Brocade Fabric OS 8.2.2d Release Notes
Version 2.0
Broadcom FOS-822d-RN100
April 20, 2021
Fabric OS 8.2.2d Brocade Fabric OS 8.2.2d Release Notes
Copyright © 2021 Broadcom. All Rights Reserved. Broadcom, the pulse logo, Brocade, and the stylized B logo are among
the trademarks of Broadcom in the United States, the EU, and/or other countries. The term “Broadcom” refers to
Broadcom Inc. and/or its subsidiaries.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve
reliability, function, or design. Information furnished by Broadcom is believed to be accurate and reliable. However,
Broadcom does not assume any liability arising out of the application or use of this information, nor the application or
use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of
others.
The product described by this document may contain open source software covered by the GNU General Public License
or other open source license agreements. To find out which open source software is included in Brocade products, to
view the licensing terms applicable to the open source software, and to obtain a copy of the programming source code,
please download the open source disclosure documents in the Broadcom Customer Support Portal (CSP). If you do not
have a CSP account or are unable to log in, please contact your support provider for this information.
Use of all versions of Brocade’s Fabric OS is subject to the terms and conditions of the Brocade Fabric Operating System
and Feature Licenses and License Keys End User License Agreement, effective October 1, 2019, as amended by Brocade
from time to time. It is the user’s responsibility to understand and comply with the terms of the EULA. By downloading,
installing, using, posting, distributing or otherwise making available FOS, you agree to be bound on an ongoing basis by
the EULA as updated by Brocade from time to time.
Broadcom FOS-822d-RN100
2
Fabric OS 8.2.2d Brocade Fabric OS 8.2.2d Release Notes
Table of Contents
Broadcom FOS-822d-RN100
3
Fabric OS 8.2.2d Brocade Fabric OS 8.2.2d Release Notes
Broadcom FOS-822d-RN100
4
Fabric OS 8.2.2d Brocade Fabric OS 8.2.2d Release Notes
Broadcom FOS-822d-RN100
5
Chapter 1: Preface
For product support information and the latest information on contacting the Technical Assistance Center, go to
https://www.broadcom.com/support/fibre-channel-networking/. If you purchased Brocade product support directly
from Broadcom, use one of the following methods to contact the Technical Assistance Center 24x7.
Online Telephone
For nonurgent issues, the preferred method is to log in to Required for Severity 1 (critical) issues:
myBroadcom at https://www.broadcom.com/mybroadcom. (You Please call Fibre Channel Networking Global Support at one of
must initially register to gain access to the Customer Support the numbers listed at https://www.broadcom.com/support/fibre-
Portal.) Once there, select Customer Support Portal > Support channel-networking/.
Portal. You will now be able to navigate to the following sites:
Knowledge Search: Clicking the top-right magnifying glass
brings up a search bar.
Case Management: The legacy MyBrocade case
management tool (MyCases) has been replaced with the Fibre
Channel Networking case management tool.
DocSafe: You can download software and documentation.
Other Resources: Licensing Portal (top), SAN Health (top and
bottom), Communities (top), Education (top).
If you purchased Brocade product support from a Broadcom OEM/solution provider, contact your OEM/solution
provider for all your product support needs.
• OEM/solution providers are trained and certified by Broadcom to support Brocade products.
• Broadcom provides backline support for issues that cannot be resolved by the OEM/solution provider.
• Brocade Supplemental Support augments your existing OEM support contract, providing direct access to Brocade
expertise. For more information on this option, contact Broadcom or your OEM.
For questions regarding service levels and response times, contact your OEM/solution provider.
To expedite your call, have the following information immediately available:
1. General Information:
Technical support contract number, if applicable.
Switch model.
Switch operating system version.
Error numbers and messages received.
supportSave command output and associated files.
For dual-CP platforms running Fabric OS 6.2 and above, the supportSave command gathers information from
both CPs and any AP blades installed in the chassis.
Detailed description of the problem, including the switch or fabric behavior immediately following the problem and
any specific questions.
Description of any troubleshooting steps already performed and the results.
Broadcom FOS-822d-RN100
6
Serial console and Telnet session logs.
Syslog message logs.
2. Switch Serial Number.
The switch serial number is provided on the serial number label, examples of which follow:
FT00X0054E9
White papers, data sheets are available at www.broadcom.com. Product documentation for all supported releases is
available at myBroadcom to registered users. Registered users can also find release notes at myBroadcom.
Broadcom FOS-822d-RN100
7
Chapter 2: Locating Product Manuals and Release Notes
The following sections outline how to locate and download Brocade product manuals and release notes from
myBroadcom. Although the illustrations show Fibre Channel and Fabric OS (FOS), they work for all Brocade products and
operating systems.
Broadcom FOS-822d-RN100
8
2.1.2 Locating Product Manuals and Release Notes on myBroadcom
Complete the following steps to locate your product manuals on myBroadcom.
1. Go to https://www.broadcom.com/mybroadcom/, click Login, and enter your username and password.
If you do not have an account, click Register to set up your account.
2. Select Customer Support Portal > DocSafe (Software/Document Downloads).
3. Choose one of the following:
• Enter the product name or the software version number in the Search box. For example, the following
search is for software and documentation files for software version 8.2.
• Click the Product Search box, select FIBRE CHANNEL NETWORKING, and select a product from the
product list.
The list of documents and software available for the product displays.
4. Clear the Software check box to list only the documents and release notes.
Broadcom FOS-822d-RN100
9
2.2 Document Feedback
Quality is our first concern and we have made every effort to ensure the accuracy and completeness of this document. If
you find an error or omission or you think that a topic needs further development, we want to hear from you. You can
provide feedback by sending an email to [email protected]. Provide the publication title,
publication number, and as much detail as possible, including the topic heading and page number, as well as your
suggestions for improvement.
Broadcom FOS-822d-RN100
10
Chapter 3: Overview
Fabric OS 8.2.2d is a patch release based on Fabric OS 8.2.2c. All hardware platforms and features supported in
FOS 8.2.2c are also supported in FOS 8.2.2d. This release contains feature enhancements and fixes for defects listed at
the end of this document.
Broadcom FOS-822d-RN100
11
Chapter 4: What’s New in FOS 8.2.2d
Broadcom FOS-822d-RN100
12
Chapter 5: What’s New in FOS 8.2.2
The following sections list new, modified, and deprecated software features for this release.
Broadcom FOS-822d-RN100
13
Chapter 6: What’s New in FOS 8.2.1
6.1 Hardware
The following sections list new hardware introduced with this release and hardware that is no longer supported with this
release.
The following sections list new, modified, and deprecated software features for this release.
Broadcom FOS-822d-RN100
14
6.2.1.1 Counterfeit License Protection
FOS 8.2.1 introduces counterfeit license protection (CLP) on the Brocade 6505, 6510, G610, G620, and 7810 to prevent
misuse of the licenseAdd command. CLP performs the following actions based on the number of times that the
licenseAdd command is invoked:
RASLOG WARNING message when 25 invalid licenseAdd operations are detected within a 24-hour period.
RASLOG CRITICAL message when 40 invalid licenseAdd operations are detected within a 24-hour period.
Shuts down a switch when 50 invalid licenseAdd operations are detected within a 24-hour period.
A switch that is shut down due to CLP detection will no longer be able to boot to a functional state. Customers may
request a replacement unit from their support provider.
FOS 8.2.1 expands REST API support from that supported in FOS 8.2.0a with the following new features and
corresponding RESTCONF modules:
Physical chassis, FRU, and optical transceiver: brocade-chassis, brocade-fru, and brocade-media
Switch configuration: brocade-fibrechannel-configuration
SupportSave: brocade-operation-supportsave and brocade-operation-showstatus
Trunking: brocade-fibrechannel-trunk
RASLOG and syslog configuration: brocade-logging
System security: brocade-security
System time zone and time server: brocade-time
Monitoring and Alerting Policy Suite (MAPS): brocade-maps
FOS 8.2.1 enhances the following existing RESTCONF modules:
brocade-fibrechannel
brocade-fibrechannel-switch
brocade-access-gateway
For a detailed description of the new modules and attributes, refer to the Brocade Fabric OS REST API Reference Manual
for FOS 8.2.1.
FOS 8.2.1 implements hardware-based ingress rate limiting on the management interface of X6 directors to prevent
denial of service (DOS) attacks through the Ethernet management interface. When this feature is enabled, hardware
performs ingress rate limiting when a DOS attack on the Eth0 or Eth3 management interface is detected. Normal
management application traffic from Web Tools, SNMP, and Brocade Network Advisor is not affected when there is no
DOS attack. These applications may appear sluggish when a DOS attack is detected.
FOS 8.2.1 adds MAPS monitoring of Cisco UCS Fabric Interconnect (FI) connections to Brocade switches in NPV mode.
MAPS monitors the distribution of UCS servers over the uplinks between FI and Brocade switches to remain balanced
over time. When MAPS detects an imbalance, it alerts the SAN administrator of the condition or triggers an automatic
rebalance action.
6.2.2.1.2 Miscellaneous
FOS 8.2.1 replaces the default rule names in FOS 8.2.0x detailed in the following table with the new default rule names:
FOS 8.2.0x Rule Names FOS 8.2.1 Rule Names
defALL_DPIP_EXTN_FLOW_C defALL_DPIP_EXTN_FLOW_P_90
defALL_DPIP_EXTN_FLOW_M defALL_DPIP_EXTN_FLOW_P_80
defALL_DPIP_EXTN_FLOW_A defALL_DPIP_EXTN_FLOW_P_65
defALL_DPIP_EXTN_FLOW_MAX defALL_DPIP_EXTN_FLOW_P_TOTAL
NOTE The default rules will be automatically converted to the new rule names during firmware upgrade from
FOS 8.2.0x to FOS 8.2.1 or later. However, user-defined rules of the IP_EXTN_FLOW monitoring
system must be changed manually to follow the new rule name format.
FOS 8.2.1 changes the alert severity from ERROR to CRITICAL for the following default rule:
defALL_E_PORTSC3TXTO_20 ALL_E_PORTS(C3TXTO/MIN>20) RASLOG
FOS 8.2.1 changes the alert severity from WARNING to ERROR for the following default rule:
defALL_FANFAN_STATE_FAULTY ALL_FANS(FAN_STATE/NONE==FAULTY) RASLOG
FOS 7.4 and later support Slow-Drain Device Quarantine (SDDQ) to mitigate congestion due to slow-drain devices
connected to switches in native mode. FOS 8.2.1 enhances SDDQ support on AG to be able to quarantine slow-drain
devices connected to Access Gateway.
FOS 8.2.1 adds support of the portCfgNpivPort command for a switch in AG mode. With this support,
administrators can enable or disable NPIV mode for a port when a switch is in Access Gateway mode.
Broadcom FOS-822d-RN100
16
6.2.2.3 Fabric Services Enhancements
FOS 8.2.1 adds support of the Get Zone Set (GZS) and Get Active Zone Set (GAZS) commands under FC-GS-8 for zone
servers. GZS queries for Zone Set Database, whereas GAZS queries for Active Zone Set (or Effective Configuration Set).
FOS 8.2.1 enhances the impaired port feature introduced in FOS 8.2.0. With FOS 8.2.0, an impaired port can be used as a
principal link, which is used in fabric-related events, even though there are parallel nonimpaired links available. With
FOS 8.2.1, when a principal link is impaired and parallel links exist, an alternate link will be selected as the principal link.
FOS 8.2.1 adds the new -minDiff to passwdcfg CLI command to enable SAN administrators to configure the
password policy to require the minimum number of characters that must be different between a current password and a
new password.
FOS 8.2.1 displays a logout message for SSH or Telnet session logout, exit, or timeout on the standard session terminal
window.
FOS 8.2.1 adds the -force option to the rootAccess command to bypass the interactive prompt of the command
execution.
FOS 8.2.1 adds support of HTTP server connection KeepAlive. The server KeepAlive is supported only with secure HTTPS
connections to switches. The KeepAlive support may be enabled with the command mgmtapp --enable
keepalive in FOS 8.2.1 or later.
FOS 8.2.1 introduces options to the configure CLI command to allow a number of switch configuration parameters to
be set without going through the interactive CLI menu. For details, refer to the Brocade Fabric OS Command Reference
Manual for FOS 8.2.1.
