TriOS Catalogue (2022)

The TriOS G2 Interface provides a flexible and intuitive connection to TriOS sensors and measurement devices. It uses a web browser-based system that is operating system independent. All G2 sensors have internal memory to store measurement data and events. The easiest way to connect is with the G2 Interface Box, which establishes the connection, provides power, and can be used universally for all G2 sensors. The G2 Interface modernizes how users interact with TriOS technology through improved connectivity and configuration options.

Uploaded by

ABMOHE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views130 pages

TriOS Catalogue (2022)

The TriOS G2 Interface provides a flexible and intuitive connection to TriOS sensors and measurement devices. It uses a web browser-based system that is operating system independent. All G2 sensors have internal memory to store measurement data and events. The easiest way to connect is with the G2 Interface Box, which establishes the connection, provides power, and can be used universally for all G2 sensors. The G2 Interface modernizes how users interact with TriOS technology through improved connectivity and configuration options.

Uploaded by

ABMOHE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 130

Product Catalog

2022
Table of contents

Opening credits DryCAL 82


Company history 2 TTurbCAL 82
TriOS G2 Interface 4
Accessories
Photometer G2 Interface Box 87
OPUS 8 TTrig 88
OPUS aero 12 SDI-12 Converter 89
NICO 14 FC 68 FlowCell 90
NICO plus 16 FC 48 FlowCell 90
LISA UV 18 Ultrasonic FlowCell 91
VIPER 20 FlowCells for eCHEM Sensors 92
LISA color 24 FlowCells for nanoFlu 93
FlowCell for Turbidity Sensors 93
Fluorometer
Sedimenter 94
enviroFlu 30
Wiper W55 V2 95
nanoFlu 34
AirShot2 96
matrixFlu VIS 36
Solenoid Valve V2 97
microFlu V2 38
Modbus Interface Board 98
microFlu V2 HC 40
TAMMO 99
Radiometer Float 100
RAMSES 44 Pipe Adapter 101
RAMSES G2 47 Telescopic Rod 102
RAMSES Frames 103
eChem
CL48 & CL68 Hydraulic Clamps 103
pH Sensor TpH 52
Water Quality Panel 104
Differential pH Sensor TpH-D 54
pH Buffer Set 105
TTurb 56
Panels 106
Conductivity Sensor 58
Flange 106
Inductive Conductivity Sensor 60
Compressed-air Cleaning Head 106
Dissolved Oxygen Sensor 62
Protective Cage 107
Free Chlorine Sensor 64
Cuvette Holder 107
Chlorine Dioxide Sensor 66
VALtub 107
Total Chlorine 68
Optics Cleaning Set 108
Controller Cables 108
TriBox3 72 5-input M12 Sensor Connector Box 108
TriBox mini 74
Systems
TriBox mini NET 74
EGC Water Analyzer 112
HS100 76
MEAS100 114
DRY Standards Wall-Mounted Sampler 116
SolidCAL 80
Annex 119
FieldCAL 81

D02-000en202204 TriOS Catalogue 1


Annex

A success story.
When TriOS Mess- und Datentechnik GmbH was vacationers accompany the devices, even if
founded in 1998, the further development path was certainly not consciously perceived, on their journey
not foreseeable. With the R&D project funded under along the fjords on the ships of the Hurtigruten.
the project name RAMSES by the BMBF (Federal Today, the former university spin-off, which has
Ministry of Education and Research), the foundation been managed by Rüdiger Heuermann alone since
stone for a success story in optical measurement 2000, has become a leading company in the field of
technology was laid during the founding phase optical immersion sensors.
of TriOS GmbH. RAMSES was the first spectral- In addition to the original RAMSES radiometers, the
resolution light measurement instrument available TriOS product range has expanded visibly. Innovative
on the market for use in marine research. measuring instruments for algae detection, for the
Today, the product name „RAMSES“ is measurement of smallest amounts of oil in water,
synonymous with compact, robust and reliable the reagent-free determination of nutrients and
light measurements, with over a thousand organic substances followed, whereby the business
instruments in use worldwide - the clear No. 1 in field of TriOS Mess- und Datentechnik GmbH has
the world. The instruments are routinely used to expanded far beyond the field of marine technology
measure light distribution in the water column as into water quality, drinking water and wastewater
well as for validation and calibration of advanced monitoring and many industrial applications. Among
environmental satellite data (e.g. MERIS). The other things, TriOS is one of the leading companies
sensors have proven their reliability in many adverse in the field of oil-in-water monitoring and thus makes
environmental conditions, such as in Antarctica, but a significant contribution to reducing environmental
also in unusual locations such as offshore racing pollution caused by oil discharges.
yachts in the Volvo Ocean Race. Many Norwegian With the expansion of the product range and the

2 D02-000en202204 TriOS Catalogue


Annex

increase in the number of units produced, the need TpH-D for pH. In addition, the flow rate, temperature
for production space and qualified employees as well as the turbidity-corrected PAH value can be
grew. Thus, the move to the newly built company determined.
headquarters in Rastede took place in July 2011. In addition, novel sensors for environmentally
This laid the foundation for significantly increasing relevant parameters are currently being developed
the vertical range of manufacture by means of in- in several research projects in cooperation with
house CNC machining, modern PCB assembly universities and research institutes. Many of our
and device production, and thus having all quality- customers are also partners in the development of
relevant processes in-house. In 2019, the company new products.
premises were also expanded with additional My special thanks, also on behalf of all TriOS
warehouse and production buildings to meet employees, go to these partners, without
the enormous market demand. Equipped with whom TriOS would not exist in its current form.
state-of-the-art technology, this has also allowed
development to grow and deepen in-house. Almost Rüdiger Heuermann
all TriOS products thus rightly bear the status „Made Managing Director
in Germany“. TriOS has remained true to its drive for
innovation. One of the latest TriOS products on the
market is the EGC Water Analyzer - a measuring
cabinet for determining various parameters in wash
water from exhaust gas scrubbers on ships. It
can be equipped with three types of sensors: the
enviroFlu for PAH, the TTurb for turbidity and the

D02-000en202204 TriOS Catalogue 3


G2 Interface
Annex

The TriOS G2 Interface


The rapid change in the way we communicate and G2 interface concept which, in addition to a very
interact with technology has been evident not only flexible connection to process control systems and
since the ubiquitous spread of smartphones. This data acquisition systems, also enables intuitive con-
development is also having more and more influ- figuration and operation using operating system-in-
ence on measurement technology. To meet these dependent web browsers.
requirements, TriOS has developed the innovative

All G2 sensors are equipped with an internal memo-


ry. This enables the storage of all measurement data
and events. The easiest way to establish a connec-
tion to the G2 sensors is to use the G2 interface box
(with or without WiFi module). The box is used for
establishing the connection as well as for the power
supply and can be used universally for all TriOS G2
sensors.

4 D02-000en202204 TriOS Catalogue


G2 Interface
Annex

Three steps into the TriOS G2 interface

1. Connect

2. Open browser

3. Enter URL http://192.168.77.1/ or http://OPUS_7063

Ready!

D02-000en202204 TriOS Catalogue 5


D02-000en202204 TriOS Catalogue
Photometer // Sensor

6
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Photometer
Sensor // Photometer

7
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Photometer // OPUS

OPUS
Photometer

12SXXXXX0
Fluorometer

OPUS is the new generation of spectral sensors a web browser. Integration into existing process
for online measurement of nitrogen and carbon control systems and external data loggers has never
compounds. Through the analysis of a full spectrum, been easier.
Radiometer

OPUS is able to deliver reliable readings for NO3-N,


With the optional battery pack, mobile applications
NO2-N, organic ingredients (CODeq, BODeq, DOCeq,
are also feasible. WiFi connectivity allows laptops,
TOCeq), and a number of other parameters.
tablets or smartphones to be easily used for control
OPUS features the new TriOS G2 interface, allowing without any special application software or app
fast and easy configuration of sensors by using installation.

Benefits Applications
eCHEM

• Without sampling and preparation of test • Sewage treatment plants


samples
• Environmental monitoring
• Real-time sensor
• Drinking water monitoring
• Without reagents
• Industrial applications
• Optical window with nano coating
Controller

• Pre-installed application calibration

Absorption spectrum with/without CODeq


Absorptionsspektrum Abwasser mit/ohne CSBeq
3
Dry Standards

Nitrate
Nitrat
2,5

Nitrit
Nitrite
2
Absorption [AU]
Absorption [AU]

1,5 BODeq / DOCeq


CSB / TOC
CODeqeq / TOC
eq
Accessories

eq
1
SAK254 TSS
TSS
SAC 254

0,5

0
190 210 230 250 270 290 310 330 350
Wavelength
Wellenlänge[nm]
[nm]
Systems

8 D02-000en202204 TriOS Catalogue


OPUS // Photometer

Technical Specifications

Photometer
light source Xenon flash lamp
High-end miniature spectrometer
Measure­
ment tech­ 256 Channels
nology detector
200 to 360 nm

Fluorometer
0.8 nm/pixel
Measurement principle Attenuation, spectral analysis
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm

Parameter See parameter list p. 10


Measuring range See parameter list p. 10
Measurement accuracy See parameter list p. 10

Radiometer
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min

Stainless steel (1.4571/1.4404), titanium (3.7035),


Housing material
Deep Sea Version: titanium (3.7035)

eCHEM
~ 470 mm x 48 mm (10 mm path) ~ 18.5“ x 1.9“ (with10 mm path)
Dimensions (L x Ø)
Deep Sea Version: ~ 511 x 59 mm Deep Sea Version: ~ 20.1“ x 2.3“
stainless steel ~ 3 kg (with 10 mm path) ~ 6.6 lbs (with 10 mm path)
Weight ~ 2 kg ~ 4.4 lbs
titanium
Deep Sea Version: ~ 4 kg Deep Sea Version: ~ 8.8 lbs

Ethernet (TCP/IP)
Interface digital

Controller
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤8W
Power supply 12...24 VDC (± 10 %)

Maintenance effort ≤ 0.5 h/month (typical)


Calibration/maintenance
24 months
Dry Standards
interval
System compatibility Modbus RTU
Warranty 1 year (EU: 2 years) US: 2 years

30 bar ~ 435 psig


with SubConn
Max. Deep Sea Version: 600 bar Deep Sea Version: ~ 8702.26 psig
pressure with fixed cable 3 bar ~ 43.5 psig
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Accessories

Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Systems

D02-000en202204 TriOS Catalogue 9


Photometer // OPUS
Photometer

Measuring Range
Single parameter under optimum laboratory conditions
Path Measurement Measuring Detection Limit of Precisi-
(mm) Parameter principle Unit range limit determination on Accuracy*
Nitrate NO3-N Spectral mg/L 0...100 0.3 0.5 0.05 ± (5 % + 0.1)
Nitrite NO2-N Spectral mg/L 0...150 0.5 1.2 0.12 ± (5 % + 0.1)
Fluorometer

CODeq Spectral mg/L 0...2200*** 30 100 10


BODeq Spectral mg/L 0...2200*** 30 100 10
DOCeq Spectral mg/L 0...1000 5 10 1
1 TOCeq Spectral mg/L 0...1000 5 10 1
TSSeq Spectral mg/L 0...1500 60 200 20
KHP Spectral mg/L 0...4000 5 10 1 ± (5 % + 2)
SAC254 Single wavelength 1/m 0...2200 15 50 5
Radiometer

COD-SACeq** Single wavelength mg/L 0...3200 22 73 7.3


BOD-SACeq** Single wavelength mg/L 0...1050 7.2 24 2.4

Nitrate NO3-N Spectral mg/L 0...10 0.03 0.05 0.005 ± (5 % + 0.01)


Nitrite NO2-N Spectral mg/L 0...15 0.05 0.12 0.012 ± (5 % + 0.01)
CODeq Spectral mg/L 0...220*** 3 10 1
BODeq Spectral mg/L 0...220*** 3 10 1
eCHEM

DOCeq Spectral mg/L 0...100 0.5 1 0.1


10 TOCeq Spectral mg/L 0...100 0.5 1 0.1
TSSeq Spectral mg/L 0...150 6 20 2
KHP Spectral mg/L 0...400 0.5 1 0.1 ± (5 % + 0.2)
SAC254 Single wavelength 1/m 0...220 1.5 5 0.5
COD-SACeq** Single wavelength mg/L 0...320 2.2 7.3 0.73
BOD-SACeq** Single wavelength mg/L 0...105 0.72 2.4 0.24
Controller

* Based on a standard calibration solution


** Based on KHP (100 mg/L COD standard solution correspond to 85 mg/L KHP)
*** Depending on composition of COD and BOD (checksum parameter)
1 mg/L NO3-N correspond to 4.43 mg/L NO3
Dry Standards

1 mg/L NO2-N correspond to 3.28 mg/L NO2


Accessories
Systems

10 D02-000en202204 TriOS Catalogue


OPUS // Photometer

OPUS G2 Interface

Photometer
The easiest and fastest way of sensor integration and configuration in any process control system or data
logger via web browser:

Fluorometer
Radiometer
eCHEM
Let OPUS automatically monitor your processes and react to unexpected events or incidents with the optio-
nal "policing" feature of OPUS.

Controller
Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 11


Photometer // OPUS aero

OPUS aero
Photometer

12SXXXXXX
Fluorometer
Radiometer

OPUS aero is the new generation of spectral a web browser. Integration into existing process
sensors for online measurement of nitrate and control systems and external data loggers has never
nitrite in wastewater aeration tank. By analyzing a been easier.
complete spectrum, OPUS aero is able to provide
WiFi connectivity allows laptops, tablets or
reliable readings for either NO3-N only or NO3-N and
smartphones to be easily used for control without
NO2-N, depending on the calibration.
any special application software or app installation.
eCHEM

OPUS features the new TriOS G2 interface, allowing


fast and easy configuration of sensors by using

Benefits Applications
Controller

• Without sampling and preparation of test • Wastewater aeriation tank


samples
• Real-time sensor
• Without reagents
Dry Standards

• Optical window with nano coating


• Pre-installed application calibration

Path (mm) Nitrate N-NO3 Nitrite N-NO2

0,3 2.4...120 4.4..220


Accessories

1 0.7...36 1.3...67
2 0.35...18 0.65...33.5
Systems

12 D02-000en202204 TriOS Catalogue


OPUS aero // Photometer

Technical Specifications

Photometer
light source Xenon flash lamp
High-end miniature spectrometer
Measure­
ment tech­ 256 Channels
nology detector
200 to 360 nm

Fluorometer
0.8 nm/pixel
Measurement principle Attenuation, spectral analysis
Optical path 0.3 mm, 1 mm, 2 mm

Parameter Nitrate NO3-N or Nitrate NO3-N+Nitrite NO2-N


Measuring range See parameter list
Measurement accuracy ± (5 % + 0.1)

Radiometer
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min

Housing material Stainless steel (1.4571/1.4404)


Dimensions (L x Ø) ~ 470 mm x 48 mm ~ 18.5“ x 1.9“

eCHEM
Weight stainless steel ~ 3 kg ~ 6.6 lbs

Ethernet (TCP/IP)
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤8W
Power supply 12...24 VDC (± 10 %)

Controller
Maintenance effort ≤ 0.5 h/month (typical)
Calibration/maintenance
24 months
interval
System compatibility Modbus RTU
Warranty 1 year (EU: 2 years) USA: 2 years

Max. with fixed cable 3 bar ~ 43.5 psig Dry Standards


pressure in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Accessories

Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps


Systems

D02-000en202204 TriOS Catalogue 13


Photometer // NICO

NICO
Photometer

15SXXXXXX
Fluorometer

The Low-Cost Nitrate Meter from TriOS

Based on the innovative instrument platform con- Equipped with our innovative G2 interface with web
Radiometer

cept of TriOS, on which OPUS, LISA and VIPER, browser configuration and internal data logger, NICO
among others, are based, NICO is a cost-effective has features that are significantly above the current-
UV photometer for nitrate determination. The three ly available devices on the market, in combination
detection channels provide precise optical nitrate with an attractive price.
determination by absorption, taking into account tur-
The uniform instrument platform of all TriOS photom-
bidity and organics, which are a problem with many
eters also stands for a uniform spare parts and con-
products currently on the market.
sumables system, which enables the use of the wide
An internal temperature correction additionally in- range of accessories available for our instruments.
eCHEM

creases the stability of the measured values. The modern G2 interface also offers fast integration
into third-party systems.

