1. Connect the power and ground cables to the battery and inverter, ensuring the battery switch is off. Multiple batteries should be connected to a bus bar. 2. Connect the communication cable from the master battery to the inverter's CAN or RS485 port based on the inverter type. For multiple batteries, connect the link ports in a daisy chain configuration. 3. Set the DIP switch on the battery based on the installation manual. For multiple batteries, only set the DIP switch on the master battery.

Uploaded by

Raed Al-Haj
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
122 views

Quick Installation Guide

1. Connect the power and ground cables to the battery and inverter, ensuring the battery switch is off. Multiple batteries should be connected to a bus bar. 2. Connect the communication cable from the master battery to the inverter's CAN or RS485 port based on the inverter type. For multiple batteries, connect the link ports in a daisy chain configuration. 3. Set the DIP switch on the battery based on the installation manual. For multiple batteries, only set the DIP switch on the master battery.

Uploaded by

Raed Al-Haj
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

QUICK INSTALLATION

1.Connect Power Cable & Ground Cable


Warning: Ensure that the battery power switch is off Note: Each battery should be connected to a Bus Bar
when installing multiple batteries.
Single Multiple

Bus Bar

To home ground
To inverter
To inverter

2.Connect Communication Cable


Note: Select CAN or RS485 port based on the communication type Note: Please connect the master battery and the inverter.
of inverter. Single Multiple

+
Link Port 0
or Master Link Port 1

BMS CAN RS485


Link Port 0

Link Port 1

Link Port 0

Link Port 1 Must be vacant


Slave
Inverter Battery
......

Link Port 0

Link Port 1

Note: Please refer to installation manual for custom comm cable making

3.Set the DIP Switch


Single Multiple
Note: Set the DIP switch based + Note: Only the DIP switch
on the inverter you installed. of master battery need to
be set.

4.Start up the System


Note: Make sure the connection to the inverter is correct before starting the battery.
2 Press 1-2 seconds.

Single Multiple + 3 Wait a few seconds


and the batteries will
1 Turn on all
2 Press 1-2 seconds. automatical turn on one
the button. by one, until all the ru-
3 Wait 2-3 seconds and nning lights flash,indi-
1 Turn on.
the running light flash in- cating that the batteries
dicates that the battery are working properly.
is working properly.