New Lifestyle Catalogue VRV Home Series
New Lifestyle Catalogue VRV Home Series
3 4
Project AL House ( BSD Tangerang ) Project Ayom Java Village ( Karanganyar - Jawa Tengah )
Designed by Atelier Riri Designed by Timtiga
AC Installed by Daikin Proshop AC Installed by Daikin Proshop
AC System Multi NX AC System VRV HS
5 6
Project Nava Park Lakewood ( BSD, Tangerang ) Project Lamp House ( Jakarta )
Designed by H Design Designed by Mozaic Architects
AC Installed by Daikin Proshop AC Installed by Daikin Proshop
AC System VRV HS AC System VRV HS
7 8
Project Nava Park Lakewood ( BSD, Tangerang ) Project Nava Park Lakewood ( BSD Tangerang )
Designed by H Design Designed by DHI / PT Dekorasi Hunian Indonesia
AC Installed by Daikin Proshop AC Installed by Daikin Proshop
AC System VRV HS AC System VRV HS & Multi NX
9 10
11 12
Because You’re Mat ter
C R E AT E Y O U R N E W L I F E S T Y L E W I T H D A I K I N P R O S H O P
Project
BENNY Project
FAJARAI CHEF
& ZILVIA YUDA
ISKANDAR BUSTARA
Financial Consultant
Design by Seisy Zakia
15 16
Project
Project
RUMAH CAFE
DINAS REUNI
WALIKOTA
Using Using
VRV HS MULTI NX
AC Installed by AC Installed by
Daikin Proshop Daikin Proshop
Project
Project
RUMAH PIK
CIPETE
Using Using
VRV IVS VRV HS
AC Installed by AC Installed by
Daikin Proshop Daikin Proshop
17 18
Project
Project PRIVATE
QUEBEC HOUSE
MANSION SUNTER
RESIDENCE
Designed by AS Design
Using Using
MULTI NX MULTI NX
AC Installed by
AC Installed by
Daikin Proshop
Daikin Proshop
Project
Project THE
YC HOUSE GARDEN
Designed by DP+HS Architects PIK
Designed by Einstein
& Associates
Using Using
VRV HS MULTI NX
AC Installed by AC Installed by
Daikin Proshop Daikin Proshop
19 20
Peace of mind
Refined Design for Modern Living. Exclusive and Compact Design
of DAIKIN’s Home Central with various capacity is created to meet
modern living which requires smaller space.
Capacity of home central air conditioning ranging from 4HP to 12HP in order to meet
different size of property and avoid any over & under size of cooling experience.
DAIKIN home central air conditioning outdoor comes in small size and it is easy to be placed
under the bay window and aircond ledge, so the apperance of buildings can be neat and
beautiful. Moreover, the new three pipes indoor machines can also be installed in landed
house and apartment, providing you comfort.
21 22
1
Advanced technology Unique design of dual electronic expansion valve, for precise balance control of
humidity and temperature
by DAIKIN Both of the two heat exchangers of indoor unit have independent electronic expansion valve to control
the refigerant flow, so as to achieve precise temperature control and up to third level of humidity
adjustment.
DAIKIN’s Home Central adopts the new technological breakthrough. Temperature and humidity
independent heat exchange structure
With additional third pipe (a high and low pressure pipe) from the original system,
DAIKIN’s Home Central can control essential elements such as humidity to fulfill Temperature and humidity
independent electronic expansion valve
Dual heat exchanger of reheat Dehumidification by common air 3D wing design for fan blade 4 4
Industrial areas Residential,
commercial,
Residential,
cultural and
Convalescence areas,
high-end villas,
conditioning 70 22
1
60
0
Fan 50
1 21 22
23 24
Refrigerant cooling technology Suppresses high harmonics and electrical noise
When the outdoor unit is running, the inverter motherboard will generate a lot of DAIKIN has been commited of using of inverter technology in
CoolMAX refigerant cooling Common air cooling Suppresses
heat. If the motherboard’s temperature rises to an abnormally high level, it will lead technology motherboard air conditioning systems, and it is especially experienced in the high
Sine wave circuit
Pulse circuit
to lower operating rates, and affect the overall stability of the system. In 2011, suppression of high harmonics and electrical noise. Through the harmonics
Electrodes double core and Power supply filtering
DAIKIN became the first to use Coolmax refrigerant cooling technology in the motherboard filter and combining a variety of other components Shielded sheath transmission electrical
industry, further enhancing the cooling efficiency of the inverter board through line
and measures, the generation of high harmonics and electrical noise
Ferrite ring
in-depth optimization of thermal design. Similar cooling technology has also been Small size, noise can be effectively inhibited.
used in a variety of high-tech electronic products, such as high-speed high thermal efficiency,
stable heat transfer
high-capacity computing computer.
High efficiency Reduce CO2 emissions that Control discharge of refrigerant to the Reduce negative effects caused
The ozone depletion potential
to ensure energy cause high energy atmosphere during stages of by the addition of refrigerant
(ODP) is zero
Common control board conservation consumption abandoned and operating. gas into the atmosphere
SMT * mounted technology
SMT protection on control board
123
25 2624
3Di+ / 3D+ / Compact+ Moisture Control Mode Kitchen
Ceiling Mounted Duct & Long Duct
FPEKQ20/28AV1/VM
FPRSQ-APV1/VM FPRAQ-APV1/VM FPRQ-APV1/VM
The balance control over temperature and humidity allows the human body to
feel more comfortable, and the intelligent model is even equipped with sensor
to detect human activity and floor temperature. The integrated design of decorative panel optimizes the kitchen’s ceiling
space, making installation more convenient; comprehensive oil proof structure
creates cool and comfortable cooking environment in kitchen.
3Di / 3D
FPDSQ-APV1/VM Bathroom
The angle of the horizontal and vertical louvers at the air outlet can be adjusted FPEBQ20AV1/VM
freely, ensuring a wide air supply angle. The high end panel highlight the high-end
identity and grade of users.
FPDQ80APV1
Walk In Closet
The indoor unit has compact body, with a thickness of only 200mm.
The depth of the standard model is only 450mm, and a variety of installation
methods is available to offer high freedom of design
FPECQ20AV1/VM
FXSQ-PAV
Protecting your private collection of bags and clothes from mould damage
with precise humidity control for your walk in closet.
Compact appearance, with a height of only 250mm and high external static
pressure, making it possible to be connected to long air duct. A variety of
installation methods that fit various occasions, especially large area spaces.
27 28
1
3/4 HP
to
2.5 HP
45~60%
Moisture Control Intelligent 3D Air Flow Ceiling Mounted Duct ( Type FPRSQ-APV1/VM )
Moisture Control 3D Air Flow Ceiling Mounted Duct ( Type FPRAQ-APV1/VM )
[ Sweet Dream Mode ]
Compact Moisture Control Ceiling Mounted Duct ( Type FPRQ-APV1/VM )
Dimensions ( H x W x D ) FPRSQ-APV1/VM With just a click of a button, the balanced
BRC1E642 temperature and humidity with 0.3 m/s*1 low
2.2 kW | 2.8 kW | 3.6 kW | 4.5 kW
velocity of air flow and the noise level as
200 x 700 x 620 mm
low as 17dB*2 create a more suitable
5.6 kW 7.1 kW environment for good night sleep.
