Pactron Parameterliste
Pactron Parameterliste
1.1 Sortparameters
Sort_no. NN 1 2 3 4 5
target weight 50,00kg 50,00kg 40,00kg 25,00kg 20,00kg 15,00kg
Afterflow 0,40 kg 0,70 kg
dribble feed 6,30 kg 12,42 kg
dribble feed time 0,80 sec 1,20 sec
Discharge thresh. 5,00 kg 5,00 kg
tolerance plus 0,30 kg 0,30 kg
tolerance minus 0,30 kg 0,60 kg
Don't change !!
Seite/Page 1/15
Pactron Parameter-List
1.5 Systemparameters
Time actual
Date actual
Printer setup
Port 2
All other Values 0
General
Beep 1
keyboard lock 1
discharge key 1
Serial interface 1
Baud 9600
Parity even
Databits 8
Stopbits 1
protocol 2
Function 1
Priority low
Standart RS-485
Address 01.. 31
Serial interface 2
Baud 1200
Parity even
Databits 8
Stopbits 1
protocol 7
Function 1
Priority high
Standart RS-232
Address 01.. 31
Profibus
PB-Adress 11.. 18
reaction to bus fault 1
C:\Users\untung.harmanto\Documents\Mamuju\Mamuju final.com\Pactron_Parameterliste.doc
Mode 4
startbit check dis. 0
stopbit check dis. 0
Status [7 .. 0] 1010 0001
baud rate [kbaut] 500
PLC
A ( x 100 ms) time aeration filling pipe in afterflow 0
B ( x 100 ms) interval ventilation (on time) 0
C ( x 100 ms) time delay 1
D ( x 1) number of intervals aeration, fine stream 0
E ( c 1) number of intervals aeration, coarse stream 1
F ( x 100 ms) time delay Rest discharge 50
H ( x 100 ms) executive time Rest discharge 5
J ( x 1) number of Pulses after dosing 5
Don't change !!
Seite/Page 2/15
Pactron Parameter-List
1.5 Systemparameters
Inputs (description from Packer PLC and Pactron Master Terminal [I08])
I01 (probe THROW OFF MANUAL) 00
I02 (Sensor THROW OFF Automatic [non existing]) 00
I03 (Sensor BAG ON SPOUT) 00
I04 (feedback TURBINE DRIVE FAULT) 00
I05 (probe MANUAL START) 00
I06 (probe stop) 00
I07 (probe SPOUT AERATION) 00
I08 (keyboard enable/disable) 04
I13 (sensor automatic start [non existing]) 00
I14 (spare zero-volt potential for Input-Pins) 00
I15 (spare zero-volt potential for Input-Pins) 00
I16 (spare zero-volt potential for Input-Pins) 00
I17 (spare zero-volt potential for Input-Pins) 00
I19 (spare zero-volt potential for Input-Pins) 00
Outputs (description from Packer PLC and Pactron Master Terminal [O09])
O09 (FINE STREAM Weighing UnitY2) 07
O10 (AFTERDOSING Y1.2) 99
O11 (SPOUT AERATION Y6.1) 99
O12 (AERATION PACKER SILO Y6.2) 99
O21 (THROW OFF Y4) 99
O22 (COARSE STREAM Y1.1) 99
O24 (BAG FIXING and „Bag at spout sensor“ Y3) 99
O25 (FINE STREAM PLC Y2 and Turbine) 99
Setup
dynamic filter (dosage filter) 03
static filter (no motion filter) 05
time to no motion 0.30 sec
blocking time discharge 0.50 sec
dot (0) - comma (1) for display 1
enhanced resolution 0
bag load/ unload 0
display watchdog 0
min target weight 12,50 kg
max target weight 55,00 kg
Range
Range 60.05 kg
Calibration
Zero calibration 0 kg
Span calibration 40kg to 60 kg
Seite/Page 3/15
Pactron Parameter-List
2. Description all Parameters
2.1 Sortparameters
After entering and acknowledging the sort numbers you can scroll between the individual
parameters by means of the direction keys.
