General Information
Up to 31.5 MPa (4570 PSI), 1100L/min (291 U.S.GPM)
Solenoid contorolled Pilot Operated Valves ............................ Page 4
Thease valves are composed of a solenoid operated pilot valve and a pilot
operated slave valve. When a solenoid is energised the pilot valve directs the
flow to move the spool of the slave valve, thus changing the direction of flow
E
in the hydraulic circuit.
High Pressure High Flow
In these valves, the nominal size "04" can provide 300 L/min (79.3 U.S.GPM),
"06" can provide 500 L/min (132 U.S.GPM) and "10" can provide 1100 L/min
(291 U.S.GPM) in the maximum flow respectively and they can also withstand
such a high pressure as 31.5 Mpa {4570 PSI} as the maximum operating
pressure. With these features of high pressure and high flow, the valves can
make the size or configuration of the equipment compact.
X Y
P
No.1
Solenoid Controlled
Pilot Operated Directional Valves
Pilot Operated Directional Valves DIRECTIONAL
Manually Operated Directional Valves
CONTROLS
Solenoids / Mounting
Solenoids
(Only for Solenoid Controlled Pilot Operated Directional Valves)
AC Solenoids
50-60 Hz common service solenoids do not require rewiring when the applied frequency is changed.
R Type Solenoids
These are rectifier and surge absorber incorporated direct current solenoids which can be used by connecting directly
to the AC power source. They have, like other DC solenoids, such advantages that the sound in on-off operation is
quite low and the coils are hardly burnt out even if the spool is stuck at the half way of its changeover for contaminant
parti-cles etc. Moreover, they can be used almost permanently without being affected by a surge voltage from the outside.
Thus, they are the solenoids of high reliability and durability.
(S)-DSHG-04
DHG-04 ISO 4401-AD-07-4-A
DMG-04
(S)-DSHG-06
DHG-06 ISO 4401-AE-08-4-A
DMG-06
(S)-DSHG-10
DHG-10 ISO 4401-AF-10-4-A
DMG-10
No.2
Solenoid Controlled
Pilot Operated Directional Valves
Pilot Operated Directional Valves DIRECTIONAL
Manually Operated Directional Valves
CONTROLS
Hydraulic Fluids / Instructions
Hydraulic Fluids
Fluid Types
Any type of hydraulic fluid, listed in the table below can be used.
Type of Fluids Remarks
Petroleum Base Oil Use fluids equivalent to ISO VG32 or VG46.
Use phosphate ester or polyol ester fluid.When phosphate ester fluid is used, prefix
Synthetic Fluids
"F-" to the model number because the special seals (fluororubber) are required to be used.
Water Containing Fluids Use water-glycol fluids or W/O emulsion fluids.
E
Note) 1: For two types of manually operated directional valves, DMT-06, 06X and DMT-10, 10X, only petroleum base
oils and polyol ester type fluids are available.
2: For use with hydraulic fluids other than those listed above, consult your Yuken representatives in advance.
Recommended Viscosity and Oil Temperatures
Always be sure to use hydraulic fluids within the stipulated conditions shown below:
Viscosity: 15 to 400 mm2/s (77 to 1800 SSU), Temperature: -15 to +70°C (5 to 160°F)
Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise lead
to breakdowns and shorten the life of the valve. Please maintain the degree of contamination within NAS 1638-Grade
12. Use 25 μm or finer line filter.
Instructions
Mounting Posture Pilot Drain Port for Solenoid Controlled Pilot Operated
In case No-spring detent type and No-spring type valves are Directional Valve
used in the solenoid de-energised state, install the valve in Avoid connecting the valve pilot drain port to a line with
such a way that the axis L-L' becomes horizontal to get the possible surge pressure.
detent effect firmly. For the valve types other than the above, Piping end of drain should be submerged in oil.
there are no restrictions on the mounting posture.
SOL a SOL b
Shockless Type
In order to benefit from a shockless operation, it is necessary
L L'
to fill the drain line with operating oil.
Only after the tank line has been filled with operating oil, start
the operation of the valve on a regular basis.
Solenoid Energisation
In no-spring type, either solenoid of the two should be ener-
gised continuously to avoid malfunction. Operating Force for Manual Override Push Pin
For double solenoid valves do not energise both at the same Please note that as the back pressure of the drain line rises,
time as it will result in coils burning out. manually override push pin turns hard to operate (See the
graph below).
Valve Tank Port 1bf. N
Avoid connecting the valve tank port to a line with possible 30 150
surge pressure.
Operating
20 120
Force
No.3
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10 DIRECTIONAL
S-DSHG-04/06/10 CONTROLS
Sub-plate Mounting
Specifications
Specifications
1
Min 2 Max. T-Line Back Max. Change-
Max. Flow Max. Max. Pilot Pressure over Frequency Approx.
Valve Operating Required
Model Numbers L /min Pressure MPa(PSI) min-1(Cycles/Min) Mass
Type Pressure Pilot Pres.
(U.S.GPM) MPa(PSI) MPa(PSI) MPa(PSI) Ext.Drain Int.Drain AC DC R kg(1bs.)
DSHG-01-3C∗-∗-13/1380/1390 3.5 (7.7)
40 (10.6) 21 (3050) 21 (3050) 1.0 (150) 16 (2320) 16 (2320) 120 120 120
DSHG-01-2B∗-∗-13/1380/1390 2.9 (6.4)
DSHG-03-3C∗-∗-13/1390 7.2(15.9)
DSHG-03-2N∗-∗-13/1390 160 (42.3) 25 (3630) 25 (3630) 0.7 (100) 16 (2320) 16 (2320) 120 120 120 7.2(15.9)
Standard DSHG-03-2B∗-∗-13/1390 6.6(14.6)
Type (S-)DSHG-04-3C∗-∗-51/5190 8.8(19.4)
(S-)DSHG-04-2N∗-∗-51/5190 300 (79.3) 31.5 (4570) 25 (3630) 0.8 (120) 21 (3050) 16 (2320) 120 120 120 8.8(19.4)
(S-)DSHG-04-2B∗-∗-51/5190 8.2(18.1)
(S-)DSHG-06-3C∗-∗-52/5290 3
12.7 (28)
(S-)DSHG-06-2N∗-∗-52/5290 25 (3630) 0.8 (120) 120 120 120 12.7 (28)
500 (132) 31.5 (4570) 21 (3050) 16 (2320)
(S-)DSHG-06-2B∗-∗-52/5290 12.1 (27)
Shockless (S-)DSHG-06-3H∗-∗-52/5290 21 (3050) 1.0 (150) 110 110 110 13.5 (30)
Type (S-)DSHG-10-3C∗-∗-42/4290 120 120 100 45.3(100)
25 (3630)
(S-)DSHG-10-2N∗-∗-42/4290 3
100 100 100 45.3(100)
1100 (291) 31.5 (4570) 1.0 (150) 21 (3050) 16 (2320)
(S-)DSHG-10-2B∗-∗-42/4290 44.7 (99)
21 (3050) 60 60 50
(S-)DSHG-10-3H∗-∗-42/4290 53.1(117)
1. The maximum flow means the limited flow without inducing any
abnormality to the operation (changeover) of the valve. For details,
please refer to the "List of Standard Models and Maximum Flow" on
pages 9 to 13.
Yuken can offer flanged connection valves described
2. In case of internal drain type valve, the differential pressure between below. Consult Yuken for the details.
pilot pressure and back pressure at tank port should be kept more than
the minimum pilot pressure. Rated Flow Max. Pressure
Model Numbers
3. The minimum pilot pressure for the valve with pilot piston is 1.8 MPa L /min (U.S.GPM) MPa (PSI)
(260 PSI). DSHF-10-∗∗∗-∗-27∗ 315 (83)
DSHF-16-∗∗∗-∗-37∗ 500 (132)
21 (3050)
DSHF-24-∗∗∗-∗-28∗ 1200 (317)
DSHF-32-∗∗∗-∗-27∗ 2400 (634)
No.4
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10 DIRECTIONAL
S-DSHG-04/06/10
CONTROLS
Solenoid Ratings / Sub-plates
Solenoid Ratings
Coil Frequency Voltage (V) Current & Power at Rated Voltage
Valve Type Electric source
Type (Hz) Source Rating Serviceable Range Inrush (A) Holding (A) Power (W)
50 100 80 - 110 2.42 0.51
A100 100 2.14 0.37
60 90 - 120
110 2.35 0.44
50 96 - 132 2.02 0.42
A120 120
60 108 - 144 1.78 0.31
Standard AC
Type 50 200 160 - 220 1.21 0.25
E
A200 200 1.07 0.19
60 180 - 240
220 1.18 0.22
50 192 - 264 1.01 0.21
Shockless A240 240
60 216 - 288 0.89 0.15
Type
D12 12 10.8 - 13.2 2.45
DC (K Series) D24 24 21.6 - 26.4 1.23 29
D48 48 43.2 - 52.8 0.61
R100 100 90 - 110 0.33
AC → DC Rectified (R) 50/60 29
R200 200 180 - 220 0.16
Inrush current in the above table show rms values at maximum stroke.
The coil type numbers in the shaded column are handled as optional extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
Sub-plates
Japanese Standard "JIS" European Design Standard N. American Design Standard
Valve
Approx. Approx. Approx.
Model Sub-plate Thread Sub-plate Thread Sub-plate Thread
Mass Mass Mass
Numbers Model Numbers Size Model Numbers Size Model Numbers Size
kg (1bs.) kg (1bs.) kg (1bs.)
DSGM-01-30 Rc 1/8 0.8 (1.8) DSGM-01-3080 1/8 BSP.F 0.8 (1.8) DSGM-01-3090 1/8 NPT 0.8 (1.8)
DSHG-01 DSGM-01X-30 Rc 1/4 0.8 (1.8) DSGM-01X-3080 1/4 BSP.F 0.8 (1.8) DSGM-01X-3090 1/4 NPT 0.8 (1.8)
DSGM-01Y-30 Rc 3/8 0.8 (1.8) DSGM-01Y-3090 3/8 NPT 0.8 (1.8)
DSGM-03-40 Rc 3/8 3.0 (6.6) DSGM-03-2180 3/8 BSP.F 3.0 (6.6) DSGM-03-2190 3/8 NPT 3.0 (6.6)
DSGM-03X-40 Rc 1/2 3.0 (6.6) DSGM-03X-2180 1/2 BSP.F 3.0 (6.6) DSGM-03X-2190 1/2 NPT 3.0 (6.6)
DSHG-03
DSGM-03Y-40 Rc 3/4 4.7 (10.4) DSGM-03Y-2180 3/4 BSP.F 4.7 (10.4) DSGM-03Y-2190 3/4 NPT 4.7 (10.4)
DHGM-03Y-10 Rc 3/4 4.7 (10.4) DHGM-03Y-1080 3/4 BSP.F 4.7 (10.4) DHGM-03Y-1090 3/4 NPT 4.7 (10.4)
DHGM-04-20 Rc 1/2 4.4 (9.7) DHGM-04-2080 1/2 BSP.F 4.4 (9.7) DHGM-04-2090 1/2 NPT 4.4 (9.7)
DSHG-04
DHGM-04X-20 Rc 3/4 4.1 (9.0) DHGM-04X-2080 3/4 BSP.F 4.1 (9.0) DHGM-04X-2090 3/4 NPT 4.1 (9.0)
DHGM-06-50 Rc 3/4 7.4 (16.3) DHGM-06-5080 3/4 BSP.F 8.5 (18.7) DHGM-06-5090 3/4 NPT 7.4 (16.3)
DSHG-06
DHGM-06X-50 Rc 1 7.4 (16.3) DHGM-06X-5080 1 BSP.F 8.5 (18.7) DHGM-06X-5090 1 NPT 7.4 (16.3)
DHGM-10-40 Rc 1-1/4 21.5 (47.4) DHGM-10-4080 1-1/4 BSP.F 21.5 (47.4) DHGM-10-4090 1-1/4 NPT 21.5 (47.4)
DSHG-10
DHGM-10X-40 Rc 1-1/2 21.5 (47.4) DHGM-10X-4080 1-1/2 BSP.F 21.5 (47.4) DHGM-10X-4090 1-1/2 NPT 21.5 (47.4)
DSGM-03∗ is available only for Internal pilot-Internal drain type (Use DHGM-03Y for other valves).
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
No.5
Model Number Designation
No.6
F- S- DSHG -06 -2 B 2 A -C2 -E T -R2 -A100 -C -H -N -52 -∗ -L
Special No. of Special Two Models with Pilot Drain Spool Control 3 Manual Models with
Type Series Valve Valve Spool-Spring Spool Position Pilot Choke Connec- Connec- Modification
Coil Bult-in Type of Elec- Design Design
Reverse Mtg.
Seals Type Type
Override of Orifice for trical Conduit Number Standard
Number Size Position Arrangement Valve Valve tion tion (Omit if not required) Pilot Valve Pilot Line Connection of Solenoid
2, 3, 4
C: Spring 40, 5, 60
3 Centred 7, 9, 10
11, 12 AC:
01 13
A100 , A200 None:
None: B: Spring 2, 3, 4 A120 , A240 L
2 40, 7 Japanese (Omit if not required)
Stand- Offset Standard
DC:
ard 2, 3, 4 "JIS"
Type C: Spring 40, 5, 60
D12 , D24
3 None:
Centred 7, 9, 10 D48
11, 12 R2: Terminal
With Stroke AC→DC Box Type
90:
F: 03 N: No-Spring 2 Adjustment, R100 , R200 13
DSGH: 3 Both Ends None: N.
