X10
7 Y8
9 A
O/G 0 1 X1
B YC
TEST 2
D E
9 0 STATION F I/O
12 3 1 NO. PW
L11ER 4 8
10 5 7 +24V 2
P2 9 8 7 6 6
3
5 4
24G
LINK NZ2GF
2B1-16
(FG) T
1
3
5
7
9
11
2 13
4 15
6 17
8
10
12
14
16
18

PW RUN
L ER
MODE D
LINK ERR.
P1Y0
1 2
3 Y4
LINK 5 6
X10
7 Y8
9 A
O/G 0 1 X1
B YC
TEST D E
2 9 0 STATION F I/O
12 3 1 NO. PW
L11ER 4 8
10 5 7 +24V 2
P2 9 8 7 6 6
3
5 4
24G
NZ2GF

Star topology
LINK
2B1-16
(FG) T
1
3
5
7
9
11
2 13
4 15
6 17
8
10
12
14
16
18

Ethernet switching HUB


New devices can be added
by simply connecting to an
available port

Q06UDEHCPU

PW RUN
L ER PW RUN
L ER PW RUN
L ER
MODE D MODE D MODE D
LINK ERR. LINK ERR. LINK ERR.
P1Y0 P1Y0 P1Y0
1 2 1 2 1 2
3 Y4 3 Y4 3 Y4
LINK 5 6 LINK 5 6 LINK 5 6
X10
7 Y8 X10
7 Y8 X10
7 Y8
9 A 9 A 9 A
O/G 0 1 X1
B YC O/G 0 1 X1
B YC O/G 0 1 X1
B YC
TEST D E TEST D E TEST D E
2 9 0 STATION F I/O 2 9 0 STATION F I/O 2 9 0 STATION F I/O
12 3 1 NO. PW 12 3 1 NO. PW 12 3 1 NO. PW
L11ER 4 8 L11ER 4 8 L11ER 4 8
10 5 7 +24V 2 10 5 7 +24V 2 10 5 7 +24V 2
P2 9 8 7 6 6
3 P2 9 8 7 6 6
3 P2 9 8 7 6 6
3
5 4 24G 5 4 24G 5 4 24G
LINK NZ2GF LINK NZ2GF LINK NZ2GF
2B1-16 2B1-16 2B1-16
(FG) T (FG) T (FG) T
1 1 1
3 3 3
5 5 5
7 7 7
9 9 9
11 11 11
2 13 2 13 2 13
4 15 4 15 4 15
6 17 6 17 6 17
8 8 8
10 10 10
12 12 12
14 14 14
16 16 16
18 18 18

Line topology

Ring topology

Q06UDEHCPU

1
2
3
4
5
6
7
8

*1. Cannot be mixed with star or line topology.

07
Synchronization performance for advanced motion control
•• Integrate networks of a motion control system in one network
•• Support advanced machines and systems
High-accuracy synchronization performance

◾◾High-accuracy synchronization performance for advanced motion control


CC-Link IE Field Network, which supports high-accuracy synchronization, enables advanced motion control as
well as I/O control in one network. I/O control synchronized with the motion control can increase the productivity of
the machine and the entire system.

GOT (HMI)

MR-J4-GF MR-J4-GF-RJ

High-speed counter module

Features
Synchronous
encoder
Mark
sensor

Output module

Applications
Printer

Products
Analog module

Options
Development tool
Product list

08
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable

Integrating safety communication on one network


•• Enable network communication between Safety CPUs
•• Manage standard and Safety CPUs under one network
Safety communication

◾◾Safety and non-safety communications on the same network


The MELSEC iQ-R Series Safety CPU enables both safety and non-safety communications on the same CC-Link
IE Field Network. Connectivity to generic and safety control systems can be done without requiring a dedicated
safety network which can increase system hardware cost.
Note: The safety communication function and submaster function cannot be used together.
Safety communication between a MELSEC iQ-R Series Safety station and a MELSEC-QS Series Safety station is not supported.

Generic CPU (non-safety) Generic CPU (non-safety) Generic CPU (non-safety)


Local station Local station Local station

Generic (non-safety) communication

Safety communication Ethernet switching HUB

Safety CPU Generic CPU (non-safety)


Master station Local station

Safety Generic (non-safety)


communication communication
Safety I/O Generic (non-safety) I/O Safety I/O Generic (non-safety) I/O

Safety Generic Safety Generic


remote I/O remote I/O remote I/O remote I/O
module module module module

09
Improve reliability with reduced single-point failure
•• Maintain communications during an error

High availability system

◾◾Improve reliability with redundant system


A multi-level redundant system can be realized by installing dual control systems consisting of the control (primary)
and standby CPUs combined with a dual cable topology for the network cabling of the CC-Link IE Field networks,
and dual remote stations minimizing the risk of singe-point failure.

Switching of the control system to the


standby system if an error occurs with
the control system

Control system Standby system

Tracking cable

Features
Redundant network cable and communications module
ensure continuous operation in the event of an error

Applications
Products
Remote station Remote station

Options
Development tool
Product list

10
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable

Reduced starting time shortens production cycle


Fast link-up function

◾◾Reduce starting time with fast link-up function


A remote module supporting fast link-up function*1 enables the disconnected station to return quickly when
reconnected with the CC-Link IE Field Network after disconnection. In the system where a tool change mechanism
(such as a tool changer) is used, reducing the starting time shortens production cycle time.

Robot Tool changer

NO. FUNCTION
1 AUTO PRM
ON 2 F LINK P1
3 F LINK P2
4 –

1234

NO. FUNCTION
1 AUTO PRM
ON 2 F LINK P1
3 F LINK P2
4 –

1234

Change tools according


to applications
In use
Master station

NO. FUNCTION NO. FUNCTION NO. FUNCTION


1 AUTO PRM 1 AUTO PRM 1 AUTO PRM
ON 2 F LINK P1 ON 2 F LINK P1 ON 2 F LINK P1
3 F LINK P2 3 F LINK P2 3 F LINK P2
4 – 4 – 4 –

1234 1234 1234

*1. For applicable modules, please refer to CC-Link IE Field Network Block type remote modules on page 24.

Seamless integration of devices supporting TCP/IP


•• Keep wiring cost low
•• Easy addition of Ethernet-ready devices
IP packet relay function

◾◾Perform TCP/IP communication under CC-Link IE Field Network


Communication with a designated IP address is possible under CC-Link IE Field Network. Wiring costs can be
reduced since there is no need to additionally install an extra Ethernet line along the CC-Link IE Field Network.

Ethernet supporting devices


SLMP communication
Devices supporting SLMP

Main server MELSEC iQ-R/Q/L CPU Ethernet


Master/local module adapter unit
Bar-code reader Vision sensor
Ethernet Ethernet

Devices supporting TCP/IP


Combine two
networks into one! Reduce costs with
simple wiring!

Robot Computer
TCP/IP communication
Seamlessly connect to TCP/IP
devices via CC-Link IE Field Network.

11
Flexible I/O point extension
Extension function

◾◾Easily increase I/O points by adding extension modules


Extension function Fast logic function
Extension modules are used to increase the number of Output control in accordance with the input status
available I/O points by simply attaching it to the main is possible in I/O module without going through the
I/O module, such as digital I/O, analog I/O, and high- master station.
speed counter modules.
Main module*1 Extension module*1 Select switch Photoelectric sensor

Input signal

High-speed response
Input module
Extension input module
Output module Output signal
Extension output module
High-speed counter module Coating application
Extension analog input module Enable Boolean logic*2
Analog input module Extension analog output module between two inputs
Analog output module Extension input module
Photoelectric sensor
Extension output module
*2. Both AND logic and OR logic are supported as an output state.

*1. Extension modules which can connect multiple extension modules are available. For applicable

Features
modules, please refer to CC-Link IE Field Network block type remote modules on page 24.

Simple network commissioning


•• Set up network parameters from one place
•• Create the desired operation by following easy-to-follow configuration steps

Applications
Easy setup

◾◾Network commissioning by parameter setup only


Setting of parameters via the engineering software*3 is quite easy with the master station (for CC-Link IE Field
Network) or control station (for CC-Link IE Control Network) requiring registration of parameters only. Both these
head stations hold the necessary network parameters to enable network communication with other nodes.

Products
„Example based on CC-Link IE Field Network

Registration of parameters
at Master station only

Options

Master
station Transfer Transfer
parameters
Development tool

Transfer Transfer Transfer

Master station Station No. 1 Station No. 2 Station No. 3 Station No. 4
Product list

*3. MELSEC iQ-R Series is supported by GX Works3.


MELSEC-Q Series and MELSEC-L Series are supported by GX Works2.

12
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable

Quickly identify wiring and module errors


•• Easily identify the location of errors
•• Remotely identify error details
Easy diagnosis function

◾◾Diagnose and troubleshoot even with limited knowhow of CC-Link IE


The engineering software*1 enables the easy identification of network errors. Route-cause analysis can be done
quickly enabling minimum disruption to the control system. Graphical representation of the network is automatically
created on the engineering software, making wiring and PLC errors clearly visible. Monitoring is also available on
other stations via the network, enabling detection of overlapping station numbers and miswiring at the time that
changes are made.

Engineering software

Quick detection of configuration errors in real-time

Repeated station number

Local station No. 1 Local station No. 1


Cable disconnection

Intelligent device station No. 3 Local station No. 4 Local station No. 5
*1. MELSEC iQ-R Series is supported by GX Works3.
MELSEC-Q Series and MELSEC-L Series are supported by GX Works2.

Avoiding entire network outage


•• Avoid disruption to control system
•• Maintain communications during an error
Submaster control, control station switching

◾◾Maintain data communications even if master (control) station stops


In the event that the ‘master or control station’*2 develops an error, the ‘sub-master or sub-control’*3 station takes
over control of the network, ensuring continued network communications even when these nodes are lost.
❶ Master (control) station ❷ Network control shifted to ❸ Continues data communications
operating normally sub-master (sub-control) station

Error occurs Master (control) Sub-master (sub-control)


station station
Master (control) Error
station stops
Control system failure averted

*2. Referred to as the “Master station” for CC-Link IE Field network, and “Control station” for CC-Link IE Control network.
*3. Referred to as the “Sub-master station” for CC-Link IE Field network, and “Sub-control station” for CC-Link IE Control network.

13
Exceptionally fault-tolerant dual-loop optical cable
•• Reduce the noise influence
•• Maintain communications during an error
Highly-reliable loop topology

◾◾Fault-tolerant network
Dual-loop optical cables that provide noise-immunity to Electromagnetic Interference (EMI) and Radio Frequency
Interference (RFI) are used. These robust cables include a loop-back function which ensures data communication
even when there is a cable disconnection or the power supply is lost. In addition, an external power supply can
be connected to modules supporting this feature, ensuring communications even if connection to the controller or
computer is lost.
Loop-back function*1

Loop back

Faulty cable

Features
Loop-back function maintains communication

Using an external power supply External power


External power External power supply
supply supply Computer power failure
External power supply maintains

Applications
the communication line

Power supply lost

Products
External power External power External power Communications maintained
supply supply supply even if between two faulty stations
*1. Loop-back function is supported when using ring topology with twisted-pair cable (both CC-Link IE Field and Control network).

Options
Development tool
Product list

14
A p p l i c a t i o n s

Semiconductor production system

◾◾Seamless communication
Centralized system operation and
monitoring

◾◾Flexible wiring
Various equipment layouts by a
combination of star and bus topologies

◾◾CC-Link integration
Connectable with various products
supporting CC-Link

Seamless communications enabling


system-wide control and monitoring

Main control panel Main controller


(master station)

Ethernet
switching HUB
Star topology
simplifying
maintenance of
chamber wiring

High-speed distributed control


between chambers
Choose a best-fit
network topology

CC-Link IE
- CC-Link Digital I/O Inverter Servo amplifier
bridge Analog I/O
module
RF power RF power
supply supply

Valve Mass flow


control controller

Chamber control panel Power supply control panel

Various products supporting CC-Link Remote I/O allows I/O to be used


without requiring a CPU

15
Automotive paint shop (Safety system)

◾◾Safety communication
between different
processes
Safety control is coordinated between
different processes

◾◾Integration of non-safety
communications
Generic and safety control is performed on
one network

— Safety I/O —

Features
Control area 1 (Main) Control area 2 Control area n

Enabling switch

Generic CPU Generic CPU


Safety CPU (non-safety) (non-safety)

Emergency stop
switch

Applications
Light curtain

Door switch
Generic (non-safety) I/O Generic (non-safety) I/O Generic (non-safety) I/O

— Generic (non-safety) I/O —

Products
Safety Safety Generic Generic
remote I/O remote I/O remote I/O remote I/O
Switch

Indicator light

Safety I/O Safety I/O Generic (non-safety) I/O Generic (non-safety) I/O

Options

p
Development tool

nt Sho ition
)
Pai ctro
-depos

oat (ele
E-C
g
Pa intin
Product list

ing
Cur

et
ern
Eth

16
A p p l i c a t i o n s

Flat panel display (FPD) production process

◾◾Super high speed


1 Gbps communication speed enables
high‑speed data transfer

◾◾Large capacity
Large volume of recipe and traceability
data is transmitted together with cyclic
communication

◾◾Cyclic communication
Cyclic communication bandwidth is fixed
realizing deterministic control even when
transient communications are varied

IT system Database server Ethernet

128K word communications


128K word shared memory enables
bandwidth between stations enables
system-wide monitoring and
transmission of large recipe data acquisition of large-bandwidth
traceability data

1Gbps Recipe data transmission Traceability data acquisition

Filling and
Cleaning Exposure Inspection Etching Resist stripping assembly

17
Steel production process

◾◾Large capacity
Large volume of recipe and traceability data is
transmitted together with cyclic communication
(1 Gbps)

◾◾Distributed control
Data is distributed between multiple controllers,
realizing high traceability

◾◾Highly-reliable
Realize highly-reliable system using redundant
CPUs, dual-loop optical network, and external
power supply

Features
1Gbps

Applications
Highly reliable communications
via dual-loop optical cable

Products
Tracking cable

Redundant system
enabling Options
high-reliability control
System-wide monitoring
from computer or HMI (GOT)

Pickling Cold rolling Plating Coating


Development tool

(acidic cleaning)
Product list

18
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable

◾◾CC-Link IE embedded CPU modules


R04ENCPU R08ENCPU R16ENCPU
R32ENCPU R120ENCPU
•• CPU module with CC-Link IE embedded
•• Dual Ethernet ports on the network side enable the module to operate Network
side
as an Ethernet or CC-Link IE Field Network master/local station, or as a Ethernet
CC-Link IE Control Network control/normal station port (P1)
•• The Ethernet port on the CPU side is used as an Ethernet
Ethernet
communications port port (P2)
•• Dual Ethernet ports on the network side can be used as a gateway
CPU side
Ethernet
◼ Network combination*1
port
C : CC-Link IE Control Network R120ENCPU
P1 C F E E
F : CC-Link IE Field Network
P2 C F C F E : Ethernet
*1. The CC-Link IE Field and CC-Link IE Control networks
cannot be used together.

◾◾Multi-network supporting Ethernet module


RJ71EN71*2
•• Dual Ethernet ports enable the module to operate as an Ethernet or
CC-Link IE Field Network master/local station, or a CC-Link IE Control
Network control/normal station Ethernet
port (P1)

◼ Network combination*3 Ethernet


C : CC-Link IE Control Network port (P2)
P1 C F E E E
F : CC-Link IE Field Network
P2 C F C F E E : Ethernet
*2. Safety communications is not supported.
*3. The CC-Link IE Field and CC-Link IE Control networks
cannot be used together.

◾◾CC-Link IE Field Network master/local modules


RJ71GF11-T2 QJ71GF11-T2 LJ71GF11-T2
•• These modules can be used either as a CC-Link IE Field Network
master or local station
•• The station-based block data assurance feature ensures data integrity
between stations (Output delay can be shortened by synchronization
with END processing)
•• In combination with a MELSEC iQ-R Series Safety CPU,
RJ71GF11-T2 can be used as a safety master/local station

QJ71GF11-T2
RJ71GF11-T2 LJ71GF11-T2

19
◾◾CC-Link IE Control Network modules
RJ71GP21-SX QJ71GP21-SX QJ71GP21S-SX
•• These modules can be used either as a CC-Link IE Control
Network control or normal station
•• Enables connection of an external power supply
(QJ71GP21S‑SX), which ensures communication even if the
controller power is lost
•• The station-based block data assurance feature ensures data
integrity between stations

RJ71GP21-SX QJ71GP21-SX QJ71GP21S-SX


Module with external power
supply I/P terminal

◾◾CC-Link IE Field Network simple motion modules


RD77GF4 RD77GF8 RD77GF16 RD77GF32 NEW
QD77GF4 QD77GF8 QD77GF16
•• Perform control of high-speed I/O and motion in one network, and
provide a suitable system layout with highly flexible wiring

Features
•• Perform advanced motion control such as synchronous, cam, and
positioning control including trajectory control
•• Can be used as a CC-Link IE Field Network master station*1
*1. RD77GF does not support the sub-master and safety communication functions.
QD77GF does not support the local, sub-master, and safety communication functions

Applications
RD77GF32 QD77GF16

◾◾CC-Link IE Field Network remote head module*2

Products
RJ72GF15-T2
•• A remote station can be realized through a combination of MELSEC
iQ-R Series I/O and intelligent function modules used together with this
module
•• Through its flexibility in system design, a remote station can be created
Options
based on the application size
•• Can access other stations on the network via USB port and perform
parameter setting and monitoring, saving on system configuration time
*2. For details of applicable modules, please refer to the relevant product manual.

