0% found this document useful (0 votes)
77 views4 pages

1SDA067412R1 xt1n 160 TMD 40 450 3p F F

The document provides product details for an XT1N 160 TMD 40-450 3p F F circuit breaker. It includes general information, ordering details, dimensions, environmental information, standards, and certifications. The circuit breaker has a rated current of 40 A, rated voltage of 690 V, and rated short-circuit breaking capacity of 50 kA. It is a three-pole molded case circuit breaker with fixed terminals and thermomagnetic release.

Uploaded by

muneeb abdul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views4 pages

1SDA067412R1 xt1n 160 TMD 40 450 3p F F

The document provides product details for an XT1N 160 TMD 40-450 3p F F circuit breaker. It includes general information, ordering details, dimensions, environmental information, standards, and certifications. The circuit breaker has a rated current of 40 A, rated voltage of 690 V, and rated short-circuit breaking capacity of 50 kA. It is a three-pole molded case circuit breaker with fixed terminals and thermomagnetic release.

Uploaded by

muneeb abdul
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

PRODUCT-DETAILS

XT1N 160 TMD 40-450 3p F F


XT1N 160 TMD 40-450 3p F F

General Information
Extended Product Type XT1N 160 TMD 40-450 3p F F
Product ID 1SDA067412R1
EAN 8015644013066
Catalog Description XT1N 160 TMD 40-450 3p F F
C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND
Long Description
THERMOMAGNETIC RELEASE TMD R 40-450 A

Ordering
Order Code US and XT1NE3040AFF000XXX
Canada
E-Number (Finland) 3640523
EAN 8015644013066
Minimum Order Quantity 1 piece
Customs Tariff Number 85362090

Dimensions
Product Net Width 76.2 mm
Product Net Height 130 mm
Product Net Depth / 70 mm
Length
Product Net Weight 1.08 kg
XT1N 160 TMD 40-450 3p F F 2

Container Information
Package Level 1 Units box 1 piece
Package Level 1 Width 128 mm
Package Level 1 Height 135 mm
Package Level 1 Depth / 143 mm
Length
Package Level 1 Gross 1.137 kg
Weight
Package Level 1 EAN 8015644013066

Environmental
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Additional Information
Circuit Breaker Type to Power Distribution
be Associated
Current Type AC/DC
Electrical Durability 120 cycles per hour
8000 cycle
Mechanical Durability 240 cycles per hour
25000 cycle
Number of Poles 3
Opening Time CB with SOR 15 ms
CB with UVR 15 ms
Order Multiple 1 piece
Power Loss at Rated Operating Conditions per Pole 2.6 W
Product Main Type SACE Tmax XT
Product Name Moulded Case Circuit Breaker
Product Type CB
Rated Current (I n ) 40 A
Rated Frequency (f) 50 / 60 Hz
Rated Voltage (U r ) 690 V
Rated Impulse 8 kV
Withstand Voltage (U imp
)
Rated Instantaneous 450 A
Short-Circuit Current
Setting (I i )
Rated Insulation Voltage 800 V
(U i )
Rated Operational 690 V AC
Voltage 500 V DC
Rated Service Short- (220 V AC) 50 kA
Circuit Breaking (230 V AC) 50 kA
Capacity (I cs ) (240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short- (220 V AC) 65 kA
Circuit Breaking (230 V AC) 65 kA
Capacity (I cu ) (240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
XT1N 160 TMD 40-450 3p F F 3

(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted 160 A
Current (I u )
Release TMD
Release Type TM
Setting Range 28...40 A
Short-Circuit N
Performance Level
Standards IEC
Sub-type XT1
Terminal Connection Fixed Circuit-Breakers
Type
Version F
CAD Dimensional 1SDH001295R0008
Drawing

Certificates and Declarations (Document Number)


Data Sheet, Technical 1SDC210100D0206
Information 1SDC210099D0206
Declaration of 9AKK106713A5532
Conformity - CE
Environmental 9AKK107991A8215
Information
GL Certificate 1SDL000163R0103
Instructions and 1SDH000719R0001
Manuals
LR Certificate 1SDL000163R0100
REACH Declaration 9AKK108466A1425
RoHS Information 9AKK108466A1424
Mechanical Drawings 1SDH000719R0100
Wiring Diagram 1SDM000068R0001

Classifications
ETIM 4 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 5 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 6 EC000228 - Power circuit-breaker for trafo/generator/installation prot.
ETIM 7 EC000228 - Power circuit-breaker for trafo/generator/installation
protection
ETIM 8 EC000228 - Power circuit-breaker for trafo/generator/installation
protection
Object Classification Q
Code
UNSPSC 39120000
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
eClass V11.1 : 27370409

Categories
XT1N 160 TMD 40-450 3p F F 4

Low Voltage Products and Systems  → Circuit Breakers  → Moulded Case Circuit Breakers  → Tmax XT

You might also like