For Solenoid 2 4 American
Phos- 40 RA: Manual Design
Controlled B: Spring None: None: Override L
phate 7 With Stroke Standard (Omit if not required)
Pilot Offset C1: Pin
Ester Operated
Internal External Adjustment,
Type 2, 4, 40 With C1 Pilot Drain Port "A" End
Direction- C: Spring 60, 10, 12 Choke
Fluids al Valve, 3 3, 5, 6 1 RB: None:
Centred
Omit if not Sub-plate 7, 9, 11 With Stroke Japanese
required Mounting C2: E: T: Standard
2, 4, 40
Adjustment, 51
04 N: No-Spring A 2 With C2 External Internal Port "B" End AC: C: "JIS" &
(3, 7) 1 (Omit if not required) European
Choke Pilot Drain A100 , A200 Push
2 2 2 N: Design
None: B: Spring 2, 4, 40 A B A120 , A240 Button & L
1
(Omit if not required) Plug-in Standard (Omit if not required)
Offset (3, 7) C1C2: Lock Nut
Stand- DC: Connector
ard C: Spring 2, 4, 40 With C1 & Type 80:
Type C2 Choke R2: With Stroke Adj., D12 , D24
Centred 60, 10, 12 D48 European
06 3 3, 5, 6 1
Both Ends 52
S: H: Pressure H: Design
7, 9, 11 Omit if not RA: With Stroke Adj., AC→DC Standard
Centred required Port "A" End Refer to 5
Shock- 2 R100 , R200 N1: (Applicable
2, 4, 40 4
less N: No-Spring 1 A RB: With Stroke Adj., Plug-in only for
(3, 7) (Omit if not required)
Type Port "B" End Connector DSHG-01)
P2: With Pilot Piston,
Directional Valves
with
S-DSHG-04 / 06 / 10
10 2 2 2
42
B: Spring 2, 4, 40 A B PA: With Pilot Piston, Light N. L
Offset (3, 7) 1 (Omit if not required) Port "A" End American (Omit if not required)
DSHG-01 / 03 / 04 / 06 / 10
Note : In spool type "3", "5", "6", "60", and "7", the combination applicable between pilot system 1. Shckless type (S-DSHG) are not available for spool type marked ( ).
and drain system is as described in the table below. 2. As for the details of the valve using the neutral position and the side position (either SOL a or
SOL b side), please refer to page 14. Furthermore, the spool types other than "2", "4", "40" (3,
Pilot Connection Drain Connection Care in Application 7) are also available.
3. In spool-spring arrangement "H" (Pressure centred models), the valves with stroke adjustment
Hold back pressure in the tank line so that the (R∗) and pilot-piston (P∗) are not available.
External Drain difference between pilot pressure and drain pressure 4. N1 stands for Plug-in connector with solenoid indicator light. N1 is not available for R-type
Internal Pilot is always more than minimum required pilot solenoids.
pressure. 5. In spool-spring arrangement "H" (Pressure centred models), in case the pilot pressure is more
Internal Drain (T) Combination is not applicable
than 10 MPa (1450 PSI), please specify that the valve should have the built-in orifice to the
External Drain pilot line.
External Pilot (E) No restrictions in the combination on us
Internal Drain (T) In the table above, the symbols and numbers highlighted with shade represent the optional extras.
The valves with model number having such optional extras are handles as options, therefore please
CONTROLS
Mounting Bolt
Mouting Bolt
Model
Japanese Standard "JIS" Tightening Torque
Numbers Name N. American Design Standard Qty.
European Design Standard Nm (in. 1bs.)
1
3 MBK-01-01-30 MBK-01-01-3090 1
DSHG-01 Mtg. Bolt Kit 2 1 set 5-6 (43 - 52)
MBK-01-02-30 MBK-01-02-3090 2
DSHG-03 Soc. Hd. Cap Screw M6 × 35 Lg. 1/4-20 UNC × 1-3/4 Lg. 4 12 - 15 (104 - 130)
M6 × 45 Lg. 1/4-20 UNC × 1-3/4 Lg. 2 12 - 15 (104 - 130)
(S-)DSHG-04 Soc. Hd. Cap Screw
M10 × 50 Lg. 3/8-16 UNC × 2 Lg. 4 58 - 72 (504 - 625)
(S)-DSHG-06 Soc. Hd. Cap Screw M12 × 60 Lg. 1/2-13 UNC × 2-1/2 Lg. 6 100 - 123 (868 - 1068)
E
(S)-DSHG-10 Soc. Hd. Cap Screw M20 × 75 Lg. 3/4-10 UNC × 3 Lg. 6 473 - 585 (4106 - 5078)
Stud Bolt
"B" Thd.
Both Ends
9 9
(.35) (.35)
A
DIMENSIONS IN
MILLIMETRES (INCHES)
Nut
"B" Thd.
Model Numbers A mm (In.) "B" Thd.
8.5 Dia.
MBK-01-01-30 94 (3.70)
(.33)
M5
MBK-01-02-30 134 (5.28)
MBK-01-01-3090 94 (3.70)
No.10-24 UNC
4 MBK-01-02-3090 134 (5.28)
9
(.16)
(.35)
15
(.59)
No.7
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10 DIRECTIONAL
S-DSHG-04/06/10
CONTROLS
Options
Options
Models with Pilot Choke Adjustment Pressure Centred Models (3H∗)
When the adjustment screw is turned clockwise, The pressure centered type can be used when the
changeover speed of the main spool becomes slow. In returning of the main spool to the neutral position is
case of the spring centred valves in particular, making required to be firmily.
slow of the returning speed of the main spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with
the valves of spring centred, no-spring, offset, pressure Graphic Symbols (Ex.: External Pilot-External Drain)
centred and the valves with stroke adjustment.
(Only for 3H6, 3H60)
Graphic Symbols (Ex.: Spring Centred) A B A B
a b a b
DSHG-01,06,10 P T
Y V Y P T V X
C2 Choke X
b a
C1 Choke Models with Stroke Adjustment (R2, RA, RB)
Y When the adjustment screw is screwed in , the main
P
T
spool stroke becomes short and flow rate reduces.
Graphic Symbols (Ex.: Spring Centred)
A B
"R2" Models
DSHG-03, 04
A B
C2 Choke a b
Y P T
a b
A B
"RB" Models
A B
a b
Y P T
Models with Pilot Piston(P2, PA, PB)
The valves with a pilot piston can be used when the
high speed changeover of the main spool is required. Additional Mass of Options
However, please not that in case of spring centered
valves, there is no change in the returning speed of the Add the mass described below to the mass of standard
main spool to the neutral position even with the pilot models on page 4, if options are required.
piston.
kg (1bs.)
Graphic Symbols (Ex.: Spring Centred) Model with Pilot Models with Models with
Model Choke Adj. Pilot Piston Stroke Adj.
"P2" Models Numbers PA PA
C1, C2 C1C2 P2 P2
a
A B b
PB PB
DSHG-03 0.65(1.4) 1.3(2.9) 0.6(1.3) 0.3 (.7)
W V
Y P T
(S-)DSHG-04 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1)
(S-)DSHG-06 0.65(1.4) 1.3(2.9) 1.0(2.2) 0.5(1.1) 1.2(2.6) 06(1.3)
"PA" Models (S-)DSHG-10 0.65(1.4) 1.3(2.9) 3.6(7.9) 1.8(4.0) 3.7(8.2) 1.85(4.1)
A B
a b
V
Y P T
Options on Pilot Valve
The same options to DSG-01 series valves are available.
"PB" Models
A B
Please refer to the Catalogue No. Pub. EC-0402 for the
a b
details.
W
Y P T
No.8
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-01 CONTROLS
List of Standard Models and Maximum Flow
E
"4" DSHG-01-3C4 40 (10.6) 40 (10.6) 40 (10.6) DSHG-01-2B4 40 (10.6) 40 (10.6) 40 (10.6)
Notes ) 1. Max. flow shows value at pilot pressure more than 1 MPa (150 PSI)
2. Max. flow in the table above represents the value in the flow condition of P → A → B → T (or P → B
→ A → T) as shown in the circuit diagram right.
In case the valve is used in the condition that either A or B port is blocked, the maximum flow differs
according to a hydraulic circuit, therefore, please consult us for details. A B
a b
P T
No.9
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-03 CONTROLS
List of Standard Models and Maximum Flow
Three Positions
Spring Centred
Graphic Symbol
A B Maximum Flow
Spool Type a b L /min (U.S.GPM)
Y P T
85 (22.5) 60 (15.9)
"4" DSHG-03-3C4 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"40" DSHG-03-3C40 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"5" DSHG-03-3C5 160 (42.3)
160 (42.3) 95 (25.1)
125 (33.0)
"60" DSHG-03-3C60 160 (42.3) 160 (42.3)
160 (42.3)
85 (22.5) 60 (15.9)
"7" DSHG-03-3C7 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"9" DSHG-03-3C9 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"10" DSHG-03-3C10 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"11" DSHG-03-3C11 160 (42.3)
160 (42.3) 95 (25.1)
85 (22.5) 60 (15.9)
"12" DSHG-03-3C12 160 (42.3)
160 (42.3) 95 (25.1)
Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
a b b
Spool Type L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T
2. Max. flow in the table above represents the value in the flow
condition of P → A → B → T (or P → B → A → T) as shown
in the circuit diagram right. A B
In case the valve is used in the condition that either A or B port a b
is blocked, the maximum flow differs according to a hydraulic
P T
circuit, therefore, please consult us for details.
No.10
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-04 / S-DSHG-04 CONTROLS
List of Standard Models and Maximum Flow
Three Positions
Spring Centred
Graphic Symbol
A B Maximum Flow
Spool Type a b L /min (U.S.GPM)
Y P T
"3" DSHG-04-3C3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
E
"4"
(S-)DSHG-04-3C4 300 (79.3) 300 (79.3) 140 (37.0) 110 (29.1)
DSHG-04-3C40 300 (79.3) 300 (79.3) 200 (52.8) 145 (38.3)
"40"
(S-)DSHG-04-3C40 300 (79.3) 250 (66.1) 120 (31.7) 110 (29.1)
"5" DSHG-04-3C5 250 (66.1) 250 (66.1) 245 (64.7) 245 (64.7)
"6" DSHG-04-3C6 300 (79.3) 260 (68.7) 245 (64.7) 235 (62.1)
DSHG-04-3C60
"60" 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
(S-)DSHG-04-3C60
"7" DSHG-04-3C7 300 (79.3) 300 (79.3) 200 (52.8) 145 (38.3)
"9" DSHG-04-3C9 300 (79.3) 300 (79.3) 280 (74.0) 250 (66.1)
"11" DSHG-04-3C11 300 (79.3) 260 (68.7) 160 (42.3) 140 (37.0)
Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
a b b
Spool Type L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T
10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
"2" (S-)DSHG-04-2N2 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B2 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
"3" DSHG-04-2N3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) DSHG-04-2B3 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
"4" (S-)DSHG-04-2N4 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B4 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
"40" (S-)DSHG-04- 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) (S-)DSHG-04-2B40 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
"7" 2N40 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) DSHG-04-2B7 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3)
Notes:1. Max flow described above shown value at pilot pressure more than 0.8 MPa (120 PSI).
2. Max. flow in the table above represents the value in the flow condition of P → A → B → T (or
P → B → A → T) as shown in the circuit diagram right. A B
In case the valve is used in the condition that either A or B port is blocked, the maximum flow a b
differs according to a hydraulic circuit, therefore, please consult us for details. P T
No.11
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-06 / S-DSHG-06 CONTROLS
List of Standard Models and Maximum Flow
Three Positions
Spring Centred Pressure Centred
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
Spool Type b a b
a L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T V
10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
410 (108) 310 (81.9) 420 (111)
"2" (S-)DSHG-06-3C2 500 (132) 500 (132) (S-)DSHG-06-3H2 500 (132) 500 (132) 500 (132)
500 (132) 500 (132) 500 (132)
"3" DSHG-06-3C3 500 (132) 500 (132) 460 (122) 370 (97.8) DSHG-06-3H3 500 (132) 500 (132) 500 (132) 500 (132)
"7" DSHG-06-3C7 500 (132) 500 (132) 450 (119) 360 (95.1) DSHG-06- 500 (132) 500 (132) 500 (132) 500 (132)
Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
a b b
Spool Type L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T
10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
"2" (S-)DSHG-06-2N2 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B2 500 (132) 500 (132) 500 (132) 500 (132)
"3" DSHG-06-2N3 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B3 500 (132) 500 (132) 500 (132) 500 (132)
"4" (S-)DSHG-06-2N4 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B4 500 (132) 500 (132) 500 (132) 500 (132)
"40" (S-)DSHG-06- 500 (132) 500 (132) 500 (132) 500 (132) (S-)DSHG-06-2B40 500 (132) 500 (132) 500 (132) 500 (132)
"7" 2N40 500 (132) 500 (132) 500 (132) 500 (132) DSHG-06-2B7 500 (132) 500 (132) 500 (132) 500 (132)
Notes:1. The relation between max. flow and pilot pressure in the table above is as shown
below.
(Example) Pilot Pressure at 0.8 MPa (120 PSI).
410 (108) In case pressure centred models, pilot
Maximum flow rate is constant regardless of pilot pressure. 500 (132) pressure is more than 1 MPa (150 PSI)
Pilot Pressure more than 0.8 MPa (120 PSI). 500 (132)
In case pressure centred models, pilot pressure is more than Pilot Pressure at 1.5 MPa (220 PSI).
1 MPa (150 PSI).
2. Max. flow in the table above represents the value in the flow condition of P → A →
B → T (or P → B → A → T) as shown in the circuit diagram right. A B
In case the valve is used in the condition that either A or B port is blocked, the a b
maximum flow differs according to a hydraulic circuit, therefore, please consult us P T
for details.
