TriOS Catalogue (2022)
TriOS Catalogue (2022)
2022
Table of contents
A success story.
When TriOS Mess- und Datentechnik GmbH was vacationers accompany the devices, even if
founded in 1998, the further development path was certainly not consciously perceived, on their journey
not foreseeable. With the R&D project funded under along the fjords on the ships of the Hurtigruten.
the project name RAMSES by the BMBF (Federal Today, the former university spin-off, which has
Ministry of Education and Research), the foundation been managed by Rüdiger Heuermann alone since
stone for a success story in optical measurement 2000, has become a leading company in the field of
technology was laid during the founding phase optical immersion sensors.
of TriOS GmbH. RAMSES was the first spectral- In addition to the original RAMSES radiometers, the
resolution light measurement instrument available TriOS product range has expanded visibly. Innovative
on the market for use in marine research. measuring instruments for algae detection, for the
Today, the product name „RAMSES“ is measurement of smallest amounts of oil in water,
synonymous with compact, robust and reliable the reagent-free determination of nutrients and
light measurements, with over a thousand organic substances followed, whereby the business
instruments in use worldwide - the clear No. 1 in field of TriOS Mess- und Datentechnik GmbH has
the world. The instruments are routinely used to expanded far beyond the field of marine technology
measure light distribution in the water column as into water quality, drinking water and wastewater
well as for validation and calibration of advanced monitoring and many industrial applications. Among
environmental satellite data (e.g. MERIS). The other things, TriOS is one of the leading companies
sensors have proven their reliability in many adverse in the field of oil-in-water monitoring and thus makes
environmental conditions, such as in Antarctica, but a significant contribution to reducing environmental
also in unusual locations such as offshore racing pollution caused by oil discharges.
yachts in the Volvo Ocean Race. Many Norwegian With the expansion of the product range and the
increase in the number of units produced, the need TpH-D for pH. In addition, the flow rate, temperature
for production space and qualified employees as well as the turbidity-corrected PAH value can be
grew. Thus, the move to the newly built company determined.
headquarters in Rastede took place in July 2011. In addition, novel sensors for environmentally
This laid the foundation for significantly increasing relevant parameters are currently being developed
the vertical range of manufacture by means of in- in several research projects in cooperation with
house CNC machining, modern PCB assembly universities and research institutes. Many of our
and device production, and thus having all quality- customers are also partners in the development of
relevant processes in-house. In 2019, the company new products.
premises were also expanded with additional My special thanks, also on behalf of all TriOS
warehouse and production buildings to meet employees, go to these partners, without
the enormous market demand. Equipped with whom TriOS would not exist in its current form.
state-of-the-art technology, this has also allowed
development to grow and deepen in-house. Almost Rüdiger Heuermann
all TriOS products thus rightly bear the status „Made Managing Director
in Germany“. TriOS has remained true to its drive for
innovation. One of the latest TriOS products on the
market is the EGC Water Analyzer - a measuring
cabinet for determining various parameters in wash
water from exhaust gas scrubbers on ships. It
can be equipped with three types of sensors: the
enviroFlu for PAH, the TTurb for turbidity and the
1. Connect
2. Open browser
Ready!
6
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Photometer
Sensor // Photometer
7
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Photometer // OPUS
OPUS
Photometer
12SXXXXX0
Fluorometer
OPUS is the new generation of spectral sensors a web browser. Integration into existing process
for online measurement of nitrogen and carbon control systems and external data loggers has never
compounds. Through the analysis of a full spectrum, been easier.
Radiometer
Benefits Applications
eCHEM
Nitrate
Nitrat
2,5
Nitrit
Nitrite
2
Absorption [AU]
Absorption [AU]
eq
1
SAK254 TSS
TSS
SAC 254
0,5
0
190 210 230 250 270 290 310 330 350
Wavelength
Wellenlänge[nm]
[nm]
Systems
Technical Specifications
Photometer
light source Xenon flash lamp
High-end miniature spectrometer
Measure
ment tech 256 Channels
nology detector
200 to 360 nm
Fluorometer
0.8 nm/pixel
Measurement principle Attenuation, spectral analysis
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm
Radiometer
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min
eCHEM
~ 470 mm x 48 mm (10 mm path) ~ 18.5“ x 1.9“ (with10 mm path)
Dimensions (L x Ø)
Deep Sea Version: ~ 511 x 59 mm Deep Sea Version: ~ 20.1“ x 2.3“
stainless steel ~ 3 kg (with 10 mm path) ~ 6.6 lbs (with 10 mm path)
Weight ~ 2 kg ~ 4.4 lbs
titanium
Deep Sea Version: ~ 4 kg Deep Sea Version: ~ 8.8 lbs
Ethernet (TCP/IP)
Interface digital
Controller
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤8W
Power supply 12...24 VDC (± 10 %)
Measuring Range
Single parameter under optimum laboratory conditions
Path Measurement Measuring Detection Limit of Precisi-
(mm) Parameter principle Unit range limit determination on Accuracy*
Nitrate NO3-N Spectral mg/L 0...100 0.3 0.5 0.05 ± (5 % + 0.1)
Nitrite NO2-N Spectral mg/L 0...150 0.5 1.2 0.12 ± (5 % + 0.1)
Fluorometer
OPUS G2 Interface
Photometer
The easiest and fastest way of sensor integration and configuration in any process control system or data
logger via web browser:
Fluorometer
Radiometer
eCHEM
Let OPUS automatically monitor your processes and react to unexpected events or incidents with the optio-
nal "policing" feature of OPUS.
Controller
Dry Standards
Accessories
Systems
OPUS aero
Photometer
12SXXXXXX
Fluorometer
Radiometer
OPUS aero is the new generation of spectral a web browser. Integration into existing process
sensors for online measurement of nitrate and control systems and external data loggers has never
nitrite in wastewater aeration tank. By analyzing a been easier.
complete spectrum, OPUS aero is able to provide
WiFi connectivity allows laptops, tablets or
reliable readings for either NO3-N only or NO3-N and
smartphones to be easily used for control without
NO2-N, depending on the calibration.
any special application software or app installation.
eCHEM
Benefits Applications
Controller
1 0.7...36 1.3...67
2 0.35...18 0.65...33.5
Systems
Technical Specifications
Photometer
light source Xenon flash lamp
High-end miniature spectrometer
Measure
ment tech 256 Channels
nology detector
200 to 360 nm
Fluorometer
0.8 nm/pixel
Measurement principle Attenuation, spectral analysis
Optical path 0.3 mm, 1 mm, 2 mm
Radiometer
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min
eCHEM
Weight stainless steel ~ 3 kg ~ 6.6 lbs
Ethernet (TCP/IP)
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤8W
Power supply 12...24 VDC (± 10 %)
Controller
Maintenance effort ≤ 0.5 h/month (typical)
Calibration/maintenance
24 months
interval
System compatibility Modbus RTU
Warranty 1 year (EU: 2 years) USA: 2 years
NICO
Photometer
15SXXXXXX
Fluorometer
Based on the innovative instrument platform con- Equipped with our innovative G2 interface with web
Radiometer
cept of TriOS, on which OPUS, LISA and VIPER, browser configuration and internal data logger, NICO
among others, are based, NICO is a cost-effective has features that are significantly above the current-
UV photometer for nitrate determination. The three ly available devices on the market, in combination
detection channels provide precise optical nitrate with an attractive price.
determination by absorption, taking into account tur-
The uniform instrument platform of all TriOS photom-
bidity and organics, which are a problem with many
eters also stands for a uniform spare parts and con-
products currently on the market.
sumables system, which enables the use of the wide
An internal temperature correction additionally in- range of accessories available for our instruments.
eCHEM
creases the stability of the measured values. The modern G2 interface also offers fast integration
into third-party systems.
Benefits Applications
Technical Specifications
Photometer
Measurement light source Xenon flash lamp
technology detector 4 photo diodes + filter
Measurement principle Attenuation
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm
Fluorometer
Parameters NO3-N, NO3, NOx-N, NOx (calibrated with NO3 standard solution)
Measurement 1 mm path 0.5...60 mg/L NO3-N
range 10 mm path 0.05...6 mg/L NO3-N
± (5 % + 0.1 mg/L NO3-N) with 10 mm path
Measurement accuracy
± (5 % + 1 mg/L NO3-N) with 1 mm path
Turbidity compensation Yes
Radiometer
Data Logger ~ 2 GB
Reaction time T100 20 s
Measurement interval ≥ 10 s
eCHEM
Weight
titanium ~ 2 kg ~ 4.4 lbs
Ethernet (TCP/IP)
Interface digital
RS-485 (Modbus RTU)
Power consumption ≤7W
Power supply 12...24 VDC (± 10 %)
Controller
Required supervision Typically ≤ 0.5 h/month
Calibration / maintenance
24 months
interval
System compatibility Modbus RTU
Warranty 1 year (EU: 2 years) US: 2 years
NICO plus
Photometer
16AXX10X0
Fluorometer
Radiometer
The new all-rounder from TriOS - Now with a new turbidity compensation*
As a new all-rounder, NICO plus not only offers the Equipped with our innovative G2 interface with web
parameters NO3-N, NO3, NOx-N and NOx previously browser configuration and internal data logger, NICO
known from NICO, but has now been expanded to in- plus has features that are significantly above the cur-
clude numerous parameters. These include UVT254, rently available devices on the market, in combina-
UVT254n, SAK254, CSBeq, BSBeq, TOCeq, DOCeq, tur- tion with an attractive price.
eCHEM
UVT254n
(referred to 10 mm cuvettes) (referred to 10 mm cuvettes)
SAC254** 1.5...60 1/m 1.5 1/m
CODeq 2.2…90 ppm 2.2 ppm
BODeq 0.7…30 ppm 0.7 ppm
TOCeq 1…35 ppm 1 ppm
DOCeq 1…35 ppm 1 ppm
Accessories
Technische Spezifikationen
Photometer
Measurement light source Xenon flash lamp
technology detector 4 photo diodes + filter
Measurement principle Attenuation
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 20 mm, 50 mm
Fluorometer
Parameters See parameter list
Measurement range See parameter list
Measurement accuracy ± (5 % + 2-fold detection limit)
Turbidity compensation Yes
Data Logger ~ 2 GB
Radiometer
Reaction time T100 20 s
Measurement interval ≥ 10 s
Ethernet (TCP/IP)
eCHEM
Interface digital
RS-485 (Modbus RTU)
Power consumption ≤7W
Power supply 12 – 24 VDC (± 10 %)
Required supervision Typically ≤ 0.5 h/month
Calibration/maintenance interval 24 months
Controller
System compatibility Modbus RTU
Warranty 1 year (EU & USA: 2 years) USA: 2 years
LISA UV
Photometer
14SXXXXX0
Fluorometer
LISA – The innovative SAC254 sensor by TriOS can easily be configured through any standard web
browser on a PC, tablet or Smartphone.
