This document provides a user guide for the OCS-T high resolution digital crane scale. It includes sections on safety guidelines, features, specifications, dimensions, display and keys, operations such as powering on/off, zeroing, taring, and user setup options for auto-off timing and display brightness. The guide describes the scale's capacities between 1,000-5,000kg, LED display, rechargeable battery, and operating temperature range between -10-40°C. It also outlines error messages, loading procedures, and troubleshooting tips.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
56 views

Manual - OCS-T - V1 ENG

This document provides a user guide for the OCS-T high resolution digital crane scale. It includes sections on safety guidelines, features, specifications, dimensions, display and keys, operations such as powering on/off, zeroing, taring, and user setup options for auto-off timing and display brightness. The guide describes the scale's capacities between 1,000-5,000kg, LED display, rechargeable battery, and operating temperature range between -10-40°C. It also outlines error messages, loading procedures, and troubleshooting tips.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

OCS-T

High Resolution Digital Crane Scale

User Guide

Manual_OCS-T_V1
Content
1. Safety Guide ............................................................................. 1
2. Features ..................................................................................... 1
3. Specifications ............................................................................ 2
4. Capacity .................................................................................... 3
5. Dimension & Weight ................................................................ 3
6. Display & Keys ......................................................................... 4
Scale Keys .............................................................................4
Remote Keys .........................................................................4
Indicators ..............................................................................5
Message ................................................................................5
7. Operations ................................................................................. 6
Power On/Off ........................................................................6
Zero .......................................................................................6
Tare In/Out ............................................................................6
Lock/unlock ..........................................................................7
Accumulate ...........................................................................7
View ......................................................................................7
Delete Last Weight ................................................................7
Clear All Weight ....................................................................8
Unit Switch ...........................................................................8
8. User Setup................................................................................. 8
Auto-Off Timing ...................................................................8
Display Brightness ................................................................9
Idle Mode Timing..................................................................9
9. Battery Maintenance ................................................................. 9
10. Troubleshooting .................................................................... 10
11. Loading Procedures .............................................................. 12

Please read this manual carefully before using. Version: V1.0A-3


High Resolution Digital Crane Scale

1. Safety Guide
For good performance and precise measurement, be careful
with daily operation and maintenance.

 Do NOT overload scale. This will damage loadcell and void


warranty.
 Do NOT leave load hung on the scale for long. This will
decrease scale’s accuracy and shorten loadcell’s life.
 Inspect shackle and hook before using. Check clips, pins and
screws regularly.
 Check battery frequently. When scale runs out of power, charge
battery with its dedicated charger.
 Rotate load rather than scale if needed.
 Do NOT use scale under thunder or rain.
 Hang scale on shelf in dry and well-ventilated room. Do NOT
place scale on the ground directly.
 Do NOT attempt to repair scale yourself. Contact your local
representative.

2. Features
This scale is a combination of sound and proven mechanical
design, with today’s most advanced electronics to provide a superb
feature set. It is versatile, reliable, accurate and easy to operate.

 Superb Quality. Strictly in accordance with OIML R76, Chinese


GB/T11883-2002 national standards, and European CE
directives.
 Great Safety. Aluminum-casting case, high firm hook and

Page 1 of 12
High Resolution Digital Crane Scale
shackle, dedicated weighing loadcell for safety installation.
 Strong Reliability. Cutting-edge technology, quality integrated
circuit for high performance and long time stability.
 Broad Applicability. Popular and applicable in storage, textile,
metallurgy industry, and so forth.
 Easy to Use. Ultra-red remote controlling design. Easy to
operate on the scale or in distance.
 Complete Function. Resolution switch, unit conversion, auto
power-off, battery inspection, etc.