No.12
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-10 / S-DSHG-10 CONTROLS
List of Standard Models and Maximum Flow
Three Positions
Spring Centred Pressure Centred
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
Spool Type b a b
a L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T V
10 MPa 16 MPa 25 MPa 31.5 MPa 10 MPa 16 MPa 25 MPa 31.5 MPa
Model Numbers Model Numbers
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
950 (251) 750 (198) 970 (256)
"2" (S-)DSHG-10-3C2 1100 (291) 1100 (291) (S-)DSHG-10-3H2 1100 (291) 1100 (291) 1100 (291)
1100 (291) 1100 (291) 1100 (291)
1050 (277)
"3" DSHG-10-3C3 1100 (291) 1100 (291) 1060 (280) 895 (236) DSHG-10-3H3 1100 (291) 1100 (291) 1100 (291)
1100 (291)
950 (251) 750 (198) 970 (256)
"4" (S-)DSHG-10-3C4 1100 (291) 1100 (291) (S-)DSHG-10-3H4 1100 (291) 1100 (291) 1100 (291)
1100 (291) 1100 (291) 1100 (291)
E
950 (251) 750 (198) 970 (256)
"40" (S-)DSHG-10-3C40 1100 (291) 1100 (291) (S-)DSHG-10- 1100 (291) 1100 (291) 1100 (291)
1100 (291) 1100 (291) 1100 (291)
1000 (264)
"5" DSHG-10-3C5 1100 (291) 1100 (291) 980 (259) 850 (225) 3H40 1100 (291) 1100 (291) 1100 (291)
1100 (291)
970 (256)
"6" DSHG-10-3C6 1050 (277) 880 (232) 700 (185) 570 (151) DSHG-10-3H5 1100 (291) 1100 (291) 1100 (291)
1100 (291)
970 (256)
"60" (S-)DSHG-10-3C60 1050 (277) 940 (248) 785 (207) 680 (180) (S-)DSHG-10-3H6 1100 (291) 1100 (291) 1100 (291)
1100 (291)
1040 (275) 870 (230)
"7" DSHG-10-3C7 1100 (291) 1100 (291) DSHG-10- 1100 (291) 1100 (291) 1100 (291) 1100 (291)
1100 (291) 1100 (291)
"9" DSHG-10-3C9 1100 (291) 1100 (291) 1040 (275) 870 (230) 3H60 1100 (291) 1100 (291) 1100 (291) 1100 (291)
Two Positions
No-Spring Spring Offset
Graphic Symbol Graphic Symbol
A B Maximum Flow A B Maximum Flow
a b b
Spool Type L /min (U.S.GPM) L /min (U.S.GPM)
Y P T Y P T
Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) (1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI)
"2" (S-)DSHG-10-2N2 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B2 1100 (291) 1100 (291) 1100 (291) 1100 (291)
"3" DSHG-10-2N3 1100 (291) 1100 (291) 1100 (291) 1100 (291) DSHG-10-2B3 1100 (291) 1100 (291) 1100 (291) 1100 (291)
"4" (S-)DSHG-10-2N4 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B4 1100 (291) 1100 (291) 1100 (291) 1100 (291)
"40" (S-)DSHG-10- 1100 (291) 1100 (291) 1100 (291) 1100 (291) (S-)DSHG-10-2B40 1100 (291) 1100 (291) 1100 (291) 1100 (291)
"7" 2N40 1100 (291) 1100 (291) 1100 (291) 1100 (291) DSHG-10-2B7 1100 (291) 1100 (291) 1100 (291) 1100 (291)
Notes ) 1. The relation between max. flow and pilot pressure in the table above
is as shown below.
(Example) Pilot Pressure at 1 MPa (150 PSI).
1040 (275)
Maximum flow rate is constant regardless of pilot pressure. 1100 (291)
Pilot Pressure more than 1 MPa (150 PSI). 1100 (291)
Pilot Pressure at 1.5 MPa (220 PSI).
2. Max. flow in the table above represents the value in the flow condition
of P → A → B → T (or P → B → A → T) as shown in the circuit
diagram right. A B
In case the valve is used in the condition that either A or B port is a b
blocked, the maximum flow differs according to a hydraulic circuit, P T
therefore, please consult us for details.
No.13
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01 / 03 / 04 / 06 / 10 DIRECTIONAL
CONTROLS
S-DSHG-04 / 06 / 10
Reverse Mtg. of Sol. / Special 2-Position Valve
Reverse Mounting of Solenoid.
In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b
position (side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in
the reverse position - SOL a side - is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B∗A and 2B∗B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.
A B SOL b
A B SOL a
b a
P T P T Y
Y
Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B∗A) and another
is the valve using the neutral position and SOL b position (2B∗B).
(Example) In case of Spool Type "2"
Neutral Position
SOL. a Energised SOL. b Energised
Position Position
A B
a b
Y P T
2B2A 2B2B
A B A B
b b
Y P T Y P T
Graphic
Graphic Symbols Graphic Symbols
Symbols
Model Numbers Model Numbers Model Numbers
Standard Reverse Standard Reverse Standard
Mtg. Mtg. Type Mtg. Mtg. Type Mtg.
04 A B A B 04 A B A B 04 A B
DSHG-06-2B∗A b a
DSHG-06-2B∗B b a
DSHG-06-2N∗A a b
Y P T P T Y Y P T P T Y Y P T
10 10 10
(S-)DSHG-∗-2B2A (S-)DSHG-∗-2B2B (S-)DSHG-∗-2N2A
No.14
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04 DIRECTIONAL
S-DSHG-04
CONTROLS
Preessure Drop
Pressure drop curves based on viscosity of 35 mm2/s (164 SSU) and specific gravity of 0.850.
DSHG-01
DSHG-01
PSI MPa 1 Pressure Drop Pressure Drop
200 1.4 Spool Spool
Curve Numbers Curve Numbers
Type Type
P
160
1.2 2 P → A B→ T P → B A→ T P → T P → A B→ T P → B A→ T P → T
Pressure Drop
1.0 2
3 3 2 3 2 7 3 2 3 2
120 0.8
4 3 4 2 4 2 2 9 4 2 4 2
80 0.6 4 3 2 3 2 10 3 2 3 2
0.4
E
40 3 2 3 2 11 3 2 3 2
40 0.2 5 3 2 3 2 1 12 3 2 3 2
0 0
0 10 20 30 40 L /min 60 3 2 3 2 1
0 2 4 6 8 10 U.S.GPM
Flow Rate
DSHG-03 DSHG-03
250
1.6 5
Pressure Drop
200
2 3 3 4 4 7 3 3 4 4
6
1.2 3 5 5 5 6 4 9 6 3 6 4
150
0.8 4 3 5 4 6 10 3 5 4 4
100
40 3 3 4 4 11 6 3 4 4
50 0.4
5 6 3 4 6 2 12 3 3 4 6
0
0 60 3 3 4 4 1
0 40 80 120 160 L /min
0 10 20 30 40 U.S.GPM
Flow Rate
DSHG-04, S-DSHG-04 DSHG-04
2 3 Pressure Drop Pressure Drop
PSI MPa 1 Spool Spool
180 4 Curve Numbers Curve Numbers
1.2 Type Type
160 P → A B→ T P → B A→ T P → T P → A B→ T P → B A→ T P → T
P
5
6
2 5 4 5 6 60 7 5 7 7 2
Pressure Drop
120 0.8
7
3 5 3 5 5 7 7 5 4 5 6
80 4 5 3 5 5 9 5 4 5 6
0.4 40 5 4 5 6 10 5 2 5 6
40 5 7 4 5 5 5 11 6 4 5 6
0 6 5 3 5 6 1 12 5 4 5 5
0
0 50 100 150 200 250 300 L /min
0 20 40 60 80 U.S.GPM
Flow Rate
S-DSHG-04
Pressure Drop Pressure Drop
Spool Spool
Curve Numbers Curve Numbers
Type Type
P → A B→ T P → B A→ T P → T P → A B→ T P → B A→ T P → T
2 2 2 2 4 60 6 4 6 7 2
4 2 3 2 5 10 2 2 2 4
40 2 4 2 6 12 2 2 2 5
No.15
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-06, 10 / S-DSHG-06, 10 CONTROLS
Pressure Drop
DSHG-06, S-DSHG-06
DSHG-06
1
PSI MPa 2 Pressure Drop Pressure Drop
300 2.0 Spool Spool
3 Curve Numbers Curve Numbers
Type Type
P
250 4 P → A B→ T P → B A→ T P → T P → A B→ T P → B A→ T P → T
1.6
Pressure Drop
200 5 2 8 5 8 7 60 6 5 6 7 1
1.2 3 6 4 6 7 4 7 6 4 6 7
150 6
0.8 7 4 8 5 8 7 9 6 5 6 7
100
40 8 5 8 7 10 8 5 8 7
0.4 8
50
5 8 4 5 7 1 11 8 4 5 7
0
0 6 5 3 5 4 1 12 8 5 8 7
0 100 200 300 400 500 L /min
DSHG-10, S-DSHG-10
DSHG-10
1 2
PSI MPa Pressure Drop Pressure Drop
300 2.0 3 Spool Spool
Curve Numbers Curve Numbers
Type Type
P
4
250
1.6
P → A B→ T P → B A→ T P → T P → A B→ T P → B A→ T P → T
5
Pressure Drop
200 2 9 6 9 8 60 8 5 8 5 3
1.2 6 3 7 6 7 7 5 7 7 6 7 7
150
7 4 9 6 9 6 9 7 6 7 8
0.8
100 8 40 9 6 9 8 10 9 5 9 8
50 0.4 9 5 9 6 8 6 1 11 9 6 8 7
0
0 6 5 3 5 2 2 12 9 7 9 6
0 200 400 600 800 1000 1100 L /min
For any other viscosity, multiply the factors in the table below.
mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity
SSU 77 98 141 186 232 278 324 371 417 464
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula right.
P' = P(G'/0.850)
No.16
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-04/06/10 CONTROLS
Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
Test Conditions
Coil Type : D∗(Models with DC solenoids)
Voltage : Rated Voltage
Oil Viscosity : 35 mm2/s (164 SSU)
DSHG-04 DSHG-10
E
ms ms
250
150
3C∗
Changeover Time
SOL"ON"
SOL"OFF" 200
100
2B∗ 3C∗
2N∗
Changeover Time
SOL"ON" SOL"OFF"
SOL"OFF" 150
50 SOL"ON"
2B∗
2N∗ SOL"ON","OFF"
0 100
0 5 10 15 20 25 MPa
50
0 1000 2000 3000 PSI
3600
Pilot Pressure 0
0 5 10 15 20 25 MPa
DSHG-06
0 1000 2000 3000 PSI
ms 3600
Pilot Pressure
150 3C∗
SOL"ON"
Changeover Time
SOL"OFF"
100
2B∗
2N∗ SOL"ON"
SOL"OFF"
50
0
0 5 10 15 20 25 MPa
No.17
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-01 CONTROLS
Installation Drawing
Terminal Box type: DSHG-01-∗∗∗-∗-13/1390 Mounting surface: ISO 4401-AB-03-4-A
Internal Pilot - Internal Drain Pressure Port "P" External Pilot - External Drain
Cylinder Port "B" External Pilot - Internal Drain
Space Needed to Remove AC :191.4 (7.54) Cylinder Port "A"
Solenoid-Each End DC,R :210 (8.27)
Internal Pilot - External Drain
AC :45.5 (1.79)
DC,R :55 (2.17) 40.5
(1.59)
(1.22) (.03)
31 0.75
AC : 74.2 (2.92)
DC,R : 83.5 (3.29)
(1.28)
32.5
Pilot Drain Port "Y"
"D" Thd.
170.3
(6.70)
(3.54) (.02)
(5.98)
152
(4.65)
118
(4.13)
105
(2.36)
60
(5.13)
130.3
SOL b SOL a
(4.41)
112
(3.07)
(2.56)
78
65
48 43.5
(1.71) Mounting Surface
(1.89) (O-Rings Furnished) For other dimensions, refer to "Internal Pilot Internal
125 Drain".
(4.92)
AC :158.2 (6.23)
DC,R :167.5 (6.59)
(.30)
8.5
7.5
(.59)
(.03)
0.75
(.61)
15.5
P
(1.02)
(2.48)
(1.89)
(1.22)
A B
25.8
(1.25)
31.75
(.20)
63
5.2
(1.46)
48
31
37
(.94)
T
24
(.43)
11
12.5
71 7 7 (.28) Dia. Through (.49)
(2.80) (.28) 11 (.43) Dia. Spotface 35.5
85 2 Places (1.40)
(3.35) 58.5
(2.30)
Sub-plate Piping Size "E"
"D" Thd.
Model Numbers "C" Thd. mm (IN.)
DSGM-01-30 Rc 1/8
M5 10 (.39)
DSGM-01-3080 1/8 BSP.F
DSGM-01-3090 1/8 NPT No. 10-24 UNC 12 (.47)
DSGM-01X-30 Rc 1/4
M5 10 (.39)
DSGM-01X-3080 1/4 BSP.F
DSGM-01X-3090 1/4 NPT No. 10-24 UNC 12 (.47)
DSGM-01Y-30 Rc 3/8 M5 10 (.39)
DSGM-01Y-3090 3/8 NPT No. 10-24 UNC 12 (.47)
No.18
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-01 CONTROLS
Installation Drawing
Mounting surface: ISO 4401-AB-03-4-A
Cable Departure
The position of the Plug-in connector can be changed as Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
illustrated below by loosening the lock nut. After Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)
completion of the change, be sure to tighten the lock nut
with the torque as specified below. H
E
27 70
E
F
(1.06) (2.76)
D
SOL b SOL a
C
(3.07)
78
(2.56)
65
48 43.5
(1.89) (1.71)
Lock Nut
Tightening Torque: 125
10.3 - 11.3 Nm (91-100 IN.lbs.) (4.92)
K
SOL b SOL a
L
(4.65)
(4.13)
105
DSHG-01-∗∗∗-∗-N∗-13 Rc 1/4
(2.36)
60
Dimensions mm (Inches)
Model Numbers
C D E F H J K L
DSHG-01-∗∗∗-∗-A∗-N/N1 130 (5.12) 53 (2.09) 27.5 (1.08) 39 (1.54) 74.2 (2.92) 191.4 (7.54) 158.2 (6.23) 170 (6.69)
DSHG-01-∗∗∗-∗-D∗-N/N1 141 (5.55) 64 (2.52) 27.5 (1.08) 39 (1.54) 181 (7.13)
83.5 (3.29) 210 (8.27) 167.5 (6.59)
DSHG-01-∗∗∗-∗-R∗-N 144 (5.67) 57.2 (2.25) 34 (1.34) 53 (2.09) 184 (7.24)
No.19
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-03 CONTROLS
Installation Drawing
Terminal Box Type: DSHG-03-∗∗∗-∗-13/1390 Mounting surface: ISO 4401-AC-05-4-A
Cylinder Port "B"
7(.28) Dia. Through, 11(.43) Dia. Spotface 4 Places
(The pilot and drain ports in accordance
Pressure Port "P" with the ISO original draft)
AC :191.4 (7.54) AC :45.5 (1.79)
DC,R :210 (8.27) DC,R :55 (2.17)
Solenoid Space Needed to Remove
Indicator Light 54 Solenoid-Each End
Cylinder Port "A" (2.13)
AC :67.7 (2.67)
DC,R :77 (3.03)
Model Numbers "C" Thd.