Benefits Applications

• Proven UV-absorption method • Sewage treatment plants


Controller

• Without sampling and preparation of test • Environmental monitoring


samples
• Drinking water monitoring
• Real-time sensor
• Without reagents
• Optical window with nano coating
Dry Standards
Accessories
Systems

14 D02-000en202204 TriOS Catalogue


NICO // Photometer

Technical Specifications

Photometer
Measurement­ light source Xenon flash lamp
technology detector 4 photo diodes + filter
Measurement principle Attenuation
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 50 mm

Fluorometer
Parameters NO3-N, NO3, NOx-N, NOx (calibrated with NO3 standard solution)
Measurement 1 mm path 0.5...60 mg/L NO3-N
range 10 mm path 0.05...6 mg/L NO3-N
± (5 % + 0.1 mg/L NO3-N) with 10 mm path
Measurement accuracy
± (5 % + 1 mg/L NO3-N) with 1 mm path
Turbidity compensation Yes

Radiometer
Data Logger ~ 2 GB
Reaction time T100 20 s
Measurement interval ≥ 10 s

Housing material Stainless steel (1.4571/1.4404), titanium (3.7035),


Dimensions (L x Ø) ~ 470 mm x 48 mm (10 mm path) ~ 18.5“ x 1.9“ (with10 mm path)
stainless steel ~ 3 kg ~ 6.6 lbs

eCHEM
Weight
titanium ~ 2 kg ~ 4.4 lbs

Ethernet (TCP/IP)
Interface digital
RS-485 (Modbus RTU)
Power consumption ≤7W
Power supply 12...24 VDC (± 10 %)

Controller
Required supervision Typically ≤ 0.5 h/month
Calibration / maintenance
24 months
interval
System compatibility Modbus RTU
Warranty 1 year (EU: 2 years) US: 2 years

with Subconn 30 bar ~ 435 psig Dry Standards


Max. pres­
with fixed cable 3 bar ~ 43.5 psig
sure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Accessories

Storage temperature -20...+80 °C ~ -4 °F to +176 °F


Inflow velocity 0.1...10 m/s ~ 0.33 to 33 fps
Systems

D02-000en202204 TriOS Catalogue 15


Photometer // NICO plus

NICO plus
Photometer

16AXX10X0
Fluorometer
Radiometer

The new all-rounder from TriOS - Now with a new turbidity compensation*

As a new all-rounder, NICO plus not only offers the Equipped with our innovative G2 interface with web
parameters NO3-N, NO3, NOx-N and NOx previously browser configuration and internal data logger, NICO
known from NICO, but has now been expanded to in- plus has features that are significantly above the cur-
clude numerous parameters. These include UVT254, rently available devices on the market, in combina-
UVT254n, SAK254, CSBeq, BSBeq, TOCeq, DOCeq, tur- tion with an attractive price.
eCHEM

bidity and TSSeq.


The instrument platform of all TriOS photometers
An internal temperature correction additionally in- stands for uniform spare parts and consumables and
creases the stability of the measured values. universal use of the wide range of accessories.

Parameter Measuring range (at 10 mm) Detection limit


Controller

NO3 0.22... 22 ppm 0.22 ppm


NO3-N 0.05...5 ppm 0.05 ppm
NOx 0.22... 22 ppm 0.22 ppm
NOx-N 0.05...5 ppm 0.05 ppm
UVT254 25...96.6 % 96.6 %
25...96.6 % 96.6 %
Dry Standards

UVT254n
(referred to 10 mm cuvettes) (referred to 10 mm cuvettes)
SAC254** 1.5...60 1/m 1.5 1/m
CODeq 2.2…90 ppm 2.2 ppm
BODeq 0.7…30 ppm 0.7 ppm
TOCeq 1…35 ppm 1 ppm
DOCeq 1…35 ppm 1 ppm
Accessories

Turb 5…200 FAU*** 5 FAU***


TSSeq 5…180 ppm 5 ppm

* Turbidity measurement according to DIN EN ISO 7027


** based on the procedure DIN 38404 - C3
*** FAU: Formazine Attenuation Unit
Systems

16 D02-000en202204 TriOS Catalogue


NICO plus // Photometer

Technische Spezifikationen

Photometer
Measurement light source Xenon flash lamp
technology detector 4 photo diodes + filter
Measurement principle Attenuation
Optical path 0.3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 20 mm, 50 mm

Fluorometer
Parameters See parameter list
Measurement range See parameter list
Measurement accuracy ± (5 % + 2-fold detection limit)
Turbidity compensation Yes
Data Logger ~ 2 GB

Radiometer
Reaction time T100 20 s
Measurement interval ≥ 10 s

Housing material Stainless steel (1.4571/1.4404)


Dimensions (L x Ø) ~ 470 x 48 mm (with 10 mm path) ~ 18.5“ x 1.9“ (with10 mm path)
Weight VA ~ 3 kg ~ 6.6 lbs

Ethernet (TCP/IP)

eCHEM
Interface digital
RS-485 (Modbus RTU)
Power consumption ≤7W
Power supply 12 – 24 VDC (± 10 %)
Required supervision Typically ≤ 0.5 h/month
Calibration/maintenance interval 24 months

Controller
System compatibility Modbus RTU
Warranty 1 year (EU & USA: 2 years) USA: 2 years

with SubConn 30 bar ~ 435 psig


Max. pressure with fixed cable 3 bar ~ 43.5 psig
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Dry Standards
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 to 33 fps
Accessories
Systems

D02-000en202204 TriOS Catalogue 17


Photometer // LISA UV

LISA UV
Photometer

14SXXXXX0
Fluorometer

LISA – The innovative SAC254 sensor by TriOS can easily be configured through any standard web
browser on a PC, tablet or Smartphone.
Long-lasting and energy-efficient UV-LED technolo-
gy and a robust design are the outstanding features The optical path length can be adapted to the application
Radiometer

of LISA UV. Like all TriOS sensors LISA uses the at any time by various adapters. An automatic turbidity
unique nanocoated windows combined with com- compensation is carried out via a second measuring
pressed air flushing to achieve long operating times channel.
without cleaning.
Through application-specific correlation LISA UV
The innovative TriOS G2 interface allows quick and can be configured for direct output of BODeq, CODeq,
easy integration of the sensor into existing process TOCeq and UVT.
control systems or external data logger. In addi-
LISA – Cutting-edge measurement technology at
eCHEM

tion to the integrated network interface, LISA UV is


low investment and operating costs.
available with digital or analog output. The sensor

Benefits Applications

• Without sampling and preparation of test • Sewage treatment plants


samples
• Environmental monitoring
Controller

• Real-time sensor
• Drinking water
• Without reagents
• Monitoring of UV-disinfection systems
• Optical window with nano coating
• LED technology

Path length Parameter Measuring range Detection limit


Dry Standards

SAC254nm* 0-1500 /m 5 /m
CODeq 0-2200 mg/L 8 mg/L
1 mm BODeq 0-700 mg/L 2.5 mg/L
TOCeq 0-880 mg/L 3 mg/L
UVT 3-100 % 98.8 %
SAC254nm* 0-150 /m 0.5 /m
Accessories

CODeq 0-220 mg/L 0.8 mg/L


10 mm BODeq 0-70 mg/L 0.25 mg/L
TOCeq 0-90 mg/L 0.3 mg/L
UVT 3-100 % 98.8 %

* following the DIN 38404 - C3 procedure


Systems

18 D02-000en202204 TriOS Catalogue


LISA UV // Photometer

Technical Specifications

Photometer
Measure­ light source 2 LED (254 nm, 530 nm)
ment tech­
nology detector Photo diode + filter
Measurement principle Attenuation, Transmission
Optical path 1 mm, 2 mm, 5 mm, 10 mm, 50 mm

Fluorometer
Parameter SAK254, CSBeq, BSBeq, TOCeq, UVT
Measuring range See parameter list
Measurement accuracy 0.2 % FS (Full Scale)
Turbidity compensation at 530 nm
Data logger ~ 2 MB

Radiometer
T100 response time 4s
Measurement interval ≥2s

Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035)


Dimensions (L x Ø) 300 mm x 48 mm (bei 10 mm Pfad) ~ 11.8” x 1.9” (with 10 mm path)
stainless steel ~ 2.3 kg (with 10 mm path) ~ 5.1 lbs (with 10 mm path)
Weight
titanium ~ 2.1 kg (with 10 mm path) ~ 4.6 lbs (with 10 mm path)

eCHEM
Ethernet (TCP/IP)
digital
RS-232 or RS-485 (Modbus RTU)
Interface
Ethernet (TCP/IP)
analog
4...20 mA
Power consumption ≤1W

Controller
Power supply 12...24 VDC (± 10 %)

Maintenance effort ≤ 0,5 h/month (typical)


Calibration/maintenance
24 months
interval
Modbus RTU
Dry Standards
System compatibility
or: Analog Out (4...20 mA)
Warranty 1 Jahr (EU: 2 years) US: 2 years

Installation
with SubConn 30 bar ~ 435 psig
Max. pres­
with fixed cable 3 bar ~ 43.5 psig
sure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig at 0.5 to 1.0 gpm
Accessories

Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Systems

D02-000en202204 TriOS Catalogue 19


Photometer // VIPER

VIPER
Photometer

17SXXXXX0
Fluorometer

VIPER measures spectrally resolved attenuation in drinking water. Like every TriOS sensor, VIPER
Radiometer

the wavelength range between 360 nm and 720 nm is equipped with nano-coated optical windows to
and thus allows the detailed determination of several prevent dirt build-up. Additional parameters can
parameters at the same time. 5 selected and energy- be installed later using software, if necessary.
saving LEDs serve as the light source, ensuring VIPER is equipped with the new TriOS G2 interface,
stable measurement data and a long service life. allowing easy and fast sensor configuration via a
VIPER can be used in a wide variety of media, as web browser. Integration into existing process control
it is available in several path lengths and in both systems and external data loggers has never been
stainless steel and titanium. Applications for VIPER easier.
eCHEM

include water monitoring, colour measurement


of aqueous solutions or quality monitoring of

NEW! The TriOS compressed air flushing is now also available for the paths 100 mm, 150 mm and 250 mm!

Advantages Applications
Controller

• without sampling and sample preparation • Drinking water monitoring

• without delay • Environmental monitoring

• without reagents • Colour measurement

• optical windows with nanocoating • Quality assurance

• LED technology • Petrochemistry


Dry Standards

• Industry
• Food industry
Accessories
Systems

20 D02-000en202204 TriOS Catalogue


VIPER // Photometer

Technical specifications

Photometer
light source 5 LED
Measure­
ment tech­ High-end miniature spectrometer, 256 channels
nology detector
360 to 750 nm, 2.2 nm/pixel
Measurement principle Attenuation

Fluorometer
Optical path 10 mm, 50 mm, 100 mm, 150 mm, 250 mm

SAC436
Pt-Co color scale (APHA/Hazen) (390 nm, 455 nm)
Parameter Colouring based on DIN EN ISO 7887-C
(410 nm, 436 nm, 525 nm, 620 nm)
Cr-Co color scale (380 nm, 413 nm)

Radiometer
Measuring range 0.01...2.5 AU (absorption units)
Measurement accuracy < 0.2 %
Turbidity compensation Yes
Data logger ~ 2 GB
T100 response time 2 min
Measurement interval ≥ 1 min

eCHEM
Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035)
Dimensions (L x Ø) 495 mm x 48 mm (with 50 mm path) ~ 19.5˝ x 1.9˝ (with 50 mm path)
stainless steel ~ 2.4 kg (with 50 mm path) ~ 5.3 lbs (with 50 mm path)
Weight
titanium ~ 1.3 kg (with 50 mm path) ~ 2.9 lbs (with 50 mm path)

Ethernet (TCP/IP)

Controller
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power consumption ≤3W
Power supply 12...24 VDC (± 10 %)

Maintenance effort ≤ 0.5 h/month (typical)


Calibration/maintenance
interval
24 months Dry Standards

System compatibility Modbus RTU


Warranty 1 year (EU: 2 years) US: 2 years

with SubConn 30 bar ~ 435 psig


Max. pres­
with fixed cable 3 bar ~ 43.5 psig
sure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1.0 gpm
Accessories

Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 ˚F to +104 ˚F


Ambient temperature +2...+40 °C ~ +36 ˚F to +104 ˚F
Storage temperature -20...+80 °C ~ -4 ˚F to +176 ˚F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Systems

D02-000en202204 TriOS Catalogue 21


Photometer // Colour Measurement

Colour Measurement
Photometer
Fluorometer
Radiometer
eCHEM

VIPER is an in-situ VIS spectrophotometer to determine the colour of liquids. In addition to the hyperspectral
recording of spectra (2.2 nm/pixel), various colour numbers can be determined. This enables standardized,
safe and objective measurements. Time-consuming and expensive sampling is eliminated by in-situ
measurements. What's more, variations over a whole day can be recorded.
Controller

SAC436 (DIN EN ISO 7887: 2012-04)


Spectral absorption coefficients at 436 nm are designated SAC436. It represents the light attenuation of an
aqueous sample with a layer thickness of 1 m and a wavelength of 436 nm. The yellow to brown colour
ranges that occur in coloured water have the highest light attenuation at 436 nm, which is why for example
the colouring is determined according to drinking water regulations at this wavelength.
VIPER compensates for any turbidity when determining SAC436.
Dry Standards

Depending on the customer's request, SACs in the entire wavelength range (such as SAC525, SAC620) can be
determined, or individual opacity adjustments can be made.

Pt-Co colour scale (Hazen/APHA)


(DIN EN ISO 6271:2016-05)
Accessories

The Pt-Co colour number records the range from colourless (<1) to light yellow to orange (500). The colour
number is defined via a standard solution of hexachloroplatinate in acidic salt water and specified in mg/L Pt.
The Pt-Co colour number is calculated using the turbidity corrected attenuation at 455 nm or 390 nm.
Systems

22 D02-000en202204 TriOS Catalogue


Colour Measurement // Photometer

Colouring

Photometer
VIPER enables hyperspectral measure-
ments of the colour of each liquid.
This also allows the differentiation of co-
lours that are perceived immediately, but
consist of different colour mixes.

Fluorometer
The diagram on the left shows examples
from the beverage industry.

VIPER: Attenuation spectrum

Radiometer
Subsequent calculation of colour ­numbers
is also possible thanks to the storage of
spectra. VIPER therefore enables several
colour numbers to be simultaneously
calculated from a spectrum. In addition
to the above colour numbers, the device
can determine the Cr-Co colour number

eCHEM
(Russian grade) in accordance with
GOST 3351-74, which is interesting for
the Russian market. Please contact us
for any special applications. We will be
happy to help.

Controller
Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 23


Photometer // LISA color

LISA color
Photometer

5XSXXXXX0
Fluorometer

Colorimetry – LISA enables reliable low-cost colour Equipped with our innovative G2 interface with a web
measurements. The LISA color uses two different browser configuration, internal data logger, flexible
LEDs for long-term stable measurement of the protocols and data outputs, the LISA color possess-
Radiometer

SAC or color at different wavelengths. The second es equipment attributes that are significantly greater
channel is used for turbidity/background correction. than the devices currently available on the market
The cutting-edge device platform, used in all other
The unified platform of all TriOS photometers also
TriOS photometers, enables optical path lengths
facilitates a standardized spare parts and consum-
of 50, 100, 150, and 250 mm, so that almost any
ables system, which means the broad range of our
application can be easily implemented.
device accessories can be implemented. The cut-
With the optional titanium housing, the LISA color ting-edge G2 interface also enables quick integration
can also be used for applications in aggressive into third-party systems.
eCHEM

media (e.g. high chloride concentrations).

NEW! The TriOS pressure cleaning is now available for the path lengths 100 mm, 150 mm and 250 mm!
Controller

Benefits Applications

• Low investment • Environmental monitoring


• Low maintenance (nano coating, air blast cle- • Drinking water monitoring
aning)
• Industrial applications
Dry Standards

• Simple integration into third-party systems


• Robust housing
Accessories
Systems

24 D02-000en202204 TriOS Catalogue


LISA color // Photometer

Technical Specifications

Photometer
Measurement Light source 2 LEDs
technology Detector Photodiode
Measurement principle Attenuation, transmission
Optical path 50 mm, 100 mm, 150 mm, 250 mm

SAC436, SAC525, SAC620

Fluorometer
Color (based on DIN EN ISO 7887 (410 nm, 436nm, 525 nm, 620 nm)
Parameters
Pt-Co color number (APHA/Hazen) (390 nm or 455 nm)
Cr-Co color number (380 nm or 413 nm)
Measurement range See parameter list p.26
Measurement accuracy 0.5 %

Radiometer
Turbidity compensation yes, 740 nm
Data logger ~ 2 MB
Reaction time T100 4s
Measurement interval ≥2s

Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035)


Dimensions (L x Ø) 340 mm x 48 mm (for 50-mm path) ~ 13.4” x 1.9” (for 50-mm path)

eCHEM
stainless steel ~ 2.4 kg (for 50-mm path) ~ 5.3 lbs (for 50-mm path)
Weight
titanium ~ 1.3 kg (for 50-mm path) ~ 2.9 lbs (for 50-mm path)
Ethernet (TCP/IP)
digital
RS-232 or RS-485 (Modbus RTU)
Interface
Ethernet (TCP/IP)
analog
4...20 mA

Controller
Power consumption ≤1W
Power supply 12...24 VDC (± 10 %)

Required supervision typically ≤ 0,5 hours per month


Calibration/maintenance
24 months
interval
Modbus RTU Dry Standards
System compatibility
Analog out (4...20 mA)
Warranty 1 year (EU & US: 2 years)

with Subconn 30 bars ~ 435 psig


Max. pres­
with fixed cable 3 bars ~ 43.5 psig
sure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Accessories

Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature +2...+40 °C ~ +36 °F to +104 °F
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Systems

D02-000en202204 TriOS Catalogue 25


Photometer // LISA color
Photometer

Measurement range

Measurement range
Parameters Unit
50 mm 100 mm 150 mm 250 mm
SAC 436 nm 1/m 0.1...30 0.05...15 0.03...10 0.02...6
SAC 525 nm 1/m 0.1...30 0.05...15 0.03...10 0.02...6
Fluorometer

SAC 620 nm 1/m 0.1...30 0.05...15 0.03...10 0.02...6


True color 410 nm mg/L Pt 2...560 1...280 0.6...185 0.4...110
Hazen 390 nm mg/L Pt 0.8...220 0.4...110 0.3...75 0.2...45
Hazen 455 nm mg/L Pt 4...1100 2...550 1.5...360 0.8...220
Cr-Co 380 nm ° (degree of color) 1...300 0.5...150 0.3...100 0.2...60
Cr-Co 413 nm ° (degree of color) 4...1100 2...550 1.5...360 0.8...220
Radiometer
eCHEM

150 mm 50 mm
Controller
Dry Standards
Accessories
Systems

26 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue
Sensor // Photometer

27
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Fluorometer // Sensor

28
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Fluorometer
Sensor // Fluorometer