200 x 900 x 620 mm 200 x 1100 x 620 mm
29 30
3/4 HP
to
2.5 HP
DAIKIN’s intelligent 3D panel, evenly dispersed air flow, fashionable intelligent eye
and personalised setting provide you a differentiated high-quality living environment
Air conditioning
Air conditioning
60°
45° 45°
Vertical louver: Move up & down from
0-60˚
Horizontal louver: Swing left & right at
Automatically controlled Angle can be freely 45˚
5.6 kW 7.1 kW
200 x 900 x 450 mm 200 x 1100 x 450 mm Sensor
Temperature
difference
Identifies that floor
Increase output
temperature is too low
31 32
3/4 HP
to
1.5 HP
BRC63A62
Wired Remote Function :
33 34
3/4 HP
IPX4
level
waterproofing
Ventilation Mode
( Rapid discharge of moisture and
odor to keep bathroom clean and fresh )
35 36
3/4 HP
19 20
37 38
3D Air Flow Ceiling Mounted Duct
Model Name FPRAQ20APV1 FPRAQ25APV1 FPRAQ32APV1
Power Supply V/Ph/Hz 220-240V/1Phase/50Hz
Cooling Capacity Kw 2.2 2.8 3.6
Power Consumption With Water Drain Pump W 33 33 36
Fan Mode/Cooling Mode Air Flow Rate (Hi/Med Hi/Med/Mid Lo/Lo) m3/min 7.2/6.8/6.3/5.8/5.4 8.3/7.4/6.8/6.3/5.8
Sound Level (Hi/Med Hi/Med/Mid Lo/Lo) dB(A) 29/27/26/25/23 32/31/29/27/25
Moisture Control Mode Air Flow Rate (Hi/Med Hi/Med/Mid Lo/Lo) m3/min 7.2/6.0/5.1/4.3/3.1 8.3/6.9/5.8/4.6/3.4
Sound Level (Hi/Med Hi/Med/Mid Lo/Lo) dB(A) 29/24/20/18/17 32/27/23/20/18
ESP (Hi/Std) Pa 10/0
Unit Dimension (HxWxD) mm 200 x 700 x 620
Discharge Dimension (HxW) mm 131 x 525
Unit Weight kg 24
Liquid Pipe/Gas Pipe mm φ6.4/φ12.7
Piping Connections High and Low Pressure Pipe mm
Condensate Drain Pipe mm PVC26(0.Dφ26/I.D.φ20)
Wired Remote Controller BRC1E642
21 22
39 40
LONG Middle Static Ceiling Mounted Duct
Model Name FXSQ20PAV4 FXSQ25PAV4 FXSQ32PAV4 FXSQ40PAV4 FXSQ50PAV4
Power Supply V/Ph/Hz 220-240V/1Phase/50Hz,60Hz
Cooling Capacity Kw 2.2 2.8 3.6 4.5 5.6
Power Consumption W 58 66 101 75
Fan Mode/Cooling Mode Air Flow Rate (Hi/Med/Lo) m3/min 9/7.5/6.5 9.5/8/7 15/12.5/10.5 17/14.5/11.5
Sound Level (Hi/Med/Lo) dB(A) 33/30/28 34/32/30 36/33/30 34/32/29
ESP (Hi/Std) Pa 30-150 (50) 50-150 (50)
Unit Dimension (HxWxD) mm 245x550x800 245x700x800 245x1000x800
Unit Weight kg 25 27 35
Liquid Pipe/Gas Pipe mm φ6.4/φ12.7
Piping Connections
Condensate Drain Pipe mm PVC26(0.Dφ26/I.D.φ20)
Wired Remote Controller BRC1E63 Ceiling Mounted Duct
Wireless Remote Controller BRC4C66
Model Name FXDQ20SPV14 FXDQ25SPV14 FXDQ32SPV14 FXDQ40SPV14 FXDQ50SPV14 FXDQ63SPV14
Model Name FXSQ63PAV4 FXSQ80PAV4 FXSQ100PAV4 FXSQ125PAV4 FXSQ140PAV4 Power Supply V/Ph/Hz 220-240V/1Phase/50Hz
Power Supply V/Ph/Hz 220-240V/1Phase/50Hz,60Hz Cooling Capacity Kw 2.2 2.8 3.6 4.5 5.6 7.1
Cooling Capacity Kw 7.1 9 11.2 14 16 Power Consumption W 72 75 78 180 196
Power Consumption W 106 126 151 206 222 Fan Mode/ Air Flow Rate (Hi/Med Hi/Med/Mid Lo/Lo) m3/min 8.7/7.6/6.5 9/8/7 10/9/8 15/13/10.5 20/16/12.5
Cooling Mode Sound Level (Hi/Med Hi/Med/Mid Lo/Lo) dB(A) 33/31/29 34/32/30 35/33/31 37/35/33
Fan Mode/Cooling Mode Air Flow Rate (Hi/Med/Lo) m3/min 21/17.5/14.5 23/19.5/16 32/27/22.5 37/31.5/26 39/33.5/28
ESP (Hi/Std) Pa 30-10 50-20 40-20
Sound Level (Hi/Med/Lo) dB(A) 36/32/29 37.5/34/30 39/35/32 42/38.5/35 43/40/36
Unit Dimension (HxWxD) mm 200x700x450 200x900x450 200x1,100x450
ESP (Hi/Std) Pa 50-150 (50) 50-140 (50)
Unit Weight kg 17 20 23
Unit Dimension (HxWxD) mm 245x1,000x800 245x1,400x800 245x1,550x800 φ6.4/φ12.7
Liquid Pipe/Gas Pipe mm φ9.5/φ15.9
Unit Weight kg 35 37 46 47 52 Piping Connections
Condensate Drain Pipe mm PVC26(0.Dφ26/I.D.φ20)
Liquid Pipe/Gas Pipe mm φ9.5/φ15.9 Wired Remote Controller BRC1E63
Piping Connections
Condensate Drain Pipe mm PVC26(0.Dφ26/I.D.φ20)
Wired Remote Controller BRC1E63
Wireless Remote Controller BRC4C66
23 24
41 42
Ceiling Mounted Duct
Model Name FPRQ20APVM FPRQ25APVM FPRQ32APVM
Power Supply V/Ph/Hz 220-240V/1Phase/50Hz
Cooling Capacity Kw 2.2 2.8 3.6
Power Consumption With Water Drain Pump W 33 36
Fan Mode/Cooling Air Flow Rate (Hi/Med Hi/Med/Mid Lo/Lo) m3/min 7.2/6.8/6.3/5.8/5.4 8.3/7.4/6.8/6.3/5.8
Mode Sound Level (Hi/Med Hi/Med/Mid Lo/Lo) dB(A) 29/27/26/25/23 32/31/29/27/25
Moisture Control Mode Air Flow Rate (Hi/Med Hi/Med/Mid Lo/Lo) m3/min 7.2/6.0/5.1/4.3/3.1 8.3/6.9/5.8/4.6/3.4
Sound Level (Hi/Med Hi/Med/Mid Lo/Lo) dB(A) 29/24/20/18/17 32/27/23/20/18
ESP (Hi/Std) Pa 30/10
Unit Dimension (HxWxD) mm 200X700X620
Discharge Dimension (HxW) mm 153X660
Unit Weight kg 24
Piping Connections Liquid Pipe/Gas Pipe mm φ6.4/φ12.7
High and Low Presssure Pipe mm φ9.5
Wired Remote Controller BRC1E642
25 26
43 44
Ventilating Moisture Control
Bathroom Ceiling Mounted Cassette
33 34
25
45 46
26
Model Name RPZQ4AVM RPZQ5AVM RPZQ6AVM
Power Supply V/Ph/Hz 220-240V/1Phase/50Hz
Cooling Capacity kW 11.2 14 15.5
Power Consumption kW 2.87 3.62 4.19
Air Flow Rate (Hi/Med//Lo) m3/min 76 106
Unit Dimension (HxWxD) mm 990 x 940 x 320 1345 x 900 x 320
Unit Weight kg 80 104
Sound Level dB(A) 53 51
Operating Range -5 - 50⁰CDB
Piping Connections Liquid Pipe/Gas Pipe mm φ9.5/φ15.9 φ9.5/φ19.1
High-Low Pressure Pipe φ12.7
Condensate Drain Pipe mm φ12.7
Max. Amount connection ofIndoor Unit 6 8 9
kW 5.6-14.5 7.0-20.1 7.7-20.1
Connection Capacity
% 50-130
29 30
47 48
49 32
50
51 52
System for Residential, Small Offices and Shops S SERIES
VRV
4, 5 HP
S
S SERIES 4 HP
4, 5 HP VRV
4 HP
S (11.2 kW) S SERIES (11.2 kW)
a
Actual piping length b c d
Max. 120 m First indoor branch
e f g h i
Total piping length Max.
Max. 300 m 50 m k
Max.
j 15 m
4 HP 5 HP 6 HP 8,9 HP
External view of Refrigerant piping length a+b+c+d+i 50 m 70 m 120 m 100 m
a condominium Max. allowable piping
Total piping length a+b+c+d+e+f+g+h+i 250 m 300 m 300 m 300 m
length
Between the first indoor branch and the farthest indoor unit b+c+d+i 40 m 40 m 40 m 40 m
Internal view of a
condominium unit
53 54
Cutting-edge Technologies S SERIES
12% Daikin DC inverter models are equipped with the Reluctance DC motor for compressor.
