0% found this document useful (0 votes)
68 views

26G Radar Level Meter

The document provides information on the QTRD 90 Series Radar Level Meter, including: - It uses 26GHz radar sensors and has a maximum range of 70 meters. It is suitable for reactors, silos, and complex environments. - It works by transmitting microwave pulses that reflect off the medium surface and return to the antenna. - It comes in 6 models (QTRD91-96) with different temperature ranges, pressures, accuracies, and connections suitable for liquids, solids, powders, and hygienic storage. - It has a 4-20mA output, HART communication, IP67 rating, and optional explosion proof ratings. Model selection depends on options

Uploaded by

ilopera1971
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

26G Radar Level Meter

The document provides information on the QTRD 90 Series Radar Level Meter, including: - It uses 26GHz radar sensors and has a maximum range of 70 meters. It is suitable for reactors, silos, and complex environments. - It works by transmitting microwave pulses that reflect off the medium surface and return to the antenna. - It comes in 6 models (QTRD91-96) with different temperature ranges, pressures, accuracies, and connections suitable for liquids, solids, powders, and hygienic storage. - It has a 4-20mA output, HART communication, IP67 rating, and optional explosion proof ratings. Model selection depends on options

Uploaded by

ilopera1971
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

QTRD 90 Series

Radar Level Meter

Catalogue

1
26G Radar Level Meter

1. Product Overview
This series of radar level meter adopted 26G high frequency radar sensor, the maximum
measurement range can reach up to 70 meters. Antenna is optimized further processing,
the new fast microprocessors have higher speed and efficiency can be done signal
analysis, the instrumentation can be used for reactor, solid silo and very complex
measurement environment.

 Principle

Radar level transmitter antenna microwave pulse is narrow, the downward transmission
antenna. Microwave exposure to the medium surface is reflected back again by the
antenna system receives, sends the signal to the electronic circuit automatically
converted into level signals (because the microwave propagation speed, electromagnetic
wave to reach the target and the reflected back to the receiver this time is almost
instantaneous).

A Range set

B Low adjustment

C High

D Blind area

Datum measurement: Screw thread bottom or the sealing surface of the flange.
Note: Make sure the radar level meter the highest level cannot enter the measuring blind
area (Figure D shown below).

 The characteristics of 26G radar level meter:


 Small antenna size, easy to install; Non-contact radar, no wear, no pollution.
 Almost no corrosion, bubble effect; almost not affected by water vapor in the
atmosphere, the temperature and pressure changes.
 Serious dust environment on the high level meter work has little effect.
 A shorter wavelength, the reflection of solid surface inclination is better.
 Beam angle is small, the energy is concentrated, can enhance the ability of echo
and to avoid interference.
 The measuring range is smaller, for a measurement will yield good results.

2
 High signal-to-noise ratio, the level fluctuation state can obtain better
performance.
 High frequency, measurement of solid and low dielectric constant of the best
choice.

2. Product Introduction

QTRD91
Application: All kinds of corrosive liquid
Measuring Range:10 meters
Process Connection: Thread, Flange
Medium Temperature: -40℃ ~ 120℃
Process Pressure: -0.1~0.3 MPa
Accuracy: ± 5mm
Protection Grade: IP67
Frequency Range: 26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade: Exia ⅡC T6 Ga

QTRD92
Application:Liquid
Measuring Range:30 meters
Process Connection:Thread, Flange
Medium Temperature:-40℃ ~ 150℃
Process Pressure:-0.1 ~ 4.0 MPa
Accuracy: ± 3mm
Protection Grade:IP67
Frequency Range: 26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade: Exia ⅡC T6 Ga

QTRD93
Application:Solid material, Strong dust
Measuring Range: 70 meters
Process Connection:Universal Flange
Medium Temperature: -40℃ ~ 250℃
Process Pressure: -0.1 ~ 0.1 MPa
Protection Grade: IP67
Accuracy: ± 15mm
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga

3
QTRD94
Application:Solid material, Strong dust,
Measuring Range:70 meters
Process Connection:Universal Flange
Medium Temperature: -40℃ ~ 250℃
Process Pressure:-0.1 ~ 0.1MPa
Accuracy: ± 15mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga

QTRD95
Application:Solid particles, Powder
Measuring Range:30 meters
Process Connection:Thread, Flange
Medium Temperature:-40℃ ~ 250℃
Process Pressure:-0.1 ~ 4.0MPa
Accuracy:± 10mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga

QTRD96
Application:Hygienic liquid storage,
Corrosive container
Measuring Range:20 meters
Process Connection:Flange
Medium Temperature:-40℃ ~ 150℃
Process Pressure:-0.1 ~ 4.0MPa
Accuracy:± 3mm
Protection Grade:IP67
Frequency Range:26GHz
Signal Output:4... 20mA/HART (Two-wire / Four)
RS485/ Modbus
Explosion-proof Grade:Exia ⅡC T6 Ga

4
 Appearance size:
QTRD91

QTRD92

QTRD93

5
QTRD94

QTRD95

QTRD96

6
 Flange type:

3. Technical Parameters

The outer shell


The seal between the shell and the shell cover Silicone rubber
Casing window Polycarbonate
The ground terminal Stainless steel

The power supply voltage


Two wire system
The standard type (16 ~ 26) V DC
Intrinsically safe (21.6 ~ 26.4) V DC
Power dissipation max 22.5mA / 1W
Allowable ripple
- <100Hz Uss<lV
- (100~100K) Hz Uss<l0mV

The cable parameters


Cable entrance / plug One M20xl.5 cable entrance
One blind plug
Terminal Conductor cross section 1.0mm²

Output parameters
The output signal (4 ~ 20) mA/RS485
Communication protocol HART
Resolution 1.6u A
Fault signal Constant current output; 20. 5mA
22mA
3.9mA
The integral time (0 ~ 50) s, adjustable

Blind area the ends of the antenna

7
The maximum distance measurement 70 meters

Microwave frequency 26GHz

Communication interface HART communication protocol

The measurement interval about 1 second (depending on the parameter settings)

Adjust the time about 1 second (depending on the parameter settings)

Display resolution 1 mm

Working storage and transportation temperature (-40~100) ℃

Process temperature (the temperature of the antenna part) (-40~250)℃

Pressure Max.4MPa
Seismic Mechanical vibration l0m/s², (10 ~ 150) Hz

8
4. Product Model Selection

 QTRD91

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Antenna Type / Material / Temperature
F Sealing horn / PTEE / -40... 120 ℃
Process Connection / Material
G Thread G1½″ A
N Thread 1½″ NPT
A Flange DN50 /PP
B Flange DN80 /PP
C Flange DN100 /PP
Y Special Custom-tailor
The Outlet Pipe Length of the Container
A Outlet pipe 100mm
B Outlet pipe 200mm
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304 / IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

9
 QTRD92

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
A Flange DN50 / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
Y Special Custom-tailor
Antenna Type / Material
A Horn Antenna Φ46mm / Stainless Steel 304
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
Y Special Custom-tailor
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

10
 QTRD93

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
D Horn Antenna Φ121mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

11
 QTRD94

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ196mm / Stainless Steel 304
C Horn Antenna Φ242mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

12
 QTRD95

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
G Thread G1½″A / Stainless Steel 304
N Thread 1½″ NPT / Stainless Steel 304
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
M Flange DN80 / Cardan joint ( Nickel plated carbon steel )
K Flange DN100 / Cardan joint ( Nickel plated carbon steel )
T Flange DN125 / Cardan joint ( Nickel plated carbon steel )
Z Flange DN150 / Cardan joint ( Nickel plated carbon steel )
W Flange DN200 / Cardan joint ( Nickel plated carbon steel )
V Flange DN250 / Cardan joint ( Nickel plated carbon steel )
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ76mm / Stainless Steel 304
C Horn Antenna Φ96mm / Stainless Steel 304
D Horn Antenna Φ121mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

13
 QTRD96

License
P Standard (Non-explosion-proof)
I Intrinsically safe (Exia IIC T6 Ga)
G Intrinsically safe type, Flameproof (Exd (ia) IIC T6 Ga)
Process Connection / Material
B Flange DN80 / Stainless Steel 304
C Flange DN100 / Stainless Steel 304
D Flange DN125 / Stainless Steel 304
E Flange DN150 / Stainless Steel 304
F Flange DN200 / Stainless Steel 304
H Flange DN250 / Stainless Steel 304
Y Special Custom-tailor
Antenna Type / Material
B Horn Antenna Φ46mm / Stainless Steel 304
C Horn Antenna Φ76mm / Stainless Steel 304
D Horn Antenna Φ96mm / Stainless Steel 304
Seal Up / Process Temperature
V Viton / (-40~150) ℃
K Kalrez / (-40~250) ℃
The Electronic Unit
2 (4~20) mA / 24V DC / Two wire system
3 (4~20) mA / 24V DC / HART two wire system
4 (4~20) mA / 220V AC / Four wire system
5 RS485 / Modbus
Shell / Protection Grade
L Aluminum / IP67
G Stainless Steel 304L/ IP67
Cable Line
M M 20x1.5
N ½″ NPT
Field Display/The Programmer
A With
X Without

14