0% found this document useful (0 votes)
22 views15 pages

Hvac Interview Quastions No Ans

This document contains 90 questions related to HVAC interview questions. It provides multiple choice answers for common questions about HVAC systems, components, sizing, installation best practices, and more. The questions cover topics like available capacities for split units, factors affecting room load, applications of VRF systems, appropriate air outlet types, flexible duct sizing, fire damper requirements, and noise ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views15 pages

Hvac Interview Quastions No Ans

This document contains 90 questions related to HVAC interview questions. It provides multiple choice answers for common questions about HVAC systems, components, sizing, installation best practices, and more. The questions cover topics like available capacities for split units, factors affecting room load, applications of VRF systems, appropriate air outlet types, flexible duct sizing, fire damper requirements, and noise ratings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

‫‪90 QUASTIONS‬‬

‫‪HVAC INTERVIEW‬‬

‫ر‬
‫‪ 90‬سؤال انتفيو يف التكييف‬

‫اعداد‪:‬‬
‫م‪ /‬عزت ر‬
‫اشف‬ ‫م‪ /‬احمد رضوان‬

‫الطابعة االول ‪2023/5‬‬


‫اﻟﺴﻼم ﻋﻠ ﻢ ورﺣﻤﺔ ﷲ‬
‫ﻌﺪ اﻟﺼﻼة واﻟﺴﻼم ﻋ ا ف اﻟﺨﻠﻖ‬
‫ﻫﺎ اﻟﻤﻠﻒ ﻫﻮ ﻣﺠﺮد وﺳ ﻠﺔ ﺗﻘﺪر ﺗﺨﺘ ﺑﻴﻬﺎ ﻣﻌﻠﻮﻣﺎﺗﻚ اﻟﻌﺎﻣﺔ ﻋﻦ اﻧﻈﻤﺔ اﻟﺘﻜﻴ ﻒ‬
‫اﺟﺎ ﺎﺗﻚ ﻋ اﻻﺳﺎﻟﺔ ﻟ ﺲ ﺎﻟﻔﻬﻠﻮة ﺠﺐ ﻋﻠ ﻚ ﻣﻌﺮﻓﺔ اﻻﺟﺎ ﺔ اﻟﺼﺤ ﺤﺔ ﻋﻠﻤ ﺎ‬
‫وﺗﻜﻮن ﻣﻦ ﻣﺼﺪر ﻋﻠ ﻣﻮﺛﻮق ﻣﺜﻞ اﻻ ﻮاد او ﻛﺘﺎﻟ ج اﻟﻤﺼﻨﻌ‬
‫ﺗﻢ اﻻﻋﺪاد ﺑﻮاﺳﻄﺔ م‪ /‬اﺣﻤﺪ رﺿﻮان ‪ -‬م‪ /‬ﻋﺰت ا ف‬
‫ﺗﺤﺖ اﻣﺮك اي ﺳﺆال ﺗﻘﺪر ﺗ ﻠﻤ‬

‫اﻟﺴﻮق‬ ‫‪ 1‬ﻗﺪرة ﻟﺘﻜﻴ ﻒ ‪ HI-WALL SPLIT‬اﻟﻘﺼﻮي اﻟﻤﺘﻮﻓﺮة‬


‫‪2 TR a‬‬
‫‪3 TR b‬‬
‫‪4 TR c‬‬

‫اﻟﻬﺎب )ﻟ ﺴﺖ ﻣﻌﺮﺿﺔ ﻟﻠﺸﻤﺲ او دور اﺧ (‬ ‫ﺣﻤﻞ اﻟﻐﺮﻓﺔ‬ ‫‪ 2‬ﻣﺎ ﻳﺆﺛﺮ ﻋ‬


‫‪wall partition a‬‬
‫‪infiltration b‬‬
‫‪electric equipment c‬‬

‫‪ 3‬ﻣ ة ﻏ ﻣﻮﺟﻮدة ﻧﻈﺎم ‪VRF‬‬


‫‪ a‬ﻣﺴﺎرات ﻣﻮاﺳ ﻛﺒ ة‬
‫‪ b‬اﺣﻤﺎل ا ﻣﻦ ‪ 50‬ﻃﻦ‬
‫‪ c‬ﻣﺘﻨ ع اﻟﻘﺪرات‬

‫‪ 4‬ﻣﺨ ج اﻟﻬﻮاء اﻟﻤﻨﺎﺳﺐ ﻣﻊ ﺳﻘﻒ ﻼﻃﺎت‬


‫‪square diffuser a‬‬
‫‪linear slot b‬‬
‫‪grill c‬‬

‫وﺟﻬﺎت اﻟﻤﺒ‬ ‫‪ 5‬ﻣﺨ ج اﻟﻬﻮاء اﻟﻤﻨﺎﺳﺐ ﻟﻠ ﻛ ﺐ ﻋ‬


‫‪grill a‬‬
‫‪louver b‬‬
‫اﻟ ﺎب‬ ‫‪ 6‬ﻋﻨﺪ ﺳﺤﺐ ﻤ ﺔ ﻣﻦ اﻟﻬﻮاء ‪ cfm 500‬ﻳﺘﻢ ﺗﺮﻛ ﺐ ﻋ‬
‫‪door grill a‬‬
‫‪door louver b‬‬
‫‪under cut c‬‬