29
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Fluorometer // enviroFlu

enviroFlu
Photometer

30SXXXXX0
Fluorometer

PAH, oil-in-water by means of UV fluorescence


enviroFlu-HC is a new generation of immersion waste water streams to environmental monitoring.
Radiometer

probes for measuring oil-in-water. The measuring The devices can be used stationary in manholes, in
principle of UV fluorescence used is far more the flow or in pipelines, as well as portable, using
sensitive than the conventionally used infrared an optional hand-held measuring device. A new type
scattering or absorption methods. This makes it of coating reduces soiling of the optical measuring
possible to determine even the smallest traces of windows and thus reduces the required maintenance
PAHs, e.g. in drinking water, but also in cooling water to a minimum.
condensates. The field of application ranges from
petrochemistry, leakage detection in cooling and
eCHEM

Advantages Areas of application

• without sampling and sample preparation • Drinking water

• without delay • Waste water

• without reagents • Airports


Controller

• high sensitivity and selectivity • Cooling water


• optical windows with nanocoating • Desalination plants
• Refineries
NEW! enviroFlu HC MB incl. Modbus interface! • Pipeline monitoring
• Bilge water monitoring
Dry Standards

• Flue gas scrubbing with ship approval


according to MEPC.259(68)

Interface Data protocol Variants Measuring range

Digital: RS-232 TriOS HC 500 0...500 ppb


enviroFlu HC
Analog: 4...20 mA / 0...5 VDC Data protocol HC 5000 0...5000 ppb
Accessories

HC MB 500 0...500 ppb


enviroFlu HC MB Digital: RS-485 Modbus RTU
HC MB 5000 0...5000 ppb

Digital: RS-232 TriOS


enviroFlu BT BT 0...10 000 ppb
Analog: 4...20 mA / 0...5 VDC Data protocol
Systems

30 D02-000en202204 TriOS Catalogue


enviroFlu // Fluorometer

Technical specifications

Photometer
Measurement Light source Xenon flash lamp + filter (254 nm)
­technology Detector Photodiode + filter (360 nm)
Measurement principle Fluorescence

Parameters PAH, oil

Fluorometer
enviroFlu HC PAH: 0...50 ppb, 0...500 ppb,
Measure­ (MB) 500 Oil: 0...1.5 ppm, 0...15 ppm typ.
ment enviroFlu HC PAH: 0...500 ppb, 0...5000 ppb
range (MB) 5000 Oil: 0...15 ppm, 0...150 ppm typ.
enviroFlu BT 0...1000 ppb, 0...10 000 ppb
enviroFlu HC (MB) 500 0.3 ppb
Detection limit

Radiometer
enviroFlu HC (MB) 5000 0.5 ppb
Measurement accuracy ± 5 % FS*
Reproducibility ≤ 0.5 % FS*
Turbidity compensation No (only possible via TTurb on the TriBox3)
Data logger no
Reaction time T100 ≤ 10 s

eCHEM
Measurement interval ≥5s

Digital: RS-232 (TriOS Protocol)


enviroFlu HC
Analog: 4...20 mA, 0...5 V
Digital: RS-485 (Modbus RTU)
Interface enviroFlu HC MB
Analog: nicht vorhanden
Digital: RS-232 (TriOS Protocol)
enviroFlu BT

Controller
Analog: 4...20 mA, 0...5 V
Power consumption ≤ 3.5 W
Power supply 12...24 VDC (± 10 %)

Required supervision Typically ≤ 0.5 h/month


Calibration/maintenance 24 months, the manufacturer calibration can be increased to 4-5 years
interval when used with associated DryCAL-Set Dry Standards
System compatibility analog out (0...5 VDC, 4...20 mA)
Warranty 1 year (EU: 2 years) US: 2 years

Stainless steel (1.4571/1.4404) or titanium (3.7035)


Housing
DeepSea version: titanium (3.7035)
Material black POM with synthetic quartz glass
Measuring head DeepSea version: Cover titanium, pressure ring POM
Accessories

Acid-resistant version: PPS


311 mm x 68 mm ~12.2˝ x 2.6˝
Dimensions (L x Ø)
DeepSea version: 314 x 78 mm Deep sea version: ~ 12.4˝ x 3.1˝
stainless steel ~ 2.7 kg ~ 6 lbs
Weight ~ 1.9 kg ~ 4.2 lbs
titanium
DeepSea version: ~ 3.9 kg DeepSea version: ~ 8.6 lbs
Systems

D02-000en202204 TriOS Catalogue 31


Fluorometer // enviroFlu
Photometer

with SubConn 30 bars ~ 435 psig


Max. with fixed cable 3 bar ~ 43.5 psig
pressure in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Deepsea version 600 bar ~ 8702.2 psig
Protection type IP68 NEMA 6P
Fluorometer

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


-5...+55 °C ~ +23 °F to +131 °F
Ambient temperature (2...+40 °C for specified ac- (~ 32 °F to 104 °F for specified ac-
curacy) curacy)
Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Radiometer

300 m with SubConn 8-pin ~ 984 ft with SubConn 8-pin underwater


underwater connector connector
Max. immersion depth 30 m with fixed cable ~ 98.4 ft with fixed cable
optional: 6000 m Deepsea versi-
optional: ~ 19685.04 ft Deepsea version
on

* FS: Full Scale ≙ Measurement Range


eCHEM

Naphtalene Acenaphtylene Acenaphtene Fluorene Phenanthrene Anthracene


Controller

Fluoranthene Pyrene Benzo[a]anthracene Crysene Benzo[b]fluoranthene


Dry Standards

Benzo(k)fluoranthene Benzo[a]pyrene Dibenzo(a,h)anthracene Ideno(1,2,3-c,d)pyrene Benzo(g,h,i)perylene


Accessories
Systems

32 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue
Sensor // Fluorometer

33
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Fluorometer // nanoFlu

nanoFlu
Photometer

32SXXXXX0
Fluorometer

Miniature fluorometer

nanoFlu fluorometers are low-priced, submersib- as well as in drinking and wastewater treatment sys-
Radiometer

le miniaturized fluorometers for the highly precise, tems. Internal reference signals of the high perfor-
selective measurement of cdom (coloured dissolved mance LEDs used for fluorescence excitation com-
organic matter, yellow substances), chlorophyll a, pensate ageing effects and temperature influences.
phycocyanin in cyanobacteria, rhodamine or fluore-
The nanoFlu features the new TriOS G2 interface,
scein. Long-term stability of measurements is ensu-
allowing fast and easy configuration of sensors
red by the combination of low power consumption
by using a web browser. Integration into existing
and innovative coating of the optical window, as an
process control systems and external data loggers
energy efficient and environmentally friendly antifou-
has never been easier.
ling solution. The devices can be used in diverse ap-
eCHEM

plications for the monitoring of sea and river waters,

Benefits Applications

• High sensitivity • Surface water

• Nano-coating • Bathing lakes


Controller

• Fast data acquisition • Drinking water production and treatment

• Electronic light compensation • Raw water treatment

• Compact size • Environmental monitoring

• Low power consumption


Accessories
Dry Standards

• Low costs
• FlowCell
• SolidCAL

Parameter list
Accessories

cdom [µg/L] with 0...200 µg/L


or chlorophyll a [µg/L] with 0...200 µg/L or 0...500 µg/L
Parameters or phycocyanin [µg/L] with 0...200 µg/L or 0...500 µg/L
or rhodamine [µg/L] with 0...200 µg/L
or fluorescein [µg/L] with 0...200 µg/L
Systems

34 D02-000en202204 TriOS Catalogue


nanoFlu // Fluorometer

Technical Specifications

Photometer
Measurement Light source LED
technology Detector Photodiode
Measurement principle Fluorescence

Parameters See parameter list

Fluorometer
Measurement range 0...200 µg/L or 0...500 µg/L
Measurement accuracy ±5%
Turbidity compensation no
Data logger no
Reaction time T100 6s

Radiometer
Measurement interval 3s
Stainless steel (1.4571/1.4404) or
Housing material titanium (3.7035) or
POM
Dimensions (L x Ø) 171 mm x 36 mm
stainless steel 0.5 kg
Weight
titanium 0.4 kg

eCHEM
POM 0.27 kg

Ethernet (TCP/IP)
Interface digital
RS-232 or RS-485 (Modbus RTU)
Power con­ typical <1W
sumption with network < 1.6 W

Controller
Power supply 12...24 VDC (± 10 %)

Required supervision typically ≤ 0,5 hours per month


Calibration/maintenance interval 24 months
System compatibility Modbus RTU
Warranty 1 year (EU & US: 2 years) Dry Standards

Installation
with SubConn 30 bars
Max. pressure with fixed cable 3 bars
in FlowCell 1 bar, 2...4 L/min
Protection type IP68
Accessories

Sample temperature +2...+40 °C


Ambient temperature +2...+40 °C
Storage temperature -20...+80 °C
Inflow velocity max. 10 m/s
Systems

D02-000en202204 TriOS Catalogue 35


Fluorometer // matrixFlu VIS

matrixFlu VIS
Photometer

34S10XXXX
Fluorometer

Our high-end matrixFlu VIS fluorometer combines sured values is increased by an internal temperature
multiple excitation and detection wavelengths for flu- correction.
orescence meas­urements in a single device with a
Equipped with our innovative G2 interface with web
highly compact design. The special optical arrange-
Radiometer

browser configuration, internal data logger, flexible


ment of excitation and detection channels enables
protocols and data outputs, matrixFlu offers exten-
not only single values to be determined, but also a
sive features that go significantly beyond what's
4x4 matrix of wavelength combinations. This allows
available on the market today.
quasi synchronous in-situ detection of EEMs (Exci-
tation Emission Matrices). The unified platform of all TriOS photometers also
facilitates a standardized spare parts and consum-
MatrixFlu VIS is primarily designed for the online de-
ables system, which allows the use of a wide range
tection of algae (cyanobacteria, green algae, etc.)
of accessories for our devices. Furthermore the cut-
eCHEM

and is expanded by the detection of cdom.


ting-edge G2 interface enables quick integration into
State-of-the-art, specially selected LEDs are used third-party systems.
for fluorescence excitation. The stability of mea-

Benefits

• Without sampling and preparation of test


Controller

samples
• Real-time sensor
• Without reagents
• Optical window with nano coating
Dry Standards

Applications

• Surface water
• Bathing lakes
• Drinking water production and treatment
• Raw water treatment
Detail of design for 4x4 wavelengths
• Environmental monitoring
Accessories

Em
Ex 460 682 655 850

375 cdom 1 cdom 3 cdom 2 XX3


470 scat 460 chl-a XX2 XX4
The development was part of the NEXOS project
and was funded by the European Union. 590 XX1 blue2 blue1 XX5
Systems

36 D02-000en202204 TriOS Catalogue


matrixFlu VIS // Fluorometer

Technical Specifications

Photometer
Measure­ light source 3 LED (375 nm/470 nm/590 nm)
ment tech­
nology detector 4 photo diodes with filter
Measurement principle Fluorescence

Fluorometer
Chlorophyll a [µg/L]
Parameter Phycocyanin [µg/L]
cdom [µg/L]
Measuring range 0...200 µg/L 0...200 ppb
Measurement accuracy 5%
Turbidity compensation Yes

Radiometer
Data logger ~ 10 MB
T100 response time 12 s
Measurement interval 6s

Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035)


Dimensions (L x Ø) 155 mm x 36 mm ~ 6.1˝ x 1.4˝
stainless steel ~ 0.6 kg ~ 1.3 lbs

eCHEM
Weight
titanium ~ 0.5 kg ~ 1.1 lbs

Ethernet (TCP/IP)
Interface digital
RS-232 oder RS-485 (Modbus RTU, OGC PUCK)
Power consumption ≤ 1.8 W
Power supply 12...24 VDC (± 10 %)

Controller
Maintenance effort ≤ 0.5 h/month (typical)
Calibration/maintenance
24 months
interval
System compatibility Modbus RTU, OGC PUCK
Warranty 1 year (EU: 2 years) US: 2 years
Dry Standards
Installation
with SubConn 30 bar ~ 435 psig
Max. pres­
with fixed
sure 3 bar ~ 43.5 psig
cable
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Accessories

Ambient temperature +2...+40 °C ~ +36 °F to +104 °F


Storage temperature -20...+80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...5 m/s ~ 0.33 fps to 16.4 fps
Systems

D02-000en202204 TriOS Catalogue 37


Fluorometer // microFlu V2

microFlu V2
Photometer

37SX0XX1X
Fluorometer
Radiometer

microFlu V2 fluorometers are submersible miniature fluorometers for highly precise and selective measurement
of tryptophan, cdom, blue-green algae or chlorophyll. The combination of low power consumption and
innovative coating of the measurement windows as an energy and environmentally neutral antifouling solution
ensures long-term stability of the measurements. The instruments can be used in a wide range of applications
for monitoring seawater, river water, drinking water and wastewater. Internal reference measurements of the
high-power LED used for fluorescence excitation compensate for aging effects and temperature influences.
microFlu V2 is equipped with a RS-485 interface, which enables allows easy and fast sensor configuration via
Modbus. Integration into existing process control systems and external data loggers has never been easier.
eCHEM

Advantages Applications

• without sampling and sample preparation • Surface waters


• without delay • Bathing lakes
Controller

• without reagents • Drinking water treatment


• high sensitivity and selectivity • Raw water treatment
• optical windows with nanocoating • Environmental monitoring
• electronic daylight compensation
• handy size
Dry Standards

Sensor Version Parameter Ex / Em Measuring range Detection limit


chl Chlorophyll 470 nm / 685 nm 0 – 200 ppb 0.05 ppb
chl Chlorophyll 470 nm / 685 nm 0 – 500 ppb 1 ppb
Accessories

blue Cyanobacteria 620 nm / 655 nm 0 – 200 ppb 0.5 ppb


blue Cyanobacteria 620 nm / 655 nm 0 – 500 ppb 2 ppb
cdom
cdom (coloured dissolved 375 nm / 460 nm 0 – 500 ppb 0.25 ppb
organic mater)
TRP Tryptophan 275 nm / 360 nm 0 – 500 ppb 3 ppb
Systems

38 D02-000en202204 TriOS Catalogue


microFlu V2 // Fluorometer

Technical specifications

Photometer
Measurement Light source LED + Filter
technology Detector Photodiode + Filter
Measurement principle Fluorescence
Chlorophyll a [µg/L]
Phycocyanin [µg/L]

Fluorometer
Parameters
cdom [µg/L]
Tryptophan [µg/L]
Measurement range See parameter list
Detection limits See parameter list
Measurement accuracy +/- (5 % + Detection limit)

Radiometer
Turbidity compensation No
Data logger No
Reaction time T90 6 s (default)
Smallest measuring interval 3 s (default)

digital RS-485, Modbus RTU


4...20 mA (default)
Interface

eCHEM
analog 0–5V
0 – 10 V
typical max. 0.6 W
Power con­ with activated
max. 1.1 W
sumption analog interface
Power-Down max. 70 mW

Controller
Power supply 12 – 24 VDC (± 10 %)

Required supervision ≤ 0.5 h/month typical


Calibration/
24 months
maintenance interval
Warranty 1 year (EU & USA 2 years)

Housing material Stainless steel (1.4571/1.4404) or titanium (3.7035) Dry Standards


Dimensions (L x Ø) ~ 162 mm x 48 mm ~ 6.4“ x 1.9“
VA ~ 650 g ~ 1.4 lbs
Weight
TI ~ 510 g ~ 1.1 lbs

with SubConn 30 bar ~ 435 psig


Max. pressure with fixed cable 3 bar ~ 43.5 psig
Accessories

in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm


Protection type IP68 NEMA 6P

Sample temperature + 2...+ 40 °C ~ +36 °F to +104 °F


Ambient temperature + 2...+ 40 °C ~ +36 °F to +104 °F
Storage temperature - 20...+ 80 °C ~ -4 °F to +176 °F
Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps
Systems

D02-000en202204 TriOS Catalogue 39


Fluorometer // microFlu V2 HC

microFlu V2 HC
Photometer

37S80XX13
Fluorometer
Radiometer

microFlu V2 HC is a new immersion probe for measuring oil in water. The measuring principle of UV
fluorescence used is many times more sensitive and specific than the conventionally used infrared scattering
or absorption methods. This makes it possible to determine even the smallest traces of PAHs, e.g. in drinking
water, but also in cooling water condensates. The field of application ranges from petrochemistry, leakage
detection in cooling and waste water streams to environmental monitoring. The instruments can be used
stationary in manholes or in flow-through, as well as in pipelines. A nano-coating reduces the contamination
of the optical measuring windows and thus reduces the required maintenance to a minimum.
microFlu V2 HC is equipped with an RS-485 interface that allows easy and fast sensor configuration via
eCHEM

Modbus and also has an analog interface. Integration with existing process control systems and external data
loggers has never been easier.