FOS 8.2.1 supports dynamic LAG (LACP) on Gigabit Ethernet LAN ports on extension platforms.
Broadcom FOS-822d-RN100
17
6.2.2.7 Power Supply Microcontroller Firmware Utility
Some power supply models for Brocade Gen 6 platforms support field upgrade of the firmware image used by their
microcontrollers. FOS 8.2.1 introduces the psutil CLI command for field upgrade of the power supply microcontroller
firmware. The power supply firmware is packaged as part of FOS 8.2.1 and later. Administrators can use the psutil
command to check the power supply firmware version and when necessary upgrade to a later version.
FOS 8.2.1 enhances the chassisName command to increase the name length from 15 characters to 31 characters on
the DCX 8510 and X6 directors.
FOS 8.2.1 supports the portcfgislmode command to configure ISL R_RDY mode on the ISLs in a base switch, that is,
the XISLs. With this enhancement, devices that support R_RDY mode can also be used on XISLs.
FOS 8.2.1 displays the alert thresholds for peer port optics through the sfpShow -link option. The alert thresholds
are displayed for voltage, temperature, Tx Bias, Tx Power, and Rx Power metrics. The alert thresholds are displayed for
peer port optics only.
The following sections list new, modified, and deprecated commands for this release.
Broadcom FOS-822d-RN100
18
6.3.3 Deprecated Commands
The Brocade Fabric OS Command Reference Manual documents all FOS commands that are officially supported. Any
commands not listed in the command reference for a specific release are not supported and may be subject to removal
without notification. Refer to the Deprecated Commands section in the Brocade Fabric OS Command Reference Manual
for Fabric OS 8.2.1.
This software conforms to the Fibre Channel standards in a manner consistent with accepted engineering practices and
procedures. In certain cases, Brocade might add proprietary supplemental functions to those specified in the standards.
For a list of FC standards conformance, visit the following Broadcom SAN Standards website:
https://www.broadcom.com/support/fibre-channel-networking/san-standards/
Broadcom FOS-822d-RN100
19
Chapter 7: Software License Support
Fabric OS 8.2 includes all basic switch and fabric support software, as well as optionally licensed software that is enabled
using license keys.
Optionally licensed features include:
Brocade Ports on Demand – This license allows customers to instantly scale the fabric by provisioning additional SFP
ports via license key upgrade. (Applies to select switch models.)
Brocade Q-Flex Ports on Demand – This license allows customers to further scale the fabric and increase flexibility by
provisioning additional 4x32G QSFP ports via license key upgrade. (Applies to the Brocade G620 only.)
Brocade Extended Fabrics – This license provides greater than 10 km of switched fabric connectivity at full bandwidth
over long distances (depending on the platform, this can be up to 3000 km).
Brocade ISL Trunking – This license provides the ability to aggregate multiple physical links into one logical link for
enhanced network performance and fault tolerance. It also includes Access Gateway ISL Trunking on those products that
support Access Gateway deployment.
Brocade Fabric Vision – This license enables support for MAPS (Monitoring and Alerting Policy Suite), Flow Vision, and
ClearLink (D_Port) when connecting to non-Brocade devices. MAPS enables rules-based monitoring and alerting
capabilities, and it provides comprehensive dashboards to quickly troubleshoot problems in Brocade SAN environments.
Flow Vision enables host-to-LUN flow monitoring, application flow mirroring for nondisruptive capture and deeper
analysis, and a test traffic flow generation function for SAN infrastructure validation. Support for D_Port to non-Brocade
devices allows extensive diagnostic testing of links to devices other than Brocade switches and adapters.
NOTE On Brocade G620, G630, Brocade X6-8, and Brocade X6-4 platforms, this license enables the use of
IO Insight capability. The license itself is identified as “Fabric Vision and IO Insight” on these
platforms.
FICON Management Server – Also known as CUP (Control Unit Port), this license enables host control of switches in
mainframe environments.
Integrated Routing – This license allows any Fibre Channel port in a DCX 8510-8, DCX 8510-4, Brocade 6510,
Brocade 6520, Brocade 7840, or Brocade G620 to be configured as an EX_Port supporting Fibre Channel Routing (FCR).
This eliminates the need to add an FR4-18i blade or use a Brocade 7500 for FCR purposes, and it also provides either
quadruple or octuple the bandwidth for each FCR connection (when connected to another 16Gb/s- or 32Gb/s-capable
port).
Integrated Routing Ports on Demand – This license allows any Fibre Channel port in a Brocade 7810, G630, X6-8, or X6-4
to be configured as an EX_Port supporting Fibre Channel Routing. The maximum number of EX_Ports supported per
platform is provided in the license. This eliminates the need to add an FR4-18i blade or use a Brocade 7500 for FCR
purposes, and it also provides octuple the bandwidth for each FCR connection (when connected to another 32Gb/s-
capable port).
Broadcom FOS-822d-RN100
20
Advanced Extension – This license enables two advanced extension features: FCIP Trunking and Adaptive Rate Limiting.
The FCIP Trunking feature allows multiple IP source and destination address pairs (defined as FCIP circuits) via multiple
1GbE or 10GbE interfaces to provide a high-bandwidth FCIP tunnel and failover resiliency. In addition, each FCIP circuit
supports four QoS classes (Class-F, High, Medium, and Low Priority), each as a TCP connection. The Adaptive Rate
Limiting feature provides a minimum bandwidth guarantee for each tunnel with full utilization of the available network
bandwidth without impacting throughput performance under a high-traffic load. This license is available on the
DCX 8510-8/DCX 8510-4 for the FX8-24 on an individual slot basis. The upgrade license on Brocade 7810 includes this
license to enable 10GbE ports.
10GbE FCIP/10G Fibre Channel – This license enables the two 10GbE ports on the FX8-24 and/or the 10G FC capability
on FC16-xx blade ports supported on DCX 8510 platforms except for the FC16-64 blade. On the Brocade 6510 and
Brocade 6520, this license enables 10G FC ports. The upgrade license on Brocade 7810 includes this license to enable six
10GbE ports. This license is not applicable to the Brocade 7840, Brocade G620, or Brocade X6 platforms.
On the FX8-24:
With this license installed and assigned to a slot with an FX8-24 blade, two additional operating modes (in addition
to 10x1GbE ports mode) can be selected:
10x1GbE ports and 1x10GbE ports
or
2x10GbE ports
On the FC16-xx:
Enables 10G FC capability on an FC16-xx blade in a slot that has this license.
On the Brocade 6510 and Brocade 6520:
Enables 10G FC capability on Brocade 6510 and Brocade 6520 switches.
This license is available on the DCX 8510-8 and DCX 8510-4 on an individual slot basis.
Advanced FICON Acceleration – This licensed feature uses specialized data management techniques and automated
intelligence to accelerate FICON tape read and write and IBM Global Mirror data replication operations over distance,
while maintaining the integrity of command and acknowledgement sequences. This license is available on the
Brocade 7840 and the Brocade DCX 8510-8 and DCX 8510-4 for the FX8-24 on an individual slot basis.
ICL POD License – This license activates ICL ports on DCX 8510 or X6 platform core blades. An ICL license must be
installed on the director platforms at both ends of the ICL connection.
On the Brocade DCX 8510-8 and X6-8:
The first ICL POD license enables 16 (half of the total) UltraScale ICL QSFP ports on the DCX 8510-8 or X6-8 Directors,
enabling 8 ICL ports on each core blade. These are QSFP port numbers 0, 1, 2, 3, 4, 5, 6, and 7 on the DCX 8510-8;
while on the X6-8, the QSFP port numbers are 0, 1, 2, 3, 8, 9, 10, and 11. The second ICL POD license enables the
remaining 16 UltraScale ICL QSFP ports on the directors. These are QSFP port numbers 8, 9, 10, 11, 12, 13, 14, and
15 on each core blade of the DCX 8510-8; while on the X6-8, these are QSFP port numbers 4, 5, 6, 7, 12, 13, 14, and
15 on each core blade.
Note that the trunk boundaries are different between CR32-8 core blades on the X6-8 and CR16-8 core blades on
the DCX 8510-8.
Broadcom FOS-822d-RN100
21
On the Brocade DCX 8510-4 and X6-4:
ICL POD licenses are different between X6-4 and DCX 8510-4 Directors. On the X6-4, the first ICL POD license enables
8 (half of the total) UltraScale ICL QSFP ports on the director, enabling 4 ICL ports on each core blade, which are
QSFP port numbers 0, 1, 4, and 5. The second ICL POD license on the X6-4 enables the remaining 8 UltraScale ICL
QSFP ports on the director, which are QSFP port numbers 2, 3, 6, and 7 on each core blade. On the
DCX 8510-4, a single ICL POD license enables all 16 UltraScale ICL QSFP ports on the director.
Enterprise ICL (EICL) License – The EICL license is required on a Brocade DCX 8510 chassis when that chassis is connected
to four or more Brocade DCX 8510 chassis via ICLs. This license is not applicable to X6 Directors.
This license requirement does not depend upon the total number of DCX 8510 chassis that exist in a fabric, but only on
the number of other chassis connected to a DCX 8510 via ICLs.
NOTE The EICL license supports a maximum of nine (9) DCX 8510 chassis connected in a full-mesh
topology or up to twelve (12) DCX 8510 chassis connected in a core-edge topology. Refer to the
Brocade SAN Scalability Guidelines document for additional information.
WAN Rate Upgrade 1 License – The WAN Rate Upgrade 1 license provides additional WAN throughput up to 10Gb/s on
a Brocade 7840. The base configuration for a Brocade 7840 without this license provides WAN throughput up to 5Gb/s.
WAN Rate Upgrade 2 License – The WAN Rate Upgrade 2 license provides unlimited WAN throughput (up to the
hardware limit) on a Brocade 7840. WAN Rate Upgrade 2 licenses also enable the use of two 40GbE ports on a
Brocade 7840. The 40GbE ports cannot be configured without the WAN Rate Upgrade 2 license. A WAN Rate Upgrade 1
license must be installed on a Brocade 7840 before a WAN Rate Upgrade 2 license is installed. A WAN Rate Upgrade 1
license cannot be removed before the WAN Rate Upgrade 2 license has been removed.
NOTE The WAN Rate Upgrade 1 and WAN Rate Upgrade 2 licenses apply only to Brocade 7840 platforms.
They control the aggregate bandwidth for all tunnels on that Brocade 7840. The entire capacity
controlled by the licenses can be assigned to a single tunnel, or a portion of the capacity can be
assigned to multiple tunnels. The total bandwidth aggregated for all tunnels should not exceed the
limits established by the licenses.
Extension Upgrade License – The Extension Upgrade license is available on the Brocade 7810, enabling
additional ports, capacity, and features that provide the following: 12 32Gb/s FC ports, 6 10Gb/s Ethernet ports,
4 tunnels, 6 circuits per tunnel, 2.5Gb/s WAN throughput, Fabric Vision, Extension Trunking, Brocade ISL
Trunking, Integrated Routing Ports on Demand, and Brocade Extended Fabrics. This license is shown as a
combination of existing FOS licenses that enable the above capabilities and features.
NOTE FOS v8.2.2 and later supports 6 10Gb/s Ethernet ports in base configuration of Brocade 7810. 10
Gb/s Ethernet ports can be enabled without the Extension Upgrade license.
Broadcom FOS-822d-RN100
22
7.2 Temporary License Support
The following licenses are available in Fabric OS 8.2.2 as either universal temporary or regular temporary licenses:
Fabric (E_Port)
Extended Fabric
Trunking
High Performance Extension
Advanced Performance Monitoring
Fabric Watch
Integrated Routing
Integrated Routing Ports on Demand
Advanced Extension
Advanced FICON Acceleration
10GbE FCIP/10GFibre Channel
FICON Management Server (CUP)
Enterprise ICL
Fabric Vision
WAN Rate Upgrade 1
WAN Rate Upgrade 2
Extension Upgrade
NOTE Temporary licenses for features available on a per-slot basis enable the feature for any and all slots
in the chassis.
Temporary and universal temporary licenses have durations and expiration dates established in the licenses themselves.
