AC03 2.0 Reference Guide PDF Power Supply Capacitor
AC03 2.0 Reference Guide PDF Power Supply Capacitor
0 Reference
Guide
Facebook
(IL-NT AC03 unit) Twitter
SW version 2.0, June 2010
# Reference Guide
Email
Table of Contents
Table of Contents .................................................................................................................................... 2
General Guidelines.................................................................................................................................. 5
What describes this manual?.............................................................................................................. 5
!! Warnings !! ....................................................................................................................................... 5
Text ..................................................................................................................................................... 5
General Description................................................................................................................................. 7
Description of the controller system (with all options)......................................................................... 7
What is in the package?...................................................................................................................... 7
IL-NT RS232 Communication module ................................................................................................ 7
IL-NT RS232-485 Communication module ....................................................................................... 11
IL-NT S-USB Service USB communication module.......................................................................... 11
IB-Lite Ethernet communication plug-in card .................................................................................... 12
IL-NT-AOUT8 Gauge driver module ................................................................................................. 13
IL-NT RD Remote display software .................................................................................................. 14
IL-NT-EFCPM.................................................................................................................................... 14
IL-NT-EFCPM2 ................................................................................................................................. 15
Remote announciator IGL-RA15....................................................................................................... 15
IG-IOM/PTM module......................................................................................................................... 16
IG-IB Internet bridge.......................................................................................................................... 17
IL-NT Terminals and front fascia........................................................................................................... 18
IL-NT terminals and front fascia........................................................................................................ 18
Recommended Wiring........................................................................................................................... 19
AMF - Wiring Diagram....................................................................................................................... 19
Stand-by Applications............................................................................................................................ 20
Contactors (set point MCB Logic = “CLOSE-OFF”).......................................................................... 20
ATS with two stable positions (set point MCB Logic = “CLOSE-ON”) .............................................. 20
ATS with three stable positions (set point MCB Logic = “CLOSE-OFF”).......................................... 21
Getting Started ...................................................................................................................................... 22
How to install ..................................................................................................................................... 22
Current measurement ....................................................................................................................... 25
Earth Fault measurement (module) .................................................................................................. 26
Voltage measurement and generator connection types ................................................................... 28
Analog inputs..................................................................................................................................... 31
Extension modules (CAN bus) connection ....................................................................................... 34
Inputs and Outputs ................................................................................................................................ 36
Binary inputs IL-NT - default ............................................................................................................ 36
Binary inputs - list.............................................................................................................................. 36
Binary outputs IL-NT - default .......................................................................................................... 41
Binary outputs - list............................................................................................................................ 41
Analog inputs..................................................................................................................................... 52
Setpoints................................................................................................................................................ 53
Password........................................................................................................................................... 53
Basic Settings.................................................................................................................................... 53
Engine Params.................................................................................................................................. 57
Engine Protect................................................................................................................................... 62
Gener Protect.................................................................................................................................... 64
AMF Settings..................................................................................................................................... 67
Date/Time.......................................................................................................................................... 71
Sensors Spec.................................................................................................................................... 73
Extension I/O..................................................................................................................................... 73
SMS/E-Mail ....................................................................................................................................... 74
Man Operations................................................................................................................................. 76
Alternate Cfg ..................................................................................................................................... 77
ECU-controlled engine support ............................................................................................................. 79
Values read from ECU ...................................................................................................................... 80
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 2
AC03-2.0 Reference Guide.pdf
deltapsu.com
Learn More
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 3
AC03-2.0 Reference Guide.pdf
deltapsu.com
Learn More
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 4
AC03-2.0 Reference Guide.pdf
deltapsu.com
Learn More
General Guidelines
What describ es this manual?
This manual describes „AC03“ software, which is designed for single set, stand-by applications.
What is the purpose of the manual?
This manual provides general information how to install and operate InteliLite NT AC03 controller.
This manual is dedicated for
Operators of gen-sets
Gen-set control panel builders
For everybody who is concerned with installation, operation and maintenance of the gen-set
!! Warnings ! !
Remote contro l
InteliLite controller can be remotely controlled. In case of the work on the gen-set check, that nobody
can remotely start the engine.
To be sure:
Disconnect remote control via RS232 line
Disconnect input REM START/STOP
or
Disconnect output STARTER and outputs GCB CLOSE/OPEN and MCB CLOSE/OPEN
NT
Because of large variety of InteliLite parameters settings, it is not possible to describe any
combination. Some of InteliLite functions are subject of changes depend on SW version. The data in
this manual only describes the product and are not warranty of performance or characteristic.
Text
Note:
ComAp believes that all information provided herein is correct and reliable and reserves the right to
update at any time. ComAp does not assume any responsibility for its use unless otherwise expressly
undertaken.
Note:
SW and HW must be compatible otherwise the function will be disabled. If wrong software is
downloaded, message HARDWARE INCOMPATIBLE appears on controller screen. In this case use
Boot load (jumper) programming – close Boot jumper and follow instructions in LiteEdit, download
correct software.