Advantages Applications

• without sampling and sample preparation • Surface waters


• without delay • Drinking water
Controller

• without reagents • Waste water


• high sensitivity and selectivity • Airports
• optical windows with nano-coating • Cooling water
• Desalination plants
Dry Standards

• Refineries / Gas stations


• Seepage ditch (road run-off water)
• Pipeline monitoring
• Bilge water monitoring

Technical specifications
Accessories

Measurement Light source LED 255 nm


technology Detector Photodiode + Filter (360 nm)
Measurement principle Fluorescence

Parameters PAH, Oil


Systems

40 D02-000en202204 TriOS Catalogue


microFlu V2 HC // Fluorometer

Photometer
PAH: 0...5000 ppb
Measurement range
Oil: 0...150 ppm typ.
PAH: 5 ppb
Detection limits
Oil: 0.15 ppm typ.
Measurement accuracy ±10 % FS
Turbidity compensation No

Fluorometer
Data logger No
Reaction time T90 6s
Smallest measuring interval 3s

digital RS-485, Modbus RTU


4...20 mA (default)

Radiometer
Interface
analog 0–5V
0 – 10 V
typical max. 0.6 W
Power con­ with activated
max. 1.1 W
sumption analog interface
Power-Down max. 70 mW

eCHEM
Power supply 12 – 24 VDC (± 10 %)

Required supervision ≤ 0.5 h/month typical


Calibration/maintenance interval 24 months
Warranty 1 year (EU & USA 2 years)

Housing material 1 year (EU & USA 2 years)

Controller
Dimensions (L x Ø) ca. 162 mm x 48 mm ~ 6.4“ x 1.9“
VA ~ 650 g ~ 1.4 lbs
Weight
TI ~ 510 g ~ 1.1 lbs

with SubConn 30 bar ~ 435 psig

Dry Standards
Max. pressure with fixed cable 3 bar ~ 43.5 psig
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P

Sample temperature + 2...+ 40 °C ~ +36 °F to +104 °F


Ambient temperature + 2...+ 40 °C ~ +36 °F to +104 °F
Storage temperature - 20...+ 80 °C ~ -4 °F to +176 °F
Accessories

Inflow velocity 0.1...10 m/s ~ 0.33 fps to 33 fps


Systems

D02-000en202204 TriOS Catalogue 41


D02-000en202204 TriOS Catalogue
Radiometer // Sensor

42
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Radiometer
Sensor // Radiometer

43
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Radiometer // RAMSES

RAMSES
Photometer

40SXXX010
Fluorometer

Spectral imaging radiometer to measure radiance or irradiance in UV, VIS and UV/VIS
RAMSES radiometers are spectral imaging radiometers to measure radiance, irradiance, or scalar irradiance
in the UV, VIS and UV/VIS ranges. Thanks to their ultra small size and weight as well as very low power
Radiometer

consumption, they are especially suitable for hand-held and autonomous applications. RAMSES radiome-
ters combine precision hyperspectral light measurements with a maximum of flexibility. The modular system
increases cost-effectiveness, while the many accessories and special solutions enable a wide range of appli-
cations such as installation on ships, handheld usage or autonomous measurements in remote places, like
the Arctic or Antarctica.

Benefits Applications
eCHEM

• Extremely low power consumption • Water quality

• Environmentally robust • Field measurements

• World market leader • Satellite validation


• Biology
• Photosynthesis
Controller

• Color measurements
• Climate research
Dry Standards
Accessories

Frame 1 Frame 2 Frame 3


Systems

44 D02-000en202204 TriOS Catalogue


RAMSES // Radiometer

Technical Specifications

Photometer
Measurement High-end miniature spectrometer
Detector
technology 256 Channels
Measurement Principle Radiance or irradiance

Parameter See parameter list p.46

Fluorometer
Measuring range See parameter list p.46
Measurement accuracy See parameter list p.46
T100 response time ≤ 10 s (burst mode)
Measurement interval ≤ 8 s (burst mode)

Housing material Stainless Steel (1.4571 / 1.4404) or Titanium (3.7035), POM


ACC 260 mm x 48 mm ACC ~ 10.2” x 1.9”

Radiometer
Dimensions without IP Module, without
ARC 300 mm x 48 mm ARC ~ 11.8” x 1.9”
SubConn Connector (L x Ø)
ASC 245 mm x 48 mm ASC ~ 9.6” x 1.9”
Dimensions with IP Modul, without ACC 284 mm x 48.5 mm ACC ~ 11.2” x 1.9”
connector ARC 322 mm x 48.5 mm ARC ~ 12.7” x 1.9”
Weight Titanium 1.25 kg ~ 2.8 lbs

Interface digital RS-232

eCHEM
Data logger -
Power consumption ≤ 0.85 W
Power supply 8...12 VDC (± 3 %)

Maintenance effort ≤ 0,5 h/month (typically)


Calibration-/Maintenance Interval 24 months
System compatibility RS-232 (TriOS Protocol)

Controller
Warranty 1 Year (EU & USA : 2 Years)

with SubConn 30 bar ~435 psig


Max. pressure
DeepSea version 100 bar ~1450 psig
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36…+104 °F Dry Standards


Ambient temperature +2...+40 °C ~ +36…+104 °F
Storage temperature -20...+80 °C ~ -4…+176 °F
Inflow velocity 0...10 m/s ~ 0…33 fps
Accessories
Systems

D02-000en202204 TriOS Catalogue 45


D02-000en202204 TriOS Catalogue
ACC ARC ASC

UV UV/VIS VIS VIS VIS

Wavelength range* [nm] 280...500 280...720 320...950 320...950 320...950


Detector* 256 Channel silicon photo diode array
Pixel dispersion* [nm/
2.2 2.2 3.3 3.3 3.3
pixel]
Wavelength accuracy* 0.2 0.2 0.3 0.3 0.3
Radiometer // RAMSES

Usable channels 100 200 190 190 190

ACC-UV ACC-VIS ARC-VIS ASC-VIS


UV A / UV B irradiance VIS irradiance VIS radiance VIS scalar irradiance
Wavelength range* 280...500 nm 320...950 nm
RAMSES Parameter List

20 W m nm (at 300 nm)


-2 -1
10 W m nm (at 400 nm)
-2 -1
20 W m-2 nm-1 (at 400 nm)
Type Saturation
17 W m-2 nm-1 (at 360 nm) 8 W m-2 nm-1 (at 500 nm) 1 W m-2 nm-1 sr-1 (at 500 nm) 12 W m-2 nm-1 (at 500 nm)
(IT: 4 ms)**
18 W m-2 nm-1 (at 500 nm) 14 W m-2 nm-1 (at 700 nm) 15 W m-2 nm-1 (at 700 nm)
0.85 µW m nm (at 300 nm)
-2 -1
0.4 µW m-2 nm-1 (at 400 nm) 0.8 µW m-2 nm-1 (at 400 nm)
Type NEI**** (IT: 8 s) 0.75 µW m-2 nm-1 (at 360 nm) 0.4 µW m-2 nm-1 (at 500 nm) 0.25 µW m-2 nm-1 sr-1 0.6 µW m-2 nm-1 (at 500 nm)
0.80 µW m nm (at 500 nm)
-2 -1
0.6 µW m nm (at 700 nm)
-2 -1
0.8 µW m-2 nm-1 (at 700 nm)
Collector Kosinus FOV: 7° in air Spherical, 2 Pi
Accuracy Better than 6...10% *** Better than 6% *** Better than 5% ***
Integration time 4 ms...8 s

*) Specifications of Carl ZEISS AG, Germany **) Integration time ***) Depends on wavelength range ****) Noise-equivalent irradiance

46
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
RAMSES G2 // Radiometer

RAMSES G2

Photometer
40SXXX010

Fluorometer
Spectral imaging radiometer to measure radiance or irradiance in UV, VIS and UV/VIS
RAMSES radiometers are spectral imaging radiometers to measure radiance, irradiance, or scalar irradiance
in the UV, VIS and UV/VIS ranges. Thanks to their ultra small size and weight as well as very low power
consumption, they are especially suitable for hand-held and autonomous applications. RAMSES radiome-
ters combine precision hyperspectral light measurements with a maximum of flexibility. The modular system

Radiometer
increases cost-effectiveness, while many accessories and special solutions enable a wide range of applica-
tions such as installation on ships, handheld usage or autonomous measurements in remote places, like the
Arctic or Antarctica.
By implementing the G2 extension module, the RAMSES radiometry series now also features the innovative
G2 Interface and can now easily be configured by using a web-browser. The internal data logger with 2 GB
storage and the comparably low power consumption provides the opportunity for a self-sufficient measure-
ment operation without a separate controller. The addition of the Modbus RTU protocol to the interface sim-

eCHEM
plifies the integration into existing PLCs and external data loggers. Additional to radiance and irradiance, the
parameters inclination, pressure and temperature can be retrieved.

Controller
Dry Standards
Accessories

Benefits Applications

• Extremely low power consumption • Water quality • Photosynthesis


• Environmentally robust • Field measurements • Color measurements
• World market leader • Satellite validation • Climate research
• Biology
Systems

D02-000en202204 TriOS Catalogue 47


Radiometer // RAMSES G2
Photometer

Technical Specifications

Measurement High-end miniature spectrometer


Detector
technology 256 Channels
Measurement Principle Radiance or irradiance

Parameter See parameter list


Fluorometer

Measuring range See parameter list


Measurement accuracy See parameter list
T100 response time ≤ 24 s (burst mode)
Measurement interval ≤ 12 s (burst mode)

Housing material Stainless Steel (1.4571 / 1.4404) or Titanium (3.7035), POM


Radiometer

Dimensions with IP Modul, without ACC 284 mm x 48.5 mm ACC ~ 11.2” x 1.9”
connector ARC 322 mm x 48.5 mm ARC ~ 12.7” x 1.9”
Weight Titanium 1.25 kg ~ 2.8 lbs

Interface digital RS-485; Ethernet (TCP/IP)


Data logger ~ 2 GB
Power consumption typically 1 W
eCHEM

Power supply 9…24 VDC (± 10%)

Maintenance effort ≤ 0,5 h/month (typically)


Calibration-/Maintenance Interval 24 months
System compatibility RS-485 (Modbus RTU)
Warranty 1 Year (EU & USA : 2 Years)
Controller

with SubConn 30 bar ~435 psig


Max. pressure
DeepSea version 100 bar ~1450 psig
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36…+104 °F


Ambient temperature +2...+40 °C ~ +36…+104 °F
Dry Standards

Storage temperature -20...+80 °C ~ -4…+176 °F


Inflow velocity 0...10 m/s ~ 0…33 fps
Accessories
Systems

48 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue

RAMSES G2 Parameter Liste


ACC ARC ASC

UV UV/VIS VIS VIS VIS

Wavelength range* [nm] 280...500 280...720 320...950 320...950 320...950


Detector* 256 Channel silicon photo diode array
Pixel dispersion* [nm/
2.2 2.2 3.3 3.3 3.3

RAMSES G2 // Radiometer
pixel]
Wavelength accuracy* 0.2 0.2 0.3 0.3 0.3
Usable channels 100 200 190 190 190

ACC-UV ACC-VIS ARC-VIS ASC-VIS


UV A / UV B irradiance VIS irradiance VIS radiance VIS scalar irradiance
Wavelength range* 280...500 nm 320...950 nm
20 W m nm (at 300 nm)
-2 -1
10 W m nm (at 400 nm)
-2 -1
20 W m-2 nm-1 (at 400 nm)
Type Saturation
17 W m-2 nm-1 (at 360 nm) 8 W m-2 nm-1 (at 500 nm) 1 W m-2 nm-1 sr-1 (at 500 nm) 12 W m-2 nm-1 (at 500 nm)
(IT: 4 ms)**
18 W m-2 nm-1 (at 500 nm) 14 W m-2 nm-1 (at 700 nm) 15 W m-2 nm-1 (at 700 nm)
0.85 µW m nm (at 300 nm)
-2 -1
0.4 µW m-2 nm-1 (at 400 nm) 0.8 µW m-2 nm-1 (at 400 nm)
Type NEI**** (IT: 8 s) 0.75 µW m-2 nm-1 (at 360 nm) 0.4 µW m-2 nm-1 (at 500 nm) 0.25 µW m-2 nm-1 sr-1 0.6 µW m-2 nm-1 (at 500 nm)
0.80 µW m nm (at 500 nm)
-2 -1
0.6 µW m nm (at 700 nm)
-2 -1
0.8 µW m-2 nm-1 (at 700 nm)
Collector Kosinus FOV: 7° in air Spherical, 2 Pi
Accuracy Better than 6...10% *** Better than 6% *** Better than 5% ***
Integration time 4 ms...8 s

*) Specifications of Carl ZEISS AG, Germany **) Integration time ***) Depends on wavelength range ****) Noise-equivalent irradiance
49

Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer


D02-000en202204 TriOS Catalogue
eCHEM // Sensor

50
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
eCHEM
Sensor // eCHEM

51
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
eCHEM // TpH

pH Sensor Digital TpH


Photometer

80S1000X0
Fluorometer

Robust digital pH sensor for operation on TriBox controllers and HS100 DIN G2 rail module. Digital communication
ensures safe and trouble-free signal transmission from the sensor to the controller. The high-quality gel pH electro-
de has a hole diaphragm and is insensitive to dirt, making the sensor ideal for wastewater applications.
Radiometer

Benefits Applications

• High-quality combination electrode with hole di- • Water and wastewater treatment
aphragm and polymerised solid electrolyte
• Coagulation and flocculation
• Low maintenance
• Process monitoring and control
• Plug and play with TriBox controller
• Acid/base neutralization systems
eCHEM

Accessories

• Cable: Extension cables of 0.3 m, 2 m, 10 m,


25 m
• Controller: TriBox3, TriBox mini, HS100
• Fittings: FlowCell
Controller

Technical Specifications

Measurement­ technology pH electrode


Measurement principle Potentiometry

Parameter pH value, temperature


Dry Standards

pH 0...14 pH
measuring range
Temperature 0...+65 °C
pH 0.01 pH
resolution
Temperature 0.1 °C
pH ± 0,06 pH
precision
Temperature ± 0.5 °C
Accessories

pH1 ± 0.05 pH
Intrinsic error pH7 ± 0.05 pH
pH13 ± 0.35 pH
Linearity measurement error ± 0.1 pH

The sensor complies with DIN EN 60746-2:2003-09 and the electrodes with BS 2586:1979.
Systems

52 D02-000en202204 TriOS Catalogue


TpH // eCHEM

Photometer
pH1 ± 0.1 pH
Repeatability pH7 ± 0.05 pH
pH13 ± 0.1 pH
Output signal pH7 ± 0.025 pH
fluctuation pH4 ± 0.05 pH
Warm-up time < 5 min

Fluorometer
Drift Short-term drift 24 h ≤ 0.03 pH
Long-term drift 1 week ≤ 0.05 pH
T10 ascending <2s
10% time and T10 falling <2s
90% time T90 ascending ≤5s

Radiometer
T90 falling ≤5s
Temperature compensation Pt1000
Measurement interval 2s

Housing material PPS / PET / NBR


Dimensions (L x Ø) ~ 180 x 27 mm ~ 7.1˝ x 1.1˝
Weight 110 g ~ 0.2 lbs

eCHEM
Interface RS-485, Modbus RTU
Power consumption 0.2 W
Power supply 12...24 VDC (± 10 %)
Connection 8-pin M12 plug
Sensor cable 2 m and 10 m

Controller
Required supervision Typically ≤ 0.5 h/month
Calibration / maintenance interval Typically 4 weeks
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics; wearing parts
Warranty
are excluded from the warranty

with fixed cable 3 bar ~ 43.5 psig Dry Standards


Max. pressure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Ambient temperature -5...+55 °C ~ +23 °F to +131 °F
Storage temperature 0...+80 °C ~ +32 °F to +176 °F
Accessories

Inflow velocity 0...3 m/second ~ 0...10 fps


Systems

D02-000en202204 TriOS Catalogue 53


eCHEM // TpH-D

pH Sensor Digital Differential TpH-D


Photometer

80S2000X0
Fluorometer

Robust, digital differential pH probe for operation with TriBox controllers and HS100 top-hat rail module. The
reference system of the pH electrode is separated from the measuring medium due to the closed design. This
Radiometer

rules out electrode poisoning. A salt bridge that is insensitive to dirt reduces the amount of cleaning required
and prevents dilution of the electrolyte. As a result, the probe achieves a particularly long service life even in
heavily contaminated media.TpH-D is available with a cable length of 10 m or 2 m.
Advantages Applications

• Communication of measurements via digital • difficult measurement of inlets to waste water


• Modbus RTU protocol treatment plants
eCHEM

• the differential measurement method enables • Process monitoring and control


a longer lifetime of the electrodes Accessories
• all calibrations can be performed via the digital
• Cable: Extension cable 0.3 m, 2 m, 10 m, 25 m
interface
• Controller: TriBox3, TriBox mini, HS100
• no moving mechanical parts
• Fittings: Flow cell
• plug and play with TriBox controller
Controller

Technical specifications

pH electrode with additional reference pH electrode in


Measurement technology
pH7 buffer solution
Measurement principle Potentiometry
Dry Standards

Parameters pH value, temperature


pH 0...14 pH
Measuring range
Temperature 0...+65 °C
pH 0.01 pH
Resolution
Temperature 0.1 °C
pH ± 0,06 pH
Accessories

Accuracy
Temperature ± 0.5 °C
pH1 ± 0.05 pH
Intrinsic error pH7 ± 0.05 pH
pH13 ± 0.35 pH

The sensor complies with DIN EN 60746-2:2003-09 and the electrodes with BS 2586:1979.
Systems

54 D02-000en202204 TriOS Catalogue


TpH-D // eCHEM

Photometer
Linearity measurement error ± 0.1 pH
pH1 ± 0.1 pH
Repeatability pH7 ± 0.05 pH
pH13 ± 0.1 pH
Output signal pH7 ± 0.025 pH
fluctuation pH4 ± 0.05 pH

Fluorometer
Warm-up time < 5 min
Drift Short-term drift 24 h < 0.03 pH
Long-term drift 1 week < 0.05 pH
T10 ascending <2s
10% time and T10 falling <2s

Radiometer
90% time T90 ascending ≤5s
T90 falling ≤5s
Temperature compensation Pt1000
Measurement interval 2s

PPS / PET / NBR / PVDF / ceramic junction / Viton


Housing material
O-ring / titanium ground electrode / pH glass
Dimensions (L x Ø) ~ 225 x 32 mm ~ 8.9˝ x 1.3˝

eCHEM
Weight 180 g ~ 0.4 lbs
Interface RS-485, Modbus RTU
Power consumption 0.2 W

