The DS7240V2 control panel has eight onboard zones that can expand to 40 zones, four outputs that can expand to 20, and supports up to four areas. It is suitable for commercial burglary and residential fire/burglary systems. The control panel has eight users with an option for key fob operation, four authority levels, and stores 254 events in its log. It can communicate with two destinations and be remotely programmed. An optional door access control module is also available.

Uploaded by

Forward Myanmar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views

DS7240V2 Control Panel

The DS7240V2 control panel has eight onboard zones that can expand to 40 zones, four outputs that can expand to 20, and supports up to four areas. It is suitable for commercial burglary and residential fire/burglary systems. The control panel has eight users with an option for key fob operation, four authority levels, and stores 254 events in its log. It can communicate with two destinations and be remotely programmed. An optional door access control module is also available.

Uploaded by

Forward Myanmar
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Intrusion Systems | DS7240V2 Control Panel

DS7240V2 Control Panel


▶ Eight on-board zones
▶ Eight programmable Skeds
▶ RF compatibility
▶ Up to 32 users with optional key fob operation
available
▶ Four programmable authority levels
▶ Two communications routing destinations
▶ 254 event log
▶ Remote-programmable with RPS
▶ Optional Door Access Control Module (DACM)
▶ Network communication option (LAN/WAN)

The DS7240V2 Control Panel has eight zones expandable System Overview
to 40, four outputs expandable to 20, and four areas. It is
suitable for commercial burglary and residential fire/
burglary applications. 1 2 3

4 5 6

7 8 9
18 V AC

AUXILIAR Y
GRN YEL
Data
Aux Power
- -

R
ST ATUS
INST ALLER
12 VDC
+

R1
+

T1

PO1 SELECT
Aux/Data

T
R Y G B

BA TT+

BA TT - ALRM PO1 SMK


PO4

PO2
PO3

+ A B + L-1 COM L-2 L-3 COM L-4 L-5 COM L-6 L-7 COM L-8

ON

1 2 3 4 5 6

+OUT - TMPR R B G Y 1 COM 2 3 COM 4 5 COM 6 7 COM 8


10
4
3
2
1
N
O

8 7 6 5 4 3 2 1 O NO
N

F FO

8 7 6 5 4 3 2 1

11
LED
ENABLE
Rx Tx Tx Rx
BUS SER
P2

P6
R
Y
G

14
B

P1

DB9 GND
ENABLE
P3

12
LED
ENABLE
Rx Tx Tx Rx
BUS SER
P2

P6
R
Y
G
B

P1

DB9 GND
ENABLE
P3

15 13

www.boschsecurity.com
2 | DS7240V2 Control Panel

1. DS7445i LED Keypad Remote Programming Software (RPS) is a Windows®-


2. DS7445V2 LED Keypad based account management and panel programming and
3. Door Access Control Module (DACM) diagnostic utility. It is designed to remotely (or locally
using the DX4010i Aux Data pins) set up and program the
4. DS7447E LCD Keypad
DS7240V2 Control Panels.
5. DS7447V2 LCD Keypad
LED and LCD Keypad Support
6. RF3227E RF Receiver
7. DS7220V2 Control Panel Keypad Description
8. DX3010 Octo-output Expander DS7445i LED Keypad Provide 16 operating LEDs, and eight sys-
9. DX2010 Input Expander DS7445V2 LED Keypad tem status LEDs that indicate conditions
such as armed, fire alarm, and trouble.
10. DX3020 X-10 Interface Module
DS7446KP LCD Keypad Two-line displays allow custom zone and
11. DX4020 Network Interface Module DS7447E LCD Keypad area descriptions up to 16 characters. The
12. DX4010i RS-232 Serial Interface Module DS7447V2 LCD Keypad end user can adjust the sounder volume
13. DX4010i RS-232 Serial Interface Module and backlight intensity using easy button
commands.
14. DS7447E LCD Keypad
15. DS7447V2 LCD Keypad LED and LCD keypads can be used in the same DS7240V2
Control Panel system.
PK32
Functions The DS7240V2 Control Panel has an optional PK32
Programming Key that can copy one control panel's
Alarm Verification Option
programming to another control panel. This can be used
Central station personnel are able to verify alarms with a
as an installer’s template. The installer could store a
two-way voice session with the premises and/or visually
residential template in one PK32 and a commercial
through an on-premises camera connected to the optional
template in another PK32. The on-board LED illuminates
rvm4c Remote Video Module.
when information is sent to or from the key, and blinks
Eight On-board Zones when functional diagnostics are performed on the key.
The DS7240V2 Control Panel has eight on-board zones. It
Flexible Digital Communications
can have hard-wired expanded zones and wireless zones.
The DS7240V2 Control Panel works with most alarm
Program any of these zones to follow one of 15 zone
receivers that support Contact ID and SIA 300 digital
functions.
communicator formats and pager format. The pager
The DS7240V2 Control Panel also allows configuration format allows control panels to dial a digital pager service
using two resistors for each sensor loop. The control and leave a numeric message representing the account
panel monitors two zones for each sensor loop, making 16 number, event number, area number, and zone or user
on-board zones available. Zone doubling is also available number.
on hard-wired expanded zones.
Network Communication Option
When programming zones for entry or exit delay times, Adding a DX4020 Network Interface Module provides bi-
you can choose a longer delay time for zones located a directional communications over an Ethernet network.
longer distance from the keypad. The network can also be used for both remote
Authority Levels and PINs programming sessions with RPS and central station (ARC)
The system supports 32 Personal Identification Numbers reporting.
(PIN). The PIN default is four digits, but can range Event History Log
between three and seven digits. Designate an unlimited A 254-event history log keeps a record of open and close
number of master PINs. Use the master PINs to reprogram events, alarms, and troubles organized by time and date.
existing PINs. Program PINs using up to four different View the log information using the DS7447E and
authority levels, which can restrict the PIN from DS7447V2 LCD Keypads or RPS. The log also tracks the
bypassing, testing, and disarming the system. area, zone (device), user, and communication information
Locally or Remotely Programmable relevant to each event. All 254 events are in non-volatile
The system is completely keypad programmable memory.
(DS7447E or DS7447V2 Keypad required). An Installer's
Keypad feature is also available that allows quick access
to the programming menu.
DS7240V2 Control Panel | 3