Long-lasting and energy-efficient UV-LED technolo-
gy and a robust design are the outstanding features The optical path length can be adapted to the application
Radiometer
of LISA UV. Like all TriOS sensors LISA uses the at any time by various adapters. An automatic turbidity
unique nanocoated windows combined with com- compensation is carried out via a second measuring
pressed air flushing to achieve long operating times channel.
without cleaning.
Through application-specific correlation LISA UV
The innovative TriOS G2 interface allows quick and can be configured for direct output of BODeq, CODeq,
easy integration of the sensor into existing process TOCeq and UVT.
control systems or external data logger. In addi-
LISA – Cutting-edge measurement technology at
eCHEM
Benefits Applications
• Real-time sensor
• Drinking water
• Without reagents
• Monitoring of UV-disinfection systems
• Optical window with nano coating
• LED technology
SAC254nm* 0-1500 /m 5 /m
CODeq 0-2200 mg/L 8 mg/L
1 mm BODeq 0-700 mg/L 2.5 mg/L
TOCeq 0-880 mg/L 3 mg/L
UVT 3-100 % 98.8 %
SAC254nm* 0-150 /m 0.5 /m
Accessories
Technical Specifications
Photometer
Measure light source 2 LED (254 nm, 530 nm)
ment tech
nology detector Photo diode + filter
Measurement principle Attenuation, Transmission
Optical path 1 mm, 2 mm, 5 mm, 10 mm, 50 mm
Fluorometer
Parameter SAK254, CSBeq, BSBeq, TOCeq, UVT
Measuring range See parameter list
Measurement accuracy 0.2 % FS (Full Scale)
Turbidity compensation at 530 nm
Data logger ~ 2 MB
Radiometer
T100 response time 4s
Measurement interval ≥2s
eCHEM
Ethernet (TCP/IP)
digital
RS-232 or RS-485 (Modbus RTU)
Interface
Ethernet (TCP/IP)
analog
4...20 mA
Power consumption ≤1W
Controller
Power supply 12...24 VDC (± 10 %)
Installation
with SubConn 30 bar ~ 435 psig
Max. pres
with fixed cable 3 bar ~ 43.5 psig
sure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Accessories
VIPER
Photometer
17SXXXXX0
Fluorometer
VIPER measures spectrally resolved attenuation in drinking water. Like every TriOS sensor, VIPER
Radiometer
the wavelength range between 360 nm and 720 nm is equipped with nano-coated optical windows to
and thus allows the detailed determination of several prevent dirt build-up. Additional parameters can
parameters at the same time. 5 selected and energy- be installed later using software, if necessary.
saving LEDs serve as the light source, ensuring VIPER is equipped with the new TriOS G2 interface,
stable measurement data and a long service life. allowing easy and fast sensor configuration via a
VIPER can be used in a wide variety of media, as web browser. Integration into existing process control
it is available in several path lengths and in both systems and external data loggers has never been
stainless steel and titanium. Applications for VIPER easier.
eCHEM
NEW! The TriOS compressed air flushing is now also available for the paths 100 mm, 150 mm and 250 mm!
Advantages Applications
Controller
• Industry
• Food industry
Accessories
Systems
Technical specifications
Photometer
light source 5 LED
Measure
ment tech High-end miniature spectrometer, 256 channels
nology detector
360 to 750 nm, 2.2 nm/pixel
Measurement principle Attenuation
Fluorometer
Optical path 10 mm, 50 mm, 100 mm, 150 mm, 250 mm
SAC436
Pt-Co color scale (APHA/Hazen) (390 nm, 455 nm)
Parameter Colouring based on DIN EN ISO 7887-C
(410 nm, 436 nm, 525 nm, 620 nm)
Cr-Co color scale (380 nm, 413 nm)
Radiometer
Measuring range 0.01...2.5 AU (absorption units)
Measurement accuracy < 0.2 %
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min
eCHEM
Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035)
Dimensions (L x Ø) 495 mm x 48 mm (with 50 mm path) ~ 19.5˝ x 1.9˝ (with 50 mm path)
stainless steel ~ 2.4 kg (with 50 mm path) ~ 5.3 lbs (with 50 mm path)
Weight
titanium ~ 1.3 kg (with 50 mm path) ~ 2.9 lbs (with 50 mm path)
Ethernet (TCP/IP)
Controller
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤3W
Power supply 12...24 VDC (± 10 %)
Colour Measurement
Photometer
Fluorometer
Radiometer
eCHEM
VIPER is an in-situ VIS spectrophotometer to determine the colour of liquids. In addition to the hyperspectral
recording of spectra (2.2 nm/pixel), various colour numbers can be determined. This enables standardized,
safe and objective measurements. Time-consuming and expensive sampling is eliminated by in-situ
measurements. What's more, variations over a whole day can be recorded.
Controller
Depending on the customer's request, SACs in the entire wavelength range (such as SAC525, SAC620) can be
determined, or individual opacity adjustments can be made.
The Pt-Co colour number records the range from colourless (<1) to light yellow to orange (500). The colour
number is defined via a standard solution of hexachloroplatinate in acidic salt water and specified in mg/L Pt.
The Pt-Co colour number is calculated using the turbidity corrected attenuation at 455 nm or 390 nm.
Systems
Colouring
Photometer
VIPER enables hyperspectral measure-
ments of the colour of each liquid.
This also allows the differentiation of co-
lours that are perceived immediately, but
consist of different colour mixes.
Fluorometer
The diagram on the left shows examples
from the beverage industry.
Radiometer
Subsequent calculation of colour numbers
is also possible thanks to the storage of
spectra. VIPER therefore enables several
colour numbers to be simultaneously
calculated from a spectrum. In addition
to the above colour numbers, the device
can determine the Cr-Co colour number
eCHEM
(Russian grade) in accordance with
GOST 3351-74, which is interesting for
the Russian market. Please contact us
for any special applications. We will be
happy to help.
Controller
Dry Standards
Accessories
Systems
LISA color
Photometer
5XSXXXXX0
Fluorometer
Colorimetry – LISA enables reliable low-cost colour Equipped with our innovative G2 interface with a web
measurements. The LISA color uses two different browser configuration, internal data logger, flexible
LEDs for long-term stable measurement of the protocols and data outputs, the LISA color possess-
Radiometer
SAC or color at different wavelengths. The second es equipment attributes that are significantly greater
channel is used for turbidity/background correction. than the devices currently available on the market
The cutting-edge device platform, used in all other
The unified platform of all TriOS photometers also
TriOS photometers, enables optical path lengths
facilitates a standardized spare parts and consum-
of 50, 100, 150, and 250 mm, so that almost any
ables system, which means the broad range of our
application can be easily implemented.
device accessories can be implemented. The cut-
With the optional titanium housing, the LISA color ting-edge G2 interface also enables quick integration
can also be used for applications in aggressive into third-party systems.
eCHEM
NEW! The TriOS pressure cleaning is now available for the path lengths 100 mm, 150 mm and 250 mm!
Controller
Benefits Applications
Technical Specifications
Photometer
Measurement Light source 2 LEDs
technology Detector Photodiode
Measurement principle Attenuation, transmission
Optical path 50 mm, 100 mm, 150 mm, 250 mm
Fluorometer
Color (based on DIN EN ISO 7887 (410 nm, 436nm, 525 nm, 620 nm)
Parameters
Pt-Co color number (APHA/Hazen) (390 nm or 455 nm)
Cr-Co color number (380 nm or 413 nm)
Measurement range See parameter list p.26
Measurement accuracy 0.5 %
Radiometer
Turbidity compensation yes, 740 nm
Data logger ~ 2 MB
Reaction time T100 4s
Measurement interval ≥2s
eCHEM
stainless steel ~ 2.4 kg (for 50-mm path) ~ 5.3 lbs (for 50-mm path)
Weight
titanium ~ 1.3 kg (for 50-mm path) ~ 2.9 lbs (for 50-mm path)
Ethernet (TCP/IP)
digital
RS-232 or RS-485 (Modbus RTU)
Interface
Ethernet (TCP/IP)
analog
4...20 mA
Controller
Power consumption ≤1W
Power supply 12...24 VDC (± 10 %)
Measurement range
Measurement range
Parameters Unit
50 mm 100 mm 150 mm 250 mm
SAC 436 nm 1/m 0.1...30 0.05...15 0.03...10 0.02...6
SAC 525 nm 1/m 0.1...30 0.05...15 0.03...10 0.02...6
Fluorometer
150 mm 50 mm
Controller
Dry Standards
Accessories
Systems
27
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Fluorometer // Sensor
28
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Fluorometer
Sensor // Fluorometer
29
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Fluorometer // enviroFlu
enviroFlu
Photometer
30SXXXXX0
Fluorometer
probes for measuring oil-in-water. The measuring The devices can be used stationary in manholes, in
principle of UV fluorescence used is far more the flow or in pipelines, as well as portable, using
sensitive than the conventionally used infrared an optional hand-held measuring device. A new type
scattering or absorption methods. This makes it of coating reduces soiling of the optical measuring
possible to determine even the smallest traces of windows and thus reduces the required maintenance
PAHs, e.g. in drinking water, but also in cooling water to a minimum.
