0% found this document useful (0 votes)
43 views

DRWG 02

This document provides general notes for electrical installations, including: 1. Wiring shall be concealed in PVC conduit using appropriate copper wire sizes as indicated in the drawings. 2. Underground cables shall be buried a minimum of 750mm deep and enclosed in 75mm PVC pipes. 3. Device mounting heights shall be as follows: switches 1200mm, receptacles 450mm, TV/computer outlets 450mm, lighting switches 1300mm from finished floor level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views

DRWG 02

This document provides general notes for electrical installations, including: 1. Wiring shall be concealed in PVC conduit using appropriate copper wire sizes as indicated in the drawings. 2. Underground cables shall be buried a minimum of 750mm deep and enclosed in 75mm PVC pipes. 3. Device mounting heights shall be as follows: switches 1200mm, receptacles 450mm, TV/computer outlets 450mm, lighting switches 1300mm from finished floor level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Notes

ELECTRICAL -GENERAL NOTES


1.WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH 16.V SAT OUT DOOR EQUIPMENT SHALL BE DETERMINED ON
THESE DRAWINGS AND THE GENERAL SPECIFICATIONS FOR THE SITE WHILE ALL INDOOR UNITS SHALL BE
THE ELECTRICAL INSTALLATIONS IN THE FEDERAL POSITIONED AT THE BEST LOCATION IN THE RADIO
REPUBLIC OF NIGERIA AND INSTITUTION OF ELECTRICAL ROOM.ALL CABLES
ENGINEERS. TO UTILITY AREAS SHALL BE DONE NEATLY IN A CABLE
2.WIRING SHALL BE CONCEALED FULL PVC CONDUIT RUN IN TRAY.INSPECTION BOXES SHALL BE PROVIDED WITH
PVC INSULATED COPPER WIRE OF VARYING SIZES AS MAXIMUM SECURITY TO AVOID TAMPERING WITH THE
INDICATED ON THE WORKING DRAWINGS. INSTALLATIONS.
3.ALL CONDUIT PIPING SHALL BE CARRIED OUT WITH 17.PABX[AUTOMATIC PRIVATE BRANCH EXCHANGE] FOR Revisions

DIGNITY PIPES OF APPROPRIATE SIZES THE PROVISION OF TELEPHONE INTERCOM SERVICES

Approved
Designed
S/no.
Descriptions

Date
4.WIRING SHALL BE CARRIED OUT WITH NIGERIA WIRE SHALL BE LOCATED IN THE RADIO ROOM.ALL CABLES TO 1.

CABLES CERTIFIED OKAY BY THE CONSULTING ELECTRICAL DIFFERENT BLOCK OF BUILDINGS SHALL BE ENCLOSED IN 2.

3.

ENGINEER TRUNKING PIPES OF APPROPRIATE SIZES AND SHALL 4.

5.ALLUNDERGROUND ARMOURED CABLE SHALL BE EMBEDDED TERMINATE AT THE PLASTIC ADAPTABLE BOX. 5.

IN TIGER PIPE OF APPROPRIATE SIZES COMPLETE WITH 18.WHERE THE USE OF UNDERGROUND TELEPHONE CABLE IS
TAPE WARNING TO INDICATE THE CABLE POUTE INEVITABLE ,IT SHALL BE MARKED APPROPRIATELY WITH
6.ALL INTERCOM PIPES SHALL BE RUN IN 25MM DIAM.PVC CABLE MARKER WITH THE INSCRIPTION<TEL.CABLE>
CONDUIT PIPE 19.UNLESS OTHERWISE SHOWN ON THE
7.TELEPHONE DISTRIBUTION POINTS SHALL BE LINKED DRAWINGS,MOUNTING HEIGHT FROM FINISHED FLOOR
WITH THE MAIN DISTRIBUTION FRAME LEVEL TO THE CENTRE OF DEVICES SHALL BE AS FOLLOWS
8.DRAW WIRE ARE RECOMMENDED TO BE DRAWN INTO THE *LIGHTING
CONDUIT BOXES AND LIGHTING OUTLET TO AVOID SWITCHES..........................................................................1200MM
BLOCKAGE *INTERIOR
9.ALL LIGHTING SWITCHES SHALL BE 1300MM ABOVE RECEPTACLES.......................................................................450MM ar hi e s, planners, and pro e onsul an s
31, offa road, (goshen building)
TEL: g.r.a

FINISHED FLOOR LEVEL AN 150MM FROM THE DOOR FRAME *RECEPTACLES ABOVE 08033614144
08052219286.
p.o.box 5944,
ilorin.

10.ALL 13A SOCKET OUTLET SHALL BE 450MM ABOVE COUNTERS.........................................................1100MM


FINISHED FLOOR LEVEL AS LOCATED ON THE WORKING *TV
DRAWINGS OUTLETS.........................................................................................450MM Client:

11.ALL 15A[A/C] SOCKET OUT LET SHALL BE 1800MM ABOVE *TELEPHONE OBA ADEBIYI AFUNBIOWO II
FOUNDATION

FINISHED FLOOR LEVEL OR SPECIFIED OTHERWISE OUTLETS...........................................................................450MM


Project:

12.ALL UNDERGROUND CABLE SHALL BE ENCLOSED IN 75MM *COMPUTER PROPOSED STUDENTS HOSTEL

DIAM. UPVC HIGH PRESSURE PIPES OUTLETS............................................................................450MM AT FEDERAL UNIVERSITY OF


TECHNOLOGY,AKURE.

13.THE DEPTH OF CABLE BURRIED UNDERGROUND SHALL 20.WIRING FOR FIRE ALARM SYSTEM AND DETECTION MEP Consultant

DATA VISION
NOT BE LESS THAN 750MM ADOPTING STANDARD METHOD SYSTEM SHALL CONSIST OF FIRE CONSULTING ENGINEERS LTD
CIVIL,ELECTRICAL&MECHANICAL CONSULTING
AND CONTRACTING ENGINEERS
0PP.SAWMILL ALUGOKE COMPLEX,NEW YIDI ROAD,ILORIN

SPECIFIED BY IEE. RESISTANCE PVC INSULATED CONDUCTORS IN CONCEALED Drawing Title

14.CABLE MARKER SHALL BE PROVIDED TO IDENTIFY CABLE PVC CONDUIT PIPES. MINIMUM
ROUTE OF 1.5MM² PVC CABLE OR MINERAL INSULATED CABLES
(MICC) SHALL BE USED.
Job No Drawing Number Revision

15.WHERE MANHOLES ARE USED ,THE INVERT LEVEL SHALL


CONFORM WITH THE TOPOGRAPHY OF THE SITE Scale Date Drawn Approved

ELECTRICAL -NOTES