CAN (GMLAN) Diagnostic Data Link
CAN (GMLAN) Diagnostic Data Link
01 03 0A Low Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 04 0A High Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 82 20 Rich-Lean Response to Lean-Rich Response Ratio 0.000:1 to 255.996:1 ratio 0.0039 / bit
01 83 0A Low Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 84 0A High Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
01 87 10 Sum of O2 Sensor L/R and R/L Half Period Times 0.0000 to 65535 ms 1 ms / bit
05 03 0A Low Sensor Voltage for Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 04 0A High Sensor Voltage For Switch Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 82 20 Rich-Lean Response to Lean-Rich Response Ratio 0.000:1 to 255.996:1 ratio 0.0039 / bit
05 83 0A Low Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 84 0A High Sensor Voltage for Half Period Time Calculation 0.0000 to 7.9900 V 0.122 mv / bit
05 87 10 Sum of O2 Sensor L/R and R/L Half Period Times 0.0000 to 65535 ms 1 ms / bit
Catalyst Monitor
–32768 to +32767
21 A0 90 Catalyst Test Bank 1 1 ms / bit
milliseconds
–32768 to +32767
22 0A 90 Catalyst Test bank 2 1 ms / bit
milliseconds
EGR Bank 1
31 A8 FD EGR Flow Decel Service Test –32.768 to +32.767 kPa 0.001 kPa / bit
31 A9 FD EGR Flow Quick Test –32.768 to +32.767 kPa 0.001 kPa / bit
3A C0 FD EVPD Weak Vacuum Test scaled in kPa –32.768 to +32.767 kPa 0.001 kPa / bit
3A C0 31 EVPD Weak Vacuum Test scaled in liters 0.0 to 65.535 liters 0.001 liters / bit
3A C1 11 EVPD Weak Vacuum Followup Test 0.0 to 6553.5 sec 100 milliseconds / bit
3B C2 B0 EVPD NV 0.040 Test - scaled in percentage slope –100.01 to +100.00% +0.003052 percent / bit
3B C2 32 EVPD NV 0.040 Test - scaled in inches 0.000 to 1.999 inches 0.0000305 inches / bit
3C C2 B0 EVPD NV 0.020 Test - scaled in percentage slope –100.01 to +100.00% +0.003052 percent / bit
3C C3 32 EVPD NV 0.020 Test - scaled in inches 0.000 to 1.999 inches 0.0000305 inches / bit
3D C4 11 EVPD NV Purge Pass Test 0.0 to 6553.5 sec 100 milliseconds / bit
3D C6 11 EVPD Vent Restriction Test 1 0.0 to 6553.5 sec 100 milliseconds / bit
3D C8 31 EVPD Vent Restriction Test2 - scaled in liters 0.0 to 65.535 liters 0.001 liters / bit
41 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
42 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
43 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
45 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
46 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
47 D1 0F Current Feedback Amps Value Test 0.00 to 655.35 amperes 0.01 Ampers / bit
71 E1 FD AIR on - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
71 E2 FD AIR Valve shut - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
71 E3 FD AIR Pump off - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E1 FD AIR on - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E2 FD AIR Valve shut - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E3 FD AIR Pump off - pressure error test –32.768 to +32.767 kPa 0.001 kPa / bit
72 E4 FD AIR on - pressure differential between bank 1 and bank 2 –32.768 to +32.767 kPa 0.001 kPa / bit
A2 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A3 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A4 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A5 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A6 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A7 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A8 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
A9 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
AA 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
AB 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
AC 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit
AD 0C 24 Misfire counts for the last / current driving cycles 0 to 65535 counts 1 count / bit