Increase The Reluctance DC motor uses 2 different types of torque, neodymium magnet*1 and
reluctance torque*2. This motor can save energy because it generates more power with
Cooling
Operation
4 3.89 3.86 a smaller electric power than an AC or conventional DC motor.
COP 3.8 3.77
3.6 3.56 3.49 Reluctance DC motor
*Cooling operation conditions: Indoor temp. of 27ºCDB,19ºCWB, and outdoor temp. of 35ºCDB.
AC motor
60
VRV S 50
0 30 60 90 60
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory using Daikin products.
Quiet operation *1 A neodymium magnet is approximately 10 times stronger than a standard ferrite magnet.
*2 The torque created by the change in power between the iron and magnet parts. Sine wave DC inverter
Mode 1. Automatic mode Mode 1. Automatic mode >> Swing compressor >> The structural scroll Suction
Set on the outdoor PCB. Time of maximum temperature is memorised. Daikin swing compressor has integrated the Sucked gas is
The low operating mode will initiate 8 hours*1 after the peak temperature
rotor with the blade, completely solving the compressed in the
Load % Capacity %
in the daytime, and normal operation will resume 10 hours*2 after that. Scroll section
These two features work to reduce sound. Guides are added to the Efficiency improved in all areas
Step 1 max. - 3 dB(A) Step 1: 49 dB(A)
Mode 3. Combined mode bell mouth intake to reduce turbulence in the airflow generated by compared to conventional AC
49
fan suction. The Aero Spiral Fan features fan blades with the bent motors, especially at low speeds.
Combinations of modes 1 and 2 can be used depending on your needs. Step 2 max. - 6 dB(A) Step 2: 46 dB(A) blade edges, further reducing turbulence. DC fan motor structure
46
With the bent Without the bent
Step 3 max. - 9 dB(A) Step 3: 43 dB(A)
blade edge blade edge
*1. Initial setting. Can be selected from 6, 8 and 10 hours. 43
*2. Initial setting. Can be selected from 8, 9 and 10 hours. Night mode starts Night mode ends
*3. In case of 4 HP outdoor unit during cooling operation
8:00 12:00 16:00 20:00 0:00 4:00 8:00
55 56
Indoor Unit Lineup
Daikin offers a wide range of indoor units includes both VRV and residential models responding Wall Mounted Type Floor Standing Type
to variety of needs of our customers that require air-conditioning solutions. FXAQ-AVM FXLQ-MAVE4
FXFSQ-AV4
FXFQ-AV4
Floor Standing Duct
Type
FXVQ-NY14
Presence of people and floor 360° airflow improves temperature
temperature can be detected to provide distribution and offers a comfortable
comfort and energy savings. living environment.
FXKQ-MAVE4 FXDQ-PDVE(T)4
FXDQ-NDVE(T)4
VRV indoor units connections
Slim design for flexible installation Slim design, quietness and
static pressure switching
FXDQ-SPV14 FXSQ-PAV4
Max.
Max.
FXMQ-PAV4 FXHQ-MAV7
FXMQ-MAV4
FXMQ-PVM
FXHQ-AVM4
High external static pressure
allows flexible installations Slim body with quiet and wide airflow
57 58
New Round Flow
FXFSQ-A FXFQ-A
Quiet, compact, and designed for user comfort
Round flow
with sensing
Specifications
MODEL FXZQ20MVE4 FXZQ25MVE4 FXZQ32MVE4 FXZQ40MVE4 FXZQ50MVE4
Wide variety of decoration panels (Option) Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100
Designer choice has been given a boost with the increase in number of new types of decoration panels. Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6
Power consumption kW 0.073 0.076 0.089 0.115
Casing Galvanised steel plate
Sound level 230 V, 50 Hz- dB(A) 30/25-32/26 32/26-34/28 36/28-37/29 41/33-42/35
(H/L) 240 V, 50 Hz
Dimensions (H×W×D) mm 286×575×575
Machine weight kg 18
- Fresh White - - Black - - Fresh White - - Fresh White - - Black - Ceiling Mounted Cassette (Double Flow) Type FXCQ-AVM4
Power supply
MODEL FXFSQ25AV4 FXFSQ32AV4 FXFSQ40AV4 FXFSQ50AV4 FXFSQ63AV4 FXFSQ80AV4
1-phase, 220 -240 V/220-230 V, 50/60 Hz
FXFSQ100AV4 FXFSQ125AV4 FXFSQ140AV4 Ceiling Mounted Cassette Corner Type FXKQ-MA
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
Power consumption kW 0.028 0.035 0.038 0.061 0.092 0.144 0.170 0.194
Casing Galvanised steel plate Slim design for flexible installation
Sound level (H/HM/M/ML/L) dB(A) 30/29.5/28.5/28/27 35/29.5/29/28/27 38/35/34.5/29.5/27 38/36/35.5/31.5/28 39/37/36/35.5/31 44/41/38/35/33 45/42.5/39.5/37/35 46/43.5/40.5/38/35
Dimensions (H×W×D)
Machine weight
mm
kg 19
256×840×840
24 22 25
298×840×840
26
Specifications
MODEL FXKQ25MAVE4 FXKQ32MAVE4 FXKQ40MAVE4 FXKQ63MAVE4
Ceiling Mounted Cassette (Round Flow) Type
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
MODEL FXFQ25AV4 FXFQ32AV4 FXFQ40AV4 FXFQ50AV4 FXFQ63AV4 FXFQ80AV4 FXFQ100AV4 FXFQ125AV4 FXFQ140AV4
Cooling capacity Btu/h 9,600 12,300 15,400 24,200
Power supply 1-phase, 220 - 240 V/220-230 V, 50/60 Hz
Power consumption kW 0.066 0.076 0.105
Cooling capacity Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
220 V 38/33 40/34 42/37
Power consumption kW 0.029 0.036 0.040 0.063 0.096 0.158 0.178 0.203 Sound level (H/L) dB(A)
Casing Galvanised steel plate
240 V 40/35 42/36 44/39
Sound level (H/HM/M/ML/L) dB(A) 30/29.5/28.5/28/27 35/29.5/29/28/27 35/33.5/29.5/28.5/27 36/35.5/31.5/31/28 37/36.5/36/35.5/29.5 43/40.5/37.5/35/33 44/41.5/39/36.5/33 46/43.5/40.5/38/35 Dimensions (H×W×D) mm 215X1,110X710 215X1,310X710
Dimensions (H×W×D) mm 256×840×840 298×840×840 Machine weight kg 31 34
Machine weight kg 19 22 25 26 Note: Specifications are based on the following conditions;
Note: Specifications are based on the following conditions; •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) (See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. •Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
59 60
Indoor Unit Lineup VRV Indoor Units
Slim Ceiling Mounted Duct Type (Standard Series) FXDQ-PD / ND Ceiling Mounted Duct Type FXMQ-PA / MA / P
Specifications
Specifications MODEL FXMQ20PAV4 FXMQ25PAV4 FXMQ32PAV4 FXMQ40PAV4 FXMQ50PAV4
with drain pump FXDQ20PDVE4 FXDQ25PDVE4 FXDQ32PDVE4 FXDQ40NDVE4 FXDQ50NDVE4 FXDQ63NDVE4 Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
MODEL
without drain pump FXDQ20PDVET4 FXDQ25PDVET4 FXDQ32PDVET4 FXDQ40NDVET4 FXDQ50NDVET4 FXDQ63NDVET4 Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Power consumption kW 0.056 1 0.056 1 0.060 1 0.151 1 0.128 1
Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 16/13/11 18/16.5/15
Power consumption Airflow rate (HH/H/L)
(FXDQ-PDVE) 1 kW 0.086 0.086 0.089 0.160 0.165 0.181 cfm 318/265/230 318/265/230 335/282/247 565/459/388 635/582/530
External static pressure Pa 30-100 (50) 2 30-100 (50) 2 30-100 (50) 2 30-160 (100) 2 50-200 (100) 2
Power consumption
kW 0.067 0.067 0.070 0.147 0.152 0.168 Sound level (HH/H/L) dB(A) 33/31/29 33/31/29 34/32/30 39/37/35 41/39/37
(FXDQ-PDVET) 1
Dimensions (H×W×D) mm 300x550x700 300x550x700 300x550x700 300x700x700 300x1,000x700
External static pressure Pa 30-10 2
44-15 2
Machine weight kg 25 25 25 27 35
Sound level (HH/H/L) 1 3 dB(A) 28/26/23 28/26/24 30/28/26 33/30/27 33/31/29
Dimensions (H×W×D) mm 200×700×620 200×700×620 200×700×620 200×900×620 200×900×620 200×1,100×620 MODEL FXMQ63PAV4 FXMQ80PAV4 FXMQ100PAV4 FXMQ125PAV4 FXMQ140PAV4
Machine weight kg 23 23 23 27 28 31 Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Note: Specifications are based on the following conditions; Cooling capacity Btu/h 24,200 30,700 38,200 47,800 54,600
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. Power consumption
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
kW 0.138 1 0.185 1 0.215 1 0.284 1 0.405 1
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. m /min
3
19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32
During actual operation, these values are normally somewhat higher as a result of ambient conditions. Airflow rate (HH/H/L)
1 : Values are based on the following conditions: FXDQ-PD: external static pressure of 10 Pa; FXDQ-ND: external static pressure of 15 Pa. cfm 688/618/565 883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130
2 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is
10 Pa for FXDQ-PD models and 15 Pa for FXDQ-ND models.) External static pressure Pa 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-200 (100) 2 50-140 (100) 2
3 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
Sound level (HH/H/L) dB(A) 42/40/38 43/41/39 43/41/39 44/42/40 46/45/43
Dimensions (H×W×D) mm 300×1,000×700 300×1,000×700 300×1,400×700 300×1,400×700 300×1,400×700
Machine weight kg 35 35 45 45 46
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
FXDQ-SP •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32PA), thirteen (FXMQ40PA), fourteen (FXMQ50-125PA) or ten (FXMQ140PA) levels of
control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32PA and 100 Pa for FXMQ40-140PA.
