01
iQ Platform
Features
ntr on
olle
r Engineering
Int
e Centralized engineering environment
Ne grate
tw d
ork
In
En tegr
gin ate
ee d
Applications
rin
g
Products
your manufacturing assets
Automation Controller Integrated Network Centralized Engineering
Improve productivity and product Best-in-class integrated Integrated engineering
quality network optimizing production environment with system level
capabilities features Options
1. High-speed system bus realizing 1. CC-Link IE supporting 1 Gbps 1. Automatic generation of system
improved system performance high-speed communication configuration
2. On-screen multi-touch control enabling 2. Seamless connectivity within all levels of 2. Share parameters across multiple
smooth GOT (HMI) operations manufacturing with SLMP engineering software via MELSOFT
Navigator
Development tool
02
on
ral Moti
Gene
ty
Safe
less
ing Seam
e sav
Spac
time
Real-
bit
g Giga
wirin
Less
rnet
Ethe
Ring
Line Star
ize
hron
Sync
03
Seamless connectivity within all levels of automation
The backbone of e-F@ctory, leveraging connectivity between the
shop floor and IT
• High-accuracy synchronization
enabling advanced motion control
• Simplified engineering and
execution using motion function
blocks /RS
AS
ting
tes
and
tion
ica
ppl
ea
ing past
kag der
Pac Sol
ce
pla
ly and
mb ick
sse Tp
al a SM
Fin
n
ove
low
Ref
on
ecti
insp
ing
lder
t-so
Pos
• Main line controller regulating all
network devices across production
• Ethernet-based open network
realizing seamless communication
(SLMP) across multiple networks
• Monitoring and setup of inverters
• On-machine direct connectivity to • Seamless integration of stand-alone throughout the network
sensors via remote devices machines to main plant-wide control
network
• Monitor various automation devices on
the network directly from the HMI
04
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable
to transfer large amounts of traceability data, a system MELSEC-Q MELSEC iQ-R MELSEC-L MELSEC-L
Series Series Series Series
capable of highly-detailed diagnostics can also be
realized.
Stable cyclic communication
◾◾Improve productivity
The 1 Gbps bandwidth is divided between deterministic Cyclic communication area (for control data)
(cyclic) and transient (message) communications. Deterministic
Cyclic communications, which is used for I/O control is
deterministic and its performance will not degrade even 1 Gbps
when large volumes of traceability and diagnostic data
are transferred via transient communication.
Transient (message) area (for information data)
Ethernet
Production
IT interface
Process acquired data,
Shop floor data
MES interface GOT (HMI)
sending result to shop
acquisition in real-time
module MES interface function embedded floor devices
05
Reduce installation cost with widely-available Ethernet components
•• Use widely-available components for overseas production sites
•• Procure system components for less
Ethernet-based network
Computer
Ethernet adapter
Master
station Wireless LAN adapter
Ethernet
switching HUB Label printer
1 Gbps
Vision sensor Ethernet devices compatible
with Seamless Message
Q06UDEHCPU
Protocol (SLMP)*1
Bar-code reader
Features
RFID controller
100 M/1 Gbps
Relay adapter
Applications
Ethernet switching HUB Ethernet cable connector Relay adapter
The Ethernet adapter unit realizes connection of SLMP*1 compatible Ethernet devices to a CC‑Link IE Field
Products
Network. Various devices can be connected such as vision sensors and RFID controllers.
*1. SLMP (Seamless Message Protocol): Is a client/server protocol that enables communications between Ethernet-ready and CC-Link IE compatible devices
Options
Relay adapter
Relay adapter
Easily configure
Extending the system additional stations
Development tool
06
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable
PW RUN
L ER
MODE D
LINK ERR.
P1Y0
1 2
3 Y4
LINK 5 6
X10
7 Y8
9 A
O/G 0 1 X1
B YC
TEST 2
D E
9 0 STATION F I/O
12 3 1 NO. PW
L11ER 4 8
10 5 7 +24V 2
P2 9 8 7 6 6
3
5 4
24G
LINK NZ2GF
2B1-16
(FG) T
1
3
5
7
9
11
2 13
4 15
6 17
8
10
12
14
16
18
PW RUN
L ER
MODE D
LINK ERR.
P1Y0
1 2
3 Y4
LINK 5 6
X10
7 Y8
9 A
O/G 0 1 X1
B YC
TEST D E
2 9 0 STATION F I/O
12 3 1 NO. PW
L11ER 4 8
10 5 7 +24V 2
P2 9 8 7 6 6
3
5 4
24G
NZ2GF
Star topology
LINK
2B1-16
(FG) T
1
3
5
7
9
11
2 13
4 15
6 17
8
10
12
14
16
18
Q06UDEHCPU
PW RUN
L ER PW RUN
L ER PW RUN
L ER
MODE D MODE D MODE D
LINK ERR. LINK ERR. LINK ERR.
P1Y0 P1Y0 P1Y0
1 2 1 2 1 2
3 Y4 3 Y4 3 Y4
LINK 5 6 LINK 5 6 LINK 5 6
X10
7 Y8 X10
7 Y8 X10
7 Y8
9 A 9 A 9 A
O/G 0 1 X1
B YC O/G 0 1 X1
B YC O/G 0 1 X1
B YC
TEST D E TEST D E TEST D E
2 9 0 STATION F I/O 2 9 0 STATION F I/O 2 9 0 STATION F I/O
12 3 1 NO. PW 12 3 1 NO. PW 12 3 1 NO. PW
L11ER 4 8 L11ER 4 8 L11ER 4 8
10 5 7 +24V 2 10 5 7 +24V 2 10 5 7 +24V 2
P2 9 8 7 6 6
3 P2 9 8 7 6 6
3 P2 9 8 7 6 6
3
5 4 24G 5 4 24G 5 4 24G
LINK NZ2GF LINK NZ2GF LINK NZ2GF
2B1-16 2B1-16 2B1-16
(FG) T (FG) T (FG) T
1 1 1
3 3 3
5 5 5
7 7 7
9 9 9
11 11 11
2 13 2 13 2 13
4 15 4 15 4 15
6 17 6 17 6 17
8 8 8
10 10 10
12 12 12
14 14 14
16 16 16
18 18 18
Line topology
Ring topology
Q06UDEHCPU
1
2
3
4
5
6
7
8
07
Synchronization performance for advanced motion control
•• Integrate networks of a motion control system in one network
•• Support advanced machines and systems
High-accuracy synchronization performance
GOT (HMI)
MR-J4-GF MR-J4-GF-RJ
Features
Synchronous
encoder
Mark
sensor
Output module
Applications
Printer
Products
Analog module
Options
Development tool
Product list
08
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable
09
Improve reliability with reduced single-point failure
•• Maintain communications during an error
Tracking cable
Features
Redundant network cable and communications module
ensure continuous operation in the event of an error
Applications
Products
Remote station Remote station
Options
Development tool
Product list
10
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable
NO. FUNCTION
1 AUTO PRM
ON 2 F LINK P1
3 F LINK P2
4 –
1234
NO. FUNCTION
1 AUTO PRM
ON 2 F LINK P1
3 F LINK P2
4 –
1234
*1. For applicable modules, please refer to CC-Link IE Field Network Block type remote modules on page 24.
Robot Computer
TCP/IP communication
Seamlessly connect to TCP/IP
devices via CC-Link IE Field Network.
11
Flexible I/O point extension
Extension function
Input signal
High-speed response
Input module
Extension input module
Output module Output signal
Extension output module
High-speed counter module Coating application
Extension analog input module Enable Boolean logic*2
Analog input module Extension analog output module between two inputs
Analog output module Extension input module
Photoelectric sensor
Extension output module
*2. Both AND logic and OR logic are supported as an output state.
*1. Extension modules which can connect multiple extension modules are available. For applicable
Features
modules, please refer to CC-Link IE Field Network block type remote modules on page 24.
Applications
Easy setup
Products
Example based on CC-Link IE Field Network
Registration of parameters
at Master station only
Options
Master
station Transfer Transfer
parameters
Development tool
Master station Station No. 1 Station No. 2 Station No. 3 Station No. 4
Product list
12
CC-Link IE Control Network CC-Link IE Control Network
F e a t u r e s CC-Link IE Field Network
twisted-pair cable optical cable
Engineering software
Intelligent device station No. 3 Local station No. 4 Local station No. 5
*1. MELSEC iQ-R Series is supported by GX Works3.
MELSEC-Q Series and MELSEC-L Series are supported by GX Works2.
*2. Referred to as the “Master station” for CC-Link IE Field network, and “Control station” for CC-Link IE Control network.
*3. Referred to as the “Sub-master station” for CC-Link IE Field network, and “Sub-control station” for CC-Link IE Control network.
13
Exceptionally fault-tolerant dual-loop optical cable
•• Reduce the noise influence
•• Maintain communications during an error
Highly-reliable loop topology
◾◾Fault-tolerant network
Dual-loop optical cables that provide noise-immunity to Electromagnetic Interference (EMI) and Radio Frequency
Interference (RFI) are used. These robust cables include a loop-back function which ensures data communication
even when there is a cable disconnection or the power supply is lost. In addition, an external power supply can
be connected to modules supporting this feature, ensuring communications even if connection to the controller or
computer is lost.
Loop-back function*1
Loop back
Faulty cable
Features
Loop-back function maintains communication
Applications
the communication line
Products
External power External power External power Communications maintained
supply supply supply even if between two faulty stations
*1. Loop-back function is supported when using ring topology with twisted-pair cable (both CC-Link IE Field and Control network).
