This document provides instructions for configuring an elevator controller using a Honeywell PRO3200 panel with a PRO32OUT output module. The steps include: 1. Opening the device map and selecting the PRO32 panel to configure it. 2. Creating triggers and procedures to control the elevator groups and outputs. 3. Setting up output groups on the procedures to represent each floor. 4. Configuring triggers to activate the correct output group based on the user's card info. 5. Assigning card user levels that match the trigger settings.

Uploaded by

Luis Silva
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views

Pro3200 How To Program An Elevator Controller With Pro32OUT RevB

This document provides instructions for configuring an elevator controller using a Honeywell PRO3200 panel with a PRO32OUT output module. The steps include: 1. Opening the device map and selecting the PRO32 panel to configure it. 2. Creating triggers and procedures to control the elevator groups and outputs. 3. Setting up output groups on the procedures to represent each floor. 4. Configuring triggers to activate the correct output group based on the user's card info. 5. Assigning card user levels that match the trigger settings.

Uploaded by

Luis Silva
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

PRO3200

How to Configure an elevator controller using PRO3200 with PRO32OUT?

Question

How configure an elevator controller using PRO3200 with PRO32OUT

Answer

1. Open Device Map, select the panel PRO32 and select the option for Configure

2. This panel works with Triggers & Procedures


3. On Triggers & Procedures can create the groups to work with the elevator.

This document contains Honeywell proprietary information. Information contained herein is to be used solely for the purpose submitted, and no part of this document
or its contents shall be reproduced, published, or disclosed to a third party without the express permission of Honeywell International. HONEYWELL DISCLAIMS THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PURPOSE AND MAKES NO EXPRESS WARRANTIES EXCEPT AS MAY BE STATED IN ITS WRITTEN
AGREEMENT WITH AND FOR ITS CUSTOMER. In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information and
specification in this document are subject to change without notice.
Company Internal

Discover | Customer Portal June 21, 2019 YouTube | Help & Support
PRO3200
4. Create the Group of Outputs on Procedures

5. Each element on Action List represent an Output and each Output represent a Floor
6. The configuration for each Output is as follows

• On the Procedure we need to set the Name.


• For Action Target > Do output action.
• For Output SIO > the PRO32OUT.
• Output Device > The Output we have assign for the floor.
• Output Action > Pulse > and set the TIME for the Pulse.

7. The same process need to be done on each floor.


8. The way to activate the Output Groups on the Procedures is with the Triggers and they need to be as follows

• On the Triggers we need to set Name.


• Select the procedure created before.
• For Trigger Source select Reader.
• For Source SIO the PRO32R2 where is the elevator located.
• For Trigger Source select the Reader needed to call the elevator.
• Transaction Type > Formatted Card: Number Only.
• Time Zone > Always ON.
• For Trigger Transactions leave all by default and for Card User Level to
Trigger ON > Set the number of the Trigger depend of the procedure to
work with.

a. Example > Trigger 1 working with Procedure 1 have the Card User Level 1
9. Configure the cards to work with the Card User Level to Trigger
a. On the Menu for Card > select Cards… either edit the card or create a new one, need to assign the Card
User Level to Trigger depend on the floor access the card holder need
This document contains Honeywell proprietary information. Information contained herein is to be used solely for the purpose submitted, and no part of this document
or its contents shall be reproduced, published, or disclosed to a third party without the express permission of Honeywell International. HONEYWELL DISCLAIMS THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PURPOSE AND MAKES NO EXPRESS WARRANTIES EXCEPT AS MAY BE STATED IN ITS WRITTEN
AGREEMENT WITH AND FOR ITS CUSTOMER. In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information and
specification in this document are subject to change without notice.
Company Internal

Discover | Customer Portal June 21, 2019 YouTube | Help & Support
PRO3200

The cards need to be assigned the P. Series Trigger


Note: Control with the same number that is on Card User Level to
Trigger on the Trigger to work with the procedure.

10. Once all the P. Series Trigger Control numbers has been assigned only save and initialize the panel to take all the
changes and the elevator controller start working.

This document contains Honeywell proprietary information. Information contained herein is to be used solely for the purpose submitted, and no part of this document
or its contents shall be reproduced, published, or disclosed to a third party without the express permission of Honeywell International. HONEYWELL DISCLAIMS THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PURPOSE AND MAKES NO EXPRESS WARRANTIES EXCEPT AS MAY BE STATED IN ITS WRITTEN
AGREEMENT WITH AND FOR ITS CUSTOMER. In no event is Honeywell liable to anyone for any direct, special, or consequential damages. The information and
specification in this document are subject to change without notice.
Company Internal

Discover | Customer Portal June 21, 2019 YouTube | Help & Support

You might also like