Power supply 12...24 VDC (± 10 %)


Connection 8-pin M12 plug

Controller
Sensor cable 2 m and 10 m

Required supervision Typically ≤ 0.5 h/month


Calibration / maintenance interval Typically 4 weeks
System compatibility Modbus RTU
Warranty
1 year (EU&US: 2 years) on electronics; wearing parts Dry Standards
are excluded from the warranty

with fixed cable 3 bar ~ 43.5 psig


Max. pressure
in flow cell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P

Sample temperature +2...+40 °C ~ +36 °F to +104 °F


Accessories

Ambient temperature -5...+55 °C ~ +23 °F to +131 °F


Storage temperature +5...+15 °C ~ +41 °F to +59 °F
Inflow velocity 0...3 m/second ~ 0...10 fps
Systems

D02-000en202204 TriOS Catalogue 55


eCHEM // TTurb

Turbidity Sensor TTurb


Photometer

81SXX00XX
Fluorometer

The TTurb is a digital sensor for optical turbidity measurement using the 90° IR scattered light method. De-
pending on the sensor design it can be used in pure water up to 100 FNU as well as in raw water, waste water
and process water up to 1000 FNU. TTurb is available with different cable lengths (10 m or 2 m) as well as
Radiometer

in different versions.
As an immersion sensor, the TTurb can be used directly in the measuring medium, but is also available in the
FlowCell-optimized version directly with a flow cell for bypass applications. In addition, it is possible to obtain
the TTurb directly in a set with the dry-standard TTurbCAL. This standard is always directly adapted to each
individual instrument and thus enables precise function tests directly on site, without any reagents.
eCHEM

TTurb100 0...100 FNU


TTurb400 0...400 FNU
TTurb1000 0...1000 FNU

Benefits Applications
Controller

• Reliable concentration measurements by opti- • Measurement of turbidity in drinking water, do-


cal methods mestic water, circulating water
• Pulsed infrared scattered light procedure • Measurement of turbidity in drinking water
• No mechanically moving parts treatment plants with low turbidity values
Dry Standards

• Digital reading • Measurement of turbidity in open waters

• Preprocessing in the sensor increases measu-


rement sensitivity Accessories

• Cable: Extension cables of 0.3 m, 2 m, 10 m,


25 m
• Controller: TriBox3, TriBox mini, HS100
Accessories

• Fittings: FlowCell
• TTurbCAL
Systems

56 D02-000en202204 TriOS Catalogue


TTurb // eCHEM

Technical Specifications

Photometer
LED light source
Measurement ­technology
Photodiode detector
Measurement principle Nephelometry

Parameters Turbidity as FNU; mg/L; NTU; TSSeq

Fluorometer
Measuring range 0...100, 0...400, 0...1000 FNU
Measurement accuracy ± (5 % + 0.5)
0.5 FNU for TTurb 100
Detection limit 2 FNU for TTurb 400
2 FNU for TTurb 1000
Measurement wavelength 860 nm, FWHM 30 nm

Radiometer
Reaction time T100 6s
Measurement interval ≥3s

Housing material PET / POM / NBR


Dimensions (L x Ø) 170 x 36 mm ~ 6.7˝ x 1.4˝
Weight 0.3 kg ~ 0.7 lbs

eCHEM
Ethernet (TCP/IP)
Interface
RS-485 (Modbus RTU)
typically < 0.9 W
Power consumption
with network < 1.5 W
Power Supply 12...24 VDC (± 10 %)
Connection 8-pin M12 plug

Controller
Required supervision ≤ 0.5 h/month typically
Calibration/
24 months
maintenance interval
System compatibility Modbus RTU
1 year (EU&US: 2 years) on electronics;
Warranty
wearing parts are excluded from the warranty
Dry Standards
with fixed cable 3 bar ~ 43.5 psig
Max. pressure
in FlowCell 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1 gpm
Protection type IP68 NEMA 6P

Sample temperature 0...+40 °C ~ +32 °F... +104 °F


Ambient temperature 0...+40 °C ~ +32 °F... +104 °F
Accessories

Storage temperature 0...+80 °C ~ +32 °F... +176 °F


Inflow velocity maximum 0.1 m/second maximum ~ 0.33 fps

The sensor meets requirements of DIN EN ISO 7027-1:2016-11.


Systems

D02-000en202204 TriOS Catalogue 57


eCHEM // Conductivity

Conductivity Sensor
Photometer

90S4301X0
Fluorometer
Radiometer

Digital sensor to measure conductive conductivity especially in pure media, for operation on TriBox con-
trollers and HS100 DIN G2 rail module. The digital technology ensures secure and interference-free signal
transmission from the sensor to the controller.
eCHEM

Benefits Applications

• Reliable conductivity measurement with two • Measurement of conductivity in the outflow of


conductive graphite electrodes and tempera- wastewater treatment plants
ture compensation
• Measurement of conductivity in industrial and
Controller

• PVC sensor housing and graphite electrodes water circuits


• No mechanically moving parts
Accessories
• Immediate installation and easy maintenance
• Modbus RTU digital communication protocol • Cable: Extension cables of 0.3 m, 2 m, 10 m,
25 m
Dry Standards

• Controller: TriBox3, TriBox mini, HS100


• Fittings: FlowCell
Accessories
Systems

58 D02-000en202204 TriOS Catalogue


Conductivity // eCHEM

Technical Specifications

Photometer
Measurement ­technology Conductivity
Measurement principle Conductivity with two graphite electrodes

Parameters Conductivity

Fluorometer
Measurement range 0.00 µS… 20000 µS
±0.5 µS at 20 µS
± 5 µS at 200 µS
Measurement accuracy
± 50 µS at 2000 µS
± 500 µS at 20000 µS
Response time T90 < 60s

Radiometer
Temperature compensation Via NTC

Housing material PVC housing, graphite electrodes


Dimensions (L x Ø) 220 mm x 33 mm ~ 8.7“ x 1.3“

Interface RS-485 Modbus RTU


Power supply 12…24 VDC
Connection 8-pin M12 connector, cable length 2 m or 10 m

eCHEM
Maintenance interval 2 years
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty

Process pressure 10 bar ~ 145 psig

Controller
Calibration method One-point calibration with standard measuring solution

Process temperature 0…50°C ~ +32 °F to +122 °F

Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 59


eCHEM // Conductivity Inductive

Conductivity Inductive
Photometer

90S4401X0
Fluorometer
Radiometer
eCHEM

The inductive conductivity sensor has 2 toroidal coils which are housed in a plastic casing and therefore do
not come into contact with the surrounding solution. For this reason, it is physically impossible for the sensor
surface to become soiled, coated or contaminated.
Since the inductive conductivity sensor does not determine the conductivity via electrodes, but via electrical
fields, no polarization effects occur. Thus the sensor provides more accurate measurement results, especially
for measurement media with high conductivities.
Controller

The sensor housing is made of Noryl, which is extremely resistant to chemicals.

Benefits

• No contamination, coating or pollution of the


Dry Standards

sensor surface
• No polarization effects
• Low maintenance requirement
Accessories
Systems

60 D02-000en202204 TriOS Catalogue


Conductivity Inductive // eCHEM

Technical specifications

Photometer
Measurement technology Change of inductance
Measurement principle Change of inductance with two toroidal coils

Parameter Conductivity

Fluorometer
Measuring range 0.5 mS/cm – 2000 mS/cm
Measurement accuracy ± (2% + 20 μS/cm)
Drift 0.1 % / Year
Turbidity compensation No
Temperature compensation Via NTC

Radiometer
Data Logger No
Response time T90, depending on equilibrium
Measurement interval 10 seconds

Material Housing Noryl


Dimensions (L x Ø) 119 mm x 52 mm
Weight 0.1 kg

eCHEM
Interface RS-485 Modbus RTU (Baud rate = 9600)
Power consumption < 75 mW
Power supply 7 ‒ 40 VDC
Connection 8-pin M12 connector
Maintenance effort ≤ 0.5 h/month typical

Controller
Maintenance interval 24 Months
Two-point calibration in air and with standard measuring solution during
Calibration method
initial installation, followed by validation
System compatibility Modbus RTU
Warranty 1 year, EU & USA: 2 years
Dry Standards

Max. pressure With fixed cable 10 bar


Protection type IP68
Sample -10 °C ... +70 °C (max. 85 °C)
Temperature Ambient -10 °C ... +70 °C (max. 85 °C)
Storage -20 °C ... +80 °C
Accessories

Inflow velocity Max. 3 m/s, Steady and constant flow


Systems

D02-000en202204 TriOS Catalogue 61


eCHEM // Dissolved Oxygen

Digital Dissolved Oxygen Sensor


Photometer

90S53X1X0
Fluorometer
Radiometer

The oxygen sensor uses luminescence-based optical measurement technology and measures reliably and
precisely. The low maintenance and small amount of consumable materials needed by the sensor provide
immediate returns on investment. Only the membrane cap must be replaced every two years. The sensor
can also be used in applications with a very weak water flow. The oxygen sensor is available with a 10-meter
or a 2-meter cable.
eCHEM

Benefits Applications

• Low operation costs thanks to low maintenance • Measurement of dissolved oxygen in surface
(no electrolyte replacement)
Controller

water, aquaculture, seawater and drinking wa-


• Larger calibration interval thanks to low devi- ter and wastewater plants
ations
• No polarisation voltage necessary Accessories
• High degree of measurement accuracy, even at • Cable: Extension cable 0.3 m, 2 m, 10 m, 25 m
low concentrations
Dry Standards

• Controller: TriBox3, TriBox mini, HS100


• Fast response time
• Fittings: FlowCell
• No minimum inflow (no oxygen consumption)
Accessories
Systems

62 D02-000en202204 TriOS Catalogue


Dissolved Oxygen // eCHEM

Technical Specifications

Photometer
Measurement principle Luminescence

Parameters Dissolved oxygen


0...20 mg/L
Measurement range 0...20 ppm

Fluorometer
0...200 %
± 0.1 mg/L
Measurement accuracy ± 0.1 ppm
±1%
Resolution 0.01
Reaction time 90% of the value in less than 60 seconds
Measurement interval >5s

Radiometer
Inflow velocity No movement necessary
Temperature compensation Via NTC (compensation active for temperatures below 0 °C)
Measurement range (tem­
0...+50 °C
perature)
Resolution (temperature) 0.01 °C
Accuracy (temperature) 0.5 °C
No cross-sensitivity with: pH 1...14 ; CO2, H2S, SO2

eCHEM
Membrane cap Cross-sensitivity with organic solvents such as acetone, toluene, chloro-
form dichloromethane (methylene chloride) or chlorine gas
Standard version with passivated stainless steel (316L) housing, cap and
screws; For seawater applications with titanium housing, cap and screws
Material Cable: polyurethane casing; Cable grommet: polyamide
Patch with active substance (black) - membrane: silicon for optical insu-

Controller
lation
Dimensions (L x Ø) 146 mm x 25 mm ~ 5.7˝ x 1˝
stainless steel ~ 450 g ~ 1 lbs
Weight
titanium ~ 300 g ~ 0.7 lbs

Interface RS-485 (Modbus RTU)


Power consumption 1W Dry Standards
Power supply 12 V (± 10 %)
Sensor cable 2 m and 10 m ~ 6.6 ft and ~ 32.8 ft

Calibration/maintenance
2 years
interval
1 year (EU & US: 2 years) on electronics; wear parts are excluded from the
Warranty
warranty
Accessories

Max. pressure 5 bar ~ 72.5 psig


Protection type IP 68 NEMA 6P

Sample temperature 0...+50 °C ~ +32 °F... +122 °F


Ambient temperature 0...+50 °C ~ +32 °F... +122 °F
Storage temperature -10...+60 °C ~ +14 °F... +140 °F
Systems

D02-000en202204 TriOS Catalogue 63


eCHEM // Free Chlorine

Free Chlorine Sensor Digital


Photometer

90S21000X
Fluorometer
Radiometer

The chlorine sensor from the eCHEM sensors product range is an electrochemical sensor for measuring the
chlorine concentration in water. This sensor detects free chlorine from inorganic chlorine products (chlorine
gas, hypochlorite, etc.). The measuring method has a reduced pH dependency, so that pH fluctuations only
have a limited impact on the measurement signal. pH value increases only lead to an approximately 10%
reduction of the measuring signal per pH unit.
eCHEM

Benefits Applications

• Stable signals even with fluctuating pH values • Swimming pools, drinking water, seawater
• Abrasive particles are tolerated
Controller

• Surfactants are partially tolerated Accessories

• Cable: Extension cables of 0.3 m, 2 m, 10 m, 25 m


• Controller: TriBox3, TriBox Mini, HS100
• Fittings: FlowCell
Dry Standards
Accessories
Systems

64 D02-000en202204 TriOS Catalogue


Free Chlorine // eCHEM

Technical Specifications

Photometer
Measurement technology Membrane-covered, amperometric potentiostatic 3-electrode system
Measurement principle Amperometry

Parameters Free chlorine with reduced pH dependency

Fluorometer
Measurement range 0...2 mg/L, 0...20 mg/L

Measuring range 2 mg/L:


at 0.4 mg/L & 1.6 mg/L < 1%
Accuracy Measuring range 20 mg/L:
at 4 mg/L < 1%
at 16 mg/L< 3 %

Radiometer
Response time T90: approx. 2 min

Running-in period Approx. 2 h prior to initial operation

Drift approx. -1 % per month


Temperature compensa­ Automatic through integrated temperature sensor; Temperature jumps must
tion be avoided

eCHEM
Housing material Micro-porous hydrophilic membrane, UPVC, stainless steel 1.4571
Dimensions (L x Ø) Approx. 205 mm x approx. 25 mm ~ 8.1” x 1”

Interface RS-485, Modbus RTU


Power supply 9...30 VDC
Connection 8-pin M12 plug

Controller
Maintenance interval typically once per week
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty

1 bar, no pressure shocks or vibra-


Process pressure ~ 14.5 psig
tions, with retaining ring Dry Standards
Calibration method Determination of chlorine with DPD-1 method
0...+45 °C (no ice crystals in the test
Process temperature ~ +32 °F... +113 °F
water)
Flow rate Approx. 15...30 L/h in FLC-3, minimum flow dependence exists
pH range pH 4...pH 9, reduced pH dependence
Conductivity 10 μS/cm...50 mS/cm (sea water)
Accessories

Cross influences Combined chlorine increases measured value


Systems

D02-000en202204 TriOS Catalogue 65


eCHEM // Chlorine Dioxide

Chlorine Dioxide Sensor Digital


Photometer

90SX20000
Fluorometer
Radiometer

The chlorine dioxide sensor from the eCHEM sensors product range is an electrochemical sensor for meas-
uring the chlorine dioxide concentration in water. The range of application of the sensor covers almost all wa-
eCHEM

ter qualities and treatments (e.g. bottle washing machine, CIP system, rinser). It can also be used in seawa-
ter. Thanks to a special membrane system, the sensor is particularly resistant to chemicals and surfactants.

Benefits Applications
Controller

• Surfactants are partially tolerated • All types of water treatment


• Abrasive particles are tolerated
• Higher temperatures are possible
Accessories

• Cable: Extension cables of 0.3 m, 2 m, 10 m, 25 m


Dry Standards

• Controller: TriBox3, TriBox Mini, HS100


• Fittings: FlowCell
Accessories
Systems

66 D02-000en202204 TriOS Catalogue


Chlorine Dioxide // eCHEM

Technical Specifications

Photometer
Measurement technology Membrane-covered, amperometric 2-electrode system
Measurement principle Amperometry

Parameters Chlorine Dioxide

Fluorometer
Measurement range 0...2 mg/L, 0...20 mg/L
Measuring range 2 mg/L:

at 0.4 mg/L & 1.6 mg/L < 1 %


Accuracy
Measuring range 20 mg/L:

at 1.5 mg/L < 0.1 %

Radiometer
Response time T90: approx. 1 min

Running-in period Approx. 2 h prior to initial operation

Drift Approx. -1 % per month


Temperature compensa­ Automatic through integrated temperature sensor; Temperature jumps must
tion be avoided

eCHEM
Housing material Micro-porous hydrophilic membrane, UPVC, stainless steel 1.4571
Dimensions (L x Ø) Approx. 205 mm x approx. 25 mm ~ 8.1” x 1”

Interface RS-485, Modbus RTU


Power supply 9...30 VDC, max. 56 mA
Connection 8-pin M12 plug

Controller
typically once a week measuring signal check,
Maintenance interval
membrane cap change & electrolyte change depending on application
System compatibility Modbus RTU
1 year (EU & US: 2 years) on electronics;
Warranty
wear parts are excluded from the warranty

1 bar, no pressure shocks or vibra- Dry Standards


Process pressure ~ 14.5 psig
tions, operation with retaining ring
Calibration method Determination of chlorine with DPD-1 method
0...+50 °C (no ice crystals in the test
Process temperature ~ +32 °F...+122 °F
water)
Flow rate Approx. 15...30 L/h in FLC-3, minimum flow dependence exists
Accessories

pH range pH 1...pH 12, reduced pH dependence


Conductivity 10 μS/cm...50 mS/cm (sea water)
Cross influences Cl2 does not interfere; O3: factor 25
Systems

D02-000en202204 TriOS Catalogue 67


eCHEM // Total Chlorine

Total Chlorine Sensor


Photometer

90SX30000
Fluorometer
Radiometer

The chlorine sensor from the eCHEM sensor product range is an electrochemical sensor for measuring the
chlorine concentration in water. The sensor measures the concentration of total chlorine in a sample created
by adding inorganic chlorine products (e.g. chlorine gas, sodium hypochlorite solution, calicium hypochlorite
solution). The measuring method has a reduced pH dependency, so that pH value fluctuations only have a
minor influence on the measuring signal. By regularly replacing the electrolyte and the membrane cap, the
sensor performance can be guaranteed and ensured over a longer period of time.