Options
Development tool
Product list
14
A p p l i c a t i o n s
◾◾Seamless communication
Centralized system operation and
monitoring
◾◾Flexible wiring
Various equipment layouts by a
combination of star and bus topologies
◾◾CC-Link integration
Connectable with various products
supporting CC-Link
Ethernet
switching HUB
Star topology
simplifying
maintenance of
chamber wiring
CC-Link IE
- CC-Link Digital I/O Inverter Servo amplifier
bridge Analog I/O
module
RF power RF power
supply supply
15
Automotive paint shop (Safety system)
◾◾Safety communication
between different
processes
Safety control is coordinated between
different processes
◾◾Integration of non-safety
communications
Generic and safety control is performed on
one network
— Safety I/O —
Features
Control area 1 (Main) Control area 2 Control area n
Enabling switch
Emergency stop
switch
Applications
Light curtain
Door switch
Generic (non-safety) I/O Generic (non-safety) I/O Generic (non-safety) I/O
Products
Safety Safety Generic Generic
remote I/O remote I/O remote I/O remote I/O
Switch
Indicator light
Safety I/O Safety I/O Generic (non-safety) I/O Generic (non-safety) I/O
Options
p
Development tool
nt Sho ition
)
Pai ctro
-depos
oat (ele
E-C
g
Pa intin
Product list
ing
Cur
et
ern
Eth
16
A p p l i c a t i o n s
◾◾Large capacity
Large volume of recipe and traceability
data is transmitted together with cyclic
communication
◾◾Cyclic communication
Cyclic communication bandwidth is fixed
realizing deterministic control even when
transient communications are varied
Filling and
Cleaning Exposure Inspection Etching Resist stripping assembly
17
Steel production process
◾◾Large capacity
Large volume of recipe and traceability data is
transmitted together with cyclic communication
(1 Gbps)
◾◾Distributed control
Data is distributed between multiple controllers,
realizing high traceability
◾◾Highly-reliable
Realize highly-reliable system using redundant
CPUs, dual-loop optical network, and external
power supply
Features
1Gbps
Applications
Highly reliable communications
via dual-loop optical cable
Products
Tracking cable
Redundant system
enabling Options
high-reliability control
System-wide monitoring
from computer or HMI (GOT)
(acidic cleaning)
Product list
18
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable
QJ71GF11-T2
RJ71GF11-T2 LJ71GF11-T2
19
◾◾CC-Link IE Control Network modules
RJ71GP21-SX QJ71GP21-SX QJ71GP21S-SX
•• These modules can be used either as a CC-Link IE Control
Network control or normal station
•• Enables connection of an external power supply
(QJ71GP21S‑SX), which ensures communication even if the
controller power is lost
•• The station-based block data assurance feature ensures data
integrity between stations
Features
•• Perform advanced motion control such as synchronous, cam, and
positioning control including trajectory control
•• Can be used as a CC-Link IE Field Network master station*1
*1. RD77GF does not support the sub-master and safety communication functions.
QD77GF does not support the local, sub-master, and safety communication functions
Applications
RD77GF32 QD77GF16
Products
RJ72GF15-T2
•• A remote station can be realized through a combination of MELSEC
iQ-R Series I/O and intelligent function modules used together with this
module
•• Through its flexibility in system design, a remote station can be created
Options
based on the application size
•• Can access other stations on the network via USB port and perform
parameter setting and monitoring, saving on system configuration time
*2. For details of applicable modules, please refer to the relevant product manual.
RJ72GF15-T2
Development tool
20
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted pair cable optical cable
21
◾◾AC Servo MELSERVO-J4 Series
CC-Link
IE Field Network compatible servo amplifier
MR-J4-GF(-RJ)
•• CC-Link IE Field Network function embedded
•• Combined with the Simple Motion module, the servo amplifier can
perform synchronous and interpolation control, in addition to speed and
torque control
•• With a master module, the servo amplifier can perform positioning
operations just as easy as I/O operations, by using the point table
method (positioning operations are performed based on the point table
No. and start signal, without using a positioning module)
Features
◾◾Inverter FREQROL-A800 Series
CC-Link
IE Field Network compatible inverter
FR-A800-GF
Applications
•• CC-Link IE Field Network function embedded
•• High-speed communication of CC-Link IE Field Network realizes various
inverter operations to be monitored at a fast rate (multiple monitoring
and parameter reading/writing can also be executed simultaneously
improving maintainability)
•• Seamless network environment enables monitoring and setup of
Products
inverters from the IT system
22
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted pair cable optical cable
Model*1 Screen size Panel color Power supply Multi-touch gesture functions
GT2715-XTBA-GF 15"XGA Black 100 to 240 V AC ●
GT2715-XTBD-GF 15"XGA Black 24 V DC ●
GT2712-ST□A-GF 12.1"SVGA Black/white 100 to 240 V AC ●
GT2712-ST□D-GF 12.1"SVGA Black/white 24 V DC ●
GT2710-STBA-GF 10.4"SVGA Black 100 to 240 V AC ●
GT2710-STBD-GF 10.4"SVGA Black 24 V DC ●
GT2710-VT□A-GF 10.4"VGA Black/white 100 to 240 V AC ●
GT2710-VT□D-GF 10.4"VGA Black/white 24 V DC ●
GT2708-STBA-GF 8.4"SVGA Black 100 to 240 V AC ●
GT2708-STBD-GF 8.4"SVGA Black 24 V DC ●
GT2708-VTBA-GF 8.4"VGA Black 100 to 240 V AC ●
GT2708-VTBD-GF 8.4"VGA Black 24 V DC ●
GT2705-VTBD-GF 5.7"VGA Black 24 V DC ●
GT2512-STBA-GF 12.1"SVGA Black 100 to 240 V AC -
GT2512-STBD-GF 12.1"SVGA Black 24 V DC -
GT2510-VT□A-GF 10.4"VGA Black/white 100 to 240 V AC -
GT2510-VT□D-GF 10.4"VGA Black/white 24 V DC -
GT2508-VT□A-GF 8.4"VGA Black/white 100 to 240 V AC -
GT2508-VT□D-GF 8.4"VGA Black/white 24 V DC -
*1. "□" in the model name denotes panel color (B (black)/W (white)). For further details about model name, please refer to the "GOT 2000 Series consolidated catalogue (L(NA)08270ENG)".
CC-Link
IE Control Network communication unit
GT15-J71GP23-SX
•• HMI (GOT) communication unit for CC-Link IE Control Network
•• Integrates a HMI (GOT) as a normal station of CC-Link IE Control
Network
23
◾◾CC-Link IE Field Network Block type remote modules
•• These modules are useful when installation positions close to I/O devices are required
•• Connectable to extension modules, which increases the number of I/O points
•• Supports CC-Link IE Field Network synchronized communication (By synchronizing with the master station*1*2,
which supports synchronized communication, these modules perform highly-accurate synchronous operations
as slave stations.)
•• Modules*3 supporting fast link-up function quickly return when reconnected with the CC-Link IE Field Network
after disconnection
•• Modules*3 supporting automatic I/O parameter setting can be operated without setting parameters, thereby
reducing the start-up timing
*1. MELSEC iQ-R Series and simple motion module master stations support this feature.
*2. When using QD77GF16, this function cannot be used depending on the combination of the I/O module and software package used. For further details, please refer to the block type remote module
manual.
*3. For applicable modules, please refer to function list on P.29.
