0% found this document useful (0 votes)
67 views10 pages

Chiller Option Kit

The document describes an optional chiller control kit for LG central controllers. The kit allows controllers to remotely monitor and control chillers. It installs via an SD card and adds a "C+" to the controller's version number. Instructions are provided on installing the kit and indicating successful installation. The document also lists compatible chiller types and provides an overview of the cloud gateway product, including its specifications, ports/functions, and how to connect it for remote control and monitoring via the ThinQ app.

Uploaded by

Mohamed Radjradj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views10 pages

Chiller Option Kit

The document describes an optional chiller control kit for LG central controllers. The kit allows controllers to remotely monitor and control chillers. It installs via an SD card and adds a "C+" to the controller's version number. Instructions are provided on installing the kit and indicating successful installation. The document also lists compatible chiller types and provides an overview of the cloud gateway product, including its specifications, ports/functions, and how to connect it for remote control and monitoring via the ThinQ app.

Uploaded by

Mohamed Radjradj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

TM HVAC Solution

2.3 Product Description


2.3.8 Chiller Option Kit

LG central controller series provide Chiller option kit for chiller remote control and cycle monitoring (Optional)

2.3.8.1 Features

Indication Label of SD Card for


Chiller Option Kit Chiller Option Kit installation

! CAUTION
If any product is used other than our standard product and a problem occurs, we don't take any responsibility
regarding the problem. Please keep away from using other products.

2.3.8.2 Installation
Central Controller

• Chiller Option Kit installation of LG HVAC Solution product should be conducted by a specialized installation service
engineer.
• Chiller Option Kit installation can be proceeded with a SD Card.
• The SD Card can install Chiller Option Kit in one LG HVAC Solution product.

1. Insert the SD Card in the LG HVAC Solution product. If a backup SD Card is inserted, replace it with a Chiller
Option Kit SD Card.

168 _ Central Controller


TM HVAC Solution

2.3 Product Description


2. Reboot the LG HVAC Solution. When LG HVAC Solution is rebooted, check the version. Installing Chiller Option
Kit adds C+ to the version. If you have a back up SD Card, remove the Chiller Option Kit SD Card and insert the
backup SD Card.
- Version before installation: 1.00.0
- Version after installation: 1.00.0.C+

3. After completing installation, attach the indication label of Chiller Option Kit installation to LG HVAC Solution prod-
uct to which Chiller Option Kit is installed by referring to the example below.
• Attachment example for product indication label of Chiller Option Kit product
- Attach the product indication label at the noticeable place.

Central Controller
NOTE
• Refer to the user manual of LG HVAC Solution product for Chiller function related contents.
• The version of LG HVAC Solution product could be checked in [Environment] → [General Setting] → [Version
Information].
• Ask specialized service engineers for the verification of the LG HVAC Solution product which can install
Chiller Option Kit.

Central Controller _ 169


TM HVAC Solution

2.3 Product Description

Scroll Chiller
Turbo Chiller Absorption Chiller Screw Chiller
(Air, Water)

Chiller Option Kit O O O O


Central Controller

170 _ Central Controller


TM HVAC Solution

2.3 Product Description


2.3.9 Cloud Gateway

It is a communication gateway that enables remote control/monitoring and maintenance by linking the product to
the ThinQ server and BECON cloud server through wired/wireless LAN. You can conveniently remote control/mon-
itoring up to 16 indoor units through the ThinQ app.