A newly entered value is stored by pushing the key “AE”. You can quit the menu "sort parameters"
Sort_no. by means of the key “ESC” or the F2 key.
Maximally 63 sorts can be entered.
It is also possible to change the parameters of the running as well as of another sort with the dosage
process running.
Target filling weight of the bag. The entered value must be between the minimum and maximum
target weight
target weight. (see “setup” parameters).
“After flow” is the material which still flows after completing the fine feed (sliding gate closing time).
The value which is entered here is the initial value for the in-flight controller.
If the value entered here does not correspond to the real product properties, this value is corrected
by the factor which has been entered under the parameter "weight controller" (see controller
afterflow parameters).
The corrected value is stored only in the sort memory, if the parameter “automatic value copying”
has been activated (see controller parameters).
The “in flight” value should be positive. If it is negative than to much Cement is flowing out after
closing sliding gate (bag to small?).
With this parameter the duration of the fine feed can be set.
dribble feed This parameter will be optimized automatically by the controller, if the controller of the desired
duration of the fine feed has been activated (see “dribble feed time”).
If the dibble feed time is greater than zero the controller regulates automatically the main feed set
point so that the resulting fine feed is as long than the set time. That means that an automatic fine
feed adjustment will be done.
The duration of the fine feed is only controlled, if a value greater than zero has been entered in the
“dribble time controller” (see controller parameters).
If the value 0 is entered for the desired duration of the fine feed, the controller of the main feed set
dribble feed time point is deactivated.
In some borderline cases it is possible that the controller of the desired duration of the fine feed
produces useless results. In these cases the value 0 should be entered for the desired duration of
the dribble feed time; the duration of the fine feed should be controlled via the parameter “dribble
feed”.
It must be observed that the effective duration of the fine feed results from the addition of the
desired duration of the dribble feed and the blocking time of the dribble feed.
If the value falls below this “discharge" set point during a discharge or bag ejection, the output
“discharge" is reset, the input “discharge threshold" is set and the scale is ready for a new filling.
Discharge thresh. It must be observed that for this parameter a value greater than zero is entered!
C:\Users\untung.harmanto\Documents\Mamuju\Mamuju final.com\Pactron_Parameterliste.doc
If the value is higher than this “discharge" set point during and the filling is terminated, than it is not
possible to start a new filling.
The entry of the values for tolerance plus and tolerance minus is for evaluating the tolerance (only in
bagging mode) in case of a controlled filling (see controller parameters). With the help of the
tolerance plus tolerance evaluation it is possible to decide by means of the outputs "tolerance minus" and
"tolerance plus" (see following table) how the dosed weight will be treated. In case of the tolerance
evaluation it is distinguished between 4 states. These states can be evaluated with the rising edge of
the signal "discharge".
a) No tolerance: This state occurs, if the filling is interrupted by pushing the key "rest" or if it is the
question of an uncontrolled filling (only in bagging mode).
b) Tolerance good: This state occurs, if the dosed final weight is within the tolerance limits (only in
bagging mode).
tolerance minus c) Tolerance minus: This state occurs, if the dosed final weight is less than the target weight less
the parameter "tolerance minus" (only in bagging mode). In this case a top-up can be affected
subsequently.
In order to make possible a top-up see section "key additional sort parameters", items "top-up time"
and "top-up delay".
d) Tolerance plus: This state occurs, if the dosed final weight is greater than the target weight
plus the parameter "tolerance plus" (only in bagging mode).
Seite/Page 4/15
Pactron Parameter-List
Seite/Page 5/15
Pactron Parameter-List
This parameter functions only in the loading/unloading mode (in the bagging mode
it is generally dosed with main and fine feed
-> look Setup-Parameter “bag load/unload” [bagging mode]).