(1.81)
DSHG-03-∗∗∗-∗-13
46
G 1/2
DSHG-03-∗∗∗-∗-1390 1/2 NPT
Pilot Drain Port "Y"
Pilot Pressure Port "X" Tank Port "T" (For External Drain Models Only)
(For External Pilot Models Only)
0.5 90
(.02) (3.54)
1 44 Electrical Conduit Connection Manual Actuator
(.04) (1.73) "C" Thd. (Both Ends) 6(.24) Dia.
Double Solenoid
Models Only
SOL a SOL b
(6.90)
175.3
(6.18)
157
(4.33)
110
problem.
27
Mounting Surface 58 70
(2.28) (2.76)
(O-Rings Furnished)
170
(6.69)
AC :179.7 (7.07)
DC,R :189 (7.44) DIMENSIONS IN
N -13/1390 MILLIMETRES (INCHES)
Plug-in Connector Type: DSHG-03-∗∗∗-∗-N1
Cable Departure
J Cable Applicable:
Outside Dia. ⋅⋅⋅⋅⋅⋅ 8-10mm(.31-.39 IN.)
97 K Conductor Area ⋅⋅⋅⋅⋅⋅Not Exceeding 1.5mm2(.002 Sq. IN.)
(3.82)
C F
D
SOL a SOL b
E
(4.33)
110
58 70 19.
(2.28) (2.76)
170
(6.69)
H
Dimensions mm (Inches)
Model Numbers
C D E F H J K
DSHG-03-∗∗∗-∗-A∗-N/N1 39 (1.54) 53 (2.09) 175 (6.89) 27.5 (1.08) 179.7 (7.07) 191.4 (7.54) 47.2 (1.86)
DSHG-03-∗∗∗-∗-D∗-N/N1 39 (1.54) 64 (2.52) 186 (7.32) 27.5 (1.08)
189 (7.44) 210 (8.27) 56.5 (2.22)
DSHG-03-∗∗∗-∗-R∗-N 53 (2.09) 57.2 (2.25) 189 (7.44) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".
No.20
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-04 / S-DSHG-04 CONTROLS
Installation Drawing
Mounting surface:
Terminal Box Type: (S-)DSHG-04-∗∗∗-∗-51/5190 ISO 4401-AD-07-4-A
Pressure Port "P"
Tank Port "T" Pilot Pressure Port "X"
(For External Pilot Models Only)
204(8.03)
11(.43) Dia. Through 101.6 50.4
17.5(.69) Dia. Spotface (4.00) (1.98)
34
4 Places (1.34)
Model Numbers "C" Thd.
(S-)DSHG-04-∗∗∗-∗-51 G 1/2
(2.75)
(2.87)
(3.58)
69.8
72.9
(S-)DSHG-04-∗∗∗-∗-5190
91
1/2 NPT
(1.37)
34.9
(.06) E
50
1.5
(1.97)
Cylinder Port "A" Pilot Drain Port "Y"
(For External Drain Models Only)
7(.28) Dia. Through Cylinder Port "B"
11(.43) Dia. Spotface Solenoid Indicator Light
2 Places
Electrical Conduit Connection
AC : 191.4 (7.54) AC : 45.5 (1.79) Space Needed to Remove "C" Thd. (Both Ends)
DC,R : 210 (8.27) DC,R : 55 (2.17) Solenoid-Each End
0.5 AC : 50.7 (2.00) 48
90
(.02) (3.54) (1.89)
DC,R : 60 (2.36)
Double Solenoid Manual Actuator
Models Only 6(.24) Dia.
SOL a SOL b
(6.42)
(7.14)
181.3
163
L L'
(1.38)
(1.34)
35
34
(O-Rings Furnished)
DIMENSIONS IN
MILLIMETRES (INCHES)
Plug-in Connector Type: (S-)DSHG-04-∗∗∗-∗- N -51/5190
N1
Cable Departure
Cable Applicable:
H Outside Dia. . . . . . . 8-10 mm(.31 - .39 IN.)
0.5 Conductor Area . . . Not Exceeding 1.5 mm2 (.002 Sq. IN.)
J
(.02)
C F
D
Position of cable
SOL a SOL b
departure can be
A P B changed. For details,
E
refer to DSHG-01
(4.57)
(1.38)
(1.34)
35
34
Dimensions mm (Inches)
Model Numbers
C D E F H J K
(S-)DSHG-04-∗∗∗-A∗-N/N1 39 (1.54) 53 (2.09) 181 (7.13) 27.5 (1.08) 191.4 (7.54) 47.2 (1.86) 44.1 (1.74)
(S-)DSHG-04-∗∗∗-D∗-N/N1 39 (1.54) 64 (2.52) 192 (7.56) 27.5 (1.08)
210 (8.27) 56.5 (2.22) 53.4 (2.10)
(S-)DSHG-04-∗∗∗-R∗-N 53 (2.09) 57.2 (2.25) 195 (7.68) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".
No.21
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-06 / S-DSHG-06 CONTROLS
Installation Drawing
Mounting surface:
Terminal Box Type: (S-)DSHG-06-∗∗∗-∗-52/5290 ISO 4401-AE-08-4-A
Solenoid Indicator Light Pressure Port "P"
255(10.04)
50.5 130.2 Pilot Drain Port "Y"
(1.99) (5.13) (For External Drain Models Only)
13.5(.53) Dia. Through 53.2
20(.79) Dia. Spotface (2.09)
6 Places T P Y
(3.63)
(4.65)
92.1
118
(S-)DSHG-06-∗∗∗-∗-52 G 1/2
(1.81)
46.1
(S-)DSHG-06-∗∗∗-∗-5290 1/2 NPT
Tank Port "T"
X A B
77
(.51)
13
Pilot Pressure Port "X" (3.03)
(For External Pilot Models Only) 156
(6.14) Cylinder Port "B"
Cylinder Port "A"
Space Needed to Remove
Solenoid-Each End
AC : 191.4 (7.54) AC : 45.5 (1.79)
DC,R : 210 (8.27) DC,R : 55 (2.17)
0.5 90 AC : 50.7 (2.00) 48
(.02) (3.54) DC,R : 60 (2.36) (1.89)
Electrical Conduit Connection
"C" Thd. (Both Ends)
Manual Actuator
6(.24) Dia.
SOL a SOL b
A P B
(7.96)
202.3
(7.24)
184
L L'
(1.61)
41
AC : 45.5 (1.79)
(.24)
(O-Rings Furnished)
DIMENSIONS IN
MILLIMETRES (INCHES)
Plug-in Connector Type: (S-)DSHG-06-∗∗∗-∗- N -52/5290
N1
Cable Departure
Cable Applicable:
H Outside Dia. . . . . . . 8-10 mm(.31 - .39 IN.)
Conductor Area . . . Not Exceeding 1.5 mm2 (.002 Sq. IN.)
J
97 C F
(3.82)
D
SOL a SOL b
A P B
E
(5.39)
137
(1.61)
41
Position of cable departure can be changed. For details, refer to DSHG-01 valve on page 19.
Dimensions mm (Inches)
Model Numbers
C D E F H J K
(S-)DSHG-06-∗∗∗-A∗-N/N1 39 (1.54) 53 (2.09) 202 (7.95) 27.5 (1.08) 191.4 (7.54) 47.2 (1.86) 42.7 (1.68)
(S-)DSHG-06-∗∗∗-D∗-N/N1 39 (1.54) 64 (2.52) 213 (8.39) 27.5 (1.08)
210 (8.27) 56.5 (2.22) 52 (2.05)
(S-)DSHG-06-∗∗∗-R∗-N 53 (2.09) 57.2 (2.25) 216 (8.50) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".
No.22
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-10 / S-DSHG-10 CONTROLS
Installation Drawing
Mounting surface:
Terminal Box Type: (S-)DSHG-10-∗∗∗-∗-42/4290 ISO 4401-AF-10-4-A
Tank Port "T" Pressure Port "P"
384(15.12)
77.5 190.5
(3.05) (7.50) Pilot Drain Port "Y"
76.2 (For External Drain Models Only)
21.5(.85) Dia. Through (3.00)
32(1.26) Dia. Spotface
6 Places
Model Numbers "C" Thd.
(S-)DSHG-10-∗∗∗-∗-42
43(1.69)
G 1/2
(7.80)
(6.25)
158.8
198
L'
L (S-)DSHG-10-∗∗∗-∗-4290 1/2 NPT
(3.13)
79.4
E
21.8 114.3 78
(.77)
19.6
(.86) (4.50) (3.07)
Pilot Pressure Port "X" 233.8(9.20) Cylinder Port "B"
(For External Pilot Models Only) Solenoid Indicator Light
Space Needed to Remove
Solenoid-Each End
Cylinder Port "A" AC : 191.4 (7.54) AC : 45.5 (1.79)
DC,R : 210 (8.27) DC,R : 55 (2.17)
AC : 50.7 (2.00) 48
0.5 90 Electrical Conduit Connection
(.02) (3.54) DC,R : 60 (2.36) (1.89)
"C" Thd. (Both Ends)
Manual Actuator
Two Eye Bolts M8 6(.24) Dia.
SOL a SOL b
A P B
(10.44)
(9.72)
265.3
247
(1.75)
(1.81)
44.5
46
DIMENSIONS IN
MILLIMETRES (INCHES)
Plug-in Connector Type: (S-)DSHG-10-∗∗∗-∗- N -42/4290
N1
Cable Departure
H Cable Applicable:
J Outside Dia. . . . . . . 8-10 mm(.31 - .39 IN.)
Conductor Area . . . Not Exceeding 1.5 mm2 (.002 Sq. IN.)
97 C
(3.82) F
Position of cable
departure can be
D
(1.81)
(1.77)
46
45
Dimensions mm (Inches)
Model Numbers
C D E F H J K
(S-)DSHG-10-∗∗∗-A∗-N/N1 39 (1.54) 53 (2.09) 265 (10.43) 27.5 (1.08) 191.4 (7.54) 47.2 (1.86) 19.7 (.78)
(S-)DSHG-10-∗∗∗-D∗-N/N1 39 (1.54) 64 (2.52) 276 (10.87) 27.5 (1.08)
210 (8.27) 56.5 (2.22) 29 (1.14)
(S-)DSHG-10-∗∗∗-R∗-N 53 (2.09) 57.2 (2.25) 279 (10.98) 34 (1.34)
For other dimensions, refer to "Terminal Box Type".
No.23
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-03, 04, 06, 10 / S-DSHG-04, 06, 10 CONTROLS
Options
DSHG-03-∗∗∗-C1/C2/C1C2 DSHG-03-∗∗∗-C1/C2/C1C2-N
N1
Fully Fully
37.5 Extended 37.5 Extended
(1.48) 59 (2.32) (1.48) 59 (2.32)
3 3
1 1
SOL a SOL b
SOL a SOL b
2 2
C
J
D
E
E
F
F
H
H
(S-)DSHG-04-∗∗∗-C1/C2/C1C2 (S-)DSHG-04-∗∗∗-C1/C2/C1C2-N
N1
Fully Extended Fully Extended
59 59
(2.32) (2.32) 3
3
1
1
SOL a SOL b 2
SOL a SOL b
2
J
C
D
E
E
F
F
H
H
10-∗∗∗ 10-∗∗∗
(S-)DSHG-06 -C1/C2/C1C2 (S-)DSHG-06 -C1/C2/C1C2-N
N1
Fully Extended Fully Extended
59 (2.32) 59 (2.32)
3 3
1 1
SOL a SOL b
SOL a
A P B
SOL b
2 A P B
2
J
C
D
E
E
F
F
H
H
No.24
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-03, 04, 06, 10 / S-DSHG-04, 06, 10 CONTROLS
Options
(1.38)
35
Stroke Adj. Screw (Port "A" End) 99 (3.90) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex. 13 (.51) Hex.
E
Fully Extended
(S-)DSHG-04-∗∗∗-R∗
Fully Extended
289 (11.38)
SOL a SOL b
Lock Nut 17(.67) Hex.
(1.30)
33
Stroke Adj. Screw (Port "A" End) 93 (3.66) Stroke Adj. Screw (Port "B" End)
13 (.51) Hex. Fully Extended 13 (.51) Hex.
10-∗∗∗ ∗
(S-)DSHG-06 -R
Fully Extended
C
SOL a SOL b
A P B
Lock Nut 24(.94) Hex.
E
Stroke Adj. Screw (Port "A" End) Stroke Adj. Screw (Port "B" End)
D
17 (.67) Hex. 17 (.67) Hex.