RJ72GF15-T2
Development tool

Supports up to 64 MELSEC iQ-R Series I/O


modules and intelligent function modules per
station.
Product list

20
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted pair cable optical cable

◾◾CC-Link IE Field Network head module*1


LJ72GF15-T2
•• A remote station can be realized through a combination of MELSEC-L
Series I/O and intelligent function modules used together with this
module
•• Through its flexibility in system design, a remote station can be created
based on the application size
•• Can access other stations on the network via USB port and perform
parameter setting and monitoring, saving on system configuration time
*1. For details of applicable modules, please refer to the relevant product manual.

Supports up to 10 MELSEC-L Series I/O modules and


intelligent function modules per station.

◾◾CC-Link IE Field Network


intelligent device station module
FX5-CCLIEF
•• Enables connection of MELSEC iQ-F Series to CC-Link IE Field Network
as an intelligent device station
•• Connectable to high-speed and high-capacity CC-Link IE Field Network,
which also supports distributed controls, realizing shorter operating cycle
time and improved traceability
•• Supports seamless communication, which enables setup and
maintenance from any network-connected point including a computer
and shop floor device

21
◾◾AC Servo MELSERVO-J4 Series
„CC-Link
„ IE Field Network compatible servo amplifier
MR-J4-GF(-RJ)
•• CC-Link IE Field Network function embedded
•• Combined with the Simple Motion module, the servo amplifier can
perform synchronous and interpolation control, in addition to speed and
torque control
•• With a master module, the servo amplifier can perform positioning
operations just as easy as I/O operations, by using the point table
method (positioning operations are performed based on the point table
No. and start signal, without using a positioning module)

Compatible servo motor


Model*1 Voltage class Motor rated output Fully closed loop control
Rotary Linear Direct drive*2
MR-J4-□GF 200 V 0.1…22 kW ● ● ● ●
MR-J4-□GF4 400 V 0.6…22 kW ● ● ● -
MR-J4-□GF-RJ 200 V 0.1…22 kW ● ● ● ●
MR-J4-□GF4-RJ 400 V 0.6…22 kW ● ● ● -
*1. "□" in the model name denotes rated output. For further details about model name, please refer to the "MELSERVO-J4 catalogue (L(NA)03058ENG)"
*2. Low-profile direct drive motor TM-RG2M Series and TM-RU2M Series will be supported in the future.

Features
◾◾Inverter FREQROL-A800 Series
„CC-Link
„ IE Field Network compatible inverter
FR-A800-GF

Applications
•• CC-Link IE Field Network function embedded
•• High-speed communication of CC-Link IE Field Network realizes various
inverter operations to be monitored at a fast rate (multiple monitoring
and parameter reading/writing can also be executed simultaneously
improving maintainability)
•• Seamless network environment enables monitoring and setup of

Products
inverters from the IT system

Model*3 Voltage class Capacity Structure/functionality


FR-A820-□K-GF 200 V 0.4…90 kW Standard model
FR-A840-□K-GF 400 V 0.4…280 kW Standard model
FR-A842-□K-GF 400 V 315…500 kW Separated converter type
*3. "□" in the model name denotes rated output. For further details about model name, please refer to the "FR-A800 catalogue (L(NA)06075ENG)". Options
Development tool
Product list

22
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted pair cable optical cable

◾◾HMI GOT2000 Series


„CC-Link
„ IE Field Network communication unit set
GT27◻◻-◻◻◻◻-GF GT25◻◻-◻◻◻◻-GF
•• This product-set includes a GOT2000 series GOT (GT27 or GT25) and a
CC-Link IE Field Network communication unit
•• Integrates the HMI (GOT) into a system as a CC-Link IE Field Network
intelligent device station
•• The CC-Link IE Field Network communication unit (GT15‑J71GF13-T2) is
also available separately (Supported by GT27, GT25)

Model*1 Screen size Panel color Power supply Multi-touch gesture functions
GT2715-XTBA-GF 15"XGA Black 100 to 240 V AC ●
GT2715-XTBD-GF 15"XGA Black 24 V DC ●
GT2712-ST□A-GF 12.1"SVGA Black/white 100 to 240 V AC ●
GT2712-ST□D-GF 12.1"SVGA Black/white 24 V DC ●
GT2710-STBA-GF 10.4"SVGA Black 100 to 240 V AC ●
GT2710-STBD-GF 10.4"SVGA Black 24 V DC ●
GT2710-VT□A-GF 10.4"VGA Black/white 100 to 240 V AC ●
GT2710-VT□D-GF 10.4"VGA Black/white 24 V DC ●
GT2708-STBA-GF 8.4"SVGA Black 100 to 240 V AC ●
GT2708-STBD-GF 8.4"SVGA Black 24 V DC ●
GT2708-VTBA-GF 8.4"VGA Black 100 to 240 V AC ●
GT2708-VTBD-GF 8.4"VGA Black 24 V DC ●
GT2705-VTBD-GF 5.7"VGA Black 24 V DC ●
GT2512-STBA-GF 12.1"SVGA Black 100 to 240 V AC -
GT2512-STBD-GF 12.1"SVGA Black 24 V DC -
GT2510-VT□A-GF 10.4"VGA Black/white 100 to 240 V AC -
GT2510-VT□D-GF 10.4"VGA Black/white 24 V DC -
GT2508-VT□A-GF 8.4"VGA Black/white 100 to 240 V AC -
GT2508-VT□D-GF 8.4"VGA Black/white 24 V DC -
*1. "□" in the model name denotes panel color (B (black)/W (white)). For further details about model name, please refer to the "GOT 2000 Series consolidated catalogue (L(NA)08270ENG)".

„CC-Link
„ IE Control Network communication unit
GT15-J71GP23-SX
•• HMI (GOT) communication unit for CC-Link IE Control Network
•• Integrates a HMI (GOT) as a normal station of CC-Link IE Control
Network

Supported by: GT27, GT25

23
◾◾CC-Link IE Field Network Block type remote modules

•• These modules are useful when installation positions close to I/O devices are required
•• Connectable to extension modules, which increases the number of I/O points
•• Supports CC-Link IE Field Network synchronized communication (By synchronizing with the master station*1*2,
which supports synchronized communication, these modules perform highly-accurate synchronous operations
as slave stations.)
•• Modules*3 supporting fast link-up function quickly return when reconnected with the CC-Link IE Field Network
after disconnection
•• Modules*3 supporting automatic I/O parameter setting can be operated without setting parameters, thereby
reducing the start-up timing
*1. MELSEC iQ-R Series and simple motion module master stations support this feature.
*2. When using QD77GF16, this function cannot be used depending on the combination of the I/O module and software package used. For further details, please refer to the block type remote module
manual.
*3. For applicable modules, please refer to function list on P.29.

Main input modules


•• Response time can be set at 0 ms, 0.2 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms

Features
•• High-speed I/O control is realized with the Fast logic function through a combination of an extension output
module

Applications
Spring clamp terminal block type

NZ2GF2S1-16D
NZ2GF2S1-16D

Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GF2S1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire 1

Products
NZ2GF2S2-16A NEW

Rated input voltage,


Model Input type Input points Rated input current Wiring type Max. extension modules
frequency
8.2 mA (100 V AC, 60 Hz)
NZ2GF2S2-16A AC input 16 points 100…120 V AC, 50/60 Hz 2-wire 1
6.8 mA (100 V AC, 50 Hz)

Options

Screw terminal block

NZ2GF2B1N1-16D
NZ2GF2B1-32D NEW
Development tool

NZ2GF2B1-32D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GF2B1N1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire 3
NZ2GF2B1-32D Positive common Negative common 32 points 24 V DC (6 mA) 1-wire -

NZ2GF2B2-16A NEW
Product list

Rated input voltage,


Model Input type Input points Rated input current Wiring type Max. extension modules
frequency
8.2 mA (100 V AC, 60 Hz)
NZ2GF2B2-16A AC input 16 points 100…120 V AC, 50/60 Hz 2-wire 1
6.8 mA (100 V AC, 50 Hz)

24
P r o d u c t s

Sensor connector (e-CON) type

NZ2GFCE3-16D
NZ2GFCE3-16DE
NZ2GFCE3-32D NZ2GFCE3-16D

Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCE3-16D Positive common 16 points 24 V DC (4 mA) 3-wire 1
NZ2GFCE3-16DE Negative common 16 points 24 V DC (4 mA) 3-wire 1
NZ2GFCE3-32D Positive common 32 points 24 V DC (4 mA) 3-wire 1

MIL connector type

NZ2GFCM1-16D
NZ2GFCM1-16DE
NZ2GFCM1-16D

Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCM1-16D Positive common 16 points 24 V DC (4 mA) 1-wire 1
NZ2GFCM1-16DE Negative common 16 points 24 V DC (4 mA) 1-wire 1

40-pin connector type

NZ2GFCF1-32D
NZ2GFCF1-32D

Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCF1-32D Positive common Negative common 32 points 24 V DC (4 mA) 1-wire 1

25
Main output modules
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function
•• High-speed I/O control is realized with the Fast logic function through a combination of an extension input
module

Spring clamp terminal block type

NZ2GF2S1-16T
NZ2GF2S1-16TE NZ2GF2S1-16T

Rated load voltage/


Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GF2S1-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire 1
NZ2GF2S1-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire 1

NZ2GF2S2-16R NEW

Model Output type Output points Rated switching voltage/current Wiring type Max. extension modules
NZ2GF2S2-16R Contact output 16 points 24 V DC (2 A) 240 V AC (2 A) 2-wire 1

NZ2GF2S2-16S NEW

Features
Rated load voltage, frequency/
Model Output type Output points Wiring type Max. extension modules
Max. load curent
NZ2GF2S2-16S Triac output 16 points 100…240 V AC, 50/60 Hz (0.6 A) 2-wire 1

Screw terminal block

Applications
NZ2GF2B1N1-16T NZ2GF2B1-32T NEW
NZ2GF2B1N1-16TE NZ2GF2B1-32TE NEW NZ2GF2B1-32T
Rated load voltage/
Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GF2B1N1-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire 3

Products
NZ2GF2B1N1-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire 3
NZ2GF2B1-32T Sink type 32 points 12/24 V DC (0.5 A) 1-wire -
NZ2GF2B1-32TE Source type 32 points 12/24 V DC (0.5 A) 1-wire -

NZ2GF2B2-16R NEW

Model Output type Output points Rated switching voltage/current Wiring type Max. extension modules
NZ2GF2B2-16R Contact output 16 points 24 V DC (2 A) 240 V AC (2 A) 2-wire 1
Options

NZ2GF2B2-16S NEW

Rated load voltage, frequency/


Model Output type Output points Wiring type Max. extension modules
Max. load current
NZ2GF2B2-16S Triac output 16 points 100…240 V AC, 50/60 Hz (0.6 A) 2-wire 1
Development tool
Product list

26
P r o d u c t s

Sensor connector (e-CON) type

NZ2GFCE3-16T
NZ2GFCE3-16TE
NZ2GFCE3-32T NZ2GFCE3-16T

Rated load voltage/


Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GFCE3-16T Sink type 16 points 12/24 V DC (0.5 A) 3-wire 1
NZ2GFCE3-16TE Source type 16 points 12/24 V DC (0.5 A) 3-wire 1
NZ2GFCE3-32T Sink type 32 points 12/24 V DC (0.5 A) 3-wire 1

MIL connector type

NZ2GFCM1-16T
NZ2GFCM1-16TE
NZ2GFCM1-16T

Rated load voltage/


Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GFCM1-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire 1
NZ2GFCM1-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire 1

40-pin connector type

NZ2GFCF1-32T
NZ2GFCF1-32T

Rated load voltage/


Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GFCF1-32T Sink type 32 points 12/24 V DC (0.1 A) 1-wire 1

27
Main I/O combined modules
•• The I/O combined module controls both inputs and outputs all in one module
•• Response time can be set at 0 ms, 0.2 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function
•• High-speed I/O control is realized with the Fast logic function

Screw terminal block

NZ2GF2B1-32DT NEW
NZ2GF2B1-32DTE NEW
NZ2GF2B1-32DT

Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
NZ2GF2B1-32DT Positive common 16 points 24 V DC (6 mA) Sink type 16 points 24 V DC (0.5 A) 1-wire -
NZ2GF2B1-32DTE Negative common 16 points 24 V DC (6 mA) Source type 16 points 24 V DC (0.5 A) 1-wire -

Sensor connector (e-CON) type

Features
NZ2GFCE3-32DT
NZ2GFCE3-32DT

Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
NZ2GFCE3-32DT Positive common 16 points 24 V DC (4 mA) Sink type 16 points 12/24 V DC (0.5 A) 3-wire 1

Applications
40-pin connector type

NZ2GFCF1-32DT
NZ2GFCF1-32DT

Products
Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
Positive common
NZ2GFCF1-32DT 16 points 24 V DC (4 mA) Sink type 16 points 12/24 V DC (0.1 A) 1-wire 1
Negative common

Options
Development tool
Product list

28
P r o d u c t s

CC-Link IE Field Network Block type remote modules function list*1


Synchronized I/O parameter
Type Model Data backup/restoration Fast link-up Fast logic
communication automatic setting
NZ2GF2S1-16D ● - - - ●*2
NZ2GF2B1N1-16D ● ● ● ● ●*2
NZ2GF2B1N-16D ● ● - - ●*2
NZ2GF2B1-32D NEW ● ● ● ● -
NZ2GFCE3-16D ● ● - - ●*2
DC input
NZ2GFCE3-16DE ● ● - - ●*2
NZ2GFCE3-32D ● - - - ●*2
NZ2GFCM1-16D ● ● - - ●*2
NZ2GFCM1-16DE ● ● - - ●*2
NZ2GFCF1-32D ● ● - ● ●*2
NZ2GF2S2-16A NEW ● ● ● ● ●*2
AC input
NZ2GF2B2-16A NEW ● ● ● ● ●*2
NZ2GF2S1-16T ● - - - ●*2
NZ2GF2S1-16TE ● - - - ●*2
NZ2GF2B1N1-16T ● ● ● ● ●*2
NZ2GF2B1N1-16TE ● ● ● ● ●*2
NZ2GF2B1N-16T ● ● - - ●*2
NZ2GF2B1N-16TE ● ● - - ●*2
Transistor NZ2GF2B1-32T NEW ● ● ● ● -
output NZ2GF2B1-32TE NEW ● ● ● ● -
NZ2GFCE3-16T ● ● - - ●*2
NZ2GFCE3-16TE ● ● - - ●*2
NZ2GFCE3-32T ● - - - ●*2
NZ2GFCM1-16T ● ● - - ●*2
NZ2GFCM1-16TE ● ● - - ●*2
NZ2GFCF1-32T ● ● - ● ●*2
NZ2GF2S2-16R NEW ● ● ● ● ●*2
Contact output
NZ2GF2B2-16R NEW ● ● ● ● ●*2
NZ2GF2S2-16S NEW ● ● ● ● ●*2
Triac output
NZ2GF2B2-16S NEW ● ● ● ● ●*2
NZ2GF2B1-32DT NEW ● ● ● ● ●
NZ2GF2B1-32DTE NEW ● ● ● ● ●
I/O combined
NZ2GFCE3-32DT ● - - - ●
NZ2GFCF1-32DT ● ● - ● ●
*1. For more information about modules and functions not stated in this list, please refer to the relevant module page.
*2. Available if the main module and the extension module are used together, one must be an input module and the other must be an output module.

29
Multiple input (voltage/current/temperature) module
•• Galvanic channel isolation and conversion speed is 40 ms/4 channels
•• Spring clamp terminal block does not require screw tightening, reducing wiring tasks
•• Supports variety of temperature sensors (12 types of thermocouple, 10 types of RDT)

Spring clamp terminal block type

NZ2GF2S-60MD4 NEW

NZ2GF2S-60MD4

Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GF2S-60MD4 Analog voltage/current/temperature input 4 ch - -

Analog input modules


•• The conversion speed of the analog input module is selectable from 100 μs/channel, 400 μs/channel,
and 1ms/channel*1
•• By combining with an extension module, precise control of the A/D conversion timing can be realized (Trigger

Features
Conversion Function)*2
*1. Conversion speed of NZ2GFCE-60ADV8 and NZ2GFCE-60ADI8 is 1ms/channel only.
*2. NZ2GFCE-60ADV8 and NZ2GFCE-60ADI8 do not support trigger conversion function.

Screw terminal block

Applications
NZ2GF2BN-60AD4
NZ2GF2BN-60AD4
Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GF2BN-60AD4 Analog voltage/current input 4 ch 1 ●

Products
Sensor connector (e-CON) type

NZ2GFCE-60ADV8 NEW
NZ2GFCE-60ADI8 NEW
NZ2GFCE-60ADV8
Options
Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GFCE-60ADV8 Analog voltage input 8 ch - -
NZ2GFCE-60ADI8 Analog current input 8 ch - -
Development tool
Product list

30
P r o d u c t s

Analog output modules


•• The conversion speed of NZ2GF2BN-60DA4 is 100 μs/channel, and NZ2GFCE-60DAV8 and NZ2GFCE-60DAI8
is 1ms/channel.

