Proportional Valve With Control Electronics
Proportional Valve With Control Electronics
Proportional Valve
with Control Electronics
www.burkert.com p. 1/3
6223
consumption
Orifice [mm]
connection
Article no.
QNn value
KVS value
Max. coil
Pressure
[l/min] 2)
function
[m3/h] 1)
current
Circuit
Power
[bar] 3)
range
water
[mA]
Port
[W]
A 2 (A) G⅜ 10 1.4 1510 0.5 - 10 300 8 134229
G½ 1.4 1510 0.5 - 10 300 8 134230
1 (P) G½ 13 2.5 2700 0.5 - 10 330 10 132202
2/2 way servo-con- G¾ 2.5 2700 0.5 - 10 330 10 282985
trolled, solenoid pro- G¾ 20 5.0 5400 0.5 - 10 530 15 222478
portional control valve G1 5.0 5400 0.5 - 10 530 15 222477
1) KVS value: Flow rate value for water, measured at + 20 °C and 1 bar pressure differential over a fully opened valve
2) QNn value: Flow rate value for air with inlet pressure of 6 bar1) , 1 bar pressure differential and + 20 °C
3) Pressure data [bar]: Overpressure with respect to atmospheric pressure; if the differential pressure over the valve exceeds 5 bar the characteristics may change.
Please note that the valves are delivered without control electronics unit and cable plug (see accessories below).
Article
no.
Dimensions [mm]
M
A
B
12
K
G
F F SW
E C H
L D
p. 2/3
6223
Note
fill out
You can
Design data for solenoid control valves the fields
directly
th e P D F file
in
Please fill out this form and send to your local Bürkert Sales Centre* with your inquiry or order before pri
nting
e fo rm.
out th
Company Contact person
Address Tel./Fax
Fluid
p1max= barg
Maximum inlet pressure
Ambient temperature °C
Additional specifications
Note Please state all pressure values as overpressures with respect to atmospheric [barg].
To find your nearest Bürkert facility, click on the orange box www.burkert.com
Reset form
p. 3/3