02 FusionServer Technical Introduction
02 FusionServer Technical Introduction
1
Content
Part 1: Rack Server - 1288H V6/2288H V6/5288 V6/2488H V6
----------------------- Page 3-30
Part 2: Heterogeneous Server - G5500
----------------------- Page 31-36
Part 3: High-Density Server - X6000 V6
----------------------- Page 37-41
2
Part 1
Page 3
FusionServer V6 Rack Server Panorama
4
FusionServer 1288H V6
• Virtualization
• Cloud computing
• Big data
• Distributed storage
• IT core business
• Carrier-class component • 2 x 3rd Gen Intel® Xeon® • 2 x OCP3.0 NICs, hot- • FDM: The patented Fault Diagnosis &
specifications and 100% derating Scalable Processors, up to 80 swappable Management (FDM) technology
design cores and TDP 270 W per CPU • 6 x PCIe 4.0 expansion slots provides the fault locating accuracy
• Redundancy design: 2 PSU • 32 x DDR4 DIMMs, up to 3200 • 2 x M.2 SSDs, hot-swappable, up to 93%
modules in 1+1 mode, 7 hot- MT/s; Optane™ Persistent hardware RAID • Intelligent Fault Prediction: Drive
swap counter rotary fan modules Memory (PMem), up to 3200 • 7 x fan modules in N+1 mode fault prediction 7 to 30 days before it
in N+1 mode MT/s; total memory capacity up • 2 x PSUs in 1+1 mode occurs
to 12 TB on a single server • DEMT2.0: The patented Dynamic
• Supports up to 10 NVMe SSDs Energy Management Technology
(DEMT) reduces energy consumption
by 18% without compromising
services
• AI Memory Fault Management:
reduces downtime rate by 50%
• Five Major Intelligent Technologies:
improve O&M efficiency by 30%
5
1288H V6 Product Architecture
6
1288H V6 Product Specification
Item Details
7
FusionServer 2288H V6: High Performance and Flexible
Configuration, Adaptive to Various Workloads
• IT core business
• Cloud computing
• Virtualization
• Distributed storage
• Big data analytics
• AI inference
• 12-20 x 3.5'' or 8~31 x 2.5'' • 2 x 3rd Gen Intel® Xeon® • 32 x DIMM and 16 DIMM • FDM: The patented FDM technology
SAS/SATA drives, 4/8/16/24 x Scalable Processors (Ice models alternative, adaptive provides the fault locating accuracy
NVMe SSDs Lake), up to 80 cores and to various workloads up to 93%
• 45 x 2.5'' drives, or 34 x NVMe TDP 270 W per CPU • 2 x OCP 3.0 NICs, hot-swap • Intelligent Fault Prediction: Drive fault
SSDs for ultra-large storage • 4 x 300 W full-height full- • 14 x PCIe 4.0 expansion slots prediction 7 to 30 days before it occurs
• 32 x DDR4 DIMMs, up to 3200 length dual-width GPUs, 8 • 2 x M.2 SSDs, hot-swap, • DEMT2.0: The patented DEMT reduces
MT/s; Optane™ PMem, up to full-height full-length hardware RAID energy consumption by 18% without
3200 MT/s; total memory single-width GPUs, or 11 • 2 x 3000 W PSU modules in compromising services
capacity up to 12 TB on a single half-height half-length 1+1 mode • AI Memory Fault Management:
server GPUs, provide supreme • 4 x hot-swap fan modules in reduces downtime rate by 50%
heterogeneous computing N+1 mode • Five Major Intelligent Technologies:
power improve O&M efficiency by 30%
8
2288H V6-16DIMM Architecture
16 x DDR4 DIMMs,
1 x PCIe 4.0 x16 or 3200 MT/s 2-socket scalable
2 x PCIe 4.0 x8 processors, TDP 270 W
Drive enclosure: 8 x 2.5'' SAS/SATA drives
half-height slots or
Drive: 2 x 2.5“ or 2 x 4* 2.5" SAS/SATA/
3.5“ SAS/SATA drives NVMe drives
1 x PCIe 3.0 x8 and
3 x PCIe 3.0 x16 Drive enclosure: 12 x 3.5" SAS/SATA drives
half-height slots
9
2288H V6-32DIMM Architecture
Drive enclosure: 8 x 2.5'' SAS/SATA drives
Drive enclosure: 4 x 3.5" or 10 x 2.5"
8 x PCIe 4.0 full-height slots SAS/SATA drives