Features
•• High-speed I/O control is realized with the Fast logic function through a combination of an extension output
module
Applications
Spring clamp terminal block type
NZ2GF2S1-16D
NZ2GF2S1-16D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GF2S1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire 1
Products
NZ2GF2S2-16A NEW
Options
NZ2GF2B1N1-16D
NZ2GF2B1-32D NEW
Development tool
NZ2GF2B1-32D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GF2B1N1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire 3
NZ2GF2B1-32D Positive common Negative common 32 points 24 V DC (6 mA) 1-wire -
NZ2GF2B2-16A NEW
Product list
24
P r o d u c t s
NZ2GFCE3-16D
NZ2GFCE3-16DE
NZ2GFCE3-32D NZ2GFCE3-16D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCE3-16D Positive common 16 points 24 V DC (4 mA) 3-wire 1
NZ2GFCE3-16DE Negative common 16 points 24 V DC (4 mA) 3-wire 1
NZ2GFCE3-32D Positive common 32 points 24 V DC (4 mA) 3-wire 1
NZ2GFCM1-16D
NZ2GFCM1-16DE
NZ2GFCM1-16D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCM1-16D Positive common 16 points 24 V DC (4 mA) 1-wire 1
NZ2GFCM1-16DE Negative common 16 points 24 V DC (4 mA) 1-wire 1
NZ2GFCF1-32D
NZ2GFCF1-32D
Model Input type DC input Input points Rated input voltage/current Wiring type Max. extension modules
NZ2GFCF1-32D Positive common Negative common 32 points 24 V DC (4 mA) 1-wire 1
25
Main output modules
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function
•• High-speed I/O control is realized with the Fast logic function through a combination of an extension input
module
NZ2GF2S1-16T
NZ2GF2S1-16TE NZ2GF2S1-16T
NZ2GF2S2-16R NEW
Model Output type Output points Rated switching voltage/current Wiring type Max. extension modules
NZ2GF2S2-16R Contact output 16 points 24 V DC (2 A) 240 V AC (2 A) 2-wire 1
NZ2GF2S2-16S NEW
Features
Rated load voltage, frequency/
Model Output type Output points Wiring type Max. extension modules
Max. load curent
NZ2GF2S2-16S Triac output 16 points 100…240 V AC, 50/60 Hz (0.6 A) 2-wire 1
Applications
NZ2GF2B1N1-16T NZ2GF2B1-32T NEW
NZ2GF2B1N1-16TE NZ2GF2B1-32TE NEW NZ2GF2B1-32T
Rated load voltage/
Model Output type Transistor output Output points Wiring type Max. extension modules
Max. load current
NZ2GF2B1N1-16T Sink type 16 points 12/24 V DC (0.5 A) 1-wire 3
Products
NZ2GF2B1N1-16TE Source type 16 points 12/24 V DC (0.5 A) 1-wire 3
NZ2GF2B1-32T Sink type 32 points 12/24 V DC (0.5 A) 1-wire -
NZ2GF2B1-32TE Source type 32 points 12/24 V DC (0.5 A) 1-wire -
NZ2GF2B2-16R NEW
Model Output type Output points Rated switching voltage/current Wiring type Max. extension modules
NZ2GF2B2-16R Contact output 16 points 24 V DC (2 A) 240 V AC (2 A) 2-wire 1
Options
NZ2GF2B2-16S NEW
26
P r o d u c t s
NZ2GFCE3-16T
NZ2GFCE3-16TE
NZ2GFCE3-32T NZ2GFCE3-16T
NZ2GFCM1-16T
NZ2GFCM1-16TE
NZ2GFCM1-16T
NZ2GFCF1-32T
NZ2GFCF1-32T
27
Main I/O combined modules
•• The I/O combined module controls both inputs and outputs all in one module
•• Response time can be set at 0 ms, 0.2 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function
•• High-speed I/O control is realized with the Fast logic function
NZ2GF2B1-32DT NEW
NZ2GF2B1-32DTE NEW
NZ2GF2B1-32DT
Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
NZ2GF2B1-32DT Positive common 16 points 24 V DC (6 mA) Sink type 16 points 24 V DC (0.5 A) 1-wire -
NZ2GF2B1-32DTE Negative common 16 points 24 V DC (6 mA) Source type 16 points 24 V DC (0.5 A) 1-wire -
Features
NZ2GFCE3-32DT
NZ2GFCE3-32DT
Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
NZ2GFCE3-32DT Positive common 16 points 24 V DC (4 mA) Sink type 16 points 12/24 V DC (0.5 A) 3-wire 1
Applications
40-pin connector type
NZ2GFCF1-32DT
NZ2GFCF1-32DT
Products
Input type Rated input voltage/ Output type Output Rated load voltage/ Max. extension
Model Input points Wiring type
DC input current Transistor output points Max. load current modules
Positive common
NZ2GFCF1-32DT 16 points 24 V DC (4 mA) Sink type 16 points 12/24 V DC (0.1 A) 1-wire 1
Negative common
Options
Development tool
Product list
28
P r o d u c t s
29
Multiple input (voltage/current/temperature) module
•• Galvanic channel isolation and conversion speed is 40 ms/4 channels
•• Spring clamp terminal block does not require screw tightening, reducing wiring tasks
•• Supports variety of temperature sensors (12 types of thermocouple, 10 types of RDT)
NZ2GF2S-60MD4 NEW
NZ2GF2S-60MD4
Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GF2S-60MD4 Analog voltage/current/temperature input 4 ch - -
Features
Conversion Function)*2
*1. Conversion speed of NZ2GFCE-60ADV8 and NZ2GFCE-60ADI8 is 1ms/channel only.
*2. NZ2GFCE-60ADV8 and NZ2GFCE-60ADI8 do not support trigger conversion function.
Applications
NZ2GF2BN-60AD4
NZ2GF2BN-60AD4
Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GF2BN-60AD4 Analog voltage/current input 4 ch 1 ●
Products
Sensor connector (e-CON) type
NZ2GFCE-60ADV8 NEW
NZ2GFCE-60ADI8 NEW
NZ2GFCE-60ADV8
Options
Model Input type Number of channels Max. extension modules Synchronized communication
NZ2GFCE-60ADV8 Analog voltage input 8 ch - -
NZ2GFCE-60ADI8 Analog current input 8 ch - -
Development tool
Product list
30
P r o d u c t s
NZ2GF2BN-60DA4
NZ2GF2BN-60DA4
Model Output type Number of channels Max. extension modules Synchronized communication
NZ2GF2BN-60DA4 Analog voltage/current output 4 ch 1 ●
NZ2GFCE-60DAV8 NEW
NZ2GFCE-60DAI8 NEW
NZ2GFCE-60DAV8
Model Output type Number of channels Max. extension modules Synchronized communication
NZ2GFCE-60DAV8 Analog voltage output 8 ch - -
NZ2GFCE-60DAI8 Analog current output 8 ch - -
NZ2GF2B-60TCTT4
NZ2GF2B-60TCRT4
NZ2GF2B-60TCTT4
Synchronized
Model Input type Output type Transistor output Number of channels Max. extension modules
communication
NZ2GF2B-60TCTT4 Thermocouple input Sink type 4 ch - -
NZ2GF2B-60TCRT4 RTD input Sink type 4 ch - -
NZ2GFCF-D62PD2
NZ2GFCF-D62PD2
Synchronized
Model Input type Output type Transistor output Number of channels Max. extension modules
communication
Differential input
NZ2GFCF-D62PD2 Sink type 2 ch 1 ●
DC input
31
Extension modules
Input/output
modules
•• Increases the number of available I/O points for the remote I/O, analog I/O, and high-speed counter modules
•• (Combined with) an analog input module the extension module receives external signals for A-D conversion
sampling timing control (sampling trigger adjustment)
•• (Combined with) a high-speed counter module the extension module enables the Cam switch function to provide
ON/OFF control at an accurate cycle
•• When a main input module, main output module or I/O combined module supporting CC-Link IE Field Network
synchronous communication function is connected, synchronous communication function can be used
•• When an extension output module is connected to a main input module, main output module or I/O combined
module, ON times integration function can be used
NZ2EX2S1-16D
NZ2EX2S1-16T
NZ2EX2S1-16TE NZ2EX2S1-16D
Features
Multiple modules
Model Input type DC input Input points Rated input voltage/current Wiring type
connectable
NZ2EX2S1-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire -
Applications
Screw terminal block
NZ2EX2B1N-16D
NZ2EX2B1N-16T
NZ2EX2B1N-16TE
Products
NZ2EX2B1N-16D
Multiple modules
Model Input type DC input Input points Rated input voltage/current Wiring type
connectable
NZ2EX2B1N-16D Positive common Negative common 16 points 24 V DC (6 mA) 1-wire ●
Analog
input/output modules
•• Extends the number of analog points without any changes required to the network configuration
•• Conversion speed can be selected from 100 μs/channel, 400 μs/channel, and 1 ms/channel for the analog input
Development tool
NZ2EX2B-60AD4
NZ2EX2B-60DA4
NZ2EX2B-60AD4
Model Input/Output type Number of channels Multiple modules connectable
NZ2EX2B-60AD4 Analog voltage/current input 4 ch -
NZ2EX2B-60DA4 Analog voltage/current output 4 ch -
32
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable
NZ2GF12A42-16DT
Input modules
•• Response time can be set at 0 ms, 0.5 ms, 1 ms, 1.5 ms, 5 ms, 10 ms, 20 ms and 70 ms
Waterproof connector
NZ2GF12A4-16D NEW
NZ2GF12A4-16DE NEW
Model Input type DC input Input points Rated input voltage/current Wiring type
NZ2GF12A4-16D Positive common 16 points 24 V DC (7 mA) 2…4-wire
NZ2GF12A4-16DE Negative common 16 points 24 V DC (7 mA) 2…4-wire
Output modules
•• Cumulative contact ON times of a module can be easily confirmed with the ON times integration function
Waterproof connector
NZ2GF12A2-16T NEW
NZ2GF12A2-16TE NEW
Rated load voltage/
Model Output type Transistor output Output points Wiring type
Max. load current
NZ2GF12A2-16T Sink type 16 points 12/24 V DC (2 A) 2-wire
NZ2GF12A2-16TE Source type 16 points 12/24 V DC (2 A) 2-wire
Waterproof connector
NZ2GF12A42-16DT NEW
NZ2GF12A42-16DTE NEW
Input type Rated input voltage/ Output type Rated load voltage/
Model Input points Output points Wiring type
DC input current Transistor output Max. load current
NZ2GF12A42-16DT Positive common 8 points 24 V DC (7 mA) Sink type 8 points 12/24 V DC (2 A) 2…4-wire 2-wire
NZ2GF12A42-16DTE Negative common 8 points 24 V DC (7 mA) Source type 8 points 12/24 V DC (2 A) 2…4-wire 2-wire
33
◾◾CC-Link IE Field Network safety remote I/O modules
•• Remote I/O modules that support safety functions of CC-Link IE Field Network
•• Performs safety control when used together with the MELSEC iQ-R Series Safety CPU
NZ2GFSS2-32D
Features
NZ2GFSS2-32D
Extension module
Model Input type DC input Input points Rated input voltage/current Wiring type
compatibility
Single wiring: 32 points
NZ2GFSS2-32D Negative common 24 V DC (6 mA) 2-wire ●
Double wiring: 16 points
Applications
Extension safety output module
•• Extension output module with safety functions
•• Increases output points when combined with the main safety input module
•• Provides 4 safety output points (with double wiring)
Products
Spring clamp terminal block type
NZ2EXSS2-8TE
Options
NZ2EXSS2-8TE
Rated load voltage/
Model Output type Transistor output Output points Wiring type
Max. load current
Single wiring: 8 points
NZ2EXSS2-8TE Source + source type 24 V DC (0.5 A) 2-wire
Double wiring: 4 points
Development tool
Product list
34
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable
Q81BD-J71GF11-T2
PCI/PCI-X bus type
Q80BD-J71GF11-T2
•• These interface boards connect computers or controllers supporting PCI
Express®/PCI/PCI-X interface to CC-Link IE Field Network
•• Can be used as either a CC-Link IE Field Network master or local station*1
*1. The sub-master function and motion function are not supported.