Fully Extended
Model Numbers C D E
(S-)DSHG-06-∗∗∗-R2 376 (14.80) 111 (4.37) 40 (1.57)
(S-)DSHG-10-∗∗∗-R2 558 (21.97) 164.5 (6.48) 65 (2.56)
DIMENSIONS IN
MILLIMETRES (INCHES)
D D
No.25
Sub-plate for
Solenoid Controlled Pilot Operated DIRECTIONAL
Directional Valves CONTROLS
Installation Drawing
DHGM-03Y-10/1080/1090 Sub-plate F
120 "C" Thd. "D" Thd. "E" Thd.
(4.72) Model Numbers mm (in.)
15 90 DHGM-03Y-10 Rc 3/4 Rc 1/4
(.59) (3.54) M6 13(.51)
18 62 DHGM-03Y-1080 3/4 BSP.F 1/4 BSP.F
(.71) (2.44)
DHGM-03Y-1090 3/4 NPT 1/4 NPT 1/4-20 UNC 15(.59)
54
(2.13)
37.3(1.47) 50
11(.43) Dia. (1.97)
"D" Thd. 4 Places
Used only on external 27(1.06) 43(1.69) 80
pilot type valves. (3.15)
To be plugged on internal
16.7(.66) 42(1.65) 45
pilot type valves.
25 (1.77)
(.98) 8(.31) 3.2 25(.98) 10
22(.87)
16(.63)
(.39)
21.5(.85)
(.13) (.39)
10
32.5(1.28)
6.4(.25)
(.47)
12
P
(1.85)
47
(2.99)
(4.33)
(3.54)
(1.81)
(2.76)
T
76
B
(.75)
(.75)
110
90
46
70
19
19
(.43)
11
A
04
DHGM- 04X -20/2080/2090 Sub-plate
"C" Thd. "D" Thd. "E" Thd. "F" Thd.
Model Numbers
DHGM-04-20 Rc 1/2 Rc 1/4
190 DHGM-04X-20 Rc 3/4
(7.48) M10 M6
DHGM-04-2080 1/2 BSP.F
12(.47) 1/4 BSP.F
166 DHGM-04X-2080 3/4 BSP.F
(6.54)
32.2(1.27) 101.6
DHGM-04-2090 1/2 NPT 1/4 NPT 3/8-16 UNC 1/4-20 UNC
(4.00) DHGM-04X-2090 3/4 NPT
76.7
(3.02) 36
50 (1.42) 125
(1.97) (4.92)
"E" Thd. "C" Thd.
34(1.34) 17(.67) Deep 20 90 4 Places
4 Places (.79) (3.54)
21.5(.85)
18.3(.72) 19
33(1.30)
46
(.47)
1.6(.06)
(1.14)
(.75) (1.81)
12
(.52)
13.1
(.40)
29
10.1
(.63)
16
P
(2.56)
X
(2.99)
(2.19)
(2.25)
65
55.6
57.1
(3.54)
(4.72)
(3.78)
(2.81)
(2.75)
76
71.4
69.8
P X
120
90
96
T T
(.56)
14.2
A B Y Y B
A
No.26
Sub-plate for
Solenoid Controlled Pilot Operated DIRECTIONAL
Directional Valves CONTROLS
Installation Drawing
06
DHGM- 06X -50/5090 Sub-plate F
"C" Thd. "D" Thd. "E" Thd.
204 Model Numbers mm (in.)
(8.03)
DHGM-06-50 Rc 3/4
12 180 Rc 1/4 M12 24 (.94)
(.47) (7.09) DHGM-06X-50 Rc 1
25 130.2 DHGM-06-5090 3/4 NPT
(.98) (5.13) 1/4 NPT 1/2-13 UNC 26 (1.02)
DHGM-06X-5090 1 NPT
112.7
(4.44)
11(.43) Dia.
94.5 "D" Thd. (From Rear)
(3.72) 4 Places
77
(3.03)
53.2 "E" Thd. "F" Deep
6 Places
E
(2.09)
29.4(1.16)
5.6(.22)
TP Y
(3.81)
(4.57)
(3.63)
96.9
92.1
V
116
(2.94)
(2.88)
74.6
73.1
(1.81)
A B
46.1
X
19.1(.75)
17.5(.69)
(.47)
12
17.5 34(1.34)
11(.43) Dia. Through
(.69) 17.5(.69) Dia. Spotface
29.5 4 Places 35(1.38)
(1.16)
7(.28) Dia. 50
8(.31) Deep 100.8
(3.97) 23(.91) Dia. (1.97)
2 Places "C" Thd. (From Rear)
12.5 126.2 4 Places
(.49) (4.97)
156
(6.14) DIMENSIONS IN
MILLIMETRES (INCHES)
06
DHGM- 06X -5080
D
E
1/4 BSP.F Thd.
204 M12 Thd. 4 Places
24(.94) Deep F
(8.03)
6 Places
12 180 50 H
(.47) (7.09) (1.97)
25 130.2 35 J
(.98) (5.13) (1.38)
P T
(5.28)
(4.33)
(3.63)
(4.57)
T PY Y
92.1
134
110
116
V W V
(2.94)
(2.88)
(.47)
11.9
74.6
73.1
(1.81)
W B A
46.1
X A B X
(.35)
(.69)
(.75)
17.5
19.1
8.9
(.47)
12
12.5 N
(.49) 11(.43) Dia.
156 4 Places
(6.14) L
"C" Thd.
24.5(.96) Dia. 4 Places
4 Places K
No.27
Sub-plate for
Solenoid Controlled Pilot Operated DIRECTIONAL
Directional Valves CONTROLS
Installation Drawing
DHGM-10
10X-40/4080/4090
306.5
(12.07) DIMENSIONS IN
20(.79) 266.5 MILLIMETRES (INCHES)
(10.49)
38(1.50) 190.5
(7.50) 7 (.28) Dia. 8 (.31) Deep
168.3 2 Places
(6.63)
147.6
(5.81)
"E" Thd. 34 (1.34) Deep
114.3 213
6 Places
(4.50) (8.39)
76.2(3.00) F
60 "C" Thd.
41.3(1.63) (2.36) H 4 Places
Y P T
Y
(7.83)
(6.25)
158.8
V T P V
199
(4.87)
123.8
(4.50)
114.3
A B B A
(3.13)
W W
79.4
X X
(1.38)
(1.13)
"D" Thd.
28.6
35
43(1.69)
(.79)
20.1
4 Places
21.8 82.5 44(1.73) 55
(.86) (3.25) (2.17)
17.5 (.69) Dia. Through
11 (.43) Dia. 234
26 (1.02) Dia. Spotface K
4 Places (9.21)
4 Places
36 (1.42) Dia. J
4 Places
No.28
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-01, 03 CONTROLS
Spare Parts List
CAUTION
When making replacement of seals or pilot valves,
DSHG-01-∗∗∗-∗-13/1380/1390 please do it carefully after reading through the relevant
instructions in the Operator's Manual.
12
Pipe Plug
15 Removed for External Drain Models
Pipe Plug 12 14 17 16
Removed for External
Pilot Models
SOL b SOL a
18
E
13 Pipe Plug
Removed for Internal Pilot Models
2 5 4 10 11 8 3 1 7 6 13 Pipe Plug
Removed for Internal Drain Models
Note: Piece parts marked are not available
for internal pilot-internal drain type
DSHG-03-∗∗∗-∗-13/1390
15
14 17 16
Pipe Plug
Pipe Plug 13 Removed for Internal
13 Removed for Internal Drain Models
Pilot Models
SOL a SOL b
X Y
No.29
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-04,06,10 / S-DSHG-04,06,10 CONTROLS
Spare Parts List
CAUTION
(S-)DSHG-04-∗∗∗-∗-51/5190 When making replacement of seals or pilot valves,
15 please do it carefully after reading through the relevant
14 16 17 instructions in the Operator's Manual.
Pipe Plug
Pipe Plug Removed for Internal
11 Removed for Internal Pilot Models
Drain Models
SOL a SOL b 11
Y 12
X
(S-)DSHG-06-∗∗∗-∗-52/5290
(S-)DSHG-10-∗∗∗-∗-42/4290
15
Pipe Plug
16 14 17 Removed for Internal
Pipe Plug Drain Models
Removed for Internal
Pilot Models 11
11
SOL a SOL b
21 21
X
12
Y
X
12
Section X-X
Y 11 Pipe Plug
Section Y-Y
18 2 10 5 3 1 9 13 8 4 7 Removed for External
Drain Models
Note: When ordering the o-rings, please specify the seal kit number listed in page
31. In addition to the above o-rings, o-rings for pilot valve is included in the
seal kit.
For the detail of the pilot valve o-rings, see the catalogue No. Pub. EC-0402.
No.30
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG / S-DSHG CONTROLS
List of Pilot Valves & Seal Kits
Valve Model Numbers Pilot Valve Model Numbers Seal Kit Numbers
DSHG-01-3C∗- - -13 DSG-01-3C4- - -60
DSHG-01-3C∗- -N-1380
KS-DSHG-01- -13
DSG-01-3C4- -N-60
(For Internal Pilot-Internal Drain)
DSHG-01-3C∗- - -1390 DSG-01-3C4- - -6090
DSHG-01-2B∗- - -13 DSG-01-2B2- - -60-L
DSHG-01-2B∗- -N-1380
KS-DSHG-01-ET- -13
DSG-01-2B2- -N-60-L
(Except for Internal Pilot-Internal Drain)
DSHG-01-2B∗- - -1390 DSG-01-2B2- - -6090-L
DSHG-03-3C∗- - -13 DSG-01-3C4- - -60
DSHG-03-3C∗- - -1390 DSG-01-3C4- - -6090
DSHG-03-2B∗- - -13
E
DSG-01-2B2- - -60
KS-DSHG-03- -13
DSHG-03-2B∗- - -1390 DSG-01-2B2- - -6090
DSHG-03-2N∗- - -13 DSG-01-2D2- - -60
DSHG-03-2N∗- - -1390 DSG-01-2D2- - -6090
(S-)DSHG-04-3C∗- - -51 DSG-01-3C4- - -60
(S-)DSHG-04-3C∗- - -5190 DSG-01-3C4- - -6090
(S-)DSHG-04-2B∗- - -51 DSG-01-2B2- - -60
(S-)DSHG-04-2B∗- - -5190
KS-DSHG-04- -51
DSG-01-2B2- - -6090
(S-)DSHG-04-2N∗- - -51 DSG-01-2D2- - -60
(S-)DSHG-04-2N∗- - -5190 DSG-01-2D2- - -6090
(S-)DSHG-06-3C∗- - -52 DSG-01-3C4- - -60
(S-)DSHG-06-3C∗- - -5290 DSG-01-3C4- - -6090
(S-)DSHG-06-2B∗- - -52 DSG-01-2B2- - -60-L
KS-DSHG-06- -52
(S-)DSHG-06-2B∗- - -5290 DSG-01-2B2- - -6090-L
(S-)DSHG-06-2N∗- - -52 DSG-01-2D2- - -60
(S-)DSHG-06-2N∗- - -5290 DSG-01-2D2- - -6090
(S-)DSHG-10-3C∗- - -42 DSG-01-3C4- - -60
(S-)DSHG-10-3C∗- - -4290 DSG-01-3C4- - -6090
(S-)DSHG-10-2B∗- - -42 DSG-01-2B2- - -60-L
KS-DSHG-10- -42
(S-)DSHG-10-2B∗- - -4290 DSG-01-2B2- - -6090-L
(S-)DSHG-10-2N∗- - -42 DSG-01-2D2- - -60
(S-)DSHG-10-2N∗- - -4290 DSG-01-2D2- - -6090
Notes) 1: Fill coil type (a symbol representing current/voltage) in section marked . Likewise, in section marked , fill a symbol
representing the type of electrical conduit connection (None: Terminal Box Type, N: Plug-in Connector Type).
2: For the details of the pilot valves, see the catalogue No. Pub.EC-0402.
No.31
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
DSHG-01 / 03 CONTROLS
Interchangeability between Curent and New Design
DSHG-01, 03
In accordance with the improvement of the pilot valve (DSG-01), DSHG-01 and -03 have been model-changed (from
12-design to 13-design).
Current New
DSHG-01
210
(8.27) A
60 90 0.5 90 0.5
(2.36) (3.54) (.02) B
(3.54) (.02)
C
86 H
(3.29)
DSHG-03
210
A
(8.27)
0.5 90 60 0.5 90
B
(.02) (3.54) (2.36) (.02) (3.54)
(6.90)
175.3
175.3
77
H
(3.03)
Model No. A B H
AC 191.4 (7.54) 50.7 (2.00) 67.7 (2.67)
DSHG-03 DC 210 60 77
R (8.27) (2.36) (3.03)
No.32
Solenoid Controlled Pilot Operated
Directional Valves DIRECTIONAL
(S)-DSHG-04 / 06 / 10 CONTROLS
Interchangeability between Current and New Design
(S-)DSHG-04
(S-) DSHG-04 has been model changed in accordance with the improvement of the pilot valve (DSG-01).
For details, see the following.
Model No. Current New
Descriptions (S-)DSHG-04-∗∗∗-∗-50∗ (S-)DSHG-04-∗∗∗-∗-51∗
Specifications No changes
Interchangeability in Mtg. Yes
DSG-01-∗∗∗-∗-50∗ DSG-01-∗∗∗-∗-60∗
Pilot Valve
For details, refer to the Catalogue No. Pub. EC-0402.
Current New
210 AC : 191.4 (7.54)
(8.27) DC,R : 210 (8.27)
E
0.5 90 60 0.5 90 AC : 50.7 (2.00)
(.02) (3.54) (2.36) (.02) (3.54) DC,R : 60 (2.36)
(7.14)
181.3
181.3
53.4
(2.10) DIMENSIONS IN AC : 44.1 (1.74)
MILLIMETRES (INCHES) DC,R : 53.4 (2.10)
(S-)DSHG-06,10
(S-) DSHG-06 and -10 have been model changed in accordance with the improvement of the pilot valve (DSG-01).