( 6 x PCIe 4.0 x8 slots, 2 x PCIe 4.0 x16 Drive enclosure: 12 x 3.5'' SAS/SATA drives
slots) 32 x DDR4 DIMMs, 2-socket scalable
3200 MT/s processors, TDP 270 W Drive enclosure: 12 x 3.5'' drives (8 x SAS/SATA + 4 x
SAS/SATA/NVMe)
Management
network port, Drive enclosure: 20 x 2.5'' drives (4 x SAS/SATA + 16 x NVMe)
serial port
Flex I/O card 1 Flex I/O card 2
(OCP3.0 NIC) (OCP3.0 NIC) Drive enclosure: 24 x 2.5'' NVMe drives
Rear panel configured with 4 x full-height Drive enclosure: 24 x 2.5" SAS/SATA drives
full-length dual-width GPU cards
Flexible configuration
• Models with 32 DIMMs or 16 DIMMs
• Two OCP 3.0 hot-swappable NICs
• 14 PCIe 4.0 expansion slots for diverse
applications
• Patented design: • Two M.2 SSD cards, supporting hot
hot-swappable
drives swap and hardware RAID
• Two 3000 W PSUs in 1+1 redundancy
11 mode
2288H V6 Logical Topology
12
2288H V6 Product Specification
Item Details
Size 2U
Two 3rd Gen Intel® Xeon® Scalable processors (Ice Lake) (8300/6300/5300/4300 series), with
CPU up to 270 W TDP per processor
Memory Sixteen or thirty-two 3200 MT/s DDR4 memory slots for flexible optional scenarios, hosting up
® TM
to 16 Intel Optane persistent memory 200 series
• Twelve or twenty 3.5" or eight to thirty-one 2.5" SAS/SATA drives
• 4/8/16/24 NVMe SSDs
Local storage • Support up to 45 x 2.5" SAS/SATA drives or 34 NVMe SSDs
• Two M.2 SSDs
RAID RAID 0/1/10/1E/5/50/6/60.
Up to 14 PCIe 4.0 expansion slots, including one PCIe expansion slot for a RAID controller card,
PCIe expansion
two slots for OPC 3.0 Flex IO expansion cards, and 11 PCIe 4.0 expansion slots.
• Four 300 W FHFL dual-width GPU accelerator cards
Heterogenous accelerator • 11 HHHL GPU accelerator cards
card • Eight FHFL single-width GPU accelerator cards
Multiple types of NICs
NIC Two optional hot-swappable OCP 3.0 network adapters in the two Flex IO expansion slots
(determine whether to configure OCP 3.0 network adapters on demand)
PSU Two hot-swappable PSUs (900 W/1200 W/1500 W/2000 W/3000 W) in 1+1 redundancy mode
Fan module Four hot-swappable counter-rotating fan modules in N+1 redundancy mode
Operation temperature 5ºC to 45ºC (41ºF to 113ºF) (confirm to ASHRAE Class A1/A2/A3/A4)
13
Major Composition Modules
1 I/O module 1 2 I/O module 2
3 PSU 4 Chassis
14
Mainboard 20: mini-SAS HD connector C (MINIHD
PORTC/J4)
24: mini-SAS HD connector B (MINIHD
8080 fans use 33, 34, 35, 36, 38, 40, and
Fan module PORTB/J5)
41. Mini
connector 26: mini-SAS HD connector A uses 26 (MINIHD
8038 fans use 34, 36, 40, and 42. SAS/SATA
PORTA/J6)
27: SATA connector 1 (SATA1/J1)
28: SATA connector 2 (SATA2/J2)
PCH pass-through
4
12 x 3.5" SATA drives
or (8 x SATA + 4 x SATA/NVMe) 4 x 2.5" NVMe drives
16
2288H V6 Hardware Configuration Types (2/3)
8 PCH pass-through or
one screw-in RAID
24 x 2.5" drives controller card
(4 x SAS/SATA/NVMe + 20 x NVMe) 4 x 2.5" SAS/SATA drives
17
2288H V6 Hardware Configuration Types (3/3)
•I/O module 1 provides slots 1, 2, and 3. If a two-slot PCIe riser module is used, slot 1 is unavailable. If a
module with 2 x 2.5" drives and one PCIe card is used, slots 1 and 2 are unavailable.
•I/O module 2 provides slots 4, 5, and 6. If a two-slot PCIe riser module is used, slot 4 is unavailable. If a
module with 2 x 2.5" drives and one PCIe card is used, slots 4 and 5 are unavailable.
•I/O module 3 provides slots 7 and 8. If a one-slot PCIe riser module is used, slot 7 is unavailable.
• Provides PCIe slots 1, 2, and 3 when installed in I/O module 1. • Provides PCIe slots 2 and 3 when installed in I/O module 1.