CC-Link
IE Control Network interface board
PCI Express® bus type
Q81BD-J71GP21-SX Q81BD-J71GP21S-SX
PCI/PCI-X bus type
Q80BD-J71GP21-SX Q80BD-J71GP21S-SX
•• These interface boards connect computers or controllers supporting PCI
Express®/PCI/PCI-X interface to CC-Link IE Control Network
•• Can be used as either a CC-Link IE Control Network master or local station
•• An interface board including external power supply input terminals
maintains communication in the event that the computer loses power
Q81BD-J71GP21S-SX/
Q80BD-J71GP21S-SX
External power supply I/P terminal type
CC-Link
IE Field Network simple motion board
PCI Express® bus type
MR-EM340GF
•• Performs control of high-speed I/O and motion in one network, and
provides a suitable system layout with highly flexible wiring
•• Can be used as a CC-Link IE Field Network master station*2
•• Combined with a computer, the board performs advanced motion
control such as positioning, synchronous, and cam control with C++
programming (event-driven programs with interrupts are also supported)
*2. The local, sub-master, and safety communication functions are not supported.
35
Network interface board operation environment
Q81BD-J71GP21-SX/ Q80BD-J71GP21-SX/
Item Q81BD-J71GF11-T2 Q80BD-J71GF11-T2 MR-EM340GF
Q81BD-J71GP21S-SX Q80BD-J71GP21S-SX
Personal computer
Personal computer Windows® supported personal computer
CPU
System requirements of the operating system must be met
Required memory
PCI Express x1, x4,
®
PCI bus slot or PCI Express® x1, x2, PCI bus slot or PCI Express® x1, x2,
x8, x16 slot
Installation slot PCI-X slot x4, x8, x16 slot PCI-X slot x4, x8, x16 slot
(Standard/low profile,
(Half size) (Half size) (Half size) (Half size)
half size)
Compliant with PCI Compliant with PCI Compliant with PCI
Compliant with PCI Compliant with PCI
Bus specifications*1 Express® standard Express® standard Express® standard
standard Rev.2.2 standard Rev.2.2
Rev.1.1 Rev.1.1 Rev.2.0
Operating system (English Version)*2
Microsoft® Windows Server® 2008
●*3 ● −
Standard
Microsoft Windows Server 2008
●*3 ● −
Enterprise
Microsoft Windows Server 2008
●*3 ● −
Standard x64 Edition
Microsoft Windows Server 2008
●* 3
● −
Enterprise x64 Edition
Microsoft® Windows Server® 2008 R2
● ● −
Standard
Microsoft Windows Server 2008 R2
● ● −
Enterprise
Features
Microsoft Windows 7 Home
● ● −
Premium
Microsoft Windows 7 Professional ● ● ●
Microsoft® Windows® 7 Ultimate ● ● ●
Microsoft® Windows® 7 Enterprise ● ● ●
Microsoft® Windows Server® 2012
● ● −
Standard
Applications
Microsoft Windows Server 2012 R2
● ● −
Standard
Microsoft Windows 8
® ®
● ● −
Microsoft® Windows® 8 Pro ● ● −
Microsoft® Windows® 8 Enterprise ● ● −
Microsoft® Windows® 8.1 ● ● −
Microsoft® Windows® 8.1 Pro ● ● ●
Products
Microsoft® Windows® 8.1 Enterprise ● ● ●
Microsoft® Windows® 10 Home ● ● −
Microsoft® Windows® 10 Pro ● ● Coming soon!
For any other details on the operating environment, please refer to the relevant product manual.
36
CC-Link IE Control Network CC-Link IE Control Network
P r o d u c t s CC-Link IE Field Network
twisted-pair cable optical cable
37
Realize cyclic communication
with software implementation only
38
F e a t u r e s
Network
User applications
HTTP/ (Cyclic communication/transient communication/SLMP)
Application
FTP
software etc.
TCP/UDP
Protocol stack
IP
Communication driver Ethernet EIA-485
Standard managed
switch
Remote I/O Robot GOT (HMI) Inverter Servo amplifier Solenoid valve*2 Label Bar-code In-line industrial
printer reader weighing scale
39
Small-scale network system configuration
•• Reduce the space for module installation
•• Reduce hardware cost
Features
Simple setup and easy troubleshooting
Applications
•• Set up cyclic communication easily
•• Shorten the operating cycle when an error occurs
Products
Settings such as IP address can be easily done by automatically detecting slave devices using either the
GX Works3 or GX Works2 engineering tool. Maintenance is easier by being able to monitor the operating and
communication statuses of nodes connected on the network.
Options
Development tool
40
A p p l i c a t i o n s
Ethernet
Standard managed
Master station switch
Slave station
41
P r o d u c t s
MELSEC
iQ-R Series MELSEC
iQ-F Series
R□□CPU FX5U-□□□□/□□□
R□□ENCPU FX5UC-□□□□/□□□
•• 64 slave stations can be connected per network •• 6 slave stations can be connected per network
Features
R32CPU FX5U-32MR
Applications
MELSEC-Q
Series MELSEC-L
Series
Q□□UDVCPU L□□CPU(-P/-BT/-PBT)
•• 64 slave stations can be connected per network •• 16 slave stations can be connected per network
Products
Options
Q03UDVCPU L02CPU
Development tool
Product list
42
P r o d u c t s
MR-JE-□C
43
◾◾CC-Link IE Field Network Basic compatible GOT (HMI)
GOT2000 Series
HMI
GT27□□-□□□□ GT25□□□-□□□□ GT210□-□□BD
•• Cyclic communication is possible with CC-Link IE Field Network Basic
compatible devices via Ethernet interface of GOT (HMI)
•• TCP/IP communications are supported, enabling a highly-flexible system
Type*1 Screen size Panel color Power supply Multi-touch gesture functions
GT27
GT2715-XTBA 15”XGA Black 100…240 V AC ●
GT2715-XTBD 15”XGA Black 24 V DC ●
GT2712-ST□A 12.1”SVGA Black/white 100…240 V AC ●
GT2712-ST□D 12.1”SVGA Black/white 24 V DC ●
GT2710-STBA 10.4”SVGA Black 100…240 V AC ●
GT2710-STBD 10.4”SVGA Black 24 V DC ●
GT2710-VT□A 10.4”VGA Black/white 100…240 V AC ●
GT2710-VT□D 10.4”VGA Black/white 24 V DC ●
GT2708-STBA 8.4”SVGA Black 100…240 V AC ●
Features
GT2708-STBD 8.4”SVGA Black 24 V DC ●
GT2708-VTBA 8.4”VGA Black 100…240 V AC ●
GT2708-VTBD 8.4”VGA Black 24 V DC ●
GT2705-VTBD 5.7”VGA Black 24 V DC ●
GT25
GT2512-STBA 12.1”SVGA Black 100…240 V AC -
GT2512-STBD 12.1”SVGA Black 24 V DC -
GT2512F-STNA 12.1”SVGA - 100…240 V AC -
GT2512F-STND 12.1”SVGA - 24 V DC -
Applications
GT2510-VT□A 10.4”VGA Black/white 100…240 V AC -
GT2510-VT□D 10.4”VGA Black/white 24 V DC -
GT2510F-VTNA 10.4”VGA - 100…240 V AC -
GT2510F-VTND 10.4”VGA - 24 V DC -
GT2508-VT□A 8.4”VGA Black/white 100…240 V AC -
GT2508-VT□D 8.4”VGA Black/white 24 V DC -
GT2508F-VTNA 8.4”VGA - 100…240 V AC -
GT2508F-VTND 8.4”VGA - 24 V DC -
GT2510-WXT□D 10.1”WXGA Black/silver*2 24 V DC -
Products
GT2507-WT□D 7”WVGA Black/silver*2 24 V DC -
GT21
4.3”
GT2104-RTBD Black 24 V DC -
[480 x 272 dots]
4.5”
GT2104-PMBD Black 24 V DC -
[384 x 128 dots]
3.8”
GT2103-PMBD Black 24 V DC -
[320 x 128 dots]
Options
*1. “□” in the model name denotes panel color (B (black)/W (white)/S (silver)). For further details about model name, please refer to the “GOT 2000 Series consolidated catalogue (L(NA)08270ENG)”.
*2. The bottom part of the panel including the USB environmental protection cover is black.
Development tool
Product list
44
P r o d u c t s
MH11CTMF-N
45
◾◾CC-Link IE Field Network Basic Block type remote modules
•• CC-Link IE Field Network Basic slave station. These modules are useful when installation positions close to I/O
devices are required
•• Supports CC-Link IE Field Network Basic diagnostic function. Network error and I/O module fault can be
checked using the engineering software
•• Enables CC-Link parameters to be set with simple switch operations
Input modules
Screw terminal block
NZ2MFB1-32D NEW
NZ2MFB1-32D
Model Input type DC input Input points Rated input voltage/current Wiring type
NZ2MFB1-32D Positive common Negative common 32 points 24 V DC (6 mA) 1-wire
NZ2MFB2-16A
Features
NEW
Model Input type Input points Rated input voltage, frequency Rated input current Wiring type
8.2 mA (100 V AC, 60 Hz)
NZ2MFB2-16A AC input 16 points 100…120 V AC 2-wire
6.8 mA (100 V AC, 50 Hz)
Applications
Output modules
Screw terminal block
NZ2MFB1-32T NEW
NZ2MFB1-32TE1 NEW
Products
NZ2MFB1-32T
NZ2MFB2-16R NEW
NZ2MFB1-32DT NEW
NZ2MFB1-32DTE1 NEW NZ2MFB1-32DT
Product list
Input type Rated input voltage/ Output type Rated load voltage/
Model Input points Output points Wiring type
DC input current Transistor output Max. load current
NZ2MFB1-32DT Positive common 16 points 24 V DC (6 mA) Sink type 16 points 24 V DC (0.5 A) 1-wire
NZ2MFB1-32DTE1 Negative common 16 points 24 V DC (6 mA) Source type 16 points 24 V DC (0.1 A) 1-wire
46
CC-Link IE Control Network CC-Link IE Control Network
O p t i o n s CC-Link IE Field Network
twisted-pair cable optical cable
Options
◼◼Industrial switching hub
NZ2EHG-T8N
Powered by CONTEC
Using
along Ethernet network redundant topology
ERP
One managed CC-Link IE switch is connectable to Redundant network paths between switches enable a
CC‑Link IE and Ethernet networks simultaneously system to be continuously operated in case of failure
without requiring special network configuration
Ethernet
GOT (HMI) RFID reader
Remote I/O Master station
module
Intelligent device
NZ2MHG-T8F2 Error
station Vision sensor When an error occurs, communications are re-established
Local station Ethernet module
via an alternative network line (within 10 ms)
NZ2MHG-T8F2 NZ2MHG-T8F2
Multi-mode optical cable: up to 550 m NZ2MHG-T8F2
Single-mode optical cable: up to 5 km
*2. Either the optical port (OPT1/OPT2) or RJ45 port (P1/P2) can be used at a time.
