0% found this document useful (0 votes)
716 views9 pages

2.pile - Cap.design Columns

This document summarizes the design calculations for a pile cap supporting a column. Key details include: - The pile cap has dimensions of 750mm x 750mm with 450mm diameter piles spaced 1350mm apart. - The column above applies an axial load of 1800kN. - Reinforcement requirements are calculated using truss and flexural theories. Main reinforcement of 9 bars of 20mm diameter is determined to provide adequate strength. - Shear capacity is verified to exceed the shear demand from the applied load. Shear links are not required but nominal links will be provided at 200mm spacing. - Side face reinforcement of 2 bars of 16mm diameter is specified.

Uploaded by

taha abu el hana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
716 views9 pages

2.pile - Cap.design Columns

This document summarizes the design calculations for a pile cap supporting a column. Key details include: - The pile cap has dimensions of 750mm x 750mm with 450mm diameter piles spaced 1350mm apart. - The column above applies an axial load of 1800kN. - Reinforcement requirements are calculated using truss and flexural theories. Main reinforcement of 9 bars of 20mm diameter is determined to provide adequate strength. - Shear capacity is verified to exceed the shear demand from the applied load. Shear links are not required but nominal links will be provided at 200mm spacing. - Side face reinforcement of 2 bars of 16mm diameter is specified.

Uploaded by

taha abu el hana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 9

Project Job ref

Part of structure Calc sheet no rev


/ 0
Drawing ref. Calc by Date Check by Date
May-23 Nov-09

Ref Calculations Output

Design of pile cap - PC4


Line of critical shear
Dia. Of pile = 450 mm B
Offest from pile = 150 mm
Column width = 600 mm
Pile spacing (2L) = 1350 mm Φ/5
Depth of pile cap = 750 mm
Width of pile cap (B) = 750 mm 2L
Bottom cover = 75 mm
Side cover = 50 mm
Ultimate axial load (N) = 1800 kN

Materials
fcu = 35 N/mm2
fy = 500 N/mm2
Gm = 1.25 (partial saftey factor for concrete - shear)
Gm = 1.15 (partial saftey factor for steel)

Design for main reinforcement:


Effective depth of pile cap (d) = 653 mm

According to Truss theory:


Tension to be resisted by main reinforcement, T = (N x L) / (2 x d)
= 1800 x 675 / (2 x 653)
= 930.3 kN

According to Flexural theory:


Moment parallel to X axis = 607.5 kNm
K = M / fcu b d2 = 0.054
Z = d(0.5 + √(0.25 - K / 0.9)) = 611.14 mm

Therefore Tx = 994.0 kN

Area of steel required = T / (0.87 x fy)


= 994040 / (0.87 x 500)
= 2286 mm2
Dia. Of bars using for main reinforcement = 20 mm
No. of bars required = 7.277
Provide No. of bars = 9 Nos
Area of steel provided = 2827 mm2 OK
BS 8110 Spacing of main bars = 78.25 mm
Table 3.25 Percentage of steel = 0.503 % > 0.13 % OK
Project Job ref
Newport Station Regeneration 5074908
Part of structure Calc sheet no rev
Car Park - Design of Pile Caps for Columns 9/ 9 / 0
Drawing ref. Calc by Date Check by Date
SJ Jun 08 CMN Jun-08

Ref Calculations Output

Check for shear:


Shear stress along critical section (v) = (N / 2) / (B x d)
= (1800 / 2) / (750 x 653)
3.4.5.2 = 1.838 N/mm2 < 5 N/mm2 OK
BS 8110
Table 3.8 100 As / bv d = 0.577 %
Design strength of concrete for shear resistance = 35 N/mm2
(400 / d) (1/4)
= 0.885
Design shear resistance ( vc) = 0.52 N/mm2
Critical section from face of the column (av) = (675 - 300 - 0.3 x 450)
= 240 mm
3.4.5.8 Enhanced shear stress = 2.834 N/mm2 > 1.838 OK

Hence, shear links are not required. However provide nominal T12 links @ 200 c/c.

