MSDS Ultrion™ 71223
MSDS Ultrion™ 71223
1907/2006
ULTRION™ 71223
1.2 Relevant identified uses of the substance or mixture and uses advised against:
Poison Information Centre : For medical professionals only: 0344 892 0111 Poison Control
telephone number Center
Hazard pictograms :
1 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
3.2 Mixtures
Hazardous components
Chemical Name CAS-No. Classification Concentration:
EC-No. (REGULATION (EC) No 1272/2008) [%]
REACH No.
Aluminum Chloride 39290-78-3 Corrosive to metals Category 1; H290 20 - < 25
254-400-7 Serious eye damage Category 1; H318
Hydroxide Sulphate
01-2119531563-43
For the full text of the H-Statements mentioned in this Section, see Section 16.
In case of skin contact : Wash off with soap and plenty of water.
Get medical attention if symptoms occur.
In case of eye contact : Rinse immediately with plenty of water, also under the eyelids,
for at least 15 minutes.
Remove contact lenses, if present and easy to do. Continue
rinsing.
Get medical attention immediately.
Protection of first-aiders : In event of emergency assess the danger before taking action.
Do not put yourself at risk of injury. If in doubt, contact
emergency responders.Use personal protective equipment as
2 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
required.
4.2 Most important symptoms and effects, both acute and delayed
See Section 11 for more detailed information on health effects and symptoms.
Further information : Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations. In the
event of fire and/or explosion do not breathe fumes.
Advice for emergency : If specialised clothing is required to deal with the spillage, take
responders note of any information in Section 8 on suitable and unsuitable
materials.
3 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Hygiene measures : Handle in accordance with good industrial hygiene and safety
practice. Remove and wash contaminated clothing before re-
use. Wash face, hands and any exposed skin thoroughly after
handling. Provide suitable facilities for quick drenching or
flushing of the eyes and body in case of contact or splash
hazard.
Storage temperature : 0 °C to 30 °C
4 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
DNEL
Aluminum Chloride Hydroxide : End Use: Workers
Sulphate Exposure routes: Inhalation
Potential health effects: Long-term systemic effects
Value: 40.1 mg/m3
PNEC
Aluminum Chloride Hydroxide : Fresh water
Sulphate Value: 0.0003 mg/l
Marine water
Value: 0.00003 mg/l
The Personal Protective Equipment (PPE) recommendations provided above have been made in good faith
based on typical expected conditions of use. PPE selection should always be completed in conjunction with
a proper risk assessment and in accordance with a PPE management program.
5 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Colour : colourless
Odour : odourless
Flash point :
does not flash
pH : 2, 100 %
Viscosity
Viscosity, dynamic : no data available
Viscosity, kinematic : < 80 mm2/s (20 °C)
no data available
6 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
10.1 Reactivity
No dangerous reaction known under conditions of normal use.
10.2 Chemical stability
Stable under normal conditions.
10.3 Possibility of hazardous reactions
Hazardous reactions : No dangerous reaction known under conditions of normal use.
Toxicity
Product
Acute oral toxicity : There is no data available for this product.
Acute inhalation toxicity : There is no data available for this product.
Acute dermal toxicity : There is no data available for this product.
Skin corrosion/irritation : There is no data available for this product.
7 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Components
Acute oral toxicity : Aluminum Chloride Hydroxide Sulphate
LD50 Oral Rat: 3,450 mg/kg
Chronic Exposure : Health injuries are not known or expected under normal
use.
12.1 Toxicity
Product
Environmental Effects : This product has no known ecotoxicological effects.
Components
8 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Product
Biodegradability : Greater than 95% of this product consists of inorganic
substances for which a biodegradation value is not
applicable.
Result: Biodegradable
Components
Biodegradability : Aluminum Chloride Hydroxide Sulphate
Result: Not applicable - inorganic
Product
Bioaccumulation : This preparation or material is not expected to bioaccumulate.
Product
The portion in water is expected to be soluble or dispersible.
Product
Assessment : This substance/mixture contains no components considered
to be either persistent, bioaccumulative and toxic (PBT), or
very persistent and very bioaccumulative (vPvB) at levels of
0.1% or higher.
Dispose of in accordance with the European Directives on waste and hazardous waste.Waste codes should
be assigned by the user, preferably in discussion with the waste disposal authorities.
9 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Guidance for Waste Code : Inorganic wastes containing dangerous substances. If this
selection product is used in any further processes, the final user must
redefine and assign the most appropriate European Waste
Catalogue Code. It is the responsibility of the waste generator
to determine the toxicity and physical properties of the
material generated to determine the proper waste
identification and disposal methods in compliance with
applicable European (EU Directive 2008/98/EC) and local
regulations.
