Bandwidth Limit 20MHz 20M/100MHz 20M/100M/200MHz Vertical Sensitivity 8 bit Resolution 1mV~10V/div Input Coupling AC, DC, GND Input Impedance 1MΩ// 16pF approx. ±(3%)when 2mV/div or greater is selected DC Gain Accuracy ±(5%)when 1mV/div is selected; Polarity Normal & Invert Maximum Input 300Vrms, CAT I Voltage 1mV/div ~ 20mV/div : ±0.5V Offset Position 50mV/div ~ 200mV/div : ±5V Range 500mV/div ~ 2V/div : ±25V 5V~10V/div : ±250V Waveform Signal +, -, ×, ÷, FFT, User Defined Expression. Process FFT: 1Mpts FFT: Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman. Trigger Source CH1 ,CH2 Line, EXT Trigger Mode Auto (supports Roll Mode for 100ms/div or slower), Normal, Single Sequence Edge, Pulse Width(Glitch), Video, Pulse Runt, Rise & Fall(Slope), Alternate, Time Trigger Type out, Event-Delay(1~65535 events), Time-Delay(Duration,4nS~10S), Bus Holdoff range 4ns~10s Coupling AC, DC, LF rej., HF rej. , Noise rej. Sensitivity 1div External Trigger Range ±15V DC ~ 100MHz Approx.100mV Sensitivity 100MHz ~ 200MHz Approx. 150mV 200MHz ~ 300MHz Approx. 150mV Input Impedance 1MΩ±3%~16pF Horizontal 1ns/div ~ 100s/div (1-2-5 increments) Time base Range ROLL: 100ms/div ~ 100s/div Pre-trigger 10 div maximum Post-trigger 2,000,000 div maximum. Time base Accuracy ±50 ppm over any ≥ 1ms time interval Real Time Sample Max.:2GSa/s Rate Record Length Per Channel 20M pts Acquisition Mode Normal, Average, Peak Detect, Single Peak Detection 2ns (typical) Average selectable from 2 to 256 X-Y Mode X-Axis Input Channel 1 Y-Axis Input Channel 2 Phase Shift ±3° at 100kHz Cursors and Measurement Cursors Amplitude, Time, Gating available unit: Seconds(s), Hz(1/s) ,Phase(degree) ,Ration(%) 38 sets: Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Automatic Area, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Frequency, Period, RiseTime, FallTime, Measurement +Width, -Width, Duty Cycle, +Pulses, -Pulses, +Edges, -Edges, %Flicker ,Flicker Idx,FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF, Phase Control Panel Function Auto counter 6 digits, range from 2Hz minimum to the rated bandwidth Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with Autoset undo Autoset Save Setup 20 sets Save Waveform 24 sets Display TFT LCD Type 8" TFT LCD WVGA color display Display Resolution 800 horizontal × 480 vertical pixels (WVGA) Interpolation Sin(x)/x Waveform Display Dots, vectors, variable persistence (16ms~4s), infinite persistence Waveform Update 120,000 waveforms per second, maximum Rate Display Graticule 8 x 10 divisions Display mode YT ;XY Interface USB Port USB 2.0 High-speed host port X1, USB 2.0 High-speed device port X1 Ethernet(LAN) Port RJ-45 connector, 10/100Mbps with HP Auto-MDIX Go-NoGo BNC 5V Max/10mA TTL open collector output Kensington Style Rear-panel security slot connects to standard Kensington-style lock. Lock Spectrum Analyzer Specifications Frequency range DC~1GHz (Max. ,Max.bandwidth~1GHz uncalibrated) Span 1kHz~1GHz(Max.)
Resolution 1Hz ~ 1MHz(Max.)
bandwidth Reference level -50 dBm to +40dBm in steps of 5dBm Vertical units dBV RMS; Linear RMS; dBm Vertical position -12divs to +12divs Vertical scale 1dB/div to 20dB/div in a 1-2-5 Sequence Display average 1V/div < -50dBm, Avg : 16 noise level 100mV/div < -70dBm, Avg : 16 10mV/div < -90dBm, Avg : 16 Spurious response 2nd harmonic distortion< 40dBc 3rd harmonic distortion< 45dBc Frequency domain Normal ; Max Hold ; Min Hold ; Average (2 ~ 256) trace types Detection methods Sample ; +Peak ; -Peak ; Average FFT Windows FFT Factor : Hanning 1.44 Rectangular 0.89 Hamming 1.30 Blackman 1.68 AWG Specifications (On MDO-2000AG only) Channels 2 Sample Rate 200 Msa/s Vertical Resolution 14 bits Max. Frequency 25 MHz Waveforms Sine, Square, Pulse, Ramp, DC, Noise, Sinc, Gaussian, Lorentz, Exponential Rise, Exponential Fall, Haversine, Cardiac Output Range 20 mVpp to 5 Vpp, HighZ;10 mVpp to 2.5 Vpp, 50 Ω Output Resolution 1mV Output Accuracy 2% (1 kHz) Offset Range ±2.5 V, HighZ;±1.25 V, 50 Ω
Offset Resolution 1mV
Sine Frequency Range 100mHz to 25MHz Flatness ±0.5 dB Harmonic -40 dBc Distortion Stray -40 dBc (Non-harmonic) Total Harmonic 1% Distortion S/N Ratio 40 dB Square/Pulse Frequency Range 100 mHz to 15MHz Rise/Fall time <15ns Overshoot <3% Duty cycle Square:50%;Pulse:0.4%~99.6% Min. Pulse Width 30 ns Jitter 500 ps Ramp Frequency Range 100mHz~1MHz Linearity 1% Symmetry 0 to 100% Frequency Response Analysis (MDO-2000AG only) Dynamic Range > 80 dB (typical) Input and Output Channel 1 or 2 Sources Frequency Range 20 Hz to 25 MHz Number of Test 10 to 90 points per decade Points
Test Amplitude 20 mVpp to 5 Vpp into High-Z ;Fixed test amplitude or custom amplitude for each decade
Test Results Logarithmic overlaid gain and phase plot
Manual Two pairs of tracking gain and phase markers Measurements Plot Scaling Auto-scaled during test Miscellaneous Multi-language Available menu operation Temperature: 0°C to 50°C. Relative Humidity ≤ 80% at 40°C or below; ≤ 45% at 41°C ~ 50°C environment On-line help Available Time clock Time and Date ,Provide the Date/Time for saved data Dimensions 384mmX208mmX127.3mm Weight 3kg