condensates. The field of application ranges from
petrochemistry, leakage detection in cooling and
eCHEM
Technical specifications
Photometer
Measurement Light source Xenon flash lamp + filter (254 nm)
technology Detector Photodiode + filter (360 nm)
Measurement principle Fluorescence
Fluorometer
enviroFlu HC PAH: 0...50 ppb, 0...500 ppb,
Measure (MB) 500 Oil: 0...1.5 ppm, 0...15 ppm typ.
ment enviroFlu HC PAH: 0...500 ppb, 0...5000 ppb
range (MB) 5000 Oil: 0...15 ppm, 0...150 ppm typ.
enviroFlu BT 0...1000 ppb, 0...10 000 ppb
enviroFlu HC (MB) 500 0.3 ppb
Detection limit
Radiometer
enviroFlu HC (MB) 5000 0.5 ppb
Measurement accuracy ± 5 % FS*
Reproducibility ≤ 0.5 % FS*
Turbidity compensation No (only possible via TTurb on the TriBox3)
Data logger no
Reaction time T100 ≤ 10 s
eCHEM
Measurement interval ≥5s
Controller
Analog: 4...20 mA, 0...5 V
Power consumption ≤ 3.5 W
Power supply 12...24 VDC (± 10 %)
33
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Fluorometer // nanoFlu
nanoFlu
Photometer
32SXXXXX0
Fluorometer
Miniature fluorometer
nanoFlu fluorometers are low-priced, submersib- as well as in drinking and wastewater treatment sys-
Radiometer
le miniaturized fluorometers for the highly precise, tems. Internal reference signals of the high perfor-
selective measurement of cdom (coloured dissolved mance LEDs used for fluorescence excitation com-
organic matter, yellow substances), chlorophyll a, pensate ageing effects and temperature influences.
phycocyanin in cyanobacteria, rhodamine or fluore-
The nanoFlu features the new TriOS G2 interface,
scein. Long-term stability of measurements is ensu-
allowing fast and easy configuration of sensors
red by the combination of low power consumption
by using a web browser. Integration into existing
and innovative coating of the optical window, as an
process control systems and external data loggers
energy efficient and environmentally friendly antifou-
has never been easier.
ling solution. The devices can be used in diverse ap-
eCHEM
Benefits Applications
• Low costs
• FlowCell
• SolidCAL
Parameter list
Accessories
Technical Specifications
Photometer
Measurement Light source LED
technology Detector Photodiode
Measurement principle Fluorescence
Fluorometer
Measurement range 0...200 µg/L or 0...500 µg/L
Measurement accuracy ±5%
Turbidity compensation no
Data logger no
Reaction time T100 6s
Radiometer
Measurement interval 3s
Stainless steel (1.4571/1.4404) or
Housing material titanium (3.7035) or
POM
Dimensions (L x Ø) 171 mm x 36 mm
stainless steel 0.5 kg
Weight
titanium 0.4 kg
eCHEM
POM 0.27 kg
Ethernet (TCP/IP)
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power con typical <1W
sumption with network < 1.6 W
Controller
Power supply 12...24 VDC (± 10 %)
Installation
with SubConn 30 bars
Max. pressure with fixed cable 3 bars
in FlowCell 1 bar, 2...4 L/min
Protection type IP68
Accessories
matrixFlu VIS
Photometer
34S10XXXX
Fluorometer
Our high-end matrixFlu VIS fluorometer combines sured values is increased by an internal temperature
multiple excitation and detection wavelengths for flu- correction.
orescence measurements in a single device with a
Equipped with our innovative G2 interface with web
highly compact design. The special optical arrange-
Radiometer
Benefits
samples
• Real-time sensor
• Without reagents
• Optical window with nano coating
Dry Standards
Applications
• Surface water
• Bathing lakes
• Drinking water production and treatment
• Raw water treatment
Detail of design for 4x4 wavelengths
• Environmental monitoring
Accessories
Em
Ex 460 682 655 850
Technical Specifications
Photometer
Measure light source 3 LED (375 nm/470 nm/590 nm)
ment tech
nology detector 4 photo diodes with filter
Measurement principle Fluorescence
Fluorometer
Chlorophyll a [µg/L]
Parameter Phycocyanin [µg/L]
cdom [µg/L]
Measuring range 0...200 µg/L 0...200 ppb
Measurement accuracy 5%
Turbidity compensation Yes
Radiometer
Data logger ~ 10 MB
T100 response time 12 s
Measurement interval 6s
eCHEM
Weight
titanium ~ 0.5 kg ~ 1.1 lbs
Ethernet (TCP/IP)
Interface digital
RS-232 oder RS-485 (Modbus RTU, OGC PUCK)
Power consumption ≤ 1.8 W
Power supply 12...24 VDC (± 10 %)
Controller
Maintenance effort ≤ 0.5 h/month (typical)
Calibration/maintenance
24 months
interval
System compatibility Modbus RTU, OGC PUCK
Warranty 1 year (EU: 2 years) US: 2 years
Dry Standards
Installation
with SubConn 30 bar ~ 435 psig
Max. pres
with fixed
sure 3 bar ~ 43.5 psig
cable
Protection type IP68 NEMA 6P
microFlu V2
Photometer
37SX0XX1X
Fluorometer
Radiometer
microFlu V2 fluorometers are submersible miniature fluorometers for highly precise and selective measurement
of tryptophan, cdom, blue-green algae or chlorophyll. The combination of low power consumption and
innovative coating of the measurement windows as an energy and environmentally neutral antifouling solution
ensures long-term stability of the measurements. The instruments can be used in a wide range of applications
for monitoring seawater, river water, drinking water and wastewater. Internal reference measurements of the
high-power LED used for fluorescence excitation compensate for aging effects and temperature influences.
microFlu V2 is equipped with a RS-485 interface, which enables allows easy and fast sensor configuration via
Modbus. Integration into existing process control systems and external data loggers has never been easier.
eCHEM
Advantages Applications
Technical specifications
Photometer
Measurement Light source LED + Filter
technology Detector Photodiode + Filter
Measurement principle Fluorescence
Chlorophyll a [µg/L]
Phycocyanin [µg/L]
Fluorometer
Parameters
cdom [µg/L]
Tryptophan [µg/L]
Measurement range See parameter list
Detection limits See parameter list
Measurement accuracy +/- (5 % + Detection limit)
Radiometer
Turbidity compensation No
Data logger No
Reaction time T90 6 s (default)
Smallest measuring interval 3 s (default)
eCHEM
analog 0–5V
0 – 10 V
typical max. 0.6 W
Power con with activated
max. 1.1 W
sumption analog interface
Power-Down max. 70 mW
Controller
Power supply 12 – 24 VDC (± 10 %)
microFlu V2 HC
Photometer
37S80XX13
Fluorometer
Radiometer
microFlu V2 HC is a new immersion probe for measuring oil in water. The measuring principle of UV
fluorescence used is many times more sensitive and specific than the conventionally used infrared scattering
or absorption methods. This makes it possible to determine even the smallest traces of PAHs, e.g. in drinking
water, but also in cooling water condensates. The field of application ranges from petrochemistry, leakage
detection in cooling and waste water streams to environmental monitoring. The instruments can be used
stationary in manholes or in flow-through, as well as in pipelines. A nano-coating reduces the contamination
of the optical measuring windows and thus reduces the required maintenance to a minimum.
microFlu V2 HC is equipped with an RS-485 interface that allows easy and fast sensor configuration via
eCHEM
Modbus and also has an analog interface. Integration with existing process control systems and external data
loggers has never been easier.
Advantages Applications
Technical specifications
Accessories
Photometer
PAH: 0...5000 ppb
Measurement range
Oil: 0...150 ppm typ.
PAH: 5 ppb
Detection limits
Oil: 0.15 ppm typ.
Measurement accuracy ±10 % FS
Turbidity compensation No
Fluorometer
Data logger No
Reaction time T90 6s
Smallest measuring interval 3s
Radiometer
Interface
analog 0–5V
0 – 10 V
typical max. 0.6 W
Power con with activated
max. 1.1 W
sumption analog interface
Power-Down max. 70 mW
eCHEM
Power supply 12 – 24 VDC (± 10 %)
Controller
Dimensions (L x Ø) ca. 162 mm x 48 mm ~ 6.4“ x 1.9“
VA ~ 650 g ~ 1.4 lbs
Weight
TI ~ 510 g ~ 1.1 lbs
Dry Standards
Max. pressure with fixed cable 3 bar ~ 43.5 psig
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P
42
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Radiometer
Sensor // Radiometer
43
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Radiometer // RAMSES
RAMSES
Photometer
40SXXX010
Fluorometer
Spectral imaging radiometer to measure radiance or irradiance in UV, VIS and UV/VIS
RAMSES radiometers are spectral imaging radiometers to measure radiance, irradiance, or scalar irradiance
in the UV, VIS and UV/VIS ranges. Thanks to their ultra small size and weight as well as very low power
Radiometer
consumption, they are especially suitable for hand-held and autonomous applications. RAMSES radiome-
ters combine precision hyperspectral light measurements with a maximum of flexibility. The modular system
increases cost-effectiveness, while the many accessories and special solutions enable a wide range of appli-
cations such as installation on ships, handheld usage or autonomous measurements in remote places, like
the Arctic or Antarctica.