Advantages
eCHEM

Applications

• Stable signals even with variable pH values • Swimming pools, drinking water, seawater,
brine water (15% NaCl)
• Surfactants are partially tolerated
Accessories

• Cable: Extension cable 0.3 m, 2 m, 10 m, 25 m


Controller

• Controller: TriBox3, TriBox Mini, HS100


• Fittings: FlowCell

Technical specifications
Dry Standards

Measurement technology Membrane-covered, amperometric potentiostatic 3-electrode system


Measuring principle Amperometry

Total chlorine (free chlorine + combined chlorine) with reduced pH


Parameter
dependence
Measurement range 0...2 mg/L; 0...20 mg/L
Measuring range 2 mg/L: <2% at 0.4 mg/L and 1.6 mg/L
Accuracy*
Accessories

Measuring range 20 mg/L: <1% at 4 mg/L and <3% at 16 mg/L


Swimming pools, drinking water, seawater, brine water (15% NaCl),
Application
Surfactants are partially tolerated
Inorganic chlorine compounds:
Suitable chlorinating agents NaOCl (=chlorine bleach), Ca(OCl)2, chlorine gas, electrolytically
produced chlorine
Systems

68 D02-000en202204 TriOS Catalogue


Total Chlorine // eCHEM

Photometer
Measuring range 2 mg/L: 0.001 mg/L
Resolution
Measuring range 20 mg/L: 0.01 mg/L
Response time T90: approx. 3 minutes (brine water approx. 5 minutes)
Running-in time Approx. 2 hours for initial start-up
Slope drift approx. -1 % per month
Automatically, through an integrated temperature sensor, tempera-
Temperature compensation
ture jumps are to be avoided

Fluorometer
pH range pH 4 - pH 12, with reduced pH dependence
Conductivity 10 µS/cm - 200 µS/cm (brine water)
Zero point determination Not necessary
On the unit by analytical chlorine determination, DPD-4 method
Slope calibration
(DPD-1 + DPD-3)
ClO2: factor 1; O3: factor 1.3;

Radiometer
Cross-sensitivities Corrosion inhibitors and water hardness stabilisers can cause meas-
urement errors.
Absence of the disinfectant Max. 24 hours

Microporous hydrophilic membrane, PVC-U, PEEK, stainless steel


Material
(1.4571)
Dimensions (L x Ø) approx. 205 mm x 25 mm

eCHEM
Weight 1.1 kg

Interface RS-485, Modbus RTU


Power supply / electronics** 9 - 30 VDC, approx. 56 - 20 mA
Connection 8-pin M12 connector

Weekly control of the measuring signal recommended

Controller
Maintenance effort Depending on the water quality, the membrane cap and the electro-
lyte should be replaced once a year
System compatibility Modbus RTU
1 year (EU & USA: 2 years) on electronics;
Warranty
Wear parts are excluded from the warranty

Max. Pressure 3 bar, no pressure surges and/or vibrations, with circlip


Dry Standards
Inflow velocity approx.15 - 30 l/h in FlowCell
Transport +5...+50 °C (sensor, electrolyte, membrane cap)
Temperature Sample 0...+45 °C (there must be no ice crystals in the measuring water)
Ambient 0…+55 °C
can be stored dry and without electrolyte for an unlimited period at
Sensor
+5...+40 °C
Accessories

in original container in the dark at +5...+ 35 °C one year (after pro-


Storage Electrolyte
duction, please note expiry date)
Can be stored in original packaging for an unlimited period at
Membrane cap
+4...+40°C (used caps cannot be stored).

* After calibration at repeat conditions (25 °C, pH 7.2 in drinking water) from full scale value
** Electronics is completely electrically isolated; digital internal measured value processing
Systems

D02-000en202204 TriOS Catalogue 69


D02-000en202204 TriOS Catalogue
COntroller // Sensor

70
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Controller
Sensor // Controller

71
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
COntroller // TriBox3

TriBox3
Photometer

10C000000
Fluorometer

Digital 4-channel display and control unit with integrat-


ed solenoid valve for compressed air control
TriBox3 is a measurement and control system for all
TriOS sensors. The unit offers 4 sensor channels with
selectable RS-232 or RS-485 interface. In addition to
Modbus-RTU, various other protocols are available. A can be used to trigger alarms or control external de-
Radiometer

built-in valve allows the use of a compressed air purge vices. Low power consumption, a robust aluminium
for the sensors. In addition, the TriBox3 offers various housing and a range of interfaces make the TriBox3
interfaces, including an IEEE 802.3 Ethernet interface, ideal for all applications in environmental monitoring,
an IEEE 802.11 b/g/n interface, a USB connection and drinking water, waste water treatment plants and many
6 analogue outputs (4...20 mA). An integrated relay other areas.
Advantages • WiFi for communication

• open Modbus RTU communication • USB interface


eCHEM

• for all digital TriOS sensors • TCP/IP interface

• cost-effective alternative to analogue measuring • Modbus RTU server


points • also available without WiFi
• integrated data logger with service logbook

Technical specifications
Controller

Power supply
Voltage supply 100...240 VAC, 50...60 Hz, 12...24 VDC (± 5%)
Power consumption Type: 6 W, max: 50 W
Protection class 1
Overvoltage category II
Dry Standards

Sensor interfaces
Connection 4 M12 industrial connectors for TriOS sensors
Standard RS-232, RS-485
Protocol Modbus-RTU, TriOS
Modbus RTU
Server RTU yes (on each sensor connector)
Accessories

Client RTU yes (on each sensor connector)


Parameters Adjustable (default: 9600-8-N-1)
Modbus TCP
Server TCP yes
TCP port Adjustable (default: 502)
Systems

72 D02-000en202204 TriOS Catalogue


TriBox3 // Controller

Photometer
Network/USB
Standard Ethernet, WiFi based on IEEE 802.11b/g/n
Connection 1 RJ-45 integrated WiFi antenna (for TriBox3 with WiFi)
Protocol TCP/IP, Modbus TCP, VNC
Web interface no
USB USB 2.0 (Host), USB-A socket

Fluorometer
Analog interfaces
Analog Output 6 analogue outputs, configurable: 4...20 mA
Load max. 500 Ω
Connection terminals 1.5 mm² 16 AWG
Error indicator 0 mA

Radiometer
Switch input/output
Trigger for global measurement (galvanically isolated),
Control voltage: 12...24 VDC (± 5%)
Measurement trigger Control voltage: 12...24 VDC (± 5%)
Connection terminal: 1.5 mm² (AWG
Connection terminal: AWG 16
16)
Control voltage no

Relay outputs

eCHEM
Electrical specification 1 x relay changeover contact (SPDT) / 250 VAC, 2 A / 30 VDC, 2 A
Connection terminals max. 2.5 mm² max. 14 AWG

Compressed air cleaning


Valve integrated, max. air pressure: 5 bar

Display

Controller
Display 7” capacitive touch-display (800x480 pixels)
LED 5 status LEDs

Data Storage
Storage medium internal 2 GB microSD card, direct logging to USB stick possible.
Data Export via USB 2.0 Host

Environment Dry Standards


-10...+50 (with pre-installed mains ~ +14 ˚F to +122 ˚F (with pre-installed
Operating temperature
power cable +5...+40 °C) mains power cable +41...+104 ˚F)
Storage temperature -20...+70 °C ~ -4 ˚F to +158 ˚F
Relative air humidity 0...95 % (not condensing)
Protection type IP65 NEMA 4X
Pollution level 2
Accessories

Mechanical system
Dimensions (width x
280 x 170 x 94 mm ~ 11” x 6.7” x 3.7”
height x depth)
Weight 3.7 kg ~ 8.2 lbs
Materials Housing: aluminium die-cast alloy, front panel: acrylic glass (PMMA)
Systems

D02-000en202204 TriOS Catalogue 73


COntroller // TriBox mini

TriBox mini
Photometer

20C000000
Fluorometer

Digital 2-channel controller


Digital 2-channel controller with 2 digital sensor
inputs and two 4...20 mA outputs. The digital
2-channel controller is compatible with all digital
TriOS sensors. All of the measured values and
diagnostics data that are saved can be selected
Radiometer

using an integrated web browser.

Benefits

• Open Modbus RTU communication


• For all digital TriOS sensors with Modbus communica-
tion
• Low-cost alternative to analogue measuring points
eCHEM

• Integrated data logger with service logbook


• WiFi for communication via web browser

TriBox mini NET


Controller

20C100000
Instead of WiFi, the TriBox mini NET has an Ethernet connection via the right port.
Dry Standards

Technical Specifications

Voltage supply 100...240 VAC, 50...60 Hz, 10...15 VDC


Power consumption Typ: 2 W, max.: 40 W

Connection 2 M12 industrial connectors for TriOS sensors


Standard RS-232, RS-485
Accessories

Protocol Modbus RTU, TriOS

Server RTU no
Client RTU yes (on each sensor connector)
Parameters Adjustable (default: 9600-8-N-1)
Systems

74 D02-000en202204 TriOS Catalogue


TriBox mini // Controller

Photometer
TB mini WiFi based on IEEE 802.11b/g/n
Standard
TB mini NET Ethernet based on IEEE 802.3i
TB mini Built-in WiFi antenna
Connection
TB mini NET COM2 sensor interface (right) with M12RJ45 cable
Protocol TCP/IP
Web interface yes

Fluorometer
USB no

Analog output 2 analog outputs, configurable 4...20 mA


Load max. 500 Ω
Connection terminals 1.5 mm² 16 AWG
Error indicator no

Radiometer
Measurement trigger no
12 VDC (only for TriOS accessories) 12 VDC (only for TriOS accessories),
Control voltage
terminal: max. 2.5 mm2 terminal: max. 14 AWG

Electrical specification 1 relay changeover contact (SPDT) / 250 VAC, 2 A / 30 VDC, 2 A


Connection terminals max. 2.5 mm² max. AWG 14

eCHEM
Valve Optional: external connection possible

Display 3.5 inch capacitive touch display (320x240 pixels)


LED 5 status LEDs

Storage medium Internal 2 GB microSD card


TB mini Via WiFi (compressed tar file)

Controller
Data export
TB mini NET via Ethernet (compressed tar file)

Operating temperature 0...+40 °C ~ +32 °F to +104 °F


Storage temperature -20...+70 °C ~ -4 °F to +158 °F
Relative air humidity 0...95 % (non-condensing)

Dry Standards
IP65 (the network cable has a lower NEMA 4X (the network cable has a
Protection type
protection class) lower protection class)

Dimensions (width x
150 x 139 x 80 mm ~ 5.9” x 5.5” x 3.2”
height x depth)
Weight 1.6 kg ~ 3.5 lbs
Housing: Aluminium die-cast alloy
Materials
Front panel: acrylic glass (PMMA)
Accessories
Systems

D02-000en202204 TriOS Catalogue 75


COntroller // HS100

HS100
Photometer

11C300000
Fluorometer

G2 DIN rail interface module for all TriOS G2 sensors


G2 interface with WiFi for DIN rail mounting (45 mm wide) for all digital TriOS sensors with G2 interface;
WiFi interface (on/off switchable), (RS-485) Modbus RTU and Modbus TCP/IP.
Input voltage: 24 VDC (± 10 %)
Radiometer

Benefits

• Open Modbus RTU communication


• For all digital TriOS sensors
eCHEM

• Low-cost alternative to analog measuring points


• WiFi for communication via web browser
Controller
Dry Standards
Accessories
Systems

76 D02-000en202204 TriOS Catalogue


HS100 // Controller

Technical Specifications

Photometer
Energy supply
Voltage supply 24 VDC (± 10 %)
Power consumption typical: 2.5 W
Sensor interfaces

Fluorometer
Connection 1x M12 plug for TriOS G2 sensors
Standard RS-485
Protocol Modbus RTU
Analog interfaces No
Switch input/output No
Relay outputs No

Radiometer
Compressed air cleaning No
Modbus RTU
Client RTU Yes (connected to the sensor)
Parameter Adjustable (default: 9600-8-N-1)
Modbus TCP
Server TCP Yes

eCHEM
TCP port Adjustable (default: 502)
Network/USB
Standard Ethernet, WiFi IEEE 802.11b/g/n
Connection 2 x RJ-45, external WiFi antenna (SMA)
Protocol TCP/IP, Modbus TCP
Web Interface Yes

Controller
USB No
Data storage No
Display
Display No
LED 4 x status LED
Dry Standards
Ambient
Operating temperature 0...+40 °C ~ +32 °F to +104 °F
Storage temperature -20...+70 °C ~ -4 °F to +158 °F
Relative air humidity 0...95 % (non-condensing)
Protection type IP20 NEMA 1
Mechanics
Accessories

Dimensions 45 x 99 x 119 mm ~ 1.8˝ x 3.9˝ x 4.7˝


Weight 0.25 kg ~ 0.5 lbs
Housing: polyamide (PA)
Materials
Front panel: acrylic glass (PMMA)
Systems

D02-000en202204 TriOS Catalogue 77


D02-000en202204 TriOS Catalogue
Dry Standards // Sensor

78
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Dry Standards
Sensor // Dry Standards

79
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Dry Standards // SolidCAL

SolidCAL
Photometer

20AXX000X
Fluorometer
Radiometer

Solid secondary standard for TriOS fluorometers


The SolidCAL solid secondary standard enables fast function and calibration checks of the TriOS enviroFlu-
HC fluorometer for PAH detection and the nanoFlu fluorometer for the detection of chl-a, cdom or phycocyanin.
The simple use of the standard ensures fast, accurate device verification, even on site. A standard is available
for each TriOS fluorometer – for enviroFlu HC also in different concentrations. In addition to the standard, the
SolidCAL kit includes a cleaning fluid and carrier.
eCHEM
Controller
Dry Standards
Accessories
Systems

80 D02-000en202204 TriOS Catalogue


FieldCAL // Dry Standards

FieldCAL

Photometer
20A210003

Secondary standard for RAMSES radiometers


The FieldCAL secondary standard enab-
les reliable calibration and function tests of

Fluorometer
RAMSES radiometers in the field. Thanks to
the special design, radiance (ARC), as well
as irradiance (ACC) sensors can be che-
cked. An adapter used for radiance sensors
is included in the set. Small dimensions and a
sturdy transport box make FieldCAL a useful tool
for light measurements in the field.

Radiometer
Benefits
• High stability
• Battery-powered
• Small size
• Easy to use

eCHEM
• For irradiance and radiance sensors

Technical Specifications

Wavelength range 430...730 nm

Controller
Light source White LED with spherical diffuser
Stability Type Better than 1% after 1 minute
Battery 4 AA (not rechargeable)
Operating time Type 50 hours per battery charge
Material POM, seawater-resistant plastic

Dry Standards
50 mm x 140 mm
~ 2" x 5.5"
Dimensions (ØxL) 50/60 mm x 182 mm (with ACC
~ 2/2.4" x 7.2" (with ACC Adapter)
Adapter)
Accessories
Systems

D02-000en202204 TriOS Catalogue 81


Dry Standards // DryCAL & TTurbCAL

DryCAL
Photometer

20A100008
Fluorometer
Radiometer

DryCAL enables high-precision validation of the corresponding enviroFlu sensor. Every DryCAL corresponds
precisely to a certain sensor and is calibrated to its specific properties, which significantly increases the
precision of the calibration.
The DryCAL is sold as a set with two dry calibration standards.
eCHEM

TTurbCAL
20A100007
Controller
Dry Standards
Accessories

The TTurbCAL is a solid matter standard, which provides an FNU value for reagent-free calibration of TriOS
TTurb sensors. The standard is very easy to use and makes device calibration on site much easier.
Systems

82 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue
Sensor // Dry Standards

83
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Accessories // Sensor

84
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
Accessories
Sensor // Accessories

85
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Accessories // Sensor

86
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
G2 InterfaceBox // Accessories

G2 InterfaceBox

Photometer
11CX00000

Fluorometer
Radiometer
The G2 InterfaceBox is available in variants with and without WiFi. G2 sensors from TriOS Mess- und Daten-
technik GmbH can be configured and controlled via the interface box. This is enabled by the web interface of
the G2 sensors, which can be accessed via a WiFi or LAN connection. The web interface can be accessed
with any browser.