‫‪ 7‬اﻗ ﻃﻮل ﺷﺎﺋﻊ ﻳﺘﻢ ﺗﺮﻛﻴ ﻪ ﻟـ ‪ flexible duct‬ﻫﻮ‬


‫‪1 a‬ﻣ‬
‫‪ 1.5 b‬ﻣ‬
‫‪2 c‬ﻣ‬

‫‪ 8‬ﺟﻬﺎز ﺗﻜﻴ ﻒ ﻻ ﻳﺘﻢ اﺳﺘﺨﺪام ﻣﻌﻪ ﻣﺨﺎرج ﻫﻮاء‬


‫‪cassette a‬‬
‫‪fan coil unit b‬‬
‫‪counselled c‬‬

‫‪ 9‬ﻳﺘﻢ ﺗﺮﻛ ﺐ ‪ fire damper‬ﻋ ﺧﻂ اﻟﺼﺎج اذا اﺧ ق ﺟﺪار ‪fire rated‬‬


‫ﺣﺎﻟﺔ ﺎن ﻳﺘﺤﻤﻞ ﺣﺮارة ﻟﻮﻗﺖ‬
‫‪ a‬ﺳﺎﻋﺔ‬
‫‪ b‬ﺳﺎﻋﺘ‬
‫‪ c‬ﻼﻫﻤﺎ‬

‫ﻣﻔﺎﻗ ﺪ اﻟﻀﻐﻂ‬ ‫‪ 10‬اﻗﻞ ﺷ ﻞ ﻟﺨﻄﻮط اﻟﺼﺎج‬


‫‪ a‬اﻟﻤ ــﻊ‬
‫‪ b‬اﻟﻤﺴﺘﻄ ﻞ‬
‫‪ c‬اﻟﺪاﺋﺮي‬
‫‪ d‬اﻟﺒ ﻀﺎوي‬

‫اﻟﻤ ﺎ اﻻدار ﺔ‬ ‫‪ 11‬ﻣﻌﺎﻣﻞ اﻟﻀﻮﺿﺎء‬


‫‪20 a‬‬
‫‪30 b‬‬
‫‪50 c‬‬

‫‪ 12‬ﻟﺘﻮز ـ ــﻊ ﻤ ﺔ ﻣﻦ اﻟﻬﻮاء اﻟﻤ ﺎن ﻳﺘﻢ اﺳﺘﺨﺪام‬


‫‪ a‬اﻗﻞ ﻋﺪد ﻣﺘﺎح ﻣﻦ اﻟﻤﺨﺎرج‬
‫‪ b‬ا ﻋﺪد ﻣﺘﺎح ﻣﻦ اﻟﻤﺨﺎرج‬
‫‪ c‬اﻟﻌﺪد اﻟﻤﻨﺎﺳﺐ ﻻﻓﻀﻞ ﺗﻮز ـ ــﻊ‬
‫‪ 13‬ﺧﻂ ﺻﺎج ﻣﻘﺎس )‪(500x300‬‬
‫‪ a‬اﻟﻌﺮض ﻫﻮ ‪ 500‬واﻟﻌﻤﻖ ﻫﻮ ‪300‬‬
‫‪ b‬اﻟﻌﺮض ﻫﻮ ‪ 300‬واﻟﻌﻤﻖ ﻫﻮ ‪500‬‬
‫‪c‬‬
‫‪ 14‬اﻟ ﻌﺪ اﻟﺬي ﻳﺘﺤ ﻢ ﻣﻘﺎس ﺧﻂ اﻟﻔ ع ﻣﻦ ﺧﻂ ﺻﺎج رﺋ‬
‫‪ a‬ﻃﻮل ﺧﻂ اﻟﺼﺎج اﻟﺮﺋ‬
‫‪ b‬ﻋﺮض ﺧﻂ اﻟﺼﺎج اﻟﺮﺋ‬
‫‪ c‬ﻋﻤﻖ ﺧﻂ اﻟﺼﺎج اﻟﺮﺋ‬
‫‪ d‬ﺳﻤﻚ ﺧﻂ اﻟﺼﺎج اﻟﺮﺋ‬

‫ﻟﻠﺼﺎج ﺴﺘﺨﺪم ﻟﻌﺰل‬ ‫‪ 15‬اﻟﻌﺰل اﻟﺪاﺧ‬


‫‪ a‬اﻟﺼﻮت‬
‫‪ b‬اﻟﺤﺮارة‬
‫‪ c‬ﻼﻫﻤﺎ‬

‫ﻟﻠﺼﺎج ﺴﺘﺨﺪم ﻟﻌﺰل‬ ‫‪ 16‬اﻟﻌﺰل اﻟﻠﺨﺎر‬


‫‪ a‬اﻟﺼﻮت‬
‫‪ b‬اﻟﺤﺮارة‬
‫‪ c‬ﻼﻫﻤﺎ‬

‫‪ 17‬اﻟﻌﺰل اﻟﺪاﺧ ﻟﻠﺼﺎج‬


‫‪ a‬ﻜﻮن ﻄﻮل اﻟﺼﺎج ﺎﻟ ﺎﻣﻞ‬
‫‪ b‬ﻜﻮن ﺪا ﺔ اﻟﺨﻂ ﻋﻨﺪ اﻟﻤﻜﻨﺔ‬
‫‪ c‬ﻜﻮن ﻋﻨﺪ ﻣﺨﺎرج اﻟﻬﻮاء‬

