Multi-DOF Networked Control System
Multi-DOF Networked Control System
ti - DO
D OFF Net
N e tw
work
o r k e d C o n tro l
S y ste
s t em
m In
Instruc
stru c ti
t ions
ons
All rights reserved by Beijing Hollysys Electric Technology Co.,LTD.
When you use our products,if any doubt about the contents of this product
specification,please contact with us.
Beijing Hollysys Electric Technology Co.,LTD (Hollysys Electric Technology for
short)reserves the right without prior notice to modify products and product
specification and other documents of authority.
Hollysys Electric Technology does not assume the use or misuse of the product in
this product specification,caused direct,indirect,special,incidental or
consequential loss or liability.
Hollysys Electric Technology has the products and software patents,copyright and
other intellectual property rights.unauthorized shall not directly or indirectly
copy,manufacture,processing,use of the product and its associated parts.
1 / 11
Multi-DOF networked control system is completely independent development by
Beijing Hollysys Electric Technology Co,LTD, which consists of CAN(or RS485) and
Ethernet network. The system technology is based on the research achievement of the
key technologies of national science and technology major project. HS series of all-digital
networked servo drive has four national patents ( including three invention patents). The
product is stable,reliable and feature rich.
System components
CAN bus
Communication cable
SC-MBOX Introduction
SC-MBOX is a motion controller of bi-directional data transfer from Ethernet to CAN bus which is
designed for application of the HS servo networked control. It is a multifunction controller including
RS232/RS485, 12-way digital outputs, 2-way analog outputs, 8-way digital inputs signal interface, etc. the
CAN bus uses electrical isolation techniques to ensure a reliable and safe bus driver.
2 / 11
SC-MBOX Features
b. Location information, speed information, the load rate information and control state
information for each servo motor feed back to the host computer.
particular condition. Such as initial positioning origin, and a plurality of servo motors can be
NOTE: Please refer to “SC-Mbox Motion Platform System User Manual” for detailed
instructions.
For the SC-MBOX motion controller and HS servo drives communication connections, providing
COM-EXT-3 and COM-EXT-6 which are respectively for 3-axis motion platform and 6-axis motion platform.
The communication adapter plate is installed directly on the 35mm rail, the COM-EXT-3 length is
3 / 11
Triaxial communications adapter palte COM-EXT-3
4 / 11
HS Servo Drive Introduction
HS series networked servo drives are a new generation of cost-effective , practical and reliable
all-digital AC servo motor drives which are launched by Beijing Hollysys Electric Technology CO.,LTD.
HS series networked servo drives use the latest 32 TI with floating point capability of dual-core digital
signal processing chip and a new motor control algorithm, which precisely control the position, velocity,
acceleration and output torque of PMSM. It is used in CNC servo control, textile machinery and other
5 / 11
HS series networked servo drives’ features
a. General motion control functions: position, speed, torque control, mode switch
b. Fast CLA current loop floating point kemel processes, has good performance of dynamic
following.
c. Built-in grid voltage compensation control and automatically adapt to fluctuations of the
grid voltage.
d. Built-in 2-way optional resonance low-pass filter and two resonance notch filter response
i. With overload automatic load shedding algorithm and can be parameterized to choose
whether overload protection and automatic smooth load shedding and restoration.
j. Support RS232 and RS485 communication interface, direct communication with the host
k. Support CAN bus interface and built-in proprietary communication protocol to easy to use
customization.
l. Control port supports logic settings and programmable filter, flexible and reliable.
n. 2-way analog outputs can be observed internal state of drive and be convenient on-site
commissioning.
6 / 11
System features
HS series networked servo drives offer three kinds of bus interfaces: RS232, RS485 and CAN bus.
RS232 interface is standard communication interface. RS485 and CAN bus communication interface is
optional, with electrical isolation and transient voltage suppression protection technology and good
electromagnetic compatibility and reliability. RS232 and RS485 communication protocol is a common used
industrial protocols. CAN bus communication protocol is the method of the company with independent
HS networked servo drives enhance the control function in bus mode, support RS232, RS485 and
Standard RS232 interface achieves the point to point communication of touchscreen or HS servo drive
and PC, and monitors HS servo drive status, parameters read mode and bus mode, which is commonly
used in the parameter configuration and operation monitoring of servo drive. You can choose RS485 bus or
CAN bus to achieve HS servo drives networked operation. Generally, CAN bus is flexibility and reliability
and suitable for networked real-time control, and MODBUS communications can carry large packets to be
suitable for less demanding real-time and large capacity parameter passing and data monitoring.
The figure is the HS networked servo drive using CAN bus and SC-MBOX motion controller constitute
SC-MBOX and host computer achieve Ethernet communication via switch. SC-MBOX and HS servo
achieve CAN bus communication. In addition, SC-MBOX also achieve MODBUS communication via such
as RS232 interfaces with a local computer or a touch screen to facilitate monitoring and debugging.
Meanwhile, SC-MBOX also provide 8 digital inputs, 12 digital outputs and 2 analog output interface, easy to
implement low-cost digital and analog interfaces for data acquisition and control via Ethernet bus.
7 / 11
8 / 11
Multi-node Network Control Application
CAN bus maximum nodes of each SC-MBOX is related with transmission distance and baud rate.
The common application nodes are 3, 6, 9, 16, and so on. SC-MBOX Ethernet interface is connected
through switch. When a switch port is not enough, can be extended by another switch. In the application,
each SC-MBOX has an ID number which is represented by IP address of the Ethernet, for example:
192.168.1.100. The control node of each SC-MBOX is a whole, external cable requires only a 220V power
cord and an Ethernet network line, which greatly simplifies the implementation of on-site wiring project. In
addition, Ethernet communication uses 10M/100M adaptive way that has a high-speed data transfer,
9 / 11
Dimensions(Unit:mm)
SC-MBOX Dimension
10 / 11
Weight L1 L2 L3 L4 L5 L6 L7
Model
(Kg) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
11 / 11
Add: A-10F,HuiZhi Building,No.9 XueQing Road,
HaiDian District Beijing,100085,China
Tel: (86)-10-62932100
Fax: (86)-10-62927946
Http: //www.syn-tron.com