Scheduled Events (Skeds) Certifications and Approvals


Skeds are programmed events that occur at a specific
time of day and day of week. These events include Auto
Region Certification
On, Auto Perimeter Only On, Auto Partial On, Auto Off and
Europe CE 1999/5/EC, 2006/95/EC, 2004/108/
Sked Output Function. Users can use the Extend Auto On
EC; EN 55022:2006 + A1:2007, Class B;
Time function to add an additional hour to the setting for
EN 50130-4 w/A1:1998 + A2:2003;
Auto On, Auto Perimeter Only On and Auto Partial On. EN61000-3-2:2006;
Depending on the assigned authority level, users can EN61000-3-3:1995; EN 60950-1:2001;
change a sked. Eight skeds are available. TBR21:1998
Fire Alarm Verification EN501-31 Compliance
The DS7240V2 Control Panel can automatically reset Russia GOST GOST 12997-84, GOST R MEK
smoke detectors after an initial alarm. If a second alarm 60065-2002, GOST R 50009-2000,
occurs within the verification window, an immediate fire GOST R 51317.3.2-99, GOST R
alarm results. This reduces potential false alarms, while 51317.3.3-99
still providing fast response to an alarm. France AFNOR NF, A2P (122076-00)
Door Access Control Modules (DACMs) China CCC DS7240V2-CHI: 2009031901000555
A DACM grants or restricts access through a door using a
Sweden INTYG 05-14
keypad, credential reader, Request-to-Exit (REX) input, or
a door contact. Each DACM replaces one system keypad 10-703 [-SWE]
and supervises one door. The DACM can also function as a Brazil ANATEL -EXP: 1240-05-1855
stand-alone device.
The DS7240V2 Control Panel complies with the following certifications,
Zones approvals, and standards.
The DS7240V2 accepts up to 40 zones in any combination Country Certification/Listing Number
of the available on-board zones, hard-wired expanded Europe EN50131-1 grade 2
zones, or wireless zones.
Sweden SSF 1014
Areas
The DS7240V2 can be divided into four independently-
configurable areas. Each area can have separate keypads
Installation/Configuration Notes
and a separate reporting ID.
Compatibility Information
Area 1 can be programmed as a common area that follows
the arming state of all the other areas. The common area Batteries D126 12 V, 7 Ah Standby Battery
arms only when all areas are armed. This allows for D1218 12 V, 18 Ah Standby Battery
protection of shared areas such as foyers and entryways, D1240 12 V, 4 Ah Standby Battery
while still maintaining separate areas. Keypads DS7445i LED Keypad
Outputs DS7445V2 LED Keypad
The DS7240V2 has four on-board programmable outputs DS7446KP LCD Keypad
that may be expanded up to 20.
DS7447E LCD Keypad
PO 1: terminals can be configured as an alarm power DS7447i Alpha Numeric Keypad
output. The default configuration for PO 1 makes it a dry
DS7447V2 LCD Keypad
contact, Normally-Open (NO) relay.
Fire D132A Smoke Detector Reversing Relay
PO 2: can be used with Alarm + as a supervised siren Detectors
driver. Connect an approved 4 Ω or 8 Ω speakers. DS250 Photoelectric Smoke Detector
Alternatively, PO 2 can sink up to 500 mA, 12 VDC. DS250TH Photoelectric Smoke Detector with
PO 3 and PO 4: can be configured for Alarm Output. heat-sensing thermistor
These outputs can sink 500 mA, 12 VDC each. DS284 Photoelectric Smoke Detector
DS284TH Photoelectric Smoke Detector with
heat-sensing thermistor
DS284THS Photoelectric Smoke Detector with heat-sensing
thermistor and sounder
Wireless RF280ETHS Wireless Photoelectric Smoke Detector with
Products heat-sensing thermistor and sounder

