HERNIS manufactures multi-cable solutions for CCTV systems that integrate data, video, and power transmission over a single cable. The multi-cables are designed to withstand harsh marine and offshore environments. HERNIS offers several multi-cable options that vary based on factors like operating temperature range, mechanical protection, and transmission requirements. The multi-cables aim to enhance CCTV installations by reducing time, materials, and environmental footprint compared to separate cabling.

Uploaded by

tqhunghn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
426 views3 pages

HERNIS CCTV Multi Cables

HERNIS manufactures multi-cable solutions for CCTV systems that integrate data, video, and power transmission over a single cable. The multi-cables are designed to withstand harsh marine and offshore environments. HERNIS offers several multi-cable options that vary based on factors like operating temperature range, mechanical protection, and transmission requirements. The multi-cables aim to enhance CCTV installations by reducing time, materials, and environmental footprint compared to separate cabling.

Uploaded by

tqhunghn
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

HERNIS CCTV Solutions

Multi Cables
HERNIS CCTV Multi Cables

Overview Features

To enhance installation, reduce man-hour and material costs and secure the  Purpose-designed
necessary quality of your CCTV system HERNIS offer our own range of CCTV
multi cables supplying both data video and power via the same cable. The multi  Supplies data, video and power
cables are designed specifically to survive a life time in harsh environments and
meet the requirements for onshore, offshore and marine installations complying
with the EMC regulations. Benefits

Depending on the project nature one or several of the HERNIS multi cables can  Time saving
be relevant for installation purposes. Below are the multi cables most commonly
used in HERNIS CCTV systems:  Reduction in use of Material

 Durable
• 025118 Ships cable with Screen
• 025119 Ships cable with Screen and Armour  Reduced environmental foot print
• 025106 Offshore cable with Screen  Long design life
• 025044 Offshore cable with Screen and Armour
• 020792 Flexible Crane-TV cable with Screen
• 025108 Crane-TV Cable with Screen
• 025122 Coax and Power
• 025223 Offshore cable Power & Cat 6 with Screen
• 025233 Power & Fibre with Screen
• 025333 Power & Fibre with Screen and Armour

A brief technical overview of each multi cable follows overleaf.

Our experienced team offer expert advice on the choice of multi cable ensuring
the optimal solution is found for your project. The cable is chosen for

• its ability to perform over time in the immediate physical environment that it
will be exposed to
• cable length and voltage level requirements
• tensile strength requirements
• mechanical protection requirements
• camera station power and signal requirements

HERNIS products’ long life cycle and low maintenance contributes to a minimal
environmental impact so vital in today’s global awareness.

*24 hour technical support line available for documented systems.

Eaton BE025118B p 1/3


HERNIS Scan Systems This document may be subject to change
[email protected] without further notice.
www.hernis.com EQS BUHER | Benefit sheet | Rev C | Date: 31.10.2014
HERNIS CCTV Solutions

Multi Cables
HERNIS CCTV Multi Cables

25118 Ships cable with Screen 25119 Ships cable with Screen and Armour
Coax: x2 Coax: x2
Power Conductors: x2 Power Conductors: x2
Twisted Pairs: x2 Twisted Pairs: x2
Sheath: Orange, Halogen free elastomer Sheath: Orange, Halogen free elastomer
Temp. Range Operating: -30°C ~ +80°C Temp. Range Operating: -60°C ~ +80°C (Installation: -30 ~ +80°C)
Mud Resistance: Resistant to Petro free drilling mud,NEK606 Mud Resistance: Resistant to Petro free drilling mud, NEK606
Flame Retardant to: IEC 60332-1 and -3, standard Flame Retardant to: IEC 60332-1 and -3, standard
Armour: 0.3mm galvanized steel wire braid

25106 Offshore cable with Screen 25044 Offshore cable with Screen and Armour
Coax: x2 Coax: x2
Power Conductors: x4 Power Conductors: x4
Twisted Pairs: x2 Twisted Pairs: x2
Sheath: Orange, Halogen free elastomer Sheath: Orange, Halogen free elastomer
Temp. Range Operating: -60°C ~ +80°C (Installation: -30 ~ +80°C) Temp. Range Operating: -60°C ~ +80°C (Installation: -30 ~ +80°C)
Mud Resistance: Resistant to Petro free drilling mud,NEK606 Mud Resistance: Resistant to Petro free drilling mud, NEK606
Flame Retardant to: IEC 60332-1 and -3, standard Flame Retardant to: IEC 60332-1 and -3, standard
Armour: 0.3mm galvanized steel wire braid

20792 Flexible Crane-TV cable with Screen 25108 Crane-TV Cable with Screen
Power Conductors: x4 Coax: x2
Twisted Pairs: x2 Power Conductors: x4
Twisted Pairs: x2 Twisted Pairs: x2
Sheath: Orange, Halogen free elastomer Sheath: Orange, Halogen free elastomer
Temp. Range Operating: -40°C ~ +90°C Temp. Range Operating: -60°C ~ +80°C (Installation: -30 ~ +80°C)
Resistance: Resistant to oils Mud Resistance: Resistant to Petro free drilling mud, NEK606
Flame Retardant to: IEC 60332-1 Flame Retardant to: IEC 60332-1 and -3, standard

Eaton BE025118B p 2/3


HERNIS Scan Systems This document may be subject to change
[email protected] without further notice.
www.hernis.com EQS BUHER | Benefit sheet | Rev C | Date: 31.10.2014
HERNIS CCTV Solutions

Multi Cables
HERNIS CCTV Multi Cables

25122 Coax and Power 25223 Offshore cable Power & Cat 6 with Screen
Coax: x1 Cat 6: x4 pairs
Power Conductors: x2 Power Conductors: x4
Sheath: Orange, Halogen free elastomer Sheath: Orange, Halogen free elastomer
Temp. Range Operating: -60°C ~ +80°C (Installation: -30 ~ +80°C) Temp. Range Operating: -25°C ~ +80°C
Mud Resistance: Resistant to Petro free drilling mud, Mud Resistance: Resistant to Petro free drilling mud, NEK606
NEK606 Flame Retardant to: IEC 60332-1 and -3, standard
Flame Retardant to: IEC 60332-1

25233 Power & Fiber with Screen 25333 Power & Fiber with Screen and Armour
Fiber: (2+2) Fiber: (2+2)
Power Conductors: (x3) Power Conductors: (x3)
Sheath: Orange, Halogen free elastomer Sheath: Orange, Halogen free elastomer
Temp. Range Operating: -30°C ~ +80°C Temp. Range Operating: -30°C ~ +80°C
Mud Resistance: Resistant to Petro free drilling mud, Mud Resistance: Resistant to Petro free drilling mud, NEK606
NEK606 Flame Retardant to: IEC 60332-1 and -3, standard
Flame Retardant to: IEC 60332-1 and -3, standard Armour: 0.3mm galvanized steel wire braid

Eaton BE025118B p 3/3


HERNIS Scan Systems This document may be subject to change
[email protected] without further notice.
www.hernis.com EQS BUHER | Benefit sheet | Rev C | Date: 31.10.2014

You might also like