0% found this document useful (0 votes)
81 views

Procedure To Coldstart Via Service Setup WWC Tokheim Softw.

The document provides instructions for performing a cold start on a Tokheim WWCT1 software. It details 7 steps to switch off power, short a link, enter setup mode and country code, select pump configuration settings, and program the master pin code. It notes that prices must be programmed for each product before the pump can be used.

Uploaded by

Emmanuel Tsabola
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views

Procedure To Coldstart Via Service Setup WWC Tokheim Softw.

The document provides instructions for performing a cold start on a Tokheim WWCT1 software. It details 7 steps to switch off power, short a link, enter setup mode and country code, select pump configuration settings, and program the master pin code. It notes that prices must be programmed for each product before the pump can be used.

Uploaded by

Emmanuel Tsabola
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Cold Start Procedure

Procedure to a cold start on WWCT1


Tokheim software version
1) Switch off the power in the head
2) Short out link position W202
3) Whilst shorting W202 switch on the power and wait for the display to show

S e r v
S e t u p

4) Switch the power off, wait for the lights on the main board to go off and then
switch the power on again the display will show
S e t u p
P L n c d

5) Press on the remote control

6) The display will show

S e t u p
P L n c d
- - - -

7) Enter the setup pin code 1590

The will show display “Cntry Code”


Follow the programming procedure below

Press to change Select your country


C n t r y telephone code

the country code C O D E


0 0 0 0
Press to proceed

2
Used in Germany do not
S c A L E change
Press to proceed

n o
Liter or Gallon selection
G A L L o n Change to yes for Gallons
and the specify US or
Press to proceed Imperial Gallons
n o
Press to change Select 58 for a twin all
D I S P other model pumps are 50
S E t U P
Press to proceed 5 0
Press to change Select the number of hoses
H o S E for each side

Press for next digit L r


4 4
Press to proceed

Press to change Select the number of


d I S P L displays for each side

Press for next digit L r


1 1
Press to proceed

Special Application For


E S L E A Esso in Europe
Press to proceed U 0
t 0
Electromechanical Tote
E n n t application dual or single
Press to proceed operation

3
Master pin code
n n A S T
Press to proceed P L n c d

Press to change Master Pin code- If “0000”


E n t E r then not active any other
P L n c d number and it becomes a
security code to enter
Press to proceed - - - - programming functions

Press to change Repeat the number entered


v E r I F y in the previous function
P L n c d
Press to proceed - - - -
Invert the nozzle switches
I n P U t activation from normally
Press to proceed t y p e open to normally close.
Used on non address bus
n o models
After a couple of seconds
Display return to last sale 0 0 0
0 0 0
0 0 0 0

Note: A price needs to be programmed for each product before the pump can be
used. All other required default values must be changed as required. For instance
setting pump address and console/standalone operation etc.