Screw terminal block

NZ2GF2BN-60DA4
NZ2GF2BN-60DA4
Model Output type Number of channels Max. extension modules Synchronized communication
NZ2GF2BN-60DA4 Analog voltage/current output 4 ch 1 ●

Sensor connector (e-CON) type

NZ2GFCE-60DAV8 NEW
NZ2GFCE-60DAI8 NEW
NZ2GFCE-60DAV8

Model Output type Number of channels Max. extension modules Synchronized communication
NZ2GFCE-60DAV8 Analog voltage output 8 ch - -
NZ2GFCE-60DAI8 Analog current output 8 ch - -

Temperature control modules


•• Operates at a sampling cycle of 250 ms/4 channels, with standard control (heating or cooling) or mixed-mode
(heating and cooling combined) supported
•• The Simultaneous temperature rise, Peak current suppression, and Self-tuning functions included
•• Input channel-isolation

Screw terminal block

NZ2GF2B-60TCTT4
NZ2GF2B-60TCRT4
NZ2GF2B-60TCTT4
Synchronized
Model Input type Output type Transistor output Number of channels Max. extension modules
communication
NZ2GF2B-60TCTT4 Thermocouple input Sink type 4 ch - -
NZ2GF2B-60TCRT4 RTD input Sink type 4 ch - -

High-speed counter module


•• Counting speed of 8 Mpps max (Duty ratio of the PWM output function can be set in 0.1 μs units enabling
precise output control)
•• The pulse measurement function with 100 ns measurement resolution enables highly-accurate pulse width
measurement

40-pin connector type

NZ2GFCF-D62PD2
NZ2GFCF-D62PD2

Synchronized
Model Input type Output type Transistor output Number of channels Max. extension modules
communication
Differential input
NZ2GFCF-D62PD2 Sink type 2 ch 1 ●
DC input

31
Extension modules
„Input/output
„ modules
•• Increases the number of available I/O points for the remote I/O, analog I/O, and high-speed counter modules
•• (Combined with) an analog input module the extension module receives external signals for A-D conversion
sampling timing control (sampling trigger adjustment)
•• (Combined with) a high-speed counter module the extension module enables the Cam switch function to provide
ON/OFF control at an accurate cycle
•• When a main input module, main output module or I/O combined module supporting CC-Link IE Field Network
synchronous communication function is connected, synchronous communication function can be used
•• When an extension output module is connected to a main input module, main output module or I/O combined
module, ON times integration function can be used

Spring clamp terminal block type

NZ2EX2S1-16D
NZ2EX2S1-16T
NZ2EX2S1-16TE NZ2EX2S1-16D

Features
Multiple modules
Model Input type DC input Input points Rated input voltage/current Wiring type
connectable
NZ2EX2S1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire -

Rated load voltage/ Multiple modules


Model Output type Transistor output Output points Wiring type
Max. load current connectable
NZ2EX2S1-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire -
NZ2EX2S1-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire -

Applications
Screw terminal block

NZ2EX2B1N-16D
NZ2EX2B1N-16T
NZ2EX2B1N-16TE

Products
NZ2EX2B1N-16D
Multiple modules
Model Input type DC input Input points Rated input voltage/current Wiring type
connectable
NZ2EX2B1N-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire ●

Rated load voltage/ Multiple modules


Model Output type Transistor output Output points Wiring type
Max. load current connectable
NZ2EX2B1N-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire ●
NZ2EX2B1N-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire ● Options

„Analog
„ input/output modules
•• Extends the number of analog points without any changes required to the network configuration
•• Conversion speed can be selected from 100 μs/channel, 400 μs/channel, and 1 ms/channel for the analog input
Development tool

module (Conversion speed switch function)


•• Conversion speed is 100 μs/channel for analog output module
•• Enables connection with analog I/O modules

Screw terminal block


Product list

NZ2EX2B-60AD4
NZ2EX2B-60DA4
NZ2EX2B-60AD4
Model Input/Output type Number of channels Multiple modules connectable
NZ2EX2B-60AD4 Analog voltage/current input 4 ch -
NZ2EX2B-60DA4 Analog voltage/current output 4 ch -

32
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable

◾◾CC-Link IE Field Network


Waterproof/dustproof type (IP67) remote modules*1
•• Complies with IP 67 rating. A control cabinet is no longer necessary, saving on
hardware cost and space
•• Push-to-lock connector reduces wiring tasks and eliminates maintenance as
retightening of screws*2
*1. General specifications and product guarantee conditions for co-branded products may vary from those of general MELSEC products. For more
information, please refer to the relevant product manuals or contact your local Mitsubishi Electric sales office/representative.
*2. Screw type connector is also supported.

NZ2GF12A42-16DT

Input modules
•• Response time can be set at 0 ms, 0.5 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms

Waterproof connector

NZ2GF12A4-16D NEW
NZ2GF12A4-16DE NEW
Model Input type DC input Input points Rated input voltage/current Wiring type
NZ2GF12A4-16D Positive common 16 points 24 V DC (7 mA) 2…4-wire
NZ2GF12A4-16DE Negative common 16 points 24 V DC (7 mA) 2…4-wire

Output modules
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function

Waterproof connector

NZ2GF12A2-16T NEW
NZ2GF12A2-16TE NEW
Rated load voltage/
Model Output type Transistor output Output points Wiring type
Max. load current
NZ2GF12A2-16T Sink type 16 points 12/24 V DC (2 A) 2-wire
NZ2GF12A2-16TE Source type 16 points 12/24 V DC (2 A) 2-wire

I/O combined modules


•• The I/O combined module controls both inputs and outputs all in one module
•• Response time can be set at 0 ms, 0.5 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms
•• High-speed I/O control is realized with the Fast logic function

Waterproof connector

NZ2GF12A42-16DT NEW
NZ2GF12A42-16DTE NEW
Input type Rated input voltage/ Output type Rated load voltage/
Model Input points Output points Wiring type
DC input current Transistor output Max. load current
NZ2GF12A42-16DT Positive common 8 points 24 V DC (7 mA) Sink type 8 points 12/24 V DC (2 A) 2…4-wire 2-wire
NZ2GF12A42-16DTE Negative common 8 points 24 V DC (7 mA) Source type 8 points 12/24 V DC (2 A) 2…4-wire 2-wire

33
◾◾CC-Link IE Field Network safety remote I/O modules

•• Remote I/O modules that support safety functions of CC-Link IE Field Network
•• Performs safety control when used together with the MELSEC iQ-R Series Safety CPU

Main safety input module


•• Input module with safety functions
•• Provides 16 safety input points (with double wiring)

Spring clamp terminal block type

NZ2GFSS2-32D

Features
NZ2GFSS2-32D
Extension module
Model Input type DC input Input points Rated input voltage/current Wiring type
compatibility
Single wiring: 32 points
NZ2GFSS2-32D Negative common 24 V DC (6 mA) 2-wire ●
Double wiring: 16 points

Applications
Extension safety output module
•• Extension output module with safety functions
•• Increases output points when combined with the main safety input module
•• Provides 4 safety output points (with double wiring)

Products
Spring clamp terminal block type

NZ2EXSS2-8TE

Options
NZ2EXSS2-8TE
Rated load voltage/
Model Output type Transistor output Output points Wiring type
Max. load current
Single wiring: 8 points
NZ2EXSS2-8TE Source + source type 24 V DC (0.5 A) 2-wire
Double wiring: 4 points
Development tool
Product list

34
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable

◾◾Network interface boards


„CC-Link
„ IE Field Network interface board
PCI Express® bus type

Q81BD-J71GF11-T2
PCI/PCI-X bus type

Q80BD-J71GF11-T2
•• These interface boards connect computers or controllers supporting PCI
Express®/PCI/PCI-X interface to CC-Link IE Field Network
•• Can be used as either a CC-Link IE Field Network master or local station*1
*1. The sub-master function and motion function are not supported.

„CC-Link
„ IE Control Network interface board
PCI Express® bus type

Q81BD-J71GP21-SX Q81BD-J71GP21S-SX
PCI/PCI-X bus type

Q80BD-J71GP21-SX Q80BD-J71GP21S-SX
•• These interface boards connect computers or controllers supporting PCI
Express®/PCI/PCI-X interface to CC-Link IE Control Network
•• Can be used as either a CC-Link IE Control Network master or local station
•• An interface board including external power supply input terminals
maintains communication in the event that the computer loses power

Q81BD-J71GP21S-SX/
Q80BD-J71GP21S-SX
External power supply I/P terminal type

„CC-Link
„ IE Field Network simple motion board
PCI Express® bus type

MR-EM340GF
•• Performs control of high-speed I/O and motion in one network, and
provides a suitable system layout with highly flexible wiring
•• Can be used as a CC-Link IE Field Network master station*2
•• Combined with a computer, the board performs advanced motion
control such as positioning, synchronous, and cam control with C++
programming (event-driven programs with interrupts are also supported)
*2. The local, sub-master, and safety communication functions are not supported.

35
Network interface board operation environment
Q81BD-J71GP21-SX/ Q80BD-J71GP21-SX/
Item Q81BD-J71GF11-T2 Q80BD-J71GF11-T2 MR-EM340GF
Q81BD-J71GP21S-SX Q80BD-J71GP21S-SX
Personal computer
Personal computer Windows® supported personal computer
CPU
System requirements of the operating system must be met
Required memory
PCI Express x1, x4,
®
PCI bus slot or PCI Express® x1, x2, PCI bus slot or PCI Express® x1, x2,
x8, x16 slot
Installation slot PCI-X slot x4, x8, x16 slot PCI-X slot x4, x8, x16 slot
(Standard/low profile,
(Half size) (Half size) (Half size) (Half size)
half size)
Compliant with PCI Compliant with PCI Compliant with PCI
Compliant with PCI Compliant with PCI
Bus specifications*1 Express® standard Express® standard Express® standard
standard Rev.2.2 standard Rev.2.2
Rev.1.1 Rev.1.1 Rev.2.0
Operating system (English Version)*2
Microsoft® Windows Server® 2008
●*3 ● −
Standard
Microsoft Windows Server 2008
●*3 ● −
Enterprise
Microsoft Windows Server 2008
●*3 ● −
Standard x64 Edition
Microsoft Windows Server 2008
●* 3
● −
Enterprise x64 Edition
Microsoft® Windows Server® 2008 R2
● ● −
Standard
Microsoft Windows Server 2008 R2
● ● −
Enterprise

Features
Microsoft Windows 7 Home
● ● −
Premium
Microsoft Windows 7 Professional ● ● ●
Microsoft® Windows® 7 Ultimate ● ● ●
Microsoft® Windows® 7 Enterprise ● ● ●
Microsoft® Windows Server® 2012
● ● −
Standard

Applications
Microsoft Windows Server 2012 R2
● ● −
Standard
Microsoft Windows 8
® ®
● ● −
Microsoft® Windows® 8 Pro ● ● −
Microsoft® Windows® 8 Enterprise ● ● −
Microsoft® Windows® 8.1 ● ● −
Microsoft® Windows® 8.1 Pro ● ● ●

Products
Microsoft® Windows® 8.1 Enterprise ● ● ●
Microsoft® Windows® 10 Home ● ● −
Microsoft® Windows® 10 Pro ● ● Coming soon!

Microsoft® Windows® 10 Enterprise ● ● Coming soon!

Microsoft® Windows® 10 Education ● ● −


Programming language (English Version)*2
Microsoft® Visual Studio® 2008
● ● −
Options
Visual Basic®*4
Microsoft® Visual Studio® 2010
● ● −
Visual Basic®
Microsoft® Visual Studio® 2012
● ● −
Visual Basic®
Microsoft® Visual Studio® 2013
● ● −
Visual Basic®
Microsoft Visual Studio 2015
® ®
● ● −
Visual Basic®
Development tool

Microsoft Visual Studio 2008


® ®
● ● −
Visual C++®
Microsoft® Visual Studio® 2010
● ● ●
Visual C++®
Microsoft® Visual Studio® 2012
● ● ●
Visual C++®
Microsoft® Visual Studio® 2013
● ● ●
Visual C++®
Product list

Microsoft® Visual Studio® 2015


● ● Coming soon!
Visual C++®
*1. For the details on bus specifications, please refer to the relevant product manual.
*2. For a combination of the operation system and the programming language, please refer to the relevant Microsoft® Knowledge Base.
*3. Service Pack 2 or later.
*4. 64-bit version user programs cannot be created using MELSEC data link library. Please use Visual Studio® 2010 or later.

For any other details on the operating environment, please refer to the relevant product manual.

36
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable

◾◾CC-Link IE Field Network Ethernet adapter module


NZ2GF-ETB
•• Connects Seamless Message Protocol (SLMP) compatible Ethernet devices
to CC-Link IE Field Network (enables a wide range of devices, such as vision
sensors and RFID, to be connected to the network)
•• Setting of station number, Ethernet options, and confirming error history is done
using a web browser
•• Supports 100 Mbps/1 Gbps transmission rates

◾◾CC-Link IE Field Network CC-Link bridge module


NZ2GF-CCB
•• Connects CC-Link Version 1 Remote I/O stations and Remote device stations to
CC-Link IE Field Network
•• Enables CC-Link parameters to be set with simple switch operations
•• Link devices assigned to this bridge module are assigned as the CC-Link remote
station’s link devices in the same station order

◾◾ CC-Link IE Field Network - AnyWireASLINK bridge module


NZ2AW1GFAL
•• Seamlessly connects AnyWireASLINK products to CC-Link IE Field Network
•• Supports max. wiring distance of 200 m with AnyWireASLINK, realizing flexible
wiring topology
•• Supports iQSS (iQ Sensor Solution), which enables parameter setup and
monitoring of slave devices connected to AnyWireASLINK

37
Realize cyclic communication
with software implementation only

CC-Link IE Field Network Basic


With recent trends of IoT*1, network connection of devices and equipment for small-scale systems are
becoming more mainstream. CC-Link IE Field Network Basic realizes easier network integration, as its cyclic
communications stack is software-based, without requiring a dedicated ASIC helping to reduce implementation
costs for device partners.
Mitsubishi Electric is launching CC-Link IE Field Network Basic compatible products to further leverage networking
on the production floor.

Plant-wide seamless communication


Utilizing standard Ethernet technology, TCP/IP protocol stack for communications (such as HTTP, FTP) is
supported. Based on SLMP*2, data flows transparently between the sensor level and the enterpise level across
multiple industry‑standard automation networks.
Seamless communication can be easily realized with CC-Link IE Field Network Basic, further improving
performance of the manufacturing enterprise.

Positioning within CC-Link IE Network


The Ethernet-based open network CC-Link IE is a
high-speed and large-capacity network integrating
Ethernet
distributed control, I/O control, safety control, and
Information
communication
motion control.
Seamless
CC-Link IE Field Network Basic, which is a part Controller distributed
control data
of CC‑Link IE Network, realizes easier network coordination
connection of Ethernet devices.
Transparent communications are achieved by utilizing
SLMP*2 that enables seamless connectivity within all
levels of manufacturing.

I/O control Safety control Motion control


*1. Internet of Things
*2. SeamLess Message Protocol

38
F e a t u r e s

Combining with TCP/IP communications


•• Configure more flexible system
•• Setup/monitor from enterprise level computer or tablet computer

◾◾Highly flexible system can be configured combining with TCP/IP


communications
The network operates on the standard Ethernet protocol stack, which can be used together with TCP/IP
communications. This feature allows CC-Link IE Field Network Basic compatible products and Ethernet compatible
products to be connected on the same Ethernet communications line, enabling a highly-flexible and low cost
system. By enabling cyclic communication control on standard Ethernet, parameter setting and status monitoring
can be done with peripheral devices (such as an enterprise level or tablet computer) connected via TCP/IP
communications.

Network

User applications
HTTP/ (Cyclic communication/transient communication/SLMP)
Application
FTP
software etc.

TCP/UDP
Protocol stack
IP
Communication driver Ethernet EIA-485

Wider range of connectable products


•• Connect third-party partner products on the same network

◾◾A wider range of CC-Link IE Field Network Basic-supported devices*1


CC-Link IE Field Network Basic realizes cyclic communication with software implementation only. System can be
easily configured using a standard managed switch and cables at a lower cost. Supported-products can be easily
developed and a wider range of CC-Link IE Field Network Basic-supported devices can be readily available.

Standard managed
switch

Cyclic communication between


master station Wi-Fi router
and slave stations
Ethernet

Remote I/O Robot GOT (HMI) Inverter Servo amplifier Solenoid valve*2 Label Bar-code In-line industrial
printer reader weighing scale

*1. Please refer to P.42 for compatible products.


*2. For further details regarding this product, please directly contact ‘CKD Corporation’, details can be found on their website at http://www.ckd.co.jp/english/glblinfo/global/
Note: Some images are for illustrative purposes only.

39
Small-scale network system configuration
•• Reduce the space for module installation
•• Reduce hardware cost

◾◾Network module is no longer necessary, saving on space and hardware cost


MELSEC programmable controller CPUs with an embedded Ethernet port can be used as a master station,
eliminating the need for an additional network module. The network can be configured with a minimum number of
modules reducing space and hardware cost.

