LQ Series High Voltage AC - DC Power Supplies XP Glassman Datasheet

The LQ Series are 10 kW, high voltage power supplies that can output voltages from 1 kV to 12 kV. They feature tight regulation, low ripple, and protection from overloads, arcs, and faults. The power supplies can operate from 200-480 VAC input and include redundant thermal protection, pulse-width modulation for efficiency, and arc quenching capability. They are rack mountable, CE compliant, and can be paralleled up to 50 kW total output.

Uploaded by

LeonardoMartin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views4 pages

LQ Series High Voltage AC - DC Power Supplies XP Glassman Datasheet

The LQ Series are 10 kW, high voltage power supplies that can output voltages from 1 kV to 12 kV. They feature tight regulation, low ripple, and protection from overloads, arcs, and faults. The power supplies can operate from 200-480 VAC input and include redundant thermal protection, pulse-width modulation for efficiency, and arc quenching capability. They are rack mountable, CE compliant, and can be paralleled up to 50 kW total output.

Uploaded by

LeonardoMartin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

LQ Series

10 kW Regulated
High Voltage DC
Power Supplies
1 kV to 12 kV
Rack Mount
CE Compliant
Parallelable To
50 kW Models from 0 to 1 kV through 0 to 12 kV, 8.75” H x 19” W x 24.0” D, 60 lbs.