Local station 1 Local station 2 Local station 3 Local station 4
47
Option
FA Partner Products
For details of Mitsubishi Electric System & Service Co., Ltd. products, please contact by sending an
Mitsubishi Electric System & Service e-mail to the following address.
<Sales office> FA PRODUCT DIVISION mail:[email protected]
Features
◼◼Ethernet cable
SC-E5EW Series
•• 1000BASE-T Standard compliant. This Ethernet cable with double shield has an
Applications
outstanding shield performance
•• Available in lengths from 1 m to 100 m (in 1 m increments), for using in indoor
movable area available lengths are from 1 m to 45 m
Item SC-E5EW-S□M*1 SC-E5EW-S□M-MV*2 SC-E5EW-S□M-L*1
Cable type Category 5e or higher, (Double shielded/STP) Straight cable
Number of core
8 wires (4 twisted pairs)
Products
wires
Double shield Aluminum/polyester tape, Tin-plated annealed copper wire braid
Installation
Indoor Indoor movable Indoor/Outdoor
environment
Finished outside *1. "□" in the model name denotes a cable
Flame retardant PVC, 6.8 mm Flame retardant PVC, 6.5 mm LAP sheath, 10 mm
diameter length (up to 100 m in 1 meter increments).
Connector RJ-45 connector with shield, straight connection *2. "□" in the model name denotes a cable
Conforming IEEE802.3 1000BASE-T length (up to 45 m in 1 meter increments).
standards ANSI/TIA/EIA-568-B (Category 5e) ISO/IEC 11801
Options
◼◼Inline coupler
SPAD-RJ45S-E5E
•• 8 conductor RJ-45 female to female, shielded, fits standard type Keystone Wall
Plate
Development tool
48
CC-Link IE Control Network CC-Link IE Control Network
O p t i o n s CC-Link IE Field Network
twisted-pair cable optical cable
◼◼Standard accessories: Protective holder*1 (One protective holder is enclosed per cable.)
Features
• Protects the cable connector base prevents breakage
• Maintains minimum bending radius
• Saves space in control panel (60 mm or less from the front of PLC to end of
protective holder)
*1. The protective holder is dedicated to the Mitsubishi Electric System Service Co., Ltd. LCF connector and is not available as a single unit. It
cannot be used with other LCF connector brands.
◼◼Splice adapter
SPAD-LCF-G50 SPAD-SCF-G50 SPAD-FC-G50
•• Extends optical cable (Splice connection)
•• Temporary connection for stations which may be extended later
Applicable
connector
Type Model Specifications
Splice adapter for LCF connector, multimode 2 cores
Splice adapter for LCF Connector SPAD-LCF-G50
Connection loss: 0.3 dB (with master fiber)
Splice adapter for SC connector, multimode 2 cores
Splice adapter for SC Connector SPAD-SCF-G50
Connection loss: 0.3 dB (with master fiber)
Splice adapter for FC connector, multimode 1 core SPAD-LCF-G50
Splice adapter for FC Connector SPAD-FC-G50
Connection loss: 0.3 dB (with master fiber)
Applicable
connector················································ LCF/LC/SC/MU connector
49
Mitsubishi Electric System & Service
DMC-1000SL-DC
Application
example Specifications
DMC-1000SL-DC
Item
OPT1 port OPT2 port
IEEE802.3z Gigabit Ethernet IEEE802.3z Gigabit Ethernet
Conforming standard
(1000BASE-LX) (1000BASE-SX)
Transmission format Full duplex system
DMC-1000SL-DC DMC-1000SL-DC 1000BASE-SX compatible
Features
Optical 1000BASE-LX compatible multi-mode optical fiber cable*1
fiber single-mode optical fiber cable / (Band: 500 MHz · km or higher,
Multi-mode λ=850 nm)
Factory A optical fiber cable Factory B Duplex LC connector Duplex LC connector
(up to 550 m) Compatible Connector
cable (IEC 61754-20) (IEC 61754-20)
DMC-1000SL-DC DMC-1000SL-DC Polishing
method of PC, SPC, AdPC, UPC polish PC, SPC polish
connector
Method for
Crossing (A to B , B to A)
connection
Single-mode Single-mode Power supply
Applications
optical fiber cable optical fiber cable 20.4 V…26.4 V DC (Power supply terminal block)
specification
(up to 15 km) (up to 15 km) Standards UL, CE, FCC Part15 Class B, VCCI Class B
Series connection 4 (max.)
*1. For DMC-1000SL-DC: Optical fiber cable with a LC duplex connectors on both side
Factory C
◼◼Connection terminal
Products
SC-ECT-P3
•• Enables up to 3 stations to be added between existing stations
•• With stations that can easily be added or removed, the maintainability is
improved
•• Allows for expansion of the network without having to change the existing
cabling Options
•• Installable on the DIN rail or with screw brackets
Communication
configuration example Specifications
Item Specifications
1000 BASE-SX (MMF)-compatible optical fiber cable
Standard IEC60793-2-10 Types A1a.1 (50/125 μm multimode)
Applicable Transmission loss
Development tool
Number of possible
Max. 3 units
connections
Connection distance Max. 150 m*5
*4. Parts provided by Mitsubishi Electric System & Service.
Additional stations *5. Cable length from SC-ECT-P3 to any other connection point.
The products listed here are manufactured by Mitsubishi Electric System & Service Co., Ltd. Please note that the specifications and guarantee conditions of the
products are different from the MELSEC Series products.
50
D e v e l o p m e n t t o o l
Reference manual
OS (non-Windows®)
Application Driver*1
source codes and circuit examples (PDF), aiming to Source code Reference manual
save the developer's programming time and cost
*2. Does not support local station development.
Type Model
Source code development CD-ROM SW1DNC-EFI210SRC
Type Model Packaging unit
Dedicated NZ2GACP210-60 60 pieces
communication LSI CP210 NZ2GACP210-300 300 pieces
51
◾◾Communication LSI embedded with GbE-PHY CP520
•• The items shown on the right support development
of CC-Link IE Field Network slave stations, without
requiring in-depth knowledge of the protocol
•• CP520 supports development of CC-Link IE Field
Network intelligent device station and remote device
Communication LSI embedded with GbE-PHY
station
•• CP 520 is integrated communication LSI embedded
with CC-Link IE Field Network communication ASIC,
MPU, and GbE-PHY
•• The integrated communication LSI saves the CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code
MADE IN JAPAN
developer's programming time and cost related to C 2014 MITSUBISHI ELECTRIC CORPORATION
ALL RIGHTS RESERVED
Features
Reference manual SH(NA)-081570ENG Intelligent Device Station Communication LSI
Embedded with GbE-PHY CP520 Reference Manual
Applications
of CC-Link IE Field Network slave stations, without
requiring in-depth knowledge of the protocol
•• CP220 is a dedicated communication LSI for
intelligent device stations of CC-Link IE Field
Dedicated communication LSI
Network
•• The reference manual CD-ROM contains C program
Products
sample codes and circuit examples (PDF), aiming to
save the developer's programming time and cost
CC-Link IE Field Network
Q80BD-J71GF11-T2/Q81BD-J71GF11-T2
Driver Development
Sample Code
MADE IN JAPAN
For price and other details, please contact your local Mitsubishi Electric office or sales representative.
Membership (regular, executive, or board membership) to CC-Link Partner Association (CLPA) is required for purchasing the development tools for CC-Link IE Field
Network source code development and for the development incorporating the communication LSI embedded with GbE-PHY, CP520 and dedicated communication
LSI, CP220.
CC-Link Partner Association URL: http://www.cc-link.org
Product list
The license agreement must be signed prior to using the development tools for CC-Link IE Field Network source code development.
For hardware/software development, a referral to a partner is available on request.
Mitsubishi Electric Corporation Open System Center supports development using the development tools described in this section.
52
D e v e l o p m e n t t o o l
Specifications
Item
Safety remote I/O module
Operating ambient
0…55°C
temperature
Storage ambient
-40…75°C
temperature
Operating ambient
humidity 5…95%RH, non-condensing
Storage ambient humidity
Compliant with JIS B 3502, IEC 61131-2
Frequency Acceleration Half amplitude Sweep count
5…8.4 Hz - 3.5 mm 10 times each in
Vibration resistance Under intermittent vibration
8.4…150 Hz 9.8 m/s2 - X, Y, Z directions
5…8.4 Hz - 1.75 mm
Under continuous vibration -
8.4…150 Hz 4.9 m/s 2
-
Shock resistance Compliant with JIS B 3502, IEC 61131-2 (147 m/s2, 3 times in each of 3 directions X, Y, Z)
Operating ambient
No corrosive gases*6, flammable gases, less conductive dust
(humidity/temperature)
Operating altitude*2 0…2000 m*3
Installation location Inside a control panel
Overvoltage category*4 ≤2
Pollution level*5 ≤2
Equipment class Class 3
*1. The module satisfies IP67 rating only when all waterproof plugs and caps are fitted and screws for a station setting switch cover are properly tightened.