Also it is possible to select with this parameter whether the controller automatically sets
dosage mode
the “stop full” signal if the dosed weight exceeds the tolerances programmed in the sort
parameters, i.e. in case this bit is set and the dosed weight exceeds the programmed
tolerances the scale doesn’t set the “discharge” signal unless the “stop full” is
acknowledged by either pressing the key “test stop” or setting and resetting the external
input signal “stop full”. After acknowledging the controller sets the “discharge” signal and
the filling cycle continues as usual. This parameter functions only in the bagging mode.
x0 all fillings with main and dribble feed
x1 all fillings with main feed
0x no stop full when dosed weight exceeds tolerances
1x automatic stop full when dosed weight exceeds tolerances
This value has effects for all sorts.
The minimum duration to carry out a discharge is to preset here.
The discharge is only finished, if this time has elapsed and a value below the discharge
discharge time
threshold (Sortparameters) has been reached.
This value has effects for all sorts.
If you desire, that the scale always discharges in a certain time interval, this can be set by
this parameter.
If the scale has completed the dosage earlier than the set time, the full scale waits, before
discharge interval discharging, until the discharge interval has elapsed. If the discharge interval has elapsed
and the scale has not yet completed the actual dosage, the scale continues with the
running dosage and discharges immediately after reaching the final weight.
At packer will be done the discharging with positions and not with this time.
With this parameter the monitoring of the filling time can be activated. The entry is affected
in seconds. If the entered filling time is exceeded during the dosage, the output
max. filling time "monitoring of the filling time" is set Alarm function.
The monitoring of the filling time can be deactivated by entering the value 0.
This value has effects for all sorts.
With this parameter you can preset the size for a counting pulse. This counting pulse is
given as soon as a full pulse size value has been exceeded.
pulse size
These pulses can be used to count the cement quantity.
At Packer not used.
With this parameter the duration of the counting pulse is set.
The duration of the no-pulse period also corresponds to this entered time, i.e. if a pulse
pulse duration
duration of 0,75 seconds is entered, the minimum no-pulse period is also 0,75 seconds
until the next pulse is given.
Seite/Page 7/15
Pactron Parameter-List
The Setting range is between 0,00 and 9,99sec (most 0,5 sec).
At Packer not used.
As soon as the actual filling speed drops below the programmed values for minimum fill
speed during main and fine feed (see next two parameters) this timer starts to count down.
The timer is reset if the actual fill speed exceeds the programmed minimum fill speed
values for main and fine feed.
The Setting range is between 0,00 and 99,99sec (most 1,5 sec).
1,5 sec. because of start packing. Cement need a little time to flow into the bag.
This value has effects for all sorts.
Now, the operator has to check, if the bag is broken or the packer is empty.
bag break delay
If the bag is broken, the operator has to reset the weighing unit by pushing the
Red Stop button. After the second push, the bag holding cylinder will release the bag and
the operator can remove the broken bag.
Remark: By pushing Red Stop button once, the dosing will interrupt.
By pushing Red Stop button twice, the dosing will abort.
This value is the minimum fill speed during main feed. This value is compared with the
actual fill speed during main feed. If the actual fill speed drops below this value the “bag
break delay” timer starts to count.
fillspeed main The Setting range is between 0,00 and 99,99kg/sec (most 2,0 kg/sec).
If a 0 is entered into this value the bag break detection is disabled for the duration of the
main feed.
This value has effects for all sorts.
This value is the minimum fill speed during fine feed. For further information read “fillspeed
main”.
The Setting range is between 0,00 and 99,99kg/sec (most 0,0 kg/sec).
If a 0 is entered into this value the bag break detection is disabled for the duration of the
fillspeed dribble
fine feed.
The experience shows that enabling the fill speed dribble in a rotary packer make
no sense.
This value has effects for all sorts.
Seite/Page 8/15
Pactron Parameter-List
2.5 Systemparameters
time The entry of the date and time is required for statistics and for the printer, since in case of
various printouts the date and time are also printed.