Network module is no longer necessary, saving on space and hardware costs

Features
Simple setup and easy troubleshooting

Applications
•• Set up cyclic communication easily
•• Shorten the operating cycle when an error occurs

◾◾Commissioning by parameter setup and monitoring of operating status


Cyclic communication can be easily done just with parameter setting without requiring dedicated programs.

Products
Settings such as IP address can be easily done by automatically detecting slave devices using either the
GX Works3 or GX Works2 engineering tool. Maintenance is easier by being able to monitor the operating and
communication statuses of nodes connected on the network.

Options
Development tool

Parameter setting screen Diagnosis screen


Product list

40
A p p l i c a t i o n s

Solar panel production process

◾◾Easy data transmission to


IT system
Traceability data can be sent to enterprise
level devices directly from slave devices
other than master station

◾◾Easy connection with IT


sytem
Direct access to slave devices from
enterprise level devices

Direct access via standard


Ethernet

Ethernet

Standard managed
Master station switch

GOT (HMI) Inverter Servo amplifier* Bar-code reader Label printer

Slave station

*Image is for illustrative purposes only.

41
P r o d u c t s

◾◾CC-Link IE Field Network Basic embedded CPU modules

•• CPU module with CC-Link IE Field Network Basic embedded


•• The Ethernet port enables the module to operate as an Ethernet or CC-Link IE Field Network master station

„MELSEC
„ iQ-R Series „MELSEC
„ iQ-F Series
R□□CPU FX5U-□□□□/□□□
R□□ENCPU FX5UC-□□□□/□□□
•• 64 slave stations can be connected per network •• 6 slave stations can be connected per network

Features
R32CPU FX5U-32MR

Applications
„MELSEC-Q
„ Series „MELSEC-L
„ Series
Q□□UDVCPU L□□CPU(-P/-BT/-PBT)

•• 64 slave stations can be connected per network •• 16 slave stations can be connected per network

Products
Options

Q03UDVCPU L02CPU
Development tool
Product list

42
P r o d u c t s

◾◾CC-Link IE Field Network Basic compatible inverter


„Inverter
„ FREQROL-A800/F800/E700 Series
FR-A800-E FR-F800-E FR-E700-NE NEW

•• CC-Link IE Field Network Basic function embedded


•• CC-Link IE Field Network Basic realizes various inverter operations to
be monitored at a fast rate (multiple monitoring and parameter reading/
writing can also be executed simultaneously improving maintainability)
•• Seamless network environment enables monitoring and setup of
inverters from the IT system
•• Standard Ethernet is supported without installing a plug-in option,
realizing a low cost system easily
FR-A800-E

Model*1 Voltage class Capacity Structure/functionality


FR-A820-□K-E Three-phase 200 V 0.4…90 kW Standard model
FR-A840-□K-E Three-phase 400 V 0.4…280 kW Standard model
FR-A842-□K-E Three-phase 400 V 315…500 kW Separated converter type
FR-A846-□K-E Three-phase 400 V 0.4…132 kW IP55 compatible model
FR-F820-□K-E Three-phase 200 V 0.75…110 kW Standard model
FR-F840-□K-E Three-phase 400 V 0.75…315 kW Standard model
FR-F842-□K-E Three-phase 400 V 355…560 kW Separated converter type
FR-E720-□K-NE Three-phase 200 V 0.1…15 kW Standard model
FR-E740-□K-NE Three-phase 400 V 0.4…15 kW Standard model
FR-E720S-□K-NE Single-phase 200 V 0.1…2.2 kW Standard model
*1. “□” in the model name denotes rated output. For further details about model name, please refer to the “FREQROL-A800” catalogue (L (NA) 06075ENG) , “FREQROL-F800” catalogue (L (NA)
06085ENG) , “FREQROL-E700” catalogue (L (NA) 06051ENG).

◾◾CC-Link IE Field Network Basic compatible servo


„ Servo MELSERVO-JE Series
„AC

•• CC-Link IE Field Network Basic function embedded


•• Supports CiA402 drive profile
Profile position mode: pp
Profile velocity mode: pv
Profile torque mode: tq
Homing mode: hm
•• Pulse train command/analog voltage command are available

MR-JE-□C

Compatible servo motor


Model Voltage class Rated output*2
Rotary
MR-JE-□C 200 V 0.1…3 kW ●
*2. Servo amplifier of 2 kW and 3 kW will be available in the future.

43
◾◾CC-Link IE Field Network Basic compatible GOT (HMI)
„ GOT2000 Series
„HMI
GT27□□-□□□□ GT25□□□-□□□□ GT210□-□□BD
•• Cyclic communication is possible with CC-Link IE Field Network Basic
compatible devices via Ethernet interface of GOT (HMI)
•• TCP/IP communications are supported, enabling a highly-flexible system

Type*1 Screen size Panel color Power supply Multi-touch gesture functions
GT27
GT2715-XTBA 15”XGA Black 100…240 V AC ●
GT2715-XTBD 15”XGA Black 24 V DC ●
GT2712-ST□A 12.1”SVGA Black/white 100…240 V AC ●
GT2712-ST□D 12.1”SVGA Black/white 24 V DC ●
GT2710-STBA 10.4”SVGA Black 100…240 V AC ●
GT2710-STBD 10.4”SVGA Black 24 V DC ●
GT2710-VT□A 10.4”VGA Black/white 100…240 V AC ●
GT2710-VT□D 10.4”VGA Black/white 24 V DC ●
GT2708-STBA 8.4”SVGA Black 100…240 V AC ●

Features
GT2708-STBD 8.4”SVGA Black 24 V DC ●
GT2708-VTBA 8.4”VGA Black 100…240 V AC ●
GT2708-VTBD 8.4”VGA Black 24 V DC ●
GT2705-VTBD 5.7”VGA Black 24 V DC ●
GT25
GT2512-STBA 12.1”SVGA Black 100…240 V AC -
GT2512-STBD 12.1”SVGA Black 24 V DC -
GT2512F-STNA 12.1”SVGA - 100…240 V AC -
GT2512F-STND 12.1”SVGA - 24 V DC -

Applications
GT2510-VT□A 10.4”VGA Black/white 100…240 V AC -
GT2510-VT□D 10.4”VGA Black/white 24 V DC -
GT2510F-VTNA 10.4”VGA - 100…240 V AC -
GT2510F-VTND 10.4”VGA - 24 V DC -
GT2508-VT□A 8.4”VGA Black/white 100…240 V AC -
GT2508-VT□D 8.4”VGA Black/white 24 V DC -
GT2508F-VTNA 8.4”VGA - 100…240 V AC -
GT2508F-VTND 8.4”VGA - 24 V DC -
GT2510-WXT□D 10.1”WXGA Black/silver*2 24 V DC -

Products
GT2507-WT□D 7”WVGA Black/silver*2 24 V DC -
GT21
4.3”
GT2104-RTBD Black 24 V DC -
[480 x 272 dots]
4.5”
GT2104-PMBD Black 24 V DC -
[384 x 128 dots]
3.8”
GT2103-PMBD Black 24 V DC -
[320 x 128 dots]

Options
*1. “□” in the model name denotes panel color (B (black)/W (white)/S (silver)). For further details about model name, please refer to the “GOT 2000 Series consolidated catalogue (L(NA)08270ENG)”.
*2. The bottom part of the panel including the USB environmental protection cover is black.
Development tool
Product list

44
P r o d u c t s

◾◾FA sensor MELSENSOR


„Laser
„ displacement sensor
MH11CTMF-□□□
•• CC-Link IE Field Network Basic interface is included, enabling
connection without adding a network interface module to a PLC
•• Measured value, amount of incoming light, judgment output data can be
collected via network

MH11CTMF-N

45
◾◾CC-Link IE Field Network Basic Block type remote modules
•• CC-Link IE Field Network Basic slave station. These modules are useful when installation positions close to I/O
devices are required
•• Supports CC-Link IE Field Network Basic diagnostic function. Network error and I/O module fault can be
checked using the engineering software
•• Enables CC-Link parameters to be set with simple switch operations

Input modules
Screw terminal block

NZ2MFB1-32D NEW

NZ2MFB1-32D

Model Input type DC input Input points Rated input voltage/current Wiring type
NZ2MFB1-32D Positive common Negative common 32 points 24 V DC (6 mA) 1-wire

NZ2MFB2-16A

Features
NEW

Model Input type Input points Rated input voltage, frequency Rated input current Wiring type
8.2 mA (100 V AC, 60 Hz)
NZ2MFB2-16A AC input 16 points 100…120 V AC 2-wire
6.8 mA (100 V AC, 50 Hz)

Applications
Output modules
Screw terminal block

NZ2MFB1-32T NEW
NZ2MFB1-32TE1 NEW

Products
NZ2MFB1-32T

Rated load voltage/


Model Output type Transistor output Output points Wiring type
Max. load current
NZ2MFB1-32T Sink type 32 points 12/24 V DC (0.5 A) 1-wire
NZ2MFB1-32TE1 Source type 32 points 12/24 V DC (0.1 A) 1-wire

NZ2MFB2-16R NEW

Rated load voltage/ Options


Model Output type Output points Wiring type
Max. load current
NZ2MFB2-16R Contact output 16 points 24 V DC (2 A) 240 V AC (2 A) 2-wire

I/O combined modules


Development tool

Screw terminal block

NZ2MFB1-32DT NEW
NZ2MFB1-32DTE1 NEW NZ2MFB1-32DT
Product list

Input type Rated input voltage/ Output type Rated load voltage/
Model Input points Output points Wiring type
DC input current Transistor output Max. load current
NZ2MFB1-32DT Positive common 16 points 24 V DC (6 mA) Sink type 16 points 24 V DC (0.5 A) 1-wire
NZ2MFB1-32DTE1 Negative common 16 points 24 V DC (6 mA) Source type 16 points 24 V DC (0.1 A) 1-wire

46
CC-Link IE Control Network CC-Link IE Control Network
O p t i o n s CC-Link IE Field Network
twisted-pair cable optical cable

Options
◼◼Industrial switching hub
NZ2EHG-T8N
Powered by CONTEC

•• Supports the transmission speed of 10 Mbps/100 Mbps/1 Gbps


•• Equipped with Auto MDI/MDI-X and auto-negotiation functions
•• Saves up to 60% power consumption*1 by using the automatic power adjustment
function
•• Operates in ambient temperatures of 0 to 50°C, with the fan-less configuration
•• Compatible with DIN rail installation, enabling the hub to be installed in various
orientations
*1. For comparison, power consumption was measured when all 8 ports were used and not used.

NZ2EHG-T8N has a rated input supply voltage of 12 to 24 V DC.

This product was developed and manufactured by Contec Co. Ltd.


Please note that the specifications and conditions of guarantee differ from MELSEC Series products.

◼◼Managed CC-Link IE switch


NZ2MHG-T8F2
•• Supports the transmission speed of 10 Mbps/100 Mbps/1 Gbps
•• Connectable to CC-Link IE and Ethernet devices simultaneously
•• ERP- and LA- style redundant topologies between switches continue SFP
connector
communication at network failure including cable disconnection, by switching
network paths
•• With an SFP transceiver*2, long-distance optical cable, which is ideal for systems
requiring facility-to-facility landline communication is available
•• Supports VLAN and can manage multiple networks by one switch RJ45
connector
•• Supports SNMP, which enables monitoring of the entire network and easy
identification of faulty areas (system maintainability is improved with this feature)
NZ2MHG-T8F2 has the rated input voltage of 24 V DC.

„Using
„ along Ethernet network „ redundant topology
„ERP
One managed CC-Link IE switch is connectable to Redundant network paths between switches enable a
CC‑Link IE and Ethernet networks simultaneously system to be continuously operated in case of failure
without requiring special network configuration
Ethernet
GOT (HMI) RFID reader
Remote I/O Master station
module

Intelligent device
NZ2MHG-T8F2 Error
station Vision sensor When an error occurs, communications are re-established
Local station Ethernet module
via an alternative network line (within 10 ms)

„„SFP for long-distance communication „Multiple


„ networks with VLAN
With its long-distance data transmission feature, optical One switch can connect to multiple CC-Link IE
cables are ideal for facility-to-facility long‑distance networks
communications
Both ports support an SFP transceiver*2 VLAN 1 (Network 1) VLAN 2 (Network 2)
Optical cable

Master station 1 Master station 2

NZ2MHG-T8F2 NZ2MHG-T8F2
Multi-mode optical cable: up to 550 m NZ2MHG-T8F2
Single-mode optical cable: up to 5 km
*2. Either the optical port (OPT1/OPT2) or RJ45 port (P1/P2) can be used at a time.
Local station 1 Local station 2 Local station 3 Local station 4

47
Option

FA Partner Products

For details of Mitsubishi Electric System & Service Co., Ltd. products, please contact by sending an
Mitsubishi Electric System & Service e-mail to the following address.
<Sales office> FA PRODUCT DIVISION mail:[email protected]

◼◼Industrial switching hub


DT135TX
•• Compatible with 10 Mbps/100 Mbps/1000 Mbps transmission rates, 5 ports, and
the compact size unit with 12 V DC up to 24 V DC wide voltage-range
•• Passed the recommendation product examination of CC-Link Partner Association
•• Equipped with Auto MDI/MDI-X and auto-negotiation functions
•• Can receive 2 systematic power supplies when there is redundant power supply
•• Supports the line, star, line and star combination network topologies
•• Complies with UL/CE standards enabling export to Europe and North America

Features
◼◼Ethernet cable
SC-E5EW Series
•• 1000BASE-T Standard compliant. This Ethernet cable with double shield has an

Applications
outstanding shield performance
•• Available in lengths from 1 m to 100 m (in 1 m increments), for using in indoor
movable area available lengths are from 1 m to 45 m
Item SC-E5EW-S□M*1 SC-E5EW-S□M-MV*2 SC-E5EW-S□M-L*1
Cable type Category 5e or higher, (Double shielded/STP) Straight cable
Number of core
8 wires (4 twisted pairs)

Products
wires
Double shield Aluminum/polyester tape, Tin-plated annealed copper wire braid
Installation
Indoor Indoor movable Indoor/Outdoor
environment
Finished outside *1. "□" in the model name denotes a cable
Flame retardant PVC, 6.8 mm Flame retardant PVC, 6.5 mm LAP sheath, 10 mm
diameter length (up to 100 m in 1 meter increments).
Connector RJ-45 connector with shield, straight connection *2. "□" in the model name denotes a cable
Conforming IEEE802.3 1000BASE-T length (up to 45 m in 1 meter increments).
standards ANSI/TIA/EIA-568-B (Category 5e) ISO/IEC 11801

Options

◼◼Inline coupler
SPAD-RJ45S-E5E
•• 8 conductor RJ-45 female to female, shielded, fits standard type Keystone Wall
Plate
Development tool

•• Can be used in patch panels, wall jacks, or to extend cable lengths


Item Specifications
Adaptable connector RJ-45 connector with shield
Operable temperature −10°C…+60°C
IEEE 802.3 1000BASE-T
Conforming standards
ANSI/TIA/EIA-568-B (Category 5e) ISO/IEC 11801
Product list

48
CC-Link IE Control Network CC-Link IE Control Network
O p t i o n s CC-Link IE Field Network
twisted-pair cable optical cable

Mitsubishi Electric System & Service

◼◼Optical fiber cable


QG-AW QG-B QG-BU QG-C QG-DL QG-VCT
•• Cable types includes ones used inside panels, indoors, outdoors, and a
reinforced type for outdoor use, supporting versatile environments
•• The newly developed thin cable (for indoor and outdoor use) incorporates a cord
bundling structure, allowing safe use even in confined factory cable-conduits
•• The indoor and outdoor use cables are free of tension members, and have an
allowable tension equivalent to the reinforced type for outdoor use that allows
them to be pulled directly
•• The indoor use cable for movable using can be used for movable parts
•• The UL certified cable QG-BU for indoor use supports the high flame resistant
UL Listed (UL Type OFNR) compatible cable that has passed the UL1666 Riser
Flame Test
LCF connector
•• The outdoor use cable is waterproof, and can be used even in flooded or Duplex LC connector (IEC 61754-20)
temporarily submerged areas
•• A connector boot with improved bending characteristics reduces the possibility
of fiber breakage at the connector base

◼◼Standard accessories: Protective holder*1 (One protective holder is enclosed per cable.)
„Features
„
• Protects the cable connector base prevents breakage
• Maintains minimum bending radius
• Saves space in control panel (60 mm or less from the front of PLC to end of
protective holder)
*1. The protective holder is dedicated to the Mitsubishi Electric System Service Co., Ltd. LCF connector and is not available as a single unit. It
cannot be used with other LCF connector brands.