‫‪ 18‬اﻟﻌﺰل اﻟﻠﺨﺎر ﻟﻠﺼﺎج‬


‫‪ a‬ﻜﻮن ﻄﻮل اﻟﺼﺎج ﺎﻟ ﺎﻣﻞ‬
‫‪ b‬ﻜﻮن ﺪا ﺔ اﻟﺨﻂ ﻋﻨﺪ اﻟﻤﻜﻨﺔ‬
‫‪ c‬ﻜﻮن ﻋﻨﺪ ﻣﺨﺎرج اﻟﻬﻮاء‬

‫‪ 19‬ا زاو ﺔ ﻣ ﻞ ﻟﻠﻤﺴﻠﻮب اﻟﻤﺮﻛﺰي‬


‫‪10 a‬‬
‫‪15 b‬‬
‫‪20 c‬‬
‫‪30 d‬‬
‫‪ 20‬ا زاو ﺔ ﻣ ﻞ ﻟﻠﻤﺴﻠﻮب اﻟﻼﻣﺮﻛﺰي اﻟﻤﺮﻛﺰي‬
‫‪10 a‬‬
‫‪15 b‬‬
‫‪20 c‬‬
‫‪30 d‬‬

‫‪ 21‬اﻟﺸﺎﺋﻊ ﻃﻮل اﻟﻤﺴﻠﻮب ﻟﻤﺨ ج اﻟﻤﺎ ﻴﻨﺔ‬


‫‪50 - 30 a‬‬
‫‪ 90 - 50 b‬ﺳﻢ‬
‫‪ 120 - 90 c‬ﺳﻢ‬

‫ﻤ ﺔ ﻫﻮاء ﻤﻜﻦ ان ﺗﻤﺮ ﻣﻦ ﺧﻼل ‪under cut‬‬ ‫‪ 22‬اﻗ‬


‫‪cfm 100 a‬‬
‫‪cfm 300 b‬‬
‫‪cfm 500 c‬‬

‫ارﺗﻔﺎع ﻣﻤﻜﻦ ﻟـ ‪) under cut‬اﻟﺸﺎﺋﻊ(‬ ‫‪ 23‬اﻗ‬


‫‪ 3‬ﺳﻢ‬ ‫‪a‬‬
‫‪ 5‬ﺳﻢ‬ ‫‪b‬‬
‫‪ 10‬ﺳﻢ‬ ‫‪c‬‬
‫‪ 15‬ﺳﻢ‬ ‫‪d‬‬

‫اﻟﺤﻤﺎﻣﺎت‬ ‫‪ 24‬ﻣﺨ ج ﻻ ﻳﺘﻢ اﺳﺘﺨﺎﻣﻪ اﻻ‬


‫‪disk valve a‬‬
‫‪round diffuser b‬‬
‫‪linear slots c‬‬
‫‪grill d‬‬

‫‪ 25‬اﻟﺸﺎﺋﻊ ﺳﻤﻚ اﻟﻌﺰل اﻟﺨﺎر )داﺧﻞ اﻟﻤﺒ (‬


‫‪ 0.5 a‬ﺑﻮﺻﺔ‬
‫‪ 1 b‬ﺑﻮﺻﺔ‬
‫‪ 1.5 c‬ﺑﻮﺻﺔ‬
‫‪ 2 d‬ﺑﻮﺻﺔ‬
‫‪ 26‬اﻟﺸﺎﺋﻊ ﺳﻤﻚ اﻟﻌﺰل اﻟﺨﺎر )ﺧﺎرج اﻟﻤﺒ (‬
‫‪ 0.5 a‬ﺑﻮﺻﺔ‬
‫‪ 1 b‬ﺑﻮﺻﺔ‬
‫‪ 1.5 c‬ﺑﻮﺻﺔ‬
‫‪ 2 d‬ﺑﻮﺻﺔ‬

‫‪ 27‬اﻗﻞ ﺳﻤﻚ ﻟﺨﻄﻮط اﻟﺼﺎج ‪) smoke‬اﻟﺸﺎﺋﻊ(‬


‫‪mm 0.5 a‬‬
‫‪mm 0.7 b‬‬
‫‪mm 1 d‬‬
‫‪mm 1.25 e‬‬

‫‪ 28‬اﻟﺴﻤﻚ اﻟﺸﺎﺋﻊ اﺳﺘﺨﺪاﻣﻪ ﻟﺨﻄﻮط اﻟﺼﺎج ﻟﻠﻤﻜﻦ اﻟﺪاﺧ‬


‫‪mm 0.5 a‬‬
‫‪mm 0.7 b‬‬
‫‪mm 1 d‬‬
‫‪mm 1.25 e‬‬

‫‪ 29‬ا ﻋﺎﻣﻠ اﻟ ﺗﺆﺛﺮ ﻣﻔﺎﻗ ﺪ اﻟﻀﻐﻂ ﻟﺨﻄﻮط اﻟﺼﺎج‬


‫‪duct total length a‬‬
‫‪number of air out let b‬‬
‫‪number of duct branches c‬‬
‫‪volume dampers d‬‬
‫‪flexible duct e‬‬