The time format is HH,MM.
date The date format is dd.mm.yy or mm.dd.yy
depending on the setting of the parameter “Metric” in the “Setup” menu
Printer setup
With this parameter it can be set to which interface the printer is connected.
Port 1 COM 1
2 COM 2
Here it can be set which printer functions are to be enabled. A printer function can be enabled, if
a 1 is entered at the corresponding position. If a 0 has been entered, the function is blocked.
It is counted from the left to the right. The functions of the individual positions can be taken from
the following table.
1XXXXX enabling the final sum printout
X1XXXX enabling the start printout
Enables
(only active, if the sum printout has been enabled)
XX1XXX enabling the net weight printout
XXX1XX enabling the gross printout
XXXX1X enabling the tare printout
XXXXX1 enabling the test printout (see key "test stop")
111111 all functions enabled
With this parameter it is set how many lines the paper is fed
Linefeed before the final total printout.
With this parameter the number of characters of the left indent
Print offset for the final printout is set.
If this parameter is set to 1, the total weight is printed with a wide font.
Wide font
If this parameter is set to 0, the total weight is printed with a normal font.
This parameter indicates whether the paper is fed by a total page
Form feed
after the final printout (FF=1) or not (FF=0).
Arithm. mean value In case this parameter is set to a value larger than zero, the mean value of the entered number
(Softwareversion ≥ of bags will be calculated and printed.
V2.1B) Set this parameter to zero to disable this function.
If for this parameter a value unequal 0 is entered, the parameters are printed according to the
following table.
If the value 0 is entered, the parameters are not printed.
It must be observed that depending on the printing and data transfer speed the printout of the
C:\Users\untung.harmanto\Documents\Mamuju\Mamuju final.com\Pactron_Parameterliste.doc
sort parameters (in case of function 3 and 4) can take several minutes.
Print parameters After finishing the printout the controller automatically resets this value to 0.
0 no printout
1 printing the calibration parameters
2 printing all parameters without sort parameters
3 printing only the sort parameters
4 printing all parameters
General
With this parameter the beep of the keys can be activated or deactivated.
beep 0 deactivated
1 activated
With this parameter it can be set whether the entire keyboard or only the entry of parameters is
disabled or enabled via the 24V input.
1 blocking of the entry of parameters
keyboard lock
2 blocking of the keyboard
3 enabling of the entry of parameters
4 enabling of the keyboard
With this parameter the key “discharge” can be enabled or disabled.
0 disabling of the key “scale discharge”
discharge key
1 enabling of the key “scale discharge"
Seite/Page 9/15
Pactron Parameter-List
Serial interface 1
In this menu you can set all parameters relevant for the interface. A setting can be changed with the keys
"⇑ " and "⇓ ". The acceptance of a value and the switch-over to the next parameter is effected by means of the
key “AE”. With the key “CE” the original value of the parameter can be restored as long as the “AE” key has
not been pushed. In detail the following settings can be affected:
If something changes, it can be that there is no data exchange between “Pactron Master Terminal” and
weighing Unit from the spout.
With this parameter the baud rate of the interface can be set. The following baud rates
baud
can be selected: 300; 1200; 2400; 4800; 9600; 19200
parity For the parity of the data transfer the following settings are possible: Even; Odd; No
databits For the number of data bits the following settings are possible: 7; 8
stopbits For the number of stop bits the following settings are possible: 1; 2
Various protocols and procedures can be selected for the data transfer. The following
settings are possible:
0 no data output
1 Display
2 - Reserved -
3 9.028 (printer appropriate for verification)
protocol 4 Siemens 3964
5 Siemens 3964R
6 --- Reserved ---
7 ASCII (= no protocol)
8 Remote display protocol (STX, n, n-Daten, BCC)
9 MODBUS ASCII protocol
10 - Reserved -
With this menu option it is possible to set the function of the interface, i.e. which data
are to be sent or received via the interface.
