Address: DC Road, Underpass, Sui Gass Chowk, Opposite UBL, Ali Plaza Proposal Date Today
Branch office: Bahria Town, Lahore Validity Date 3 days after quotation
Contact # 0325-0656565 & 03234100970 Our Reference Grid Tied
Email: [email protected] Proposal Type Residential
Customer : Quote/Project Description
Client Name:
Name Plate Capacity: 6540 W DC peak PV
Email Address Inverter Capacity: 10000W Grid tird AC
Simulated 1st Year Power Generation *9614 kWhr estimated and save up 480,690 rupees per year.
Whenever utility power is interrupted, System does not produce electric owing to anti-sliding
Phone: protection, even there is sun light available. Electricity units' generation per month are 800 KWh and
save 40,058 per month . *Simulation
results depends on solar irradiation ,cloudy days, other envronmental conditions and availability of
Site: Grid.
Payback period is years: 2.49
Components Make & Model Specifications Quantity Amount in PKR
Solar Panels 6540 W
• High Output power
• Less shading lose
• Low resistive lose
• Better Mechanical loading
tolerance
• 0.55% degradation over 25
Solar PV Modules Teir I like:JA Solar, Mono
years
Perc, Half cell 545W, documented panels 12 600,372
• Efficiency Certificates: IEC
with 25 years performance warranty
61215,
• IEC 61730,
• UL 1703,
• ISO 9001:2008,
• ISO 14001:2004,
• BS OHSAS 18001:2007
On-Grid Inverter
• Pure Sine-wave, III-Phase
• On-Grid function
• 2 MPPT Charge controller, 2
Hi Performance & Efficent: Sunways 10 kw, MPPT input
3phase, grid tied with 5yeaars • P.F > 0.99, Efficiency 98%
1 302,400
Replacement Warranty (10 years • String Monitoring
optional) and mobile online monitoring • IP 66, all Integrated Protection
System
To communicate with Wapda: to
Green Meter sell excessive electricity units to 1 91,800
Wapda
AC and DC earhting to attain the resistance value less 4mm wire, 10mm cupper wire
Earhting 2 32,400
than 5 ohm and one foot rod and chemical
AC & DC Breakers with SPDs and Voltage
protection devices in separate plastic BOX, AC &DC , Box 1 34,560
and Changeover boxes
-Wiring (99% Copper AC & DC cables, System earthing wires as per Inverter requirements, GI Cable
DC 6mm tin coated, and AC 6mm 4 core 32,400
Tray, Nuts, bolts, MC4 connectors IP65, luxes
Other Accessories UPVC conduits pipe, Perfurated Ducts, PVC tape, cable tie, rawal plugs, nuts bolts and other 16,200
Aluminium 2 mm profile with SS
PV Stand: L3 with universal title angle 4 37,584
nut bolts
Civil Work Concrete blocks with proper iron supports to provide suspenstions during high velocity wind 24 9,072
Transportation 1 12,960
Installation and Commissioning 1 28,253
Total Solar PV System delivered and tested Price in PKR PKR 1,198,000
Advanced payment received
Net Amount payable
PV module warranties: 12 years Product warranty. 90% linear performance warranty as per OEM terms for 25 years
Inverter warranty: 10 years for Inverter as per OEM terms & conditions. Post installation workmen services for 06 months will be free. For site, Rs. 4000 per visit per day
will be charged. Any alteration in our installed system or increase in Load, and DISCO interruptions & power variations will release us from warranty claims.
As per 2nd schedule part iv clause 77 of income tax rules, 2019, Solar Installers are exempted from WHT deductions
As per Sales Tax Act 1990 (Schedule 6, Table 2, Sr # 110) Sale of Solar equipment is exempt from Sales Tax.
Caution Caveat: Getting Netmetering generation licence is challenging and doesn’t gurantee success or timely service from DISCO depsite the law &
fullfilling doc requirements from our associates..
Notes & terms
Any component other than quoted items, any type of mechanical or civil work or additional cable/fuses, wires laying will be provided by client or charged in addtion. These components
Brand may change, if order is placed after 10days and depends upon availability
Buyer shall release and indemnify, defend and hold Seller and its Representatives harmless from and against any and all Claims caused by, resulting from, or incidental to the Assumed Obligations of the
total installations. Force Majure is applicable
Payment will be 90% advance, and 10% after project completion within 5 days. ….. PKR 1,078,200
Execution time: 7-10 Normal working days, after advance.
Safe House keeping of components/spares/tools when work-in-progress is sole responsibility of client.
Our scope of work
We will provide training & post installation service manuals to local site staff
PV Modules, mounting structure installation on the roof at first marked location. No relocation is in scope
Provide DC and AC cables for interconnection between the PV panels, inverter.
Inverter and storage installation, AC & DC cables laying. No civil work & Grill making is in scope & your internal wiring
AC Cable between the inverter and closest AC Disconnect or Distribution box to the inverter
Start-up & Commissioning is our scope.
Customer' own AC Distribution box/ internal/ earthing, phase Neutral wiring at site should be in order & out of our scope.
For Apollo Electric Energy Solutions Client Acceptance