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 5
AC03-2.0 Reference Guide.pdf
Switch InteliLite to MAN or OFF Mode or disconnect the Binary outputs Starter and
Fuel to avoid unexpected automatic start of gen-set and GCB closing.
Dangerous voltage
In no case touch the terminals for voltage and current measurement!
Always connect grounding terminals!
NT
In any case do not disconnect InteliLite CT terminals !
Ad ju st set poin ts
All parameters are preadjusted to their typical values. But the set points in the “Basic settings” settings
group !!must!! be adjusted before the first startup of the gen-set.
!!! WRONG ADJUSTMENT OF BASIC PARAMETERS
CAN DESTROY THE GEN-SET !!!
The follow ing instr uctions are for qualified personnel only. To avoid personal injury do
not perform any action not specified in this User guide !!!
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 6
AC03-2.0 Reference Guide.pdf
General Description
Description o f the contr oller system (with all opt ions)
NT
InteliLite AC03 is a comprehensive AMF-controller for single generating sets operating in stand-by
$
mode. IL-NT AC03 features extended support of electronic engines and extension modules.
Download now
NT
InteliLite controllers are equipped with a powerful graphic display showing icons, symbols and bar-
graphs for intuitive operation, which sets, together with high functionality, new standards in Gen-set
controls.
NT
InteliLite automatically starts the Gen-set, closes the Gen-set C.B. when all conditions are met, then
stops the engine on external signal or by pressing push buttons.
NT
InteliLite provides gas engine support without ventilation.
NT
The key feature of InteliLite is its easy-to-use operation and installation. Predefined configurations
for typical applications are available as well as user-defined configurations for special applications.
*Remote display for IL-NT controllers uses standard IL-NT controller with Remote display software.
**Supported from version IL-NT-AMF26-P-2.0.
Hint:
For detailed information about extension modules used with IL-NT controllers, please see the IL-NT-
Accessory Modules manual.
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 7
AC03-2.0 Reference Guide.pdf
Hint:
The following procedure is analogic also for other communication modules.
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 8
AC03-2.0 Reference Guide.pdf
4. Break apart the small cover into two pieces. Do not throw away the smaller part!
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 9
AC03-2.0 Reference Guide.pdf
Hint:
When you insert RS 232 communication module, the boot jumper is hidden. For that reason we
recommend to use RS 232 communication module with the boot jumper placed on it. See pictures
below:
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 10
AC03-2.0 Reference Guide.pdf
To insert the module, please follow the instructions for IL-NT RS232 module, procedure is analogous.
You must open the cover first (use screwdriver to open) and then insert the module into slot. Once you
have inserted it, the module will snap under plastic teeth. It is supposed to be installed permanently.
Should you need to remove it, the safest way is to remove whole back cover and than remove module
manually.
RS485 RS232
Boot jumper
RS485 Terminator jumper
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 11
AC03-2.0 Reference Guide.pdf
Hint:
Use the shielded USB A-B cable with this module! Recommended is ComAp cable – Order code:
“USB-LINK CABLE 1.8M”.
IB-Lite is a plug-in card with Ethernet 10/100 Mbit interface in RJ45 connector. The card is internally
connected to both COM1 and COM2 serial channels and provides an interface for connecting a PC
with LiteEdit or InteliMonitor through ethernet/internet network, for sending active e-mails and for
integration of the controller into a building management (Modbus TCP protocol).
This card also enables to monitor and control the genset over web browser from any location with
internet access using appropriate security measures.
Card inserts into “extension module” slot back on the controller. To insert the module, please follow
the instructions for IL-NT RS232 module, procedure is analogical.
Use Ethernet UTP cable with RJ45 connector for connection of the module into your ethernet network.
The module can be also connected directly to a PC using cross-wired UTP cable.
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 12
AC03-2.0 Reference Guide.pdf
Hint:
Modbus TCP protocol using IB-Lite communication module requires setting COM1 Mode = DIRECT
and COM2 Mode = MODBUS.
Hint:
The module requires some settings before initial usage. See IB-Lite-1.2-Reference Guide.pdf for more
details about IB-Lite communication plug-in card.
IL-NT-AOUT8 is optional plug-in card. Through this card controller can drive up to 8 VDO style
industrial/automotive gauges. Noncompensated gauges like 0-10V or 0-20mA are not supported.
Gauge type and value are configured in LiteEdit software. Any analog value from controller may be
shown in that way.
To insert the module, you must open the cover first (use screwdriver to open) and then insert the
module into slot. Once you have insert it, the module will snap under plastic teeth. It is supposed to be
installed permanently. Should you need to remove it, the safest way is to remove whole back cover
and than remove module manually.
Installing IL-NT-AOUT8 module is similar to installing RS 232 module. The difference is that IL-NT-
AOUT8 fits to “extension module” slot and after installing IL-NT-AOUT8 you do not put back the small
cover.
PC Installation Suite consist a set of prepared converting curves for basic usage of PWM outputs with
automotive gauges.
IL-NT-AOUT8 module:
NT
InteliLite AC03, SW version 2.0, ©ComAp – June 2010 13
AC03-2.0 Reference Guide.pdf