‫‪ 30‬ﻳﺘﻢ ﺣﺴﺎب ﻣﻔﺎﻗ ﺪ اﻟﻀﻐﻂ ﻟﻠﺼﺎج‬


‫‪ a‬ﻟﻠﺨﻂ اﻻﻃﻮل‬
‫‪ b‬ﻟﻠﺨﻂ اﻻﺻﻌﺐ‬
‫‪ c‬ﻟﻠﺨﻂ اﻻ ﻌﺪ‬
‫‪ 31‬ﺧﻄﻮط اﻟﺼﺎج اﻟﺬي ﻻ ﻳﺘﻢ ﻋﺰﻟﻬﻢ‬
‫‪supply air duct a‬‬
‫‪fresh air duct b‬‬
‫‪smoke air duct c‬‬
‫‪return air duct d‬‬
‫‪exhaust air duct e‬‬

‫ي(‬ ‫اﻟﻤﺨﺎزن )اﻟ ﻮد اﻟﻤ‬ ‫‪ 32‬ﻋﺪد ﻣﺮات ﺗﻐ اﻟﻬﻮاء‬


‫‪ 5 a‬ﻣﺮة‬
‫‪ 6 b‬ﻣﺮة‬
‫‪ 7 c‬ﻣﺮة‬
‫‪ 8 d‬ﻣﺮة‬

‫ﺔ اﻟﻬﻮاء ‪ fresh‬اﻟﻤﻄﻠ ﺔ ﻟﻠﻤ ﺎن‬ ‫‪ 33‬اﻟ ﻤ‬


‫اﻟ ﻮد اﻟﻤ ي‬ ‫ا‬ ‫‪a‬‬
‫ﻛﻮد ‪ashrea‬‬ ‫ا‬ ‫‪b‬‬
‫ﻼﻫﻤﺎ ﻣ ﺴﺎو ﺎن‬ ‫‪c‬‬

‫‪ 34‬ﺣﻤﺎم ﻣﺘﻮﺳﻂ اﻟﺤﺠﻢ )ﺣﻮض ‪ -‬ﻗﺎﻋﺪة ‪ -‬دش( ﺗﻄﺮد ﻣﻨﻪ ﻤ ﺔ ﻫﻮاء ﺗﻘ ﺎ‬


‫‪20 cfm a‬‬
‫‪100 cfm b‬‬
‫‪200 cfm c‬‬

‫‪ 35‬ز ﺎدة ﻋﺪد اﻟﻮﺣﺪات اﻟﺼﺤ ﺔ ‪ ---‬ﻳﺆدي ﻟ ﺎدة ﻤ ﺔ اﻟﻬﻮاء اﻟﻤﻄﺮود ﻣﻦ اﻟﺤﻤﺎم‬
‫‪ a‬اﻟﻘﻮاﻋﺪ‬
‫‪ b‬اﻻﺣﻮاض‬
‫‪ c‬اﻟﻤ ﺎول‬

‫‪ 36‬اﻟﻬﻮاء اﻟﺮاﺟﻊ ا اﻟﻤﻜﻨﺔ ﻜﻮن‬


‫‪free a‬‬
‫‪ducted b‬‬
‫‪both of them c‬‬
‫ﺣﺎﻟﺔ اﻟﻤﻜﻨﺔ ﺎﻧﺖ‬ ‫‪ 37‬ﻳﺘﻢ اﺳﺘﺨﺪام ‪ free‬ﻟﻬﻮاء اﻟﺮاﺟﻊ‬
‫ﻧﻔﺲ اﻟﻤ ﺎن اﻟﺬي ﺗﻜ ﻔﻪ‬ ‫‪a‬‬
‫‪ b‬ﺧﺎرج اﻟﻤ ﺎن اﻟﺬي ﺗﻜ ﻔﻪ‬
‫ﺣﺎﻟﻪ ﻋﺪم وﺟﻮد ﺳﻘﻒ ﻣﺴﺘﻌﺎر‬ ‫‪c‬‬
‫ﺣﺎﻟﺔ وﺟﻮد ﺳﻘﻒ ﻣﺴﺘﻌﺎر‬ ‫‪d‬‬

‫ﺣﺎﻟﺔ اﻟﻤﻜﻨﺔ ﺎﻧﺖ‬ ‫‪ 38‬ﻳﺘﻢ اﺳﺘﺨﺪام ‪ ducted‬ﻟﻬﻮاء اﻟﺮاﺟﻊ‬


‫ﻧﻔﺲ اﻟﻤ ﺎن اﻟﺬي ﺗﻜ ﻔﻪ‬ ‫‪a‬‬
‫‪ b‬ﺧﺎرج اﻟﻤ ﺎن اﻟﺬي ﺗﻜ ﻔﻪ‬
‫ﺣﺎﻟﻪ ﻋﺪم وﺟﻮد ﺳﻘﻒ ﻣﺴﺘﻌﺎر‬ ‫‪c‬‬
‫ﺣﺎﻟﺔ وﺟﻮد ﺳﻘﻒ ﻣﺴﺘﻌﺎر‬ ‫‪d‬‬

‫‪ 39‬ﻧﻈﺎم ﺗﻮز ـ ــﻊ اﻟﻬﻮاء اﻟﺸﺎﺋﻊ ﻫﻮ‬


‫‪CAV‬‬ ‫‪a‬‬
‫‪VAV‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫اﻻﺣﻤﺎل اﻟﺘ ﺪ ﺔ‬ ‫‪ 40‬اﻟﻨﻈﺎم اﻻ‬