◼◼Splice adapter
SPAD-LCF-G50 SPAD-SCF-G50 SPAD-FC-G50
•• Extends optical cable (Splice connection)
•• Temporary connection for stations which may be extended later

„Applicable
„ connector
Type Model Specifications
Splice adapter for LCF connector, multimode 2 cores
Splice adapter for LCF Connector SPAD-LCF-G50
Connection loss: 0.3 dB (with master fiber)
Splice adapter for SC connector, multimode 2 cores
Splice adapter for SC Connector SPAD-SCF-G50
Connection loss: 0.3 dB (with master fiber)
Splice adapter for FC connector, multimode 1 core SPAD-LCF-G50
Splice adapter for FC Connector SPAD-FC-G50
Connection loss: 0.3 dB (with master fiber)

◼◼Connector insertion tool


SCT-SLM
•• Insert or remove connectors easily, even in tight spaces such as crowded control
panels

„Applicable
„ connector················································ LCF/LC/SC/MU connector

49
Mitsubishi Electric System & Service

◼◼Optical media converter


DMC-1000SL-DC (24 V DC)
•• When the station-to-station distance is greater than 550 m, two of these units
with optical cable can extend the total station-to-station distance up to 15 km
•• Equipped with the link pass through function, this converter supports the network
loop-back function in case of a cable disconnection

DMC-1000SL-DC

„Application
„ example „Specifications
„
DMC-1000SL-DC
Item
OPT1 port OPT2 port
IEEE802.3z Gigabit Ethernet IEEE802.3z Gigabit Ethernet
Conforming standard
(1000BASE-LX) (1000BASE-SX)
Transmission format Full duplex system
DMC-1000SL-DC DMC-1000SL-DC 1000BASE-SX compatible

Features
Optical 1000BASE-LX compatible multi-mode optical fiber cable*1
fiber single-mode optical fiber cable / (Band: 500 MHz · km or higher,
Multi-mode λ=850 nm)
Factory A optical fiber cable Factory B Duplex LC connector Duplex LC connector
(up to 550 m) Compatible Connector
cable (IEC 61754-20) (IEC 61754-20)
DMC-1000SL-DC DMC-1000SL-DC Polishing
method of PC, SPC, AdPC, UPC polish PC, SPC polish
connector
Method for
Crossing (A to B , B to A)
connection
Single-mode Single-mode Power supply

Applications
optical fiber cable optical fiber cable 20.4 V…26.4 V DC (Power supply terminal block)
specification
(up to 15 km) (up to 15 km) Standards UL, CE, FCC Part15 Class B, VCCI Class B
Series connection 4 (max.)
*1. For DMC-1000SL-DC: Optical fiber cable with a LC duplex connectors on both side
Factory C

◼◼Connection terminal

Products
SC-ECT-P3
•• Enables up to 3 stations to be added between existing stations
•• With stations that can easily be added or removed, the maintainability is
improved
•• Allows for expansion of the network without having to change the existing
cabling Options
•• Installable on the DIN rail or with screw brackets

„Communication
„ configuration example „Specifications
„
Item Specifications
1000 BASE-SX (MMF)-compatible optical fiber cable
Standard IEC60793-2-10 Types A1a.1 (50/125 μm multimode)
Applicable Transmission loss
Development tool

≤ 3.5dB/km (λ = 850 nm)


optical (max.)
fiber cable Transmission
≥ 500 MHz∙km (λ = 850 nm)
band (min.)
SC-ECT-P3*2
Model QG Series*4
*3 Duplex LC connector
Applicable Standard IEC 61754-20: Type LC connector
optical Connection loss ≤ 0.3 dB
connector Polished face PC polish
Model DLCF-G50-D2*4
Product list

Number of possible
Max. 3 units
connections
Connection distance Max. 150 m*5
*4. Parts provided by Mitsubishi Electric System & Service.
Additional stations *5. Cable length from SC-ECT-P3 to any other connection point.

*2. At least one unit should be connected to the connection terminal.


*3. The solid black lines represent cables with a maximum distance of 150 meters. If any station goes
down, the loop back function will still be operational.

The products listed here are manufactured by Mitsubishi Electric System & Service Co., Ltd. Please note that the specifications and guarantee conditions of the
products are different from the MELSEC Series products.

50
D e v e l o p m e n t t o o l

Development tool For further details, please refer to the


"Open Field Network CC‑Link Family
Compatible Product Development
Guidebook (L(NA)08052E)".

◾◾Network interface board driver development


The reference manual (for developing a driver for the
various operating systems) is provided to customers
who wish to use the network interface board with an
operating system other than Windows®. This reference CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code

manual contains sample C programs, aiming to save the


MADE IN JAPAN

C 2014 MITSUBISHI ELECTRIC CORPORATION

developer's programming time and cost.


ALL RIGHTS RESERVED

Reference manual

OS (non-Windows®)

Application Driver*1

*1. requires development by user


CC-Link IE Field Network/
CC-Link IE Control Network
interface board

Manual name Manual number


CC-Link IE Field Network Q80BD-J71GF11-T2/Q81BD-J71GF11-T2 Driver Development Reference Manual SH(NA)-081155ENG
CC-Link IE Control Network Q80BD-J71GP21-SX Driver Development Reference Manual SH(NA)-080819ENG

◾◾CC-Link IE Field Network source code development


•• The items shown on the right support development of
CC-Link IE Field Network master stations*2, without
requiring in-depth knowledge of the protocol
•• CP210 is a communication LSI dedicated to CC-Link CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code

IE Field Network master stations


MADE IN JAPAN

•• The source code CD-ROM contains C program


C 2014 MITSUBISHI ELECTRIC CORPORATION
ALL RIGHTS RESERVED

source codes and circuit examples (PDF), aiming to Source code Reference manual
save the developer's programming time and cost
*2. Does not support local station development.

Dedicated communication LSI

Type Model
Source code development CD-ROM SW1DNC-EFI210SRC
Type Model Packaging unit
Dedicated NZ2GACP210-60 60 pieces
communication LSI CP210 NZ2GACP210-300 300 pieces

Type Manual number Manual name


CC-Link IE Field Network
Reference manual SH(NA)-081455ENG Source Code Development Master Station Communication LSI CP210
Reference Manual

51
◾◾Communication LSI embedded with GbE-PHY CP520
•• The items shown on the right support development
of CC-Link IE Field Network slave stations, without
requiring in-depth knowledge of the protocol
•• CP520 supports development of CC-Link IE Field
Network intelligent device station and remote device
Communication LSI embedded with GbE-PHY
station
•• CP 520 is integrated communication LSI embedded
with CC-Link IE Field Network communication ASIC,
MPU, and GbE-PHY
•• The integrated communication LSI saves the CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code

MADE IN JAPAN

developer's programming time and cost related to C 2014 MITSUBISHI ELECTRIC CORPORATION
ALL RIGHTS RESERVED

MPU and GbE-PHY


Reference manual (CD-ROM)

Type Model Packaging unit


Communication LSI embedded with NZ2GACP520-60 60 pieces
GbE-PHY CP520 NZ2GACP520-300 300 pieces

Type Manual number Manual name


CC-Link IE Field Network

Features
Reference manual SH(NA)-081570ENG Intelligent Device Station Communication LSI
Embedded with GbE-PHY CP520 Reference Manual

◾◾Dedicated communication LSI, CP220


•• The items shown on the right support development

Applications
of CC-Link IE Field Network slave stations, without
requiring in-depth knowledge of the protocol
•• CP220 is a dedicated communication LSI for
intelligent device stations of CC-Link IE Field
Dedicated communication LSI
Network
•• The reference manual CD-ROM contains C program

Products
sample codes and circuit examples (PDF), aiming to
save the developer's programming time and cost
CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code

MADE IN JAPAN

C 2014 MITSUBISHI ELECTRIC CORPORATION


ALL RIGHTS RESERVED

Reference manual (CD-ROM)


Options
Type Model Packaging unit
Dedicated communication NZ2GACP220-60 60 pieces
LSI CP220 NZ2GACP220-300 300 pieces

Type Manual number Manual name


CC-Link IE Field Network Intelligent Device Station Communication LSI
Reference manual SH(NA)-081017ENG
CP220 Reference Manual
Development tool

For price and other details, please contact your local Mitsubishi Electric office or sales representative.
Membership (regular, executive, or board membership) to CC-Link Partner Association (CLPA) is required for purchasing the development tools for CC-Link IE Field
Network source code development and for the development incorporating the communication LSI embedded with GbE-PHY, CP520 and dedicated communication
LSI, CP220.
CC-Link Partner Association URL: http://www.cc-link.org
Product list

The license agreement must be signed prior to using the development tools for CC-Link IE Field Network source code development.
For hardware/software development, a referral to a partner is available on request.
Mitsubishi Electric Corporation Open System Center supports development using the development tools described in this section.

Open System Center, Mitsubishi Electric Corporation, E-mail: [email protected]


Nagoya Works

52
D e v e l o p m e n t t o o l

CC-Link IE Field Network/CC-Link IE Field Network Basic


Block type remote module
General specifications
Below are the environmental specifications where CC-Link IE Field Network/CC-Link IE Field Network Basic Block
type remote module is to be used. For the general specifications of other products, please refer to the catalog or
manual of the product. For the general specifications of double-branded products and the products manufactured
by other companies, please contact the manufacturer of the product.
Specifications
Item
Block type remote module Waterproof/dustproof type remote module
Operating ambient
0…55°C
temperature
Storage ambient
-25…75°C
temperature
Operating ambient
Complies with IP67*1
humidity 5…95%RH, non-condensing
Storage ambient humidity 5…95%RH, non-condensing
Compliant with JIS B 3502, IEC 61131-2
Frequency Acceleration Half amplitude Sweep count
5…8.4 Hz - 3.5 mm 10 times each in
Vibration resistance Under intermittent vibration
8.4…150 Hz 9.8 m/s2 - X, Y, Z directions
5…8.4 Hz - 1.75 mm
Under continuous vibration -
8.4…150 Hz 4.9 m/s2 -
Shock resistance Compliant with JIS B 3502, IEC 61131-2 (147 m/s2, 3 times in each of 3 directions X, Y, Z)
Operating ambient
No corrosive gases, no flammable gases, no excessive conductive dust
(humidity/temperature)
Operating altitude*2 0…2000 m*3
Installation location Inside a control panel Inside a control panel, outside a control panel
Overvoltage category*4 ≤2
Pollution level*5 ≤2
Equipment class Class 1 Class 3

Specifications
Item
Safety remote I/O module
Operating ambient
0…55°C
temperature
Storage ambient
-40…75°C
temperature
Operating ambient
humidity 5…95%RH, non-condensing
Storage ambient humidity
Compliant with JIS B 3502, IEC 61131-2
Frequency Acceleration Half amplitude Sweep count
5…8.4 Hz - 3.5 mm 10 times each in
Vibration resistance Under intermittent vibration
8.4…150 Hz 9.8 m/s2 - X, Y, Z directions
5…8.4 Hz - 1.75 mm
Under continuous vibration -
8.4…150 Hz 4.9 m/s 2
-
Shock resistance Compliant with JIS B 3502, IEC 61131-2 (147 m/s2, 3 times in each of 3 directions X, Y, Z)
Operating ambient
No corrosive gases*6, flammable gases, less conductive dust
(humidity/temperature)
Operating altitude*2 0…2000 m*3
Installation location Inside a control panel
Overvoltage category*4 ≤2
Pollution level*5 ≤2
Equipment class Class 3
*1. The module satisfies IP67 rating only when all waterproof plugs and caps are fitted and screws for a station setting switch cover are properly tightened.
*2. Do not use or store the programmable controller under pressure higher than the atmospheric pressure of altitude 0 m. Doing so may cause malfunction.
When using the programmable controller under pressure, please consult your local Mitsubishi Electric representative.
*3. When the programmable controller is used at altitude above 2000 m, the withstand voltage performance and the upper limit of the operating ambient temperature decrease. When using the
programmable controller under pressure, please contact your sales representative.
*4. This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises. Category
II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*5. This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected occasionally.
*6. Use the special coated products which comply with the IEC 60721-3-3 3C2 in the environment with the corrosive gases.
For details on the special coated products, please contact your sales representative.

53
CC-Link IE Field Network performance specifications
MELSEC iQ-R MELSEC iQ-R MELSEC-Q
Series Network interface Series
MELSEC iQ-R MELSEC-Q MELSEC-L Series
R04ENCPU board simple motion
Series Series Series simple motion
R08ENCPU Q80BD- module
Item master/local master/local master/local module
R16ENCPU J71GF11-T2, RD77GF4
module module module QD77GF4
R32ENCPU Q81BD- RD77GF8
RJ71GF11-T2 QJ71GF11-T2 LJ71GF11-T2 RD77GF16 QD77GF8
R120ENCPU J71GF11-T2
RD77GF32 QD77GF16
RJ71EN71
Communication speed 1 Gbps
Maximum stations per network 121 stations (1 master station. 120 slave stations)
Connection cable Ethernet cable (Category 5e or higher, double shielded/STP), straight cable
Line type: 12,000 m (When 1
Line type: 12,000 m (When 1 master station and 120 slave stations are connected) master station and 120 slave
Overall cable distance Star type: Depends on system configuration*1 stations are connected)
Ring type: 12,100 m (When 1 master station and 120 slave stations are connected) Star type: Depends on system
configuration*1
Maximum station-to-station distance 100 m
Maximum number of networks 239
Network topology Line type, star type*2, ring type Line type, star type*2
Communication method Token-pass
Maximum link points per network*3
8192 points,
RX 16384 points, 2K bytes
1K bytes
8192 points,
RY 16384 points, 2K bytes
1K bytes
1024 points,
RWr 8192 points, 16K bytes
2K bytes
1024 points,
RWw 8192 points, 16K bytes
2K bytes
Maximum link points per station*3
8192 points,
RX 16384 points, 2K bytes
1K bytes
8192 points,
RY 16384 points, 2K bytes
1K bytes
Master station
1024 points,
RWr 8192 points, 16K bytes
2K bytes
1024 points,
RWw 8192 points, 16K bytes
2K bytes
RX 2048 points, 256 bytes -
RY 2048 points, 256 bytes -
Local station* 4
RWr 1024 points, 2048 bytes 256 points, 512 bytes -
RWw 1024 points, 2048 bytes 256 points, 512 bytes -
RX 2048 points, 256 bytes
RY 2048 points, 256 bytes
Intelligent device 1024 points,
RWr 1024 points, 2048 bytes 256 points, 512 bytes
station 2048 bytes
1024 points,
RWw 1024 points, 2048 bytes 256 points, 512 bytes
2048 bytes
RX 128 points, 16 bytes
Remote device RY 128 points, 16 bytes
station RWr 64 points, 128 bytes
RWw 64 points, 128 bytes
Safety communications
Maximum number of safety 1814
- -
connections per network connections
Maximum number of safety 120
- -
connections per station connections
8 words
Maximum number of link points
- (input: 8 words, -
per safety connection
output: 8 words)
Transient transmission capacity
Transient transmission capacity 1920 bytes maximum
*1. A hub is required to use the star type wiring. Up to 20 hubs can be connected.
*2. Line and star types can also be mixed.
*3. Remote input RX: Bit data input from a slave station to the master station
Remote output RY: Bit data output from the master station to a slave station
Remote register RWr: 16-bit (word) unit data output from the master station to a slave station
Remote register RWw: 16-bit (word) unit data output from the master station to a slave station
* May partially differ for local stations
*4. Number of link points allocated by the master station. A local station can also use other link points to receive data from other stations.

For further details, please refer to the relevant product manuals.

54
CC-Link IE Control Network performance specifications
MELSEC iQ-R Series
R04ENCPU Network interface board
R08ENCPU MELSEC-Q Series Q80BD-J71GP21-SX
MELSEC iQ-R Series
Item R16ENCPU QJ71GP21-SX Q80BD-J71GP21S-SX
RJ71GP21-SX
R32ENCPU QJ71GP21S-SX Q81BD-J71GP21-SX
R120ENCPU Q81BD-J71GP21S-SX
RJ71EN71
Communication speed 1 Gbps
Maximum stations per
120 (1 control station, 119 normal stations)*1
network
Ethernet cable
(Category 5e or higher,
Connection cable Multi-mode optical cable
double shielded/STP),
straight cable
Laser class (JIS C 6802,
- Class 1 laser product
IEC 60825-1)
Line type: 11,900 m*2
Star type: Depends on system
Overall cable distance 66,000 m*2
configuration
Ring type: 12,000 m*2
Maximum station-to-
100 m 550 m
station distance
Maximum number of
239
networks
Maximum number of
32
groups
Network topology Line type, star type*3, ring type Duplex loop ring
Communication method Token-pass Token-ring
Maximum link points per network*4
LB 32768 points, 4K bytes 32768 points, 4K bytes*5 32768 points, 4K bytes
LW 131072 points, 256K bytes 131072 points, 256K bytes*6 131072 points, 256K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Communication speed*4 (Regular mode)
LB 16384 points, 2K bytes
LW 16384 points, 32K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Communication speed*4 (Extended mode*7)
LB 32768 points, 4K bytes
LW 131072 points, 256K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Transient transmission capacity
Transient transmission
1920 bytes maximum
capacity
*1. Under CC-Link IE Control Network, the number of connectable normal stations per network differs by the CPU module used in the control station.
For the details, please refer to the manual of the module used in the control station.
*2. When 120 stations are connected.
*3. Line and star types can also be mixed.
*4. Link relay LB: Bit data transmitted from stations in the network.
Link register LW: 16-bit (word) unit data transmitted from stations in the network.
Link input LX: Data input from a station to the I/O master in the same block.
Link output LY: Data output from the I/O master station to another station in the same block.
*5. 16384 points and 2K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU.
*6. 16384 points and 32K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU.
*7. To use the extended mode, all the stations must be compatible with the extended mode.