MODEL FXDQ20SPV14 FXDQ25SPV14 FXDQ32SPV14 FXDQ40SPV14 FXDQ50SPV14 FXDQ63SPV14 MODEL FXMQ200MAV4 FXMQ250MAV4 FXMQ200PVM FXMQ250PVM
Power supply 1-phase, 220-240 V, 50 Hz Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Cooling capacity Btu/h 76,400 95,500 76,400 95,500
Power consumption 1 kW 0.072 0.075 0.078 0.180 0.180 0.196 1 1 1 1
Power consumption kW 1.294 1.465 0.55 0.67
m3/min 8.7/7.6/6.5 9.0/8.0/7.0 10.0/9.0/8.0 15.0/13.0/10.5 20.0/16.0/12.5
Airflow rate (HH/H/L) m3/min 58/50 72/62 61/50 71/58
cfm 307/268/229 318/282/247 353/318/282 530/459/371 706/565/441 Airflow rate (H/L)
cfm 2,047/1,765 2,542/2,189 2,153/1,765 2,506/2,047
External static pressure Pa 30-10 2 50-20 2 40-20 2
External static pressure Pa 132-221 2 191-270 2 50-250 (150) 2 50-250 (150) 2
Sound level (HH/H/L) 1 3 dB(A) 33/31/29 34/32/30 35/33/31 37/35/33
220 V 48/45 48/45 38/35 40/37
Dimensions (H×W×D) mm 200×700×450 200×900×450 200×1,100×450 Sound level (H/L) dB(A)
Machine weight kg 17 20 23 240 V 49/46 49/46 - -
Dimensions (H×W×D) mm 470×1,380×1,100 470×1,380×1,100 470×1,490×1,100 470×1,490×1,100
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. Machine weight kg 137 137 95 105
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
Note: Specifications are based on the following conditions;
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
1 : Values are based on the following conditions: FXDQ20-32SP: external static pressure of 10 Pa; FXDQ40-63SP: external static pressure of 20 Pa. • Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
2 : External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factorysetting is 10 Pa for FXDQ20-32SP models and 20 Pa for During actual operation, these values are normally somewhat higher as a result of ambient conditions.
FXDQ40-63SP models.) 1: Power consumption values are based on conditions of standard external static pressure.
3 : The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".
61 62
Indoor Unit Lineup VRV Indoor Units
Middle Static Pressure Ceiling Mounted Duct Type FXSQ-PA Ceiling Suspended Type FXHQ-MA / A
Specifications Specifications
MODEL FXSQ20PAV4 FXSQ25PAV4 FXSQ32PAV4 FXSQ40PAV4 FXSQ50PAV4 Note: Specifications are based on the following conditions; MODEL FXHQ32MAV7 FXHQ63MAV7 FXHQ100MAV7 FXHQ125AVM4 FXHQ140AVM4
•Cooling: Indoor temp.: 27°CDB, 19°CWB,
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Outdoor temp.: 35°CDB, Equivalent piping
Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 length: 7.5 m, Level difference: 0 m.
Cooling capacity Btu/h 12,300 24,200 38,200 48,000 52,900
Power consumption kW 0.058 1
0.058 1 0.066 1 0.101 1
0.075 1 •Capacity of indoor unit is only for reference. Actual
capacity of indoor unit is based on the total Power consumption kW 0.111 0.115 0.135 0.168 0.181
m3/min 9/7.5/6.5 9/7.5/6.5 9.5/8/7 15/12.5/10.5 17/14.5/11.5 capacity index. (See Engineering Data Book for
Airflow rate (H/M/L) m3/min 12/10 17.5/14 25/19.5 34/20 36/20
cfm 318/265/230 318/265/230 335/282/247 530/441/371 600/512/406 details.)
Airflow rate (H/L)
•Sound level: Anechoic chamber conversion value, cfm 424/353 618/494 883/688 1,200/706 1,271/706
External static pressure Pa 30-150 (50) 2 50-150 (50) 2
measured at a point 1.5 m downward from the
Sound level (H/M/L) dB(A) 33/30/28 34/32/30 36/33/30 34/32/29 unit centre. Sound level (H/L) dB(A) 36/31 39/34 45/37 46/37 48/37
Dimensions (H×W×D) mm 245×550×800 245×700×800 245×1,000×800 During actual operation, these values are
normally somewhat higher as a result of ambient Dimensions (H×W×D) mm 195×960×680 195×1,160×680 195×1,400×680 235×1,590×690 235×1,590×690
Machine weight kg 25 27 35 conditions. Machine weight kg 24.0 28.0 33.0 39.0
1: Power consumption values are based on
MODEL FXSQ63PAV4 FXSQ80PAV4 FXSQ100PAV4 FXSQ125PAV4 FXSQ140PAV4 conditions of rated external static pressure. Note: Specifications are based on the following conditions;
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz 2: External static pressure can be modified using • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
a remote controller that offers thirteen • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Cooling capacity Btu/h 24,200 30,700 38,200 47,800 54,600 (FXSQ20-40PA), eleven (FXSQ50-125PA) (See Engineering Data Book for details.)
Power consumption kW 0.106 1
0.126 1
0.151 1
0.206 1
0.222 1 or ten (FXSQ140PA) levels of control. These • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
values indicate the lowest and highest possible During actual operation, these values are normally somewhat higher as a result of ambient conditions.
m3/min 21/17.5/14.5 23/19.5/16 32/27/22.5 37/31.5/26 39/33.5/28 static pressures. The rated static
Airflow rate (H/M/L)
cfm 741/618/512 812/688/565 1,130/953/794 1,306/1,112/918 1,377/1,183/988 pressure is 50 Pa.
