Technical data
Housing
Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94
Protection degree acc. to EN 60529: IP40 (housing), IP20 (terminal strip)
Dimensions: see page 355, design A
General data
SIL level (SIL CL) up to: SIL CL 3 acc. to EN 62061
Performance Level (PL) up to: PL e acc. to EN ISO 13849-1
Safety category up to: cat. 4 acc. to EN ISO 13849-1
Safety parameters: see page 417
Ambient temperature: -25°C…+55°C
Mechanical endurance: >10 million operating cycles
Electrical endurance: >100,000 operating cycles
Pollution degree: external 3, internal 2
Rated impulse withstand voltage (Uimp): 4 kV
Rated insulation voltage (Ui): 250 V
Overvoltage category: II
Supply
Module for emergency stops, end Rated supply voltage (Un): 12 Vdc
position monitoring for movable guards, 24 Vac/dc; 50…60 Hz
120 Vac; 50…60 Hz
OSSD semiconductor outputs and 230 Vac; 50…60 Hz
magnetic safety sensors Max. DC residual ripple in DC: 10%
Supply voltage tolerance ±15% of Un
Main features 24 Vac/dc, 120 Vac, 230 Vac:
•For safety applications up to SIL CL 3/PL e Supply voltage tolerance 12 Vdc: -10% … +15% of Un
Power consumption AC: < 5 VA
•Input with 1 or 2 channels Power consumption DC: < 2W
•Choice between automatic start, manual start
or monitored start Control circuit
•Can be connected to OSSD semiconductor Protection against short circuits: PTC resistance, Ih=0.5 A
outputs, to electromechanical contacts or to PTC times: response time > 100 ms, release time > 3 s
magnetic safety sensors Maximum resistance per input: ≤ 50 Ω (15 Ω)*
•Output contacts: Current per input: 30 mA (70 mA)* (typical)
2 NO safety contacts Min. duration of start impulse tMIN: > 200 ms (100 ms)*
•Supply voltage: Response time tA: < 300 ms ( 220 ms)*
12 Vdc, 24 Vac/dc, 120 Vac, 230 Vac Release time tR1: < 20 ms (15 ms)*
•Possibility of parallel reset of several modules Release time in absence of power supply tR: < 200 ms (50 ms)*
Simultaneity time tC: unlimited
* Version CS AR-08•U12
Utilization categories In compliance with standards:
Alternating current: AC15 (50…60 Hz) EN 60204-1, EN ISO 13855, EN ISO 14118, EN ISO 12100, EN ISO 13850, EN 60529,
Ue (V) 230 EN 61000-6-2, EN 61000-6-3, EN 61326-1, EN 60664-1, EN 60947-1, EN 60947-5-
Ie (A) 3 3, EN 61508-1, EN 61508-2, EN 61508-4, EN IEC 63000, EN ISO 13849-1,
Direct current: DC13 (6 oper. cycles/min.) EN ISO 13849-2, EN 62061, UL 508, CSA C22.2 n° 14-95, GB/T14048.5
Ue (V) 24
Ie (A) 4 Output circuit
Output contacts: 2 NO safety contacts,
Contact type: forcibly guided
Quality marks: Material of the contacts: gold-plated silver alloy
Maximum switching voltage: 230/240 Vac; 300 Vdc
Max. current per contact: 6A
EC type examination certificate: IMQ CP 432 DM Conventional free air thermal current Ith: 6A
UL approval: E131787 Max. total current Σ Ith2: 36 A2
CCC approval: 2020970305002290 Minimum current: 10 mA
TÜV SÜD approval: Z10 18 05 75157 018 Contact resistance: ≤ 100 mΩ
EAC approval: RU C-IT.УT03.В.00035/19 External protection fuse: 4A
The number and the load capacity of output contacts can be increased by using expansion modules or
Compliance with the requirements of: contactors. See pages 295-304.
Machinery Directive 2006/42/EC, Features approved by UL
EMC Directive 2014/30/EC, Rated supply voltage (Un): 24 Vac/dc; 50…60 Hz, 120 Vac; 50…60 Hz
230 Vac; 50…60 Hz
RoHS Directive 2011/65/EU. Power consumption AC: < 5 VA
Power consumption DC: <4W
Electrical ratings: 230/240 Vac, 6 A general use,
Code structure C300 pilot duty
Notes:
- Use 60 or 75°C copper (Cu) conductor and wire size No. 30-12 AWG, stranded or solid.
S21/S22 (+/S52)
S21/S22 (+/S52)
S33/S34 (START)
13/14, 23/24
L/+
A1/A2
A1 S11 S12 S33 S52 S31 S34 13 23
S11/S12 (+/S12)
S21/S22 (+/S52)
S33/S34 (START)
K1 13/14, 23/24
N/-
Input configuration
OSSD semiconductor outputs (e.g. ST, NS, NG series or light barriers) Automatic start
Input configuration with manual start With regard to the
1 channel 2 channels indicated diagrams, bridge
the start button between
+ +
S33 and S34 in order to
24 VDC 24 VDC
OSSD OSSD1 OSSD2 activate the automatic
- - start module.
S34 S34
A1 S12 S52 S33 A1 S12 S52 S33