• Provides PCIe slots 4, 5, and 6 when installed in I/O module 2. • Provides PCIe slots 5 and 6 when installed in I/O module 2.
20
IO Expansion — PCIe Riser Card
PCIe Riser Module
21
Main Specification Differences Between Two Models
Specification 32-DIMM Model 16 DIMM Model
W i-Fi/BLUETOOTH+BTN+LED, VGA, two USB 3.0, one Type-
No right mounting ear
C (USB 2.0)+LED, PWRBTN+LED
Mounting ear
UIDBTN+LED, NICLED, fault diagnosis LED, temperature PWRBTN+LED, UIDBTN+LED, NIC LED, fault diagnosis LED,
sensor temperature sensor
1. 8/12/12EXP/25EXP
2. 12 (four NVMe)
3. Four SAS + eight NVMe 1. 8/12/12EXP/25EXP
Front hardware
4. 24 NVMe (four SAS) pass-through 2. 12 (four NVMe)
configuration
5. Up to thirty-seven 2.5“ (front twenty-five 2.5” SATA/SAS
+ rear ten 2.5“ SATA/SAS + rear two 2.5” SATA/SAS)—POC
6. 34 NVMe drives (24 + 1 U 10 NVMe)—POC
CPU ICELAKE CPU with up to 270 W, cloud customized CPU 320 W ICELAKE CPU, with up to energy consumption 270 W
22
Back Window Difference
32 DIMM Model
16 DIMM Model
23
FusionServer 5288 V6: Supports for Warm and Cold Data Storage
and Video Analytics
25
5288 V6 Architecture
Drive enclosure:
24 x 3.5" SAS/SATA drives
management
Flex I/O card 1 network port, Flex I/O card 2
serial port
(OCP3.0 NIC) (OCP3.0 NIC)
26
FusionServer 2488H V6: Mission Critical Server of High
Reliability
• Virtualization
• Cloud computing
• High-performance
computing (HPC)
• Database
• Entry-level in-memory
database (SAP HANA)
• AI inference or training
28
2488H V6 Product Specification
Item Details
Size 2U
Processor Two or four 3rd Gen Intel® Xeon® scalable processors (5300/6300/8300 series), TDP up to 250 W
Memory 48 DDR4 DIMMss, up to 3,200 MT/s; 24 Optane™ PMem 200 series, up to 2,666 MT/s
Supports various drive configurations and hot swappable:
• 8 x 2.5-inch front SAS/SATA drives, 24 x 2.5-inch front SAS/SATA drives, 25 x 2.5-inch front SAS/SATA
Local storage drives, 4 x 2.5-inch front SAS/SATA drives and 8 x NVMe SSDs, 4 x 2.5-inch front SAS/SATA drives and
16 x NVMe SSDs
• Supports flash storage: Dual M.2 SSDs
RAID RAID 0/1/5/50/6/60.
Heterogenous
Supports two dual-slot FHFL GPUs or four single-slot HHHL GPU heterogeneous accelerator cards
accelerator card
(Optional) One OCP 3.0 NIC: supports two GE, two 10GE, two 25GE, or two 100GE ports; supports hot-
NIC swappable, NC-SI, WOL, and PXE
29
Part 2
Page 30
G5500 Data Center Heterogeneous Server Overview
Rich and flexible hardware configurations: 1 chassis, 2 node types, and 3 models
31
G5500 Product Specifications
G5500
Node G560 V5 G530 V5
Application High-density AI inference deployment;
G560 V5 front view Large-scale AI training
Scenario HPC
Full-width heterogeneous
Type Half-width heterogeneous compute node
compute node
GPU module
2 half-width GPU boards
1 full-width GPU board
GPU Each board: 16 T4 or 4 P100/V100 (PCIe)
8 P40/P100/V100 (PCIe)
or 8 V100 (single PCIe slot)
CPU module
1 full-width 2S CPU compute
2 half-width 2S CPU compute modules
module
Server Each node: 2 Xeon® Skylake/Cascade
2 Xeon® Skylake/Cascade CPUs,
G530 V5 front view CPUs, 24 DIMMs
24 DIMMs
G5500
Power 4 hot-swappable 2200 W AC or 240 V HVDC PSUs, with support for the N+N
Supply Units working mode
Fan Modules 6 hot-swappable fan modules, with support for N+1 redundancy
Temperature 5°C to 35°C (41°F to 95°F)
Dimensions
32 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)
(H x W x D)
G5500 Front View — Various Local Storage Resources
1
1
2
2
3
3
2 6 x 2.5-inch NVMe SSDs or SAS/SATA HDDs 2 2 x 2.5-inch NVMe SSDs or SAS/SATA HDDs (OS