Benefits Applications
eCHEM
• Color measurements
• Climate research
Dry Standards
Accessories
Technical Specifications
Photometer
Measurement High-end miniature spectrometer
Detector
technology 256 Channels
Measurement Principle Radiance or irradiance
Fluorometer
Measuring range See parameter list p.46
Measurement accuracy See parameter list p.46
T100 response time ≤ 10 s (burst mode)
Measurement interval ≤ 8 s (burst mode)
Radiometer
Dimensions without IP Module, without
ARC 300 mm x 48 mm ARC ~ 11.8” x 1.9”
SubConn Connector (L x Ø)
ASC 245 mm x 48 mm ASC ~ 9.6” x 1.9”
Dimensions with IP Modul, without ACC 284 mm x 48.5 mm ACC ~ 11.2” x 1.9”
connector ARC 322 mm x 48.5 mm ARC ~ 12.7” x 1.9”
Weight Titanium 1.25 kg ~ 2.8 lbs
eCHEM
Data logger -
Power consumption ≤ 0.85 W
Power supply 8...12 VDC (± 3 %)
Controller
Warranty 1 Year (EU & USA : 2 Years)
*) Specifications of Carl ZEISS AG, Germany **) Integration time ***) Depends on wavelength range ****) Noise-equivalent irradiance
46
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
RAMSES G2 // Radiometer
RAMSES G2
Photometer
40SXXX010
Fluorometer
Spectral imaging radiometer to measure radiance or irradiance in UV, VIS and UV/VIS
RAMSES radiometers are spectral imaging radiometers to measure radiance, irradiance, or scalar irradiance
in the UV, VIS and UV/VIS ranges. Thanks to their ultra small size and weight as well as very low power
consumption, they are especially suitable for hand-held and autonomous applications. RAMSES radiome-
ters combine precision hyperspectral light measurements with a maximum of flexibility. The modular system
Radiometer
increases cost-effectiveness, while many accessories and special solutions enable a wide range of applica-
tions such as installation on ships, handheld usage or autonomous measurements in remote places, like the
Arctic or Antarctica.
By implementing the G2 extension module, the RAMSES radiometry series now also features the innovative
G2 Interface and can now easily be configured by using a web-browser. The internal data logger with 2 GB
storage and the comparably low power consumption provides the opportunity for a self-sufficient measure-
ment operation without a separate controller. The addition of the Modbus RTU protocol to the interface sim-
eCHEM
plifies the integration into existing PLCs and external data loggers. Additional to radiance and irradiance, the
parameters inclination, pressure and temperature can be retrieved.
Controller
Dry Standards
Accessories
Benefits Applications
Technical Specifications
Dimensions with IP Modul, without ACC 284 mm x 48.5 mm ACC ~ 11.2” x 1.9”
connector ARC 322 mm x 48.5 mm ARC ~ 12.7” x 1.9”
Weight Titanium 1.25 kg ~ 2.8 lbs
RAMSES G2 // Radiometer
pixel]
Wavelength accuracy* 0.2 0.2 0.3 0.3 0.3
Usable channels 100 200 190 190 190
*) Specifications of Carl ZEISS AG, Germany **) Integration time ***) Depends on wavelength range ****) Noise-equivalent irradiance
49
50
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
eCHEM
Sensor // eCHEM
51
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
eCHEM // TpH
80S1000X0
Fluorometer
Robust digital pH sensor for operation on TriBox controllers and HS100 DIN G2 rail module. Digital communication
ensures safe and trouble-free signal transmission from the sensor to the controller. The high-quality gel pH electro-
de has a hole diaphragm and is insensitive to dirt, making the sensor ideal for wastewater applications.
Radiometer
Benefits Applications
• High-quality combination electrode with hole di- • Water and wastewater treatment
aphragm and polymerised solid electrolyte
• Coagulation and flocculation
• Low maintenance
• Process monitoring and control
• Plug and play with TriBox controller
• Acid/base neutralization systems
eCHEM
Accessories
Technical Specifications
pH 0...14 pH
measuring range
Temperature 0...+65 °C
pH 0.01 pH
resolution
Temperature 0.1 °C
pH ± 0,06 pH
precision
Temperature ± 0.5 °C
Accessories
pH1 ± 0.05 pH
Intrinsic error pH7 ± 0.05 pH
pH13 ± 0.35 pH
Linearity measurement error ± 0.1 pH
The sensor complies with DIN EN 60746-2:2003-09 and the electrodes with BS 2586:1979.
Systems
Photometer
pH1 ± 0.1 pH
Repeatability pH7 ± 0.05 pH
pH13 ± 0.1 pH
Output signal pH7 ± 0.025 pH
fluctuation pH4 ± 0.05 pH
Warm-up time < 5 min
Fluorometer
Drift Short-term drift 24 h ≤ 0.03 pH
Long-term drift 1 week ≤ 0.05 pH
T10 ascending <2s
10% time and T10 falling <2s
90% time T90 ascending ≤5s
Radiometer
T90 falling ≤5s
Temperature compensation Pt1000
Measurement interval 2s
eCHEM
Interface RS-485, Modbus RTU
Power consumption 0.2 W
Power supply 12...24 VDC (± 10 %)
Connection 8-pin M12 plug
Sensor cable 2 m and 10 m
Controller
Required supervision Typically ≤ 0.5 h/month
Calibration / maintenance interval Typically 4 weeks
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics; wearing parts
Warranty
are excluded from the warranty
80S2000X0
Fluorometer
Robust, digital differential pH probe for operation with TriBox controllers and HS100 top-hat rail module. The
reference system of the pH electrode is separated from the measuring medium due to the closed design. This
Radiometer
rules out electrode poisoning. A salt bridge that is insensitive to dirt reduces the amount of cleaning required
and prevents dilution of the electrolyte. As a result, the probe achieves a particularly long service life even in
heavily contaminated media.TpH-D is available with a cable length of 10 m or 2 m.
Advantages Applications
Technical specifications
Accuracy
Temperature ± 0.5 °C
pH1 ± 0.05 pH
Intrinsic error pH7 ± 0.05 pH
pH13 ± 0.35 pH
The sensor complies with DIN EN 60746-2:2003-09 and the electrodes with BS 2586:1979.
Systems
Photometer
Linearity measurement error ± 0.1 pH
pH1 ± 0.1 pH
Repeatability pH7 ± 0.05 pH
pH13 ± 0.1 pH
Output signal pH7 ± 0.025 pH
fluctuation pH4 ± 0.05 pH
Fluorometer
Warm-up time < 5 min
Drift Short-term drift 24 h < 0.03 pH
Long-term drift 1 week < 0.05 pH
T10 ascending <2s
10% time and T10 falling <2s
Radiometer
90% time T90 ascending ≤5s
T90 falling ≤5s
Temperature compensation Pt1000
Measurement interval 2s
eCHEM
Weight 180 g ~ 0.4 lbs
Interface RS-485, Modbus RTU
Power consumption 0.2 W
Controller
Sensor cable 2 m and 10 m
81SXX00XX
Fluorometer
The TTurb is a digital sensor for optical turbidity measurement using the 90° IR scattered light method. De-
pending on the sensor design it can be used in pure water up to 100 FNU as well as in raw water, waste water
and process water up to 1000 FNU. TTurb is available with different cable lengths (10 m or 2 m) as well as
Radiometer
in different versions.
As an immersion sensor, the TTurb can be used directly in the measuring medium, but is also available in the
FlowCell-optimized version directly with a flow cell for bypass applications. In addition, it is possible to obtain
the TTurb directly in a set with the dry-standard TTurbCAL. This standard is always directly adapted to each
individual instrument and thus enables precise function tests directly on site, without any reagents.
eCHEM
Benefits Applications
Controller
• Fittings: FlowCell
• TTurbCAL
Systems
Technical Specifications
Photometer
LED light source
Measurement technology
Photodiode detector
Measurement principle Nephelometry
Fluorometer
Measuring range 0...100, 0...400, 0...1000 FNU
Measurement accuracy ± (5 % + 0.5)
0.5 FNU for TTurb 100
Detection limit 2 FNU for TTurb 400
2 FNU for TTurb 1000
Measurement wavelength 860 nm, FWHM 30 nm
Radiometer
Reaction time T100 6s
Measurement interval ≥3s
eCHEM
Ethernet (TCP/IP)
Interface
RS-485 (Modbus RTU)
typically < 0.9 W
Power consumption
with network < 1.5 W
Power Supply 12...24 VDC (± 10 %)
Connection 8-pin M12 plug
Controller
Required supervision ≤ 0.5 h/month typically
Calibration/
24 months
maintenance interval
System compatibility Modbus RTU
1 year (EU&US: 2 years) on electronics;
Warranty
wearing parts are excluded from the warranty
Dry Standards
with fixed cable 3 bar ~ 43.5 psig
Max. pressure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P
Conductivity Sensor
Photometer
90S4301X0
Fluorometer
Radiometer
Digital sensor to measure conductive conductivity especially in pure media, for operation on TriBox con-
trollers and HS100 DIN G2 rail module. The digital technology ensures secure and interference-free signal
transmission from the sensor to the controller.
eCHEM
Benefits Applications
Technical Specifications
Photometer
Measurement technology Conductivity
Measurement principle Conductivity with two graphite electrodes
Parameters Conductivity
Fluorometer
Measurement range 0.00 µS… 20000 µS
±0.5 µS at 20 µS
± 5 µS at 200 µS
Measurement accuracy
± 50 µS at 2000 µS
± 500 µS at 20000 µS
Response time T90 < 60s
Radiometer
Temperature compensation Via NTC
eCHEM
Maintenance interval 2 years
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty
Controller
Calibration method One-point calibration with standard measuring solution
Dry Standards
Accessories
Systems
Conductivity Inductive
Photometer
90S4401X0
Fluorometer
Radiometer
eCHEM
The inductive conductivity sensor has 2 toroidal coils which are housed in a plastic casing and therefore do
not come into contact with the surrounding solution. For this reason, it is physically impossible for the sensor
surface to become soiled, coated or contaminated.
Since the inductive conductivity sensor does not determine the conductivity via electrodes, but via electrical
fields, no polarization effects occur. Thus the sensor provides more accurate measurement results, especially
for measurement media with high conductivities.
