0% found this document useful (0 votes)
108 views1 page

Clarifier Design Specs for Engineers

This document provides design data for circular mechanical clarifiers from Pollution Control Systems, Inc. It includes clarifier drawings, models, design flows, tank dimensions, inlet/outlet pipe sizes, and sludge handling details. Clarifier sizes range from 8 to 34 feet in diameter and are designed to handle flows from 18,850 to 351,860 gallons per day based on surface settling rates and a peak flow factor.

Uploaded by

Ramki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
108 views1 page

Clarifier Design Specs for Engineers

This document provides design data for circular mechanical clarifiers from Pollution Control Systems, Inc. It includes clarifier drawings, models, design flows, tank dimensions, inlet/outlet pipe sizes, and sludge handling details. Clarifier sizes range from 8 to 34 feet in diameter and are designed to handle flows from 18,850 to 351,860 gallons per day based on surface settling rates and a peak flow factor.

Uploaded by

Ramki
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

POLLUTION CONTROL SYSTEMS, INC.

CIRCULAR MECHANICAL CLARIFIER DESIGN DATA

Clarifier Clarifier Clarifer Clarifer Tank Tank Side Concrete Center Inlet Stilling Inlet Pipe Outlet Pipe Scum Pipe Sludge Pipe Sludge Pipe Sludge Well
Drawing Model Design Volume Dia. Water Depth Floor Height Sump Dia. Well Dia. Size Dia. Size Dia. Size Dia. Size Dia. CL Height Height
Number Number Flow Gallons Dim. -A- Dim. -B- Dim. -C- Dim. -D- Dim. -E- Dim. -F- Dim. -G- Dim. -H- Dim. -J- Dim. -K- Dim. -L-
Note #1
CMC-CAT1 CMC-8 18,850 3,321 8'-0" 8'-8 1/2" 9 1/2" 20" 2'-0" 6" 6" 2" 3" 4" 7 1/4"

CMC-CAT1 CMC-10 30,160 5,157 10'-0" 8'-7 1/2" 10 1/2" 20" 2'-0" 6" 6" 2" 3" 4" 7 1/4"

CMC-CAT1 CMC-12 42,400 7,380 12'-0" 8'-6 1/2" 11 1/2" 20" 3'-0" 6" 6" 2" 3" 4" 7 1/4"

CMC-CAT2 CMC14 58,750 9,586 14'-0" 8'-1 1/4" 1'-4 3/4" 20" 3'-0" 6" 6" 3" 4" 6" 10 5/8"

CMC-CAT2 CMC-16 77,600 12,427 16'-0" 8'-0 1/4" 1'-5 3/4" 20" 3'-0" 8" 6" 3" 4" 6" 10 5/8"
CMC-CAT2 CMC-18 98,960 15,571 18'-0" 7'-11 1/4" 1'-6 3/4" 20" 3'-0" 8" 6" 3" 4" 6" 10 5/8"
CMC-CAT3 CMC-20 120,640 19,091 20'-0" 7'-10 1/4" 1'-7 3/4" 20" 4'-0" 10" 8" 3" 6" 6" 10 5/8"

CMC-CAT3 CMC-22 147,030 22,963 22'-0" 7'-9 1/4" 1'-8 3/4" 20" 4'-0" 10" 8" 3'' 6" 6" 10 5/8"
CMC-CAT3 CMC-24 173,100 27,288 24'-0" 7'-8 1/4" 1'-9 3/4" 20" 5'-0" 12" 10" 3" 6" 6" 10 5/8"
CMC-CAT3 CMC-26 204,515 31,650 26'-0" 7'-7 1/4" 1'-10 3/4" 20" 5'-0" 12" 10" 3" 6" 6" 10 5/8"

CMC-CAT3 CMC-28 238,444 36,423 28'-0" 7'-6 1/4" 1'-11 3/4" 20" 5'-0" 12" 10" 3" 6" 6" 10 5/8"

CMC-CAT3 CMC-30 271,435 40,657 30'-0" 7'-3 1/4" 2'-2 3/4" 24" 6'-0" 14" 10" 3" 8" 7 1/2" 12 1/2"
CMC-CAT3 CMC-32 310,390 45,961 32'-0" 7'-2 1/4" 2'-3 3/4" 24" 6'-0" 14" 10" 3" 8" 7 1/2" 12 1/2"
CMC-CAT3 CMC-34 351,860 51,470 34'-0" 7'-1 1/4" 2'-4 3/4" 24" 6'-0" 16" 10" 3" 8" 7 1/2" 12 1/2"

1. Design Flow rates based on surface settling rate of 1000 gpd/sq.ft.with a peak flow factor of 2.5