installation)
33
G5500 Rear View — Unified Management and Shared
Power and Fan Resources
1 1
2 2
4
3 3
⚫ 2 management modules ⚫ 2 I/O modules ⚫ 4 Platinum PSUs, N+N ⚫ 6 hot-swappable fan modules,
⚫ Each management module ⚫ Each I/O module supports 2 redundancy N+1 redundancy
supports 2 x 10GE optical PCIe x16 slots ⚫ Maximum output power of ⚫ Online maintenance without
ports ⚫ Supports half-height half- each PSU: 2200 W opening the chassis cover
⚫ GE management network length PCIe cards ⚫ Support for AC and 240 V
ports and serial ports HVDC
34
FusionServer G5500 Key Messages
35
Part 3
Page 36
Efficient Heat Dissipation Unleashes the Ultimate Performance
Superior Performance
37
X6000 V6: High-Density Design, Meeting HPC Requirements
PSU
Front view 2+4 balanced configuration, USB port + VGA port Rear view
eliminating I/O bottlenecks between
CPUs and drives
Hardware Specifications
Form 2U chassis, 4 x 1U half-width 2-socket server node
Drive 24 x 2.5" SAS/SATA/SSD/NVMe drives of any configuration
PSU 4 x hot-swappable PSUs in 1+1 or 2+2 redundancy: 68 mm x 138 mm, 1200 W/1500 W/2000 W/3000 W
Power supply 100 V to 240 V AC; 240 V DC
Fan module 4 x hot-swappable fan modules in N+1 redundancy
Operating temperature 5ºC to 35ºC (41°F to 95°F)
Dimensions (H x W x D) 447 mm x 899 mm x 86.1 mm
38
XH321 V6 Node: Industry's Most Powerful Computing Power
Internal view
Superior Computing Flexible
Performance Deployment
16 x DIMM slot 50 mm/68 mm built-in PSU
• 3rd Gen Intel® Xeon® Scalable processors, 40% • InfiniBand HDR 200G high-speed interconnection
higher performance network
• 8-channel DIMMs, 45% higher memory • NVMe SSDs storage
Rear drive bandwidth
backplane
Hardware Specifications
2 x 3rd Gen Intel® Xeon® Scalable processors (6300/8300 series), thermal
RAID 2 x M.2 110 mm VC Processor design power (TDP) up to 270 W, 6.3 TFLOPS/node
controller SSD slot conjoined
card heat sink DIMM slot 16 x DDR4 DIMM slot, up to 3200 MT/s (8-channel)
6 x 2.5" SAS/SATA/SSD/NVMe drives (NVMe SSDs support 2+4 balanced
Rear view Drives configuration.)
PCIe slot 1 PCIe slot 2 PSU RAID controller card RAID 0, 1, 5, 6, 10, 50, or 60; supercapacitor for power failure protection
2 x PCIe 4.0 x16 half-height half-length (HHHL) standard expansion slot, one of
PCIe expansion which can be configured to support multi-host
OCP slot iBMC aggregated Onboard storage Up to two M.2 2280 or 2242 SATA SSDs, in RAID 0, 1, and 5
management
Operating temperature 5ºC to 35ºC (41°F to 95°F)
network port
Dimensions (H x W x D) 218.7 mm x 632 mm x 40.7 mm
39
XH321C V6 Liquid-Cooled Node: 45ºC (113°F) Warm Water
Cooling Brings Down the TCO by 20%
Hardware Specifications
2 x 3rd Gen Intel® Xeon® Scalable processors (6300/8300 series),
Processor
TDP up to 270 W
Liquid cooling of processors and memory
DIMM slot 16 x DDR4 DIMM slot, up to 3200 MT/s (8-channel)
modules + Liquid cooling door
(full liquid cooling solution) 6 x 2.5" SAS/SATA/SSD/NVMe drives (NVMe SSDs support 2+4
Drives
balanced configuration.)
PUE ≤ 1.1
liquid cooling ratio: 80% RAID 0, 1, 5, 6, 10, 50, or 60; supercapacitor for power failure
RAID controller card
+
protection
One PCIe 4.0 x16 HHHL standard expansion slot, multi-host
PCIe expansion
supported
OCP expansion 1 x OCP x16 slot
Onboard storage Up to two M.2 2280 or 2242 SATA SSDs, in RAID 0, 1, and 5
Liquid cooling door
Operating temperature 5ºC to 35ºC (41°F to 95°F)
40 Dimensions (H x W x D) 218.7 mm x 632 mm x 40.7 mm
Thank you.