1. Product Overview
This series of radar level meter adopted 26G high frequency radar sensor, the maximum
measurement range can reach up to 70 meters. Antenna is optimized further processing,
the new fast microprocessors have higher speed and efficiency can be done signal
analysis, the instrumentation can be used for reactor, solid silo and very complex
measurement environment.
Principle
Radar level transmitter antenna microwave pulse is narrow, the downward transmission
antenna. Microwave exposure to the medium surface is reflected back again by the
antenna system receives, sends the signal to the electronic circuit automatically
converted into level signals (because the microwave propagation speed, electromagnetic
wave to reach the target and the reflected back to the receiver this time is almost
instantaneous).
A Range set
B Low adjustment
C High
D Blind area
Datum measurement: Screw thread bottom or the sealing surface of the flange.
Note: Make sure the radar level meter the highest level cannot enter the measuring blind
area (Figure D shown below).
2
High signal-to-noise ratio, the level fluctuation state can obtain better
performance.
High frequency, measurement of solid and low dielectric constant of the best
choice.
2. Product Introduction
QTRD91
Application: All kinds of corrosive liquid
Measuring Range:10 meters
Process Connection: Thread, Flange
Medium Temperature: -40℃ ~ 120℃
Process Pressure: -0.1~0.3 MPa
Accuracy: ± 5mm
Protection Grade: IP67
Frequency Range: 26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade: Exia ⅡC T6 Ga
QTRD92
Application:Liquid
Measuring Range:30 meters
Process Connection:Thread, Flange
Medium Temperature:-40℃ ~ 150℃
Process Pressure:-0.1 ~ 4.0 MPa
Accuracy: ± 3mm
Protection Grade:IP67
Frequency Range: 26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade: Exia ⅡC T6 Ga
QTRD93
Application:Solid material, Strong dust
Measuring Range: 70 meters
Process Connection:Universal Flange
Medium Temperature: -40℃ ~ 250℃
Process Pressure: -0.1 ~ 0.1 MPa
Protection Grade: IP67
Accuracy: ± 15mm
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga
3
QTRD94
Application:Solid material, Strong dust,
Measuring Range:70 meters
Process Connection:Universal Flange
Medium Temperature: -40℃ ~ 250℃
Process Pressure:-0.1 ~ 0.1MPa
Accuracy: ± 15mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga
QTRD95
Application:Solid particles, Powder
Measuring Range:30 meters
Process Connection:Thread, Flange
Medium Temperature:-40℃ ~ 250℃
Process Pressure:-0.1 ~ 4.0MPa
Accuracy:± 10mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga
QTRD96
Application:Hygienic liquid storage,
Corrosive container
Measuring Range:20 meters
Process Connection:Flange
Medium Temperature:-40℃ ~ 150℃
Process Pressure:-0.1 ~ 4.0MPa
Accuracy:± 3mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga
4
Appearance size:
QTRD91
QTRD92
QTRD93
5
QTRD94
QTRD95
QTRD96
6
Flange type:
3. Technical Parameters
Output parameters
The output signal (4 ~ 20) mA/RS485
Communication protocol HART
Resolution 1.6u A
Fault signal Constant current output; 20. 5mA
22mA
3.9mA
The integral time (0 ~ 50) s, adjustable
7
The maximum distance measurement 70 meters
Display resolution 1 mm
Pressure Max.4MPa
Seismic Mechanical vibration l0m/s², (10 ~ 150) Hz
8
4. Product Model Selection
QTRD91
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Antenna Type / Material / Temperature
F Sealing horn / PTEE / -40... 120 ℃
Process Connection / Material
G Thread G1½″ A
N Thread 1½″ NPT
A Flange DN50 /PP
B Flange DN80 /PP
C Flange DN100 /PP
Y Special Custom-tailor
The Outlet Pipe Length of the Container
A Outlet pipe 100mm
B Outlet pipe 200mm
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304 / IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
9
QTRD92
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
A Flange DN50 / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
Y Special Custom-tailor
Antenna Type / Material
A Horn Antenna Φ46mm / Stainless Steel 304
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
Y Special Custom-tailor
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
10
QTRD93
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
D Horn Antenna Φ121mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
11
QTRD94
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ196mm / Stainless Steel 304
C Horn Antenna Φ242mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
12
QTRD95
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
D Horn Antenna Φ121mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
13
QTRD96
License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ46mm / Stainless Steel 304
C Horn Antenna Φ76mm / Stainless Steel 304
D Horn Antenna Φ96mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without
14