‫‪air chiller system‬‬ ‫‪a‬‬
‫‪water chiller system b‬‬
‫‪vrf system‬‬ ‫‪c‬‬

‫ﻣ ة‬ ‫‪ 41‬وﺟﻮد اﻻﻧﻔ ﺗﺮ اﻟﺘﻜﻴ ﻒ ﻌ‬


‫ﺗﺨ ﻒ ﺳﺎﻋﺎت اﻟﻌﻤﻞ‬ ‫‪a‬‬
‫ﺗﻘﻠ ﻞ اﻟﺼ ﺎﻧﺔ‬ ‫‪b‬‬
‫ﺗﻮﻓ اﻟ ﻬ ﺎء‬ ‫‪c‬‬

‫‪ 42‬ﻞ ﻣﺎ ﻘﻞ درﺟﺔ ﺣﺮارة اﻟ ﻣﻮﺳﺘﺎت ﻟﻠﻤ ﺎن اﻟﻤﺮاد ﺗ ﺪە ‪ ،‬اﻟﺤﻤﻞ اﻟﺤﺮاري‬


‫ﻳ ﺪ‬ ‫‪a‬‬
‫ﻘﻞ‬ ‫‪b‬‬
‫ﻻ ﻳﺘﻐ‬ ‫‪c‬‬
‫‪ 1 43‬ﻃﻦ ﺗ ﺪي ﺎ ﻤ ﺔ ﻣﻦ اﻟﻬﻮاء )اﻟﺸﺎﺋﻊ(‬
‫‪1 tr = 200 cfm‬‬ ‫‪a‬‬
‫‪1 tr = 300 cfm‬‬ ‫‪b‬‬
‫‪1 tr = 400 cfm‬‬ ‫‪c‬‬
‫‪1 tr = 500 cfm‬‬ ‫‪d‬‬

‫‪ 1 44‬ﻃﻦ ﺗ ﺪي ﺎ ﻤ ﺔ ﻣ ﺎة )اﻟﺸﺎﺋﻊ(‬
‫‪1 tr = 1.2 gpm‬‬ ‫‪a‬‬
‫‪1 tr = 2 gpm‬‬ ‫‪b‬‬
‫‪1 tr = 2.4 gpm‬‬ ‫‪c‬‬
‫‪1 tr = 3 gpm‬‬ ‫‪d‬‬

‫‪ 45‬ﻟﺘﺤﻘﻴﻖ ﻇﺮوف ﺗﻜﻴ ﻒ ﻣﻌﻴﻨﻪ ﻳﺘﻢ اﺳﺘﺨﺪام‬


‫‪fan coil unit‬‬ ‫‪a‬‬
‫‪air handling unit‬‬ ‫‪b‬‬
‫‪package unit‬‬ ‫‪c‬‬
‫‪free stand unit d‬‬

‫اﻟﻤﺴﺎﺟﺪ واﻟ ﻨﺎ ﺲ‬ ‫‪ 46‬اﻟﺘﻜﻴ ﻒ اﻟﺸﺎﺋﻊ اﺳﺘﺨﺪاﻣﻪ‬


‫‪fan coil unit‬‬ ‫‪a‬‬
‫‪air handling unit‬‬ ‫‪b‬‬
‫‪package unit‬‬ ‫‪c‬‬
‫‪free stand unit d‬‬

‫‪ 47‬اﻻﺣﻤﺎل اﻟﺤﺮار ﺔ اﻟ ﺗﺘﻐ ﺑﺘﻐ اﺗﺠﺎة اﻟﻤﺒ‬


‫اﻻﺣﻤﺎل اﻟﺪاﺧﻠ ﺔ‬ ‫‪a‬‬
‫اﻻﺣﻤﺎل اﻟﺨﺎرﺟ ﺔ‬ ‫‪b‬‬

‫‪ 48‬اﻟﻄ ﻘﺔ اﻻﻓﻀﻞ ﻟﺘﺤﺪ ﺪ ﻋﺪد اﻻﺷﺨﺎص ﺎﻟﻤ ﺎن ﻣﻦ اﺟﻞ اﻟﺤﺴﺎ ﺎت اﻟﺤﺮار ﺔ‬


‫ﻧﻘﺴﻢ اﻟﻤﺴﺎﺣﺔ ﻋ ﻣﺴﺎﺣﺔ اﻟﻔﺮد وﻧﺤﺼﻞ ﻋ ﻋﺪد اﻻﺷﺨﺎص‬ ‫‪a‬‬
‫اﻟﻔﺮش اﻟﻤﻌﻤﺎري ﻟﻠﻤ ﺎن‬ ‫‪b‬‬

‫‪ 49‬اﻟﺠﺪار اﻟﻤﻌﺮض ﻟﻠﺸﻤﺲ ﻫﻮ ‪) .....‬أ( اﻟﺠﺪار اﻟﻐ ﻣﻌﺮض ﻟﻠﺸﻤﺲ ﻫﻮ ‪)....‬ب(‬


‫أ ‪ - wall‬ب ‪partition‬‬ ‫‪a‬‬
‫أ ‪ - partition‬ب ‪wall‬‬ ‫‪b‬‬
‫ﻞ ﻣﻦ ﻟﺪ ﻪ اﺣﻤﺎل ﺣﺮار ﺔ ‪sensible + latent‬‬ ‫‪ 50‬ﺣﺪد ﻣﻤﺎ‬
‫اﻻﺷﺨﺎص‬ ‫‪a‬‬
‫اﻻﺿﺎءة‬ ‫‪b‬‬
‫اﻟﺘﻬ ﺔ‬ ‫‪c‬‬
‫اﻟﻤﻌﺪات اﻟ ﻬ ﺎﺋ ﺔ‬ ‫‪d‬‬