FOS will accept up to two temporary licenses and a single universal license on a unit. Universal temporary license keys
can be installed only once on a particular switch, but they can be applied to as many switches as desired. Temporary use
duration (the length of time for which the feature will be enabled on a switch) is provided with the license key. All
universal temporary license keys have an expiration date after which the license can no longer be installed on any unit.
Temporary and universal temporary licenses for Brocade 7810 Extension Upgrade are supported with FOS v8.2.2 or
later. Temporary and universal temporary license for Extension Upgrade do not enable additional ports on 7810.
Broadcom FOS-822d-RN100
23
Chapter 8: Hardware Support
Use of this Fabric OS release on a switch that has reached its end of support date will result in restricted use of some
support level functions. Firmwaredownload, SupportSave and other support commands will not be available. All other
basic operational capabilities will be unaffected.
1 8510 core blade QSFPs, part numbers 57-1000267-01 and 57-0000090-01, are not supported in the FC16-64. The QSFPs supported in the FC16-64, part number
Broadcom FOS-822d-RN100
24
8.2.2 X6-8/X6-4 Blade Support
Fabric OS 8.2 software is fully qualified and supports the blades for the X6-8 and X6-4 as noted in the following table.
None of the legacy blades (16G or lower speed) are supported in the Gen 6 chassis.
Blades OS Support
FC32-48 32G FC blade Supported.
SX6 Gen 6 Extension blade Supported.
Up to a maximum of four blades of this type.
FC32-64 32G FC/FCoE blade Supported.
A maximum of two blades of this type is supported when four SX6 blades are
present in the same X6-8 chassis.
NOTE The QSFP supported in the FC16-64, part number 57-1000294-02, is also supported on X6 core
blades under the condition that the port speed must be configured at a fixed 16Gb/s. Otherwise, the
optics will fault.
Broadcom FOS-822d-RN100
25
8.3.3 DCX 8510-8 Power Supply Requirements
8.3.3.1 Typical Power Supply Requirements for Blades in DCX 8510-8 Backbones
(For a specific calculation of power draw with different blade combinations, see Appendix A, Power Specifications, in the
Brocade DCX 8510-8 Backbone Hardware Reference Manual.)
Configured Blades Type of DCX 8510-8 DCX 8510-8 Comments
Number of Blade @110 VAC @200–240 VAC
Ports (Redundant (Redundant
Configurations) Configurations)
Any FC16-32, Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
combination of FC16-64 Supplies Supplies
8-Gb or 16-Gb 110 VAC: 2+2 3 Power Supplies
ports with
QSFP ICLs
256 16-Gb FC16-32, Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports + QSFP FC16-48 Supplies Supplies
ICLs (Maximum of 110 VAC: 2+23 Power Supplies
fully populated
FC16-32 Max 8 FC16-32 port blades
blades),
FC16-64
192 16-Gb FC16-32, Port / 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports & max 2 FC16-48, Intelligent Supplies Supplies
intelligent FC16-64, Blade 110 VAC: 2+23 Power Supplies
blades (FX8-24) FX8-24
with QSFP ICLs Max four FC16-48 port blades
and max 2 intelligent blades
336 16-Gb FC16-48 Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports + QSFP (Maximum of Supplies Supplies
ICLs seven FC16-48 110 VAC: 2+23 Power Supplies
blades, with Max 7 FC16-48 port blades
one empty port
blade slot)
384 16-Gb FC16-48 Port Blade Not Supported 4 Power Supplies 200–240 VAC:
ports + QSFP For DCX 8510-8, four (2+2)3
ICLs 220 VAC Power Supplies are
required.
384 16-Gb FC16-64 Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports + QSFP Supplies Supplies
ICLs 110 VAC: 2+21 Power Supplies
Any FC16-32, Intelligent Dependent on 2 or 4 Power For DCX 8510-8, four (2+2)3
combination of FC16-48, Blade / the configuration. Supplies, 220 VAC Power Supplies are
8-Gb or 16-Gb FX8-24 Combination Requires a depending on the required when any special-
ports and power configuration purpose blades are installed.
intelligent calculation for
blades with the specific
QSFP ICLs configuration.
3 Whena 2+2 power supply combination is used, the users are advised to configure the MAPS setting for switch Marginal State to be one Bad Power Supply.
Broadcom FOS-822d-RN100
26
Configured Blades Type of DCX 8510-8 DCX 8510-8 Comments
Number of Blade @110 VAC @200–240 VAC
Ports (Redundant (Redundant
Configurations) Configurations)
512 16-Gb FC16-64 Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports Supplies Supplies
110 VAC: 2+23 Power Supplies
512 16-Gb FC16-64 Port Blade 4 Power 2 Power Supplies 200–240 VAC: 1+1 Power
ports + QSFP Supplies Supplies
ICLs 110 VAC: 2+23 Power Supplies
8.3.4.1 Typical Power Supply Requirements for Blades in DCX 8510-4 Backbones
(For a specific calculation of power draw with different blade combinations, refer to Appendix A, Power Specifications, in
the Brocade DCX 8510-4 Backbone Hardware Reference Manual.)
Configured Blades Type of Blade DCX 8510-4 DCX 8510-4 Comments
Number of @110 VAC @200–240 VAC
Ports (Redundant (Redundant
Configurations) Configurations)
96 ports max FC16-32 Port Blade 2 Power Supplies 2 Power Supplies 1+1 redundancy
with QSFP ICLs with 110 or
200–240 VAC
power supplies
Any combination FC16-32, Intelligent Blade / Not Supported 2 Power Supplies 200–240 VAC:
of 8-Gb or 16-Gb FC16-48, Combination 1+1 Power
ports and FC16-64, Supplies
intelligent blades FX8-24
with QSFP ICLs
Broadcom FOS-822d-RN100
27
8.3.6 X6-8 Power Supply Requirements
(For a specific calculation of power draw with different blade combinations, refer to the Power Consumption section in
the Brocade X6-8 Director Hardware Installation Guide.)
Configured Blades Type of X6-8 X6-8
Number of Blade @100–120 VAC @200–240 VAC
Ports (Redundant Configurations) 4 (Redundant Configurations)4,5
(For a specific calculation of power draw with different blade combinations, refer to the Power Consumption section in
the Brocade X6-4 Director Hardware Installation Guide.)
Configured Blades Type of Blade X6-4 X6-4
Number of Ports @100–120 VAC @200–240 VAC
(Redundant (Redundant Configurations)5
Configurations) 5
Any combination of FC32-48, Port Blade Not Supported 2 Power Supplies
32Gb/s ports and FC32-64, Extension Blade (1+1 redundancy)
Extension blades SX6
with QSFP ICLs
4 For N+1 or N+N redundancy, N PSUs must be available for the system to support the load. In other words, failure of up to 1 PSU in an N+1 configuration or N PSUs in an N+N configuration
Broadcom FOS-822d-RN100
28
8.3.8 Supported Optics
For a list of supported fiber-optic transceivers that are available from Brocade, refer to the latest version of the Brocade
Transceiver Support Matrix available online at www.broadcom.com.
Note: In FOS 8.2.1 and later, the port speed configuration and SFP speed must match for WAN interfaces to come online
on Extension platforms. See Extension for details.
Broadcom FOS-822d-RN100
29
Chapter 9: Software Upgrades and Downgrades
This section contains important details to consider before migrating to or from this FOS release.
Any firmware activation on a DCX 8510-8 or DCX 8510-4 with an FX8-24 blade installed will disrupt I/O traffic on the FCIP
links.
Disruptive upgrades to Fabric OS 8.2.2d are allowed and are supported from FOS 8.0.x (up to a two-level migration)
using the optional -s parameter with the firmwaredownload command.
Firmware downgrades from FOS 8.2.2d to FOS 8.2.0x or earlier versions on the Brocade G610 or 6505 are not allowed.
On a Brocade G620 with the switchShow command displaying “switchType” field identified as 162.5, the minimum
required FOS version is v8.2.1a. Firmware downgrades to FOS 8.2.1 or earlier versions are not allowed.
On a Brocade G620 with the switchShow command displaying “switchType” field identified as 162.7, or on a Brocade
G630 with switchShow command displaying “switchType” field identified as 173.4, the minimum required FOS version
is v8.2.2c. Firmware downgrade to earlier versions are not allowed.
Broadcom FOS-822d-RN100
30
On any Brocade SAN switch platform running FOS v8.2.2a or later, firmware upgrade or downgrade must acknowledge
and accept the EULA before firmware can be installed. Firmware migration from FOS v8.2.1c and earlier or from
FOS v8.2.2 to this FOS version does not require EULA acceptance.
On Brocade 7810 or SX6 blade, if any of the following optics part numbers if used, firmware downgrade to versions
earlier than FOS v8.2.2c or to versions earlier than FOS v8.2.1e are blocked to avoid ports using these part numbers be
disabled after downgrade:
32Gb/s Fibre Channel SWL SFP (part number 57-1000485-01)
32Gb/s Fibre Channel LWL SFP (part number 57-1000486-01)
16Gb/s Fibre Channel SWL SFP (part number 57-1000487-01)
16Gb/s Fibre Channel LWL SFP (part number 57-1000488-01)
16Gb/s Fibre Channel ELWL SFP (part number 57-1000489-01)
10Gb/s Fibre Channel SWL SFP (part number 57-1000492-01)
10Gb/s Fibre Channel LWL SFP (part number 57-1000493-01)
32Gb/s Fibre Channel ELWL (part number 57-1000494-01)
Broadcom FOS-822d-RN100
31
Chapter 10: Limitations and Restrictions
This chapter contains information that you should consider before you use this Fabric OS release.
10.1 Scalability
All scalability limits are subject to change. Limits may be increased once further testing has been completed, even after
the release of this version of the Fabric OS software. For current scalability limits for Fabric OS software, refer to the
Brocade SAN Scalability Guidelines for Brocade Fabric OS 8.X document.
10.2 Compatibility/Interoperability
Brocade SANnav Management Portal allows management of one or more SAN fabrics that are in the same or different
geographical locations and supports up to a maximum of 15,000 (15K) physical SAN ports. For environments that are
larger than 15K ports, users can deploy multiple SANnav Management Portal instances.
Brocade SANnav Global View is a higher-level management application that provides visibility, summarization and
seamless navigation across multiple SANnav Management Portal instances. Users can drill-down to any individual
SANnav Management Portal instance from SANnav Global View to perform detailed monitoring, investigation, and
troubleshooting.
The SANnav Management Portal 2.0.x supports managing SAN switches running Fabric OS up to v8.2.2x. Compatibility
with FOS versions can be found in the SANnav Management Portal 2.0.x Release Notes. FOS v8.2.2a and later require
FOS EULA acceptance during firmware migration. The SANnav Management Portal 2.0.x does not support firmware
migration from FOS v8.2.2a and later to any FOS version. Use the SANnav 2.1 Management Portal 2.1.x for firmware
migration. Alternatively, use WebTools or the CLI in FOS v8.2.2a or later for firmware migration.
Broadcom FOS-822d-RN100
32
Network Advisor Professional Plus – A SAN management application designed for medium-size businesses or
departmental SANs for managing up to 36 physical or virtual fabrics (FOS) and up to 2560 switch ports. It supports
Brocade director products (for example, X6-4, DCX 8510-4/DCX-4S, 48Ks), FC switches, Fibre Channel over IP (FCIP)
switches, Fibre Channel Routing (FCR) switches/Integrated Routing (IR) capabilities, Fibre Channel over Ethernet
(FCoE)/DCB switches, and QLogic and Emulex HBAs/CNAs.
Network Advisor Enterprise – A management application designed for enterprise-class SANs for managing up to 100
physical or virtual fabrics and up to 15,000 switch ports. Network Advisor Enterprise supports all the hardware
platforms and features that Network Advisor Professional Plus supports, and it adds support for the Brocade
directors (X6-8, DCX 8510-8/DCX) and Fiber Connectivity (FICON) capabilities.
More details about new enhancements for Brocade Network Advisor can be found in the Network Advisor 14.4.5 release
notes, Network Advisor 14.4.5 user guide, and Network Advisor 14.4.5 installation, migration, and transition guides.