The shipper/consignor/sender is responsible to ensure that the packaging, labeling, and markings are in
compliance with the selected mode of transport.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture:
10 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
CANADA
The substances in this preparation are listed on the Domestic Substances List (DSL), are exempt, or have
been reported in accordance with the New Substances Notification Regulations.
A Chemical Safety Assessment has been carried out for some of the substances in this mixture.
ADN - European Agreement concerning the International Carriage of Dangerous Goods by Inland
Waterways; ADR - European Agreement concerning the International Carriage of Dangerous Goods by
Road; AIIC - Australian Inventory of Industrial Chemicals; ASTM - American Society for the Testing of
Materials; bw - Body weight; CLP - Classification Labelling Packaging Regulation; Regulation (EC) No
1272/2008; CMR - Carcinogen, Mutagen or Reproductive Toxicant; DIN - Standard of the German Institute
for Standardisation; DSL - Domestic Substances List (Canada); ECHA - European Chemicals Agency; EC-
Number - European Community number; ECx - Concentration associated with x% response; ELx - Loading
rate associated with x% response; EmS - Emergency Schedule; ENCS - Existing and New Chemical
Substances (Japan); ErCx - Concentration associated with x% growth rate response; GHS - Globally
Harmonized System; GLP - Good Laboratory Practice; IARC - International Agency for Research on
Cancer; IATA - International Air Transport Association; IBC - International Code for the Construction and
Equipment of Ships carrying Dangerous Chemicals in Bulk; IC50 - Half maximal inhibitory concentration;
ICAO - International Civil Aviation Organization; IECSC - Inventory of Existing Chemical Substances in
China; IMDG - International Maritime Dangerous Goods; IMO - International Maritime Organization; ISHL -
Industrial Safety and Health Law (Japan); ISO - International Organisation for Standardization; KECI -
Korea Existing Chemicals Inventory; LC50 - Lethal Concentration to 50 % of a test population; LD50 -
11 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Lethal Dose to 50% of a test population (Median Lethal Dose); MARPOL - International Convention for the
Prevention of Pollution from Ships; n.o.s. - Not Otherwise Specified; NO(A)EC - No Observed (Adverse)
Effect Concentration; NO(A)EL - No Observed (Adverse) Effect Level; NOELR - No Observable Effect
Loading Rate; NZIoC - New Zealand Inventory of Chemicals; OECD - Organization for Economic Co-
operation and Development; OPPTS - Office of Chemical Safety and Pollution Prevention; PBT - Persistent,
Bioaccumulative and Toxic substance; PICCS - Philippines Inventory of Chemicals and Chemical
Substances; (Q)SAR - (Quantitative) Structure Activity Relationship; REACH - Regulation (EC) No
1907/2006 of the European Parliament and of the Council concerning the Registration, Evaluation,
Authorisation and Restriction of Chemicals; RID - Regulations concerning the International Carriage of
Dangerous Goods by Rail; SADT - Self-Accelerating Decomposition Temperature; SDS - Safety Data
Sheet; SVHC - Substance of Very High Concern; TCSI - Taiwan Chemical Substance Inventory; TECI -
Thailand Existing Chemicals Inventory; TRGS - Technical Rule for Hazardous Substances; TSCA - Toxic
Substances Control Act (United States); UN - United Nations; vPvB - Very Persistent and Very
Bioaccumulative
Further information
Sources of key data used to : IARC Monographs on the Evaluation of the Carcinogenic Risk
compile the Safety Data of Chemicals to Man, Geneva: World Health Organization,
Sheet International Agency for Research on Cancer.
Numbers quoted in the MSDS are given in the format: 1,000,000 = 1 million and 1,000 = 1 thousand. 0.1 = 1
tenth and 0.001 = 1 thousandth
REVISED INFORMATION: Significant changes to regulatory or health information for this revision is
indicated by a bar in the left-hand margin of the SDS.
The information provided in this Safety Data Sheet is correct to the best of our knowledge, information
and belief at the date of its publication. The information given is designed only as a guidance for safe
handling, use, processing, storage, transportation, disposal and release and is not to be considered a
warranty or quality specification. The information relates only to the specific material designated and
may not be valid for such material used in combination with any other materials or in any process, unless
specified in the text.
Life Cycle Stage : Industrial uses: Uses of substances as such or in preparations at industrial
sites
12 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
Process category : PROC4 Use in batch and other process (synthesis) where opportunity
for exposure arises
13 / 14
SAFETY DATA SHEET according to Regulation (EC) No. 1907/2006
ULTRION™ 71223
14 / 14