Installman KM 1.2.2 en
Installman KM 1.2.2 en
Minolta V1.2.2
Installation Manual - North America only
Versioning
Document Version Date Author(s) Reviewer(s)
Versioning
Business I.T.
2.0 01-Aug-2014 Sebastian Husnik, Thomas Lemmer
Systems Ltd
2.1 20-Nov-2014 Felix Schlick Thomas Lemmer
Claudia
2.2 17-Apr-2015 Paul Sluzek, Thomas Lemmer
Kleinekemper
Sebastian
2.3 25-Aug-2015 Thomas Lemmer
Husnik
Claudia
2.4 13-Nov-2015 Paul Sluzek, Thomas Lemmer
Kleinekemper
Sebastian
2.5 01-Jun-2016 Jan Droste
Husnik
Sebastian
2.6 03-Aug-2016 Thomas Lemmer
Husnik
Thomas
2.7 03-Aug-2016 Thomas Lemmer
Lemmer
Document Name uniFLOW Embedded Applet for Konica Minolta V1.2.2 - Installation Manual - V3.5
File Name uniFLOW Embedded Applet for Konica Minolta V1.2.2 - Installation Manual - V3.5.pdf
Technologies
uniFLOW, Konica Minolta, Embedded Applet Interface
Concerned
Short Summary Describes the installation of the uniFLOW Embedded Applet for Konica Minolta.
The embedded applet and the software documentation have been created by Business I.T. Systems
Ltd.
Pictograms
Important Note:
Information that is crucial for the correct functioning of the uniFLOW software.
Further Information:
Pointer to additional manuals, installation manuals, white papers or the NT-ware
Knowledgebase.
External Link:
Link to an external web page.
Settings:
Detailed explanation of configuration settings or operational procedures.
Compass:
Path to the menu or configuration page in the software.
Contents
1 Introduction ............................................................................................... 1
2 Feature List................................................................................................. 1
4 Requirements ............................................................................................. 4
4.1 Konica Minolta Client .................................................................................................... 4
4.2 uniFLOW ....................................................................................................................... 4
4.3 Compatibility / Device Requirements ............................................................................ 5
4.3.1 Checking Firmware Versions .......................................................................................................... 6
4.4 Device Settings ............................................................................................................. 6
10 Configuration in uniFLOW......................................................................... 23
13 Troubleshooting ....................................................................................... 30
13.1 Log File ....................................................................................................................... 32
13.2 Login Delay with Session Based Accounting ................................................................. 32
13.3 Network Communication Ports ................................................................................... 32
14 Index ........................................................................................................ 33
I
uniFLOW Embedded Applet for Konica Minolta V1.2.2
1 Introduction
The uniFLOW Embedded Applet for Konica Minolta is an applet designed for use on
Konica Minolta multifunction print devices.
uniFLOW Embedded Applet for Konica Minolta affords greater oversight of device
usage for business customers whom are environmentally aware and cost conscious,
allowing control and reduced wastage of paper, toner and energy, in the day to day
operation of their Konica Minolta devices.
No longer will piles of unwanted copies or print-jobs end up in the recycling bin when
users either forget the requested print, or decide it is no longer required once it has
been added to the print queue.
With uniFLOW Embedded Applet for Konica Minolta, users log into the native
application running on the Konica Minolta device and are presented with a list of their
print jobs stored on a central server. From here they are able to release jobs en masse
or individually, print and keep them for later, or simply delete them from the queue.
Built in tracking features can be utilized to monitor the jobs released, which can be
tracked by paper size, color and number of printed duplex or single sides. If required
jobs can be assigned prices, calculated dependent on pages, sides, size and color,
which can be presented to the user as they are choosing print jobs to be released from
the queue.
Sophisticated usage tracking features, prevention of unauthorized copy/prints and a
smooth intuitive user interface make uniFLOW Embedded Applet for Konica Minolta
the definitive choice for managing Konica Minolta multifunction devices.
2 Feature List
The following tables give an overview of the features available in the uniFLOW
Embedded Applet for Konica-Minolta.