Side face reinforcement:


3.12.5.4 Dia. Of bar used for side face reinforcement = 16 mm
Spacing of bar = ( ϕ2 x fy ) / b
= 256 mm
Hence, provide side face reinforcement - 2 nos. T16 bars
Project Job ref

Part of structure Calc sheet no rev


/ 0
Drawing ref. Calc by Date Check by Date
BVR May-23 Nov-09

Ref Calculations Output

Design of pile cap - PC2 (For 750x300 column) Y av


Φ/5
Dia. Of pile ( Φ ) = 450 mm av
Offest from pile = 150 mm
Column width in X-direction = 600 mm
Column width in Y-direction = 600 mm
Effective length of pile cap (2 Lx) = 1350 mm 2100 2Ly 750
Effective length of pile cap (2 Ly) = 1350 mm Φ
Depth of pile cap = 750 mm
Bottom cover = 75 mm
Side cover = 50 mm
Ultimate axial load (N) = 3500 kN 2Lx X
Reaction of each pile (N/3) = 1167 kN
2100
Materials
fcu = 35 N/mm2 Gm = 1.25 (partial saftey factor for concrete - shear)
fy = 500 N/mm2 Gm = 1.15 (partial saftey factor for steel)

Design for main reinforcement:


Effective depth of pile cap (d) = 637.5 mm

According to Truss theory:


Effective length of pile cap (2 Lxy) = 1509 mm
Tension to be resisted by main reinforcement, Txy = (2N x Lxy) / (9 x d)
= 2 x 3500 x 754.675 / (9 x 637.5)
= 920.74 kN
Tension to be resisted by main reinforcement, Ty = (2N x Ly) / (9 x d)
= 2 x 3500 x 675 / (9 x 637.5)
= 823.53 kN
Net tension to be resisted by main reinforcement, Tx = 2 x Txy cos 26.57
= 2 x 920.74 x cos 26.57
= 1647.1 kN
Net tension to be resisted by main reinforcement, Ty = 2 x Txy sin 26.57 + 823.53
= 1647.1 kN
According to Flexural theory:
Moment parallel to X axis = 700 kNm
K = M / fcu b d2 = 0.023
Z = d(0.5 + √(0.25 - K / 0.9)) = 605.63 mm

Moment parallel to Y axis = 437.5 kNm


K = M / fcu b d2 = 0.015
Z = d(0.5 + √(0.25 - K / 0.9)) = 605.63 mm
Therefore Tx = 1155.8 kN
Therefore Ty = 722.39 kN

In X-direction
Area of steel required in X-direction = Tx / (0.87 x fy)
= 1647100 / (0.87 x 500)
= 3786 mm2
Dia. Of bars using for main reinforcement = 25 mm
No. of bars required = 7.7137
Provide No. of bars = 14 Nos
Area of steel provided = 6872 mm2 OK Provide
BS 8110-1 Spacing of main bars = 153.8 mm 14 Nos. T25 bars
Table 3.25 Percentage of steel = 0.44 % > 0.13 % OK
Project Job ref
Newport Station Regeneration 5074908
Part of structure Calc sheet no rev
Car Park - Design of Pile Caps for Columns 5/ 9 / 0
Drawing ref. Calc by Date Check by Date
SJ Jun 08 CMN Jun-08

Ref Calculations Output

In Y-direction
Area of steel required in Y-direction = Ty / (0.87 x fy)
= 1647100 / (0.87 x 500)
= 3786 mm2
Dia. Of bars using for main reinforcement = 25 mm
No. of bars required = 7.7137
Provide No. of bars = 14 Nos
Area of steel provided = 6872 mm2 OK Provide
Spacing of main bars = 150 mm 14 Nos. T25 bars
Percentage of steel = 0.44 % > 0.13 % OK

Check for shear:


