0% found this document useful (0 votes)
319 views2 pages

Uncertainty. of Mean Rib Area

This document summarizes the uncertainty measurement of the mean rib area test parameter for a sample of reinforcement steel. It details the equipment used, calculations of uncertainty from multiple measurements, and an uncertainty budget. The combined relative standard uncertainty is 0.016 and the expanded uncertainty at a 95% confidence level is 0.04448 mm2/mm. For the measured mean value of 2.3 mm2/mm, the expanded uncertainty is 0.10 mm2/mm.

Uploaded by

Santosh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
319 views2 pages

Uncertainty. of Mean Rib Area

This document summarizes the uncertainty measurement of the mean rib area test parameter for a sample of reinforcement steel. It details the equipment used, calculations of uncertainty from multiple measurements, and an uncertainty budget. The combined relative standard uncertainty is 0.016 and the expanded uncertainty at a 95% confidence level is 0.04448 mm2/mm. For the measured mean value of 2.3 mm2/mm, the expanded uncertainty is 0.10 mm2/mm.

Uploaded by

Santosh Kumar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Lab Name Doc. No.: …..

L/FF/22
Uncertainty measurement of test parameters (Mechanical tests) as per NABL 141 guidelines

Product: Reainforce Steel 12 mm


Test parameter: Mean Rib Area

Equipment/ Machine used for measurement


S. No. Equip/ Machine Parameter Range/ Size (M) Unit Uc Unit
1 Vernier Caliper Length 300 mm 0.0092 mm

CALCULATIONS

Uncert. Source of Type Observation Unit Deviation Unit (Ai-Ᾱ)² UnitStd. deviation σ Unit
U uncertainty (Ai-Ᾱ) = √∑(Ai-Ᾱ)²
U1 Repeatability A1 = 2.40 mm2/mm 0.1 0.01 √ n-1
A2 = 2.28 -0.02 0.0004 = 0.083 mm2/mm
A3 = 2.25 -0.05 0.0025 Std Uncertainty u1
A4 = 2.37 0.07 0.0049 = σ/ √n
A A5 = 2.20 -0.1 0.01 = 0.0371 mm2/mm
2.3 mm2/ ∑ = 0.0278 mm2/ Relative Uncertainty
Ᾱ= mm mm
n= 5 = u1/Ᾱ
= 0.0161
U2 Vernier B Length Standard Uncertainty u2 = Uc/2 Relative U2
Caliper ± Uc from Cal Cert = u2
M 300 mm = 0.0092 mm = 0.0046 mm M
at k = 2 = 0

Uncertainty Budget
Uncert. Source of Estimate Limits Type F Std. Sensi-tivity Uncert. Divisor Relative DOF
Uncertainty Value Uncertainty co- Contribu- (M) Uncertainty
efficient tion Contribu-tion

U1 Repeatability 0.083 0.0415 A √5 0.0371 1 0.0371 2.3 0.0161 4


U2 Vernier 0.0092 0.0046 B 2 0.0046 1 0.0046 300 0 ∞
Caliper

Combined Rel. Std. Uc = √ {(U1)² + (U2)² + (U3)² + (U4)² + (U5)² + (U6)²+ (U7)²}

Uc = 0.016

Degree of Freedom (DOF) = 4

Coverage factor K at 95% Confidence Level = 2.78

Expanded Uncertainty UM = 0.04448

Lab Technician Page 1 of 2 Technical Manager


Lab Name Doc. No.: …..L/FF/22
Uncertainty measurement of test parameters (Mechanical tests) as per NABL 141 guidelines

Product: Reainforce Steel 12 mm


Test parameter: Mean Rib Area

At measured Mean Value 2.3 mm2/mm UM = 0.10 mm2/mm

Lab Technician Page 2 of 2 Technical Manager