0% found this document useful (0 votes)
51 views

CS Ar-08

This document provides technical specifications for the CS AR-08 safety module. The module can be used for emergency stops, end position monitoring, and connection to safety sensors. It has inputs for 1-2 channels, automatic or manual start options, and 2 NO safety contact outputs. The module operates from 12Vdc, 24Vac/dc, 120Vac, or 230Vac power and meets safety standards including SIL CL 3, PL e, and category 4. Key specifications include an operating temperature of -25°C to +55°C, over 100,000 electrical cycles, and contact switching of 230Vac and 6A.

Uploaded by

Marlon Beckert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views

CS Ar-08

This document provides technical specifications for the CS AR-08 safety module. The module can be used for emergency stops, end position monitoring, and connection to safety sensors. It has inputs for 1-2 channels, automatic or manual start options, and 2 NO safety contact outputs. The module operates from 12Vdc, 24Vac/dc, 120Vac, or 230Vac power and meets safety standards including SIL CL 3, PL e, and category 4. Key specifications include an operating temperature of -25°C to +55°C, over 100,000 electrical cycles, and contact switching of 230Vac and 6A.

Uploaded by

Marlon Beckert
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

10A Safety module CS AR-08

Technical data
Housing
Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94
Protection degree acc. to EN 60529: IP40 (housing), IP20 (terminal strip)
Dimensions: see page 355, design A
General data
SIL level (SIL CL) up to: SIL CL 3 acc. to EN 62061
Performance Level (PL) up to: PL e acc. to EN ISO 13849-1
Safety category up to: cat. 4 acc. to EN ISO 13849-1
Safety parameters: see page 417
Ambient temperature: -25°C…+55°C
Mechanical endurance: >10 million operating cycles
Electrical endurance: >100,000 operating cycles
Pollution degree: external 3, internal 2
Rated impulse withstand voltage (Uimp): 4 kV
Rated insulation voltage (Ui): 250 V
Overvoltage category: II

Supply
Module for emergency stops, end Rated supply voltage (Un): 12 Vdc
position monitoring for movable guards, 24 Vac/dc; 50…60 Hz
120 Vac; 50…60 Hz
OSSD semiconductor outputs and 230 Vac; 50…60 Hz
magnetic safety sensors Max. DC residual ripple in DC: 10%
Supply voltage tolerance ±15% of Un
Main features 24 Vac/dc, 120 Vac, 230 Vac:
•฀For safety applications up to SIL CL 3/PL e Supply voltage tolerance 12 Vdc: -10% … +15% of Un
Power consumption AC: < 5 VA
•฀Input with 1 or 2 channels Power consumption DC: < 2W
•฀Choice between automatic start, manual start
or monitored start Control circuit
•฀Can be connected to OSSD semiconductor Protection against short circuits: PTC resistance, Ih=0.5 A
outputs, to electromechanical contacts or to PTC times: response time > 100 ms, release time > 3 s
magnetic safety sensors Maximum resistance per input: ≤ 50 Ω (15 Ω)*
•฀Output contacts: Current per input: 30 mA (70 mA)* (typical)
2 NO safety contacts Min. duration of start impulse tMIN: > 200 ms (100 ms)*
•฀Supply voltage: Response time tA: < 300 ms ( 220 ms)*
12 Vdc, 24 Vac/dc, 120 Vac, 230 Vac Release time tR1: < 20 ms (15 ms)*
•฀Possibility of parallel reset of several modules Release time in absence of power supply tR: < 200 ms (50 ms)*
Simultaneity time tC: unlimited
* Version CS AR-08•U12
Utilization categories In compliance with standards:
Alternating current: AC15 (50…60 Hz) EN 60204-1, EN ISO 13855, EN ISO 14118, EN ISO 12100, EN ISO 13850, EN 60529,
Ue (V) 230 EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN 60947-5-
Ie (A) 3 3, EN 61508-1, EN 61508-2, EN 61508-4, EN IEC 63000, EN ISO 13849-1,
Direct current: DC13 (6 oper. cycles/min.) EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95, GB/T14048.5
Ue (V) 24
Ie (A) 4 Output circuit
Output contacts: 2 NO safety contacts,
Contact type: forcibly guided
Quality marks: Material of the contacts: gold-plated silver alloy
Maximum switching voltage: 230/240 Vac; 300 Vdc
Max. current per contact: 6A
EC type examination certificate: IMQ CP 432 DM Conventional free air thermal current Ith: 6A
UL approval: E131787 Max. total current Σ Ith2: 36 A2
CCC approval: 2020970305002290 Minimum current: 10 mA
TÜV SÜD approval: Z10 18 05 75157 018 Contact resistance: ≤ 100 mΩ
EAC approval: RU C-IT.УT03.В.00035/19 External protection fuse: 4A
The number and the load capacity of output contacts can be increased by using expansion modules or
Compliance with the requirements of: contactors. See pages 295-304.
Machinery Directive 2006/42/EC, Features approved by UL
EMC Directive 2014/30/EC, Rated supply voltage (Un): 24 Vac/dc; 50…60 Hz, 120 Vac; 50…60 Hz
230 Vac; 50…60 Hz
RoHS Directive 2011/65/EU. Power consumption AC: < 5 VA
Power consumption DC: <4W
Electrical ratings: 230/240 Vac, 6 A general use,
Code structure C300 pilot duty
Notes:
- Use 60 or 75°C copper (Cu) conductor and wire size No. 30-12 AWG, stranded or solid.