Controller
Benefits
sensor surface
• No polarization effects
• Low maintenance requirement
Accessories
Systems
Technical specifications
Photometer
Measurement technology Change of inductance
Measurement principle Change of inductance with two toroidal coils
Parameter Conductivity
Fluorometer
Measuring range 0.5 mS/cm – 2000 mS/cm
Measurement accuracy ± (2% + 20 μS/cm)
Drift 0.1 % / Year
Turbidity compensation No
Temperature compensation Via NTC
Radiometer
Data Logger No
Response time T90, depending on equilibrium
Measurement interval 10 seconds
eCHEM
Interface RS-485 Modbus RTU (Baud rate = 9600)
Power consumption < 75 mW
Power supply 7 ‒ 40 VDC
Connection 8-pin M12 connector
Maintenance effort ≤ 0.5 h/month typical
Controller
Maintenance interval 24 Months
Two-point calibration in air and with standard measuring solution during
Calibration method
initial installation, followed by validation
System compatibility Modbus RTU
Warranty 1 year, EU & USA: 2 years
Dry Standards
90S53X1X0
Fluorometer
Radiometer
The oxygen sensor uses luminescence-based optical measurement technology and measures reliably and
precisely. The low maintenance and small amount of consumable materials needed by the sensor provide
immediate returns on investment. Only the membrane cap must be replaced every two years. The sensor
can also be used in applications with a very weak water flow. The oxygen sensor is available with a 10-meter
or a 2-meter cable.
eCHEM
Benefits Applications
• Low operation costs thanks to low maintenance • Measurement of dissolved oxygen in surface
(no electrolyte replacement)
Controller
Technical Specifications
Photometer
Measurement principle Luminescence
Fluorometer
0...200 %
± 0.1 mg/L
Measurement accuracy ± 0.1 ppm
±1%
Resolution 0.01
Reaction time 90% of the value in less than 60 seconds
Measurement interval >5s
Radiometer
Inflow velocity No movement necessary
Temperature compensation Via NTC (compensation active for temperatures below 0 °C)
Measurement range (tem
0...+50 °C
perature)
Resolution (temperature) 0.01 °C
Accuracy (temperature) 0.5 °C
No cross-sensitivity with: pH 1...14 ; CO2, H2S, SO2
eCHEM
Membrane cap Cross-sensitivity with organic solvents such as acetone, toluene, chloro-
form dichloromethane (methylene chloride) or chlorine gas
Standard version with passivated stainless steel (316L) housing, cap and
screws; For seawater applications with titanium housing, cap and screws
Material Cable: polyurethane casing; Cable grommet: polyamide
Patch with active substance (black) - membrane: silicon for optical insu-
Controller
lation
Dimensions (L x Ø) 146 mm x 25 mm ~ 5.7˝ x 1˝
stainless steel ~ 450 g ~ 1 lbs
Weight
titanium ~ 300 g ~ 0.7 lbs
Calibration/maintenance
2 years
interval
1 year (EU & US: 2 years) on electronics; wear parts are excluded from the
Warranty
warranty
Accessories
90S21000X
Fluorometer
Radiometer
The chlorine sensor from the eCHEM sensors product range is an electrochemical sensor for measuring the
chlorine concentration in water. This sensor detects free chlorine from inorganic chlorine products (chlorine
gas, hypochlorite, etc.). The measuring method has a reduced pH dependency, so that pH fluctuations only
have a limited impact on the measurement signal. pH value increases only lead to an approximately 10%
reduction of the measuring signal per pH unit.
eCHEM
Benefits Applications
• Stable signals even with fluctuating pH values • Swimming pools, drinking water, seawater
• Abrasive particles are tolerated
Controller
Technical Specifications
Photometer
Measurement technology Membrane-covered, amperometric potentiostatic 3-electrode system
Measurement principle Amperometry
Fluorometer
Measurement range 0...2 mg/L, 0...20 mg/L
Radiometer
Response time T90: approx. 2 min
eCHEM
Housing material Micro-porous hydrophilic membrane, UPVC, stainless steel 1.4571
Dimensions (L x Ø) Approx. 205 mm x approx. 25 mm ~ 8.1” x 1”
Controller
Maintenance interval typically once per week
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty
90SX20000
Fluorometer
Radiometer
The chlorine dioxide sensor from the eCHEM sensors product range is an electrochemical sensor for meas-
uring the chlorine dioxide concentration in water. The range of application of the sensor covers almost all wa-
eCHEM
ter qualities and treatments (e.g. bottle washing machine, CIP system, rinser). It can also be used in seawa-
ter. Thanks to a special membrane system, the sensor is particularly resistant to chemicals and surfactants.
Benefits Applications
Controller
Technical Specifications
Photometer
Measurement technology Membrane-covered, amperometric 2-electrode system
Measurement principle Amperometry
Fluorometer
Measurement range 0...2 mg/L, 0...20 mg/L
Measuring range 2 mg/L:
Radiometer
Response time T90: approx. 1 min
eCHEM
Housing material Micro-porous hydrophilic membrane, UPVC, stainless steel 1.4571
Dimensions (L x Ø) Approx. 205 mm x approx. 25 mm ~ 8.1” x 1”
Controller
typically once a week measuring signal check,
Maintenance interval
membrane cap change & electrolyte change depending on application
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty
90SX30000
Fluorometer
Radiometer
The chlorine sensor from the eCHEM sensor product range is an electrochemical sensor for measuring the
chlorine concentration in water. The sensor measures the concentration of total chlorine in a sample created
by adding inorganic chlorine products (e.g. chlorine gas, sodium hypochlorite solution, calicium hypochlorite
solution). The measuring method has a reduced pH dependency, so that pH value fluctuations only have a
minor influence on the measuring signal. By regularly replacing the electrolyte and the membrane cap, the
sensor performance can be guaranteed and ensured over a longer period of time.
Advantages
eCHEM
Applications
• Stable signals even with variable pH values • Swimming pools, drinking water, seawater,
brine water (15% NaCl)
• Surfactants are partially tolerated
Accessories
Technical specifications
Dry Standards
Photometer
Measuring range 2 mg/L: 0.001 mg/L
Resolution
Measuring range 20 mg/L: 0.01 mg/L
Response time T90: approx. 3 minutes (brine water approx. 5 minutes)
Running-in time Approx. 2 hours for initial start-up
Slope drift approx. -1 % per month
Automatically, through an integrated temperature sensor, tempera-
Temperature compensation
ture jumps are to be avoided
Fluorometer
pH range pH 4 - pH 12, with reduced pH dependence
Conductivity 10 µS/cm - 200 µS/cm (brine water)
Zero point determination Not necessary
On the unit by analytical chlorine determination, DPD-4 method
Slope calibration
(DPD-1 + DPD-3)
ClO2: factor 1; O3: factor 1.3;
Radiometer
Cross-sensitivities Corrosion inhibitors and water hardness stabilisers can cause meas-
urement errors.
Absence of the disinfectant Max. 24 hours
eCHEM
Weight 1.1 kg
Controller
Maintenance effort Depending on the water quality, the membrane cap and the electro-
lyte should be replaced once a year
System compatibility Modbus RTU
1 year (EU & USA: 2 years) on electronics;
Warranty
Wear parts are excluded from the warranty
* After calibration at repeat conditions (25 °C, pH 7.2 in drinking water) from full scale value
** Electronics is completely electrically isolated; digital internal measured value processing
Systems
70
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Controller
Sensor // Controller
71
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
COntroller // TriBox3
TriBox3
Photometer
10C000000
Fluorometer
built-in valve allows the use of a compressed air purge vices. Low power consumption, a robust aluminium
for the sensors. In addition, the TriBox3 offers various housing and a range of interfaces make the TriBox3
interfaces, including an IEEE 802.3 Ethernet interface, ideal for all applications in environmental monitoring,
an IEEE 802.11 b/g/n interface, a USB connection and drinking water, waste water treatment plants and many
6 analogue outputs (4...20 mA). An integrated relay other areas.
Advantages • WiFi for communication
Technical specifications
Controller
Power supply
Voltage supply 100...240 VAC, 50...60 Hz, 12...24 VDC (± 5%)
Power consumption Type: 6 W, max: 50 W
Protection class 1
Overvoltage category II
Dry Standards
Sensor interfaces
Connection 4 M12 industrial connectors for TriOS sensors
Standard RS-232, RS-485
Protocol Modbus-RTU, TriOS
Modbus RTU
Server RTU yes (on each sensor connector)
Accessories
Photometer
Network/USB
Standard Ethernet, WiFi based on IEEE 802.11b/g/n
Connection 1 RJ-45 integrated WiFi antenna (for TriBox3 with WiFi)
Protocol TCP/IP, Modbus TCP, VNC
Web interface no
USB USB 2.0 (Host), USB-A socket
Fluorometer
Analog interfaces
Analog Output 6 analogue outputs, configurable: 4...20 mA
Load max. 500 Ω
Connection terminals 1.5 mm² 16 AWG
Error indicator 0 mA
Radiometer
Switch input/output
Trigger for global measurement (galvanically isolated),
Control voltage: 12...24 VDC (± 5%)
Measurement trigger Control voltage: 12...24 VDC (± 5%)
Connection terminal: 1.5 mm² (AWG
Connection terminal: AWG 16
16)
Control voltage no
Relay outputs
eCHEM
Electrical specification 1 x relay changeover contact (SPDT) / 250 VAC, 2 A / 30 VDC, 2 A
Connection terminals max. 2.5 mm² max. 14 AWG
Display
Controller
Display 7” capacitive touch-display (800x480 pixels)
LED 5 status LEDs
Data Storage
Storage medium internal 2 GB microSD card, direct logging to USB stick possible.
Data Export via USB 2.0 Host
Mechanical system
Dimensions (width x
280 x 170 x 94 mm ~ 11” x 6.7” x 3.7”
height x depth)
Weight 3.7 kg ~ 8.2 lbs
Materials Housing: aluminium die-cast alloy, front panel: acrylic glass (PMMA)
Systems
TriBox mini
Photometer
20C000000
Fluorometer
Benefits
20C100000
Instead of WiFi, the TriBox mini NET has an Ethernet connection via the right port.