For details, see below.
Model No. Current New
(S-)DSHG-06-∗∗∗-∗-51∗ (S-)DSHG-06-∗∗∗-∗-52∗
Descriptions (S-)DSHG-10-∗∗∗-∗-41∗ (S-)DSHG-10-∗∗∗-∗-42∗
Specifications No changes
Interchangeability in Mtg. Yes
DSG-01-∗∗∗-∗-50∗ DSG-01-∗∗∗-∗-60∗
Pilot Valve
For details, refer to the Catalogue No. Pub. EC-0402
Current New
210 A
(8.27)
0.5 90 60 0.5 90
(.02) (3.54) (2.36) (3.54) B
(.02)
A P B A P B
C
H
H
No.33
Pilot Operated Directional Valves
DHG-04 / 06 / 10 Sub-plate Mounting DIRECTIONAL
CONTROLS
Specifications / Instructions / Others
X Y
P
Specifications
Maximum Flow L /min (U.S.GPM) Max.Operating Max. Pilot Min. Required Max. T-Line Approx.
Model Numbers 10 MPa 16 MPa 25 MPa 31.5 MPa Pressure Pressure Pilot Pressure Back Pressure Mass
(1450 PSI) (2320 PSI) (3630 PSI) (4570 PSI) MPa (PSI) MPa (PSI) MPa (PSI) MPa (PSI) kg (lbs.)
DHG-04-3C∗-50∗
1 1 1 1
300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) 7.4 (16.3)
DHG-04-2N∗-50∗ 300 (79.3) 300 (79.3) 300 (79.3) 300 (79.3) 31.5 (4570) 25 (3630) 0.8 (120) 21 (3050) 7.4 (16.3)
DHG-04-2B∗-50∗ 130 (34.3) 70 (18.5) 70 (18.5) 60 (15.9) 7.8 (17.2)
DHG-06-3C∗-50∗ 500 (132)
2 2 2 2
500 (132) 500 (132) 500 (132) 11.2 (24.7)
DHG-06-2N∗-50∗ 500 (132)
4
500 (132) 500 (132) 500 (132) 25 (3630) 0.8 (120) 11.2 (24.7)
31.5 (4570) 21 (3050)
DHG-06-2B∗-50∗ 140 (37) 100 (26.4) 90 (23.8) 80 (21.1) 11.7 (25.8)
DHG-06-3H∗-50∗ 500 (132)
2
500 (132) 500 (132) 500 (132) 21 (3050) 1 (150) 12.0 (26.5)
DHG-10-3C∗-40∗ 1100 (291) 1100 (291) 1100 (291) 1100 (291)
3 3 3 3
43.8 (96.6)
DHG-10-2N∗-40∗ 1100 (291) 1100 (291) 1100 (291) 1100 (291)
4
25 (3630) 1 (150) 43.8 (96.6)
31.5 (4570) 21 (3050)
DHG-10-2B∗-40∗ 460 (122) 300 (79.3) 220 (58.1) 200 (52.8) 45.6 (101)
DHG-10-3H∗-40∗ 1100 (291) 1100 (291) 1100 (291) 1100 (291)
3 3
21 (3050) 1 (150) 51.6 (114)
Note: Max. flow in the table above represents 1. Varies depending on the spool type. For more information, see page 11
the value in the flow condition of P →A for the List of "Standard Model and Maximum Flow" (DSHG-04)
→ B → T (or P→ B→ A→ T) as shown in for Solenoid Controlled Pilot Operated Directional Valves.
the circuit diagram right. 2. Varies depending on the spool type and pilot pressure. For more
In case the valves is used in the condi- information, see page 12 for the List of "Standard Model and Maxi-
tion that eihter A or B port is blocked, mum Flow" (DSHG-06) related to the Solenoid Controlled Pilot Opera-
the maximum flow differs according to a A B
ted Directional Valves.
hydraulic circuit, therefore, please
X Y 3. Varies depending on the spool type and pilot pressure. For more
consult us for details. P T
information, see page 13 for the List of "Standard Model and Maxi-
mum Flow" (DSHG-10) related to the Solenoid Controlled Pilot Opera-
ted Directional Valves.
4. Minimum Pilot Pressure for the models with pilot piston is 1.8 MPa
(260PSI).
No.34
Pilot Operated Directional Valves
DHG-04/06/10 DIRECTIONAL
CONTROLS
Model Number Designation
E
plate 06 With C2 50 Refer to
type Direc- 2 N: 9 • 10 required)
Mount- Choke P2: With Pilot 5
fluids tional
(Omit ing No-Spring 11 • 12 Piston, Both
Valve Ends H:
if not B: Refer to
required) PA: With Pilot 4
Spring
Offset Piston, Port A
End
10 40
PB: With Pilot
1 Piston, Port B
Refer to End
1. For various combination, see the List of Valve Types below.
2. For the option combinations of the Type (Valve Size) and Options, see the List of Options below.
3. Refer to the column "valves using neutral position and side position" (Special 2-position valve) on page 36.
4. In spool-spring arrangement "H" (pressure centred models), in case the pilot pressure is more than 10 MPa (150PSI), please specify that the valve
should have the built-in orifice to the pilot line.
5. Design Standards: N Japanese Standard "JIS" and European Design Standard
one.................. N. American Design Standard
9
0......................
List of Valve Type List of Options
Valve Types Option Code
Model Numbers
Three Positions Two Positions 3H∗ C2 R2 RA RB P2 PA PB
Spring Pressure No- Spring DHG-04-3C∗
Centred Centred Spring Offset DHG-04-2N∗
Spool Type Graphic Symbols DHG-04-2B∗
DHG-06-3C∗
DHG-06-2N∗
A B A B A B A B
X
P T
Y X
P T
Y X
P T
Y X
P T Y DHG-06-2B∗
DHG-06-3H∗
V
6 3C6 3H6
60 3C60 3H60
9 3C9 3H9
10 3C10 3H10
11 3C11 3H11
12 3C12 3H12
: Pressure Centered Models are not available for the Valve Size of "04".
No.35
Pilot Operated Directional Valves
DHG-04 / 06 / 10 DIRECTIONAL
CONTROLS
Sub-plates / Mounting Bolts / Options
Sub-plate
Japanese Standard "JIS" European Design Standard N. American Design Standard
Valve
Model Approx. Approx. Approx.
Sub-plate Thread Sub-plate Thread Sub-plate Thread
Numbers Model Numbers Mass Mass Mass
Size Model Numbers Size Model Numbers Size
kg (lbs.) kg (lbs.) kg (lbs.)
DHG-04 DHGM-04-20 Rc 1/2 4.4 (9.7) DHGM-04-2080 1/2 BSP.F 4.4 (9.7) DHGM-04-2090 1/2 NPT 4.4 (9.7)
DHGM-04X-20 Rc 3/4 4.1 (9.0) DHGM-04X-2080 3/4 BSP.F 4.1 (9.0) DHGM-04X-2090 3/4 NPT 4.1 (9.0)
DHGM-06-50 Rc 3/4 7.4 (16.3) DHGM-06-5080 3/4 BSP.F 8.5 (18.7) DHGM-06-5090 3/4 NPT 7.4 (16.3)
DHG-06
DHGM-06X-50 Rc 1 7.4 (16.3) DHGM-06X-5080 1 BSP.F 8.5 (18.7) DHGM-06X-5090 1 NPT 7.4 (16.3)
DHGM-10-40 Rc 1-1/4 21.5 (47.4) DHGM-10-4080 1-1/4 BSP.F 21.5 (47.4) DHGM-10-4090 1-1/4 NPT 21.5 (47.4)
DHG-10 DHGM-10Y-40 Rc 1-1/2 21.5 (47.4) DHGM-10Y-4080 1-1/2 BSP.F 21.5 (47.4) DHGM-10X-4090 1-1/2 NPT 21.5 (47.4)
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
Sub-plates are shared with those for Solenoid Controlled Pilot Operated Directional Valves. Refer to pages 26 to 28 for dimensions.
Mounting Bolts
Socket Head Cap Screw
Model
Numbers Japanese Standard "JIS" Tightening Torque
N. American Desgin Standard Qty.
European Design Standard Nm (in. lbs)
M6 × 45 Lg. 1/4-20 UNC × 1-3/4 Lg. 2 12-15 (106-133)
DHG-04
M10 × 50 Lg. 3/8-16 UNC × 2 Lg. 4 58-72 (513-637)
DHG-06 M12 × 60 Lg. 1/2-13 UNC × 2-1/2 Lg. 6 100-123 (885-1089)
DHG-10 M20 × 75 Lg. 3/8-16 UNC × 2 Lg. 6 473-585 (4186-5177)
Options
Models with Pilot Choke Adjustment (C2) Pressure Centered Models (3H∗)
When the adjustment screw is turned clockwise, changeover speed The pressure centred type can be used when the returning of the spool
of the spool becomes slow. In case of the spring centred valves in to the neutral position is required to be done firmly.
particular, making slow of the returning speed of the spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with valves of spring Graphic Symbol
centred, no spring, spring offset, pressure centred and the valves with
stroke adjustment. A B
Graphic Symbols X V Y
P T
Spring Centred Models
A B
No.36
Pilot Operated Directional Valves
DHG-04/06/10 DIRECTIONAL
CONTROLS
Special Two Position / Installation Drawing
Valves Using Neutral Position and Side Position (Special Two Position Valve)
In addition to the standard two positions valves (2B∗), the following two types of two positions valves are
available: valves with neutral position and pilot Y pressure position (2B∗A), valves with neutral position and pilot
X pressure position (2B∗B).
DHG-∗-2B2A DHG-∗-2B2B
DHG-∗-2B3A DHG-∗-2B3B
DHG-∗-2B4A DHG-∗-2B4B
E
DHG-∗-2B40A DHG-∗-2B40B
DHG-∗-2B5A DHG-∗-2B5B
DHG-∗-2B6A DHG-∗-2B6B
DHG-∗-2B60A DHG-∗-2B60B
DHG-∗-2B7A DHG-∗-2B7B
DHG-∗-2B9A DHG-∗-2B9B
DHG-∗-2B10A DHG-∗-2B10B
DHG-∗-2B11A DHG-∗-2B11B
DHG-∗-2B12A DHG-∗-2B12B
73(2.87)
91(3.58)
DEC.
DIMENSIONS IN
MILLIMETRES (INCHES) Fully Extended
Y 9.3 10.4 59
A B
(.37) (.41) (2.32)
(.06)
50
1.6
Cylinder
Port "A" (1.97)
Pilot Pressure Port "Y"
(5.75)
(1.34)
35
34
(O-Rings Furnished) Two Locating Pins it functions as drain port. When that model
is used, directly connect it to the reservoir.
Note: For the valve mounting surface dimensions, see the dimensional drawing of the
sharable sub-plate on page 26.
No.37
Pilot Operated Directional Valves
DHG-06 / 10 DIRECTIONAL
CONTROLS
Installation Drawing
DHG-06-∗∗∗-50/5090 Mounting surface: ISO 4401-AE-08-4-A
(3.63)
19.7 (.78)
(4.65)
92.1
118
(1.81)
46.1
(.51)
13
(6.57)
167
(5.00)
77
127
Pilot Pressure (3.03)
Port "X" Cylinder Port "B"
156
(6.14)
Cylinder Port "A" Indicates Spring Offset
Models (2B∗).
Pressure Centred Models (3H∗)
Models with Stroke Adjustment (R∗)
255 52 Indicates Spring Offset
(10.04) (2.05) Models (2B∗A).
65 95 34 48
(1.89)
Models with Pilot Piston (P∗)
(2.56) (3.74) (1.34)
The outside dimensions of the above options are the same
as those of the main valve of Solenoid Controlled Pilot
Operated Directional Valve (DSHG-06). See page 25.
(5.59)
142
X A B
. In case of Spring Offset Model (2B∗, 2B∗A), it
(1.61)
41
B
functions as a drain port. When that model is used,
directly connect it to the reservoir.
(.24)
6
(7.80)
158.8
198
(3.13)
79.4
(.77)
19.6
21.8 114.3 78
(9.06)
230
(7.48)
(.86) (4.50)
190
(3.07)
233.8
(9.20) Cylinder Port "B"
Pilot Pressure
Port "X" Cylinder Port "A" Indicates Spring Offset
Models (2B∗).
384
84
(3.31)
Indicates Spring Offset
Models (2B∗A).
Pressure Centred Models (3H∗)
(15.12) 48
(1.89)
Models with Stroke Adjustment (R∗)
Models with Pilot Piston (P∗)
65 159.5 66.5
(2.56) (6.28) (2.62)
The outside dimensions of the above options are the same
as those of the main valve of Solenoid Controlled Pilot
2-Eye Bolts Operated Directional Valves (DSHG-10). See page 25.
46 (1.81)
(8.07)
205
6(.24) Dia.
(O-Rings Furnished) Two Location Pins
Note: For the valve mounting surface dimensions, see the dimensional drawing of
the sharable sub-plate in page 28.
No.38
Pilot Operated Directional Valves
DHG-04/06/10 DIRECTIONAL
CONTROLS
Spare Parts List
CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.
DHG-04-∗∗∗-50/5090
DHG-06-∗∗∗-50/5090
6 8 15 16 17 13
DHG-10-∗∗∗-40/4090
2 11 5 10 1 3 14 9 4 12 7
Part Numbers
Item Name of Parts Qty
DHG-04 DHG-06 DHG-10
9 O-Ring SO-NB-P9 SO-NB-P14 SO-NB-P20 2
10 O-Ring SO-NB-P22 SO-NB-P30 SO-NB-P42 4
11 O-Ring SO-NB-P34 SO-NB-P40 SO-NB-G65 2
12 O-Ring SO-NB-P9 SO-NB-P10 SO-NB-P14 2
13 O-Ring SO-NB-P9 SO-NB-P9 SO-NB-P9 4
Note: When ordering the o-rings, please specify the seal kit number from the table
below.