55
CC-Link IE Field Network Basic performance specifications
MELSEC iQ-R Series MELSEC-Q Series MELSEC-L Series MELSEC iQ-F Series
Item R◻CPU FX5U
Q◻UDVCPU L◻CPU
R◻ENCPU FX5UC
Communication speed 100 Mbps
Maximum stations per network*1 64 stations (16 stations × 4 groups) 16 stations 6 stations
Connection cable Ethernet standard compatible cable, Category 5e or higher (STP cable)
Maximum station-to-station
100 m (between a hub and node)*2
distance
Network topology Star type
Communication method UDP
Maximum link points per network*3
RX 4096 points 1024 points 384 points
RY 4096 points 1024 points 384 points
RWr 2048 points 512 points 192 points
RWw 2048 points 512 points 192 points
Maximum link points per station*3
RX 4096 points 1024 points 384 points
RY 4096 points 1024 points 384 points
Master station
RWr 2048 points 512 points 192 points
RWw 2048 points 512 points 192 points
RX 64 points; up to 256 points can be allocated according to the number of stations
RY 64 points; up to 256 points can be allocated according to the number of stations
Slave station*4
RWr 32 points; up to 128 points can be allocated according to the number of stations
RWw 32 points; up to 128 points can be allocated according to the number of stations
*1. Maximum number of slave stations controlled by the master station, depending on the number of allocated slave stations. The total number of allocated stations should not exceed the maximum number
of slave stations.
*2. The maximum distance between stations depends on the actual hub used. Please refer to the hub manufacturer’s specifications.
*3. Remote input RX: Bit data input from a slave station to the master station
Remote output RY: Bit data output from the master station to a slave station
Remote register RWr: 16-bit (word) unit data output from the master station to a slave station
Remote register RWw: 16-bit (word) unit data output from the master station to a slave station
*4. Number of link points allocated by the master station.

56
Cable specifications
CC-Link IE compatible twisted-pair cable*1
Item Specifications
Category 5e or higher, (double shielded/STP) straight cable
Twisted-pair cable Cables that conform to the following standards.
specifications Standard • IEEE802.3 (10000BASE-T)
• ANSI/TIA/EIA-568-B (Category 5e)
Connector
Standard RJ-45 connector with shield
specifications

CC-Link IE compatible optical cable*1


Item Specifications
1000BASE-SX (MMF) optical cable
Standard IEC 60793-2-10 Types A1a.1 (50/125 μm multimode)
Optical cable Transmission loss
(max.) ≤ 3.5 dB/km (λ = 850 nm)
specifications
Transmission band
≥ 500 MHz∙km (λ = 850 nm)
(min.)
Duplex LC connector
Connector Standard IEC 61754-20: Type LC connector
specifications Connection loss ≤ 0.3 dB
Polished face PC (Physical Contact) polishing
*1. For recommended cables and other information, contact the CC-Link Partner Association.

CC-Link IE Field Network Basic compatible twisted-pair cable


Item Specifications
Category 5e or higher, (STP) straight cable
Category 5 or 5e, (STP) cross cable
Twisted-pair
Cables that satisfy following standards
specifications
Standard • IEEE802.3 (100BASE-TX)
• ANSI/TIA/EIA-568-B (Category 5)
Connector specifications Standard RJ45

Network topologies*2
*2. CC-Link IE Field Network Basic supports star topology only.

Line topology (Twisted-pair cable) Star topology (Twisted-pair cable)

Switching HUB Switching HUB

Station-to-station
Station-to-station distance: distance: max.
max. 100 m 100 m

Overall cable distance


CC-Link IE Field Network: 12,000 m (with 121 stations)
CC-Link IE Control Network: 11,900 m (with 120 stations)

Ring topology (Twisted-pair cable) Ring topology (Dual-loop optical fiber)

Station-to-station distance: Station-to-station distance:


max. 100 m max. 550 m
Overall cable distance Overall cable distance
CC-Link IE Field Network: 12,100 m (with 121 stations) 66,000 m (with 120 stations)
CC-Link IE Control Network: 12,000 m (with 120 stations)

Master/Control station

Local/Normal station

57
Cyclic transmission
In cyclic transmission, data is transmitted periodically using link devices. Under CC-Link IE Field and Control
networks, some differences exist as described in this section.

◾◾CC-Link IE Field Network*1


One-to-one communication is possible between the master and slave stations. The status of link devices (RY,
RWw) within the master station are transmitted to an external device connected to a slave station. Likewise, the
status of external devices is transmitted to the master station link devices (RX, RWr) via the slave station.
In the case of local stations, the status of the master station link devices (RY, RWw) is relayed to all local station
link devices (RX, RWr) on the network. When an input from a slave or local station is executed, the slave station
link devices (RX, RWr) status and local station link devices (RY, RWw) status are stored in the master station link
device (RX, RWr), along with other local station link devices (RY, RWw). As a result, all local stations possess the
data of other slave stations, similar to the master station.
*1. The data is transmitted in the same method on CC-Link IE Field Network Basic. Note that communication is made between the master station and the slave stations only. No local stations are available
on the CC-Link IE Field Basic.

Station No. 0 Station No. 1 Station No. 2 Station No. 3 Station No. 4
CPU module Master station Slave station Slave station Local station Local station CPU module

Device RX, RWr RX, RWr RX, RWr RX, RWr Device
Station No. 1
Station No. 1 ❼ transmission Station No. 1 Station No. 1
area RX, RWr
Station No. 2
❽ Station No. 2 ❼ transmission Station No. 2 Station No. 2 ❹
Program area Program
scan scan
Link Station No. 3 ❼ Station No. 3 Station No. 3 Link
N
D

E
EN refresh refresh D
Station No. 4 ❼ Station No. 4 Station No. 4

Link
scan

Device RY, RWw RY, RWw RY, RWw RY, RWw Device

Station No. 1 ❸ Station No. 1 Station No. 1 Station No. 1


RY, RWw
❷ Station No. 2 ❸ Station No. 2 Station No. 2 Station No. 2 ❻
Program Program
scan Station No. 3 scan
Link Station No. 3 ❸ transmission Station No. 3 Link
N
D

EN refresh area refresh D


Station No. 4
Station No. 4 ❸ Station No. 4 transmission
area

M0 M0
Y ❶ : Area used to transmit data to other stations ❺ Y

Output from the master station


❶ In the master station, devices of the CPU module turn ON.
❷ In the master station, the status of the CPU module devices are stored in the link devices (RY, RWw) by link
refresh.
❸ The status of the master station link devices (RY, RWw) are then stored in the slave station link devices (RY,
RWw), and in the local station link devices (RX, RWr) by link scan.
❹ The status of the local station link devices (RX, RWr) are stored in the CPU module devices.

Input from the slave or local station


❺ In the local station, devices of the CPU module turn ON.
❻ In the local station, the status of the CPU module devices are stored in its own station link devices (RY, RWw)
transmission area.
❼ The status of the slave station link devices (RX, RWr), and the local station link devices (RY, RWw) are stored in
the master station link devices (RX, RWr) by link scan.
❽ The status of the master station link devices (RX, RWr) are stored in the CPU module devices by link refresh.

58
◾◾CC-Link IE Control Network
„
„Communications using link relays (LB) and link registers (LW)
This function allows each station to write data to its own send range of a link device (LB, LW) to send them to all
other stations on the network. The status data of the control station link devices (LB, LW) are stored in the link
devices (LB, LW) of each normal station. Likewise, the status of the normal station link devices (LB, LW) is stored
in link devices (LB, LW) of the control and other normal stations.

Station No. 1 Station No. 2 Station No. 3 Station No. 4


Link
CPU module Control station scan Normal station Normal station Normal station CPU module

Device ➋ LB, LW LB, LW LB, LW LB, LW ➍ Device


Station No. 1 ➌
transmission Station No. 1 Station No. 1 Station No. 1
area
Station No. 2
Station No. 2 transmission Station No. 2 Station No. 2
Program area Program
scan Station No. 3 scan
Station No. 3 Station No. 3 transmission Station No. 3 N
D

E
EN area D
Station No. 4
Station No. 4 Station No. 4 Station No. 4 transmission
area

Transmission request B
B ➊
: Area used to transmit data to other stations

❶ In the transmitting station, the CPU module devices turn ON.


❷ In the transmitting station, the CPU module devices status are stored in the link devices (LB, LW) of the
CC-Link IE Control Network supporting module by link refresh.
❸ The status of the link devices (LB, LW) in the transmitting station are sent to the link devices (LB, LW) of the
CC-Link IE Control Network supporting module in the receiving station by link scan.
❹ In the receiving station, the status of the link devices (LB, LW) are stored in the CPU module devices.

„
„Transmissions using link inputs (LX) and link outputs (LY)
An I/O master station, which controls link inputs (LX) and link outputs (LY), and another station make one to one
communication. LX is the input data transmitted between stations in a block, and LY is the output data transmitted
from the I/O master station in a block. The control or normal station can be an I/O master station, and up to two I/O
master stations (block 1 and block 2) can be used per network.
Control station Normal station Normal station Normal station
(Station No. 1) (Station No. 2) (Station No. 3) (Station No. 4)
Block 1
LX
I/O master
station
LY

LX
LY LX LY LY LX

Block 2
LX
I/O master
LY station
Normal station Normal station Normal station Normal station
(Station No. 5) (Station No. 6) (Station No. 7) (Station No. 8)

Transient transmission
This function allows communications with other stations when a request is made by a method such as a dedicated
instruction and engineering tool. Communications with different networks is also possible.

59
Extensive global support coverage
providing expert help whenever needed
■ Global FA centers

@5
@2 @1
@3@0
MITSUBISHI ELECTRIC
@4 @6 w CORPORATION !7
e y Nagoya Works
q
!6 !3 r
!0 t !8
!2
!4!5 u
!1
i
o

!9

China Indonesia Americas


q Shanghai FA Center o Indonesia FA Center !7 North America FA Center
MITSUBISHI ELECTRIC AUTOMATION (CHINA) PT. MITSUBISHI ELECTRIC INDONESIA MITSUBISHI ELECTRIC AUTOMATION, INC.
LTD. Shanghai FA Center Cikarang Office 500 Corporate Woods Parkway, Vernon Hills, IL 60061,
Mitsubishi Electric Automation Center, No.1386 Jl. Kenari Raya Blok G2-07A Delta Silicon 5, Lippo U.S.A.
Hongqiao Road, Shanghai, China Cikarang - Bekasi 17550, Indonesia Tel: +1-847-478-2469 / Fax: +1-847-478-2253
Tel: +86-21-2322-3030 / Fax: +86-21-2322-3000 Tel: +62-21-2961-7797 / Fax: +62-21-2961-7794
!8 Mexico FA Center
w Beijing FA Center MITSUBISHI ELECTRIC AUTOMATION, INC.
Vietnam
MITSUBISHI ELECTRIC AUTOMATION (CHINA) Mexico Branch
LTD. Beijin FA Center !0 Hanoi FA Center Mariano Escobedo #69, Col.Zona Industrial,
Unit 901, Office Tower 1, Henderson Centre, 18 MITSUBISHI ELECTRIC VIETNAM COMPANY Tlalnepantla Edo. Mexico, C.P.54030
Jianguomennei Avenue, Dongcheng District, Beijing, LIMITED Hanoi Branch Office Tel: +52-55-3067-7511
China
6th Floor, Detech Tower, 8 Ton That Thuyet Street, My
Tel: +86-10-6518-8830 / Fax: +86-10-6518-2938
Dinh2 Ward, Nam Tu Liem District, Hanoi, Vietnam Brazil
e Tianjin FA Center Tel: +84-4-3937-8075 / Fax: +84-4-3937-8076
MITSUBISHI ELECTRIC AUTOMATION (CHINA) !9 Brazil FA Center
!1 Ho Chi Minh FA Center MITSUBISHI ELECTRIC DO BRASIL COMÉRCIO E
LTD. Tianjin FA Center MITSUBISHI ELECTRIC VIETNAM COMPANY SERVIÇOS LTDA.
Room 2003 City Tower, No.35, Youyi Road, Hexi District, LIMITED
Tianjin, China Avenida Adelino Cardana, 293, 21 andar, Bethaville,
Tel: +86-22-2813-1015 / Fax: +86-22-2813-1017 Unit 01-04, 10th Floor, Vincom Center, 72 Le Thanh Ton Barueri SP, Brazil
Street, District 1, Ho Chi Minh City, Vietnam Tel: +55-11-4689-3000 / Fax: +55-11-4689-3016
r Guangzhou FA Center Tel: +84-8-3910-5945 / Fax: +84-8-3910-5947
MITSUBISHI ELECTRIC AUTOMATION (CHINA) Europe
LTD. Guangzhou FA Center India
Room 1609, North Tower, The Hub Center, No.1068,
@0 Europe FA Center
!2 India Pune FA Center MITSUBISHI ELECTRIC EUROPE B.V. Polish
Xingang East Road, Haizhu District, Guangzhou, China
Tel: +86-20-8923-6730 / Fax: +86-20-8923-6715 MITSUBISHI ELECTRIC INDIA PVT. LTD. Branch
Pune Branch
ul. Krakowska 50, 32-083 Balice, Poland
Taiwan Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - Tel: +48-12-347-65-81 / Fax: +48-12-630-47-01
411026, Maharashtra, India
t Taipei FA Center Tel: +91-20-2710-2000 / Fax: +91-20-2710-2100 @1 Germany FA Center
SETSUYO ENTERPRISE CO., LTD. MITSUBISHI ELECTRIC EUROPE B.V. German
!3 India Gurgaon FA Center
Branch
3F, No.105, Wugong 3rd Road, Wugu District, MITSUBISHI ELECTRIC INDIA PVT. LTD.
New Taipei City 24889, Taiwan Gurgaon Head Office Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Tel: +886-2-2299-9917 / Fax: +886-2-2299-9963 Tel: +49-2102-486-0 / Fax: +49-2102-486-1120
2nd Floor, Tower A & B, Cyber Greens, DLF Cyber City,
DLF Phase-3, Gurgaon-122002, Haryana, India @2 UK FA Center
Korea
Tel: +91-124-463-0300 / Fax: +91-124-463-0399 MITSUBISHI ELECTRIC EUROPE B.V. UK Branch
y Korea FA Center !4 India Bangalore FA Center Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K.
MITSUBISHI ELECTRIC AUTOMATION KOREA CO., MITSUBISHI ELECTRIC INDIA PVT. LTD. Tel: +44-1707-27-8780 / Fax: +44-1707-27-8695
LTD. Bangalore Branch @3 Czech Republic FA Center
8F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Prestige Emerald, 6th Floor, Municipal No.2, Madras MITSUBISHI ELECTRIC EUROPE B.V. Czech Branch
Gangseo-Gu, Seoul 07528, Korea Bank Road, Bangalore - 560001, Karnataka, India Pekarska 621/7, 155 00 Praha 5, Czech Republic
Tel: +82-2-3660-9632 / Fax: +82-2-3664-0475 Tel: +91-80-4020-1600 / Fax: +91-80-4020-1699 Tel: +420-255 719 200

Thailand !5 India Chennai FA Center @4 Italy FA Center


MITSUBISHI ELECTRIC INDIA PVT. LTD. MITSUBISHI ELECTRIC EUROPE B.V. Italian
u Thailand FA Center Chennai Branch Branch
MITSUBISHI ELECTRIC FACTORY AUTOMATION Citilights Corporate Centre No. 1, Vivekananda Road, Centro Direzionale Colleoni - Palazzo Sirio, Viale
(THAILAND) CO., LTD. Srinivasa Nagar, Chetpet, Chennai - 600031, Tamil Colleoni 7, 20864 Agrate Brianza (Milano), Italy
Nadu, India Tel: +39-039-60531 / Fax: +39-039-6053-312
12th Floor, SV.City Building, Office Tower 1, No. 896/19
Tel: +91-4445548772 / Fax: +91-4445548773
and 20 Rama 3 Road, Kwaeng Bangpongpang, Knet @5 Russia FA Center
Yannawa, Bangkok 10120, Thailand !6 India Ahmedabad FA Center MITSUBISHI ELECTRIC (RUSSIA) LLC ST.
Tel: +66-2682-6522~31 / Fax: +66-2682-6020 MITSUBISHI ELECTRIC INDIA PVT. LTD. Petersburg Branch
Ahmedabad Branch
ASEAN Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office
B/4, 3rd Floor, SAFAL Profitaire, Corporate Road, 720; 195027, St. Petersburg, Russia
i ASEAN FA Center Prahaladnagar, Satellite, Ahmedabad - 380015, Gujarat, Tel: +7-812-633-3497 / Fax: +7-812-633-3499
India
MITSUBISHI ELECTRIC ASIA PTE. LTD. Tel: +91-7965120063 @6 Turkey FA Center
307 Alexandra Road, Mitsubishi Electric Building, MITSUBISHI ELECTRIC TURKEY A.Ş Ümraniye
Singapore 159943 Branch
Tel: +65-6470-2480 / Fax: +65-6476-7439
Serifali Mahallesi Nutuk Sokak No:5, TR-34775
Umraniye / Istanbul, Turkey
Tel: +90-216-526-3990 / Fax: +90-216-526-3995

60
CC-Link Partner Association (CLPA) - Actively
promoting worldwide adoption of CC-Link networks
Proactively supporting CC-Link, from promotion to specification development
The CC-Link Partner Association (CLPA) was established to promote the worldwide adoption of the CC-Link open-field network. By
conducting promotional activities such as organizing trade shows and seminars, conducting conformance tests, and providing catalogs,
brochures and website information, CLPA activities are successfully increasing the number of CC-Link partner manufacturers and
CC-Link-compatible products. As such, CLPA is playing a major role in the globalization of CC-Link.