0 no data output
1 standard communication
2 output of zero and area reference (only for test purposes)
function
3 communication as per “Kellogg” specification
4 output of date, time, filling counter and last filling weight
5 remote display actual weight output
6 remote display summed-up weight output
7 output of date, time, consecutive number and total sum just
In order to eliminate an initialization conflict in case of different protocols, it is
necessary to indicate the priority (see corresponding description of the protocol). In
priority
case of doubt this parameter should be set to “HIGH”.
The following settings are possible: High; Low
By means of this parameter the interface standard
(e.g. RS-232, RS-422, RS-485, TTY) can be selected.
The interface standards available depend on the interface and the installed options, i.e.
Standart not all interface standards shown in the menu may be installed. Contact manufacturer
for details on the installed interface options.
To select among the interface standards you can scroll up and down by means of the
arrow up/down keys. Select the interface standard by pressing the AE key.
For several communication functions it is necessary to assign an interface address to
the controller. The above shown parameter is the protocol address in the range of 1..31
of this controller on the particular interface. Please keep in mind that an address can
be assigned only once in a network.
address
For point to point protocols the setting of this parameter doesn’t care.
The address belongs to the spout number (Spout No. 3 address 03).
Seite/Page 10/15
Pactron Parameter-List
Profibus
The values available in this menu are further described in the separate PROFIBUS-DP manual.
This is the protocol address in the range of 11..41 of this controller on the particular
interface. Please keep in mind that an address can be assigned only once in a
PB-Adress network.
The address belongs to the spout number + 10 (Spout No. 3 address 13) and
is set in the Hardware-Configuration from Step 7, too.
It can be selected what should the controller do in a case of bus fault.
reaction to bus fault
1 Close all Valves and stop drives?
mode 4
startbit check dis. 0
stopbit check dis. 0
Only for displaying. If it is like this: 1010 0001 than it is everything fine.
Status [7 .. 0]
In case of fault look at Profibus-DP manual.
The baud rate must be the same what is set in the Hardware-Configuration from
baud rate [kbaut]
Step 7 (most 500kbaut)
PLC
The values shown in this menu are variables for the program of the optional plc board. The function of each
value is determined by the plc program, i.e. that this value can be a timer, counter, etc. Please read the
software documentation of your plc program for further details.
The range of each value is 000.255.
The 8 values are named as follows: A, B, C, D, E, F, H, J. The newly entered value takes effect immediately
after pressing the “AE” key.
A ( x 100 ms) Set additional air at filling pipe only in after flow. For example to empty spout pipe.
Set additional air at filling pipe interval ventilation (on time). If the feeling is that it is too
B ( x 100 ms)
much air in cement reduce the time.
C ( x 100 ms) Set additional air at filling pipe interval ventilation (off time)
Set numbers of intervals from additional air at filling pipe interval ventilation in fine
D ( x 1)
stream.
Set numbers of intervals from additional air at filling pipe interval ventilation in course
E ( x 1)
stream. If the feeling is that it is too much air in cement reduce the numbers.
F ( x 100 ms) Set the starting point of rest discharge (>=50)
H ( x 100 ms) Set executive time of Rest discharge (<=50)
Number how many times should be done an after dosing when bag do not reach his
J ( x 1) target value (“tolerance minus”; sort parameters) (top up time and top up delay;
advanced sort parameters)
Seite/Page 11/15
Pactron Parameter-List
Inputs
In this menu you can observe the function to each parallel 24VDC input. The parameter will be set automatically by stop and
start the Packer PLC (OB100). The Inputs are only used in Packer PLC. Only Pin I08 is used in Pactron Master Terminal.
The inputs are marked according to the following syntax: “Ixx”. “I” = input and “xx” = the pin number at the connector XS3,
for example “I06” means input at pin number 6 of connector XS3. The 2-digit number on the right side of the display
represents the function number.
Example: If you wish to assign the function "compressed air active" to the input at pin 16, you must write function
number “07” to Input-Pin “I16” (DBxx.DBB48) in OB100.