*2. Do not use or store the programmable controller under pressure higher than the atmospheric pressure of altitude 0 m. Doing so may cause malfunction.
When using the programmable controller under pressure, please consult your local Mitsubishi Electric representative.
*3. When the programmable controller is used at altitude above 2000 m, the withstand voltage performance and the upper limit of the operating ambient temperature decrease. When using the
programmable controller under pressure, please contact your sales representative.
*4. This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within premises. Category
II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*5. This index indicates the degree to which conductive material is generated in terms of the environment in which the equipment is used.
Pollution level 2 is when only non-conductive pollution occurs. A temporary conductivity caused by condensing must be expected occasionally.
*6. Use the special coated products which comply with the IEC 60721-3-3 3C2 in the environment with the corrosive gases.
For details on the special coated products, please contact your sales representative.
53
CC-Link IE Field Network performance specifications
MELSEC iQ-R MELSEC iQ-R MELSEC-Q
Series Network interface Series
MELSEC iQ-R MELSEC-Q MELSEC-L Series
R04ENCPU board simple motion
Series Series Series simple motion
R08ENCPU Q80BD- module
Item master/local master/local master/local module
R16ENCPU J71GF11-T2, RD77GF4
module module module QD77GF4
R32ENCPU Q81BD- RD77GF8
RJ71GF11-T2 QJ71GF11-T2 LJ71GF11-T2 RD77GF16 QD77GF8
R120ENCPU J71GF11-T2
RD77GF32 QD77GF16
RJ71EN71
Communication speed 1 Gbps
Maximum stations per network 121 stations (1 master station. 120 slave stations)
Connection cable Ethernet cable (Category 5e or higher, double shielded/STP), straight cable
Line type: 12,000 m (When 1
Line type: 12,000 m (When 1 master station and 120 slave stations are connected) master station and 120 slave
Overall cable distance Star type: Depends on system configuration*1 stations are connected)
Ring type: 12,100 m (When 1 master station and 120 slave stations are connected) Star type: Depends on system
configuration*1
Maximum station-to-station distance 100 m
Maximum number of networks 239
Network topology Line type, star type*2, ring type Line type, star type*2
Communication method Token-pass
Maximum link points per network*3
8192 points,
RX 16384 points, 2K bytes
1K bytes
8192 points,
RY 16384 points, 2K bytes
1K bytes
1024 points,
RWr 8192 points, 16K bytes
2K bytes
1024 points,
RWw 8192 points, 16K bytes
2K bytes
Maximum link points per station*3
8192 points,
RX 16384 points, 2K bytes
1K bytes
8192 points,
RY 16384 points, 2K bytes
1K bytes
Master station
1024 points,
RWr 8192 points, 16K bytes
2K bytes
1024 points,
RWw 8192 points, 16K bytes
2K bytes
RX 2048 points, 256 bytes -
RY 2048 points, 256 bytes -
Local station* 4
RWr 1024 points, 2048 bytes 256 points, 512 bytes -
RWw 1024 points, 2048 bytes 256 points, 512 bytes -
RX 2048 points, 256 bytes
RY 2048 points, 256 bytes
Intelligent device 1024 points,
RWr 1024 points, 2048 bytes 256 points, 512 bytes
station 2048 bytes
1024 points,
RWw 1024 points, 2048 bytes 256 points, 512 bytes
2048 bytes
RX 128 points, 16 bytes
Remote device RY 128 points, 16 bytes
station RWr 64 points, 128 bytes
RWw 64 points, 128 bytes
Safety communications
Maximum number of safety 1814
- -
connections per network connections
Maximum number of safety 120
- -
connections per station connections
8 words
Maximum number of link points
- (input: 8 words, -
per safety connection
output: 8 words)
Transient transmission capacity
Transient transmission capacity 1920 bytes maximum
*1. A hub is required to use the star type wiring. Up to 20 hubs can be connected.
*2. Line and star types can also be mixed.
*3. Remote input RX: Bit data input from a slave station to the master station
Remote output RY: Bit data output from the master station to a slave station
Remote register RWr: 16-bit (word) unit data output from the master station to a slave station
Remote register RWw: 16-bit (word) unit data output from the master station to a slave station
* May partially differ for local stations
*4. Number of link points allocated by the master station. A local station can also use other link points to receive data from other stations.
54
CC-Link IE Control Network performance specifications
MELSEC iQ-R Series
R04ENCPU Network interface board
R08ENCPU MELSEC-Q Series Q80BD-J71GP21-SX
MELSEC iQ-R Series
Item R16ENCPU QJ71GP21-SX Q80BD-J71GP21S-SX
RJ71GP21-SX
R32ENCPU QJ71GP21S-SX Q81BD-J71GP21-SX
R120ENCPU Q81BD-J71GP21S-SX
RJ71EN71
Communication speed 1 Gbps
Maximum stations per
120 (1 control station, 119 normal stations)*1
network
Ethernet cable
(Category 5e or higher,
Connection cable Multi-mode optical cable
double shielded/STP),
straight cable
Laser class (JIS C 6802,
- Class 1 laser product
IEC 60825-1)
Line type: 11,900 m*2
Star type: Depends on system
Overall cable distance 66,000 m*2
configuration
Ring type: 12,000 m*2
Maximum station-to-
100 m 550 m
station distance
Maximum number of
239
networks
Maximum number of
32
groups
Network topology Line type, star type*3, ring type Duplex loop ring
Communication method Token-pass Token-ring
Maximum link points per network*4
LB 32768 points, 4K bytes 32768 points, 4K bytes*5 32768 points, 4K bytes
LW 131072 points, 256K bytes 131072 points, 256K bytes*6 131072 points, 256K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Communication speed*4 (Regular mode)
LB 16384 points, 2K bytes
LW 16384 points, 32K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Communication speed*4 (Extended mode*7)
LB 32768 points, 4K bytes
LW 131072 points, 256K bytes
LX 8192 points, 1K bytes
LY 8192 points, 1K bytes
Transient transmission capacity
Transient transmission
1920 bytes maximum
capacity
*1. Under CC-Link IE Control Network, the number of connectable normal stations per network differs by the CPU module used in the control station.
For the details, please refer to the manual of the module used in the control station.
*2. When 120 stations are connected.
*3. Line and star types can also be mixed.
*4. Link relay LB: Bit data transmitted from stations in the network.
Link register LW: 16-bit (word) unit data transmitted from stations in the network.
Link input LX: Data input from a station to the I/O master in the same block.
Link output LY: Data output from the I/O master station to another station in the same block.
*5. 16384 points and 2K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU.
*6. 16384 points and 32K bytes for the basic model QCPU and the MELSEC-QS Series Safety CPU.
*7. To use the extended mode, all the stations must be compatible with the extended mode.
55
CC-Link IE Field Network Basic performance specifications
MELSEC iQ-R Series MELSEC-Q Series MELSEC-L Series MELSEC iQ-F Series
Item R◻CPU FX5U
Q◻UDVCPU L◻CPU
R◻ENCPU FX5UC
Communication speed 100 Mbps
Maximum stations per network*1 64 stations (16 stations × 4 groups) 16 stations 6 stations
Connection cable Ethernet standard compatible cable, Category 5e or higher (STP cable)
Maximum station-to-station
100 m (between a hub and node)*2
distance
Network topology Star type
Communication method UDP
Maximum link points per network*3
RX 4096 points 1024 points 384 points
RY 4096 points 1024 points 384 points
RWr 2048 points 512 points 192 points
RWw 2048 points 512 points 192 points
Maximum link points per station*3
RX 4096 points 1024 points 384 points
RY 4096 points 1024 points 384 points
Master station
RWr 2048 points 512 points 192 points
RWw 2048 points 512 points 192 points
RX 64 points; up to 256 points can be allocated according to the number of stations
RY 64 points; up to 256 points can be allocated according to the number of stations
Slave station*4
RWr 32 points; up to 128 points can be allocated according to the number of stations
RWw 32 points; up to 128 points can be allocated according to the number of stations
*1. Maximum number of slave stations controlled by the master station, depending on the number of allocated slave stations. The total number of allocated stations should not exceed the maximum number
of slave stations.
*2. The maximum distance between stations depends on the actual hub used. Please refer to the hub manufacturer’s specifications.
*3. Remote input RX: Bit data input from a slave station to the master station
Remote output RY: Bit data output from the master station to a slave station
Remote register RWr: 16-bit (word) unit data output from the master station to a slave station
Remote register RWw: 16-bit (word) unit data output from the master station to a slave station
*4. Number of link points allocated by the master station.
56
Cable specifications
CC-Link IE compatible twisted-pair cable*1
Item Specifications
Category 5e or higher, (double shielded/STP) straight cable
Twisted-pair cable Cables that conform to the following standards.
specifications Standard • IEEE802.3 (10000BASE-T)
• ANSI/TIA/EIA-568-B (Category 5e)
Connector
Standard RJ-45 connector with shield
specifications
Network topologies*2
*2. CC-Link IE Field Network Basic supports star topology only.
Station-to-station
Station-to-station distance: distance: max.
max. 100 m 100 m
Master/Control station
Local/Normal station
57
Cyclic transmission
In cyclic transmission, data is transmitted periodically using link devices. Under CC-Link IE Field and Control
networks, some differences exist as described in this section.