External static pressure Pa 50-150 (50) 2 50-140 (50) 2
Sound level (H/M/L) dB(A) 36/32/29 37.5/34/30 39/35/32 42/38.5/35 43/40/36
Dimensions (H×W×D) mm 245×1,000×800 245×1,400×800 245×1,550×800
Machine weight kg 35 37 46 47 52
Stylish flat panel design harmonised Suitable for perimeter zone air conditioning
with your interior décor
Specifications
MODEL FXAQ20AVM(4)(S) FXAQ25AVM(4)(S) FXAQ32AVM(4)(S) FXAQ40AVM(4)(S) FXAQ50AVM(4)(S) FXAQ63AVM(4)(S) Specifications
VM: 1-phase, 220-240 V/220-230 V, 50/60 Hz MODEL FXLQ20MAVE4 FXLQ25MAVE4 FXLQ32MAVE4 FXLQ40MAVE4 FXLQ50MAVE4 FXLQ63MAVE4
Power supply
VM4, VMS: 1-phase, 220 V, 50 Hz
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Power consumption kW 0.040 0.050 0.060 0.100 Power consumption kW 0.049 0.049 0.090 0.090 0.110 0.110
m3/min 9.1/7.0 9.4/7.0 9.8/7.0 12.2/9.7 15.0/12.0 19.0/14.0 m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12
Airflow rate (H/L) Airflow rate (H/L)
cfm 321/247 332/247 346/247 431/342 530/424 671/494 cfm 247/212 247/212 282/212 388/300 494/388 565/424
Sound level (H/L) dB(A) 33.0/28.5 35.0/28.5 37.5/28.5 37.0/33.5 41.0/35.5 46.5/38.5 220 V 35/32 35/32 35/32 38/33 39/34 40/35
290×795×266 290×1,050×269 Sound level (H/L) dB(A)
Dimensions (H×W×D) mm 240 V 37/34 37/34 37/34 40/35 41/36 42/37
Machine weight kg 12.0 15.0 Dimensions (H×W×D) mm 600×1,000×222 600×1,000×222 600×1,140×222 600×1,140×222 600×1,420×222 600×1,420×222
Note: Specifications are based on the following conditions; Machine weight kg 25.0 25.0 30.0 30.0 36.0 36.0
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. Note: Specifications are based on the following conditions;
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
(See Engineering Data Book for details.) •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. (See Engineering Data Book for details.)
During actual operation, these values are normally somewhat higher as a result of ambient conditions. •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
63 64
Indoor Unit Lineup Air Treatment Equipment
Floor Standing Duct Type FXVQ-N PM2.5 filtration unit
Double-layered efficient filtration
Large airflow type for large spaces. PM2.5 filters are double-layered. Front Filter
Highly Efficient Filter
1. The front filter effectively removes large particles.
Flexible interior design for each tenant. 2. The PM2.5 filter layer contains a large amount of static
electricity to capture particulate matter efficiently.
Optional :
Specifications Active Carbon Fltration Unit
EA
MODEL FXVQ125NY14 FXVQ200NY14 FXVQ250NY14 (Exhaust air to outdoors)
RA
OA
Power supply 3-phase 4-wire system, 380–415 V, 50 Hz (Fresh air from
(Return air
from room)
outdoors)
Cooling capacity Btu/h 47,800 76,400 95,500
Power consumption kW 0.53 1.33 1.61
Air Treatment Equipment Heat Reclaim Ventilator remote controller*
BRC301B61 (Option) SA
Dimensions (H×W×D) mm 1,670×750×510 1,670×950×510 1,670×1,170×510
Improve your indoor air quality
(Supply air
* This remote controller is used in case of independent to room)
Machine weight kg 118 144 169 operation of Heat Reclaim Ventilator.
Heat
Exchange High dB(A) 26-27.5/27.5 26-27.5/28 30-31.5/30 31.5-34/32 33-34.5/34 37-39.5/37.5 37.5-39.5/37.5 37.5-39.5/39.5 39-43/40
Mode
Sound Level Low 20.5-21.5/21 21-22/21 23-25/23 25-28.5/24 27.5-29.5/28 35-37.5/34 35-37.5/34.5 35-37.5/36 36-39/39
Designed to be concealed (50/60 Hz) Ultra-High 28.5-29.5/29.5 28.5-30.5/30.5 33-34.5/34.5 34.5-36/35.5 35-37.5/37.5 40.5-42/41 40.5-42.5/40.5 41-43/42.5 43-45.5/44
Bypass
High dB(A) 27.5-28.5/28.5 27.5-29/29.5 31.5-33/31.5 33-34.5/33.5 33-35.5/35.5 38.5-40/39 38.5-40.5/38.5 39.5-41/41.5 40.5-45/42
in the perimeter skirting-wall Mode
Low 22.5-23.5/22 22.5-23/22.5 24.5-26.5/24.5 25.5-28.5/25.5 27.5-30.5/29.5 36-38.5/35.5 36-38.5/35.5 36.5-38/37.5 37.5-39.5/41
Casing Galvanised steel plate
Insulation Material Self-extinguishable polyurethane foam
Dimensions (HXWXD) mm 278X810X551 306X879X800 338X973X832 387X1,111X832 387X1,111X1,214 785X1,619X832 785X1,619X1,214
Specifications Machine Weight kg 24 32 45 55 67 129 157
MODEL FXNQ20MAVE4 FXNQ25MAVE4 FXNQ32MAVE4 FXNQ40MAVE4 FXNQ50MAVE4 FXNQ63MAVE4 Heat Exchange System Air to air cross flow total heat (Sensible heat + latent heat) exchange
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Heat Exchange Element Material Specially processed nonflammable paper
Cooling capacity Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Air Filter Multidirectional fibrous fleeces
Power consumption kW 0.049 0.049 0.090 0.090 0.110 0.110 Type Sirocco fan
m3/min 7/6 7/6 8/6 11/8.5 14/11 16/12 Ultra-High 150/150 250/250 350/350 500/500 650/650 800/800 1,000/1,000 1,500/1,500 2,000/2,000
Airflow rate (H/L) Airflow Rate
cfm 247/212 247/212 282/212 388/300 494/388 565/424 High m /h 3
150/150 250/250 350/350 500/500 650/650 800/800 1,000/1,000 1,500/1,500 2,000/2,000
(50/60 Hz)
220 V 35/32 35/32 35/32 38/33 39/34 40/35 Low 100/95 155/155 230/230 320/295 500/470 700/670 860/840 1,320/1,260 1,720/1,580
Sound level (H/L) dB(A)
240 V 37/34 37/34 37/34 40/35 41/36 42/37 Fan
Ultra-High 120/154 70/96 169/222 105/150 85/125 133/170 168/192 112/150 116/140
External Static
Dimensions (H×W×D) mm 610×930×220 610×930×220 610×1,070×220 610×1,070×220 610×1,350×220 610×1,350×220
Pressure High Pa 106/131 54/65 141/145 66/52 53/67 92/85 110/86 73/72 58/32
Machine weight kg 19.0 19.0 23.0 23.0 27.0 27.0 (50/60 Hz)
Low 56/60 24/20 67/30 32/18 35/38 72/61 85/60 56/50 45/45
Note: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Motor Output kW 0.030X2 0.090X2 0.140X2 0.280X2 0.280X4
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. Connection Duct Diameter mm 100 150 200 250 350
(See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. Unit ambient condition -15°C–50°CDB, 80%RH or less
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
65 Notes: Detail spesification refer to Engineering Data Book 66
Control System Advanced Control Systems for VRV System
System structure
Individual Control Systems For VRV Systems Up to 512 groups
intelligent Touch Manager System Overview (1024 indoor units)
Navigation Remote Controller (Wired remote controller) (Option)
Air Conditioning Up to 650
This simple, modern designed remote Displays current airflow, swing, temperature, Network Service System
management points
controller with fresh white colour matches operating mode and timer settings design.
your interior design. Operation is much easier and smoother, just
Operation is much easier and smoother, follow the indications on the navigation remote
just follow the indications on the controller.
One D -NET system
navigation remote controller. * Individual airflow direction, auto airflow rate and sensing sensor Max. 64 indoor unit groups (128 indoor units)
BRC1E63 BRC1C62 control can be set only via wired remote controller BRC1E63.
Cannot be set via other remote controllers.
iTM Plus Adaptor
100Mbps Max. 64 indoor unit groups
Ethernet
• Backlight LCD of new wireless remote controller Max. 64 indoor unit groups
KRP
Signal receiver unit 928BB2S
(Installed type)
Web Access
via LAN Up to 7 Adaptors
Pressing the backlight button helps
BRC7M635F operating in dark rooms. Residential A/C
Fire alarm kWh meter WAGO I/O up to 30 nodes
(For FXF(S)Q series)
67 68
Air Conditioning Network Service System
Preventive Maintenance
The intelligent Touch Manager can be connected to Daikin’ s own Air Conditioning Network
Service System for remote monitoring and verification of operation status for VRV system. By its
ability to predict malfunctions, this service provides customers with additional peace of mind.
Enhanced convenience with link to the Air Conditioning Network Service System
The intelligent Touch Manager connects seamlessly to Daikin’s 24-hour Air Conditioning Network
Service System.
ACC centre
Personnel at the centre monitor the
Trouble occurrence of malfunctions and track their
cause via the Internet.
Advance malfunction warnings help prevent
the sudden occurrence of problems later.