Attention:
It must absolutely be observed that the function 6 is not assigned (for internal purposes only) and that no input
function is assigned twice. If an input function is assigned twice both occurrences are reset to function 00!
Pin 18 (brown/blue) is external 24 Volt power supply and Pin 23 (white/pink) is 0 Volt potential power supply.
00 pin has no function
I01 violet (00) 01 stop full
02 start bagging
03 residual weighing
I02 black (00) 04 keyboard enable/disable
05 bottom flap closed
06 (internal function; function number cannot be assigned!)
07 compressed air active
I03 red (00) 08 hopper under scale is empty
09 --- free ---
10 print and clear total sum
I04 blue (00) 11 1.sort bit (1)
12 2.sort bit (2)
13 3.sort bit (4)
I05 pink (00) 14 4.sort bit (8)
15 5.sort bit (16)
16 6.sort bit (32)
17 enable scale discharge (level active)
I06 grey (00) 18 enable filling (level active)
19 enable filling and scale discharge
20 start loading mode
I07 yellow (00) 21 start unloading mode
22 enable scale discharge (edge active)
23 enable scale discharge
(bagging mode edge active / loading and unloading mode level active)
I08 green (04) 24 interruption/abort
25 enable top-up (==> each filling controlled)
26 acknowledge error
I13 black/weight (00) 27 force taring or force afterflow control
28 clear tare memory
29 tare
I14 brown/green (00)
30 disable weight evaluation
31 send last individual weight (#date#hour#filling counter #individual weight)
I15 brown/red (00) 32 Product in prehopper available
33 direct input of target quantity
34 increase offset by one increment
I16 white/yellow (00) 35 decrease offset by one increment
36 print current weight on scale as total sum (for static scales only)
37 enable bag break detection
I17 white/yellow (00) 38 check tolerance of actual weight on scale (for static scales only)
39 complete partially filled bag (=start bagging without taring)
40 display menu to enter target weight of actually selected sort
I19 red/pink (00) 41 online print and clear total sum
42 batch number is needed before starting is enabled
43 display menu to enter the batch number
I20 green/pink (00) 44 start subtracting bagging
45 terminate/acknowledge bagging dosage
Seite/Page 12/15
Pactron Parameter-List
Outputs
In this menu you can allocate a function to each parallel 24VDC output. The parameter will be set automatically
by stop and start the Packer PLC (OB100). The Outputs are only used in Packer PLC. Only Pin O09 is
controlled from Pactron Master Terminal.
The outputs are marked according to the following syntax: “Oxx”. “O” = output and “xx” = the pin number at the
connector XS3, for example “O09” means output at pin number 9 of connector XS3. The 2-digit number on the
right side of the display represents the function number.
Example: If you wish to assign the function "ready for start" to the output at pin 11, you must write
function number “12” to Output-Pin “O11” (DBxx.DBB54) in OB100.
Seite/Page 13/15
Pactron Parameter-List
Setup
In order to change the setup parameters please proceed as follows:
1. Push the “CAL” key.
2. Push the F2 key “Setup”.
The desired values can be entered by means of the numeric keypad. You can scroll between the individual
parameters by means of the direction keys. A newly entered value is stored by pushing the key “AE”. You can
quit the setup menu with the keys “ESC” or F2.
The key “CAL” functions only, if the keyboard has been enabled via the parallel input “keyboard”. Moreover, the
access to the “SETUP” parameters must be enabled by removing the jumper in the load cell connector. If the
scale is in the custody transfer mode and the load cell plug is opened, the gauge plugging will get damaged. In
such a case please inform the responsible Office of Weights and Measures immediately
By means of this parameter building vibrations influencing negatively the
weighing procedure can be dampened. It applies that the higher the filter
setting the larger the vibration damping. When setting the filter it should be
observed that the smallest possible filter is set, since a larger filter setting
increasingly reduces the scale reaction time. The dynamic filter is active during
dynamic filter (03) the dosage.