Dry Standards
Technical Specifications
Server RTU no
Client RTU yes (on each sensor connector)
Parameters Adjustable (default: 9600-8-N-1)
Systems
Photometer
TB mini WiFi based on IEEE 802.11b/g/n
Standard
TB mini NET Ethernet based on IEEE 802.3i
TB mini Built-in WiFi antenna
Connection
TB mini NET COM2 sensor interface (right) with M12RJ45 cable
Protocol TCP/IP
Web interface yes
Fluorometer
USB no
Radiometer
Measurement trigger no
12 VDC (only for TriOS accessories) 12 VDC (only for TriOS accessories),
Control voltage
terminal: max. 2.5 mm2 terminal: max. 14 AWG
eCHEM
Valve Optional: external connection possible
Controller
Data export
TB mini NET via Ethernet (compressed tar file)
Dry Standards
IP65 (the network cable has a lower NEMA 4X (the network cable has a
Protection type
protection class) lower protection class)
Dimensions (width x
150 x 139 x 80 mm ~ 5.9” x 5.5” x 3.2”
height x depth)
Weight 1.6 kg ~ 3.5 lbs
Housing: Aluminium die-cast alloy
Materials
Front panel: acrylic glass (PMMA)
Accessories
Systems
HS100
Photometer
11C300000
Fluorometer
Benefits
Technical Specifications
Photometer
Energy supply
Voltage supply 24 VDC (± 10 %)
Power consumption typical: 2.5 W
Sensor interfaces
Fluorometer
Connection 1x M12 plug for TriOS G2 sensors
Standard RS-485
Protocol Modbus RTU
Analog interfaces No
Switch input/output No
Relay outputs No
Radiometer
Compressed air cleaning No
Modbus RTU
Client RTU Yes (connected to the sensor)
Parameter Adjustable (default: 9600-8-N-1)
Modbus TCP
Server TCP Yes
eCHEM
TCP port Adjustable (default: 502)
Network/USB
Standard Ethernet, WiFi IEEE 802.11b/g/n
Connection 2 x RJ-45, external WiFi antenna (SMA)
Protocol TCP/IP, Modbus TCP
Web Interface Yes
Controller
USB No
Data storage No
Display
Display No
LED 4 x status LED
Dry Standards
Ambient
Operating temperature 0...+40 °C ~ +32 °F to +104 °F
Storage temperature -20...+70 °C ~ -4 °F to +158 °F
Relative air humidity 0...95 % (non-condensing)
Protection type IP20 NEMA 1
Mechanics
Accessories
78
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Dry Standards
Sensor // Dry Standards
79
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Dry Standards // SolidCAL
SolidCAL
Photometer
20AXX000X
Fluorometer
Radiometer
FieldCAL
Photometer
20A210003
Fluorometer
RAMSES radiometers in the field. Thanks to
the special design, radiance (ARC), as well
as irradiance (ACC) sensors can be che-
cked. An adapter used for radiance sensors
is included in the set. Small dimensions and a
sturdy transport box make FieldCAL a useful tool
for light measurements in the field.
Radiometer
Benefits
• High stability
• Battery-powered
• Small size
• Easy to use
eCHEM
• For irradiance and radiance sensors
Technical Specifications
Controller
Light source White LED with spherical diffuser
Stability Type Better than 1% after 1 minute
Battery 4 AA (not rechargeable)
Operating time Type 50 hours per battery charge
Material POM, seawater-resistant plastic
Dry Standards
50 mm x 140 mm
~ 2" x 5.5"
Dimensions (ØxL) 50/60 mm x 182 mm (with ACC
~ 2/2.4" x 7.2" (with ACC Adapter)
Adapter)
Accessories
Systems
DryCAL
Photometer
20A100008
Fluorometer
Radiometer
DryCAL enables high-precision validation of the corresponding enviroFlu sensor. Every DryCAL corresponds
precisely to a certain sensor and is calibrated to its specific properties, which significantly increases the
precision of the calibration.
The DryCAL is sold as a set with two dry calibration standards.
eCHEM
TTurbCAL
20A100007
Controller
Dry Standards
Accessories
The TTurbCAL is a solid matter standard, which provides an FNU value for reagent-free calibration of TriOS
TTurb sensors. The standard is very easy to use and makes device calibration on site much easier.
Systems
83
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Accessories // Sensor
84
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Accessories
Sensor // Accessories
85
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Accessories // Sensor
86
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
G2 InterfaceBox // Accessories
G2 InterfaceBox
Photometer
11CX00000
Fluorometer
Radiometer
The G2 InterfaceBox is available in variants with and without WiFi. G2 sensors from TriOS Mess- und Daten-
technik GmbH can be configured and controlled via the interface box. This is enabled by the web interface of
the G2 sensors, which can be accessed via a WiFi or LAN connection. The web interface can be accessed
with any browser.
Technical Specifications
eCHEM
Voltage supply 24 VDC (± 10 %)
Power consumption ≤ 1.5 W plus sensor (only the WiFi variant)
Controller
Analog interfaces no
Switch input/output no
Standard IEEE 802.3, IEEE 802.11 b/g/n (only the WiFi variant)
Connection 1 RJ-45 external WiFi antenna (SMA) (only the WiFi variant)
Protocol TCP/IP (only with G2 sensors) Dry Standards
Web interface no
USB no
Data storage no
TTrig
Photometer
12C100000
Fluorometer
Radiometer
TTrig is a measurement interval switch for the TriOS G2 sensors OPUS and NICO. Due to its low standby power
(<1 mW), it is ideally suited for operation with a battery as power supply. It is designed to minimize energy
consumption between measurements.
The TTrig features an additional connection for commissioning and controlling a wiper (W55).
Remote or self-sufficient measuring stations can thus be operated maintenance-free for several months.
An RJ-45 Ethernet interface provides access to the sensor's G2 web interface for downloading the measure-
ment data from the data logger with a notebook.
eCHEM
Technical Specifications
Power supply
Voltage supply 12...24 VDC, max. 4A
Power in standby <1mW
Controller
Sensor interfaces
Connection M12 for TriOS G2 sensors; 1x RJ-45
Standard RS-485
Protocol Modbus RTU
Analog interfaces No
Dry Standards
OTHER INTERFACES
1x M8 connector for wiper W55
Connection
Trigger output
ENVIRONMENT
Operating temperature 0...+40 °C
Storage temperature -10...+70 °C
Accessories
SDI-12 Converter
Photometer
11C100001
Fluorometer
The SDI-12 converter translates the Modbus protocol used by TriOS sensors into SDI-12 and thus serves as
an interface between the sensors and the SDI-12 interface of the peripherals.
The SDI-12 converter translates the Modbus protocol used by TriOS sensors into SDI-12 and thus serves as
an interface between the sensors and the SDI-12 interface of the peripherals. Due to its low standby power
(< 20 mW) it is perfectly suited for operation with a battery as power supply. Four status LEDs inform the user
continuously about the current operation mode and power supply. Both, measurements with G2 sensors and
wiper cleaning cycles can be controlled via the converter. The implemented Ethernet interface allows data
Radiometer
export and sensor configuration via the web interface.
With three manual buttons Sensor Scan, Wiper Cleaning and Service Mode can be activated. The position of
the rotary encoder determines the sensor address via which the sensor is addressed.
Technical Specifications
External power Power supply 12…24 VDC (± 10 %)
supply Connection terminal 1.5 mm² (AWG 16)
eCHEM
Power supply 10…24 VDC (± 10 %)
SDI-12
Power consumption in standby < 20 mW
Interface
Protocol SDI-12
Controller
Connection terminal 1.5 mm² (AWG 16)
Sensor
Standard RS485
Interface
Protocol Modbus RTU
Standard Ethernet
Network*
Connection RJ45
Dry Standards
Operating temperature -10…+40 °C ~ 14 ˚F to +104 °F
Storage temperature -10…+70 °C ~ 14 ˚F to 158 ˚F
Relative air humidity 0…95 % (non-condensing)
Protection type IP30 NEMA 1
10A100003
Fluorometer
Radiometer
The FlowCell FC68 is used for bypass installation of the enviroFlu. The measurement medium is directed
eCHEM
The FlowCell FC48 is used for bypass installations of the TriOS Photometer with a diameter of 48 mm.
Different path lengths are available.
Systems
Ultrasonic FlowCell
Photometer
10A10001X
Fluorometer
Radiometer
FlowCell with integrated ultrasound cleaning
In addition to the conventional FlowCell, TriOS now offers an ultrasonic FlowCell, which combines the bypass
eCHEM
installation with direct cleaning.
Ultrasonic sound sprevents deposits forming on the measurement windows of the sensor. The built-in viewing
window and the illumination unit allow the state of the optical path be monitored at any time.
The FlowCell is suitable for a photometer with a 10 mm path as the FC 48/10 USC and for a photometer with
100 mm path as the FC 48/100 USC.
Controller
Technical Specifications
Max. internal pressure 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1gpm
Operating temperature +1...+40 °C ~ 34 ˚F to +104 ˚F
Accessories
Dimensions (width x
115 x 136 x 90 mm ~ 4.5" x 5.4" x 3.5"
height x depth)
Weight 1 kg 2.2 lbs
Materials Housing: Polyoxymethylene (POM)
Systems
10A0X0000
Fluorometer
Radiometer
attach it to the wall. The FlowCell can then simply be placed in front and attached with a bolt.
The system is designed to be modular, which means that every extension can be ordered individually and
customized according to the application. This gives you complete freedom in the design of your application
and you can adapt the system in just a few simple steps. The eCHEM FlowCell system is compatible with the
FlowCell for turbidity.
Controller
Dry Standards
Accessories
Systems
Photometer
10A090000
Fluorometer
Radiometer
eCHEM
FlowCell for Turbidity Sensors
Controller
10A050000
A specialized FlowCell was developed for
the sensors of the turbidity series to minimise
reflections. This design maximises the precision of
the measurements. This FlowCell is compatible with
the FlowCell for eCHEM sensors and the nanoFlu
FlowCell. Dry Standards
Accessories
Systems
Sedimenter
Photometer
02A100011
Fluorometer
Radiometer
The sedimenter is a flow-through device for use in turbid water. The sample is passed through the sedimenter
without pre-filtering. The sensor can also be installed in the sedimenter equipped with a wiper.
eCHEM
Suitable for OPUS, NICO, enviroFlu & microFlu. Version for LISA, LISA color and VIPER on request.
Technical specifications
Controller
Suitable for OPUS, NICO, enviroFlu & microFlu with and without wi-
Measuring device
per. Version for LISA, LISA color and VIPER on request.
Material PVC
Dimensions Installation plate for wall mounting: 800 mm x 495 mm
Dry Standards
Wiper W55 V2
Photometer
02A100008 • 02A100X18
Fluorometer
Radiometer
The TriOS Wiper W55 V2 provides an additional cleaning option for all TriOS photometers with path lengths
from 1 mm up to 10 mm. The wiper housing can be mounted on the sensor in just a few steps and provides
reliable cleaning of the measurement windows. The new magnetic axis lock allows quick and easy wiper
blade replacement, without any tools.