CS AR-08V024 - The terminal tightening torque of 5-7 lb in.


- Only for 24 Vac/dc versions: supply from remote Class 2 source or limited voltage
limited energy.

Connection type Supply voltage Features approved by TÜV SÜD


Rated supply voltage (Un): 24 Vac/dc ± 15%,
V Screw terminals U12 12 Vdc 120 Vac ± 15%, 230 Vac ± 15%
Power consumption: 5 VA max AC, 2 W max DC
M Connector with screw terminals 024 24 Vac/dc Rated operating current (max.): 4 A
Maximum switching load (max.): 1380 VA
X Connector with spring terminals 120 120 Vac Ambient temperature: -25°C … +55°C
Storage temperature: -25 °C … + 70°C
230 230 Vac Protection degree: IP40 (housing), IP20 (terminal strip)
In compliance with standards: 2006/42/EC Machinery Directive,
EN ISO 13849-1:2015 (fino a Cat. 4 PL e), EN 60947-5-3:2013,
EN 61508-1:2010 (fino a SIL 3), EN 61508-2:2010 (fino a SIL 3),
EN 61508-4:2010 (fino a SIL 3), EN 62061:2005/A2:2015 (fino a SIL CL 3)

257 General Catalogue Safety 2021-2022


10A

Safety module CS AR-08


Pin assignment Function diagrams

Configuration with automatic start


A1 13 23 S33

S11 S12 S31 S52 A1/A2


S11/S12 (+/S12)

S21/S22 (+/S52)

ITALY 13/14, 23/24


PWR

CH1 tC tA tR1 tC tA tR1 tA tR


CH2

Configuration with monitored start

S21 S22 S35


A1/A2
A2 14 24 S34
S11/S12 (+/S12)

S21/S22 (+/S52)

S33/S34 (START)

13/14, 23/24

tA tR1 tA tR1 tMIN tA tR

Internal block diagram Configuration with manual start

L/+
A1/A2
A1 S11 S12 S33 S52 S31 S34 13 23
S11/S12 (+/S12)

S21/S22 (+/S52)

S33/S34 (START)

K1 13/14, 23/24

tA tR1 tA tR1 tMIN tR

LED LED LED


PWR CH1 CH2 Legend:
LOGIC LOGIC tR1: release time
tMIN: Min. duration of start impulse
tC: simultaneity time tR: release time in absence of
tA: response time power supply
Notes:
K2 The configurations with one channel are obtained taking into consideration the CH1
input only. In this case it is necessary to consider time tR1 referred to input CH1,
time tR referred to the supply, time tA referred to input CH1 and to the start, and
time tMIN referred to the start.

A2 S21 S35 S22 14 24

N/-

Input configuration

OSSD semiconductor outputs (e.g. ST, NS, NG series or light barriers) Automatic start
Input configuration with manual start With regard to the
1 channel 2 channels indicated diagrams, bridge
the start button between
+ +
S33 and S34 in order to
24 VDC 24 VDC
OSSD OSSD1 OSSD2 activate the automatic
- - start module.
S34 S34
A1 S12 S52 S33 A1 S12 S52 S33

CS AR-08 CS AR-08 Monitored start

S21 S22 S35 S34 A2 S21 S22 S35 S34 A2


With regard to the S21 S21
indicated diagrams,
remove the connection
between the S22 and
S35 terminals in order to
activate the monitored
Emergency stop circuits start module. S22 S35 S22 S35
Input configuration with manual start
1 channel 2 channels Monitoringofmovableguardsandmagneticsafetysensors
The safety module can
L/+
L/+ monitor emergency stop
circuits, control circuits for
movable guards as well as
A1 S11 S12 S31 S33
A1 S11 S12 S31 S33 magnetic safety sensors.
CS AR-08 Replace the emergency
CS AR-08
stop contacts with switch
S21 S22 S35 S34 A2
S21 S22 S35 S34 A2 contacts or sensor con-
tacts.
The sensors can only be
N/-
N/- used in 2-channel confi-
guration.
The diagram does not show the exact position of the terminals in the product

Application examples See page 305

General Catalogue Safety 2021-2022 258