(dosage filter) The static filter is essential for the no motion recognition. When entering the
filter it must be observed that the static filter is set larger than or equal to the
dynamic filter.
01 0,10 sec.
02 0,20 sec.
03 0,40 sec.
04 0,60 sec.
05 0,80 sec.
06 1,00 sec.
07 1,20 sec.
08 1,40 sec.
static filter (05) 09 1,60 sec.
(no motion filter) 10 2,00 sec.
11 2,50 sec.
12 3,50 sec.
13 4,50 sec.
14 5,50 sec.
15 7,00 sec.
The time to no motion is the dwell time of the scale within ±1d before a weight
time to no motion (0,3 sec.) evaluation is affected. The scale no motion is also indicated in the scale
display by means of the no motion symbol. The input area: 0,1…1,5 seconds.
The entry is affected in seconds and indicates the period during which no
blocking time discharge
evaluation of the main feed set point is effected after the discharge signal has
(0,5sec.)
dropped. Input area: 0,1...1,0 seconds.
The indication “point” or “comma” shows that the weight display uses a “,” or
only a “.” as decimal character. Moreover, in the setting “comma” a “B” is
dot (0) - comma (1) for display
displayed for gross. If the display is set to “point” a “G” is displayed instead of
(1)
the “B”. The setting “point” or “comma” does not influence the unit! Input
options: 0=point, 1=comma (default).
An increased resolution in the weight display reveals that the digit increment
set in “range” is displayed with a resolution increased by the factor 10. If the
weight display has been set to an increased resolution, it is not possible
to start the plant. The state of the increased resolution is reset after resetting
enhanced resolution (0)
or powering up the controller. In case of an increased resolution the “zero
setting key” and the “tarring key” are enabled, i.e. in case of a no motion the
displayed weight can be set to zero or tarred. Input options:
0=normal digit increment (default), 1=increased resolution activated.
Seite/Page 14/15
Pactron Parameter-List
With this parameter it can be set whether the scale is operated
in the bagging mode or
in the loading/unloading mode or
in the bagging and loading/unloading mode.
bag load/ unload (0) 0 bagging mode
1 loading/unloading mode
2 bagging and loading/unloading mode
3 static scale
Packer is using mode 0.
With this parameter, you can specify if the scale control should continue to
work in the normal manner in the event of a communication failure with the
scale display (input = 0), or if the scale control should abort the ongoing
display watchdog (0) dosage process and give out the error message Error 25. The scale control
remains blocked till communication with the display is established once again.
0 disabled
1 enabled
The minimum or maximum target weights are the preset limit values for
min target weight (12,50 kg) entering a filling quantity (see description of the key “sort parameters”). It must
be observed that the minimum desired value can be less than or equal the
max target weight (55,00 kg) weighing range and that the maximum desired value can be larger than or
equal the minimum desired value and less than or equal the weighing range.
Range
In this window it is possible to adjust the unit (g, kg, t, lb) which will be
displayed. The maximum desired value must be larger than or equal the
Range (60,05 kg)
minimum desired value, but larger than the max target value. The ,05 from
60,05 means that accuracy what the controller is displaying is 50 grams.
Calibration
The actual preload of the scale is displayed and is set to zero by pushing “AE”.
Zero calibration (0 kg)
Only press “AE” without weights until this Symbols are ► 0 ◄ displayed.
The maximum load is displayed as default value. If you would like to calibrate
the scale with another weight. This weight should be checked before at an
extra weighing unit. The accuracy from the weighing is better with larger
calibrations weights (but not more than the Range). It must be entered the
Span calibration exact weight of calibration weight by means of the numeric keypad.
(40kg to 60 kg) Now the previously entered weight must be placed on the scale and
subsequently acknowledged with “AE”.
Attention:
Put first the calibration weights at the spout before pressing “AE”
(performing the span calibration)
Seite/Page 15/15