2.3.9.1 Specifications & Dimensions

Wall installation plate

1. EU : CE RED Central Controller


2. India : WPC
3. Vietnam : VNTA not applicable (Power below 60mW(17dBm))

Central Controller _ 171


TM HVAC Solution

2.3 Product Description

23 mm
120 mm
Cloud Gateway

41 mm
120 mm

29 mm

2.3.9.2 Port and Function

Cloud Gateway
4 5
6

3
Central Controller

2 1



172 _ Central Controller


TM HVAC Solution

2.3 Product Description


2.3.9.3 Function List
Function Description ThinQ
Multi V ●
GHP ●
Multi ●
Interlocking products
Single ●
ERV X

Heating X

Operation Start/Stop ●
Operation Mode ●
Target Temperature ●
Remote control
Fan speed ●
Swing ●
Air Purify ●
Schedule ●
etc Electricity Monitoring ● 1)
History X

Smart Diagnosis ●
Maintenance
Cycle monitoring X

1) Available when PDI interlocking

Central Controller
● X

Central Controller _ 173


TM HVAC Solution

2.3 Product Description


2.3.9.4 Field Wiring Diagram

1) Wired LAN

Internet service
provider RS-485
Set top Box

2) Wireless LAN

ThinQ server
Central Controller

NOTE
• The Wi-Fi name and password are on the wireless router. Wi-Fi should only select 2.4 GHz.
The modem mounted on the home appliance does not support 5 GHz and cannot connect the home appliance to
the wireless router.
• WPA2 is recommended for the type of authentication and encryption of the wireless router.
• Wireless network connection quality can be affected by the surrounding wireless environment. If a failure occurs,
contact internet service provider.
• When you can't connect home appliance's modem to wireless router, use the following methods to solve.
- When a firewall is set on the wireless router, proceed after registering or releasing exceptions.
- When the Wi-Fi name is in Korean or special characters, set it as English or numeric, or combination of English
and numeric characters.
When the name contains Korean or special characters, you cannot connect.
• When the distance between the product and the wireless router is too far, the signal strength is weakened. A weak
signal can take a lot of time or fail to register the product.
• When changing the wireless router, internet service provider, or password, delete the registered product in LG
ThinQ and re-register it.
• The content of this manual may vary depending on the version of the LG ThinQ application and may change with-
out notifying the user.

174 _ Central Controller


TM HVAC Solution

2.3 Product Description


2.3.9.5 Connecting

RS485
B A

Power
GND 12V
Outdoor unit terminal block

Power

Central Controller

Central Controller _ 175


TM HVAC Solution

2.3 Product Description


■ Installation environment inspection and equipment address setting

Outdoor
unit Indoor Indoor Indoor
Cloud Gateway unit 1 unit 2 unit 3

Setting Setting Setting


address address address
00 01 0F

NOTE :
• The maximum allowable communication length guaranteed by LG Electronics is 1000m. In other words, the controller
and the farthest installed device must be installed within the distance of 1000m.
• It is recommended to use the communication cable which is more than 0.75 mm2.
• Set the address that does not overlap within the same device type.
• When multiple different wireless LAN equipment are connected to the router to which you are connecting the controller,
the wireless LAN malfunction may be caused (Such as delayed operation speed, disconnected, etc.) In this case, it is
recommended to use a separate router to connect the controller.

■ Connection of RS485 communication line


One unit of controller can connect up to 16 indoor units. When multiple devices are connected, they must be connected
in a BUS format. Otherwise, the controller may cause malfunction.
Central Controller

<Correct example : RS485 BUS format connec- <Incorrect example : RS485 STAR format con-
tion> nection>

176 _ Central Controller


TM HVAC Solution

2.3 Product Description


■ Indoor unit central control address setting
First, you need to grant address that does not overlap to each equipment (indoor unit, ventilation equipment) considering
the entire installation composition connected to one controller.
The address of the device must be set within the range of 00~0F.

Note : Granting outdoor unit and indoor unit number


If the outdoor unit product is Multi V, it is recommended to set the first digit of the address as the outdoor unit number,
and classify the second digit as the indoor unit number, so that the system composition and division can be easily identi-
fied during the address setting.

Outdoor unit(group) number Indoor unit number

Note : Setting method of indoor unit central control address


The central control address setting method may be different according to the indoor unit product or remote controller
type, so proceed the address setting by referring to the indoor unit product or wired remote controller manual.

Central Controller

Central Controller _ 177