Even malfunctions difficult to identify
Air Conditioning Network Service System*
can be monitored remotely.
Repair *Because of restrictions
Allows dispatching of Enable prompt repairs as in applicable areas and
service engineers without service engineers know the release times, please consult
cause of the problem a Daikin representative
a call from customers. separately for details.
beforehand.
connection between VRV Notes: 1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and
Air-Conditioning Engineers (ASHRAE).
system and your BMS. 2. LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries.
69 5070
Pioneer Of Multi-Split
In 1973, Daikin developed the first multi-split air conditioning system in Japan. With
over 45 years since this milestone, we have built an international reputation based
on quality, reliability, and advanced technology – all of which are incorporated into
our products.
Daikin’s multi-split air conditioners require only a single outdoor unit to maintain the
optimum comfort in up to five rooms. The countless benefits offered by a multi-split
system are further enhanced by Daikin’s DC inverter control and the next-generation
R-32 refrigerant.
71 72
Indoor Units WALL MOUNTED TYPE
PRODUCT LINE UP
LOW STATIC PRESSURE DUCT CTKM Cooling only
2.5 kW (1 HP) CTKM25RVM4
3.5 kW (1.5 HP) CTKM35RVM4
CTKM50RVM
Slim Duct Cooling only 5.0 kW (2 HP) CTKM60RVM
CDXP25RVM4 6.0 kW (2.5 HP)
2.5 kW (1HP)
CDXP35RVM4
3.5 kW (1.5 HP)
2.7 HP 3.2 HP
(0.5 - 3.5 HP) (0.5 - 3.8 HP)
CASSETTE
6.8 kW (1.6- 9.4 kW) 8 kW (1.6 -10.2 kW)
73 5674
DAY
MSP DUCT
OFF
WALL CASSETTE
OFF ON
1.5 HP
Better During the day, we generally spend our time in the living room or working room.
Lifestyle However, during the night, we hardly spend time in those areas. Hence, this Mul-
ti-Split system is undoubtedly perfect for individuals with this mode of lifestyle.
Always save energy: maximum capacity of 5MKM100RVMV is 13.0 kW,
Multiple kinds of indoor unit during the day, it's use only 10.5 kW so it is always save energy.
Pleasant interior
More usable space
NI G HT
MSP DUCT
ON
With only one single outdoor unit, you can 1 HP
effectively control the temperature in your
entire house, while having more usable space
for your outdoor area, such as a balcony or
terrace. SLIM DUCT SLIM DUCT
OFF OFF
Enhance your interior fitting with Daikin’s
state-of-the-art technology, more choices
are available to refine your interior for a more
elegant demeanor.
WALL
CASSETTE
ON OFF
1 HP
5MK M100RV M4
ON
75 76
2 HP
Innovative Technologies
For a Better Life 1
The Ozone Layer 4
is our nature shield against all harmful sun rays i.e. UV
radiation in the stratosphere. Indeed, human has been
the cause of ozone layer depletion for over decades.
Cooler earth
UV
3. Energy Saving
Lower electricity bill Less harmful UV radiation Reluctance DC motor - With the latest
technology, all super multi NX compressors are
equipped with reluctance DC motors that
incorporate the use of magnetic torques or
Super Multi Nx neodymium magnets with reluctance torques,
Slow down shore retreat
process
Technologies resulting in a maximum energy efficiency.
4. Better Performance
1. Smooth Airflow
100 Years global warming potential Saw edge fan blade - Experience the true
Inverter technology - The inverter PCB operates
in a similar way to the accelerator of a car, which
of different refrigerants tranquility from the advanced blade design. can gently increase or decrease power. It ensures
The additional saw-tooth edge at the rear of the that your desired temperature can be reached
blade smoothens airflow over the blade’s surface faster and can be maintained constantly without
and reduces turbulence, resulting in a peaceful any fluctuations.
Approx. 30% environment for your living space.
10,900 14,800 5. Enhance Efficiency
4,750 2. Quiet and Comfortable
1,810 2,090 Expansion valve – Daikin’s smart refrigerant
1 675 Swing compressor - Noise disturbance is no control technology presents a newly designed
longer your concern. Daikin has developed EV valve that is more powerful yet cost-saving. It
CO 2 R-32 R-22 R-410A R-11 R-12 R-23 powerful swing compressors with a enhances the inverter’s performance and controls
(HFC) (HCFC) (HFC) (CFC ) (CFC ) (HFC)
high-pressure dome and lubricant oil, enabling the refrigerant usage more effectively by up to
HFC = hydrofluorocarbons CFC = chorofluorocarbons HCFC = hydrochlorofluorocarbons the engine to run smoothly, quietly, and efficiently. 80%.
* For residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in
the japanese market.
77 78
Why Daikin inverter? SUPER P OW ERFUL
Super Multi NX: Smart, comfortable, Be worry-free when you suddenly have a guest or need an
Best Choice for Your Lifestyle 20 Inverter Powerful
immediate cool air. This ‘Super powerful mode’ boosts up the
capacity of your air conditioners for 20 minutes, ensuring that
Daikin Inverter Technology is one of the most energy-efficient solutions to heat and cool your min Operation
everyone will have a positive impression of your open-house party!
home. It gently adjusts the power to reach your desired temperature faster, while maintains the
Maximum capacity
temperature without any fluctuations. for one room operation
RA PAIR RA MULTI
With the advantage of the multi system that has a condensing
It is considerably more effective than a non-inverter system. It can save more power consump- 3.40 kW 3.93 kW unit with higher cooling capacity than single split system, its
tion, while stabilizes the room temperature at a comfortable level throughout the day and night. total capacity can be concentrated on one room, enabling the
‘Super Powerful’ function to provide an efficient and fast
cooling.
25 class 80 class
Operation 1.5HP
COMFORTABLE AT STABLE SPEED
RA pair Ra Multi
- Less energy consumption 3 units
1.5
- Quieter HP
- Stable temperture
SPACE
1 HP ARE
SAVED
NON-INVERTER Operation
- More energy consumption Same apperance, 1 HP 1.5
HP
- Noisier different performance!
- Unstable temperture
1 HP
Effectively control the 1HP
temperature in your entire house
Strong Cooling & With its advanced inverter technology, Daikin’s Multi with only one single outdoor unit.
1 HP 3.2 HP
R32 air conditioners have a cooling capacity higher 1HP
Superior Performance than the rated capacity by up to 144%. Likewise, its
of Daikin Inverter cooling capacity is also higher than that of the split
Compressor* air conditioners when compared side-by-side, due
to the larger condensing unit.
Better
Comfort** Non
inverter
5MKM100RVM4 Temp
1 Inverter
0.2
Rated capacity = 10. 0
Max capacity = 13.0
(°C)
COMPARE
ELECTRICITY USED
ON EACH SYSTEM*
4MKM80RVM4
Rated capacity = 8. 0
Max capacity = 10.2
SINGLE SPLIT
NON INVERTER SYSTEM
INVERTER SYSTEM
Time
Rated Non-inverter Inverter
capacity
0 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.09 .5 10.0 10.5 11.0 11.5 12.0 12.5 13.0
79 80
Super Clean Filter
Air conditioners that care for your health
While the filter’s micron-level fibers trap dust, the titanium apatite effectively absorbs odours
and allergens and acts as a deodoriser. This filter delivers a consistent performance for ap-
proximately three years if it is washed with water every six months.
1.Air Filter
Air filter catches dust.
Guaranteed that
Odours
& Allergens
Will be
Adsorbed
CDXP
SLIM DUCT
1 HP
to
1.5 HP
CDXM
STANDARD
DUCT
1 HP
to
3 HP
83 84
A new MSP duct has been designed to
meet the construction challenges of mod-
ern or medium-density apartments, adding
more smart functions for better comfort and
convenience. FMA
2 HP
to
3 HP
85 86
The four-way airflow distribute
air evenly in four directions with
low noise and customizable
comfort. With their discreet
design, the central location of a
cassette is barely noticeable in
sitting flat with the ceiling.
FFA
Optional
87 88
Delivered in understated confidence,
featuring whisper quiet operation,
energy efficiency and premium com-
fort levels without compromising on
style.