Core functionality V1.2.2
1
uniFLOW Embedded Applet for Konica Minolta V1.2.2
PIN yes
Username/ password yes
Job code yes
• MiCard V3 Multi no
Anonymous login no
Card registration on device yes
Customizable login screen no
Device function restriction based on user no
login
Thumbnail preview no
Change finishing options before release no
Print shared jobs from archive no
2
uniFLOW Embedded Applet for Konica Minolta V1.2.2
Scan to mail no
3
uniFLOW Embedded Applet for Konica Minolta V1.2.2
4 Requirements
All referenced operating systems assume the latest service pack is installed.
4.2 uniFLOW
• uniFLOW V5.1 SR7 or higher
4
uniFLOW Embedded Applet for Konica Minolta V1.2.2
5
uniFLOW Embedded Applet for Konica Minolta V1.2.2
For printing with the uniFLOW Universal Driver it is mandatory that Anonymous
Printing is allowed in the Konica Minolta device settings. This is the default setting and
should not be changed.
For details on how to set this, please consult the Konica Minolta installation manual.
1. On the Security tab, navigate to PKI Settings > Device Certificate Setting. If an SSL
certificate is shown at this point, skip the following steps:
o Click New Registration, select Create and install a self-signed Certificate and
click OK.
6
uniFLOW Embedded Applet for Konica Minolta V1.2.2
o Fill in the fields with some values about your organization. The values have no
functional significance.
o For the Validity Period the maximum number of days offered is
recommended (usually 3650 = 10 years).
o Encryption Key Type can be left to the default values.
o Click OK. The certificate will be generated and your web browser will re-logon
to the web server under “https” mode. You may have to confirm an “invalid
certificate” in your browser.
• In case the website did not automatically re-logon with HTTPS
activated, activate SSL manually under Device Certificate Setting >
SSL Setting. Activate SSL for Administrator-Mode and User-Mode.
Furthermore, please activate every type of SSL versions and
encryption strengths.
• On some devices, an additional setting is visible with the title:
Action for Invalid Certificate.
In such case, on the Security tab under SSL/TLS Setting, click Action
for Invalid Certificate. If Continue is not already selected in the
drop-down list, select it and click OK.
7
uniFLOW Embedded Applet for Konica Minolta V1.2.2
In case you still experience SSL issues during enabling Device Lock on the Registration
Tool. Please check following:
1. On the Network tab click TCP Socket Setting.
2. Check if Use SSL/TLS is still enabled. If this is not the case, enable the TCP Socket
and again check the Use SSL/TLS setting.
3. Click OK. You may be asked to reboot your device.
If you change the TCP Socket settings, turn the main power of the device off and then
on to make the new settings take effect.
When Enhanced Security Mode is ON, Use SSL/TLS is enabled.
8
uniFLOW Embedded Applet for Konica Minolta V1.2.2
Disabling OpenAPI
If the OpenAPI password is unknown, it may be necessary to disable the OpenApi
authentication.
1. Make sure the MFP is idle (not running tasks such as copying, printing, scanning,
etc.).
2. Press the Utility/Counter button.
3. Touch option Administrator Settings.
4. Enter the Administrator PIN for the device and touch OK.
5. Touch option System Connection.
6. Touch option OpenAPI Settings.
7. Touch option Authentication.
8. Touch OFF.
9. Touch OK.
9
uniFLOW Embedded Applet for Konica Minolta V1.2.2
10
uniFLOW Embedded Applet for Konica Minolta V1.2.2
5. Enter the IP address of the server where the Konica Minolta Client is being
installed.
11
uniFLOW Embedded Applet for Konica Minolta V1.2.2
12
uniFLOW Embedded Applet for Konica Minolta V1.2.2
3. Enter the address of the server where the Konica Minolta Native UI Client is
running.
13
uniFLOW Embedded Applet for Konica Minolta V1.2.2
14
uniFLOW Embedded Applet for Konica Minolta V1.2.2
2. Select the correct Server IP Address of the server where this KM Native UI Client is
installed.
3. Enter MFP IP Address, Admin Password and click Get Application List.
15
uniFLOW Embedded Applet for Konica Minolta V1.2.2
4. If connection is successful, you should see the registered applications that were
previously registered on the device (if any).
