Guide For RDS-PS
Guide For RDS-PS
Introduction
This A3 booklet presents the new common language for the Energy Power Sector, RDS-PS, and at the same time
compare it with former RDS for Power Plants (PP) where relevant.
There is a significant shift in mindset, that you must be aware of to understand the new PS edition: The old ISO/TS
81346-10 (2015) are dealing with Power Plants (PP) where focus are on coding principles, to the new generic Power
Systems (PS) where focus are on systems and system elements, which then are designated with RDS.
The new open standard, ISO 81346-10 (2022), known as RDS-PS, is now an International Standard (IS). Get started
and spend some time to familiarize yourself with the differences between old PP and new PS in this document.
On the following pages we have drawn the line so you can compare old PP (left side) and new PS (right side).
We hope that you will find this new document useful and look forward to seeing how the community uses this new
approach of systems thinking to their benefit. Comments and feedback are most welcome!
Copyright© notice: Please feel free to use this document and it’s content as you wish, as long as you put a reference to
www.81346.com along.
Best regards,
Knowledge Center of Reference Designations
RDS 81346 Technique ApS
Table of contents 2
2022-07-07 RDS 81346 Technique ApS
RDS Power Systems Guide
QA001 Circuit-breaker VGB-B 102 =HD1 Supply system for electrical energy 2
Information in designation code: Information in designation code: 1: RDS 81346-10 table AA.1: Power systems
2: RDS 81346-10 table AA.2: Technical systems
“Circuit breaker, that is part of “Circuit breaker 1 in 3: RDS 81346-2 table 3: Component systems
Medium voltage electrical supply system for safety services, voltage level 1, in an Electrical auxiliary electrical energy supply system 1 in
power supply system, in
the electrical power transportation system”
Main system T1”
RDS PS Syntax 3
2022-07-07 RDS 81346 Technique ApS
RDS Power Systems Guide = Function aspect
% Type aspect
RDS-Power Plants (PP) RDS-Power Systems (PS) #
Operation aspect + Space aspect
Aspects are used to specify the different abstraction level of Aspects are used to represent different viewpoints of object - Product aspect
systems and equipment occurrences
RDS-PS can only designate the occurrence of an object and never
the individual.
Unambiguous function Ambiguous product Unambiguous function
designation designation designation
(23 characters) =C01 MDK51 GP001 -MA01 XD01 (17 characters) =A1 =HB1 =MAA1 =XDA1 = Function aspect
Reference
designation set
Unambiguous equipment designation (12 characters) -D1 -HD1 -XDA1
Equipment designation meaning:
Generator system C01, gear oil conveyance, drive motor 1, connection point 1
Unambiguous product
- Product aspect
designation
Equipment in RDS-PP represents the individual component and are identified
by product number, settings, barcodes etc.
Function aspect meaning:
Wind turbine generator system, lubrication system, motor system,
It is important to note the product aspect designation is in itself unambiguous. low voltage connection cable.
There is only a need to express two designations as a reference designation
set when the two aspects product and functional are implemented by the Product aspect meaning:
same object. Support generator system, power transportation system, cable system.
Code Structure
In focus In focus
=A1=KE1=GPB1=MAA1
Code vs structure 5
2022-07-07 RDS 81346 Technique ApS
RDS Power Systems Guide
The 3 letter classification scheme in VGB-B 101 contains very specific codes, that classifies different The new 81346-1 has introduced the type aspect which makes it
types of systems possible to structure as many type of systems as needed.
This is restricting the structure to a limited amount of types. This makes the modelling options flexible and usable across all
Some types might not be covered. fields.
The reference designation set below is both designating the system and the
system type
=A1.HD1 / %HD1
Reference to the type of “High voltage main supply system”
Unambiguous reference to the technical system
Type aspect %
Use cases Supporting documentation
Utilizing the types aspect, there are significant potential to save time in tagging and design.
Units and technical systems designs may be reused throughout a system model.
RDS-Power Systems allows unambiguously identification of types, by having supporting documentation.
The valves are designated with a reference
designation set.
They are represented both in the functional aspect
=QMA1 =QMA2 =QMA3 =QMA4 and the type aspect
%QMA1 %QMA1 %QMA2 %QMA3
%QMA1 Valve diameter Ø50
%RND1 %RND1 %RND1 %RND1 The sprinklers only get a type designation.
This allows a designer to copy information.
The fan coil systems are all the same type and are
designated with the type aspect. Further information is
=EQA1 =EQA2 =EQA3 found in the supporting documentation.
%EQA1 %EQA1 %EQA1 %EQA1
=QMB1
Fancoil Fancoil Fancoil
system system system =QMA3
=EQA1
=QMA1
M
=QMA2
81346-10
table AA.1
81346-2 table 3
VGB-B 101 ISO 81346-10
Reference designation
system for power plants Structuring principles and
Letter codes for power plant reference designation
systems Power plants RDS 81346 technique
(System key)
VGB-B 102
Reference designation
system for power plants
Letter codes for basic
functions and product
Nuclear power Power transport Power support Storage
classes
Systems Systems Systems Systems
Expires 2021
When numbers are given meaning it is possible to run out All numbers are allowed, it is not possible to run out of numbers
of numbers
No need for preceding numbers (i.e. “00” or “0”)
Number principle 9
2022-07-07 RDS 81346 Technique ApS