Seminar Trade show Conformance testing lab

Visit the CLPA website for the latest CC-Link information.


URL:www.cc-link.org

6F Ozone Front Bldg. 3-15-58 Ozone


Kita-ku, Nagoya 462-0825, JAPAN
TEL: +81-52-919-1588 FAX: +81-52-916-8655
E-mail:[email protected] CC-Link
Partner Association

Global influence of CC-Link continues to spread


CC-Link is supported globally by CLPA. With offices throughout the world, support for partner companies can be found locally.
Each regional CLPA office undertakes various support and promotional activities to further the influence of CC-Link/CC-Link IE in
that part of the world. For companies looking to increase their presence in their local area, CLPA is well placed to assist these
efforts through offices in all major regions.

CC-Link-Europe CT
(Germany)

CLPA-Korea CT
(Seoul)
CLPA-North America CT
(Vernon Hills, Illinois, USA)
CLPA-China CT CLPA Headquarters
(Shanghai) (Nagoya, Japan)
CT

CLPA-Americas NEW
(Mexico office)
CLPA-Taiwan (Tlalnepantla)
CLPA-Turkey (Taipei)
(Istanbul)

CC-Link
CLPA-India Promotion Center Thailand NEW
(Gurgaon) (Bangkok)

CT :Conformance Testing Lab CC-Link


Promotion Center ASEAN
(Singapore)

61
Factory Automation Global website
Mitsubishi Electric Factory Automation provides a mix of services to support its customers worldwide. A
consolidated global website is the main portal, offering a selection of support tools and a window to its local
Mitsubishi Electric sales and support network.

■ From here you can find:


• Overview of available factory automation products
• Library of downloadable literature
• Support tools such as online e-learning courses,
terminology dictionary, etc.
• Global sales and service network portal
• Latest news related to Mitsubishi Electric factory
automation

Mitsubishi Electric Factory Automation


Global website:
www.MitsubishiElectric.com/fa

Online e-learning
An extensive library of e-learning courses covering the factory automation product range has been prepared.
Courses from beginner to advanced levels of difficulty are available in various languages.

■ Beginner level
Designed for newcomers to Mitsubishi Electric
Factory Automation products gaining a background
of the fundamentals and an overview of various
products related to the course.

■ Basic to Advanced levels


These courses are designed to provide education
at all levels. Various different features are
explained with application examples providing
an easy and informative resource for in-house
company training.

62
Innovative next-generation, e-Manual
The e-Manual viewer is a next-generation digital manual offered by Mitsubishi Electric that consolidates all
manuals into an easy-to-use package with various useful features integrated into the viewer. The e-Manual is
modeled around a centralized database allowing multiple manuals to be cross-searched at once, further reducing
the time for reading individual product manuals when setting up a control system.

■ Key features include


• One-stop database containing all required manuals, with local file cache
• Included with GX Works3 engineering software
• Also available in tablet version
• Easily download manuals all at once
• Automatic update of manual versions
• Search information across multiple manuals
• Visual navigation from hardware diagram showing various specifications
• Customizable by adding user notes and bookmarks
• Directly port sample programs within manuals to GX Works3

■ MITSUBISHI ELECTRIC FA e-Manual (tablet version)

The e-Manual application is available on iOS and Android™ tablets.


e-Manual files are provided as in-app downloads.

iOS Android™
Version 8.1 or later Version 4.3/4.4/5.0

Supported versions
OS OS version Model
Apple iPad 2, iPad (3rd generation), iPad (4th generation), iPad Air, iPad Air 2,
iOS iOS 8.1 or later
iPad mini, iPad mini 2, iPad mini 3
Android™ Android™ 4.3/4.4/5.0 ASUS Nexus7™ (2013)*1
*1: When using a tablet not listed above, 7-inch (resolution of 1920×1200 dots (WUXGA)) or better is recommended.

63
P r o d u c t l i s t

Product list
Mitsubishi Electric Corporation …CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable

Type Model Outline

CC-Link IE embedded CPU module


MELSEC iQ-R Series CC-Link IE Field Network master/local station
R04ENCPU ● ● -
CC-Link IE Control Network control/normal station
MELSEC iQ-R Series CC-Link IE Field Network master/local station
R08ENCPU ● ● -
CC-Link IE Control Network control/normal station
MELSEC iQ-R Series CC-Link IE Field Network master/local station
R16ENCPU ● ● -
CC-Link IE Control Network control/normal station
MELSEC iQ-R Series CC-Link IE Field Network master/local station
R32ENCPU ● ● -
CC-Link IE Control Network control/normal station
MELSEC iQ-R Series CC-Link IE Field Network master/local station
R120ENCPU ● ● -
CC-Link IE Control Network control/normal station
Multi-network supporting Ethernet module
RJ71EN71 MELSEC iQ-R Series multi-network supported (Ethernet/CC-Link IE) ● ● -
Master/local module
RJ71GF11-T2 CC-Link IE Field Network master/local station for MELSEC iQ-R Series ● - -
QJ71GF11-T2 CC-Link IE Field Network master/local station for MELSEC-Q Series ● - -
LJ71GF11-T2 CC-Link IE Field Network master/local station for MELSEC-L Series ● - -
QS0J71GF11-T2 CC-Link IE Field Network safety master/local station for MELSEC-QS Series ● - -
Control network module
RJ71GP21-SX CC-Link IE Control Network control/normal station for MELSEC iQ-R Series - - ●
QJ71GP21-SX CC-Link IE Control Network control/normal station for MELSEC-Q Series - - ●

Features
CC-Link IE Control Network control/normal station (with the External power supply function)
QJ71GP21S-SX - - ●
for MELSEC-Q Series
Simple motion module
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF4 Up to 4-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF8 Up to 8-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -

Applications
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF16 Up to 16-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF32 NEW Up to 32-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF4 Up to 4-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -

Products
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF8 Up to 8-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF16 Up to 16-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
Head module

Options
RJ72GF15-T2 MELSEC iQ-R Series CC-Link IE Field Network compatible remote head module ● - -
LJ72GF15-T2 MELSEC-L Series CC-Link IE Field Network compatible head module (END cover enclosed) ● - -
Intelligent device station module
FX5-CCLIEF MELSEC iQ-F Series CC-Link IE Field Network intelligent device station module ● - -
AC Servo MELSERVO-J4 Series
MR-J4-GF(-RJ) CC-Link IE Field Network compatible servo amplifier ● - -
Inverter FREQROL-A800 Series
FR-A800-GF CC-Link IE Field Network compatible inverter ● - -
HMI GOT2000 Series
Development tool

Product package including a GOT (GT27□□-□□□□) and a CC-Link IE Field Network


GT27□□-□□□□-GF ● - -
communication unit (GT15-J71GF13-T2).
Product package including a GOT (GT25□□-□□□□) and a CC-Link IE Field Network
GT25□□-□□□□-GF ● - -
communication unit (GT15-J71GF13-T2)
GT15-J71GF13-T2 CC-Link IE Field Network communication unit, supported by GT27 and GT25 ● - -
GT15-J71GP23-SX CC-Link IE Control Network communication unit, supported by GT27 and GT25 - - ●
Ethernet adapter module
NZ2GF-ETB Compatible with Ethernet devices, transmission rate 100 Mbps/1 Gbps ● - -
Network bridge module
Product list

NZ2GF-CCB CC-Link IE Field Network - CC-Link bridge module ● - -


NZ2AW1GFAL CC-Link IE Field Network - AnyWireASLINK bridge module ● - -

64
P r o d u c t l i s t

Mitsubishi Electric Corporation …CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable

Type Model Outline

Block type remote module


16 points, 24 V DC, response time 0…70 ms,
NZ2GF2S1-16D ● - -
positive/negative common shared, spring clamp terminal block, 1-wire
16 points, 24 V DC, response time 0…70 ms,
NZ2GF2B1N1-16D ● - -
positive/negative common shared, screw terminal block, 1-wire, max. extension modules: 3
16 points, 24 V DC, response time 0…70 ms,
NZ2GF2B1N-16D ● - -
positive/negative common shared, screw terminal block, 1-wire
32 points, 24 V DC, response time 0…70 ms,
NZ2GF2B1-32D NEW ● - -
positive/negative common shared, screw terminal block, 1-wire
16 points, 24 V DC, response time 0…70 ms,
NZ2GFCE3-16D*1*2 ● - -
positive common (sink type), sensor connector (e-CON), 3-wire
DC input 16 points, 24 V DC, response time 0…70 ms,
NZ2GFCE3-16DE*1*2 ● - -
negative common (source type), sensor connector (e-CON), 3-wire
32 points, 24 V DC, response time 0…70 ms,
NZ2GFCE3-32D ● - -
positive common (sink type), sensor connector (e-CON), 3-wire
16 points, 24 V DC, response time 0…70 ms,
NZ2GFCM1-16D*1 ● - -
positive common (sink type), MIL connector (20 pin), 1-wire
16 points, 24 V DC, response time 0…70 ms,
NZ2GFCM1-16DE*1 ● - -
negative common (source type), MIL connector (20 pin), 1-wire
32 points, 24 V DC, response time 0…70 ms,
NZ2GFCF1-32D ● - -
positive/negative common shared, 40-pin connector, 1-wire
NZ2GF2S2-16A NEW 16 points, 100…120 V AC, 50/60 Hz, spring clamp terminal block, 2-wire ● - -
AC input
NZ2GF2B2-16A NEW 16 points, 100…120 V AC, 50/60 Hz, screw terminal block, 2-wire ● - -
NZ2GF2S1-16T 16 points, 12/24 V DC (0.5 A), sink type, spring clamp terminal block, 1-wire ● - -
NZ2GF2S1-16TE 16 points, 12/24 V DC (0.5 A), source type, spring clamp terminal block, 1-wire ● - -
16 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire
NZ2GF2B1N1-16T ● - -
max. extension modules: 3
16 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire
NZ2GF2B1N1-16TE ● - -
max. extension modules: 3
NZ2GF2B1N-16T 16 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire ● - -
Transistor NZ2GF2B1N-16TE 16 points, 12/24 V DC (0.5 A), source type, screw terminal block, 1-wire ● - -
output NZ2GF2B1-32T NEW 32 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire ● - -
NZ2GF2B1-32TE NEW 32 points, 12/24 V DC (0.5 A), source type, screw terminal block, 1-wire ● - -
NZ2GFCE3-16T*1*2 16 points, 12/24 V DC (0.5 A), sink type, sensor connector (e-CON), 3-wire ● - -
NZ2GFCE3-16TE*1*2 16 points, 12/24 V DC (0.5 A), source type, sensor connector (e-CON), 3-wire ● - -
NZ2GFCE3-32T 32 points, 12/24 V DC (0.5 A), sink type, sensor connector (e-CON), 3-wire ● - -
NZ2GFCM1-16T*1 16 points, 12/24 V DC (0.5 A), sink type, MIL connector (20 pin), 1-wire ● - -
NZ2GFCM1-16TE*1 16 points, 12/24 V DC (0.5 A), source type, MIL connector (20 pin), 1-wire ● - -
NZ2GFCF1-32T 32 points, 12/24 V DC (0.1 A), sink type, 40-pin connector, 1-wire ● - -
NZ2GF2S2-16R NEW 16 points, 24 V DC/240 V AC (2 A), spring clamp terminal block, 2-wire ● - -
Contact output
NZ2GF2B2-16R NEW 16 points, 24 V DC/240 V AC (2 A), screw terminal block, 2-wire ● - -
NZ2GF2S2-16S NEW 16 points, 100…240 V AC, 50/60 Hz (0.6 A), spring clamp terminal block, 2-wire ● - -
Triac output
NZ2GF2B2-16S NEW 16 points, 100…240 V AC, 50/60 Hz (0.6 A), screw terminal block, 2-wire ● - -
Input 16 points, 24 V DC, response time 0…70 ms, positive common
NZ2GF2B1-32DT NEW Output 16 points, 24 V DC (0.5 A), sink type ● - -
screw terminal block, 1-wire
Input 16 points, 24 V DC, response time 0…70 ms, negative common
NZ2GF2B1-32DTE NEW Output 16 points, 24 V DC (0.5 A), source type ● - -
I/O combined
screw terminal block, 1-wire
Input 16 points, 24 V DC, response time 0…70 ms, positive common (sink type)
NZ2GFCE3-32DT ● - -
Output 16 points, 12/24 V DC (0.5 A), sink type, sensor connector (e-CON), 3-wire
Input 16 points, 24 V DC, response time 0…70 ms, positive/negative common shared
NZ2GFCF1-32DT ● - -
Output 16 points, 12/24 V DC (0.1 A), sink type, 40-pin connector, 1-wire
Multiple input NZ2GF2S-60MD4 NEW 4 channels, analog voltage/current/temperature input, spring clamp terminal block ● - -
4 channels, -10…10 V DC, 0…20 mA DC; conversion speed, 100 μs/ch;
NZ2GF2BN-60AD4 ● - -
screw terminal block
8 channels, -10…10 V DC; conversion speed, 1 ms/ch;
Analog input NZ2GFCE-60ADV8 NEW ● - -
sensor connector (e-CON)
8 channels, 0…20 mA DC; conversion speed, 1 ms/ch;
NZ2GFCE-60ADI8 NEW ● - -
sensor connector (e-CON)
4 channels, -10…10 V DC, 0…20 mA DC; conversion speed, 100 μs/ch;
NZ2GF2BN-60DA4 ● - -
screw terminal block
8 channels, -10…10 V DC; conversion speed, 1 ms/ch;
Analog output NZ2GFCE-60DAV8 NEW ● - -
sensor connector (e-CON)
8 channels, 0…20 mA DC; conversion speed, 1 ms/ch;
NZ2GFCE-60DAI8 NEW ● - -
sensor connector (e-CON)
Temperature NZ2GF2B-60TCTT4 4 channels, thermocouple input, transistor output, screw terminal block ● - -
control NZ2GF2B-60TCRT4 4 channels, RTD input, transistor output, screw terminal block ● - -
2 channels
Differential input
Counting speed, 10 kpps/100 kpps/200 kpps/500 kpps/1 Mpps/2 Mpps/4 Mpps/8 Mpps;
High-speed
NZ2GFCF-D62PD2 count input signal, EIA Standard RS-422-A (Differential line driver) ● - -
counter
DC input
Counting speed, 10 kpps/100 kpps/200 kpps; count input signal, 5/24 V DC 4…8 mA;
coincidence output, transistor (sink type); 5…24 V DC (0.1 A); 40-pin connector

65
Product list
…CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
Mitsubishi Electric Corporation [ Legend ] DB : Double brand product*

Type Model Outline

Extension module for Block type remote module


16 points, 24 V DC, response time 0…70 ms, positive/negative common shared,
NZ2EX2S1-16D ● - -
spring clamp terminal block, 1-wire
16 points, 24 V DC, response time 0…70 ms, positive/negative common shared,
DC input NZ2EX2B1N-16D ● - -
screw terminal block, 1-wire, multiple modules connectable
16 points, 24 V DC, response time 0…70 ms, positive/negative common shared,
NZ2EX2B1-16D ● - -
screw terminal block, 1-wire
NZ2EX2S1-16T 16 points, 12/24 V DC (0.5 A), sink type, spring clamp terminal block, 1-wire ● - -
NZ2EX2S1-16TE 16 points, 12/24 V DC (0.5 A), source type, spring clamp terminal block, 1-wire ● - -
16 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire, multiple modules
NZ2EX2B1N-16T ● - -
connectable
Transistor 16 points, 12/24 V DC (0.5 A), source type, screw terminal block, 1-wire, multiple modules
NZ2EX2B1N-16TE ● - -
output connectable
16 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire
NZ2EX2B1-16T ● - -
Production will be discontinued in October 2017.
16 points, 12/24 V DC (0.5 A), source type, screw terminal block, 1-wire
NZ2EX2B1-16TE ● - -
Production will be discontinued in October 2017.
4 channels, Input: -10…10 V DC, 0…20 mA DC, Conversion speed: 100 μs/ch,
Analog input NZ2EX2B-60AD4 ● - -
screw terminal block
4 channels, Output: -10…10 V DC, 0…20 mA DC, Conversion speed: 100 μs/ch,

Features
Analog output NZ2EX2B-60DA4 ● - -
screw terminal block
Waterproof/dustproof type (IP67) remote module
NZ2GF12A4-16D 16 points, 24 V DC, response time 0…70 ms, positive common, waterproof connector,
● - -
DB NEW 2…4-wire
DC input
NZ2GF12A4-16DE 16 points, 24 V DC, response time 0…70 ms, negative common, waterproof connector,
● - -
DB NEW 2…4-wire
NZ2GF12A2-16T
16 points, 12/24 V DC (2 A), sink type, waterproof connector, 2-wire ● - -
Transistor DB NEW

Applications
output NZ2GF12A2-16TE
16 points, 12/24 V DC (2 A), source type, waterproof connector, 2-wire ● - -
DB NEW
Input 8 points, 24 V DC, response time 0…70 ms, positive common, 2…4-wire
NZ2GF12A42-16DT
Output 8 points, 12/24V DC (2 A), sink type, 2-wire ● - -
DB NEW
waterproof connector
I/O combined
Input 8 points, 24 V DC, response time 0…70 ms, negative common, 2…4-wire
NZ2GF12A42-16DTE
Output 8 points, 12/24 V DC (2 A), source type, 2-wire ● - -
DB NEW
waterproof connector
Safety remote I/O module

Products
Main safety 32 points with single wiring/16 points with double wiring, 24 V DC, response time 0.4 ms,
NZ2GFSS2-32D ● - -
input negative common, spring clamp terminal block, 2-wire
Extension 8 points with single wiring/4 points with double wiring, 24 V DC (0.5 A),
NZ2EXSS2-8TE ● - -
safety output source + source type, spring clamp terminal block, 2-wire
Network interface board
Q81BD-J71GF11-T2 CC-Link IE Field Network master/local station, compatible with PCI Express® bus ● - -
Q80BD-J71GF11-T2 CC-Link IE Field Network master/local station, compatible with PCI/PCI X bus ● - -
Q81BD-J71GP21-SX CC-Link IE Control Network control/normal station, compatible with PCI Express® bus - - ●
CC-Link IE Control Network control/normal station (with the External power supply function),
Q81BD-J71GP21S-SX - -
Options

compatible with PCI Express® bus
Q80BD-J71GP21-SX CC-Link IE Control Network control/normal station, compatible with PCI/PCI X bus - - ●
CC-Link IE Control Network control/normal station (with the External power supply function),
Q80BD-J71GP21S-SX - - ●
compatible with PCI/PCI X bus
PCI Express® bus type CC-Link IE Field Network simple motion board
MR-EM340GF max. control axis:16 linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
*1. A connector for the power supply and FG is required with e-CON and MIL connector type remote I/O module. Please refer to the option list on P.47 to check the type and model name.
Development tool

*2. A sensor connector is required with e-CON connector type remote I/O module. Please refer to the option list of Mitsubishi Electric System & Service Co., Ltd. products on P.48 to check the type and
model name.