16
uniFLOW Embedded Applet for Konica Minolta V1.2.2
17
uniFLOW Embedded Applet for Konica Minolta V1.2.2
18
uniFLOW Embedded Applet for Konica Minolta V1.2.2
19
uniFLOW Embedded Applet for Konica Minolta V1.2.2
2. Select the correct Server IP Address of the server where this KM Native UI Client is
installed.
3. Enter MFP IP Address, Admin Password and click Get Application List.
20
uniFLOW Embedded Applet for Konica Minolta V1.2.2
4. If connection is successful, you should see the registered applications that were
previously registered on the device (if any).
21
uniFLOW Embedded Applet for Konica Minolta V1.2.2
d. Personal Email in Scan to Me: When selected, the smtp email value from
uniFLOW identities will be populated in to Scan to Me on the device.
Otherwise: myself@uniflow will be used. This function is only supported with
device lock enabled.
22
uniFLOW Embedded Applet for Konica Minolta V1.2.2
10 Configuration in uniFLOW
Before you can use the uniFLOW Embedded Applet for Konica Minolta, you have to
configure the printer the applet has been installed on in uniFLOW.
To do so, go to uniFLOW Server Configuration > Printer / Scanner > Wizards, choose
Secure Print - Output Printer for Multi-Vendor and follow the on-screen instructions.
For uniFLOW versions lower than V5.4, you have to configure the printer manually.
For more information on how to do so, please refer to Advanced Configuration >
Embedded Applets > Konica Minolta in the uniFLOW User Manual:
uniFLOW Manual (https://nt-ware.com/helpredirect/?id=26051)
23
uniFLOW Embedded Applet for Konica Minolta V1.2.2
2. Enter your PIN Code to log in. You can press the Pin Code button to open the
on-screen keyboard which will allow you to enter your PIN Code. Once PIN has
been entered, press Login.
24
uniFLOW Embedded Applet for Konica Minolta V1.2.2
Depending on the configuration in uniFLOW, a login with Job Code is also possible.
For Job Code login, enter the received Job Code, then touch Login.
Job Code login does only accept numeric entries.
Job Code does not unlock the device. The Job Code button is
always shown, no matter which authentication method has been
pre-configured in uniFLOW.
3. Once the login has been successful, you will see the Secure Queue screen. Here
you can perform the main application functions.
If the Device Lock is enabled, the user will see the main menu after
login and they will need to start the application manually.
If Cost Center Selection has been enabled in the EAI settings of the
device in uniFLOW, the user will have to select a Cost Center before
getting access to their Secure Queue. Note that there is no Multi
Level Cost Center support for Konica Minolta devices available.
o List Update: Refreshes view of print queue and returns to top of list.
o Select All: Selects entire queue.
o Delete: Delete job from queue.
o Details: Shows details of the job like pages, paper format, color and price.
25
uniFLOW Embedded Applet for Konica Minolta V1.2.2
o Forward: Scroll.
4. Multiple jobs from multiple pages can be selected at one time by simply pressing
them on screen. Once a selection has been made, you can use the function
buttons.
5. Pressing Delete with a minimum of 1 job selected will take you to a confirmation
screen.
26
uniFLOW Embedded Applet for Konica Minolta V1.2.2
Here you can confirm your selection, simply press Delete to confirm you wish to
delete the jobs from the queue. Pressing Save will take you back to the print
queue.
6. Pressing Select All will select all jobs in the queue. You can deselect all jobs by
pressing Reset.
7. Finally, press Exit to logout.
27
uniFLOW Embedded Applet for Konica Minolta V1.2.2
4. Press the Start button to scan the document and send it to your email address.
28
uniFLOW Embedded Applet for Konica Minolta V1.2.2
2. Enter device IP address, administrator password and click Get Application List.
3. If connection is successful, you should see the registered applications in the list
box.
29
uniFLOW Embedded Applet for Konica Minolta V1.2.2
4. Select the application you wish to uninstall from the Applications list and click
Delete.
13 Troubleshooting
There are no known issues.
However, should you encounter a problem uninstall the application fully, restart the
machine and Install the Application using the instructions above for guidance.
