716 Output Module
716 Output Module
Description
The 716 Output Expander Module provides four independently programmable Form C (SPDT) relays and four zone
following annunciator (open collector) outputs for use on the LX-Bus™ of DMP 1912XR and XR200 Command
Processor™ Panels. You can use the 716 module in a variety of remote annunciation and control applications. In
addition to the panel's on-board Form C relays, you can connect multiple 716 modules to the panel for over 200
unique auxiliary relays and annunciator outputs (one for each zone). The 716 module connects only to the LX-Bus
of an interface card. It cannot connect to the keypad data bus.
Addressing the 716
You set the 716 module to an address that is then used by the panel to turn on and off the outputs. For easy
addressing, the 716 contains two on-board rotary switches you can set with a small screwdriver.
Form C Relays
Once addressed, you can assign each of the four Form C relays on the 716 to any one of the panel's Output Options
such as Ready, Phone Trouble, or Communication Fail. These options are programmed with the output number
that matches the 716 module's rotary switch address setting. For example, you can program the panel's Phone
Trouble Output to operate Output # 120 so that a trouble on the panel phone line would toggle relay #1 on a 716
module set to address 120 (Output # 121 would toggle relay # 2 on the same 716).
Duplicating addresses
Any DMP 711, 711E, 714, 715, 5845LX, DS775LX, or 6155LX zone expander modules also used in the system can
be set to the same address as the 716 without conflicting with the module or any of the panel's Output Options.
Although set to the same address, the Form C relays on the 716 operate independently of the zone expander zones.
Tens
}
S
N
E
T
K2
7 8
Relay 2
5 6
9
0 1
BCD
Rotary K3
4
}
3 2
7 8
Switches
Switches Relay 3
5 6
K4 Relay Contacts
0 1
Relay 4
4
3 2
Ones 1 Amp at 24 VDC
S
E
N
O
TXD
7 8
7 8
2
2
outputs, set the 716 address to match the zones you want the outputs
3
3
to address 102. 5 6
4
5 6
4
to follow. If you are only using the Form C relays, set the address to
match the output numbers you want to operate. Note: If you have this type 9
0 1 9
0 1
of switch, align the
8
8
2 3
2 3
To set the address, use a small slotted screwdriver and gently turn the
7
7