FWD EQUP VALVE TechOps
FWD EQUP VALVE TechOps
• MEC
• P50
• Terminal block TB182
• Column 22
• Row A-B-C-D
2
CARD FILE P 50 DETAIL B767
TB 182 pos 22
ATA 21-58
3
PANEL P50, TERMINAL BLOCK TB 182 DETAILS
CHECK FOR MORE THAN ZERO VOLTS DC AT COLUMN 22 IN EACH ROW, ROW A, B, C AND ROW D:
• EACH ROW HAS THREE HOLES, TWO HAVE WIRES GOING INTO THEM AND THE OPEN HOLE
IS A TEST PORT. (SEE NEXT SLIDE FOR DETAILED IMAGE).
• EACH HOLE WILL HAVE THE SAME VOLTAGE WITHIN THE ROW. THE SMALL HOLE WILL TAKE
A SPECIAL PROBE ADAPTER THAT IS HALF SIZE, LIKE FLUKE 8845A-EFPT OR FLUKE TP88.
THESE CAN BE PURCHASED FROM GRAINGER.
ATA 21-58
4
DETAILED IMAGE OF “X” BLOCK IN POSITION 22
• EACH THREE HOLE POSITIONS IN EACH BLOCK HAVE A COMMON BASE AND VOLTAGE CAN
BE CHECKED FROM ANY OF THEM.
ACFT FWD
ATA 21-58
5
P50 GROUNDING POINTS
GOOD LOCATION FOR A GROUND IS ON THE TOP OF THE P50 TOWARD THE LEFT,
OR
THE REGULAR ESD WRIST STRAP ATTACH POINT ON THE RIGHT SIDE OF P50.
ATA 21-58
6
EXAMPLE
SET YOUR METER TO VOLTS DC, GROUND AT TOP OF THE CABINET AND PROBE
WITH SMALLEST ADAPTOR
ATA 21-58
7
FINDINGS
IF YOU FIND MORE THAN ZERO VOLTS YOU HAVE FOUND THE PROBLEM CIRCUIT/VALVE.
have found the only problem.
TO VERIFY THIS IS THE ONLY PROBLEM PROVIDE A GROUND TO THE SAME LOCATION AND HAVE SOMEONE
CHECK TO SEE IF THE FWD EQPT VAL EICAS MESSAGE AND VALVE LIGHT EXTINGUISH.
IF THE MESSAGE IS STILL THERE THEN KEEP TESTING IF THE MESSAGE GOES AWAY YOU
• MORE THAN ZERO VOLTS AT ROW “A” IS A PROBLEM WITH THE OVERBOARD EXHAUST
VALVE, V12 MEL 21-58-07-02-01
• MORE THAN ZERO VOLTS AT ROW “B” IS A PROBLEM WITH THE INBOARD SUPPLY
VALVE, V91 MEL 21-58-08-01-01
• MORE THAN ZERO VOLTS AT ROW “C” IS A PROBLEM WITH THE OVERRIDE VALVE, V140
NO GO ITEM
• MORE THAN ZERO VOLTS AT ROW “D” IS A PROBLEM WITH THE BYPASS SHUTOFF
VALVE, V178 NO GO ITEM, BUT INTERCHANGEABLE WITH V91.
• ONCE VOLTAGE IS FOUND, SHORT THE PORT TO GROUND AND VERIFY THE MESSAGE /
LIGHT GO AWAY.
ATA 21-58
8
HOW TO CHECK V90 MIV & V900 FDARS VALVES IN P36
• WITH POWER OFF, IN THE P36 PANEL REMOVE RELAY K2197. THE SCREWS AND
WASHERS ARE REALLY SMALL.
• CHECK FOR GROUND AT RELAY BASE SOCKET 8, IF YOU HAVE NO GROUND
THERE IS A PROBLEM WITH V900 VALVE / CIRCUITRY. MEL 21-58-15
• CHECK FOR GROUND AT RELAY BASE SOCKET 4, IF YOU HAVE NO GROUND YOU
HAVE A PROBLEM WITH V90 VALVE / CIRCUITRY. NO GO ITEM
ATA 21-58