How can I check which version of the uniFLOW Embedded Applet for Konica
Minolta is currently installed?
You can check the version of the applet currently installed on the device by pressing
the About button of the login screen on the device.
To check the currently installed version of the Konica Minolta client, do the following:
1. On the system, where the client is installed, navigate to Control Panel > Programs
and Features and find Konica Minolta Native UI Client in the list of installed
programs.
2. The version of the client is displayed in the Version tab.
30
uniFLOW Embedded Applet for Konica Minolta V1.2.2
When I press the on-screen Login button in the Konica Minolta embedded
application, the device panel shows “Connecting to server” for an extended
time. How can I fix this?
Please check the following:
Is the device’s network connection functional?
1. Is there a red cross error displayed in the uniFLOW Server Configuration interface
at Connections > Agents / Terminals > EAI > List view [device]> Licensed?
2. Also check the Connections > Agents/Terminals > EAI > Network Configuration
part for valid IP addresses and ports.
3. Try switching off the device for 5 seconds and switching it on again. This may
resolve some network connectivity issues.
4. Can the uniFLOW connect to the KM Client Service on port 2556?
5. You may need to check routers and firewalls, including the Windows software
firewall. A good way to test this is to telnet from uniFLOW server to the KM Native
UI Client Service IP address on port 2556 (telnet 1.2.3.4 2556).
6. Check the addendum within this manual for Konica Minolta for requirements on
certificate verification settings in the device’s web interface and verify that all
these requirements have been met. In particular:
o Check that Certificate Verification has been disabled in the Network →
OpenAPI section (“Do not request”/”Do not confirm”).
o Check that Certificate Verification in the Security section (on newer devices
only) has been set to OFF.
7. Does the device have the latest firmware installed? Connection problems may
occur with older firmware versions on some devices. Please check with your
Konica Minolta supplier for the version number of the latest firmware available
and compare with what you find in the device’s web interface.
8. What is the IP address of the KM Client service? When starting the KM Client
service, e.g. after a reboot or, in Windows, through Control Panel > Administrative
Tools > Services > KM Client Service, you will find a line like this in the log file
[app-path]/OpenAPISDK1.log.
Example:
2013/03/07_14:20:08:4170 T SDKBaseLibrary
xyz.xyz.xyz.xyzDevReqManager
CertificateFile set […….]
The IP address in the line will be the one that the Konica Minolta device uses to
contact the uniFLOW server. Please compare it with IP address which is stored in
[app-path] it should include same IP address value.To synchronize the values
please also, refer to Chapter 7 – Installation of Applet.
Please note: If you want it to use another address, e.g. if you have multiple
interfaces, please change and then update the option “Server IP address” in the
KM Application Registration Tool, which you will find within Chapter 7 –
Installation of Applet.
9. Check whether other MFP embedded or server applications might be interfering
with uniFLOW server.
10. If none of the above helps, we recommend using WireShark to capture a network
trace of packets transmitted by the MFP during the logon process. Make sure to
31
uniFLOW Embedded Applet for Konica Minolta V1.2.2
capture from a PC on the same LAN segment as the MFP with no routers/switches
in between. Send the trace as a PCAP file to support to help with diagnosing.
When I want to use scan to myself, predefined entry is not visible in the
address book on the device. How can I fix this?
In case you do not see registered uniFLOW E-mail address within the device address
book please enable the Scan to E-email setting in Network > E-mail Settings > E-mail
TX (SMTP).
32
uniFLOW Embedded Applet for Konica Minolta V1.2.2 Index
Index
C L
Checking Firmware Versions � 6 Log File � 32
Compatibility / Device Requirements � 5 Login Delay with Session Based Accounting � 5,
32
Configuration in uniFLOW � 4, 5, 23
Configuration of the Konica Minolta Device � 4,
N
6, 23
Network Communication Ports � 5, 32
D
P
Device Settings � 5, 6
Printing from the Secure Queue � 5, 24
Disclaimer � 7
R
F
Requirements � 4
Feature List � 5, 1
S
I
Scan to Email � 27
Installation of the Applet with Device Lock Config.
� 18 Symbols � 8
33
© Business I.T. Systems Ltd - 2011 - 2021