3. Specifications
Chinese GB/T 11883-2002 Class III
Accuracy Class
Equivalent to OIML R76
Tare Range 100% F.S.
Zero Range 4% F.S.
Stable Time ≤10sec
Overload 100% F.S. + 9e
Safety Load 150% F.S.
Ultimate Load 400% F.S.
Battery 6V/4.0Ah lead acid rechargeable battery.
100~220VAC 50/60Hz input
Charger
7.2VDC/1000mA output
Display 35mm (1.4inch) LED module
Op. Temp. -10℃ ~ +40℃
Op. Humidity 20℃ ≤90%

Page 2 of 12
High Resolution Digital Crane Scale

4. Capacity
Modal Max. Cap. Min. Cap. Res. Division
OCS-1-T 1,000kg 10kg 0.5kg 2,000
OCS-2-T 2,000kg 20kg 1kg 2,000
OCS-3-T 3,000kg 20kg 1kg 3,000
OCS-5-T 5,000kg 40kg 2kg 2,500

5. Dimension & Weight


255
A 210
B
L

Page 3 of 12
High Resolution Digital Crane Scale
Modal A B C L N.W.
OCS-1-T 68mm 112mm 40mm 420mm 11.0kg
OCS-2-T 68mm 112mm 40mm 420mm 11.0kg
OCS-3-T 68mm 112mm 40mm 420mm 11.0kg
OCS-5-T 68mm 112mm 45mm 450mm 12.5kg

6. Display & Keys


Scale Keys
Key Name Function
Press 1s to power on/off scale.
On/Off
Return to weighing mode.
Manual Zero.
Zero
Increase flashing digit.
Tare in/out.
Tare
Right scroll flashing digit.
Lock/unlock reading.
Hold
Confirm.

Remote Keys
Key Name Function
Zero Same as .

Tare Same as .

Hold Same as .
Accumulate weight.
Acc.
Decrease flashing digit.

Page 4 of 12
High Resolution Digital Crane Scale
Delete last weight.
Del. Clear all weight.
Left scroll flashing digit.
View.
F1
Input decimal point.
F2 Unit switch.
Press 1s to power off.
Off
Return to weighing mode.
2nd 2nd function.

Indicators
LED Name Note
STB. Stable lit when weight is stable
ZERO Zero lit when weight is at zero
TARE Tared lit when scale is tared
HOLD Hold lit when scale is locked
lb lb lit when unit is lb
kg kg lit when unit is kg

Message
Message Stand for Note
----- detect weight
||||? in Idle Mode
Setup SETUP User Setup Menu
Bat?? BATtery battery life percentage
P0000 Password in Password Mode
|end| END save and exit
|off| OFF power off

Page 5 of 12
High Resolution Digital Crane Scale

|over OVERload overloading


|2nd| 2ND 2nd function
|err| ERRor invalid operation
|acc| ACCumulate accumulate weight
|del| DELete delete last weight
|Clr| CLeaR delete all weight

7. Operations
Power On/Off
 Press for 1s to power-on scale. Scale perform initialization
and power-on test, ***** shows twice, then capacity |5000
shows, battery life percentage bat90 shows, weight detection --
--- shows and then auto zero.
 For information about Auto-Zero, refer to Scale Configuration in
Technical Manual.
 Press or for 1s to power-off scale. Battery life percentage
bat90 shows, off message |off| shows, and then cut off power.
Zero
 Press or to zero. ZERO light on.
 If load is in motion, or tared, or out of Manual-Zero Range, |err|
shows.
 For information about Manual-Zero Range, refer to Scale
Configuration in Technical Manual.

Tare In/Out
 In gross mode, press or to tare in. TARE light on.
 If load is in motion, or negative, or out of Tare Range, |err|

Page 6 of 12
High Resolution Digital Crane Scale
shows.
 Tare will reduce the apparent overload range of scale. For
example, if a 5000*2kg scale has a 1000kg container as its tare,
the scale will overload at a new weight of 4018kg (5000 – 1000 +
additional 9 divisions).
 In net mode, press or to tare out. TARE light off.

Lock/unlock
 Press or to lock screen. HOLD light on.
 Press or to unlock screen. HOLD light off.

Accumulate
 Press to accumulate current weight.
 |acc| shows, indicating weight is accumulated. Scale uses
displayed weight, so gross or net weight is added into the same
accumulator.
 If load is in motion, or negative, or does not return to zero
before, |err| shows.

View
 Press to enter View mode.
 Display flashes accumulated weight.
 Press or to view high 5-digit or low 5-digit.
 Press or to exit View mode.

Delete Last Weight


 Press to delete last accumulated weight.
 |del| shows, indicating last accumulated weight is deleted.
Delete function only deletes the last weight.
 If last accumulated weight has been deleted, |err| shows.

