General Notes
General Notes
Email: [email protected]
General
Notes
Software
Job Description
Owner
Consultant
اﺷﺮاف ﻋﻠﻰ اﻟﺘﻨﻔﯿﺬ
ﻋﻤﻞ اﻟﻠﻮﺣﺎت اﻟﺘﺼﻤﯿﻤﯿﺔ
اﻋﺘﻤﺎد أﻋﻤﺎل اﻟﻤﻮﻗﻊ
اﻋﺘﻤﺎد اﻟﻠﻮﺣﺎت اﻟﺘﻨﻔﯿﺬﯾﺔ
ﻋﻤﻞ اﻟﻤﻘﺎﯾﺴﺔ اﻟﻔﻨﯿﺔ
Design Executive اﻋﺘﻤﺎد اﻟﻠﻮﺣﺎت اﻟﺘﻨﻔﯿﺬﯾﺔ
اﻋﺘﻤﺎد ﻣﺴﺘﺨﻠﺼﺎت
ﻋﻤﻞ ﻗﺎﺋﻤﺔ اﻟﻤﻮردﯾﻦ V.L
Contactor
ﻋﻤﻞ ﺗﺴﻌﯿﺮ اﻟﻤﺸﺮوع
ﻋﻤﻞ اﻟﻠﻮﺣﺎت اﻟﺘﻨﻔﯿﺬﯾﺔ ﺗﻧﻔﯾذ اﻟﻠوﺣﺎت اﻟﺗﻧﻔﯾذﯾﺔ
اﻟﻌﺮوض اﻟﻔﻨﯿﺔ واﻟﻤﺎﻟﯿﺔ Technical Office Site Engineer ﺗﺳﻠﯾم اﻻﻋﻣﺎل ﻟﻼﺳﺗﺷﺎري
ﺗﺠﮭﯿﺰ ورﻗﯿﺎت اﻟﻤﺸﺮوع ﻋﻣل ﻣﺳﺗﺧﻠﺻﺎت
ﻋﻤﻞ ﻟﻮﺣﺎت As-built
Eng-Ahmed Shuhayb أﺳﯾـــك ASEC - asec.work أﺳﯾـــك ASEC - 0020 1093460618
Tel: +20 10934 60618
Email: [email protected]
Types of Drawings
Tender , IFC – Issued For Construction , Shopdrawing , As-Built
Documentation
RFA - Request For Approval
طﻠب اﻋﺗﻣﺎد ﻣواد او ﻣوردﯾن
Eng-Ahmed Shuhayb أﺳﯾـــك ASEC - asec.work أﺳﯾـــك ASEC - 0020 1093460618
Tel: +20 10934 60618
Email: [email protected]
Arch – Details
Arch – Details
False Ceiling
60x60 cm
Arch – Details
False Ceiling
Gypsum Boards
Arch – Details
False Ceiling
Bulkhead
Arch – Details
False Ceiling
Hidden Grille
Arch – Details
Open Ceiling
General – Notes
Description Unit
Heat Load TR – KW – Btu/Hr.
HVAC – Notes
Estimation Loads
• General Spaces
High Density - 20 square meter / 1 TR
Medium Density - 25 square meter / 1 TR
Small Density - 30 square meter / 1 TR
1 TR - 300 : 400 CFM – Return
• Medical Spaces
ACH – (10 , 12 , 15 , 20 , 25 )
CFM = (Volume x ACH)/ 1.7
1 TR – 115 : 170 CFM – T. Fresh
HVAC – Notes
AC Units
HVAC – Notes
Air Terminal
Square Diffuser Linear Slot Diffuser
• Neck Size – 18x18” – 400:600 CFM • 1 m x 2 Slot – 100:150 CFM
• Neck Size – 15x15” – 300:400 CFM • 1 m x 3 Slot – 150:200 CFM
• Neck Size – 12x12” – 200:250 CFM • 1 m x 4 Slot – 200:300 CFM
• Neck Size – 9x9” – 100:150 CFM
• Neck Size – 6x6” – 50:100 CFM
Bar Grille
• 1 m x 10 cm – 250:300 CFM
Round Diffuser • 1 m x 15 cm – 400:550 CFM
• Neck Size – 14” – 400:600 CFM • 1 m x 20 cm – 500:650 CFM
• Neck Size – 12” – 400:450 CFM
• Neck Size – 10” – 300:400 CFM
• Neck Size – 8” – 150:250 CFM
• Neck Size – 6” – 50:100 CFM Perforated Diffuser
• Neck - 10” – 350 CFM
• Neck - 8” – 200 CFM
HVAC – Notes
Duct Design
Duct Size
• Air Flow (CFM)
• Pressure Drop
0.05:0.08 Inwg/100ft - FCU
0.08:0.1 Inwg/100ft - AHU
0.12:0.15 Inwg/100ft - FAN
• Aspect Ratio
1:4
• Main Duct Depth > Branch Duct Depth
• Duct Width > Air Terminal Size
ESP
• ESP= (Duct Path + Equal Fitting) x (0.08 Inwg/100ft)
+ Pressure Drop (Accessories)
HVAC – Notes
Pipe Design
Pipe Size
• Flow Rate (GPM)
• Pressure Drop
4 ft / 100 ft
Pump Head
HVAC – Notes
Plumbing – Notes
Plumbing – Notes
Plumbing – Notes
Firefighting – Notes
Hose Cabinet
• Class 1
• Class 2
• Class 3
Fire Extinguishers
• Dry Chemicals
• Wet Chemicals
• Co2
Sprinkler System
• Pendent
• Upright
• Side Wall
Firefighting – Notes
System Components
• Pump or Cylinders
• Zone Control Valve
• Steel Pipes
• Sprinkler or Nozzle
• Alarm Detectors
Firefighting – Notes