NOTE
Brocade Network Advisor 14.4.4 or later is required to manage switches running Fabric OS 8.2.2 and later.
FOS v8.2.2a and later require EULA acceptance. Brocade Network Advisor 14.4.4 does not support firmware
migration from FOS v8.2.2a and later to any FOS version. Use Brocade Network Advisor 14.4.5 for firmware
migration.
The Brocade Network Advisor seed switch should always have the highest FOS version used in the fabric.
Broadcom FOS-822d-RN100
33
For a list of the effective end-of-life dates for all versions of Fabric OS software, visit the following Brocade website:
https://www.broadcom.com/support/fibre-channel-networking/eol.
You can download the MIB files required for this release from the Downloads area of the myBroadcom site. To
download the Brocade-specific MIBs, you must have a user name and password. Perform the following steps.
1. Go to https://www.broadcom.com/mybroadcom/, click Login, and enter your username and password.
If you do not have an account, click Register to set up your account.
2. Select Customer Support Portal > DocSafe (Software/Document Downloads).
3. Enter the product name or the software version number in the Search box. For example, the following search is
for software and documentation files for software version 8.2.
YANG is a standard data modelling language that defines the data sent over the FOS REST API. Each FOS REST API
module is defined in a YANG module file with a .yang name extension. To download the Brocade FOS-specific YANG files
from the Brocade Technical Support website, you must have a user name and password. Perform the following steps to
obtain the YANG files.
1. Go to https://www.broadcom.com/mybroadcom/, click Login, and enter your username and password.
If you do not have an account, click Register to set up your account.
2. Select Customer Support Portal > Documents and Software.
3. Enter the product name or the software version number in the Search box.
4. When the list of files appears, clear the Documents box.
5. Navigate to the link for the Fabric OS package file, either for Windows or for Linux, and download it to your disk.
6. Unzip or untar the Fabric OS package file; the yang.tar.gz file contains the collection of YANG module files that
this FOS release version supports. Untar the yang.tar.gz file to obtain individual YANG module files.
Alternatively, download the YANG files for a specific FOS version from https://github.com/brocade/yang
Broadcom FOS-822d-RN100
35
10.3 Important Notes
10.3.1 FCoE
The following topologies for FCoE on the FC32-64 are not supported with FOS 8.2.2:
Cisco UCS server directly connected to the FC32-64 without a Fabric Interconnect module.
Cisco UCS server with a Fabric Interconnect module connected to the FC32-64 via a Nexus 5000 series switch in
between. Neither running FCoE NPV mode nor L2 switching mode on the Nexus 5000 is supported.
10.3.2 FC-NVMe
FOS 8.1.0 or later is required to support FC-NVMe devices.
FOS 8.2.1 or earlier does not support FC-NVMe over FCR configurations. FOS 8.2.1b supports FC-NVMe in edge fabric
to edge fabric over FCR configuration.
10.3.4 VM Insight
VM Insight is supported on the Brocade G610, G620, G630, and X6 running FOS 8.1.0 and later. Brocade Gen 5 Fibre
Channel platforms support frames with the optional FC Application Header for VM Insight to pass through. The
Brocade 7840 and SX6 running FOS 8.1.0 support the Application Header in the FCP emulating tunnel. The FCP
emulating tunnel or FICON emulation is not supported in other extension platforms or earlier firmware.
Nonemulating tunnel on extension platforms support pass through of the Application Header.
VM Insight is not supported across FCR, but frames with the Application Header may traverse through FCR.
FOS 8.2.0 supports VM performance metrics in flows on the ingress F_Port only. The Brocade G610 and G620
support FC metrics. Brocade X6 Directors support both FC metrics and SCSI IO metrics.
Legacy static flow does not monitor SCSI IOPS statistics for frames with the Application Header.
Duplicate subflow entries are displayed after a switch HA failover or multiple restarts of VM traffic without clearing
the status. The workaround is to use the flow --reset sys_mon_all_vms command.
FOS 8.2.0 does not support VM Insight for FC-NVMe traffic.
Broadcom FOS-822d-RN100
36
10.3.5 ClearLink Diagnostics (D_Port)
Fabric OS 8.2 supports D_Port tests between two Brocade switches and between Brocade switches and Gen 5
(16Gb/s) and Gen 6 (32Gb/s) Fibre Channel adapters from QLogic and Emulex. The following are specific adapter
models and driver versions tested by Brocade with Fabric OS 8.2 for ClearLink. 7
Emulex 16G Emulex 32G QLogic 16G QLogic 32G
Adapter Adapter Adapter Adapter
Adapter Model LPe16002B-M6 LPe32002-M2 QLE2672 QLE2742
Adapter Firmware 11.4.204.20 11.4.142.23 v8.05.44 v8.05.44
Adapter Driver 11.4.142.23 11.4.204.8 STOR Miniport STOR Miniport
9.1.17.21 9.1.17.21
The D_Port long-duration test can be run only on one port at a time.
Long-duration electrical loopback tests are not supported.
D_Port tests on 4x32GFC breakout QSFP optics (P/N 57-1000351-01) and 128GFC non-breakout QSFP optics (P/N 57-
1000331-01) have the following restrictions:
D_Port for these modules in X6 ICL ports is supported without electric or optical loopback tests.
D_Port on any user port connected by a QSFP require all four user ports within the same QSFP to be in D_Port mode.
D_Port tests require all user ports in a QSFP to be in the same logical switch.
Dynamic or On-Demand D_Ports are not supported on the user ports in these modules.
If a D_Port test between a Brocade switch and an Emulex adapter is stopped shortly after the test has started, the
adapter firmware may display “No FC Cables connecting the port to switch.” The workaround is
to restart the D_Port test until completion.
If a D_Port test is run through optical media for long distance but the ports are not configured for long distance,
D_Port test can fail without a pre-check error message about the configuration mismatch.
7Adapter firmware or driver versions that are later than the ones listed in the table may not work.
Broadcom FOS-822d-RN100
37
10.3.8 Ingress Rate Limiting
Fabric OS 8.2 does not support ingress rate limiting on Brocade Gen 6 (G610, G620, G630, or X6) platforms.
10.3.10 Extension
IP extension (IPEXT) between a Brocade 7840 and an SX6 blade is supported only if the 7840 is running FOS 8.0.2 or
later. FCIP extension between a Brocade 7840 with FOS 8.0.2 or later. An SX6 blade with FOS 8.0.2 or later is
supported. Extension between a Brocade 7840 or SX6 and a Brocade 7810 is supported only if the 7840 or SX6 is
running FOS 8.2.0 or later. The following table documents the combinations.
Site1 Switch/Blade Site1 Firmware Site2 Switch/Blade Site2 Firmware Supported
7840 8.0.2 or later 7840 8.0.2 or later Both FCIP and IPEXT traffic
SX6 8.0.2 or later 7840 8.0.2 FCIP traffic but not IPEXT traffic
SX6 8.0.2 or later 7840 8.0.2 or later Both FCIP and IPEXT traffic
SX6 8.0.2 or later SX6 8.0.2 or later Both FCIP and IPEXT traffic
7840 8.2.0 or later 7810 8.2.1 or later Both FCIP and IPEXT traffic
SX6 8.2.0 or later 7810 8.2.1 or later Both FCIP and IPEXT traffic
Do not to configure the HA VE pair (VE16, VE26), (VE17, VE27), (VE18, VE28), and so on, where each VE in the pair is
in a different LS with a different traffic policy (port-based routing and exchange-based routing). The workaround is
to configure different HA VE pairs such as (VE16, VE27), (VE17, VE26), and so on when putting each VE pair in a
different LS with a different traffic policy.
When Non-Terminate TCP (NT-TCP) is enabled on traffic control lists (TCLs) and a firmware downgrade to FOS 7.4.1d
is attempted on the Brocade 7840, the downgrade will be blocked. Users must remove NT-TCP from the TCLs with
NT-TCP enabled in order to downgrade the firmware. After the firmware is downgraded to FOS 7.4.1d, users can re-
enable the NT-TCP flag.
Nondisruptive firmware downloads for IP extension support nondisruption to IP traffic for all terminate TCP
connections. UDP and non-terminate TCP traffic may be disrupted during HCL.
Broadcom FOS-822d-RN100
38
After firmware downgrade completion, the Brocade 7840 needs a switch reboot and the SX6 needs a blade power-
cycle. HCL is not supported on firmware downgrades.
When downgrading from FOS 8.1.0a to an earlier release during HCL, the following message may be seen. This
message can be ignored and has no functional impact.
[ESM-1100], 343, SLOT 1 FID 128, WARNING, switch0, esm_cfg_ip.c:2226 Could not
get PMTU info from cfgdb
If a Brocade 7840 or Brocade X6 Director with an SX6 blade in a non-VF is assigned a fabric ID other than 128, then
during a heavy traffic load, the back-end ports on the 7840 and SX6 may encounter credit loss, which can result in
traffic disruption over the VE ports. This is tracked as Defect 660208.
If a 10 Gb/s port is configured on a base configuration of Brocade 7810 with FOS v8.2.2 or later without an Extension
Upgrade license, users may see configuration replay errors after the firmware on the 7810 is downgraded to FOS
v8.2.1x.
Some 10G SFP's can run at the 1G speed even though FOS 8.2.2d does not support the 1G setting. The unsupported
setting causes issues. FOS 8.2.0 added a check to verify that the configured port speed matches the installed SFP;
and displays a RASlog message if it does not match. Starting in FOS 8.2.1, when a 10G SFP is placed in a port
configured to 1G, FOS displays the RASlog message and does not bring the port online.
To resolve this issue, you must replace the SFP with a 1G SFP; or configure the port speed to 10G to match the SFP
speed.
Broadcom FOS-822d-RN100
39
vTap and CS_CTL are mutually exclusive on a fabric switch. If CS_CTL is enabled on one port, the entire switch cannot
enable vTap. An F_Port trunk supporting CS_CTL must have all ports in the trunk group enabling CS_CTL. Similarly, in
order to enable vTap, all ports in an F_Port trunk must have CS_CTL disabled. In addition, the master port of a trunk
should remain the same between CS_CTL enabling and disabling. If this sequence is not followed, vTap may remain
active even after CS_CTL is enabled on an F_Port, or the error message “Disable QoS zones error” may be
observed when enabling vTap. A suggested method is to use the following sequence:
1. When enabling CS_CTL mode, enable it on all slave ports, followed by enabling it on the master port,
noted as port M.
2. When disabling CS_CTL mode, disable all active ports in the trunk, except the master port M. Disable
CS_CTL mode on port M. Enable all ports in the trunk followed by disabling CS_CTL mode on the
remaining ports.
3. When CS_CTL is enabled on a port without any connection, after rebooting and disabling CS_CTL, vTap
cannot be enabled. The workaround is to enable the port as a SIM port after disabling CS_CTL and then
to toggle the port and remove the SIM port configuration.
vTap and in-flight encryption or compression compatibility are supported only on the following platforms:
Brocade DCX 8510, X6, G620, G630, and 6520. On DCX 8510 and 6520 platforms, the chassis configuration “vTap and
Encryption/Compression Coexistence Mode” must be enabled when ports with vTap enabled and ports with in-flight
encryption or compression enabled belong to the same ASICs. Refer to the hardware installation guides for these
platforms for the port-to-ASIC mapping boundary.
When “vTap and Encryption/Compression Coexistence Mode” is enabled, the total IOPS on the same ASIC is limited
to 250,000. If the IOPS exceeds the limit, the vTap flow will be deactivated.
When “vTap and Encryption/Compression Coexistence Mode” is enabled, the effective default zone access mode
must not be “All Access.”
Running the flow --show sys_analytics_vtap command when vTap and QoS High compatibility mode is
enabled but the vTap flow is not active may display the following message incorrectly: “Enable vTap and QoS
High Priority Zone Compatibility Mode to active vTap flow. Please use the
configurechassis command to enable this compatibility mode.” This is tracked as Defect
604429.
After a configuredownload followed by switchenable or a flow statistics reset on the Brocade X6 and
G620, MAPS may incorrectly report a VTAP IOPS > 250,000 violation.