Technical Specifications

eCHEM
Voltage supply 24 VDC (± 10 %)
Power consumption ≤ 1.5 W plus sensor (only the WiFi variant)

Connection 1 M12-plug for TriOS G2 sensors


Standard IEEE 802.3
Protocol Web interface (only with G2 sensors)

Controller
Analog interfaces no
Switch input/output no

Standard IEEE 802.3, IEEE 802.11 b/g/n (only the WiFi variant)
Connection 1 RJ-45 external WiFi antenna (SMA) (only the WiFi variant)
Protocol TCP/IP (only with G2 sensors) Dry Standards
Web interface no
USB no
Data storage no

Operating temperature 0...+40 °C ~ +32 °F to +104 °F


Storage temperature -20...+70 °C ~ -4 °F to +158 °F
Accessories

Relative air humidity 0...95 % (non-condensing)


Protection type IP20 NEMA 1

Dimensions (width x 60 x 35 x 126 mm / 60 x 35 x 162


~ 2.4˝ x 1.3˝ x 5˝ / ~ 2.4˝ x 1.3˝ x 6.4˝
height x depth) mm
Systems

D02-000en202204 TriOS Catalogue 87


Accessories // TTrig

TTrig
Photometer

12C100000
Fluorometer
Radiometer

TTrig is a measurement interval switch for the TriOS G2 sensors OPUS and NICO. Due to its low standby power
(<1 mW), it is ideally suited for operation with a battery as power supply. It is designed to minimize energy
consumption between measurements.
The TTrig features an additional connection for commissioning and controlling a wiper (W55).
Remote or self-sufficient measuring stations can thus be operated maintenance-free for several months.
An RJ-45 Ethernet interface provides access to the sensor's G2 web interface for downloading the measure-
ment data from the data logger with a notebook.
eCHEM

Technical Specifications
Power supply
Voltage supply 12...24 VDC, max. 4A
Power in standby <1mW
Controller

Sensor interfaces
Connection M12 for TriOS G2 sensors; 1x RJ-45
Standard RS-485
Protocol Modbus RTU
Analog interfaces No
Dry Standards

OTHER INTERFACES
1x M8 connector for wiper W55
Connection
Trigger output
ENVIRONMENT
Operating temperature 0...+40 °C
Storage temperature -10...+70 °C
Accessories

Relative air humidity 0...95 % (non-condensing)


Protection type IP64
Mechanical system
Dimensions (width x
140 x 80 x 60 mm
height x depth)
Weight 0.5 kg
Systems

88 D02-000en202204 TriOS Catalogue


SDI-12 Converter // Accessories

SDI-12 Converter

Photometer
11C100001

Fluorometer
The SDI-12 converter translates the Modbus protocol used by TriOS sensors into SDI-12 and thus serves as
an interface between the sensors and the SDI-12 interface of the peripherals.
The SDI-12 converter translates the Modbus protocol used by TriOS sensors into SDI-12 and thus serves as
an interface between the sensors and the SDI-12 interface of the peripherals. Due to its low standby power
(< 20 mW) it is perfectly suited for operation with a battery as power supply. Four status LEDs inform the user
continuously about the current operation mode and power supply. Both, measurements with G2 sensors and
wiper cleaning cycles can be controlled via the converter. The implemented Ethernet interface allows data

Radiometer
export and sensor configuration via the web interface.
With three manual buttons Sensor Scan, Wiper Cleaning and Service Mode can be activated. The position of
the rotary encoder determines the sensor address via which the sensor is addressed.
Technical Specifications
External power Power supply 12…24 VDC (± 10 %)
supply Connection terminal 1.5 mm² (AWG 16)

eCHEM
Power supply 10…24 VDC (± 10 %)
SDI-12
Power consumption in standby < 20 mW
Interface
Protocol SDI-12

Wiper Connection terminal 1.5 mm² (AWG 16)


Interface Standard W55 Wiper

Controller
Connection terminal 1.5 mm² (AWG 16)
Sensor
Standard RS485
Interface
Protocol Modbus RTU

Standard Ethernet
Network*
Connection RJ45
Dry Standards
Operating temperature -10…+40 °C ~ 14 ˚F to +104 °F
Storage temperature -10…+70 °C ~ 14 ˚F to 158 ˚F
Relative air humidity 0…95 % (non-condensing)
Protection type IP30 NEMA 1

LED 4x RGB Status LED


Accessories

Housing material PVC, Perspex


Dimensions (L x W x H) 120 x 80 x 45mm ~ 4.7” x 3.2” x 1.8”
Weight 250 g ~ 0.6 lbs

System compatibility SDI-12


Warranty 1 Year (EU & US: 2 Years)

* Only available if the connected sensor has an Ethernet interface.


Systems

D02-000en202204 TriOS Catalogue 89


Accessories // FlowCells

FC68 FlowCell for enviroFlu


Photometer

10A100003
Fluorometer
Radiometer

The FlowCell FC68 is used for bypass installation of the enviroFlu. The measurement medium is directed
eCHEM

through the cell, making measurement without a reagent on land possible.

FC48 FlowCell for TriOS Photometers


10A10000X
Controller
Dry Standards
Accessories

The FlowCell FC48 is used for bypass installations of the TriOS Photometer with a diameter of 48 mm.
Different path lengths are available.
Systems

90 D02-000en202204 TriOS Catalogue


FlowCells // Accessories

Ultrasonic FlowCell

Photometer
10A10001X

Fluorometer
Radiometer
FlowCell with integrated ultrasound cleaning
In addition to the conventional FlowCell, TriOS now offers an ultrasonic FlowCell, which combines the bypass

eCHEM
installation with direct cleaning.
Ultrasonic sound sprevents deposits forming on the measurement windows of the sensor. The built-in viewing
window and the illumination unit allow the state of the optical path be monitored at any time.
The FlowCell is suitable for a photometer with a 10 mm path as the FC 48/10 USC and for a photometer with
100 mm path as the FC 48/100 USC.

Controller
Technical Specifications

Voltage supply 12...24 VDC (± 10%)


Power consumption ≤ 15 W
Trigger input to initiate ultrasonic cleaning (galvanically isolated);
Control voltage: 5...24 VDC
Dry Standards
Control connection
Connection via M5 socket (a suitable M5 connection cable with open ends
is included in the delivery)
M5 socket with optional coaxial connector power adapter cable and
Power cable
matching 230 V power adapter

Max. internal pressure 1 bar, 2...4 L/min ~ 14.5 psig, 0.5 to 1gpm
Operating temperature +1...+40 °C ~ 34 ˚F to +104 ˚F
Accessories

Storage temperature -20...+70 °C ~ -4 ˚F to +158 ˚F


Protection type IP64 NEMA3

Dimensions (width x
115 x 136 x 90 mm ~ 4.5" x 5.4" x 3.5"
height x depth)
Weight 1 kg 2.2 lbs
Materials Housing: Polyoxymethylene (POM)
Systems

D02-000en202204 TriOS Catalogue 91


Accessories // FlowCells

FlowCell for eCHEM Sensors


Photometer

10A0X0000
Fluorometer
Radiometer

Modular FlowCell system with simple installation concept


The specially developed FlowCell for the eCHEM series is based on a simple, clever system. The side and
base pieces of the FlowCell can be detached easily with only one turn and new modules can be added. The
sensor-specific adapter pieces can also be replaced easily. Only the black attachment element is needed to
eCHEM

attach it to the wall. The FlowCell can then simply be placed in front and attached with a bolt.
The system is designed to be modular, which means that every extension can be ordered individually and
customized according to the application. This gives you complete freedom in the design of your application
and you can adapt the system in just a few simple steps. The eCHEM FlowCell system is compatible with the
FlowCell for turbidity.
Controller
Dry Standards
Accessories
Systems

92 D02-000en202204 TriOS Catalogue


FlowCells // Accessories

FlowCell for nanoFlu

Photometer
10A090000

Fluorometer
Radiometer
eCHEM
FlowCell for Turbidity Sensors

Controller
10A050000
A specialized FlowCell was developed for
the sensors of the turbidity series to minimise
reflections. This design maximises the precision of
the measurements. This FlowCell is compatible with
the FlowCell for eCHEM sensors and the nanoFlu
FlowCell. Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 93


Accessories // Sedimenter

Sedimenter
Photometer

02A100011
Fluorometer
Radiometer

The sedimenter is a flow-through device for use in turbid water. The sample is passed through the sedimenter
without pre-filtering. The sensor can also be installed in the sedimenter equipped with a wiper.
eCHEM

Suitable for OPUS, NICO, enviroFlu & microFlu. Version for LISA, LISA color and VIPER on request.

Technical specifications
Controller

Suitable for OPUS, NICO, enviroFlu & microFlu with and without wi-
Measuring device
per. Version for LISA, LISA color and VIPER on request.

Pressure range Unpressurised, open drain

Material PVC
Dimensions Installation plate for wall mounting: 800 mm x 495 mm
Dry Standards

Weight Sediment incl, wall plate only: 14.7 kg


Accessories
Systems

94 D02-000en202204 TriOS Catalogue


Wiper V2 // Accessories

Wiper W55 V2

Photometer
02A100008 • 02A100X18

Fluorometer
Radiometer
The TriOS Wiper W55 V2 provides an additional cleaning option for all TriOS photometers with path lengths
from 1 mm up to 10 mm. The wiper housing can be mounted on the sensor in just a few steps and provides
reliable cleaning of the measurement windows. The new magnetic axis lock allows quick and easy wiper
blade replacement, without any tools.
The new version of the wiper now features blockage detection and removal, and a service mode that increas-
es the life of the wiper through regular use. The accessory can also be used in seawater up to a depth of 10m.

eCHEM
Technical Specifications

Path lengths 1 mm, 2 mm, 5 mm, 10 mm

4-pin M8-plug
Control port A suitable M8 connection cable with open end is included in the scope of
delivery.
Trigger input 5 ‒ 24 VDC (±10% )

Controller
Power consumption
2...15 mA
trigger input
Operating time (max.) 3 Seconds

Dimensions L x ø 175 mm x 80 mm
Weight 0.52 kg
Dry Standards
Material NBR, POM, TPE (PP, EPDM), Titanium, V4A

Power supply 12 ‒ 24 VDC (± 10 %)


Power consumption approx. 2 ‒ 6 W in operation; max. 0.75 W in standby
Maintenance effort ≤ 0.5 h/month typical
Maintenance interval depending on application
Warranty 1 year (EU & USA : 2 years)
Accessories

Max. Pressure 1 bar


Protection Type IP68
Inflow velocity up to 10 m/s
Operating temperature +2...+40 °C
Storage temperature -10 °C...+70 °C
Systems

D02-000en202204 TriOS Catalogue 95


Accessories // AirShot2

AirShot2
Photometer

02A100010
Fluorometer

The compact pressured air cleaning system AirShot2 works with pressured air pulses instead of a continuous
air flow, thus reducing the required amount of air significantly and enabling a very compact design.
Furthermore the pressure pulses perform a more effective cleaning than continuous air flow systems, making
Radiometer

the AirShot2 a valuable addition to every system.


AirShot2 can be used as an alternative to a standard compressor and can be operated with a TriBox3.
The cleaning process of the AirShot2 requires only 10 seconds. It can be triggered at a minimum interval of
5 minutes.

Technical specifications
Energy supply
eCHEM

230 V Ver­
230 VAC, max. 200 W, 0.86 A
Voltage sion
supply 110 V Ver­
110 VAC, max. 200 W, 1.8 A
sion
Interfaces
Connection for 6 mm hoses ( 4 mm inner diameter )
Controller

Power cable length 3m


Control line length 5m
Trigger Input 12...24 VDC, M8 4-Pin
Wiper Output M8 4-Pin
Display
Dry Standards

LED 3 x Status LED


Ambient
Temperature Impulse Box -5...+40 °C
Temperature Compressor -10...+40 °C
Protection type IP44
Mechanics
Accessories

Size w/h/d 190 x 260 x 125 mm and 90 x Ø46 mm


Weight 4.4 kg
Housing Polycarbonate
Settings
Standard 10 s every 5 min
Max. Pressure 7 bar
Systems

96 D02-000en202204 TriOS Catalogue


Solenoid Valve V2 // Accessories

Solenoid Valve V2 for TriBox mini

Photometer
03A000003

Fluorometer
The TriBox mini supports operation of an external, controllable valve for the purposes of water or compres-

Radiometer
sed-air cleaning. All Solenoid Valve V2 settings can be configured via the TriBox mini menu ("Measurement
& Cleaning", sub-item "Cleaning").
The Solenoid Valve V2 can be installed very easily. It has four 5.3 mm holes for installation.

Available configurations:
• Interval cleaning

eCHEM
• Duration of cleaning
• Pause before measurement

Compressor

Controller
Sensor
Connection to TriBox mini

Technical Specifications Dry Standards

Dimensions 110 x 97 x 55 mm ~ 4.3" x 3.8" x 2.2"


Weight ~ 0.6 kg ~ 1.3 lbs
Max. pressure 5 bar ~ 72.5 psig
Voltage supply 12 VDC
Power consumption 3W
Accessories

for 6 mm hoses (4 mm inner diame- for ~0.23" hoses (~0.16" inner diame-
Connection
ter) ter)
Housing Die-cast aluminium alloy
Protection type IP65 NEMA 4X
Cables 1.5 m connector cable with M8 plug ~ 4.9 ft connector cable with M8 plug
Temperature 2...+40 °C ~ 35.6 ˚F to +104 ˚F
Systems

D02-000en202204 TriOS Catalogue 97


Accessories // MIB

Modbus Interface Board


Photometer

07A000000
Fluorometer
Radiometer

The Modbus interface controls the sensor interfaces of the TriBox3, TriBox Mini or the TriOS G2 sensors
with connectors, providing simple, flexible connection options. The TriBox is connected via a standard M12
extension cable. TriOS G2 sensors with M12 connectors can be connected directly. To operate the sensors, a
power supply must be connected to the interface, which is connected directly to the sensor. Additional moun-
ting holes in the aluminium L profile make installation easy.
eCHEM

Technical Specifications
12…24 VDC (+/- 10%), only required for operation with sensors
Voltage supply
2 pin PCB plug connector

G2 sensor connector 1 M12 built-in socket


G2 sensor serial tap 4 pin PCB plug connector
Controller

G2 sensor network tap 1 RJ-45 socket, standard: IEEE 802.3i (10BaseT)


TriBox connection 1 M12 built-in plug, connection via standard M12 extension
TriBox serial tap 4 pin PCB plug connector

Operating temperature 0...+40 °C ~ +32 °F to +104 °F


Dry Standards

Storage temperature -20...+70 °C ~ -4 °F to +158 °F


Relative air humidity 0...95 % (non-condensing)
Protection type IP10 NEMA 1

Dimensions (width x
110 x 40 x 95 mm ~ 4.3˝ x 1.6˝ x 3.7˝
height x depth)
Weight 180 g ~ 0.4 lbs
Accessories

Material Aluminium
Systems

98 D02-000en202204 TriOS Catalogue


TAMMO // Accessories

TAMMO

Photometer
07A000001

Fluorometer
TAMMO is an expansion module for TriBox3, which converts analog signals to RS-485 Modbus RTU protocol.
The analog to Modbus module provides a total of two current inputs, where both the parameter and the unit
for two parameters can be set.

Radiometer
The TriBox3 must have at least software version V1.5.4 installed. For older versions, a soft­
ware upgrade must be performed first.

Technical Specifications
Power supply
Power supply 12 V / 24 V (done by TriBox3)

eCHEM
Power consumption < 100 mW
Sensor interfaces
Connection terminal 1.5 qmm (AWG 16)
Standard RS-485
Protocol Modbus RTU

Controller
ANALOG INTERFACES
2x current input:
Analog input 4-20 mA (default setting in TriBox3)
0-20 mA (configurable at TriBox3)
Measurement accuracy ± 0,2 % of Full Scale Range

Dry Standards
Measurement rate ~ 60 SPS
Connection terminal 1.5 qmm (AWG 16)
AMbient
Operating temperature -10...+50 °C
Storage temperature -20...+70 °C
Relative air humidity 0...95 % (non-condensing)
Protection type IP00
Accessories

Mechanics
Dimensions L/W/H 59x32x28 mm
Weight 14 g

System compatibility TriBox3, as of software V1.5.4


Warranty 1 year (EU & USA: 2 years)
Systems

D02-000en202204 TriOS Catalogue 99


Accessories // Float

Float
Photometer

05A000005
Fluorometer
Radiometer

The TriOS float is the ideal solution for use in fluctuating water levels. The float comes with two sizes of
sensor brackets so that both the TriOS photometer with its 48 mm diameter and the enviroFlu with its 68 mm
eCHEM

diameter can be attached. One sensor at a time can be attached to the float.
TriOS also offers sensor brackets for small sensors, such as the nanoFlu (05A000006). With this, several
sensors can be attached to one float.
The float stays on the surface of the water with the sensor always in the medium. The float can easily be
removed from the medium by its handle to do a check or clean it. Side attachments of stainless steel cables
prevent the float from being carried away.
Controller
Dry Standards
Accessories
Systems

100 D02-000en202204 TriOS Catalogue


Pipe Adapter // Accessories

Pipe Adapter

Photometer
06A0000XX

For installation in existing pipe systems, such as pool edge fixtures, TriOS offers adapter pieces with G1 or
NPT1 thread for the following sensors:

Fluorometer
• TpH
• TpH-D
• TTurb
• Conductivity
• Oxygen

Radiometer
eCHEM
Controller
Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 101


Accessories // Telescopic Rod

Telescopic Rod
Photometer

12A000000
Fluorometer
Radiometer

The new TriOS telescopic rod provides a solid and reliable mounting method for the TriOS dissolved oxygen
eCHEM

sensor. The sensor is permanently mounted in the head section of the telescopic rod and can be immersed in
the medium by extending the telescopic tubes to a distance of 6.8m. The rod can be held by hand or attached
to a railing or similar with the supplied double clamp. Due to the material mix of carbon and fiberglass, the rod
is grippy and light at the same time.
Controller

Technical specifications

Dimensions LxW 6800 mm x 90 mm


Weight 2.32 kg
Dry Standards

Material Telescopic rod: carbon fiberglass mix, bracket: aluminum


Accessories
Systems

102 D02-000en202204 TriOS Catalogue


Frames & Clamps // Accessories

RAMSES Frames

Photometer
05A000000

Fluorometer
Radiometer
05A000002

eCHEM
Controller
Hydraulic Clamps CL48 & CL68 Dry Standards
01A100000X
Accessories
Systems

D02-000en202204 TriOS Catalogue 103


Accessories // Water Quality Panel

Water Qualitäty Panel


Photometer

11A10000X

The modern TriOS bypass panel makes it possible to cleanly and precisely monitor water quality on site. The
Fluorometer

sensor is passed through the FlowCells and thus analysed for various parameters. The panel can be ordered
in different designs and sensor assemblies.
Radiometer
eCHEM
Controller
Dry Standards

11A100002 Water quality panel with pH, conductivity, turbidity, chlorine, TriBox mini
Accessories

11A100003 Water quality panel with pH, conductivity, turbidity, chlorine, TriBox 3
11A100004 Water quality panel with pH, conductivity, turbidity, TriBox mini
Systems

104 D02-000en202204 TriOS Catalogue


pH Buffer Set // Accessories

pH Buffer Set

Photometer
80P000002

Fluorometer
Radiometer
pH Buffer Solution
TriOS provides the necessary certified buffer solution with pH4 and pH 7 to calibrate TriOS TpH-D sensors.
No transfer of fluids necessary, as the containers fit directly into the calibration process.