www.boschsecurity.com
4 | DS7240V2 Control Panel

RF835E Wireless TriTech® Detector Environmental Considerations

RF940E Wireless PIR Detector Relative Humidity: 5% to 85% at +30°C (+86°F) non-con-
RF1100E RF Glass Break Detector densing
RF3227E RF Receiver Temperature (Operating): 0°C to +49°C (+32°F to +120°F)
RF3332E Two-button Key Fob Keypads and Door Access Control Module (DACM)
RF3334E Four-button Key Fob
Number supported: 8 maximum in any combination of key-
RF3401E RF Transmitter pads or DACMs
RF3405E RF Inertia Transmitter
Power Outputs
RF3501E RF Panic Pendant
RF3503E RF Panic Button Continuous Power: 1.2 A maximum
Modules DACM Door Access Control Module Alarm Power: 1.85 A maximum at 11.5 VDC to
12.4 VDC
DX2010 Eight-input Expander
DX3010 Octo-output Expander Power Requirements
DX3011 Octo-output Expander Package Primary Voltage Input: 18 VAC, 50 VA transformer
DX3012 Octo-output Expander Package Secondary Voltage Input: Two 12 VDC, 7 Ah or 12 VDC, 18 Ah
DX4010 RS-232 Serial Interface Module sealed lead-acid rechargeable batteries
DX4010i RS-232 Serial Interface Module Current Requirements: 100 mA
DX4020 Network Interface Module Telephone Interface
RVM4C Remote Video Module
Telephone Interface: Terminal block
Wiring Considerations
Trademarks
• Up to 305 m (1,000 ft) allowed between control panel
external power supply and keypad or DACM when
using 0.8 mm wire. Windows® is either a registered trademark or trademark of
Microsoft Corporation in the United States and/or other countries.
• Up to 610 m (2,000 ft) allowed between panel/
external power supply and keypad or DACM when
using 1.2 mm wire.
• No more than two keypads or DACMs (0.8 mm) or Ordering Information
three keypads/DACMs (1.2 mm) are recommended on
any 305 m (1,000 ft) run when powered from the DS7240V2‑BEL Control Panel DS7240V2-BEL
panel. Dutch language version for Belgium.
DS7240V2‑BEF Control Panel DS7240V2-BEF
French language version for Belgium.
Parts Included DS7240V2‑CHI Control Panel DS7240V2-CHI
Chinese language version.
Each standard system includes:
DS7240V2‑EXP Control Panel DS7240V2‑EXP
Quantity Component Export version.
1 DS7240V2 control board DS7240V2‑FRA Control Panel DS7240V2-FRA
1 Universal enclosure French language version.
1 Transformer (18 VAC, 50 VA) DS7240V2‑DE Control Panel DS7240V2-DE
1 Hardware/resistor pack German language version.
DS7240V2‑IT Control Panel DS7240V2-IT
Italian language version.

Technical Specifications DS7240V2‑NL Control Panel DS7240V2-NL


Dutch language version.
Data Bus DS7240V2‑SPA Control Panel DS7240V2-SPA
Spanish language version.
Data Bus: 12 VDC nominal
DS7240V2‑SWE Control Panel DS7240V2-SWE
Enclosure Swedish language version.
Material: 1.0 mm, cold-rolled steel DS7240V2‑UK Control Panel DS7240V2-UK
Dimensions: 36.8 cm x 31.8 cm x 7.6 cm British English language version.
(14.5 in. x 12.5 in. x 3 in.)
DS7240V2 Control Panel | 5

www.boschsecurity.com
6 | DS7240V2 Control Panel

Americas: Europe, Middle East, Africa: Asia-Pacific: Represented by


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems
130 Perinton Parkway P.O. Box 80002 11 Bishan Street 21
Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943
Phone: +1 800 289 0096 Phone: + 31 40 2577 284 Phone: +65 6258 5511
Fax: +1 585 223 9180 Fax: +31 40 2577 330 Fax: +65 6571 2698
[email protected] [email protected] [email protected]
www.boschsecurity.us www.boschsecurity.com www.boschsecurity.asia

© Bosch Security Systems 2011 | Data subject to change without notice


T1605955467 | Cur: en-US, V10, 9 Aug 2011