AMPOS 2.2.0 or later is required to support FC32-64 blades. Users should upgrade the Brocade Analytics Monitoring
Platform to AMPOS 2.2.0 or later before adding FC32-64 blades to the X6.
Broadcom FOS-822d-RN100
40
IO Insight metrics are supported on ingress and egress ports on the Brocade X6 and on egress ports on
Brocade G620 and G630 switches. They are not supported on Brocade G610 switches.
Activating a Flow Monitoring flow on an egress port on the Brocade G610 with the -frametype parameter may
cause a resource not available error.
FC-NVMe flow IO Insight metrics are supported with a Flow Monitoring flow on a port defined on the Brocade G630
and FC32-64 blade only. Users must use the -nsid parameter with the flow --create command to monitor
FC-NVMe flows. Either a valid Name Space ID (NSID) must be used or the all keyword must be used to select all
valid NSIDs.
When a flow is created with the -frametype parameter, FC-NVMe traffic is included in the metrics for the
following SCSI frame types: SCSI, SCSITur, SCSIXferrdy, and SCSIGoodStatus.
Flow Mirroring is not supported on QSFP ports (port 96 to 127) on the Brocade G630 with Virtual Fabric (VF) mode.
It is supported in non-VF mode only.
Mirror ports are not supported on QSFP ports (port 96 to 127) on the Brocade G630. Enabling a mirror port on these
ports will disable the ports.
If a flow is imported to MAPS and configured with incorrectly configured flow metrics thresholds, a high frequency
violation of the thresholds may result in very slow display of the RASLOG alerts for the violations.
10.3.13 FICON
For FICON-qualified releases, refer to the Additional Considerations for FICON Environments section of the Appendix for
details and notes on deployment in FICON environments. (This appendix is included only for releases that have
completed FICON qualification.)
10.3.14 MAPS
MAPS monitoring of UCS server login does not support the FENCE action even though the mapsrule command does
not block the configuration.
10.3.15 Miscellaneous
If the ambient temperature is above the recommended operational limit, the power supply units may shut down, in
particular when the ambient temperature is above 62°C for Brocade X6 Directors. This will result in the switch being
shut down without any warning. Refer to the Brocade G620 Hardware Installation Guide and the Brocade X6-8/X6-4
Hardware Installation Guide for the recommended ambient temperature limits for the switches.
After a power supply unit is removed from a Brocade G620, the historyshow command may miss the entries for
this FRU removal or insertion event. In addition, the RASLog error message EM-1028 may be logged when the power
supply is removed. This condition can be corrected by power-cycling the switch.
After running offline diagnostics mode 1 on QSFP ports, a Brocade G620 must be rebooted before operational use.
All links in an ICL QSFP connection on a Brocade X6 Director must be configured to the same speed using the
portcfgspeed command from one of the following supported speeds: 16Gb/s, 32Gb/s, or ASN. To connect an ICL
from an X6 with a 4x32GFC breakout optic (P/N 57-1000351-01) or a 4x16G FC optic to a 4x16G FC optic in a
DCX 8510, the X6 port’s speed must be set to 16Gb/s.
When the zoning database size exceeds the maximum supported limit, 2 MB for directors and 1 MB for fixed-port
switches, a firmware upgrade from FOS 8.0.x to FOS 8.1.0a or later may be blocked. Users should run the cfgSize
command to make sure that the “Zone DB max size” is not exceeded.
ASN is not supported with 4x32GFC breakout optics (P/N 57-1000351-01).
Broadcom FOS-822d-RN100
41
When connecting 4x32G FC breakout optics (P/N 57-1000351-01) to 32Gb/s SFP peer ports on Gen 6 platforms,
ports may auto-negotiate to 16Gb/s after switchdisable and switchenable on the Gen 6 platforms with
32Gb/s SFP ports. To avoid this issue, the Gen 6 platforms with 32Gb/s SFPs should be upgraded to FOS 8.2.0 or later
or to FOS 8.1.2b or later. This issue is more likely to occur when the Gen 6 platforms with 32Gb/s SFPs are X6
directors.
Brocade G630 LEDs illuminate amber and green during power-up.
When launching Web Tools over an HTTPS connection and a security warning message for an untrusted certificate
pops up, the pop-up message should be responded to within 20 seconds.
When upgrading to FOS 8.1.0b or later and HTTPS is enabled, administrators must have the Certificate Authority
(CA), intermediate, and root certificates installed to ensure that the chain of certificate validation is successful.
HTTPS will be disabled in FOS 8.1.0b or later if the chain of certificate validation fails. To verify if the CA is correct
and the CA chain validation is successful, issue the following command on a Linux server:
openssl verify -CAfile ca.pem servercert.pem
In the example above, ca.pem is the CA certificate and servercert.pem is the switch certificate. If the switch
certificate is signed by the intermediate certificate, use the completed chain CA certificate; otherwise, use the root
certificate.
When replacing a FC32-64 blade with a FC32-48 blade, flexport and FCoE configurations should be removed before
the FC32-64 blade is removed.
The output of CLI command sfpShow or any other interfaces to retrieve information from 32Gb/s 100m QSFP (Part
Number 57-1000490) does not match the Part Numbers on the media sticker labels. The output shows Part Number
57-1000351 instead. This does not affect operation of the optics.
Broadcom FOS-822d-RN100
42
Chapter 11: Security Vulnerability Fixes
This section lists the Common Vulnerabilities and Exposures (CVEs) that have been addressed. Each CVE is identified by
the CVE ID number.
The following CVEs have been addressed in FOS v8.2.2c:
CVE-2016-3189 - Use-after-free vulnerability in bzip2recover in bzip2 1.0.6 allows remote attackers to cause a denial
of service (crash) via a crafted bzip2 file, related to block ends set to before the start of the block.
CVE-2017-15670 - The GNU C Library (aka glibc or libc6) before 2.27 contains an off-by-one error leading to a heap-
based buffer overflow in the glob function in glob.c, related to the processing of home directories using the ~
operator followed by a long string.
CVE-2017-15804 - The glob function in glob.c in the GNU C Library (aka glibc or libc6) before 2.27 contains a buffer
overflow during unescaping of user names with the ~ operator.
CVE-2016-4429 - Stack-based buffer overflow in the clntudp_call function in sunrpc/clnt_udp.c in the GNU C Library
(aka glibc or libc6) allows remote servers to cause a denial of service (crash) or possibly unspecified other impact via
a flood of crafted ICMP and UDP packets.
CVE-2019-11478 - SACK Slowness (Linux < 4.15) or Excess Resource Usage (all Linux versions). A sequence of
specifically crafted selective acknowledgements (SACK) may cause a fragmented TCP queue, with a potential result
in slowness or denial of service.
CVE-2018-6447 - A Reflective XSS Vulnerability in HTTP Management Interface in Brocade Fabric OS versions before
Brocade Fabric OS v9.0.0, v8.2.2c, v8.2.1e, v8.1.2k, v8.2.0_CBN3, v7.4.2g could allow authenticated attackers with
access to the web interface to hijack a user’s session and take over the account.
CVE-2020-15369 - Supportlink CLI in Brocade Fabric OS Versions v8.2.1 through v8.2.1d, and 8.2.2 versions before
v8.2.2c could expose remote users credentials. An authenticated user could obtain the exposed password
credentials to gain access to the remote host.
CVE-2020-15371 - Brocade Fabric OS versions before Brocade Fabric OS v9.0.0, v8.2.2c, v8.2.1e, v8.1.2k,
v8.2.0_CBN3, contains code injection and privilege escalation vulnerability. The vulnerability could allow an
unauthenticated, remote attacker to perform via seccryptocfg templates to perform code injection and privilege
escalation.
CVE-2020-15372 - A vulnerability in the command-line interface in Brocade Fabric OS before Brocade Fabric OS
v8.2.2a1, 8.2.2c, v7.4.2g, v8.2.0_CBN3, v8.2.1e, v8.1.2k, v9.0.0, could allow a local authenticated attacker to modify
shell variables, which may lead to an escalation of privileges or bypassing the logging.
CVE-2020-15373 - Multiple buffer overflow vulnerabilities in REST API in Brocade Fabric OS versions v8.2.1 through
v8.2.1d, and 8.2.2 versions before v8.2.2c could allow remote unauthenticated attackers to perform various attacks.
CVE-2020-15374 - Brocade Fabric OS before v9.0.0, v8.2.2c, v8.2.1e, v8.1.2k, v8.2.0_CBN3, v7.4.2g, contains an
improper input validation weakness in the command line interface when secccrypptocfg is invoked. The vulnerability
could allow a local authenticated user to run arbitrary commands and perform escalation of privileges.
CVE-2020-15375 - Rest API in Brocade Fabric OS v8.2.1 through v8.2.1d, and 8.2.2 versions before v8.2.2c is
vulnerable to multiple instances of reflected input.
Broadcom FOS-822d-RN100
43
The following CVEs have been addressed in FOS v8.2.2:
CVE ID: CVE-2018-15473 - OpenSSH through 7.7 is prone to a user enumeration vulnerability due to not delaying
bailout for an invalid authenticating user until after the packet containing the request has been fully parsed, related
to auth2-gss.c, auth2-hostbased.c, and auth2-pubkey.c.
CVE ID: CVE-2017-15906 - The process_open function in sftp-server.c in OpenSSH before 7.6 does not properly
prevent write operations in read only mode, which allows attackers to create zero-length files.
CVE ID: CVE-2018-0734 - The OpenSSL DSA signature algorithm has been shown to be vulnerable to a timing side
channel attack. An attacker could use variations in the signing algorithm to recover the private key.
CVE ID: CVE-2018-0737 - The OpenSSL RSA Key generation algorithm has been shown to be vulnerable to a cache
timing side channel attack. An attacker with sufficient access to mount cache timing attacks during the RSA key
generation process could recover the private key.
CVE ID: CVE-2017-3737 - OpenSSL does not properly handle SSL_read() and SSL_write() while being invoked in an
error state, causing data to be passed without being decrypted or encrypted directly from the SSL/TLS record layer.
Broadcom FOS-822d-RN100
44
Chapter 12: Defects
Condition: Spurious power supply readings may happen when the BR6520 or
BR7840 is running with a single power supply and with FOS v8.2.2c.
Workaround: BR6520 or BR7840 running FOS 8.2.2c should always have two power
supplies installed and operating to avoid a potential spurious power
reading.
Condition: When using FW extended tunnels at higher IO rates and higher WAN
latency, there are IOs that are passed through instead of having
Transfer Ready generated.
Broadcom FOS-822d-RN100
45
Defect ID: FOS-822906
Symptom: Interactive firmwaredownload presents the EULA but does not allow
the user to accept it.
Workaround: Reverse the option order via firmwaredownload "-sn", "-sb" etc.,
such that the "s" option is not at the end.
Symptom: Performance degradation for FICON flows after FOS upgrade to FOS
8.2.1 or higher
Condition: When running IO over 7840 or SX6 FCIP Tunnels with FICON
emulation enabled.
Broadcom FOS-822d-RN100
46
Defect ID: FOS-822104
Symptom: User may experience FCIP ingress traffic stopped due to no more
internal credits available and associated C3-1014/C3-1015 RASLOG
messages on a 7840 platform or C4-1014/C4-1015 RASLOG messages
in a chassis with an SX6 blade. In the case of an SX6 blade, the blade
will be faulted after multiple attempts to recover internal credits.
Condition: This stems from a timing issue either during tunnel disable or tunnel
down processing where credits from FCIP back to FTNL aren't sent.
This leads to permanent flow control on the peer side and the credit
loss on the peer side FC ingress side.
Workaround: Disable D-port on the 16G HBA. Disable D-port or Fabric Assigned
WWN feature on 32G HBA.
Broadcom FOS-822d-RN100
47
Defect ID: FOS-821627
Symptom: Message of the day (MOTD) is not displayed upon connecting to the
switch.
Symptom: Following an abrupt power failure on port blade, the switch continues
to access the blade via PCI causing subsequent system level failures
such as CP reboot, hung CP, or a blade that cannot be powered on.
Condition: Abrupt power loss on port blade is mostly seen with SX6 port blade.
Enhancements have been added in FOS v8.2.2d and later to reduce
the timing window for the undesired system level side effects caused
by SX6 sudden power loss.