The new version of the wiper now features blockage detection and removal, and a service mode that increas-
es the life of the wiper through regular use. The accessory can also be used in seawater up to a depth of 10m.
eCHEM
Technical Specifications
4-pin M8-plug
Control port A suitable M8 connection cable with open end is included in the scope of
delivery.
Trigger input 5 ‒ 24 VDC (±10% )
Controller
Power consumption
2...15 mA
trigger input
Operating time (max.) 3 Seconds
Dimensions L x ø 175 mm x 80 mm
Weight 0.52 kg
Dry Standards
Material NBR, POM, TPE (PP, EPDM), Titanium, V4A
AirShot2
Photometer
02A100010
Fluorometer
The compact pressured air cleaning system AirShot2 works with pressured air pulses instead of a continuous
air flow, thus reducing the required amount of air significantly and enabling a very compact design.
Furthermore the pressure pulses perform a more effective cleaning than continuous air flow systems, making
Radiometer
Technical specifications
Energy supply
eCHEM
230 V Ver
230 VAC, max. 200 W, 0.86 A
Voltage sion
supply 110 V Ver
110 VAC, max. 200 W, 1.8 A
sion
Interfaces
Connection for 6 mm hoses ( 4 mm inner diameter )
Controller
Photometer
03A000003
Fluorometer
The TriBox mini supports operation of an external, controllable valve for the purposes of water or compres-
Radiometer
sed-air cleaning. All Solenoid Valve V2 settings can be configured via the TriBox mini menu ("Measurement
& Cleaning", sub-item "Cleaning").
The Solenoid Valve V2 can be installed very easily. It has four 5.3 mm holes for installation.
Available configurations:
• Interval cleaning
eCHEM
• Duration of cleaning
• Pause before measurement
Compressor
Controller
Sensor
Connection to TriBox mini
for 6 mm hoses (4 mm inner diame- for ~0.23" hoses (~0.16" inner diame-
Connection
ter) ter)
Housing Die-cast aluminium alloy
Protection type IP65 NEMA 4X
Cables 1.5 m connector cable with M8 plug ~ 4.9 ft connector cable with M8 plug
Temperature 2...+40 °C ~ 35.6 ˚F to +104 ˚F
Systems
07A000000
Fluorometer
Radiometer
The Modbus interface controls the sensor interfaces of the TriBox3, TriBox Mini or the TriOS G2 sensors
with connectors, providing simple, flexible connection options. The TriBox is connected via a standard M12
extension cable. TriOS G2 sensors with M12 connectors can be connected directly. To operate the sensors, a
power supply must be connected to the interface, which is connected directly to the sensor. Additional moun-
ting holes in the aluminium L profile make installation easy.
eCHEM
Technical Specifications
12…24 VDC (+/- 10%), only required for operation with sensors
Voltage supply
2 pin PCB plug connector
Dimensions (width x
110 x 40 x 95 mm ~ 4.3˝ x 1.6˝ x 3.7˝
height x depth)
Weight 180 g ~ 0.4 lbs
Accessories
Material Aluminium
Systems
TAMMO
Photometer
07A000001
Fluorometer
TAMMO is an expansion module for TriBox3, which converts analog signals to RS-485 Modbus RTU protocol.
The analog to Modbus module provides a total of two current inputs, where both the parameter and the unit
for two parameters can be set.
Radiometer
The TriBox3 must have at least software version V1.5.4 installed. For older versions, a soft
ware upgrade must be performed first.
Technical Specifications
Power supply
Power supply 12 V / 24 V (done by TriBox3)
eCHEM
Power consumption < 100 mW
Sensor interfaces
Connection terminal 1.5 qmm (AWG 16)
Standard RS-485
Protocol Modbus RTU
Controller
ANALOG INTERFACES
2x current input:
Analog input 4-20 mA (default setting in TriBox3)
0-20 mA (configurable at TriBox3)
Measurement accuracy ± 0,2 % of Full Scale Range
Dry Standards
Measurement rate ~ 60 SPS
Connection terminal 1.5 qmm (AWG 16)
AMbient
Operating temperature -10...+50 °C
Storage temperature -20...+70 °C
Relative air humidity 0...95 % (non-condensing)
Protection type IP00
Accessories
Mechanics
Dimensions L/W/H 59x32x28 mm
Weight 14 g
Float
Photometer
05A000005
Fluorometer
Radiometer
The TriOS float is the ideal solution for use in fluctuating water levels. The float comes with two sizes of
sensor brackets so that both the TriOS photometer with its 48 mm diameter and the enviroFlu with its 68 mm
eCHEM
diameter can be attached. One sensor at a time can be attached to the float.
TriOS also offers sensor brackets for small sensors, such as the nanoFlu (05A000006). With this, several
sensors can be attached to one float.
The float stays on the surface of the water with the sensor always in the medium. The float can easily be
removed from the medium by its handle to do a check or clean it. Side attachments of stainless steel cables
prevent the float from being carried away.
Controller
Dry Standards
Accessories
Systems
Pipe Adapter
Photometer
06A0000XX
For installation in existing pipe systems, such as pool edge fixtures, TriOS offers adapter pieces with G1 or
NPT1 thread for the following sensors:
Fluorometer
• TpH
• TpH-D
• TTurb
• Conductivity
• Oxygen
Radiometer
eCHEM
Controller
Dry Standards
Accessories
Systems
Telescopic Rod
Photometer
12A000000
Fluorometer
Radiometer
The new TriOS telescopic rod provides a solid and reliable mounting method for the TriOS dissolved oxygen
eCHEM
sensor. The sensor is permanently mounted in the head section of the telescopic rod and can be immersed in
the medium by extending the telescopic tubes to a distance of 6.8m. The rod can be held by hand or attached
to a railing or similar with the supplied double clamp. Due to the material mix of carbon and fiberglass, the rod
is grippy and light at the same time.
Controller
Technical specifications
RAMSES Frames
Photometer
05A000000
Fluorometer
Radiometer
05A000002
eCHEM
Controller
Hydraulic Clamps CL48 & CL68 Dry Standards
01A100000X
Accessories
Systems
11A10000X
The modern TriOS bypass panel makes it possible to cleanly and precisely monitor water quality on site. The
Fluorometer
sensor is passed through the FlowCells and thus analysed for various parameters. The panel can be ordered
in different designs and sensor assemblies.
Radiometer
eCHEM
Controller
Dry Standards
11A100002 Water quality panel with pH, conductivity, turbidity, chlorine, TriBox mini
Accessories
11A100003 Water quality panel with pH, conductivity, turbidity, chlorine, TriBox 3
11A100004 Water quality panel with pH, conductivity, turbidity, TriBox mini
Systems
pH Buffer Set
Photometer
80P000002
Fluorometer
Radiometer
pH Buffer Solution
TriOS provides the necessary certified buffer solution with pH4 and pH 7 to calibrate TriOS TpH-D sensors.
No transfer of fluids necessary, as the containers fit directly into the calibration process.
Quick and easy calibration of all EGC Quality Analyzer sensors directly at the site. No dangerous fluids, no
eCHEM
expertise needed! Let the wizard of the TriBox guide you through every step of the process.
Controller
Dry Standards
Accessories
Systems
Panels
Photometer
11A10000X
Fluorometer
Radiometer
02A100003
Accessories
Systems
Photometer
00P100005 . 00P100010
Fluorometer
Radiometer
Cuvette holder
for 5 mm quartz glass cuvette with 10 mm path*
10A200000
eCHEM
Controller
*For all photometers: OPUS, LISA, LISA color, VIPER, NICO
05A000004
Fluorometer
Radiometer
Cable
50A0XXXX0
eCHEM
Controller
50A000001
Accessories
Systems
109
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Systems // Sensor
110
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
SystemS
Sensor // Systems
111
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Systems // EGC Water Analyzer
11A10001X
Fluorometer
Radiometer
eCHEM
The EGC Water Analyzer is TriOS‘ latest development in the monitoring of various wastewater-parameters.
It can be equipped with three sensors: enviroFlu for identification of polycyclic aromatic hydrocarbons (PAH),
TTurb for turbidity measurements and TpH-D for the determination of the pH value.
Inside the measurement cabinet is a TriBox3 to which all sensors are connected. The Ethernet interface and
the analogue outputs are directly connected to the transparent connector box.
Controller
Equipped with the enviroFlu, TTurb and TpH-D in the appropriate configuration, a TriBox3 (from software
version 1.4.22) and wire rope dampers, the analyzer has a ship approval according to IMO regulations
MEPC.259(68).
Systems
Technical Specifications
Photometer
Power supply
Voltage supply 100 … 240 VAC, 50 … 60 Hz
Power consumption Max. 50 W
Interfaces
Fluorometer
digital Ethernet
analogue 6 outputs: 4…20 mA
Load max. 500 Ω
Protocol Modbus TCP/IP
PAH (MEPC.259(68))
pH (BS EN 60746-2:2003)
Radiometer
Turbidity (DIN EN ISO 7027:2016)
Parameters
Temperature (of TpH-D)
Flow (internal)
PAH turbidity corrected
Mechanical system
Size (width x height x
600 x 800 x 337 mm ~ 23.6“ x 31.5“ x 13.3“
depth)
eCHEM
43 kg (without sensors) ~ 95 lbs (without sensors)
Weight
45.5 kg (with sensors) ~ 100 lbs (with sensors)
Environment
Sample temperature +2°C…+40°C ~ +36 °F to +104 °F
Ambient temperature 0°C…+45°C ~ +32 °F to +113 °F
Storage temperature -20°C…+80°C ~ -4 °F to +176 °F
Controller
Relative air humidity 0...95% (non-condensing)
pH value > pH4
Protection type IP56 NEMA 4
Inlet
Inlet pres-
Max. pres 1 to 25 bar maximum ~ 14.5 psig to 363 psig maximum
Dry Standards
sure
sure
Internal max. 3 bar ~ 43.5 psig
Flow volume 2...5 L/min
Internal volume Approx. 1 L
Accessories
Systems
MEAS100
Photometer
11A100007
Fluorometer
Radiometer
eCHEM
Controller
Technical Specifications
Housing ment, each with lockable door. Upper door with Plexiglas window.