No.39
Manually Operated Directional Valves
DMT- 03 / 06 / 10
DMG-01 / 03 / 04 / 06 / 10 DIRECTIONAL
Thread Connection / Sub-plate Mounting CONTROLS
Specifications
Specifications
Maximum Flow L /min (U.S.GPM) Max.Operating Max. T-Line Back Approx.
Model Numbers 7 MPa 14 MPa 21 MPa 31.5 MPa Pressure Pressure Mass
(1020 PSI) (2030 PSI) (3050 PSI) (4570 PSI) MPa (PSI) MPa (PSI) kg (lbs.)
DMT-03-3C∗-50∗
1 1 1
100 (26.4) 100 (26.4) 100 (26.4)
DMT-03-3D∗-50∗ 100 (26.4) 100 (26.4) 100 (26.4)
25 (3630) 16 (2320) 5.0 (11.0)
DMT-03-2D∗-50∗ 100 (26.4) 100 (26.4) 100 (26.4)
DMT-03-2B∗-50∗
1 1 1
100 (26.4) 100 (26.4) 100 (26.4)
Threaded Connections
DMG-04-3C∗-21∗
3 3 3
200 (52.8) 200 (52.8) 105 (27.7)
DMG-04-3D∗-21∗ 200 (52.8) 200 (52.8) 200 (52.8) 6 7.4 (16.3)
21 (3050) 21 (3050)
DMG-04-2D∗-21∗ 200 (52.8) 200 (52.8) 200 (52.8)
DMG-04-2B∗-21∗ 90 (23.8) 60 (15.9) 50 (13.2) 7.9 (17.4)
DMG-06-3C∗-50∗ 500 (132) 500 (132) 500 (132) 500 (132)
DMG-06-3D∗-50∗ 500 (132) 500 (132) 500 (132) 500 (132) 6 11.5 (25.4)
31.5 (4570) 21 (3050)
DMG-06-2D∗-50∗ 500 (132) 500 (132) 500 (132) 500 (132)
DMG-06-2B∗-50∗ 420 (111) 300 (79.3) 250 (66.1) 200 (52.8) 12 (26.5)
DMG-10-3C∗-40∗
4 4 4 4
1100 (291) 1100 (291) 1100 (291) 1100 (291)
DMG-10-3D∗-40∗ 1100 (291) 1100 (291) 1100 (291) 1100 (291) 6 48.2 (106)
31.5 (4570) 21 (3050)
DMG-10-2D∗-40∗ 1100 (291) 1100 (291) 1100 (291) 1100 (291)
DMG-10-2B∗-40∗ 670 (177) 350 (92.5) 260 (68.7) 200 (52.8) 50 (110)
Note: The maximum flow means the limited flow without inducing any abnormality to the operation
(changeover) of the valve. For details, please refer to the "List of Standard Models and Maximum DMG-01 Lever Operating Torque
Flow" on pages 9 to 13.
(in.lbf.) Nm
Operating Torque
1. Varies depending on the spool type. For details, see the "List of Standard Model and Maximum 12 1.5
Flows" for DSG-03 Series Solenoid Operated Directional Valves (catalogue No. Pub EC-0403,
at 50 Hz rated voltage). 8 1.0
2. The figures in parentheses indicate Max. flow for 3C3,3C5, 3C6 and 3C60. 4 0.5
0 0
3. Varies depending on the spool type. For the details, see the table in the following page. 0 5 10 14 MPa
4. Varies depending on the spool type. Same as DSHG-10 (at pilot pressure of 1.5 MPa (220 PSI). 0 500 100015002000 PSI
See page 13. T-Line Back Pressure
5. Lever operating torque varies depends on the T-line back pressure. See the right-hand figure.
6. If the T-Line back pressure exceeds 7 MPa (1020 PSI), directly connect the drain port to the
reservoir.
No.40
Manually Operated Directional Valves
DMT-03/06/10 DIRECTIONAL
DMG-01/03/04/06/10 CONTROLS
Model Number Designation / Others
Model Number Designation
F- DM T -03 -2 B 2 A -50 ∗
Type of No. of Special Two
Special Series Valve Spool-Spring Spool Design Design
Connec- Valve Position
Seals Number Size Arragement Type Number Standard
tion Position Valve
03 50 None: Japanese
T: C: Std. "JIS"
F: 06 (Piping size 3/4) Spring
Threaded 2 • 3 30 80: European
Special 06X (Piping size 1) Centred
Connec- 4 • 40 Design Std.
Seals for tion 10 (Piping size 1-1/4) 3 90: N. American
DM: 5 • 6 A ,B 30
Phos- 10X (Piping size 1-1/2) D: Design Std.
Manually 60 • 7 (Omit if not
phate No-Spring
Operated 01 required) 10
ester Detented 8 • 9 None: Japanese
Direc- 03 2 50
type 10 • 11 Std. "JIS"
E
tional 04 21 and Euro-
fluids G: B: 12
Valves pean Design
(Omit if Sub-plate 06 Spring Offset 50
Std.
not Mounting 10
required) 90: N. American
40
Design Std.
See the table below for combinations.
Refer to column "valves using neutral position and side position" (special 2-position valve) on page 42.
4
Maximum Flow of DMG-04-3C∗
40
Model Max. Flow L /min (U.S.GPM)
Numbers 7 MPa(1020 PSI) 14 MPa(2030 PSI) 21 MPa(3050 PSI)
DMG-04-3C2 200 (52.8) 130 (34.3) 85 (22.5) 5
DMG-04-3C3 180 (47.6) 90 (23.8) 70 (18.5)
DMG-04-3C4 200 (52.8) 200 (52.8) 90 (23.8)
DMG-04-3C40 200 (52.8) 200 (52.8) 105 (27.7) 6
DMG-04-3C5 80 (21.1) 50 (13.2) 40 (10.6)
DMG-04-3C6 90 (23.8) 60 (15.9) 55 (14.5)
DMG-04-3C60 140 (37.0) 70 (18.5) 55 (14.5)
60
DMG-04-3C7 200 (52.8) 75 (19.8) 55 (14.5)
DMG-04-3C9 200 (52.8) 125 (33.0) 100 (26.4)
DMG-04-3C10 200 (52.8) 130 (34.3) 85 (22.5) 7
DMG-04-3C11 200 (52.8) 150 (39.6) 85 (22.5)
8
DMG-04-3C12 200 (52.8) 200 (52.8) 95 (25.1)
9
Graphic Symbols
Spring Centred Models (3C∗) 10
#1 #2 #3
A B 11
P T 12
No-Spring Detented Models
3D∗ 2D∗
#1 #2 #3 #1 (#2) #3
Position #3
A B A B Position #2
G-01/03-2B∗, DMG-03-2D∗)
Position #1 (#2, in case of DMT T
P T P T Note: The mark indicate the spool type available for each type.
Spring Offset Models (2B∗)
. Position #2 is applied for models DMG-01-2B∗
#1 (#2) #3
A B
and DMT G-03-2B∗/2D∗.
P T
No.41
Manually Operated Directional Valves
DMT-03/06/10 DIRECTIONAL
DMG-01/03/04/06/10 CONTROLS
Valves Using Neutral Position and Side Position
Valves Using Neutral Position and Side Position (Special Two Position Valve)
In addition to the standard two positions valves (2D∗, 2B∗), the following two types of two positions valves are
available: Valves with neutral position (#2) and position #1 (2B∗A, 2D∗A), valves with neutral position (#2) and
position #3 (2B∗B, 2D∗B).
The mark in the table below indicates the spool type available for each models.
2B5B
2B5A
2B6A 2B6B
2B60A 2B60B
2B7A 2B7B
2B8A 2B8B
2B9A 2B9B
2B10A 2B10B
2B11A 2B11B
2B12A 2B12B
Position #1 Position #2
Position #2 Position #3
2D5B
2D5A
2D6A 2D6B
2D60A 2D60B
2D7A 2D7B
2D8A 2D8B
2D9A 2D9B
2D10A 2D10B
2D11A 2D11B
2D12A 2D12B
Position #1 Position #2
Position #2 Position #3
. Position number is determined with three position type (3C∗ and 3D∗) as the standard.
No.42
Manually Operated Directional Valves
DMG-01/03/04/06/10 DIRECTIONAL
DMT-06 CONTROLS
Sub-plates / Mounting Bolts / Pressure Drop
Sub-plates
Japanese Standard "JIS" European Design Standard N. American Design Standard
Valve
Approx. Approx. Approx.
Model Sub-plate Thread Sub-plate Thread Sub-plate Thread
Mass Mass Mass
Numbers Model Numbers Size Model Numbers Size Model Numbers Size
kg (1bs.) kg (1bs.) kg (1bs.)
DSGM-01-30 Rc 1/8 0.8 (1.8) DSGM-01-3080 1/8 BSP.F 0.8 (1.8) DSGM-01-3090 1/8 NPT 0.8 (1.8)
DMG-01 DSGM-01X-30 Rc 1/4 0.8 (1.8) DSGM-01X-3080 1/4 BSP.F 0.8 (1.8) DSGM-01X-3090 1/4 NPT 0.8 (1.8)
DSGM-01Y-30 Rc 3/8 0.8 (1.8) DSGM-01Y-3090 3/8 NPT 0.8 (1.8)
DSGM-03-40 Rc 3/8 3.0 (6.6) DSGM-03-2180 3/8 BSP.F 3.0 (6.6) DSGM-03-2190 3/8 NPT 3.0 (6.6)
DMG-03 DSGM-03X-40 Rc 1/2 3.0 (6.6) DSGM-03X-2180 1/2 BSP.F 3.0 (6.6) DSGM-03X-2190 1/2 NPT 3.0 (6.6)
DSGM-03Y-40 Rc 3/4 4.7 (10.4) DSGM-03Y-2180 3/4 BSP.F 4.7 (10.4) DSGM-03Y-2190 3/4 NPT 4.7 (10.4)
DHGM-04-20 Rc 1/2 4.4 (9.7) DHGM-04-2080 1/2 BSP.F 4.4 (9.7) DHGM-04-2090 1/2 NPT 4.4 (9.7)
DMG-04
DHGM-04X-20 Rc 3/4 4.1 (9.0) DHGM-04X-2080 3/4 BSP.F 4.1 (9.0) DHGM-04X-2090 3/4 NPT 4.1 (9.0)
E
DHGM-06-50 Rc 3/4 7.4 (16.3) DHGM-06-5080 3/4 BSP.F 8.5 (18.7) DHGM-06-5090 3/4 NPT 7.4 (16.3)
DMG-06
DHGM-06X-50 Rc 1 7.4 (16.3) DHGM-06X-5080 1 BSP.F 8.5 (18.7) DHGM-06X-5090 1 NPT 7.4 (16.3)
DHGM-10-40 Rc 1-1/4 21.5 (47.4) DHGM-10-4080 1-1/4 BSP.F 21.5 (47.4) DHGM-10-4090 1-1/4 NPT 21.5 (47.4)
DMG-10
DHGM-10X-40 Rc 1-1/2 21.5 (47.4) DHGM-10X-4080 1-1/2 BSP.F 21.5 (47.4) DHGM-10X-4090 1-1/2 NPT 21.5 (47.4)
Sub-plates are available. Specify the sub-plate model number from the table above. Sub-plate dimensions appearing page
When sub-plates are not used, the mounting surface should have a good machined finish. Subplate Model Numbers Page
Sharable with Solenoid Operand Directional Valves and Solenoid Controlled Pilot Operated DSGM-01∗ 18
Directional Valves. For dimensions, refer to the right table then see the corresponding pages. DSGM-03∗ 47
DHGM-04∗ 26
Mounting Bolts DHGM-06∗ 27
DHGM-10∗ 28
Valve Socket Head Cap Screw
Model Japanese Standard "JIS" N. American Tightening Torque
Qty.
Numbers European Design Standard Design Standard Nm (in. 1bs.) Instructions
DMG-01 M5 × 45 Lg. No. 10-24 UNC × 1-3/4 Lg. 4 5-7 (44-62) Avoid connecting the
DMG-03 M6 × 35 Lg. 1/4-20 UNC × 1-3/4 Lg. 4 12-15 (106-133) Tank Port "T" to a line with
M6 × 40 Lg. 1/4-20 UNC × 1-1/2 Lg. 2 12-15 (106-133) possible surge pressure.
DMG-04
M10 × 45 Lg. 3/8-16 UNC × 1-3/4 Lg. 4 58-72 (513-637)
DMG-06 M12 × 60 Lg. 1/2-13 UNC × 2-1/2 Lg. 6 100-123 (885-1089)
DMG-10 M20 × 75 Lg. 3/4-10 UNC × 3 Lg. 8 473-585 (4195-5177)
Pressure Drop
The following characteristics are based on the following conditions: viscosity of the fluid: 35 mm2/s (164 SSU) and
Specific Gravity: 0.850
For any other viscosity, multiply the factors in the table below.
mm2/s 15 20 30 40 50 60 70 80 90 100
Viscosity
SSU 77 98 141 186 232 278 324 371 417 464
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula below.
P' = P (G'/G) where, P is a value on the following chart and G is 0.