Workaround: Avoid using supportsave as monitoring tool, but only use it for debug
data gathering.
Broadcom FOS-822d-RN100
48
Defect ID: FOS-820884
Symptom: BR6547 is not using credit value configured on peer switch using
portcfgeportcredits command
Symptom: High CPU load observed on switch once a connection via WebTools is
made with https.
Symptom: CLI "flow --show" no longer displays any of the customized flows and
flow monitor deactivate fails with " ioctl failed" message.
Broadcom FOS-822d-RN100
49
Defect ID: FOS-820674
Condition: Special character in the BNA password, such as "$", lead to this
supportsave failure.
Symptom: CLI "userconfig --change root -e yes" cannot manage the target
account with error message of "conflicting LF permission".
Condition: This occurs when the default account parameters from user defined
accounts are changed.
Broadcom FOS-822d-RN100
50
Symptom: Customer may encounter CP resets triggered by SysRq, along with a
display of numerous "Help" messages seen on the console.
Condition: This results from the SysRq request that is triggered from spurious
BREAK signal initiated by the Terminal Server.
Workaround: Run the following command on the Active and/or Standby CP.
echo "0" > /proc/sys/kernel/sysrq To make this persist across CP
reboots and hafailover, change the kernel.sysrq setting in
/etc/sysctl.conf file from 1 to 0. (i.e This setting in /etc/sysctl.conf file
should read "kernel.sysrq = 0")
Symptom: CLI configdownload failed for filter "snmp" with "Bad Syntax" and
"Failed to Parse" errors.
Condition: This is seen when using a configfile uploaded from FOS9.x with keys
not supported in FOS8.x
Condition: When automating commands through plink (part of putty), and the
return code coming from the switch for the command licenseshow is
"1". This started appearing in v8.x code. Prior to that, the return code
was "0".
Workaround: Pipe the output to "more" when running the command to get a
return code of "0".
Broadcom FOS-822d-RN100
51
Technical Severity: High Probability: Low
Workaround: Enable the EX-port trunk only when the switch is not busy, to avoid
this rare timing issue.
Condition: This issue is seen rarely when a specific zone configuration is enabled
from Webtool and overflow the buffer size allocated by zone
daemon.
Condition: Missing information was added to man page, for example dnsconfig.
Broadcom FOS-822d-RN100
52
Reported In Release: FOS8.2.1a Technology: Component
Condition: When a FPGA blade status register bit is delayed during a hafailover
window, CP interprets that as a blade is not present. This is a very
rare incident.
Symptom: Switch panic when doing fosexec --fid all -cmd "portflagsshow" .
Condition: credit zero stats were not correct when port joins or leave trunk.
Symptom: SX6 AP blade fault occurs after internal backend port is disabled or a
disruptive failover even though it reports HA-IN-SYNC.
Broadcom FOS-822d-RN100
53
Condition: When the active CP has a non-default blade mode (either VE-MODE
set to 20VE, or APP-MODE set to hybrid) and the standby CP is
installed for the first time, or netinstalled, the standby CP will have
the wrong app-mode.
Recovery: Reboot the standby CP before any failover attempts are made.
Symptom: Switch panics after various daemons, such as fcpd, tsd, webd,
terminate while accessing configuration database resource key.
1. Specific 3rd party devices flood the switch with GID_PN requests,
leading to delays and impact monitoring applications. 2. Maps put out
alert about Tx Power of SFP being 0.
Broadcom FOS-822d-RN100
54
Condition: 1. The flood of GID_PN only happens on switches that have QSFP,
QSFPP, QSFP28(YTA) and running FOS v8.1.2g/later, v8.2.1c/later
and v8.2.2/later.
2. Maps alert can happen on any SFP type and any release.
Condition: Issue will only be observed on GEN 5 platforms that have ASC enabled
for BSL. The switch needs to also be monitored by one or more
management applications. A race condition between the BSL CLI
collection, data compression operation and external management
applications can cause the weblinker (http demon) to hang. The
likelihood of this occurring will increase with the amount of data
being collected and compressed by BSL.
Condition: Updated man page to removed the statement that says fabric vision
license required
Broadcom FOS-822d-RN100
55
Reported In Release: FOS8.2.2 Technology: Flow Vision: Flow
Mirroring
Symptom: After code upgrade, the user defined flows are not showing up in the
admin level command of "flow --show";
Workaround: Use the "flow --show all" as admin to see the user defined flows.
Symptom: After timezone / date change, the next day's Brocade Support Link
(BSL) data collected will be interpreted incorrectly.
Condition: This occurs if the switch is not rebooted following timezone / date
change.
Symptom: fcprlsprobe timing out on shared area ports with PLOGI being sent to
invalid PID ending in FF.
Condition: Running 'fcprlsprobe' on a port with a PID with a base AL_PA of 0x40,
0x80, or 0xc0.
Workaround: Run fcprlsprobe only on ports with a PID with base AL_PA of 0x00.
Broadcom FOS-822d-RN100
56
Symptom: The frequency of the stats collection has to be aligned to the wall
clock's 00mts or 30mts. For example: 11:00, 11:30, 12:00, 12:30. But
due to an issue in the handling of drift, the Brocade Support Link (BSL)
data collection may not happen in the wall-clock aligned time, but
could be random. This can impact the FA's data co-relation logic.
Condition: This may occur with any Time zone change or system date change
(using CLI command date) or any NTP server sync that results in drift
greater than 30 seconds.
Workaround: Any Time zone change or system date change ( using date command )
must be accompanied by system reboot for the BSL data to be
properly interpreted right.
Symptom: From BNA, when the user adds the rule HA_SYNC with operator ge, g,
for the active policy, the system does not generate an error as would
be expected.
Condition: This occurs with BNA, when adding the rule HA_SYNC with operator
ge, g.
Broadcom FOS-822d-RN100
57
Defect ID: FOS-819311
Condition: When use Web Tools, user may see the irrelevant message.
Symptom: Extension device may hit out of memory condition signified by the
following RAS Log: XTUN-1001 FTNL Tunnel 24 Memory allocation
failed tracker 3/831. The extension device may also encounter DP
panics once memory is depleted.
Symptom: CLI command devicelogin --show output may reflect some ports
missing from the CLI output.
Condition: This may occur with UCS device ports with a base address ending in
0x40 0x80 or 0xc0.
Broadcom FOS-822d-RN100
58
Defect ID: FOS-818655
Symptom: Windows host in cascaded AG G610 does not see target disk. It can
also occur in non-cascaded AG environment but less likely.
Workaround: Avoid bouncing ports after ahreboot. Instead of port bounce, a cold
boot can be done, after which port bounces are fine.
Symptom: For the configupload command, the -force flag when saving to the
local file system does not work. It still prompts the user if they would
like to overwrite previous file.
Condition: This is encountered when attempting to force save the config to local
file: configupload -force -local
Broadcom FOS-822d-RN100
59
Defect ID: FOS-817953
Symptom: After making zone changes in the fabric, customer may encounter
one or both of the following: 1. Defined zone configuration DB is
removed, HA Sync is lost, and verify error seen on standby CP. 2.
Fabric is segmented with reason "segment zone conflict" If the zone
data base is not repaired before issuing a cfgEnable to activate the
new zone definition, it can result in an impact to traffic.
Condition: This issue can be seen with FOS8.2.1, 8.2.1a, 8.2.1b, 8.2.1c,8.2.1d,
8.2.2, 8.2.2a or 8.2.2b. When a very specific 3rd party device sends
the Get Active Zone Size (GAZA) / Get Zone Size (GZS) CT command
with limited response size. Zone database is corrupted after
processing these commands, and an extra semicolon is left at the
end of the zone member list.
Workaround: Avoid using "network fcp zone show" from the device, which triggers
GAZS/GZS request to fabric.
Recovery: If the defined zoning database was truncated but no zone commit
operations were performed:
Option 1: From another switch in the fabric that has not been
corrupted with the extra semicolon, create a "dummy zone" and then
perform a "cfgEnable" command on the effective cfgname to restore
the zoning database across the fabric.
Option 2: On the switch that has the added semicolon in the zone
data base, perform an "haFailover" if it is a director or an "haReboot"
if it is a fixed port switch.
Option 3: Coldboot the switch with the bad zonset. If the bad zonset
was pushed to the rest of the fabric, and the zoning data base is
erased:
Broadcom FOS-822d-RN100
60
zone database should be restored. Next, create a "dummy
zone" and perform a "cfgEnable" command on the effective
cfgname to restore the zoning database across the fabric.
Workaround: Do not run parallel support save or asic related dump when system is
under heavy load.
Symptom: Need to perform switch excess power check and shutdown for
BR7840 and 6520.
Condition: This may happen under rare situation that may cause the board to
draw excessive power
Broadcom FOS-822d-RN100
61
Workaround: A CRITICAL raslog EM-1229 is logged when the power consumption is
detected to be within 20% limit of reaching the threshold for
excessive power. The user is advised to power down the system and
contact Brocade support to have the system replaced
Recovery: In the event of that the EM-1229 raslog goes unheeded and the
power drawn crosses the excessive power threshold then the system
will log raslog EM-1230 and power off the system. The user must
contact Brocade support to have the system replaced
Broadcom FOS-822d-RN100
62
Defect ID: FOS-816300
Symptom: IPEX LAN TCP connection will report failed in the application.
Condition: When there is packet loss on the LAN with Jumbo frames enabled,
the LAN TCP receive process may stall causing LAN TCP connections
to timeout.
Symptom: Switch panic observed after essd daemon access freed memory.
Condition: During high CPU time (for example, during lots of SNMP requests),
inter-switch communication can be delayed and cause a daemon
and/or switch crash.
Broadcom FOS-822d-RN100
63
Defect ID: FOS-815189
Recovery: Manually unmap the wrong ports from N-port 0 and then map the
correct ports to N-port 0. Also, the unmapped ports may need to be
converted to N-ports (portcfgnport) and have mapping applied to
them.
Symptom: The BR6520 switch gets into a rolling reboot loop and needs a manual
intervention to recover.
Condition: When a bad asic access caused the PCI bus to hang. This impacts
BR6520 switches only.
Broadcom FOS-822d-RN100
64
Defect ID: FOS-814484
Symptom: Creating a user account with an uppercase password causes the login
to fail.
login: USERID
password: (PASSW0RD)
LOGIN INCORRECT
Condition: This applies to Brocade Switch BR7810 running FOS 8.x and above.
Broadcom FOS-822d-RN100
65
Condition: This occurs due to a timing issue when CLI debug command is run
early in the switch initialization phase. This applies to FOS 8.x and
above.
Symptom: The user will observe the Tunnel bounce when changing circuit
bandwidth.
Condition: This stems from a bug during PMTU busy retry and applies to FOS 8.x
and above.
Symptom: BR7840 or SX6 FCIP Tunnel failure or disable can result in DP reset
Condition: Small timing window when FC frames can be received on the FCIP
tunnel after the tunnel is reported as going offline. It is occasionally
observed on FOS v8.x.
Condition: This issue is reproducible on Port-3/0 only after running statsclear CLI.
Broadcom FOS-822d-RN100
66
Defect ID: FOS-812889
Symptom: SX6 blade is not powered-on, when initializing the blade, after
EM_INCONSISTENT failure during HA failover.
Symptom: SNMP community strings with basic SNMPv1 queries are not
recognized.
Condition: When there is a transaction already open in a switch (ex: via CLI) and
another transaction starts (distribution via ACA, SFC, UFC, RCA
through WT/BNA) in a remote switch in the same fabric
simultaneously. This is a timing issue when a customer creates
multiple zoning transactions on different switches at the same time.
Broadcom FOS-822d-RN100
67
Recovery: The switch recovers after the ASSERT.
Workaround: Identify the misbehaving devices and remove them from the fabric.
Recovery: The reboot that results from out-of-memory recovers the switch. If
high IU memory usage is detected before the out-of-memory
condition, hafailover can temporarily recover and prevent the
unexpected switch reboot.
Symptom: Missing N-port info from "ag --show" after toggle N-ports.
Condition: After toggling N-ports that connect to Gen5 and Gen4p , "ag --show"
has missing N-port info "Attached_Switch", "Switch F-port" and
"IP_Addr". This is seen on FOS v8.x and later.