Protective cover made of Styrosun that can be propped open for
connection and maintenance work
Independent, regulated cooling / heating with four settings, no-frost
Sample compartment temperature:
Thermostatic control
~ +39.2 °F (adjustable from
4 °C (adjustable from 0...9.9 °C)
32...49.8 °F)
Systems
Photometer
Sampling modes Time-dependent, volume-dependent, event controlled, manual
Microprocessor control, sleep mode (<5 mA), 8-16 V power supply, foil
Control keypad, with key field (0-9, ESC, ENT, cursor keys)
graphical display (128x64 pixels), background illumination
3000 entries, non-volatile data memory;
Data storage sampling and malfunction report data, including sample extractions, bottle
changes, reports, external signals
Fluorometer
Programming Twelve (12) freely programmable application programs with program links
• Immediately
• Date / time
Program start options
• Day of week / time
• With external signal
• After 1 run
Programme end / stop
options • After X runs
Radiometer
• Continuous operation
• Date/time
Pause mode Interruption of program run at any time
Overfilling protection Adjustable from 1–999 samples / bottles
Intervals setting 1 min. to 99 h 59 min in steps of 1 minute
Pulse setting 1 to 9999 pulses/sample
Manual sample extraction Possible at any time without interrupting the current program run
eCHEM
Program protection Up to 5 years after loss of power supply
Controller
98.4 ft
Signal output / status
8 digital; 1 of them being the collective malfunction message
messages
Vacuum system 1000 ml
Metering system
U system, suction height up to 40 m / 131.2 ft
Single sample volume
Vacuum system: < 2.5 % or +/- 3 ml
accuracy Dry Standards
Dimensions (height x 1490 (2040 with open cover) x 605 x ~ 58.7" (80.3" with open cover) x
width x depth) 645 mm 23.8" x 25.4"
Weight ~ 110 kg with composite container ~ 242.5 lbs with composite container
Materials with medium
PC, PVC, silicone, PS, PE, EPDM
contact
Auxiliary power / Power
230 V / 115 V /AC
Accessories
supply
Power consumption approx. 350 VA (with cooling)
Ambient -20...+43 °C ~ -4 °F to +109.4 °F
Sample temperature 0...+40 °C ~ +32 °F to +104 °F
Standards CE; sampling according to ISO 5667-10, EN16479
Systems
wall-mounted sampler
For use in hard-to-reach measuring points, for
example, TriOS has taken the proven stationary
Fluorometer
117
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Annex
Annex
D02-000en202204 TriOS Catalogue 119
Opus UV: measurement ranges depending on the path length*
120
Annex
Parameters Measurement principle Unit Factor Path length (mm)
0.3 1 2 5 10 20 50
Absorbance (AU) Spectral AU** - 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2
Absorbance (1/m) Spectral 1/m - 50...7300 15...2200 7.5...1100 3...440 1.5...220 0.75...110 0.3...44
Nitrate N-NO3 Spectral mg/L - 1.0...330 0.3...100 0.15...50 0.06...20 0.03...10 0.015...5 0.006...2
Nitrate NO3 Spectral mg/L - 4.43...1460 1.33...440 0.67...220 0.27...88 0.13...44 0.067...22 0.030...9
Nitrite N-NO2 Spectral mg/L - 1.7...500 0.5...150 0.25...75 0.1...30 0.05...15 0.025...7.5 0.01...3
Nitrite NO2 Spectral mg/L - 5.6...1650 1.65...500 0.82...250 0.33...100 0.17...50 0.083...25 0.033...10
DOCeq Spectral mg/L - 17...3300 5.0...1000 2.5...500 1.0...200 0.5...100 0.25...50 0.1...20
TOCeq Spectral mg/L - 17...3300 5.0...1000 2.5...500 1.0...200 0.5...100 0.25...50 0.1...20
CODeq Spectral mg/L - 100...7300*** 30...2200*** 15...1100*** 6.0...440*** 3.0...220*** 1.5...110*** 0.6...44***
BODeq Spectral mg/L - 100...7300*** 30...2200*** 15...1100*** 6.0...440*** 3.0...220*** 1.5...110*** 0.6...44***
KHP Spectral mg/L - 17...13300 5.0...4000 2.5...2000 1.0...800 0.5...400 0.25...200 0.1...80
SAC254 Single wavelengths 1/m - 50...7300 15...2200 7.5...1100 3.0...440 1.5...220 0.75...110 0.3...44
COD-SACeq**** Single wavelengths mg/L 1.46 75...10600 22...3200 11...1600 4.4...640 2.2...320 1.1...160 0.44...64
BOD-SACeq***** Single wavelengths mg/L 0.48 24...3500 7.2...1050 3.6...525 1.44...210 0.72...105 0.36...52.5 0.15...21
TSSeq***** Single wavelength mg/L 2.6 130...4300 40...1300 20...650 8.0...260 4...130 2.0...65 0.8...26
D02-000en202204 TriOS Catalogue
Note:
1 mg/L N-NO3 is equivalent to 4.43 mg/L NO3
1 mg/L N-NO2 is equivalent to 3.28 mg/L NO2
VIPER: measurement ranges depending on the path length*
D02-000en202204 TriOS Catalogue
Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
10 50 100 150 250
SAC436 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
SAC525 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
SAC620 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
True colour 410 DIN EN ISO 7887: 2012-04 mg/L Pt 18.52 20...3750 4...750 2...375 1.2...250 0.8...150
Pt-Co color 390 DIN EN ISO 6271:2016-05 mg/L Pt 7.4 8...1500 1.6...300 0.8...150 0.4...100 0.2...60
Pt-Co-Color 455 DIN EN ISO 6271:2016-05 mg/L Pt 36.4 40...7500 8...1500 4...750 2.4...500 1.4...300
Cr-Co color 380 - ° (degree of colour) 9.7 10.0...2000 2...400 1...200 0.6...130 0.4...80
Cr-Co colour 413 Gost 3351-74 ° (degree of colour) 34.1 40...7000 8...1400 4...700 2.6...450 1.6...275
Annex
121
Annex
Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
1 2 5 10 50
SAC254 DIN 38404-3: 2005-07 C3 1/m - 5...1500 2.5...750 1...300 0.5...150 0.1...30
CODeq** - mg/L 1.46 8...2200 4...1100 1.5...440 0.8...220 0.15...45
BODeq** - mg/L 0.48 2.5...700 1.25...350 0.5...140 0.25...70 0.05...15
TOCeq** - mg/L 0.584 3...880 1.5...440 0.6...175 0.3...90 0.06...20
Turbidity 530 nm - FAU*** 3.2054 / 0.0096 20...4000 10...1400 4...420 2...200 0.4...40
D02-000en202204 TriOS Catalogue
Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
10 50 100 150 250
SAC436 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
SAC525 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
SAC620 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
True color 410 DIN EN ISO 7887: 2012-04 mg/L Pt 18.52 10.0...2800 2...560 1.0...280 0.6...185 0.4...110
Pt-Co color 390 DIN EN ISO 6271:2016-05 mg/L Pt 7.4 4.0...1100 0.8...220 0.4...110 0.3...75 0.2...45
Pt-Co-Color 455 DIN EN ISO 6271:2016-05 mg/L Pt 36.4 20...5500 4.0...1100 2.0...550 1.5...360 0.8...220
Cr-Co color 380 - ° (degree of colour) 9.7 5.0...1500 1.0...300 0.5...150 0.3...100 0.2...60
Cr-Co color 413 Gost 3351-74 ° (degree of colour) 34.1 20...5500 4.0...1100 2.0...550 1.5...360 0.8...220
Annex
* under laboratory conditions
123
Annex
Path length Path length Path length Path length Path length Path length Path length
Parameters Unit Factor
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
0,3 1 2 5 10 20 50
Nitrate NO3-N [mg/L] - 0…200 0…60 0…30 0…12 0…6 0…3 0…1.2
Nitrate NO3 [mg/L] - 0…886 0…266 0…133 0…53 0…26.6 0…13 0…5
D02-000en202204 TriOS Catalogue
Chlorine Dioxide
Cyanobacteria
Chlorophyll a
Nitrate NO3-N
Free Chlorine
Nitrite NO2-N
COD-SACeq
BOD-SACeq
Temperature
TOC-SACeq
Conductivity
Solid matter
Fluorescein
Rhodamine
Tryptophan
Irradiance
Radiance
Coloring3
pH value
Turbidity
Oxygen
CODeq
DOCeq
BODeq
TOCeq
TSSeq
SAC254
SAC436
cdom
BTX4
KHP
D02-000en202204 TriOS Catalogue
OPUS
OPUS aero
NICO
Absorption NICO plus
LISA UV
LISA color5
VIPER
enviroFlu5
matrixFlu VIS
Fluorescence nanoFlu5
microFlu HC
microFlu V2
Radiometry RAMSES
TTurb
TpH
TpH-D
Conductivity
eCHEM Conductivity inductive
Dissolved Oxygen
Free Chlorine
Chlorine Dioxide
Annex
Total Chlorine
1
390 nm, 455 nm (Apha/Hazen)
2
380 nm, 413 nm
3
410 nm, 436 nm, 525 nm, 620 nm
4
mono-aromatic hydrocarbons
125
5
depending on version
Annex
SDI-12 Converter
compatible
TriOS Protocol Modbus able
(Device Driver availa-
ble)
OPUS
OPUS aero
NICO
Absorption NICO plus
LISA UV
LISA color5
VIPER
enviroFlu
enviroFlu HC MB
matrixFlu VIS
Fluorescence
nanoFlu
microFlu HC
microFlu V2
RAMSES
Radiometry
RAMSES G2
Turbidity TTurb
TpH
TpH-D
Conductivity
Conductivity Induktive
eCHEM
Dissolved Oxygen
Free Chlorine
Chlorine Dioxide
Total Chlorine