850. Spool Pressure Drop Curve Number
DMT-06, 06X Type P → A B → T P → B A→ T P → T
PSI MPa 1 2 2 2 2 2
150
1.0 2 3 3 2 3 2 2
P
4 2 3 2 2
0.8
Pressure Drop
100 3 40 2 2 2 2
0.6 5 3 2 2 2
6 3 2 3 2 1
50 0.4
60 3 2 3 2 1
0.2 7 2 2 2 2
0 8 2 2
0 0 50 100 150 200 250 300 L /min 9 3 2 3 2
10 2 2 2 2
11 3 2 2 2
0 20 40 60 80 U.S.GPM
12 2 2 2 2
Flow Rate
No.43
Manually Operated Directional Valves
DMT-10 DIRECTIONAL
DMG-01/04 CONTROLS
Pressure Drop
4 3 2 3 2
Pressure Drop
0.8
100 40 3 2 3 2
0.6 5 3 2 3 2
2
6 3 3 3 3 1
0.4 3
50 60 3 3 3 3 1
0.2 7 3 2 3 2
0 8 3 3
0
0 100 200 300 400 500 L /min 9 3 2 3 2
10 3 2 3 2
0 20 40 60 80 100 120130 U.S.GPM 11 3 2 3 2
Flow Rate 12 3 2 3 2
1.2
2 3C5 3D5 2 1 1 1 3
150
Pressure Drop
1.0
3C60 3D60 1 1 1 1 3
0.8 3
100 3C7 3D7 2D7 3 3 3 3
0.6
3C8 3D8 2D8 3 3
0.4 3C9 3D9 3 3 3 3
50
0.2 3C10 3D10 3 3 3 3
0 3C11 3D11 3 3 3 3
0
0 5 10 15 20 25 30 35 L /min
3C12 3D12 3 3 3 3
2B2 2 2 3 3
0 2 4 6 8 9 U.S.GPM
2B3 2 2 3 3
Flow Rate 2B8 3 3
150 4 4 5 4 5 5
1.0
Pressure Drop
5 40 5 4 5 5
0.8
100 6 5 5 2 4 5 1
0.6 6 2 3 4 2 1
0.4 60 2 3 4 2 1
50
0.2 7 5 2 5 5
0 9 6 2 6 5
0
0 50 100 150 200 L /min
10 5 4 5 5
11 5 4 5 5
0 10 20 30 40 50 U.S.GPM
12 5 3 5 5
Flow Rate
For DMT-03, DMG-03, DMG-06, and DMG-10, refer to the table below then see the related page.
Model Number Pressure Drop Characteristics Page Remarks
DMT-03 Same as DSG-03 Series Solenoid Operated Directional Valves Catalogue
DMG-03 (Standard Type) No. Pub. EC-0403
Same as Solenoid Controlled Pilot Operated Directional Valves
DMG-06 16 3D∗ is same as 3C∗
(DSHG-06)
Same as Solenoid Controlled Pilot Operated Directional Valves
DMG-10 16
(DSHG-10)
No.44
Manually Operated Directional Valves
DMT-03 / 06 / 10 DIRECTIONAL
CONTROLS
Installation Drawing
69.7 54
DMT-03-∗∗∗-50/5080/5090 (2.74) (2.13) Pressure Port "P"
44 "C" Thd.
How to Change Lever Position: (1.73)
27 7(.28) Dia. Through
30°
(1.06) 11(.43) C' bore
Cylinder Port "A" 4 Places
"C" Thd. 10
The lever position can 30°
(.47)
(.39)
12
be changed to any Soc. Hd. Cap Screw
position in five 4 (.16) Hex. Soc.
different positions
(1.06)
(2.76)
27
(1.81)
shown on the sketch in 30°
70
46
the right. For the lever
position change,
remove the Soc. Hd.
Cap Screw and lever
(0.8)
2
once, set the lever at 30° 48.7
the required position (1.92) Cylinder Port "B"
and tighten it with the 108.5 "C" Thd.
Soc. Hd. Cap Screw (4.27) Tank Port "T"
firmly. 30° 193.8 "C" Thd.
E
(7.63)
Position #1
74.5 Position #2 30° 1. Lever Operating Torque:
(2.93) 20° Not exceeding 30 Nm (266 IN. 1bs.)
27
(1.06) Position #3 20°
1
25 (.98) Dia. R94.5
(R3.72)
Model Numbers "C" Thd.
DMT-03-∗∗∗-50 Rc 3/8
(5.47)
139
(3.36)
85.3
DMT-03-∗∗∗-5090 3/8 NPT
(1.82)
46.3
(1.06)
27
DIMENSIONS IN
(1.06)
(.86)
21.8
26.8
39.7 19
MILLIMETRES (INCHES) (1.56) (.75)
92
(3.62)
A B
T
R "e"
"f" Dia. Through D
"g" Dia. Spotface Position #1 Neutral Position #2
4 Places
Model Numbers "h" Thd. C C 40 (1.57) Dia.
DMT-06-∗∗∗-30
Tank Port "T"
Rc 3/4 Position #3
DMT-06X-∗∗∗-30 Rc 1
DMT-06-∗∗∗-3080 3/4 BSP.F U V
DMT-06X-∗∗∗-3080 1 BSP.F J
DMT-06-∗∗∗-3090
K
3/4 NPT L N
DMT-06X-∗∗∗-3090 1 NPT Q
a
S S
DMT-10-∗∗∗-30 Rc 1-1/4
DMT-10X-∗∗∗-30 Rc 1-1/2
DMT-10-∗∗∗-3080 1-1/4 BSP.F
Z
No.45
Manually Operated Directional Valves
DMG-01 DIRECTIONAL
CONTROLS
Installation Drawing
DMG-01-∗∗∗-10/1090
Mounting surface: ISO 4401-AB-03-4-A
(1.22) (.03)
0.75
27°
(.61)
15.5
(1.28)
Neutral Position #2
32.5
31
27°
Position #1
Tank Port "T"
Cylinder Port "B"
The operating lever position can be adjusted as required
on the circumference by loosening the set screw.
5
(.20) 26 (1.02) Dia.
20 (.79) Dia. Lever Fixing Screw
2.5 (.10) Hex. Soc.
(1.54)
39
(2.91)
74
(1.99)
50.5
(1.50)
38
(.98)
25
65
(2.56)
Mounting Surface
48 (O-Rings Furnished)
(1.89)
Note: For the valve mounting surface dimensions, see the dimensional drawing of the sharable sub-plate in page 18.
No.46
Manually Operated Directional Valves
DMG-03 DIRECTIONAL
CONTROLS
Installation Drawing
DMG-03-∗∗∗-50/5090
Mounting surface: ISO 4401-AC-05-4-A
(.47)
(2.74) (2.13)
12
(1.28)
32.5
(1.81)
(2.76)
46
70
74.5 3 1
(2.93) 48.7 50.8 Tank Port "T" 1. Although the tank port is shown on the left
27 (1.92) (2.00) in our sub-plate either may be used.
(1.06) 108.5
(4.27) 2. The position of operating lever can be
E
25 (.98) Dia. 193.8 changed as required. For the detail, see the
(7.63) DMT-03 in the previous page.
Position #1
30°
3. Lever Operating Torque:
Position #2 Not exceeding 30 Nm (266 IN. 1bs.)
2 °
0
°
20
Position #3
R94.5
(R3.72)
39.7
2 (.08)
(1.56)
(5.47)
X
139
View Arrow X
(3.00)
76.3
(2.32)
(1.82)
59
46.3
(1.06)
27
19
(.75) Mounting Surface
92 (O-Rings Furnished)
Sub- plates (3.62)
DSGM-03∗-40/2180/2190
J 90 DIMENSIONS IN
(3.54) MILLIMETRES (INCHES)
18 54
(.71) (2.13)
37.3
"D" Thd. "E" Deep
(1.47)
8.8 (.35) Dia. Through 27 4 Places
14 (.55) Dia. Spotface (1.06)
4 Places K L
16.7
T N
(.66)
3.2 7 P
(.79)
(.39)
(.87)
20
(.13) (.28)
10
22
S
(.25)
6.4
P
(.84)
Q
21.4
(1.28)
(2.99)
(3.54)
32.5
(4.33)
(2.76)
(1.81)
76
110
90
70
46
B
A T
H 92
11 (.43) Dia. (3.62) "C" Thd.
4 Places F 4 Places
No.47
Manually Operated Directional Valves
DMG-04 / 06 DIRECTIONAL
CONTROLS
Installation Drawing
DMG-04-∗∗∗-21/2190
Mounting surface: ISO 4401-AD-07-4-A
Tank Port "T" 130
14.2 (5.12)
(.56) 101.6 Pressure Port "P"
(4.00)
34
11(.43) Dia. Through Cylinder Port "B"
(1.34)
17.5(.69) Dia. Spotface
4 Places
(3.54)
(2.87)
(2.75)
72.9
69.8
90
(1.37)
34.9
Position #2
Position #3
(.06)
(.40)
10.1
32 32 50
1.5
(1.97) 7(.28) Dia. Through
40 (1.57) Dia. (1.26) (1.26)
Position #1 11(.43) Dia. Spotface
2 Places Drain Port "Y"
Cylinder Port "A"
22.5
30 (1.18) 232.5 (9.15) Chain line indicates
202.5 (7.97) (.89)
R200 Spring Offset Models
59.2
(R7.87)
(2.33) (2B∗,2B∗A).
(1.97)
(4.06)
50
103
(1.26)
(1.18)
(.16)
30
32
A B
Mounting Surface
3(.12) Dia. (O-Rings Furnished)
Two Locating Pins
Note: For the valve mounting surface dimensions, see the dimensional drawing of the sharable sub-plate in page 26.
DIMENSIONS IN
MILLIMETRES (INCHES)
DMG-06-∗∗∗-50/5090 Mounting surface: ISO 4401-AE-08-4-A
Pressure Port "P"
300.5
(11.83)
95.8 130.2
(3.77) (5.13) 13.5(.53) Dia. Through
Tank Port "T" 53.2 20(.79) Dia. Spotface
(2.09) 6 Places
Drain Port "V" Y
T P
(3.63)
(4.65)
92.1
118
(1.81)
46.1
X A B
(.51)
13
Position #2 260.5 52
(10.26) (2.05)
30 (1.18) 57 57 34
Position #3 (2.24) (2.24) (1.34) Indicates Spring Offset
Position #1 Models (2B∗).
(4.57)
47
116
(1.61)
41
40
(.24)
12.5
6
Mounting Surface
6(.24) Dia. (.49) (O-Rings Furnished)
Two Locating Pins 156
(6.14)
Note: For the valve mounting surface dimensions, see the dimensional drawing of the sharable sub-plate in page 27.
No.48
Manually Operated Directional Valves
DMG-10 DIRECTIONAL
CONTROLS
Installation Drawing
DMG-10-∗∗∗-50/5090
Mounting surface: ISO 4401-AF-10-4-A
DIMENSIONS IN 453
(17.83)
MILLIMETRES (INCHES)
146.5 190.5
(5.77) (7.50)
76.2 21.5(.85) Dia. Through
Tank Port "T" (3.00) 32(1.26) Dia. Spotface
6 Places
T Y P
(7.80)
(6.24)
158.8
198
(3.13)
79.4
X A B
Drain Port "V"
(.77)
19.6
E
94.5 114.3
(3.72) (4.50) Cylinder Port "B"
Cylinder Port "A"
401 66.5
Position #2 (15.79) (2.62)
36 (1.42) 105 105 47.5
Indicates Spring Offset
Models (2B∗)
(4.13) (4.13) Position #1 (1.87)
Position #3
40 (1.57) Dia.
Two Eye Bolts Indicates Spring Offset
M8 Models (2B∗A)
R300
(R11.81)
(2.56) (2.36)
(.24) 44.5 (1.75)
(7.09)
180
65 60
21.5
6
Mounting Surface
6(.24) Dia. (.85) (O-Rings Furnished)
Two Locating Pins 233.8
(9.20)
Note: For the valve mounting surface dimensions, see the dimensional drawing of the sharable sub-plate in page 28.
No.49
Manually Operated Directional Valves
DMG-01/03 DIRECTIONAL
DMT-03 CONTROLS
Spare Parts List
CAUTION
When making replacement of seals, please do it
carefully after reading through the relevant
DMG-01-∗∗∗-10/1090 instructions in the Operator's Manual.
14 13 9 12 X 18 10 17 15 16
21
22
25
24
20
Section X-X
19 3 X 8 6 5 23 2 1 21 11 4
DMT-03-∗∗∗-50/5080/5090
DMG-03-∗∗∗-50/5090
28 20 3 14 29 30 10 9
26 17 25 11 13
27
13
24
23
22 15 16 12 2 6 21 1 5 18 8 14 4
Item Name of Parts Part Numbers Qty. Valve Model Numbers Seal Kit Numbers
14 O-Ring SO-NB-P21 2 DMT-03-∗∗∗-50/5080/5090 KS-DMT-03-50
15 O-Ring SO-NA-P8 2 DMG-03-∗∗∗-50/5090 KS-DMG-03-50
16 Back Up Ring SO-BB-P8 2
17 O-Ring SO-NB-A023 1
18 O-Ring SO-NB-A014 5
Note: 1. O-rings of Item 18 are not used for
DMT-03.
2. When ordering the seals, please specify
the seal kit number from the table right.
No.50
Manually Operated Directional Valves
DMT-06/10 DIRECTIONAL
DMG-04/06/10 CONTROLS
Spare Parts List
22
5
14
7 21 13 15 23 16 2 4 17 1 26 24 12 25
6
E
18
19
20
Part Numbers
Item Name of Parts Qty.
DMT-06∗ DMT-10∗
24 Packing UPI 32 • 40 • 6Y UPI 40 • 55 • 10Y 2
25 Dust Seal DKI 32 • 44 • 7 • 10 DKI 40 • 52 • 7 • 10 1
Note: When ordering the seals, please specify the seal kit number from the table below.
DMG-04-∗∗∗-21/2190
DMG-06-∗∗∗-50/5090
DMG-10-∗∗∗-40/4090 A
28 26 9 22 23 10 33 36 17 1 6 33
31
22
15
28
Section A-A 24 A
21 2 11 29 32 30 25 29 3 20
No.51