‫‪ 1 51‬ﻃﻦ ﺗ ﺪي ﻌﺎدل ‪Btu ....‬‬


‫‪1 TR = 6000 btu‬‬ ‫‪a‬‬
‫‪1 TR = 8000 btu‬‬ ‫‪b‬‬
‫‪1 TR = 12000 btu‬‬ ‫‪c‬‬
‫‪1 TR = 16000 btu‬‬ ‫‪d‬‬

‫‪ 52‬ﻳﺘﻢ ﺳﺤﺐ اﻟﻌﻮادم ﻣﻦ اﻟﺠﺮاﺟﺎت‬


‫ﺛﻠﺚ ﻣﻦ ﺗﺤﺖ ‪ -‬ﺛﻠﺜ ﻣﻦ ﻓﻮق‬ ‫‪a‬‬
‫ﻧﺺ ﻣﻦ ﻓﻮق ‪ -‬ﻧﺺ ﻣﻦ ﺗﺤﺖ‬ ‫‪b‬‬
‫ﺛﻠﺚ ﻣﻦ ﻓﻮق ‪ -‬ﺛﻠﺜ ﻣﻦ ﺗﺤﺖ‬ ‫‪c‬‬

‫‪ 53‬ﻧ ع اﻟﻤﺮاوح اﻟ ﻻ ﺗﺤﺘﺎج ﺻﺎج‬


‫‪roof top‬‬ ‫‪a‬‬
‫‪wall mounted b‬‬
‫‪axial in line‬‬ ‫‪c‬‬

‫‪ 54‬ﻧ ع اﻟﻤﺨﺎرج اﻟ ﺴﺘﺨﺪم ﻣﻊ اﻻرﺗﻔﺎﻋﺎت اﻟ ﺒ ة‬


‫‪slot diffuser‬‬ ‫‪a‬‬
‫‪grill‬‬ ‫‪b‬‬
‫‪disk diffuser‬‬ ‫‪c‬‬
‫‪perforated diffuser d‬‬
‫‪jet diffuser‬‬ ‫‪e‬‬

‫اﻋﻤﺎل اﻟﺼﺎج‬ ‫ﻮد اﻟﻤﺘﺨﺼﺺ‬ ‫‪ 55‬اﻟ‬


‫‪smacna‬‬ ‫‪a‬‬
‫‪ashrea‬‬ ‫‪b‬‬
‫‪nfpa‬‬ ‫‪c‬‬
‫ﻣﻘﺎس اﻟﻄﻮل واﻟﻌﺮض ﻟﻠﺼﺎج ‪aspect ratio‬‬ ‫ﺴ ﺔﺑ‬ ‫‪ 56‬اﻗ‬
‫‪1:1‬‬ ‫‪a‬‬
‫‪1:2‬‬ ‫‪b‬‬
‫‪1:3‬‬ ‫‪c‬‬
‫‪1:4‬‬ ‫‪d‬‬
‫‪1:5‬‬ ‫‪e‬‬

‫‪ 57‬ﻋﻨﺪ اﺧﺬ ﻓ ع ﻟﻠﺼﺎج ﻜﻮن )‪(depth‬‬


‫ﻧﻔﺲ ﻋﻤﻖ اﻟﺨﻂ اﻟﺮﺋ‬ ‫‪a‬‬
‫ب ‪ 2‬ﺑﻮﺻﺔ‬ ‫اﺻﻐﺮ ﻣﻦ ﻋﻤﻖ اﻟﺨﻂ اﻟﺮﺋ‬ ‫‪b‬‬
‫ب ‪ 2‬ﺑﻮﺻﺔ‬ ‫ا ﻣﻦ ﻋﻤﻖ اﻟﺨﻂ اﻟﺮﺋ‬ ‫‪c‬‬

