LEG9092
LEG9092
Description:
• GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization.
• Each computer or devices with Ethernet connectivity to GPS NTP3 Time Server, can adjust own
local time to worldwide atomic clock standard via the GPS Global positioning system. GPS time is
linked to USA NIST atomic cesium standard.
• In time server is built in NTP Ver.3 protocol (Network Time Protocol). It is platform independent of any
kind operation system.
• NTP3 Broadcasting supported
• SNMP traps output for UTC LOST FIX monitoring.
• Time Server has built in HTTP Web implementation, to visit actual status of GPS receiver, local time,
and server setup.
• Delivery included External GPS Receiver with active antenna built in waterproof case. Connection to
server through standard TP twisted pair cable up to 100m.
• Real Time Clock is implemented with Lithium backup battery CR2430 also. Built-in RTC safely
keeping the time/date when the GPS signal is lost.
• Time server is without AC/DC adaptor 12V/300mA shipped.
GPS DIN Wiring:
JUMPER
to default IP setup
RED LED
Flashing
on UTC FIX
error
BLUE LED
Flashing
PPS
Green LED
Ethernet Link
PPS pulse indicator
input GPS Message
Input
10BaseT
Ethernet
+ -
White Brown
Brown
DC Power Input
9..24V / 300mA
TWISTED Pairs
+ -
White Green
Green
DC Power GPS
Output Message
to External GPS
receiver PPS
TP Cable
4x Twisted pairs
to GPS receiver
Mounted LEDs:
• Green LED near the ethernet RJ45 connector indicates ethernet connection.
• RED LED if flashing, inform about UTC FIX Error. Server is not synchronized to GPS system.
• Blue LED must flashing in 1sec interval, it is copy of the PPS pulse signal from external receiver
Red with White-Red pair can be used for positive power line.
Blue and White-blue for negative power.
FIX LED
POWER
LED FUSE
500mA/T
DC Power
9..35V
DATA PPS - +
PPS LED
Blue+WhiteBlue
Red+WhiteRed
Twisted
Pair
White-Brown
White-Green
Brown
Green
Installation steps:
• Short the jumper on PCB. It will cause default Ethernet Setup to below table values:
IP address: 192.168.0.16
Subnet Mask: 255.255.255.0
Default Gateway: Not implemented = 0.0.0.0
Authentication name: Gps
Password: 123456
• Connect Time Server to DC power source, with standard AC/DC adapter. Required is 9..24V DC
voltage with max current consumption 300mA.
Note: Time server is protected for cross voltage, but not for high voltage.
First time we strongly suggested to setup new password with link to Password Setup:
Before new password window setup, old password will be requested;
in the default setup is 123456. Password setup window will be displayed:
Community name, Device name and Location are used in SNMP trap messages.
Submit values with Submit button.
From main window Click to link Network Setup:
on setup window user can check actual network values, and change any value.
• Broadcasting Interval:
Time period in seconds, when Server sends the NTP3 broadcast message to broadcast IP
address.
• SNMP Trap IP: IP address of computer to which will be sending SNMP traps. Server produce
SNMP trap each time the UTC Fix is lost.
System status window
Anytime it is possible refresh this web page to obtain new values pressing Browser RELOAD button.
NTP protocol:
Time server has built in NTP Ver 3 protocol. All platforms such as UNIX, WINDOWS NT,XP,2000 supports
NTP protocol.
In windows XP/2000 user can try to setup local time in Time/Date window.
On Internet Time Card, enter IP address to time server:
SNMP TRAP description
GPS Time server produce SNMP trap message on every UTC FIX lost.
Status Byte:
Bit Description
0 1 = PPS pulse from GPS receiver missing , GPS receiver is not connected
Max period of SNMP trap is 1sec in according to every 1second GPS sends Data message about UTC FIX
status and number of satellites measurements.
Community default name is ‘public’, and can be modified by user from time server web page.
OID description;