Broadcom FOS-822d-RN100
68
Condition: Only when tacacs+ is configured
Workaround: Avoid reboot switch if gateway addess is set with 12 full digits until
upgrade. Or use less than 12 digits gateway address
Recovery: After each reboot customer has to login via serial cable to make any
changes.
Symptom: Silent frame drops may be encountered on Brocade 6520 running FOS
v7.4.2c.
Condition: This occurred because the BE link DID check bit was set in the past,
which led to frame drops over that particular BE link.
Symptom: D-Port test fails with Protocol Error on switch end and on HBA, EL
failed despite the overall result states Passed
Condition: D-port test gets failed/ stuck in IN_PROGRESS when the test is
executed on the QSFP links connected to GEN5 HBAs.
Broadcom FOS-822d-RN100
69
Defect ID: FOS-803567
Symptom: Brocade Gen6 Director switches may encounter one or both of the
following occurrences:
Condition: This can only occur on X6-8 or X6-4 director switches after upgrading
to FOS 8.2.0 or later versions from an earlier FOS version, and the
PORTMAP table grows in size >= 1024.
Broadcom FOS-822d-RN100
70
PORTMAP table size can only grow beyond 1024 characters after
using the "lscfg" CLI command repeatedly moving ports between
logical switches. The current PORTMAP table size can be calculated by
using CLI command "configupload -vf | grep PORTMAP" and count
the characters starting from "F" or "G" to the ending "]" character.
X6-8 or X6-4 director switches shipped from the factory with 8.2.0 or
higher FOS already installed will not be exposed to this issue unless
they were downgraded to a version of FOS prior to v8.2.0 and then
upgraded again to FOS 8.2.0 or later.
Workaround: Upgrading from a FOS version prior to v8.2.0 directly to FOS 8.2.2b or
later will avoid this issue. If the switch was previously upgraded to a
version of FOS 8.2.0 or higher prior to upgrading to FOS 8.2.2b, then
the upgrade to FOS 8.2.2b alone will not repair the PORTMAP table.
1. configupload -vf
Symptom: Historical graph values for TX/RX are all zeros. Real-time graph
values are accurately displayed.
Condition: When displaying historical graph values for TX/RX, the historical
display may show all zeros when monitoring on GEN 6 platforms.
Happens only when monitoring for historical graph values (Real-Time
graph values for TX/RX have no issue).
Issue is only seen when monitoring from BNA 14.4.4 or BNA 14.4.5.
Recovery: Rarely seen on GEN 5 platforms, but will recover on next historical
display request.
Condition: This occurs due to stale lisl ports in code being carried over from
FOS8.0.x FOS8.2.x
Broadcom FOS-822d-RN100
72
Reported In Release: FOS8.2.1 Technology: Fibre Channel
Services
Condition: Specific third party devices connected to ports that have area 0xff in
the Port Address.
Condition: When there is trunk and the trunk's Rx is divided by single port's
sample time instead of trunk's average sample time on all FOS8.x.
Broadcom FOS-822d-RN100
73
Symptom: Standby CP encountering Out Of Memory (OOM) reboot on task
esmd
Condition: Devices logging in and out of F-ports multiple times per second.
Condition: This is seen when system reset occurs with active IO in FX8-24 FCIP
configuration with FICON Emulation enabled for XRC traffic.
Symptom: Logical group used in rule can be deleted due to inconsistent handling
of letter case.
Condition: While deleting the map rule under active policy. Also while deleting
rules with -force option.
Workaround: Use proper group names or actual group names that are not
differentiated by case alone.
Broadcom FOS-822d-RN100
74
Symptom: When the Access Gateway switch has a single connection to the
director and porttrunkarea is set on the director, the Access Gateway
switch does not report the Switch F-port number.
Symptom: When changing templates and performing hafailover, the SSH config
is not replicated to the standby CP.
Condition: It happens after a cold boot or core blade slotpoweron. Routes for
ICL ports are incorrect such that fabric services on different switches
cannot communicate. This applies to FOS8.2.1 and above.
Symptom: Customer enabled framelog to capture unroutables , but not all frame
drops are captured in the framelog.
Broadcom FOS-822d-RN100
75
Condition: This issue is seen when the frame drop is less than 20 per second on
the port where the drop is being observed
Condition: This is seen with switch running FOS 8.x and above and is in AG mode.
Condition: It happens when multiple end devices connected to the same 16G
ASIC going through an error recovery which floods the ASIC with
PLOGI/ADISC.
Broadcom FOS-822d-RN100
76
Defect ID: FOS-812267
Condition: After FOS intentional powered down a blade due to PCI error by FOS
or a user issued slotpersistentpoweroff while running FOS8.1.0 or
earlier, a replacement blade cannot be powered up, or it's powered
down again after CP reboot.
Recovery: 1. Make sure a good blade is inserted , power on the blade via CLI
slotpoweron
2. Perform a hafailover,
Broadcom FOS-822d-RN100
77
Reported In Release: FOS8.2.1b Technology: Fibre Channel
Services
Condition: This is seen when FDMI attempts to deallocate the buffers used to get
the HBA/Port entries. The dynamically allocated block attempted to
be freed appear to be invalid due to possible corruption by memory
overrun.
Condition: MAPS had wrong port stats about congestion details leading to this
mapsdb show congestion/frequency inconsistencies.
Symptom: The ISL link between two G620 switches fails to recover and goes to
"HRD_FLT" state.
Broadcom FOS-822d-RN100
78
Defect ID: FOS-806463
Symptom: Following HAfailover some ports appear to encounter asic stats errors
which causes these ports to be fenced if MAPS is configured to fence
ports for ITW
Condition: The low level asic stats errors are not caused by the HA failover action
and appear to be from a prior uninitialized condition.
Condition: This occurs when the user is mapped to a custom role with RBAC class
of admin.
Broadcom FOS-822d-RN100
79
12.4 Closed with Code Changes in FOS 8.2.2a
Condition: 1. Move a port from default switch to logical switch, original PID in
the default switch still exists in the new logical switch. 2. Prohibit two
local ports by PDCM in FICON environment. routing is still allowed
between the two ports. This applies to FOS8.2.1 and later releases.
Workaround: Configure switch management port to Full Duplex mode. Half duplex
mode is not supported.
Broadcom FOS-822d-RN100
80
Defect ID: FOS-814782
Symptom: Lot of I/O failures and traffic disruption reported after performing
hafailover on Gen6 chassis-based switches.
Condition: Port blade and/or core blade slot power cycles, followed by
hafailover.
Recovery: Core blade power off and power on recover from this state.
Broadcom FOS-822d-RN100
81
Defect ID: FOS-811952
Symptom: Experience silent reboot (reboot reason: reset) or switch hung for
hours/days.
Condition: Running script with nested or concatenated CLI commands over 512
bytes long.
Workaround: Allow 5 seconds of idle time between commands and keep CLI length
under 512 bytes.
Symptom: CLI command portshow lan-stats --global -reset fails to reset "RX Error
IP Checksum" and "RX Error TCP Checksum" values back to zero.
Symptom: MAPS MISSING_SFP monitors on a Logical Switch (LS) but may not
action for their own LS and instead alert the violation on Default
Switch
Condition: This is seen when multiple logical switches are created and
MISSING_SFP monitoring is activated in DS and at least 1 LS.
Condition: When capturing FCIP debug information from a chassis with SX6 on
all FOS releases.
Broadcom FOS-822d-RN100
83
Defect ID: FOS-812572
Condition: This is encountered when customer runs porttest diag with a 3rd
party HBA connected to port.
Condition: This stems from a bug in the validation of the parameters when CLI
command configure --default is invoked.
Symptom: Seeing FICN-1056 Emulation Error 45 on the local side of the XRC
fabric while in EBR mode and running FICON XRC emulated traffic
through the tunnel.
Workaround: Enable port based or device based routing policy in the switches
Broadcom FOS-822d-RN100
84
Symptom: Encountered BLZ-5024 and DP reboot during FICON Channel Path
Recovery on a FICON Emulation enabled FCIP Extended CHPID.
Condition: This may occur during FICON Channel Path Recovery (Following
System Reset or Logical Path Removal) on a FICON Emulation
enabled FCIP Tunnel and there are device IOs outstanding at the
same time.
Symptom: User may observe Loss of Switch HA sync, along with the following
raslog message: [PDM-1010], , , WARNING,, File open failed:
/etc/fabos/certs/kafka/swKafkaca.pem, errno=2.
Condition: This occurs when the Switch is being monitored by SANnav before
performing a Hot Code Load (HCL) to FOS v8.2.1b on Gen6 platforms.
Symptom: The primary indicator for this defect is almost full utilization of WQE
buffers in switch DP complex. Secondary indicators for this issue
could be buffer allocation failure FTRACE triggers or a DP reset.
Condition: Buffer leaks can occur when IP extension connections are established
or rejected.
Broadcom FOS-822d-RN100
85
Reported In Release: FOS8.1.2f Technology: FCIP
Condition: This only occurs on a circuit created with ficon enabled. Any circuit
created without ficon, modified later to be ficon, or ficon circuit
changed to a different keepalive value and back to 1000 will not have
this display issue.
Condition: Internal software credits may leak when a LAN TCP connect attempt
is made before the extension tunnel is ready. Over time this may lead
to the tunnel no longer being able to pass traffic.
Symptom: Support new OUI 38:BA:B0 that will be used on future platforms.
Condition: This is a new development to add support for the new OUI.
Broadcom FOS-822d-RN100
86
Reported In Release: FOS8.0.1a Technology: FCIP
Symptom: IPEX enabled extension switch responds with RST to the incoming SYN
packet on the LAN side.
Condition: If the target tunnel is down, all the incoming SYN packets on the LAN
side will be dropped and responded back with RST for both
terminated and non-terminated TCP flows.
Condition: When customer attempts to use a 3rd party optics in a 10GbE port of
an extension switch or blade, the SFP goes into a Mod_Val state.
Symptom: An IPEX connected application may take a long time to timeout and
recover extended TCP flows after a local LAN connectivity outage.
Broadcom FOS-822d-RN100
87
Symptom: Dynamic D-Port test fails on a link between the switch and and the
HBA. Optical Loopback and Link traffic tests are not started.
Condition: The failure occurs due to a protocol error triggered by a timing issue
in initiating the ELP. It impacts FOS v8.x and later.
Symptom: Customer may encounter "a tape write errors has occurred" on OSTP
enabled tunnel on 7800, when appending to LTO8 tape drives.
Condition: OSTP Enabled tunnel on 7800, FX8-24 or 7840 (SX6 in later FOS levels)
when appending to an LTO8 tape. This issue does not occur with LTO5
tape drives.
Condition: This is seen on extended long distance 1G SFP with PN#: 00600-298
Symptom: configdownload CLI does not restore audit settings such as audit.cfg.*
parameters from the config file.
Broadcom FOS-822d-RN100
88
Defect ID: FOS-809770
Symptom: FICON Aborted sequences over FICON Emulation enabled FCIP Tunnel
after Extension HCL and potential FFDC due to FCIP DP Panic
Condition: Timing issue with aborts occurring and processing emulated XRC RRS
response sequences.
Condition: This is seen in webtools with brocade switches running FOS8.2.1 and
above.
Symptom: User may encounter cold reboot, along with mdd termination, during
MAPS rule creation with an invalid timebase.
Condition: This may occur during MAPS rule creation with an invalid timebase on
FOS versions v8.0.2x and lower. This release also enhanced code to
block invalid timebase configuration.
Broadcom FOS-822d-RN100
89
Reported In Release: FOS8.2.1 Technology: D-Port - Diagnostic
Port
Symptom: User may encounter CP reboot when running the CLI command
portdporttest --clear all
Condition: This may be encountered on Brocade 6520. Added EM-1228 and EM-
1229 raslog when power consumption exceeds 900W to help monitor
such condition.
Condition: This occurs when the config changes are initiated via WebTools
Broadcom FOS-822d-RN100
90
Defect ID: FOS-808732
Condition: This can happen during ISL route change, where traffic is paused.