‫‪ 58‬ﻋﻨﺪ ﺗﻐ ﻣﻘﺎس ﺧﻂ اﻟﺼﺎج ﻔﻀﻞ ﺛﺒﻮت اﻟ ﻌﺪ‬


‫‪width‬‬ ‫‪a‬‬
‫‪depth‬‬ ‫‪b‬‬
‫‪length‬‬ ‫‪c‬‬

‫ﺳﻤﻚ اﻟﺼﺎج‬ ‫‪ 59‬اﻟﻤﺘﻐ اﻻﺳﺎ اﻟﺬي ﻳﺘﺤ ﻢ‬


‫ﻃﻮل اﻟﺨﻂ‬ ‫‪a‬‬
‫ﻋﺮض او ﻋﻤﻖ اﻟﺨﻂ‬ ‫‪b‬‬

‫‪ 60‬ﻠﻤﺎ زاد ‪ gauge‬ﻟﻠﺼﺎج ﻠﻤﺎ‬


‫زاد ﺳﻤﻚ اﻟﺼﺎج‬ ‫‪a‬‬
‫ﻗﻞ ﺳﻤﻚ اﻟﺼﺎج‬ ‫‪b‬‬

‫‪ 61‬ﻳﺘﻢ ﻋﻤﻞ اﻟﻤﺴﻠﻮب ﻌﺪ اﺧﺬ اﻟﻔﺮﻋﺎت ﻤﺴﺎﻓﺔ )اﻟﺸﺎﺋﻊ(‬


‫‪ 5‬ﺳﻢ‬ ‫‪a‬‬
‫‪ 10‬ﺳﻢ‬ ‫‪b‬‬
‫‪ 20‬ﺳﻢ‬ ‫‪c‬‬

‫‪ 62‬ﻳﺘﻢ ﺗﺤﺪ ﺪ ﻗﻄﺮ اﻟﺘ ﺶ ﺑﻨﺎء ﻋ‬


‫ﻋﺮض ﺧﻂ اﻟﺼﺎج‬ ‫‪a‬‬
‫ﻃﻮل ﺧﻂ اﻟﺼﺎج‬ ‫‪b‬‬
‫ي(‬ ‫‪ 63‬اﻗﻞ ﻗﻄﺮ ﻟﻠﺘ ﺶ ﻤﻜﻦ اﺳﺘﺨﺪاﻣﻬﻢ ﻣﻊ ﺧﻄﻮط اﻟﺼﺎج )ﺣﺴﺐ اﻟ ﻮد اﻟﻤ‬
‫‪ 6‬ﻣﻠﻢ‬ ‫‪a‬‬
‫‪ 8‬ﻣﻠﻢ‬ ‫‪b‬‬
‫‪ 10‬ﻣﻠﻢ‬ ‫‪c‬‬
‫‪ 12‬ﻣﻠﻢ‬ ‫‪d‬‬
‫‪ 15‬ﻣﻠﻢ‬ ‫‪e‬‬

‫ﻟﻠ ﺎﻧﻔﺎس‬ ‫‪ 64‬اﻻﺳﺘﺨﺪام اﻻﺳﺎ‬


‫ﻣﺎﻧﻊ اﻟﺼﻮت‬ ‫‪a‬‬
‫ﻣﺎﻧﻊ اﻻﻫ ازات‬ ‫‪b‬‬
‫ﻣﺎﻧﻊ ﻟﻠﺤﺮارة‬ ‫‪C‬‬

‫‪ 65‬اﻣﺎ ﻦ اﺳﺘﺨﺪام اﻟ ﺎﻧﻔﺎس‬


‫ﻋﻨﺪ ﻣﺨﺎرج اﻟﻬﻮاء‬ ‫‪a‬‬
‫ﻋﻨﺪ ﻣﺨ ج اﻟﻤﻜﻦ‬ ‫‪b‬‬

‫‪ 66‬اﺳﻬﻞ اﻟﻄﺮق ﻻﺧﺘ ﺎر ﺧﻄﻮط اﻟﺼﺎج )اﻟﺸﺎﺋﻊ(‬


‫اﻟﻀﻮء‬ ‫‪a‬‬
‫اﻟﺪﺧﺎن‬ ‫‪b‬‬
‫اﻟﻀﻐﻂ‬ ‫‪c‬‬

‫ﻧﻈﺎم اﻻ ﺸ ﻠﺮات ﻫﻮ‬ ‫‪ 67‬ﻣﺎﺋﻊ اﻟﺘ ﺪ داﺧﻞ اﻟﻤﻮاﺳ‬


‫اﻟﻔ ﻮن‬ ‫‪a‬‬
‫اﻟﻤﺎء‬ ‫‪b‬‬
‫اﻟﻬﻮاء‬ ‫‪c‬‬

‫‪ 68‬ﺤﺘﺎج ﻧﻈﺎم ‪ -----‬ﻟـ ‪cooling tower‬‬


‫‪water chiller system a‬‬
‫‪air chiller system b‬‬

‫‪ 69‬ﻧﻈﺎم اﻻ ﺸ ﻠﺮات ﻋﻨﺪ ﻓﺮق ‪ 12‬درﺟﺎت ﺣﺮارة ﻜﻮن ‪ 1‬ﻃﻦ ﺗ ﺪي‬


‫‪2.4 gpm‬‬ ‫‪a‬‬
‫‪2.2 gpm‬‬ ‫‪b‬‬
‫‪2 gpm‬‬ ‫‪c‬‬
‫‪ 70‬اﻟﻔﺎن ﻛ ﻞ ﻣﻦ اﻟﻨ ع ‪4pipe & 4way‬‬
‫ﺴﺨ ﻓﻘﻂ‬ ‫‪a‬‬
‫ﺗ ﺪ ﻓﻘﻂ‬ ‫‪b‬‬
‫ﺴﺨ وﺗ ﺪ‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 71‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب ﻟﻠﻔﺎن ﻛ ﻞ ﻣﺤ ﺲ اﻻﺗﺰان ﻳﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 72‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب ﻟﻠﻔﺎن ﻛ ﻞ ﻣﺤ ﺲ اﻟﻔﻠ ‪ strainer‬ﻳﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 73‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب ﻟﻠﻔﺎن ﻛ ﻞ ﻣﺤ ﺲ ‪ gate‬ﻳﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 74‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب ﻟﻠﻔﺎن ﻛ ﻞ ﻣﺤ ﺲ ‪ 2way or 3way‬ﻳﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 75‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب اﻻ ﺸ ﻠﺮ ﻣﺤ ﺲ ﻋﺪم اﻟﺮﺟ ع ﻳﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﺧﻂ‬ ‫‪ 76‬ﻣﺠﻤﻮﻋﺔ اﻟﻬﻮك اب ﻋﻤﻮﻣﺎ اﻟﻮﺻﻠﺔ اﻟﻤﺮﻧﺔ ﺗﺮﻛﺐ ﻋ‬


