0% found this document useful (0 votes)
65 views6 pages

TeSys Deca Contactors - LC1D09M7

1. This document provides specifications for a TeSys D contactor that is a 3P(3 NO) AC-3 contactor rated for voltages up to 440 V and currents up to 9 A with a 220 V AC coil. 2. The contactor can be used for motor control and resistive loads up to 2.2 kW at various voltages from 220-690 V AC and frequencies of 50/60 Hz. 3. Key ratings include a rated operational voltage up to 690 V AC, rated operational current of 9 A at 440 V AC for AC-3 loads, and control circuit voltage of 220 V AC.

Uploaded by

Rudi Purnama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views6 pages

TeSys Deca Contactors - LC1D09M7

1. This document provides specifications for a TeSys D contactor that is a 3P(3 NO) AC-3 contactor rated for voltages up to 440 V and currents up to 9 A with a 220 V AC coil. 2. The contactor can be used for motor control and resistive loads up to 2.2 kW at various voltages from 220-690 V AC and frequencies of 50/60 Hz. 3. Key ratings include a rated operational voltage up to 690 V AC, rated operational current of 9 A at 440 V AC for AC-3 loads, and control circuit voltage of 220 V AC.

Uploaded by

Rudi Purnama
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Lembar data produk

Spesifikasi

TeSys D contactor - 3P(3 NO) -


AC-3 - <= 440 V 9 A - 220 V AC coil
LC1D09M7

Disklaimer: Dokumentasi ini tidak ditujukan sebagai pengganti dan tidak untuk digunakan untuk menentukan kesesuaian atau keandalan produk ini untuk aplikasi pengguna
Main
Range TeSys
TeSys Deca

Product name TeSys D


TeSys Deca

Product or component type Contactor

Device short name LC1D

Contactor application Motor control


Resistive load

Utilisation category AC-4


AC-3
AC-1
AC-3e

Poles description 3P

Power pole contact composition 3 NO

[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz


Power circuit: <= 300 V DC

[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)


4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)

Motor power HP (UL / CSA) 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
0.33 hp at 115 V AC 50/60 Hz for 1 phase motors

Control circuit type AC at 50/60 Hz

[Uc] control circuit voltage 220 V AC 50/60 Hz

Auxiliary contact composition 1 NO + 1 NC

[Uimp] rated impulse withstand 6 kV conforming to IEC 60947


voltage

Overvoltage category III

10 Mei 22 1
[Ith] conventional free air 25 A (at 60 °C) for power circuit
thermal current 10 A (at 60 °C) for signalling circuit

Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1

Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947

[Icw] rated short-time withstand 105 A 40 °C - 10 s for power circuit


current 210 A 40 °C - 1 s for power circuit
30 A 40 °C - 10 min for power circuit
61 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit

Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
25 A gG at <= 690 V coordination type 1 for power circuit
20 A gG at <= 690 V coordination type 2 for power circuit

Average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit

[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified

Electrical durability 0.6 Mcycles 25 A AC-1 at Ue <= 440 V


2 Mcycles 9 A AC-3 at Ue <= 440 V
2 Mcycles 9 A AC-3e at Ue <= 440 V

Power dissipation per pole 1.56 W AC-1


0.2 W AC-3
0.2 W AC-3e

Front cover With

Mounting support Plate


Rail

Standards CSA C22.2 No 14


EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1

Product certifications BV
LROS (Lloyds register of shipping)
UL
GOST
GL
DNV
CSA
RINA
CCC
UKCA

Connections - terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end

Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2

Operating time 12...22 ms closing


4...19 ms opening

Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Mechanical durability 15 Mcycles

2
10 Mei 22
Maximum operating rate 3600 cyc/h 60 °C

Complementary
Coil technology Without built-in suppressor module

Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz


0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz
1...1.1 Uc (60…70 °C):operational AC 50/60 Hz

Inrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)


70 VA 50 Hz cos phi 0.75 (at 20 °C)

Hold-in power consumption in 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)


VA 7 VA 50 Hz cos phi 0.3 (at 20 °C)

Heat dissipation 2…3 W at 50/60 Hz

Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1


type mirror contact 1 NC conforming to IEC 60947-4-1

Signalling circuit frequency 25...400 Hz

Minimum switching current 5 mA for signalling circuit

Minimum switching voltage 17 V for signalling circuit

Non-overlap time 1.5 ms on de-energisation between NC and NO contact


1.5 ms on energisation between NC and NO contact

Insulation resistance > 10 MOhm for signalling circuit

Environment
IP degree of protection IP20 front face conforming to IEC 60529

Climatic withstand conforming to IACS E10


conforming to IEC 60947-1 Annex Q category D

Protective treatment TH conforming to IEC 60068-2-30

Pollution degree 3

Ambient air temperature for -40…60 °C


operation 60…70 °C with derating

Ambient air temperature for -60…80 °C


storage

Operating altitude 0...3000 m

Fire resistance 850 °C conforming to IEC 60695-2-1

Mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz


Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 ms

Height 77 mm

Width 45 mm

Depth 86 mm

Net weight 0.32 kg

Packing Units
Unit Type of Package 1 PCE

Number of Units in Package 1 1

Package 1 Weight 351.0 g

Package 1 Height 5 cm

Package 1 width 9.5 cm

Package 1 Length 11 cm

Unit Type of Package 2 S02

10 Mei 22 3
Number of Units in Package 2 20

Package 2 Weight 7.261 kg

Package 2 Height 15 cm

Package 2 width 30 cm

Package 2 Length 40 cm

Unit Type of Package 3 P06

Number of Units in Package 3 320

Package 3 Weight 124.176 kg

Package 3 Height 75 cm

Package 3 width 80 cm

Package 3 Length 60 cm

Offer Sustainability
Sustainable offer status Green Premium product

REACh Regulation REACh Declaration

REACh free of SVHC Yes

EU RoHS Directive Compliant


EU RoHS Declaration

Toxic heavy metal free Yes

Mercury free Yes

RoHS exemption information Yes

China RoHS Regulation China RoHS declaration


 Pro-active China RoHS declaration (out of China RoHS legal scope)

Environmental Disclosure Product Environmental Profile

Circularity Profile End of Life Information

WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins

PVC free Yes

Contractual warranty
Warranty 12 months

4
10 Mei 22
Lembar data produk LC1D09M7
Dimensions Drawings

Dimensions

(1) Including LAD 4BB


(2) Minimum electrical clearance

LC1 D09…D18 D093…D123 D099…D129

b without add-on blocks 77 99 80

b1 with LAD 4BB 94 107 95.5

with LA4 D●2 110


(1)
123
(1)
111.5
(1)

with LA4 DF, DT 119


(1)
132
(1)
120.5
(1)

with LA4 DW, DL 126


(1)
139
(1)
127.5
(1)

c without cover or add-on blocks 84 84 84

with cover, without add-on blocks 86 86 86

c1 with LAD N or C (2 or 4 contacts) 117 117 117

c2 with LA6 DK10, LAD 6K10 129 129 129

c3 with LAD T, R, S 137 137 137

with LAD T, R, S and sealing cover 141 141 141

(1) Including LAD 4BB.

10 Mei 22 5
Lembar data produk LC1D09M7
Connections and Schema

Wiring

6
10 Mei 22