200, 380, 415 & Features: Constant Voltage/Constant Current


480 VAC input Arc Quench. The HV output is inhibit-
Operation. Automatic crossover from
constant-voltage to constant-current
ed for a short period after each load arc
Options to help extinguish the arc.
regulation provides protection against
overloads, arcs, and short circuits.
Arc Count. Internal circuitry constantly Constant Current/Current Trip.
senses and integrates arcs that occur
Fully RoHS over a given time. In the event a system
A rear panel switch allows selection of
either current mode.
or load arcing problem develops and
Compliant exceeds factory-set parameters, the
power supply will cycle off in an attempt
Redundant Thermal Overload
Protection. Thermostats and fan RPM
to clear the fault and then automatically sensing shut down the power supply
The LQ family are sophisticated, 10 kW,
restart after a preset “off dwell time”. due to over temperature or reduced
high voltage power supplies with low
fan speeds.
ripple and noise. They are air insulated, Pulse-Width Modulation. Off-the-line
fast response units, with tight pulse-width modulation provides high Tight Regulation. Voltage regulation
regulation. efficiency and a reduced parts count for is better than 0.05% for allowable line
improved reliability. variations and 0.05% for allowable
Please refer to Technology > Applications load variations. Current regulation is
page on our web site for typical Low Ripple. Ripple is typically less better than 0.5% from short circuit
applications. than 0.1% RMS of rated voltage at full to rated voltage.
load.
The LQ Series are fully compliant with the
Warranty. All power supplies are
Air Insulated. The LQ Series features warranted for three years. A formal
following European Harmonized EMI “air” as the primary dielectric medium.
Directives: warranty statement is available.
No oil or encapsulation is used to
impede serviceability or increase
• EN61010/ IEC61010, Safety weight.
• EN61000-6-4, Conducted and Input Voltage. 208 VAC standard.
Radiated Emissions 380, 415 & 480 VAC optional.
• EN61000-6-2:2005, Conducted and
Parallelable. One master supply and
Radiated Immunity
up to 4 slave supplies for a maximum of
• 2011/65/EU, Restriction of the use 50 kW.
of Hazardous Substances (RoHS)
Specifications Protection: Automatic current regulation
protects against all overloads, including
Slave Front Panel Elements (20 - 50
kW Models): AC power on/off circuit
arcs and short circuits. Thermal switches breaker and indicator light, Bias, Tracking
(Specifications apply from 5% to 100% and rpm sensing fans protect against (Overvoltage), and thermal overload/low
rated voltage. Operation is guaranteed thermal overload. Circuit breaker, fuses, fan speed indicators and Slave voltage
down to zero voltage with a slight surge-limiting resistors, and low energy and current test points.
degradation of performance.) components provide ultimate protection. Remote Control Interface: All LQ family
Input: 187 - 228 V RMS, three-phase, Arc Quench. An arc quench feature power supplies provide a standard user's
48-63 Hz, 16.0 kVA maximum at full provides sensing of each load arc and remote interface.
load (less than 45 A/phase). Inrush quickly inhibits the HV output for
current is less than 150 A. A five The signals provided are:
approximately 20 ms after each arc.
position terminal strip is provided for Inputs: Safety interlock, output
AC line conection. Mains service Arc Count: Internal circuitry senses the voltage and current program
must be protected with fuses or number of arcs caused by external load signals, high voltage enable and
circuit breakers with a maximum discharges. If the rate of consecutive arcs connections for remote HV on and
rating of 125 A for 208 VAC models exceeds approximately one arc per off pushbuttons
& 100 A for 380 through 480 VAC second for five arcs, the supply will turn
off for approximately five seconds to Outputs: Output voltage and current
models. monitor signals, HV enable status,
allow clearance of the fault. After this
Efficiency: Typically greater than 85% period, the supply will return automati- I/V regulation mode status, fault
at full load. cally to the programmed output voltage status, and a +10 V reference source.
Output: Continuous, stable adjustment value with the voltage rise time constant Signal common and ground r
from 0 to rated voltage/current by means indicated. If the load fault still exists, the eference terminals are also provided.
of panel-mounted 10-turn potentiome- above cycle will be repeated. Optional Interfaces:
ters (0.05% resolution), or external 0 to Current Limit: In current limit mode RS-232/USB computer interface
+10 V signals. Repeatability better than the power supply will regulate the load (external add on assembly).
0.1% of setting. current at the programmed current level External Interlock: Open = off, closed =
Voltage programming accuracy: 1% of with automatic crossover between on. Normally latching except for "NC"
setting + 0.5% of rated output. voltage and current regulating modes. option supplies where it is non-latching.
Resolution is a function of the program- Current Trip: A switch located on the The interlock indicator LED is lit when
ming method used. rear of the control panel assembly allows the interlock is open.
Current programming accuracy: 1% of the selection of current limit or current HV Enable:
setting plus 1% of rated output. trip operation. When the switch is set to Remote Mode: 0 - 1.5 V = OFF,
Line Regulation: < +/- 0.05% of rated current trip mode, the HV output will 2.5 - 15 V = ON.
output for a +/-10% input line variation. disable and latch off when the load
current reaches the programmed current Local Mode: The HV output is
Load Regulation: < +/- 0.05% of rated permanently enabled.
output for a no load to full load change. level. Reset is accomplished by either
cycling the AC power, toggling the HV HV Status, Fault and I/V Regulation
Ripple: < 0.1% +1V RMS of rated output enable signal, or by pushing the HV Status: Each are a set of form "C" relay
voltage. off/reset and then the HV on switches. contacts.
Current Regulation: Better than 0.5% Front Panel Elements: The front panel Accessories: Detachable, 8 foot, shielded
from short circuit to rated voltage at any contains all local control functions and high voltage coaxial cable is provided.
load condition. indicators. These are: AC power on/off A 25 pin D-subminiature connector for
Voltage Monitor: 0 to +10 V equivalent circuit breaker and indicator light, customer interface is provided.
to 0 to rated voltage. Accuracy: 1% of separate 10-turn controls with locking Regulatory: The system will meet the
reading + 0.5% of rating. Output vernier dials used to set voltage and European conducted emission standards
impedance is 10 K Ohm. current levels, high voltage on switch, as specified in 2004/108/EC and the
Current Monitor: 0 to +10 V equivalent and high voltage off/reset switch. LED's European Low Voltage Directive,
to 0 to rated current. Accuracy: 1% of indicate: when high voltage is on, output 2006/95/EC.
setting plus 1% of rated output. Output polarity, interlock, fault status, and
Size: 8.75"H X 19"W X 24"D rack
impedance is 10 K ohm. whether the supply is operating in a
mounted chassis. Forced air cooling
voltage or current regulating mode.
Stability: 0.01% per hour after 1/2 hour is employed.
Output levels are indicated by voltage
warm-up, 0.05% per 8 hours.
and current digital meters.
Voltage Rise Time Constant: 50 ms
Rear Panel Elements: The rear panel
typical, using either HV enable or remote
contains the AC mains input connections
programming control.
with safety cover, AC power indicator, HV
Temperature Coefficient: 0.01%/° C. output, ¼-20 ground return stud, CL/CT
Ambient Temperature: -20 to +40° C, switch, 25 pin "D" interface connector,
operating; -40 to +85° C, storage. and a 12 position terminal strip. The
Polarity: Available with either positive or terminal strip provides local/remote
negative polarity. signal selection, interlock, and remote
HV ON/OFF functions.

www.xppower.com
Options
Symbol Description Symbol Description
200 180 to 220 VRMS, 3-phase input, 48-63 Hz, SS Slow start ramp. Specify standard times of 5, 10, 15, 20, or 30
derate output current by 10% seconds ± 20% .
380 342 to 440 VRMS, 3-phase input, 48-63 Hz ZR Zero start interlock. Voltage control, local or remote, must be at
415-50 370 to 460 VRMS, 3-phase input, 48-52 Hz zero before HV will enable.
480-60 430 to 530 VRMS, 3-phase input, 57-63 Hz K01 RS-232/USB control and monitor
5VC 0-5 V voltage and current program/monitor. K02 RS-232/USB/Ethernet control and monitor
NC Blank front panel, AC power breaker/switch
and indicator only, Please consult factory for special requirements.

Models

Outline For Models Greater Than 20 kW, Please Consult Factory.

www.xppower.com
Slave and System Outline