Broadcom FOS-822d-RN100
91
Condition: Process deadlock after a certain order of devices coming online and
going offline and Name Server encountering a device entry Node
WWN as {00:00:00:00:00:00:00:00} from the Routed fabric (FCR)
Symptom: sfpshow displays supported speed as 16G instead of the full list of
4,8,16, 32 Gbps.
Condition: This is seen on X6-8 and X6-4 director switches with QSFP part
numbers 57-1000294-02
Condition: This occurs with REST Zone GET on empty effective Configuration
Broadcom FOS-822d-RN100
92
Defect ID: FOS-808171
Symptom: User may encounter asic error on core blade resulting in Disk errors
on the Servers/VMs.
Condition: This may be seen in the event that the core blade asic hardware goes
faulty. Monitor for threshold crossing detection and blade faults to
isolate the problem.
Symptom: Hafailover results in the port with port address zero being disabled.
Condition: FMS mode must be enabled in the logical switch. A base fabric must
be operational in the switch. The logical switch must have Allow XISL
enabled in the configure CLI command. One of the following
conditions would have needed to occur since the last hafailover: - A
chassisreboot or power cycle - Enabling Allow XISL in the configure
CLI command - Adding a new domain to the base fabric - Removing
and then re-adding an existing domain in the base fabric
Recovery: Enable the port with port address zero after hafailover
Broadcom FOS-822d-RN100
93
Defect ID: FOS-808077
Symptom: CLI switchcfgtrunk reports error message "Error: Unable to get port
configuration for port xx".
Condition: It's reported for every port of a vacant blade slot on X6 on FOS 8.2.x
and above.
Symptom: User may encounter the following error "/sbin/postinst: line 4199:
14000 Segmentation fault (core dumped) /bin/rcp
/mnt/fabos/cliexec/delduprule
root@$(otherhost):/fabos/cliexec/delduprule
Condition: This may occur on X6-8 when downgrading FOS, after all packages are
successfully downloaded to the standby CP secondary partition.
Symptom: User may encounter the following error message at telnet / log in
time switchName: fabosShowInit failed with -1 at line:144:root> With
no impact on FOS functionality.
Condition: This is seen if the user attempts to telnet / log into the system before
/ while it is still in the process of coming up and has not gone through
its config init yet.
Broadcom FOS-822d-RN100
94
Technical Severity: High Probability: Low
Symptom: Client switch accepts an invalid start-date sent from profile, when the
period is manually configured from CLI.
Broadcom FOS-822d-RN100
95
Symptom: When logging into console, "@" clears the login. This forces users to
SSH as user@domain or copy and paste the user id to console login.
Condition: This is generally a benign issue but may confuse and cause issues with
some MIB compilers.
Condition: Use "snmpconfig - set snmpv 3" command to set parameters, then
there are differences in the configuration files collected between
configupload and configdownload on following keys: -
snmp.snmpv3Keys.*.usmAuthKey - snmp.snmpv3Keys.*.usmPrivKey
Broadcom FOS-822d-RN100
96
Symptom: System run in a a prolong period of sub-optimal performance
condition before faulting the core blade
Condition: Suspect a hardware error condition caused stale asic after multiple
slow drain devices detected
Recovery: Power cycle the switch. This release added C4-1048/C3-1048 to help
user identify the condition as soon as possible to act on it.
Symptom: User sees the following error when executing the CLI command
portshow: porttrunkarea is configured for F-port trunks.'-i or -x'
option not supported.
Symptom: After using BNA to create rules, a new policy and activate the new
policy, switch cannot gain sync and needs cold boot to recover.
Condition: When a duplicate policy is created via BNA, CLI validates and rejects
duplicate rules.
Broadcom FOS-822d-RN100
97
Reported In Release: FOS8.2.1a Technology: MAPS - Monitoring
and Alerting Policy
Suite
Condition: This is seen only when Supportsave is invoked before diagpost has
completed.
Workaround: Invoke supportsave once diagpost has completed and system is fully
operational.
Symptom: Webtools doesn't report correct port stats and the 'Clear Counters'
button doesn't clear stats on all the ports.
Condition: When user clears port stats through Web Tool interface. CLI seems to
be ok.
Recovery: Since the issue leads to ports bouncing, no further recovery is needed
Broadcom FOS-822d-RN100
98
Defect ID: FOS-805522
Condition: This is seen when run with an alias name that has a possible HEX
value in it.
Condition: These messages are generally benign and may be seen during periods
of high CPU usage.
Symptom: Ras Log [C3-1021]"Encryption Compression Block error" and IFL link
will not come online when enabling ISL_RDY mode and Encryption on
IFL links
Condition: An Ex-Port to E-Port link (IFL) will flap continuously, when both
Encryption and ISL_RDY mode are enabled on the Ex-Port. The port
will not come online.
Workaround: Use either ISL RDY mode or Encryption on a Ex-Port, but not both on
the same port.
Broadcom FOS-822d-RN100
99
Defect ID: FOS-804616
Symptom: Software VERIFY error when WWN based Persistent PID is configured
Workaround: At least one WWN based Persistent PID entry could be bound to
avoid the VERIFY
Symptom: CLI command configdefault on a X6-8 and X6-4 chassis base switch,
that has encrypted links, pass without warning the user to remove
the encrypted links before the operation.
Workaround: Remove the encryption configuration from the FC32-48 port before
attempting the configdefault operation
Broadcom FOS-822d-RN100
100
Symptom: Observed ESM-1101 during a SX6 blade slotpower off with one of the
following: esm_cfg_sys.c:1586 esm_portcfg_clear() failed rc:176
esm_slot.c:1603 failed to release GE:10/ge2 rc:176 .
Symptom: portcmd --wtool stop-all error message isn't clear that its only
intended for Automated WAN Tool sessions.
Condition: When attempting to stop User WAN Tool sessions with portcmd --
wtool stop -all command
Workaround: Use "portcmd --wtool <wt-id> stop" command to stop User WAN Tool
sessions
Broadcom FOS-822d-RN100
101
Symptom: GE speed mismatch between 'switchshow' output and 'portcfgge --
show' output. Also unable to change port speed to 1G or issue
'portcfgdefault'. Configuration replay errors seen during switch
bootup and if the port is configured as a LAN 10G port, it may come
up as a WAN port after a reboot
Condition: On 7810, if GE port speed is set to 10G on any GE port and reboot is
performed after a time based license has expired
Recovery: Install a new valid license, which is not expired, and reboot the
switch. Alternatively the port can be recovered by disabling / enabling
autonegotiation using 'portcfgge <ge-port> --disable -autoneg'
followed by 'portcfgge <ge-port> --enable -autoneg'.
Workaround: Ensure that the peerzone is not empty after removing the alias. The
issue does not occur if member exist in the peer zone after alias
removal.
Broadcom FOS-822d-RN100
102
Workaround: Before firmware downgrade, system-description attribute can be
modified to display correct firmware version using "lldp --config -
sysdesc <string>" command.
Condition: In extremely rare cases, the CP panic may be seen due to a race
condition in the switch
Symptom: Removing the IP from a circuit that has SLA returns error for the
wtool and can leave the circuit in a out-of-sync state, which may
cause future modifications to fail.
Workaround: Remove the SLA from the circuit first, then remove the IP address.
Broadcom FOS-822d-RN100
103
Symptom: Switch has an over 2G size /var/log/wtmp file and cannot be
removed. It caused switch to run out flash space. The cron job
supposedly to truncate the large wtmp file is no longer running.
Workaround: Manually remove the over 2G size file and run "crontab
/fabos/sbin/mail_handler.sh" to re-active the cron job
Symptom: fcRouting configs such as fcRoute.Xlate and PersistXD configs are not
be restored to the Base FID of the X6-8 chassis using the config-file via
Brocade Network Advisor
Condition: The fcRouting entries of logical switch base FID 127 are not backed-up
by the BNA Configuration File utility
Workaround: Use BNA "configupload -all" type of function to upload Base switch
fcRouting entries
Broadcom FOS-822d-RN100
104
Reported In Release: FOS8.0.2 Technology: Trunking
Symptom: Duplicate PID observed on ports that were once part of F_Port trunks.
Condition: The area bound to F-port trunks can be lost if the F-port trunk is
disabled during hafailover.
Workaround: Make sure at least one F-port in each F-port trunk is online during
hafailover.
Symptom: During the config replay portion of hafailover / HCL indicating that an
error has occurred displays [ESM-1101], ERROR, esm_ha.c:8289
esm_ipaddr_add() failed (rc:25)
Workaround: Do not attempt to power cycle a blade during any kind of CP boot
operation. This includes removing and reinstalling the blade.
Recovery: An additional power cycle of the slot in question will recover the
configs.
Broadcom FOS-822d-RN100
105
Symptom: 100GE (25x4) QSFP in the FC32-64 blade does not report correct Tx
Power and leads to violations reported by MAPS
Symptom: Switch panic due to kernel trace module corruption. It also prevents
user daemon generate proper core file during daemon coredump.
Condition: It happens when a user daemon coredumps, and FFDC triggers to log
a trace.
Recovery: 1. Log in via console as root and execute "route add default gw
x.x.x.x" command to temporarily set the default gateway to the
correct address. This will temporarily allow for remote access to the
switch via IP address. 2. If the current IP address and subnet mask
need to be changed, use command "ifconfig eth0 x.x.x.x netmask
x.x.x.x" 3. Contact Technical support to clear the incorrect gateway in
WWN card 4. After the incorrect gateway address in WWN card is
fixed, then reboot the switch to bring back ipadm
Broadcom FOS-822d-RN100
106
Reported In Release: FOS8.1.1a Technology: Port Bring-up
Symptom: After connecting the adjacent ports within same switch, some ports
went to disabled, some ports shifted to G/E_ports frequently, while
some ports stayed in loopback as expected .
Condition: It happens on G610 with FEC enabled, on locked-16G using 32G SFP
and N16 using 16G SFP.
Workaround: When FEC is disabled, the issue does not occur and the ports became
loopback immediately.
Workaround: After deactivating the TI Zone, disable all E-ports that have the same
destination as the E-port with the DC-only route. Then enable them
all to clear the condition.
Recovery: Disable all E-ports that have the same destination as the E-port with
the DC-only route. Then enable them all to clear the condition.
Recovery: Try to bounce the port; This may not always work.
Broadcom FOS-822d-RN100
107
Defect ID: FOS-657728
Condition: This is a benign error seen only on upgrades to some versions that
lack checking for vf_enabled
Symptom: Switch may report false MAPS-1003/1004 alerts for SFP parameters
of voltage, temp, current, and receive power.
Broadcom FOS-822d-RN100
108
Reported In Release: FOS7.4.2e Technology: MAPS - Monitoring
and Alerting Policy
Suite
Condition: On F-ports which exhibit repeated slow drain behavior over a long
period (in terms of multiple days), MAPS Latency Impact RAS message
will report the amount of impact value > 100%.
Condition: This seen when IPv6 radius configuration is being added with peap-
mschapv2 protocol
Symptom: The standby CP firmware doesn't sync with the active CP firmware
version when CPs have different firmware versions.
Broadcom FOS-822d-RN100
109
Recovery: Issuing the firmwaresync manually will cause the firmware to be in
sync with the active CP.
Symptom: Software verify will be seen for each port that is attempted to be
moved between partitions.
Symptom: Failure to remove SIM port blocks attempt to remove expired flow
vision license.
Condition: This symptom is observed only when flow generator flow is active.
Broadcom FOS-822d-RN100
110
Condition: The message may be observed during non-disruptive
firmwaredownload operation on 7840.
Condition: The issue is observed when the port is running at almost full
bandwidth.
Recovery: Corrected values will be updated during the next portpershow display
cycle.
Condition: This is per design and the user is able to access the unit of the value
from monitoring-system-matrix container.
Broadcom FOS-822d-RN100
111
Condition: After running offline diag tests on G630, spinfab tests may fail or
frames may drop.
Workaround: Reboot the G630 after running offline Diag test (Plb, turboramtest ,
portledtest and systemverification ).
Symptom: Customer may experience that a port bounce results in loss of sync
Condition: This may be encountered on a switch with FMS mode enabled and
there is device performing PLOGIN with invalid SID.
Broadcom FOS-822d-RN100
112