Station No. 0 Station No. 1 Station No. 2 Station No. 3 Station No. 4
CPU module Master station Slave station Slave station Local station Local station CPU module
Device RX, RWr RX, RWr RX, RWr RX, RWr Device
Station No. 1
Station No. 1 ❼ transmission Station No. 1 Station No. 1
area RX, RWr
Station No. 2
❽ Station No. 2 ❼ transmission Station No. 2 Station No. 2 ❹
Program area Program
scan scan
Link Station No. 3 ❼ Station No. 3 Station No. 3 Link
N
D
E
EN refresh refresh D
Station No. 4 ❼ Station No. 4 Station No. 4
Link
scan
Device RY, RWw RY, RWw RY, RWw RY, RWw Device
M0 M0
Y ❶ : Area used to transmit data to other stations ❺ Y
58
◾◾CC-Link IE Control Network
Communications using link relays (LB) and link registers (LW)
This function allows each station to write data to its own send range of a link device (LB, LW) to send them to all
other stations on the network. The status data of the control station link devices (LB, LW) are stored in the link
devices (LB, LW) of each normal station. Likewise, the status of the normal station link devices (LB, LW) is stored
in link devices (LB, LW) of the control and other normal stations.
E
EN area D
Station No. 4
Station No. 4 Station No. 4 Station No. 4 transmission
area
Transmission request B
B ➊
: Area used to transmit data to other stations
Transmissions using link inputs (LX) and link outputs (LY)
An I/O master station, which controls link inputs (LX) and link outputs (LY), and another station make one to one
communication. LX is the input data transmitted between stations in a block, and LY is the output data transmitted
from the I/O master station in a block. The control or normal station can be an I/O master station, and up to two I/O
master stations (block 1 and block 2) can be used per network.
Control station Normal station Normal station Normal station
(Station No. 1) (Station No. 2) (Station No. 3) (Station No. 4)
Block 1
LX
I/O master
station
LY
LX
LY LX LY LY LX
Block 2
LX
I/O master
LY station
Normal station Normal station Normal station Normal station
(Station No. 5) (Station No. 6) (Station No. 7) (Station No. 8)
Transient transmission
This function allows communications with other stations when a request is made by a method such as a dedicated
instruction and engineering tool. Communications with different networks is also possible.
59
Extensive global support coverage
providing expert help whenever needed
■ Global FA centers
@5
@2 @1
@3@0
MITSUBISHI ELECTRIC
@4 @6 w CORPORATION !7
e y Nagoya Works
q
!6 !3 r
!0 t !8
!2
!4!5 u
!1
i
o
!9
60
CC-Link Partner Association (CLPA) - Actively
promoting worldwide adoption of CC-Link networks
Proactively supporting CC-Link, from promotion to specification development
The CC-Link Partner Association (CLPA) was established to promote the worldwide adoption of the CC-Link open-field network. By
conducting promotional activities such as organizing trade shows and seminars, conducting conformance tests, and providing catalogs,
brochures and website information, CLPA activities are successfully increasing the number of CC-Link partner manufacturers and
CC-Link-compatible products. As such, CLPA is playing a major role in the globalization of CC-Link.
CC-Link-Europe CT
(Germany)
CLPA-Korea CT
(Seoul)
CLPA-North America CT
(Vernon Hills, Illinois, USA)
CLPA-China CT CLPA Headquarters
(Shanghai) (Nagoya, Japan)
CT
CLPA-Americas NEW
(Mexico office)
CLPA-Taiwan (Tlalnepantla)
CLPA-Turkey (Taipei)
(Istanbul)
CC-Link
CLPA-India Promotion Center Thailand NEW
(Gurgaon) (Bangkok)
61
Factory Automation Global website
Mitsubishi Electric Factory Automation provides a mix of services to support its customers worldwide. A
consolidated global website is the main portal, offering a selection of support tools and a window to its local
Mitsubishi Electric sales and support network.
Online e-learning
An extensive library of e-learning courses covering the factory automation product range has been prepared.
Courses from beginner to advanced levels of difficulty are available in various languages.
■ Beginner level
Designed for newcomers to Mitsubishi Electric
Factory Automation products gaining a background
of the fundamentals and an overview of various
products related to the course.
62
Innovative next-generation, e-Manual
The e-Manual viewer is a next-generation digital manual offered by Mitsubishi Electric that consolidates all
manuals into an easy-to-use package with various useful features integrated into the viewer. The e-Manual is
modeled around a centralized database allowing multiple manuals to be cross-searched at once, further reducing
the time for reading individual product manuals when setting up a control system.
iOS Android™
Version 8.1 or later Version 4.3/4.4/5.0
Supported versions
OS OS version Model
Apple iPad 2, iPad (3rd generation), iPad (4th generation), iPad Air, iPad Air 2,
iOS iOS 8.1 or later
iPad mini, iPad mini 2, iPad mini 3
Android™ Android™ 4.3/4.4/5.0 ASUS Nexus7™ (2013)*1
*1: When using a tablet not listed above, 7-inch (resolution of 1920×1200 dots (WUXGA)) or better is recommended.
63
P r o d u c t l i s t
Product list
Mitsubishi Electric Corporation …CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
Features
CC-Link IE Control Network control/normal station (with the External power supply function)
QJ71GP21S-SX - - ●
for MELSEC-Q Series
Simple motion module
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF4 Up to 4-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF8 Up to 8-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
Applications
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF16 Up to 16-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC iQ-R Series
RD77GF32 NEW Up to 32-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF4 Up to 4-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
Products
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF8 Up to 8-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
CC-Link IE Field Network master station for MELSEC-Q Series
QD77GF16 Up to 16-axis control, linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
Head module
Options
RJ72GF15-T2 MELSEC iQ-R Series CC-Link IE Field Network compatible remote head module ● - -
LJ72GF15-T2 MELSEC-L Series CC-Link IE Field Network compatible head module (END cover enclosed) ● - -
Intelligent device station module
FX5-CCLIEF MELSEC iQ-F Series CC-Link IE Field Network intelligent device station module ● - -
AC Servo MELSERVO-J4 Series
MR-J4-GF(-RJ) CC-Link IE Field Network compatible servo amplifier ● - -
Inverter FREQROL-A800 Series
FR-A800-GF CC-Link IE Field Network compatible inverter ● - -
HMI GOT2000 Series
Development tool
64
P r o d u c t l i s t
Mitsubishi Electric Corporation …CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
65
Product list
…CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
Mitsubishi Electric Corporation [ Legend ] DB : Double brand product*
Features
Analog output NZ2EX2B-60DA4 ● - -
screw terminal block
Waterproof/dustproof type (IP67) remote module
NZ2GF12A4-16D 16 points, 24 V DC, response time 0…70 ms, positive common, waterproof connector,
● - -
DB NEW 2…4-wire
DC input
NZ2GF12A4-16DE 16 points, 24 V DC, response time 0…70 ms, negative common, waterproof connector,
● - -
DB NEW 2…4-wire
NZ2GF12A2-16T
16 points, 12/24 V DC (2 A), sink type, waterproof connector, 2-wire ● - -
Transistor DB NEW
Applications
output NZ2GF12A2-16TE
16 points, 12/24 V DC (2 A), source type, waterproof connector, 2-wire ● - -
DB NEW
Input 8 points, 24 V DC, response time 0…70 ms, positive common, 2…4-wire
NZ2GF12A42-16DT
Output 8 points, 12/24V DC (2 A), sink type, 2-wire ● - -
DB NEW
waterproof connector
I/O combined
Input 8 points, 24 V DC, response time 0…70 ms, negative common, 2…4-wire
NZ2GF12A42-16DTE
Output 8 points, 12/24 V DC (2 A), source type, 2-wire ● - -
DB NEW
waterproof connector
Safety remote I/O module
Products
Main safety 32 points with single wiring/16 points with double wiring, 24 V DC, response time 0.4 ms,
NZ2GFSS2-32D ● - -
input negative common, spring clamp terminal block, 2-wire
Extension 8 points with single wiring/4 points with double wiring, 24 V DC (0.5 A),
NZ2EXSS2-8TE ● - -
safety output source + source type, spring clamp terminal block, 2-wire
Network interface board
Q81BD-J71GF11-T2 CC-Link IE Field Network master/local station, compatible with PCI Express® bus ● - -
Q80BD-J71GF11-T2 CC-Link IE Field Network master/local station, compatible with PCI/PCI X bus ● - -
Q81BD-J71GP21-SX CC-Link IE Control Network control/normal station, compatible with PCI Express® bus - - ●
CC-Link IE Control Network control/normal station (with the External power supply function),
Q81BD-J71GP21S-SX - -
Options
●
compatible with PCI Express® bus
Q80BD-J71GP21-SX CC-Link IE Control Network control/normal station, compatible with PCI/PCI X bus - - ●
CC-Link IE Control Network control/normal station (with the External power supply function),
Q80BD-J71GP21S-SX - - ●
compatible with PCI/PCI X bus
PCI Express® bus type CC-Link IE Field Network simple motion board
MR-EM340GF max. control axis:16 linear interpolation, 2-axis circular interpolation, synchronous control, ● - -
speed-torque control
*1. A connector for the power supply and FG is required with e-CON and MIL connector type remote I/O module. Please refer to the option list on P.47 to check the type and model name.
Development tool
*2. A sensor connector is required with e-CON connector type remote I/O module. Please refer to the option list of Mitsubishi Electric System & Service Co., Ltd. products on P.48 to check the type and
model name.
66
P r o d u c t l i s t
67
Option list
…CC-Link IE Field Network …CC-Link IE Control Network twisted-pair cable …CC-Link IE Control Network optical cable
Mitsubishi Electric Corporation [ Legend ] DB : Double brand product*
Features
*1. Model name by the plug manufacturer 3M.
*2. The allowable current value of the cable connected must be observed.
