0% found this document useful (0 votes)
102 views3 pages

Medicion de Suciedad NRG - 35W - Soiling - TPS - WEB

This document provides specifications for NRG's 35W Soiling Measurement Kit, which measures the impact of soiling on PV panels. It consists of a pair of 35W PV modules, temperature sensors, and an interface module. The interface module measures the current from each panel to calculate a soiling ratio. The document describes installing the kit, including mounting the panels, running wiring, and programming a data logger to measure and record the current, temperature, and soiling ratio over time.

Uploaded by

DOUSAN ALEU
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
102 views3 pages

Medicion de Suciedad NRG - 35W - Soiling - TPS - WEB

This document provides specifications for NRG's 35W Soiling Measurement Kit, which measures the impact of soiling on PV panels. It consists of a pair of 35W PV modules, temperature sensors, and an interface module. The interface module measures the current from each panel to calculate a soiling ratio. The document describes installing the kit, including mounting the panels, running wiring, and programming a data logger to measure and record the current, temperature, and soiling ratio over time.

Uploaded by

DOUSAN ALEU
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

35W SOILING MEASUREMENT KIT

TECHNICAL PRODUCT SHEET

Overview
NRG’s Soiling Measurement Kit provides users with the
information needed to quantify the site-specific impacts
of soiling caused by dust, snow, and other particles on
prospective as well as operating PV projects.

Specifications
Sensor Type Soiling Measurement Kit | 35 W, consisting of:

• Matched pair of 35 W monocrystalline


PV modules

• (2) NRG PVT1 PV Temperature Sensors

Measurement Range • Soiling interface module Isc: 0 A to 15 A

• PV temperature: -40 C to +105 C


Output Signal Type · Isc: Analog voltage

· PV temperature: 10 kΩ NTC thermistor


Accuracy • Isc: ± 0.05 A from -40 °C to +85 °C

• PV temperature: ± 0.2 °C from 0 °C to 70 °C


Tools Required
• Ratchet with 7/16”, 1/2”, and 9/16” Sockets Supply Voltage
Soiling interface module: 5 VDC to 28 VDC
• 1/2” Crow’s Foot
• Torque Wrench with min. range of 5-30 ft-lbs Supply Current
Soiling interface module: 2.5 mA maximum
• Tape Measure, Angle Finder,
and Torpedo Level Operating Temp Range • Soiling Interface Module: -40 °C to +85 °C
• 3mm Slotted Screwdriver
• PV temperature sensor: -40 °C to +105 °C
35W Soiling Measurement Kit Installation Process
1. Install the Solar Pipe Boom by following the Solar_PipeBoom_Instructions.pdf.
2. D
 etermine the orientation of the two 35W panels and install the PV Mounting Brackets to the panel frames using
1/4-20 carriage bolts & serrated flange locknuts. Torque to 8 ft-lbs.
NOTE: T
 he two panels should be installed in the same orientation. Landscape is preferred but may not be possible
depending on the configuration of the tower. When installing panels in portrait orientation, the U-bolt mounting
holes should be located outside the panel frame.
3. L
 oosely install U-bolts onto the PV Mounting Plates.
4. S
 lide the panels onto the Solar Pipe Boom and arrange them side by side. Tighten the U-bolts loosely so the panels stay in
place but can be moved.
5. Use an angle finder to set the panels at the desired angle and tighten the U-bolts securely (13 ft-lbs/17.6 Nm)
6. Install the “Clean” and “Dirty” labels to the edge of the 35W PV panels.
7. Run the PV wires and PVT1 PV Temperature Sensor wires to the logger shelter box.
8. Install the Soiling Interface Module into the shelter box and wire the PV wires into the Clean and Soiled (dirty)
terminals. Wire the 4C cable from the interface module to the logger wiring panel.
9. Wire the PVT1 PV Temperature Sensors into the logger wiring panel.
10. Program the SymphoniePRO Data Logger: See next page

2-4

6 CLEAN DIRTY

7
9 SymphoniePRO Logger Programming
Use the SymphoniePRO Desktop Application to program the sensor
settings into the data logger:

ISC MEASUREMENT
(example on channel 18)
1. Enable Channel
2. Enter “Isc Clean” in the Description
3. Enter the height of the module
4. Enter Scale Factor: 3.125
5. Offset: 0
6. Units: Amps
7. If installed on Ch. 16-19, set Excitation settings:
• Mode: Constant On
• Voltage: 12 V
8. If installed on Ch. 20-26, use P-SCM #9132
9. Repeat this process on channel 19, but with a description of “Isc Dirty”

BACK OF MODULE TEMPERATURE


(example on channel 20)
1. Choose “NRG PVT1 PV Temperature Sensor” from the Defaults
drop down menu
2. E dit the Description to “PV Temp Clean”
3. Enter the PVT1 sensor serial number
4. Enter the height of the sensor
5. R epeat this process on channel 21, but with a description of
“BoM PV Temp Dirty”

SOILING RATIO
(example on channel 100)
1. Choose Calculation Type “Ratio”
2. Edit the Description to “Soiling Ratio”
3. Enter the Units as “Ratio”
4. Numerator Source: choose the “Isc Dirty” channel
5. Denominator Source: choose the “Isc Clean” channel

For more information:


NRG Technical Support
+1 802.482.2255
[email protected]
nrgsystems.com
ISO 9001: 2015 Certified
12_2021_V2

ISO 14001: 2015 Self-Certified

You might also like