• Comfort mode*
89 90
Super Convenience
Bedroom : Monday to Friday
N 23°C FF -
N 23°C FF -
INTELLIGENT EYE
Flap
Auto energy saving
Super Comfort
swing
down
Features an infrared sensor that automatically controls air
conditioning operation according to human movement for better
comfort and higher energy saving. Daikin’s Intelligent Eye, which 3-D airflow
is a sensor that intelligently switches the unit to an energy-saving
mode (+ - 2°C) when the room is unoccupied for 20 minutes. Daikin’s 3D Airflow function combines
Lourvers
swing both vertical and horizontal au-
from left to to-swings to distribute air and spread
right
comforts evenly across the room.
CTKM CTKM
25 I 35 50 I 60 I 71
Intelligent eye
(Auto energy saving)
Flap
Intelligent eye
(Comfort)
swing
up
Intelligent eye
NEW!
(Comfort & Focus)
91 92
Feature checklist
Function COMFORTABLE
AIRFLOW
COMFORT
CONTROL
LIFESTYLE
CONVENIENT
HEALTH &
CLEAN
REMOTE CONTROLLER /
TIMERS
RELIABILITY
& DURABILITY
New New
Wireless
remote
Optional
Wired
Middle static remote
(Optional)
pressure duct Optional
Wireless
remote
Optional
New New
Wired
remote
(Optional)
2x2 Cassette Optional
Wireless
remote
25/35 50/60/ 25/35 Optional
71
New New
New
Wired
remote
(Optional)
25/35 50/60/ Optional
Wall 71
Outdoor 4MKM68RVM4
Night quiet mode Priority room 5MKM100RVM4 Night quiet mode Priority room
Unit
setting setting
4MKM80RVM4
93 94
Functions
Explanation
Comfortable airflow Lifestyle Convenience Remote Controller / Timers
Power-Airflow Flap 3-D Airflow* Super Powerful Operation Weekly Timer Night Set Mode
The Power-Airflow Flap regulates the outlet aper- This function combines Vertical and Horizontal Au- This function boosts cooling or heating perfor- Schedules air conditioning settings for each day Adjusts the temperature to prevent excessive cooling or
ture to an optimum shape. to-Swing to circulate a cloud of cool or warm air mance for 20 minutes when wanting to quickly or time of the day, and customizes your desired heating for a pleasant sleep.
right to the corners of even a large room. change the room temperature. temperature to match your lifestyles.
The flaps and louvers swing in turns. (4 times per day with wireless remote
Power-Airflow Dual Flaps Econo Mode 5 times per day with wired remote)
The power-airflow dual flaps can flatten out during Daikin mobile controller (optional)
Comfort Airflow Mode This mode limits the maximum running current
the cooling operation to deliver cool air to the
Prevents uncomfortable drafts from blowing and power consumption to prevent circuit break- On/Off timer automatically
corners of a room. The flaps can direct warm
directly onto the body. To prevent drafts, the flap ers from being overloaded. Switches the air conditioner on/off at night or in the
air straight down to the floor during the heating DIII Net (optional)
moves upward during cooling operation. morning.
operation. Indoor Unit On/Off Switch Connection to the centralized control system is available
the unit can be started manually for convenience. without the need for optional adaptors.
Wide-Angle Louvers Swing pattern selection 24-Hour On/Off Timer
The Wide-Angle Louvers provide wide airflow Various pattern of airflow can be customize for Sets the on/off timer 24 hours in advance to start/stop the
coverage for effective operation, no matter where your highly comfort. operation.
the indoor unit is placed in the room.
Back light remote control
95 96
Long Pipe Length
& Compact Outdoor Unit
695 mm.
Capacity class (kW)
10.0
Window 940 mm. 320 mm.
Height
of
1,000
Outdoor mm
unit or less
990 mm.
Lowline Outdoor Units
For the interior splendor, Daikin has specifically
designed all outdoor units to be less than 1,000
mm in height. Its powerful 10.0 kW outdoor unit Easy Installation
is only 990 mm in height and
can be connected to five indoor units. The 6.8 to 8.0 class out-
door units are only 695 mm
in height. This low body
allows them to be passed
through windows easily.
More Durabilty
Less short circulation
With only one outdoor unit, there will be less air short
circulation and the compressor will not become overloaded, which
consequently increases the product lifetime.
97 98
Cooling Capacity 1 PK 1.5 PK 2 PK
Indoor unit
Airflow rate : H Cooling m3/min. 9.5 10.0 12.0
Sound power : H
Cooling dBA 49 51
Product Specification: Duct Connected Type Piping connection Liquid / Gas mm ø 6.4 /ø 9.5 ø 6.4 /ø 12.7
Power supply 1 50Hz 220-240V / 60Hz 220-230V Power supply 1 50Hz 220-240V / 60Hz 220-230V
200x1100x620
Low Static Pressure Dimensions HxWxD
mm
200x700x620 Dimensions HxWxD mm
(Package dimensions) (274x906x751)
Low Static (Package dimensions) (266x1306x751)
Duct Weight (Gross) kg 21 (26) Pressure Duct Weight (Gross) kg 30 (35)
(W=700 mm)
(W=1100 mm)
Indoor unit
Indoor unit
Airflow rate : H Cooling m3/min. 8.7 Airflow rate : H Cooling m3/min 16.0
Piping connection Liquid / Gas mm ø 6.4 /ø 9.5 Piping connection Liquid / Gas mm ø 6.4 /ø 12.7 ø 6.4 /ø 15.9
99 100
M.S.P DUCT-CONNECTED 2X2 CASSETTE
Indoor unit
Airflow rate : H Cooling m3/min. 9.0 10.0 12.0 15.0
Cassette
Power supply 1 50Hz 220-240V / 60Hz 220-230V
Operation sound dBA 33/27 36/29 38/30 42/34
Cooling
External static pressure Pa 50 (50 - 150) : Changeable in 11 stages by remote controller H/L
Piping connection Liquid / Gas mm ø 6.4 /ø 12.7 ø 6.4 /ø 15.9 Weight (Gross) kg 2.7 (4.5)
Power supply 1 50Hz 220-240V / 60Hz 220-230V Power supply 1 50Hz 220-240V / 60Hz 220-230V
CTKM
Indoor unit
Airflow rate: H Cooling m3/min. 19.5
Airflow rate: H CTXM 10.4 11.3 16.9
Cooling m3
/min.
CTKM 10.7 16.9 Operation sound
11.7 Cooling dBA 48/42/36/29
H/M/L/SL
Number of port 4 4 5
Max length
m 60 / 30 70 / 30 80 / 30
(total / each room)
ø 9.5 x 1 ø 9.5 x 2
mm ø 9.5 x 2
Gas ø 12.7 x 1 ø 12.7 x 1
ø 12.7 x 2 ø 15.9 x 2 ø 15.9 x 2
Operating range ˚CDB 10 - 46
105 106
Notes: 1. Cooling capacity in 270 CDB / 190 CWB (Indoor temperature), 350 CDB (Outdoor
temperature).
2. The total ability of connected indoor units is up to 14.5 kW.
3. It is impossible to connect only one indoor unit.
4. Capacities are based on the following contions.
Corresponding refrigerant piping length : 5 m
Level difference: 0 m
107 108
How Daikin D’Mobile operation works?
Daikin D’Smarthome
A p p licatio n
1 Free
2
Adjust A C
Wifi router
(with internet connection)
3 Receiver & Easy
via your App
109 104
110
D-MOBILE With just a few clicks on an application, you
can control your favorite AC functions right Daikin Mobile Controller
from your device.
Control Your Control your air conditioner from anywhere with
Let D-Mobile application and Daikin’s your smartphone
Air Conditioner BRP072A42 wireless LAN adaptor turn your
Anywhere, Anytime smartphone or tablet into a virtual AC remote Start/stop operation
control with connection via internet (Wi-Fi or
cellular data).
START - STOP
Operation
Set operation mode
• Automatic
Automatic • Fan onl
olny y Cooling
Provide enhanced comfort and a peace of •DDry
L
A
AT
W
S HO
URE
25 ¡c
C ooling
1 3
Adjust A C 2
Receiver
Free
via y our App
Wifi router
(with internet connection)
& Easy
Download
111 112
Daikin’s Unique Double Methode Three Steps to Decompose Harmful Substance
Outside
Powerful suction
Active plasma ion flow out *MCK55 and MC55 models only.