Mitsubishi Electric System & Service Co., Ltd. …CC-Link IE Field Network …CC-Link IE Control Network twisted pair cable …CC-Link IE Control Network optical cable
Applications
Cable/accessory
SC-E5EW-S□M (Double shielded/STP) straight cable, Category 5e, for indoor use ● ● -
SC-E5EW-S□M-MV (Double shielded/STP) straight cable, Category 5e, for indoor movable part ● ● -
SC-E5EW-S□M-L (Double shielded/STP) straight cable, Category 5e, for indoor/outdoor use ● ● -
SPAD-RJ45S-E5E RJ-45 connector with shield ● ● -
QG-AW Optical fiber cable compatible with CC-Link IE Control Network (in the control panel) - - ●
QG-B Optical fiber cable compatible with CC-Link IE Control Network (indoor) - - ●
QG-BU UL optical fiber cable compatible with CC-Link IE Control Network (indoor) - - ●
QG-C Optical fiber cable compatible with CC-Link IE Control Network (outdoor) - - ●
Products
QG-DL Optical fiber cable compatible with CC-Link IE Control Network (outdoor, reinforced) - - ●
QG-VCT Optical fiber cable compatible with CC-Link IE Control Network (indoor, movable use) - - ●
SPAD-LCF-G50 Splice adapter for LCF connector, multimode 2 cores, connection loss 0.3 dB (with master fiber) - - ●
SPAD-SCF-G50 Splice adapter for SC connector, multimode 2 cores, connection loss 0.3 dB (with master fiber) - - ●
SPAD-FC-G50 Splice adapter for FC connector, multimode 1 core, connection loss 0.3 dB (with master fiber) - - ●
Connector insertion tool (applicable connector: LCF connector, LC connector, SC connector,
SCT-SLM - - ●
MU connector)
Optical media converter
Options
DMC-1000SL-DC Optical media converter compatible with CC-Link IE Control Network (24 V DC) - - ●
Connection terminal
SC-ECT-P3 Cable bundling device compatible with CC-Link IE Control Network - - ●
Sensor connector (e-CON) for Block type remote module
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
ECN-M014R ● - -
Outer diameter of applicable cable: ø0.8…1.0 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
ECN-M024Y ● - -
Outer diameter of applicable cable: ø1.0…1.2 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.14…0.30 mm2 (26…24 AWG)
Development tool
ECN-M034OR ● - -
Outer diameter of applicable cable: ø1.2…1.6 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M044GN ● - -
Outer diameter of applicable cable: ø1.0…1.2 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M054BL ● - -
Outer diameter of applicable cable: ø1.2…1.6 mm, Maximum rated current: 2.0 A, 20 pieces
Core wire size of applicable cable: 0.30…0.50 mm2 (22…20 AWG)
ECN-M064GY ● - -
Outer diameter of applicable cable: ø1.6…2.0 mm, Maximum rated current: 2.0 A, 20 pieces
Product list
For details of Mitsubishi Electric System & Service Co., Ltd. products, please contact by sending an e-mail to the following address.
<Sales office> FA PRODUCT DIVISION mail:[email protected]
* General specifications and product guarantee conditions of jointly developed products are different from those of MELSEC products.
For further details, please refer to the product manuals, or contact your local Mitsubishi Electric sales representative.
68
Microsoft, Windows, Windows Vista, Windows Server, Visual Basic, Visual C++, and Visual Studio are registered trademarks of Microsoft Corporation in the United States and
other countries.
Ethernet is a trademark of Xerox Corporation.
MODBUS is a registered trademark of Schneider Electric USA, Inc.
All other company names and product names used in this document are trademarks or registered trademarks of their respective companies.
This publication explains the typical features and functions of the products herein •• To use the products given in this publication properly, always read the relevant
manuals before beginning operation.
and does not provide restrictions or other information related to usage and module •• The products have been manufactured as general-purpose parts for general
combinations. Before using the products, always read the product user manuals. industries, and are not designed or manufactured to be incorporated in a device or
system used in purposes related to human life.
Mitsubishi Electric will not be held liable for damage caused by factors found not to
•• Before using the products for special purposes such as nuclear power, electric
be the cause of Mitsubishi Electric; opportunity loss or lost profits caused by faults in power, aerospace, medicine or passenger-carrying vehicles, consult with Mitsubishi
Mitsubishi Electric products; damage, secondary damage, or accident compensation, Electric.
whether foreseeable or not, caused by special factors; damage to products other than •• The products have been manufactured under strict quality control. However, when
installing the products where major accidents or losses could occur if the products
Mitsubishi Electric products; or any other duties. fail, install appropriate backup or fail-safe functions in the system.
69
Automation solutions
Mitsubishi Electric offers a wide range of automation equipment from PLCs and HMIs to
CNC and EDM machines.
70
Country/Region Sales office Tel/Fax
USA MITSUBISHI ELECTRIC AUTOMATION, INC. Tel : +1-847-478-2100
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A. Fax : +1-847-478-2253
Mexico MITSUBISHI ELECTRIC AUTOMATION, INC. Mexico Branch Tel : +52-55-3067-7500
Mariano Escobedo #69, Col. Zona Industrial, Tlalnepantla Edo. Mexico, C.P.54030
Brazil MITSUBISHI ELECTRIC DO BRASIL COMÉRCIO E SERVIÇOS LTDA. Tel : +55-11-4689-3000
Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil Fax : +55-11-4689-3016
Germany MITSUBISHI ELECTRIC EUROPE B.V. German Branch Tel : +49-2102-486-0
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany Fax : +49-2102-486-1120
UK MITSUBISHI ELECTRIC EUROPE B.V. UK Branch Tel : +44-1707-28-8780
Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, U.K. Fax : +44-1707-27-8695
Ireland MITSUBISHI ELECTRIC EUROPE B.V. Irish Branch Tel : +353-1-4198800
Westgate Business Park, Ballymount, Dublin 24, Ireland Fax : +353-1-4198890
Italy MITSUBISHI ELECTRIC EUROPE B.V. Italian Branch Tel : +39-039-60531
Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7, 20864 Agrate Brianza (MB), Italy Fax : +39-039-6053-312
Spain MITSUBISHI ELECTRIC EUROPE, B.V. Spanish Branch Tel : +34-935-65-3131
Carretera de Rubí, 76-80-Apdo. 420, 08190 Sant Cugat del Vallés (Barcelona), Spain Fax : +34-935-89-1579
France MITSUBISHI ELECTRIC EUROPE B.V. French Branch Tel : +33-1-55-68-55-68
25, Boulevard des Bouvets, 92741 Nanterre Cedex, France Fax : +33-1-55-68-57-57
Czech Republic MITSUBISHI ELECTRIC EUROPE B.V. Czech Branch Tel : +420-251-551-470
Avenir Business Park, Radlicka 751/113e, 158 00 Praha 5, Czech Republic Fax : +420-251-551-471
Poland MITSUBISHI ELECTRIC EUROPE B.V. Polish Branch Tel : +48-12-347-65-00
ul. Krakowska 50, 32-083 Balice, Poland Fax : +48-12-630-47-01
Sweden MITSUBISHI ELECTRIC EUROPE B.V. (Scandinavia) Tel : +46-8-625-10-00
Fjelievägen 8, SE-22736 Lund, Sweden Fax : +46-46-39-70-18
Russia MITSUBISHI ELECTRIC (RUSSIA) LLC St. Petersburg Branch Tel : +7-812-633-3497
Piskarevsky pr. 2, bld 2, lit “Sch”, BC “Benua”, office 720; 195027 St. Petersburg, Russia Fax : +7-812-633-3499
Turkey MITSUBISHI ELECTRIC TURKEY A.Ş Ümraniye Branch Tel : +90-216-526-3990
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye/Istanbul, Turkey Fax : +90-216-526-3995
UAE MITSUBISHI ELECTRIC EUROPE B.V. Dubai Branch Tel : +971-4-3724716
Dubai Silicon Oasis, P.O.BOX 341241, Dubai, U.A.E. Fax : +971-4-3724721
South Africa ADROIT TECHNOLOGIES Tel : +27-11-658-8100
20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa Fax : +27-11-658-8101
China MITSUBISHI ELECTRIC AUTOMATION (CHINA) LTD. Tel : +86-21-2322-3030
Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China Fax : +86-21-2322-3000
Taiwan SETSUYO ENTERPRISE CO., LTD. Tel : +886-2-2299-2499
6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan Fax : +886-2-2299-2509
Korea MITSUBISHI ELECTRIC AUTOMATION KOREA CO., LTD. Tel : +82-2-3660-9530
7F-9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu, Seoul 07528, Korea Fax : +82-2-3664-8372
Singapore MITSUBISHI ELECTRIC ASIA PTE. LTD. Tel : +65-6473-2308
307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943 Fax : +65-6476-7439
Thailand MITSUBISHI ELECTRIC FACTORY AUTOMATION (THAILAND) CO., LTD. Tel : +66-2682-6522
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road, Fax : +66-2682-6020
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Vietnam MITSUBISHI ELECTRIC VIETNAM COMPANY LIMITED Hanoi Branch Tel : +84-4-3937-8075
6th Floor, Detech Tower, 8 Ton That Thuyet Street, My Dinh 2 Ward, Nam Tu Liem District, Hanoi, Vietnam Fax : +84-4-3937-8076
Indonesia PT. MITSUBISHI ELECTRIC INDONESIA Tel : +62-21-3192-6461
Gedung Jaya 11th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia Fax : +62-21-3192-3942
India MITSUBISHI ELECTRIC INDIA PVT. LTD. Pune Branch Tel : +91-20-2710-2000
Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune-411026, Maharashtra, India Fax : +91-20-2710-2100
Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD. Tel : +61-2-9684-7777
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245
Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO 14001 (standards for environmental
management systems) and ISO 9001 (standards for quality assurance management systems).
HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
www.MitsubishiElectric.com