Quick and easy calibration of all EGC Quality Analyzer sensors directly at the site. No dangerous fluids, no

eCHEM
expertise needed! Let the wizard of the TriBox guide you through every step of the process.

Controller
Dry Standards
Accessories
Systems

D02-000en202204 TriOS Catalogue 105


Accessories //

Panels
Photometer

11A10000X
Fluorometer
Radiometer

Flange DN50 / DN80 / DN100


Flange solution for pipeline installation, according to DIN11851.
eCHEM
Controller

Compressed Air Cleaning Head for enviroFlu


Dry Standards

02A100003
Accessories
Systems

106 D02-000en202204 TriOS Catalogue


// Accessories

Protective cage for enviroFlu or W55 wiper

Photometer
00P100005 . 00P100010

Fluorometer
Radiometer
Cuvette holder
for 5 mm quartz glass cuvette with 10 mm path*
10A200000

eCHEM
Controller
*For all photometers: OPUS, LISA, LISA color, VIPER, NICO

VALtub for photometer validation* Dry Standards


10A30000X
Accessories

*For all photometers: OPUS, LISA, LISA color, VIPER, NICO


Systems

D02-000en202204 TriOS Catalogue 107


Accessories // Sensor

Optics Cleaning Set


Photometer

05A000004
Fluorometer
Radiometer

Cable
50A0XXXX0
eCHEM
Controller

5-input M12 Sensor Connector Box


Dry Standards

50A000001
Accessories
Systems

108 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue
Sensor // Accessories

109
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
D02-000en202204 TriOS Catalogue
Systems // Sensor

110
Photometer Fluorometer Radiometer eCHEM Controller Dry Standards Accessories Systems
D02-000en202204 TriOS Catalogue
SystemS
Sensor // Systems

111
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Systems // EGC Water Analyzer

EGC Water Analyzer


Photometer

11A10001X
Fluorometer
Radiometer
eCHEM

The EGC Water Analyzer is TriOS‘ latest development in the monitoring of various wastewater-parameters.
It can be equipped with three sensors: enviroFlu for identification of polycyclic aromatic hydrocarbons (PAH),
TTurb for turbidity measurements and TpH-D for the determination of the pH value.
Inside the measurement cabinet is a TriBox3 to which all sensors are connected. The Ethernet interface and
the analogue outputs are directly connected to the transparent connector box.
Controller

Certified by DNV and ABS!


Dry Standards
Accessories

Equipped with the enviroFlu, TTurb and TpH-D in the appropriate configuration, a TriBox3 (from software
version 1.4.22) and wire rope dampers, the analyzer has a ship approval according to IMO regulations
MEPC.259(68).
Systems

112 D02-000en202204 TriOS Catalogue


EGC Water Analyzer // Systems

Technical Specifications

Photometer
Power supply
Voltage supply 100 … 240 VAC, 50 … 60 Hz
Power consumption Max. 50 W
Interfaces

Fluorometer
digital Ethernet
analogue 6 outputs: 4…20 mA
Load max. 500 Ω
Protocol Modbus TCP/IP
PAH (MEPC.259(68))
pH (BS EN 60746-2:2003)

Radiometer
Turbidity (DIN EN ISO 7027:2016)
Parameters
Temperature (of TpH-D)
Flow (internal)
PAH turbidity corrected
Mechanical system
Size (width x height x
600 x 800 x 337 mm ~ 23.6“ x 31.5“ x 13.3“
depth)

eCHEM
43 kg (without sensors) ~ 95 lbs (without sensors)
Weight
45.5 kg (with sensors) ~ 100 lbs (with sensors)
Environment
Sample temperature +2°C…+40°C ~ +36 °F to +104 °F
Ambient temperature 0°C…+45°C ~ +32 °F to +113 °F
Storage temperature -20°C…+80°C ~ -4 °F to +176 °F

Controller
Relative air humidity 0...95% (non-condensing)
pH value > pH4
Protection type IP56 NEMA 4
Inlet
Inlet pres-
Max. pres­ 1 to 25 bar maximum ~ 14.5 psig to 363 psig maximum
Dry Standards
sure
sure
Internal max. 3 bar ~ 43.5 psig
Flow volume 2...5 L/min
Internal volume Approx. 1 L
Accessories
Systems

D02-000en202204 TriOS Catalogue 113


Systems // MEAS100

MEAS100
Photometer

11A100007
Fluorometer
Radiometer
eCHEM
Controller

Automatic sampling with the Monitoring Event Automatic Sampler


The new TriOS sample collection system is a stationary sampler with integrated measurement technology
in a stainless steel housing. It uses thermostatic control for automatic sample extraction according to the
vacuum principle. Up to 12 sample containers can be used.
Dry Standards

Technical Specifications

Double-walled stainless steel (material 1.4301) with 40 mm insulation.


Housing separated into sample compartment and control compart-
Accessories

Housing ment, each with lockable door. Upper door with Plexiglas window.
Protective cover made of Styrosun that can be propped open for
connection and maintenance work
Independent, regulated cooling / heating with four settings, no-frost
Sample compartment temperature:
Thermostatic control
~ +39.2 °F (adjustable from
4 °C (adjustable from 0...9.9 °C)
32...49.8 °F)
Systems

114 D02-000en202204 TriOS Catalogue


MEAS100 // Systems

Photometer
Sampling modes Time-dependent, volume-dependent, event controlled, manual
Microprocessor control, sleep mode (<5 mA), 8-16 V power supply, foil
Control keypad, with key field (0-9, ESC, ENT, cursor keys)
graphical display (128x64 pixels), background illumination
3000 entries, non-volatile data memory;
Data storage sampling and malfunction report data, including sample extractions, bottle
changes, reports, external signals

Fluorometer
Programming Twelve (12) freely programmable application programs with program links
• Immediately
• Date / time
Program start options
• Day of week / time
• With external signal
• After 1 run
Programme end / stop
options • After X runs

Radiometer
• Continuous operation
• Date/time
Pause mode Interruption of program run at any time
Overfilling protection Adjustable from 1–999 samples / bottles
Intervals setting 1 min. to 99 h 59 min in steps of 1 minute
Pulse setting 1 to 9999 pulses/sample
Manual sample extraction Possible at any time without interrupting the current program run

eCHEM
Program protection Up to 5 years after loss of power supply

Interface Mini-USB, RS-232


• 2 analog: 0/4...20 mA
• 8 digital (volume, event, 1 freely programmable)
Signal inputs • Pulse length at least 60 ms; switch level 7...24 V
• Max. working resistance: 500 Ohm; max. length of signal cable: 30 m /

Controller
98.4 ft
Signal output / status
8 digital; 1 of them being the collective malfunction message
messages
Vacuum system 1000 ml
Metering system
U system, suction height up to 40 m / 131.2 ft
Single sample volume
Vacuum system: < 2.5 % or +/- 3 ml
accuracy Dry Standards
Dimensions (height x 1490 (2040 with open cover) x 605 x ~ 58.7" (80.3" with open cover) x
width x depth) 645 mm 23.8" x 25.4"
Weight ~ 110 kg with composite container ~ 242.5 lbs with composite container
Materials with medium
PC, PVC, silicone, PS, PE, EPDM
contact
Auxiliary power / Power
230 V / 115 V /AC
Accessories

supply
Power consumption approx. 350 VA (with cooling)
Ambient -20...+43 °C ~ -4 °F to +109.4 °F
Sample temperature 0...+40 °C ~ +32 °F to +104 °F
Standards CE; sampling according to ISO 5667-10, EN16479
Systems

D02-000en202204 TriOS Catalogue 115


Systems // Wall-Mounted Sampler

Online measurement with integrated


Photometer

wall-mounted sampler
For use in hard-to-reach measuring points, for
example, TriOS has taken the proven stationary
Fluorometer

sampler with pressure-vacuum technology and


combined it with optical, reagent-free sensors.
A clear display and numeric keypad allow program-
ming in a very short time. The sampler offers time-
and quantity-based sampling and is extremely low
maintenance due to its simple design. It is weather-
proof and can be mounted or fixed to a wall.
Radiometer

The pressure vacuum sampler operates according


to ISO 5667 and thus meets the requirements for
subsequent reproducible analysis with the integra-
ted online sensor or analysis in the laboratory.
eCHEM
Controller
Dry Standards
Accessories
Systems

116 D02-000en202204 TriOS Catalogue


D02-000en202204 TriOS Catalogue
Sensor // Systems

117
Systems Accessories Dry Standards Controller eCHEM Radiometer Fluorometer Photometer
Annex

118 D02-000en202204 TriOS Catalogue


Annex

Annex
D02-000en202204 TriOS Catalogue 119
Opus UV: measurement ranges depending on the path length*
120

Annex
Parameters Measurement principle Unit Factor Path length (mm)
0.3 1 2 5 10 20 50

Absorbance (AU) Spectral AU** - 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2 0.01...2.2
Absorbance (1/m) Spectral 1/m - 50...7300 15...2200 7.5...1100 3...440 1.5...220 0.75...110 0.3...44
Nitrate N-NO3 Spectral mg/L - 1.0...330 0.3...100 0.15...50 0.06...20 0.03...10 0.015...5 0.006...2
Nitrate NO3 Spectral mg/L - 4.43...1460 1.33...440 0.67...220 0.27...88 0.13...44 0.067...22 0.030...9
Nitrite N-NO2 Spectral mg/L - 1.7...500 0.5...150 0.25...75 0.1...30 0.05...15 0.025...7.5 0.01...3
Nitrite NO2 Spectral mg/L - 5.6...1650 1.65...500 0.82...250 0.33...100 0.17...50 0.083...25 0.033...10
DOCeq Spectral mg/L - 17...3300 5.0...1000 2.5...500 1.0...200 0.5...100 0.25...50 0.1...20
TOCeq Spectral mg/L - 17...3300 5.0...1000 2.5...500 1.0...200 0.5...100 0.25...50 0.1...20
CODeq Spectral mg/L - 100...7300*** 30...2200*** 15...1100*** 6.0...440*** 3.0...220*** 1.5...110*** 0.6...44***
BODeq Spectral mg/L - 100...7300*** 30...2200*** 15...1100*** 6.0...440*** 3.0...220*** 1.5...110*** 0.6...44***
KHP Spectral mg/L - 17...13300 5.0...4000 2.5...2000 1.0...800 0.5...400 0.25...200 0.1...80
SAC254 Single wavelengths 1/m - 50...7300 15...2200 7.5...1100 3.0...440 1.5...220 0.75...110 0.3...44
COD-SACeq**** Single wavelengths mg/L 1.46 75...10600 22...3200 11...1600 4.4...640 2.2...320 1.1...160 0.44...64
BOD-SACeq***** Single wavelengths mg/L 0.48 24...3500 7.2...1050 3.6...525 1.44...210 0.72...105 0.36...52.5 0.15...21
TSSeq***** Single wavelength mg/L 2.6 130...4300 40...1300 20...650 8.0...260 4...130 2.0...65 0.8...26
D02-000en202204 TriOS Catalogue

* under laboratory conditions


** unit of absorption level
*** depends on the composition of the COD or BOD (sum parameters)
**** based on KHP (note: 100 mg COD standard solution is equivalent to 85 mg/L KHP)
***** based on SiO2

Note:
1 mg/L N-NO3 is equivalent to 4.43 mg/L NO3
1 mg/L N-NO2 is equivalent to 3.28 mg/L NO2
VIPER: measurement ranges depending on the path length*
D02-000en202204 TriOS Catalogue

Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
10 50 100 150 250

SAC436 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
SAC525 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
SAC620 DIN EN ISO 7887: 2012-04 1/m - 1...250 0.2...50 0.1...25 0.06...17 0.04...10
True colour 410 DIN EN ISO 7887: 2012-04 mg/L Pt 18.52 20...3750 4...750 2...375 1.2...250 0.8...150
Pt-Co color 390 DIN EN ISO 6271:2016-05 mg/L Pt 7.4 8...1500 1.6...300 0.8...150 0.4...100 0.2...60
Pt-Co-Color 455 DIN EN ISO 6271:2016-05 mg/L Pt 36.4 40...7500 8...1500 4...750 2.4...500 1.4...300
Cr-Co color 380 - ° (degree of colour) 9.7 10.0...2000 2...400 1...200 0.6...130 0.4...80
Cr-Co colour 413 Gost 3351-74 ° (degree of colour) 34.1 40...7000 8...1400 4...700 2.6...450 1.6...275

Annex
121

* under laboratory conditions


LISA UV: measurement ranges depending on the path length*
122

Annex
Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
1 2 5 10 50

SAC254 DIN 38404-3: 2005-07 C3 1/m - 5...1500 2.5...750 1...300 0.5...150 0.1...30
CODeq** - mg/L 1.46 8...2200 4...1100 1.5...440 0.8...220 0.15...45
BODeq** - mg/L 0.48 2.5...700 1.25...350 0.5...140 0.25...70 0.05...15
TOCeq** - mg/L 0.584 3...880 1.5...440 0.6...175 0.3...90 0.06...20
Turbidity 530 nm - FAU*** 3.2054 / 0.0096 20...4000 10...1400 4...420 2...200 0.4...40
D02-000en202204 TriOS Catalogue

* under laboratory conditions


** based on KHP (Note: 100 mg COD standard solution is equivalent to 85 mg/L KHP)
***Formazine attenuation unit
LISA color: measurement ranges depending on the path length*
D02-000en202204 TriOS Catalogue

Path length Path length Path length Path length Path length
Parameters according to Unit Factor
(mm) (mm) (mm) (mm) (mm)
10 50 100 150 250

SAC436 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
SAC525 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
SAC620 DIN EN ISO 7887: 2012-04 1/m - 0.5...150 0.1...30 0.05...15 0.03...10 0.02...6
True color 410 DIN EN ISO 7887: 2012-04 mg/L Pt 18.52 10.0...2800 2...560 1.0...280 0.6...185 0.4...110
Pt-Co color 390 DIN EN ISO 6271:2016-05 mg/L Pt 7.4 4.0...1100 0.8...220 0.4...110 0.3...75 0.2...45
Pt-Co-Color 455 DIN EN ISO 6271:2016-05 mg/L Pt 36.4 20...5500 4.0...1100 2.0...550 1.5...360 0.8...220
Cr-Co color 380 - ° (degree of colour) 9.7 5.0...1500 1.0...300 0.5...150 0.3...100 0.2...60
Cr-Co color 413 Gost 3351-74 ° (degree of colour) 34.1 20...5500 4.0...1100 2.0...550 1.5...360 0.8...220

Annex
* under laboratory conditions
123

**Formazine attenuation unit


NICO: Measurement ranges depending on the path length*
124

Annex
Path length Path length Path length Path length Path length Path length Path length
Parameters Unit Factor
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
0,3 1 2 5 10 20 50

Nitrate NO3-N [mg/L] - 0…200 0…60 0…30 0…12 0…6 0…3 0…1.2
Nitrate NO3 [mg/L] - 0…886 0…266 0…133 0…53 0…26.6 0…13 0…5
D02-000en202204 TriOS Catalogue

* under laboratory conditions


Cr-Co color scale2
Pt-Co color scale1

PAH (oil in water)

Chlorine Dioxide
Cyanobacteria
Chlorophyll a
Nitrate NO3-N

Free Chlorine
Nitrite NO2-N

COD-SACeq
BOD-SACeq

Temperature
TOC-SACeq

Conductivity
Solid matter
Fluorescein
Rhodamine

Tryptophan

Irradiance
Radiance
Coloring3

pH value
Turbidity

Oxygen
CODeq

DOCeq
BODeq

TOCeq
TSSeq

SAC254
SAC436

cdom
BTX4
KHP
D02-000en202204 TriOS Catalogue

[mg/L] [µg/L] FNU g/L pH µS [mg/L] °C

OPUS
OPUS aero
NICO
Absorption NICO plus
LISA UV
LISA color5
VIPER
enviroFlu5
matrixFlu VIS
Fluorescence nanoFlu5
microFlu HC
microFlu V2
Radiometry RAMSES
TTurb
TpH
TpH-D
Conductivity
eCHEM Conductivity inductive
Dissolved Oxygen
Free Chlorine
Chlorine Dioxide

Annex
Total Chlorine
1
390 nm, 455 nm (Apha/Hazen)
2
380 nm, 413 nm
3
410 nm, 436 nm, 525 nm, 620 nm
4
mono-aromatic hydrocarbons
125

5
depending on version
Annex

SDI-12 Converter
compatible
TriOS Protocol Modbus able
(Device Driver availa-
ble)

OPUS

OPUS aero

NICO
Absorption NICO plus

LISA UV

LISA color5

VIPER

enviroFlu

enviroFlu HC MB

matrixFlu VIS
Fluorescence
nanoFlu

microFlu HC

microFlu V2

RAMSES
Radiometry
RAMSES G2

Turbidity TTurb

TpH

TpH-D

Conductivity

Conductivity Induktive
eCHEM
Dissolved Oxygen

Free Chlorine

Chlorine Dioxide

Total Chlorine

126 D02-000en202204 TriOS Catalogue