Page 7 of 12
High Resolution Digital Crane Scale

Clear All Weight


 Press first and then press to clear all accumulated
weight.
 |clr| shows, indicating all weight is cleared.
Unit Switch
 Press to switch unit in between kg, lb, and User Unit.
 When unit is kg, kg LED light on. When unit is lb, lb LED light
on. When unit is User unit, kg and lb LED all light off.
 For more information about User Unit, refer to Scale
Configuration in Technical Manual.

8. User Setup
 Press first and then press or to enter User Setup
menu. setup shows.

Auto-Off Timing
 Press or to enter Auto-Off Timing. off?? shows.
 Press or and to change timing value.
 Auto-Off Timing can be set to: 0(disabled), 5(5min), 10(10min),
15(15min), 30(30min), 60(60min). It is disabled by default.
 Auto-Off function maximizes scale’s battery life against people’s
carelessness not to power off scale when it’s not working. Auto-
Off starts countdown timer when there’s no action or load is
stable. Any key pressing or motion in load restarts countdown
timer.

Page 8 of 12
High Resolution Digital Crane Scale

Display Brightness
 Press or to enter Display Brightness. br||? shows.
 Press or and to change brightness value.
 Display Brightness can be set to:1(dim), 2(normal), 3(bright).
 Dim LED brightness saves battery power dramatically.

Idle Mode Timing


 Press or to enter Idle Mode Timing. idl?? shows.
 Press or and to change timing value.
 Idle Mode Timing can be set to: 0(disabled), 5(5sec), 10(10sec),
15(15sec), 30(30sec), 60 (60sec). It is 30sec by default.
 To maximize battery life, scale automatically enters Idle Mode,
when there’s no action or the load is stable. In Idle Mode, scale
works in low-power consumption status. Any key pressing or
motion in load wakes up scale from Idle Mode.
 Press or to exit User Setup.

9. Battery Maintenance
To maximize battery life, please note the following battery
maintenance guide.

 This scale is powered by a 6V4.0Ah rechargeable lead-acid


battery.
 Battery is permanently fixed inside battery house.
 Depending on LED brightness and idle mode setting, battery
works from 60 hours to 200 hours.
 In order to conserve battery life, enable Auto-Off and Idle Mode,
dim LED brightness.
 Charging time for a completely discharged battery is

Page 9 of 12
High Resolution Digital Crane Scale
approximately 12 hours.
 To obtain maximum service life, battery should be stored
between -20℃ (-4°F) and +50℃ (122°F). Stored batteries should
be recharged every three months.
 During charging, green LED indicates full of power, while red
indicates that charging is going on.

10. Troubleshooting
Simple problems can be resolved as below listed solution. If
problems still exist, please contact your local representative.

Symptom Possible Cause Suggested Solution


discharged / check battery and
defective battery charge
defective On/Off press harder and keep
not power-on
key pressing 2s
after On/Off
defective power open front panel,
is pressed
cable check power cable
defective
contact representative
mainboard
display
discharged battery charge battery
flashes
no action scale is disturbed re-plug power cable
taken after
defective key contact representative
key pressed
load in motion keep load stable
weight
change Anti-Motion
reading not weak Anti-Motion
level
stable
damped loadcell or dry loadcell or

Page 10 of 12
High Resolution Digital Crane Scale
mainboard mainboard
defective
contact representative
mainboard
weight discharged battery charge battery
reading not load-cell stressed
hang scale in storage
zero when too long
no load discharged battery charge battery
scale not zeroed
manual Zero scale
before applying
before loading
load
large error in
wrong unit switch to correct unit
weight
scale requires
reading calibrate scale
calibration
defective loadcell or
contact representative
mainboard
battery can defective charge
contact representative
not be board
recharged defective battery contact representative
short remote discharged /
replace remote
controlling defective remote
controller batteries
distance battery

Page 11 of 12
High Resolution Digital Crane Scale

11. Loading Procedures


DO NOT attach oversized DO NOT push/pull on loaded
interface! scale or directly on hook!

× ×
DO NOT use multiple Use hardware that creates single
attachments! point attachments.

× √

Page 12 of 12
USER MANUAL

Box 79 Industrivägen 3 Tel. +46 (0)176-208920 Web www.vetek.com


76040 Väddö, Sverige Fax +46 (0)176-208929 Email [email protected]
1

You might also like