For further details, please refer to the relevant product manuals.


Product list

66
P r o d u c t l i s t

CC-Link IE Field Network Basic compatible products


Type Model Outline
CC-Link IE Field Network Basic embedded CPU modules
R◻◻CPU MELSEC iQ-R Series CPU module master station
R◻◻ENCPU MELSEC iQ-R Series CC-Link IE embedded CPU module master station
Q◻◻UDVCPU MELSEC-Q Series High-speed Universal model QCPU module master station
L◻◻CPU (-P/-BT/-PBT) MELSEC-L Series CPU module master station
FX5U-◻◻◻◻/◻◻◻ MELSEC iQ-F Series FX5U CPU module master station
FX5UC-◻◻◻◻/◻◻◻ MELSEC iQ-F Series FX5UC CPU module master station
Inverters
FR-A800-E FREQROL-A800 Series Inverter slave station
FR-F800-E FREQROL-F800 Series Inverter slave station
FR-E700-NE NEW FREQROL-E700 Series Inverter slave station
AC servos
MR-JE-C MELSERVO-JE Series Servo slave station
HMI GOT2000 Series
GT27◻◻-◻◻◻◻ GT27 model slave station
GT25◻◻◻-◻◻◻◻ GT25 model slave station
GT210◻-◻◻BD GT21 model slave station
FA sensor MELSENSOR
MH11CTMF-◻◻◻ Laser displacement sensor MH11 controller slave station
Block type remote modules
DC input NZ2MFB1-32D NEW 32 points, 24 V DC, response time 0…70 ms, positive/negative common shared, screw terminal block, 1-wire
AC input NZ2MFB2-16A NEW 16 points, 100…120 V AC, 50/60 Hz, screw terminal block, 2-wire
Transistor NZ2MFB1-32T NEW 32 points, 12/24 V DC (0.5 A), sink type, screw terminal block, 1-wire
output NZ2MFB1-32TE1 NEW 32 points, 12/24 V DC (0.1 A), source type, screw terminal block, 1-wire
Contact output NZ2MFB2-16R NEW 16 points, 24 V DC/240 V AC (2 A), screw terminal block, 2-wire
Input 16 points, 24 V DC, response time 0…70 ms, positive common
NZ2MFB1-32DT NEW Output 16 points, 24 V DC (0.5 A), sink type
screw terminal block, 1-wire
I/O combined
Input 16 points, 24 V DC, response time 0…70 ms, negative common
NZ2MFB1-32DTE1 NEW Output 16 points, 24 V DC (0.1 A), source type
screw terminal block, 1-wire

67
Option list
…CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
Mitsubishi Electric Corporation [ Legend ] DB : Double brand product*

Type Model Outline

Industrial switching hub


NZ2EHG-T8N DB 10 Mbps/100 Mbps/1 Gbps, AUTO-MDIX, DIN rail, 8 ports ● ● -
Managed CC-Link IE switch
10 Mbps/100 Mbps/1 Gbps, DIN rail, 8 ports (including 2 fiber-optic compatible ports),
NZ2MHG-T8F2 ● ● -
CC-Link IE and Ethernet mix, ERP, LA, VLAN, and SNMP functions supported
Block type remote module/One touch connector plug for power supply and FG
Core wire size of applicable cable: 0.75 mm2 (0.66…0.98 mm2)(18 AWG),
A6CON-PW5P
0.16 mm or larger for strand diameter, insulating coating material PVC (heat resistant vinyl) ● - -
(35505-6080-A00 GF*1)
Outer diameter of applicable cable: ø2.2…3.0 mm, maximum rated current 7A*2, 10 pieces
Core wire size of applicable cable: 0.75 mm2 (0.66…0.98 mm2)(18 AWG),
A6CON-PW5P-SOD
0.16 mm or larger for strand diameter, insulating coating material PVC (heat resistant vinyl) ● - -
(35505-6180-A00 GF* )
1
Outer diameter of applicable cable: ø2.0…2.3 mm, maximum rated current: 7A*2, 10 pieces
Block type remote module/Online connector plug for power supply and FG
A6CON-PWJ5P
Online connector plug for the power supply and FG, 5 pieces ● - -
(35720-L200-A00 AK*1)
40-pin connector
A6CON1 Soldering connector (straight out type) ● - -
A6CON2 Crimp connector (straight out type) ● - -
A6CON3 Pressure-displacement connector (straight out type) ● - -
A6CON4 Soldering connector (both for straight out and 45-degree type) ● - -

Features
*1. Model name by the plug manufacturer 3M.
*2. The allowable current value of the cable connected must be observed.

Mitsubishi Electric System & Service Co., Ltd. …CC-Link IE Field Network …CC-Link IE Control Network twisted pair cable …CC-Link IE Control Network optical cable

Type Model Outline

Industrial switching hub


DT135TX 10 Mbps/100 Mbps/1000 Mbps, AUTO-MDIX, DIN rail, 5 ports ● ● -

Applications
Cable/accessory
SC-E5EW-S□M (Double shielded/STP) straight cable, Category 5e, for indoor use ● ● -
SC-E5EW-S□M-MV (Double shielded/STP) straight cable, Category 5e, for indoor movable part ● ● -
SC-E5EW-S□M-L (Double shielded/STP) straight cable, Category 5e, for indoor/outdoor use ● ● -
SPAD-RJ45S-E5E RJ-45 connector with shield ● ● -
QG-AW Optical fiber cable compatible with CC-Link IE Control Network (in the control panel) - - ●
QG-B Optical fiber cable compatible with CC-Link IE Control Network (indoor) - - ●
QG-BU UL optical fiber cable compatible with CC-Link IE Control Network (indoor) - - ●
QG-C Optical fiber cable compatible with CC-Link IE Control Network (outdoor) - - ●

Products
QG-DL Optical fiber cable compatible with CC-Link IE Control Network (outdoor, reinforced) - - ●
QG-VCT Optical fiber cable compatible with CC-Link IE Control Network (indoor, movable use) - - ●
SPAD-LCF-G50 Splice adapter for LCF connector, multimode 2 cores, connection loss 0.3 dB (with master fiber) - - ●
SPAD-SCF-G50 Splice adapter for SC connector, multimode 2 cores, connection loss 0.3 dB (with master fiber) - - ●
SPAD-FC-G50 Splice adapter for FC connector, multimode 1 core, connection loss 0.3 dB (with master fiber) - - ●
Connector insertion tool (applicable connector: LCF connector, LC connector, SC connector,
SCT-SLM - - ●
MU connector)
Optical media converter

Options
DMC-1000SL-DC Optical media converter compatible with CC-Link IE Control Network (24 V DC) - - ●
Connection terminal
SC-ECT-P3 Cable bundling device compatible with CC-Link IE Control Network - - ●
Sensor connector (e-CON) for Block type remote module
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
ECN-M014R ● - -
Outer diameter of applicable cable: ø0.8…1.0 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
ECN-M024Y ● - -
Outer diameter of applicable cable: ø1.0…1.2 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
Development tool

ECN-M034OR ● - -
Outer diameter of applicable cable: ø1.2…1.6 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M044GN ● - -
Outer diameter of applicable cable: ø1.0…1.2 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M054BL ● - -
Outer diameter of applicable cable: ø1.2…1.6 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M064GY ● - -
Outer diameter of applicable cable: ø1.6…2.0 mm, Maximum rated current: 2.0 A, 20 pieces
Product list

For details of Mitsubishi Electric System & Service Co., Ltd. products, please contact by sending an e-mail to the following address.
<Sales office> FA PRODUCT DIVISION mail:[email protected]

* General specifications and product guarantee conditions of jointly developed products are different from those of MELSEC products.
For further details, please refer to the product manuals, or contact your local Mitsubishi Electric sales representative.

68
Microsoft, Windows, Windows Vista, Windows Server, Visual Basic, Visual C++, and Visual Studio are registered trademarks of Microsoft Corporation in the United States and
other countries.
Ethernet is a trademark of Xerox Corporation.
MODBUS is a registered trademark of Schneider Electric USA, Inc.
All other company names and product names used in this document are trademarks or registered trademarks of their respective companies.

Precautions before use For s a fe us e

This publication explains the typical features and functions of the products herein •• To use the products given in this publication properly, always read the relevant
manuals before beginning operation.
and does not provide restrictions or other information related to usage and module •• The products have been manufactured as general-purpose parts for general
combinations. Before using the products, always read the product user manuals. industries, and are not designed or manufactured to be incorporated in a device or
system used in purposes related to human life.
Mitsubishi Electric will not be held liable for damage caused by factors found not to
•• Before using the products for special purposes such as nuclear power, electric
be the cause of Mitsubishi Electric; opportunity loss or lost profits caused by faults in power, aerospace, medicine or passenger-carrying vehicles, consult with Mitsubishi
Mitsubishi Electric products; damage, secondary damage, or accident compensation, Electric.
whether foreseeable or not, caused by special factors; damage to products other than •• The products have been manufactured under strict quality control. However, when
installing the products where major accidents or losses could occur if the products
Mitsubishi Electric products; or any other duties. fail, install appropriate backup or fail-safe functions in the system.

69
Automation solutions

YOUR SOLUTION PARTNER

Low voltage: MCCB, MCB, ACB

Medium voltage: VCB, VCC

Power monitoring, energy management

Mitsubishi Electric offers a wide range of automation equipment from PLCs and HMIs to
CNC and EDM machines.

Compact and Modular Controllers

A NAME TO TRUST This is why you can rely on


Mitsubishi Electric automation Inverters, Servos and Motors
Since its beginnings in 1870, some
45 companies use the Mitsubishi solution - because we know first
name, covering a spectrum of hand about the need for reliable,
finance, commerce and industry. efficient, easy-to-use automation and
control in our own factories.
Visualisation: HMIs
The Mitsubishi brand name is
recognized around the world as a As one of the world’s leading
symbol of premium quality. companies with a global turnover of
over 4 trillion Yen (over $40 billion),
Mitsubishi Electric Corporation is employing over 100,000 people,
Mitsubishi Electric has the resource Numerical Control (NC)
active in space development,
transportation, semi-conductors, and the commitment to deliver the
energy systems, communications ultimate in service and support as
and information processing, audio well as the best products.
visual equipment and home
Robots: SCARA, Articulated arm
electronics, building and energy
management and automation
systems, and has 237 factories and
laboratories worldwide in over 121
countries.
Processing machines: EDM, Lasers, IDS

Transformers, Air conditioning, Photovoltaic systems

* Not all products are available in all countries.

70
Country/Region Sales office Tel/Fax
USA MITSUBISHI ELECTRIC AUTOMATION, INC. Tel : +1-847-478-2100
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Fax : +1-847-478-2253
Mexico MITSUBISHI ELECTRIC AUTOMATION, INC. Mexico Branch Tel : +52-55-3067-7500
Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030
Brazil MITSUBISHI ELECTRIC DO BRASIL COMÉRCIO E SERVIÇOS LTDA. Tel : +55-11-4689-3000
Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Fax : +55-11-4689-3016
Germany MITSUBISHI ELECTRIC EUROPE B.V. German Branch Tel : +49-2102-486-0
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Fax : +49-2102-486-1120
UK MITSUBISHI ELECTRIC EUROPE B.V. UK Branch Tel : +44-1707-28-8780
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Fax : +44-1707-27-8695
Ireland MITSUBISHI ELECTRIC EUROPE B.V. Irish Branch Tel : +353-1-4198800
Westgate Business Park, Ballymount, Dublin 24, Ireland Fax : +353-1-4198890
Italy MITSUBISHI ELECTRIC EUROPE B.V. Italian Branch Tel : +39-039-60531
Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Fax : +39-039-6053-312
Spain MITSUBISHI ELECTRIC EUROPE, B.V. Spanish Branch Tel : +34-935-65-3131
Carretera de Rubí, 76-80-Apdo. 420, 08190 Sant Cugat del Vallés (Barcelona), Spain Fax : +34-935-89-1579
France MITSUBISHI ELECTRIC EUROPE B.V. French Branch Tel : +33-1-55-68-55-68
25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Fax : +33-1-55-68-57-57
Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech Branch Tel : +420-251-551-470
Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic Fax : +420-251-551-471
Poland MITSUBISHI ELECTRIC EUROPE B.V. Polish Branch Tel : +48-12-347-65-00
ul. Krakowska 50, 32-083 Balice, Poland Fax : +48-12-630-47-01
Sweden MITSUBISHI ELECTRIC EUROPE B.V. (Scandinavia) Tel : +46-8-625-10-00
Fjelievägen 8, SE-22736 Lund, Sweden Fax : +46-46-39-70-18
Russia MITSUBISHI ELECTRIC (RUSSIA) LLC St. Petersburg Branch Tel : +7-812-633-3497
Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 195027 St. Petersburg, Russia Fax : +7-812-633-3499
Turkey MITSUBISHI ELECTRIC TURKEY A.Ş Ümraniye Branch Tel : +90-216-526-3990
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye/Istanbul, Turkey Fax : +90-216-526-3995
UAE MITSUBISHI ELECTRIC EUROPE B.V. Dubai Branch Tel : +971-4-3724716
Dubai Silicon Oasis, P.O.BOX 341241, Dubai, U.A.E. Fax : +971-4-3724721
South Africa ADROIT TECHNOLOGIES Tel : +27-11-658-8100
20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Fax : +27-11-658-8101
China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD. Tel : +86-21-2322-3030
Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Fax : +86-21-2322-3000
Taiwan SETSUYO ENTERPRISE CO., LTD. Tel : +886-2-2299-2499
6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Fax : +886-2-2299-2509
Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD. Tel : +82-2-3660-9530
7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Fax : +82-2-3664-8372
Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD. Tel : +65-6473-2308
307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Fax : +65-6476-7439
Thailand MITSUBISHI ELECTRIC FACTORY AUTOMATION (THAILAND) CO., LTD. Tel : +66-2682-6522
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Fax : +66-2682-6020
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Vietnam MITSUBISHI ELECTRIC VIETNAM COMPANY LIMITED Hanoi Branch Tel : +84-4-3937-8075
6th Floor, Detech Tower, 8 Ton That Thuyet Street, My Dinh 2 Ward, Nam Tu Liem District, Hanoi, Vietnam Fax : +84-4-3937-8076
Indonesia PT. MITSUBISHI ELECTRIC INDONESIA Tel : +62-21-3192-6461
Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Fax : +62-21-3192-3942
India MITSUBISHI ELECTRIC INDIA PVT. LTD. Pune Branch Tel : +91-20-2710-2000
Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune-411026, Maharashtra, India Fax : +91-20-2710-2100
Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. Tel : +61-2-9684-7777
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245

Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO 14001 (standards for environmental
management systems) and ISO 9001 (standards for quality assurance management systems).

HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
www.MitsubishiElectric.com

New publication, effective May 2017.


L(NA)08111E-M 1705[IP] Specifications are subject to change without notice.

You might also like