The plasma ion technology uses plasma Mechanism of reduction Takes in dust over a wide
discharge to release ions into the air, which
combine with components of the air to form
by active plasma ions area from 3 directions.
active species with strong oxidizing power Concentration:
like OH radical. They attach to the surface of
fungi and allergens and decompose proteins
25,000 ions/cm3 *1
Note:
in the air by oxidation. *1 The number of ions per 1cm3 of air blown into the
atmosphere
Daikin’s plasma ions have been proved safe. measured near the air outlet during operation with maximum
airflow.
+
effectively with an
electrostatic HEPA filter.
Dust collection
Inside
filter
(Electrostatic
HEPA filter) Streamer decomposes by suction
Streamer, a type of plasma discharge, Mechanism of decomposition Decomposition
decomposes hazardous chemical substances. by Streamer
The decomposition power is comparable to
thermal energy of about 100,000°C.*2 Streamer emits
high-speed
Uses Daikin’s Streamer technology
to decompose harmful substances
electrons.
Diesel exhaust
Pollen Indoor air pollutants Floating Floating
House dust (cedar,etc.)
Yellow dust PM2.5 (formaldehyde, etc.)
particulates
(DEP) viruses mould
VOC-type
City exhaust gas NOx chemical Moulds
Cockroaches House dust mites Attached Attached
Pollutants that (trichloroethylene,etc.) substances (droppings) (droppings & dead mites) viruses bacteria
can be collected Pollutants that
and deodorised Dog epidermis Cat epidermis Hamster can be reduced
epidermis Pet hair Wheat flour Body odour Attached odour
by filter (dander) (dander)
(dander)
NEW
MODEL MODEL
With wireless
remote controller Withwireless
remote controller
This product is not a medical device, medical treatment device or a therapeutic good.
This product is not intended to have any therapeutic use or to be used for the diagnosis, treatment, relief or prevention of illness.
If you have a health concern or are not feeling well, please consult a health care professional.
115 116
Functions
NEW
1 Temperature and humidity sensors 12 Moist mode
Humidity is detected and shown by an easy-to-understand Automatic control maintains relatively high humidity that is gentle
indicator. to the throat and the skin.
1
Temperature and ----- ----- ----- 15 Anti-Pollen Mode
humidity sensors
4 Dust and odour sensor lamps Switching between “standard” and “low” modes to create a
Dust (PM2.5/dust) and gentle turbulence, pollen is caught before it lands on the floor.
2 ----- Dust and odours are detected and shown in 3 easy-to-understand
odour sensor lamps colours to indicate the level.
10
Titanium apatite ---- ----- ----- -----
8 Electric dust collection 19 Child proof lock
deodorising filter Dust and pollen are collected by charging them positively and using This can be used to prevent small children from mishandling the
the electrostatic dust collection filter charged negatively. air purifier.
11 Deodorising filter
12 Moist mode ----- ----- ----- 9 Pleated dust collection filter 20 Brightness adjustment
13 Econo mode Very economical, the air purifier comes standard with 5 The brightness of the indicator panel lamp can be adjusted.
replacement filters. You will not have to buy filters for 10 years
14 Auto fan mode (1 filter can be used for 2 years).
21 Auto-Restart after Power Failure
15 Anti-pollen mode The air purifier memorises the settings for mode, airflow, etc.,
10 Titanium apatite deodorising filter and automatically returns to them when power is restored after
16 Sleep mode ---- ----- ----- ----- a power failure.
Odours and allergens are thoroughly adsorbed by the titanium
apatite and then removed.
17 Turbo mode
22 Stabilizer free
18 Off timer ---- ----- ----- -----
11 Deodorising filter Stabilizer free operation protects the vital components of machine
19 Child proof lock ----- ----- Odours are caught on the deodorising filter.
from power fluctuations. With this function installing stabilizer
becomes needless (voltage range protection: 180~264V).
Models excluding MC30 model utilize streamer to decompose
20 Brightness adjustment ----- these odours and adjuvants on the filter.
If power fluctuation is beyond the limit mentioned then a stabilizer
is required.
21
Auto-restart after
power failure
22 Stabilizer free
117 118
APAKAH ITU DAIKIN PROSHOP?
5 1
YEAR
1x24
YEARS
COMPRESSOR* INSTALLATION* SUPERVISION HOURS
FAST RESPONSE*
WARRANTY WARRANTY By Daikin*
10. OPERATION MANUAL 11. DAIKIN SUPERVISI 12. DOKUMEN SERAH TERIMA
Menjelaskan kepada konsumen bagaimana Pemasangan mendapatkan supervisi langsung Dealer Proshop akan menyediakan :
*Syarat dan ketentuan berlaku
mengoperasikan AC dari Daikin • Gambar sistem AC
• Seleksi unit
• Laporan supervisi Daikin
119
120
Premium Proshop Showroom
PT CIPTA SEJAHTERA LESTARI PT JUAN TEKNIK PT MITRA WARGA PT KENZO ADIPERKASA
Jl. Rukan Artha Gading Niaga C/30 Kelapa Gading, Jakarta Utara Jl. Pluit Barat 1 No.42, Pluit, Jakarta Utara Jl. Raya Kelapa Puan blok AF 1 / 28, Gading Serpong, Tangerang Ruko Crown Green Lake blok E no 23 , Greenlake City, Cipondoh, Tangerang
Telp : 021 - 4587 0953 Telp : 021 - 6682 980, 6667 8555 Telp : 021 - 5464 805 Telp : 021 - 5433 3890, 5433 3718, 5433 3989
[email protected] [email protected] [email protected] [email protected]
PT AIRCON DUARIBU PRATAMA PT PANDILLA DESCO JAYA KENCANA MAKMUR PT ANJAYA PARAMUDYA PERKASA
Ruko Manyar Permai Blok B8 - PIK, Jakarta Utara Ruko Altira Blok H03, Blok H No 12-15, Sunter Jaya, Jakarta Utara Jl. Pos Pengumben 28B, Jakarta Barat Jl Perak Timur 198, Surabaya
Telp : 021 - 2907 3777, 2907 3999 Telp : 021 - 2188 23 80/81 Telp : 021 - 53652222, 53653982, 5868259 Telp : 031 - 329 5198
[email protected] [email protected] [email protected] [email protected]
PT STHIRA NUSANTARA PT SUMBER SURYASUKSES MANDIRI PT MITRA SOLUSI NUSANTARA PT MULTI MAKMUR SOLUSI
Jl.Pangeran Jayakarta Ruko 135, No. A6 & A7, Jakarta Pusat Jl. RS Fatmawati No.3B - Jakarta Selatan Ruko Raya Gubeng, Jl. Karimun Jawa No. 8, Surabaya Ruko Sentra Taman Gapura G-9 Gwalk Citraland, Surabaya
Telp : 021 - 6230 2345 Telp : 021 - 7581 6176 Telp : 031 - 9944 5398 Telp : 031 - 7400 102
[email protected] [email protected] [email protected] [email protected]
PT INTI GLOBAL SELARAS PT TANGGA ERA BATU PT DAVINDO ANUGERAH UNGGUL PT MECHTRON MASTEVI INDONESIA
Jl. Cipinang Jaya No.14 D-E, Cipinang Besar Utara, Jatinegara, Jakarta Timur Jl. Dr. Saharjo No.38 B, RT.4/RW.8, Ps. Manggis, Kota Jakarta Selatan, Daerah Ruko Pasar Modern Puncak Permai, Jl. Raya Darmo Permai III No. 23, Jl. T Amir Hamzah No.38 A Medan
Telp : 021 - 2286 3002 Khusus Ibukota Jakarta 12960 Sukomanunggal, kec. Sukomanunggal, Surabaya Telp : 061 - 8008 8677
[email protected] Telp : 021 - 83708494 Telp : 031 - 5961 832 [email protected]
[email protected] [email protected]
121 122
PT DAMAI LESTARI SEJAHTERA CV ARTIC
Ruko Mahkota Raya Blok B No.12, Batam Centre, Batam JL. Turi No.14 Kesiman, Bali
Telp : 08778 7433733 / 08778 7433762 / 0812 9478 7433 Telp : 0361 - 221 597
[email protected] [email protected]
Jl. Mawar Blok M-1, Perum Puri Gading Grogol Sukoharjo, Solo
Telp : 0271-623 154, 624 960
[email protected]
Jl. Moh. Yamin No.82, Solo Jl. HOS Cokroaminoto No.41, Kota Yogyakarta
Telp : 0271 - 664 541 / 656 818 Telp : 0274 - 618 428 / 618 405
[email protected] [email protected]
123