Operation Instruction
Operation Instruction
INDEX
FUNCTIONS 1
FRONT PANEL 1
REAR PANEL 2
OPERATION GUIDANCE 2
PC SOFTWARE 4
SPECIFICATIONS 10
ACCESSORIES 10
DEVICE LINK 11
SAFETY INSTRUCTIONS 14
Digital System Controller
Functions
Front Panel
1 2 3 4 5 6 7 8
1
Digital System Controller
Rear Panel
1 2 3 4 5
1 Power Socket
The voltage is 95V - 250V
2 Power on / off Switch
3 Link in / out interface
CAT-5 cable ' s 1 PIN is RS485+
CAT-5 cable ' s 2 PIN is RS485-
4 Signal output interface
XLR balanced output 1-6
5 Signal input interface
XLR balanced input A-B
Operation Guidance
INPUT1 GAIN After entering edit status, input channel gain will be show first on LCD,the scale is
- 60 . 0dB -60dB--+12dB
Press RECALL key the first time enter PEQ paramenter setting status: PEQ number
PEQ : 1 F : 50 . 8 Q : 4 . 00
1-8 can be chosen,the scale of F is 20Hz-20kHz, Q is 0.4-128, G is -12dB--+12dB,
G : 0 . 0dB PEAK ON
filter style: PEAK,LOW-SHELF,HIGH-SHELF,bypass ON/OFF
GATE TH : - 70 . 0dB Press RECALL key the second time enter NOISE GATE setting status: the scale of
ATT : 30mS REL : 100mS THRESHOLD is -90dB--0dB, ATT is 1mS-200mS, REL is 1mS--999mS
Press RECALL key the third time enter DELAY parameter setting status: unit(mS),the
INPUT1 Delay
scale is 0-688mS; unit(m), the scale is 0-234m; unit(ft), the scale is 0-769ft.(press
0 . 000mS
SAVE key also can switch to edit ,but the sequence is opposite)
Press the first time, enter ID number setting: the ID number of the units should be
ID Number Select different when cascade connection, the setting scale is 1-254.(if cascade connection
ID : 1 units are over 16 or long distance, a loaded 120ohms resistance should be pararell
connected by Rs485
2
Digital System Controller
Operation Guidance
Unit Lock Press the second time, enter password setting: users can choose all the words or
Password [ 1234 ] numbers to set the password they want,the initial password is 1234
Input Source Select Press the second time, enter signal source selection: pink noise, white noise and sine
ANALOG INPUT wave 20Hz-20kHz
Copy Channel Select Press the fourth time ,enter copy channel selection: input or output channel
InA - > InB can copy freely
Store Preset Press save key ,enter preset save. Users can save the adjust status in U00-U31, and
U00 Default Preset F00 manufacture preset can not save
Load Preset Press RECALL key, enter preset transfer. Users can transfer the saved settings U00-
F00 Default Preset U31 and the initial setting F00
OUTPUT1 GAIN After entering edit, output channel gain will be show on LCD. The scale of gain is
- 60 . 00dB -60dB--+12dB
Press RECALL key the first time enter PEQ paramenter setting status: PEQ number
PEQ : 1 F : 61 . 1 Q : 4 . 00
G : 0 . 0dB PEAK ON
1-8 can be chosen,the scale of F is 20Hz-20kHz, Q is 0.4-128, G is -12dB--+12dB,
filter style: PEAK,LOW-SHELF,HIGH-SHELF,bypass ON/OFF
OUTPUT1 Delay Press RECALL key the second time enter DELAY parameter setting status: unit(mS),
0 . 000mS the scale is 0-688mS; unit(m), the scale is 0-234m; unit(ft), the scale is 0-769ft
Press RECALL key the third time, enter high pass and low pass parameter setting: the
HP : 19 . 7 BYPASS
LP : 20K16 BYPASS scale of high pass is 20Hz--20kHz, and low pass is 20Hz--20kHz. The style are
BUTTERWORTH, BESSEL, LINKWITZ, the slope is -6dB/oct-- -48dB/oct
INPUT MATRIX SELECT Press RECALL key the fourth time, enter matrix select setting, each channel can
INA : INB : choose one or several input channel signal
Press RECALL key the fifth time, enter compressor setting status: the threshold is
COMP TH : + 12dB
A : 30mS R : 100mS 1.0
-90dB-+12dB, attached time is 1mS--200mS, raleased time is 1mS--999mS, ratio is
(1:1,1:1.3,1:1.5---LIMIT)
OUTPUT1 POLARITY Press RECALL key the sixth time, enter phase adjust setting: the phase 0°or 180°can
0 be chosen. (press SAVE key also can switch to edit ,but the sequence is opposite)
3
Digital System Controller
PC software
Warning:the users ' manual , USB drive program and PC software are on the attached CD
Click the drive program“CDM 2 . 04 . 16 . exe”on the attached CD when offline . the below window
will show during the set up process
2 Click the PC software on the attached CD, press “next step” according to the default information, press
”finish” to exit till the PC software set up successfully,close the window after the below window shows:
4
Digital System Controller
3 connect the computer and the device with a USB cord,turn on the device,the computer will update the
new hardware automatically, during install the new hardware , the computer will tell you “find new
hardware”,“the hardware have already set up and can be used now”, you can find the current USB
COM number as the below steps:
1.move the mouse to “ computer” or” my computer” on the desktop, click “ management” by the right
mouse, show the below window:
2.After click “ device manager” ,continue to click“port(COM and LPT)”then popup the below window,
show the current USB COM number and then close the window:
5
Digital System Controller
4 If your computer system is Windows 7 or Windows 8,please operate according to the below steps;if
Windows XP or other systems, please skip this step, operate as “ step 5” directly
1.move the mouse to the PC software symbol (please do not open),choose “ properties” by the right
mouse, then popup the below window:
2.Below window will show by click “compatibility” , tick “Run this program as an administrator” which
below “Privilege level”, click “ apply” ,then “confirm”
6
Digital System Controller
5.Open PC software,the system will search USB COM automatically, the ttatus bar on the end of PC
software will turn red, and the LCD of the device will show “online”,it means the software and the
device connect successfully, you can operate the p r ocessor by the software now, click the online
symbol first when you exit, then close the software window:
7
Digital System Controller
8
Digital System Controller
PC software menu:
9
Digital System Controller
PC software
Accessories
10
Digital System Controller
The RS - 232 data of the computer can convert to RS-485 mode through AD485A , and it will be more
convenient for the device to long distance control.
RS - 485 can do long distance control and operation of several devices by center control system.
11
Digital System Controller
0 1 2 3 4 5 6 7 8
Packet 0x7B 0x7D 1~254 0x41~0x43 0x? ? 0x? ? 0x? ? 0x7D 0x7B
2 . Command Detail
0 1 2 3 4 5 6 7 8
( 2 ) Mute Control(0x42)
0 1 2 3 4 5 6 7 8
Packet 0x7B 0x7D 1~254 0x42 In : 0 Out : 1 0~3 No:0 Yes:1 0x7D 0x7B
0 1 2 3 4 5 6 7 8
12
Digital System Controller
0 1 2 3 4 5 6 7 8
MCU Return:0x00~0x90=-60dB~+12dB,0.5dB/Step
0 1 2 3 4 5 6 7 8
0 1 2 3 4 5 6 7 8
13
Digital System Controller
Satety Instruction
14
Digital System Controller
Satety Instruction
15