‫‪inlet‬‬ ‫‪a‬‬
‫‪outlet‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬
‫‪ 77‬اﻟﻤﺴﻠﻮب ﻗ ﻞ اﻟﻤﻀﺨﺔ ﻜﻮن ﻣﻦ اﻟﻨ ع‬
‫اﻟﻤﺮﻛﺰي‬ ‫‪a‬‬
‫اﻻﻣﺮﻛﺰي‬ ‫‪b‬‬

‫‪ 78‬اﻟﻤﺴﻠﻮب ﻌﺪ اﻟﻤﻀﺨﺔ ﻜﻮن ﻣﻦ اﻟﻨ ع‬


‫اﻟﻤﺮﻛﺰي‬ ‫‪a‬‬
‫اﻻﻣﺮﻛﺰي‬ ‫‪b‬‬

‫ﻌ‬ ‫‪ 79‬ﺗﺮﻛ ﺐ اﻟﻤﻀﺨﺎت ﻋ اﻟﺘﻮا‬


‫ﻤ ﺔ ﻣﺎﺋﻊ ﺛﺎﺑﺘﺔ و ز ﺎدة اﻟﻀﻐﻂ‬ ‫‪a‬‬
‫ز ﺎدة ﻤﺴﺔ اﻟﻤﺎﺋﻊ و ﺛﺒﻮت اﻟﻀﻐﻂ‬ ‫‪b‬‬

‫‪ 80‬ﺗﺮﻛ ﺐ اﻟﻤﻀﺨﺎت ﻋ اﻟﺘﻮازي ﻌ‬


‫ﻤ ﺔ ﻣﺎﺋﻊ ﺛﺎﺑﺘﺔ و ز ﺎدة اﻟﻀﻐﻂ‬ ‫‪a‬‬
‫ز ﺎدة ﻤ ﺔ اﻟﻤﺎﺋﻊ و ﺛﺒﻮت اﻟﻀﻐﻂ‬ ‫‪b‬‬

‫‪ 81‬اﻟﻤﻀﺨﺎت اﻟ ﻜﻮن ﻓﻴﻬﺎ اﻟﻄﺮد ﻋﻤﻮدي ﻋ اﻟﺴﺤﺐ‬


‫‪end suction pumps‬‬ ‫‪a‬‬
‫‪inline pupms‬‬ ‫‪b‬‬

‫اﻻﺳﻔﻞ ﻟﻠﺨﺰان ﻋ اﻟﺴﻄﺢ‬ ‫‪ 82‬ﻣﻀﺨﺎت دورﻫﺎ رﻓﻊ اﻟﻤ ﺎة ﻣﻦ اﻟﺨﺰان‬


‫‪booster pumps‬‬ ‫‪a‬‬
‫‪lifting pumps b‬‬
‫‪circulation pumps‬‬ ‫‪c‬‬

‫ﺿﻐﻂ اﻟﻤ ﺎة‬ ‫‪ 83‬ﻣﻀﺨﺎت دورﻫﺎ رﻓﻊ وﺗﻮز ـ ــﻊ وﺗﻌ ﺰ واﻟﺘﺤ ﻢ‬
‫‪booster pumps‬‬ ‫‪a‬‬
‫‪lifting pumps b‬‬
‫‪circulation pumps‬‬ ‫‪c‬‬
‫‪ 84‬ﻣﻀﺨﺎت دورﻫﺎ دوران اﻟﻤ ﺎة داﺧﻞ اﻟﻨﻈﺎم‬
‫‪booster pumps‬‬ ‫‪a‬‬
‫‪lifting pumps b‬‬
‫‪circulation pumps‬‬ ‫‪c‬‬

‫‪ 85‬ﺑﻨﺎء ﻋ ‪ pump curve‬اﻟﺘﺎ )ﻣﺠﺮد رﺳﻤﺔ ﻛﺮو (‬


‫ﻋﻨﺪ ‪ Q= 6000‬ﻫﺘﻜﻮن ‪…=H‬‬
‫واﻟ ﻔﺎءة = ‪...‬‬
‫و‪.... =bhp‬‬

‫ﺧﻂ‬ ‫ﻧﻈﺎم اﻻ ﺸ ﻠﺮات ﻋ‬ ‫‪ 86‬ﻳﺘﻢ ﺗﺮﻛ ﺐ ﺧﺰان اﻟﺘﻤﺪد‬


‫‪suction‬‬ ‫‪a‬‬
‫‪discharge‬‬ ‫‪b‬‬
‫‪both of them‬‬ ‫‪c‬‬

‫ﻤ ﺔ اﻟﻬﻮاء اﻟﻤﻄﺮود‬ ‫‪ 87‬ﺣﻤﺎم ﻣﺴﺎﺣﺘﻪ ‪ 5‬ﻣ ﻣ ــﻊ وارﺗﻔﺎﻋﻪ ‪ 3‬ﻣ‬


‫ﻔﺮض ﻋﺪد ﻣﺮات ﺗﻐﻴ اﻟﻬﻮاء ‪ 10‬ﻣﺮات‬
‫‪CFM 50‬‬ ‫‪a‬‬
‫‪CFM 90‬‬ ‫‪b‬‬
‫‪CFM 120‬‬ ‫‪c‬‬