Shear stress along critical section (v) = (2 N/3) / (B x d)
= 2 (3500000 / 3) / (2100 x 637.5)
3.4.5.2 = 1.74 N/mm2 < 5 N/mm2 OK
BS 8110
Table 3.8 100 As / bv d = 0.52 %
Design strength of concrete for shear resistance = 35 N/mm2
(400 / d) (1/4) = 0.89
Design shear resistance ( vc) = 0.51 N/mm2
Critical section from face of the column (av) = (2/3)x1350 - 600/2 - 0.3x450
= 465 mm
3.4.5.8 Enhanced shear stress = 1.4 N/mm2 < 1.74 0

Hence, shear links are required

Check for punching shear:


At column face:
Punching stress = N / (u d)
Perimeter of column (u) = 2400 mm
Punching stress = 2.29 N/mm2 < 5 N/mm2 OK

At Φ/5 from pile face:


Punching stress = N / (u d)
Critical perimeter (u) = 3558.7 mm
Punching stress = 1.54 N/mm2
Enhanced shear stress = 1.39 N/mm2 0

Hence, shear links are required

Side face reinforcement:


3.12.5.4 Dia. Of bar used for side face reinforcement = 16 mm
Spacing of bar = ( ϕ 2 x fy ) / b
= 256 mm

Hence, provide side face reinforcement - 2 nos. T16 bars


Project Job ref
Extreme Piling Tech.
Part of structure Calc sheet no rev
Tel.: +974 4451 0007-8-9 /0
Fax : +974 4451 0006 Drawing ref. Date Check by Date
Email : [email protected] May-23 May-15

Ref Calculations Output

Design of pile cap - PC1 Y av2

Dia. Of pile ( Φ ) = 300 mm


Offest from pile = 100 mm
Column width in X-direction = 600 mm av1
Column width in Y-direction = 600 mm
Pile spacing in X-direction (2 Lx) = 800 mm 1300 2Ly
Pile spacing in Y-direction (2 Ly) = 800 mm
Depth of pile cap = 750 mm
Bottom cover = 75 mm
Side cover = 50 mm
Ultimate axial load (N) = 272 kN 2Lx X
K' = 0.156
1300

Materials
fcu = 32 N/mm2
fy = 500 N/mm2
Gm = 1.25 (partial saftey factor for concrete - shear)
Gm = 1.15 (partial saftey factor for steel)

Design for main reinforcement:


Effective depth of pile cap (d) = 669 mm

According to Truss theory:


Reynolds Tension to be resisted by main reinforcement, Ty = (2 N Ly)/(4 d)
Hand book = 2 x 272 x 400 / (4 x 669)
= 81.32 kN
Tension to be resisted by main reinforcement, Tx = (2 N Lx)/(4 d)
= 2 x 272 x 400 / (4 x 657)
= 82.8 kN

According to Flexural theory:


Moment parallel to Y axis = 13.6 kNm
K = M / fcu b d2 = 0.001
Z = d(0.5 + √(0.25 - K / 0.9)) = 635.55 mm

Moment parallel to X axis = 13.6 kNm


K = M / fcu b d2 = 0.001
Z = d(0.5 + √(0.25 - K / 0.9)) = 624.15 mm

Therefore Ty = 21.4 kN
Therefore Tx = 21.8 kN

In Y-direction
Area of steel required in Y-direction = Ty / (0.87 x fy)
= 81320 / (0.87 x 500)
= 186.94 mm2
Dia. of bars for main reinforcement = 12 mm
No. of bars required = 1.6529
Provide No. of bars = 12 Nos
Area of steel provided = 1357 mm2 OK Provide
BS 8110-1 Spacing of main bars = 109.09 mm 12 Nos. T12 bars
Table 3.25 Percentage of steel = 0.14 % > 0.13 % OK
Project Job ref
Extreme Piling Tech.
Part of structure Calc sheet no rev
Tel.: +974 4451 0007-8-9 /0
Fax : +974 4451 0006 Drawing ref. Date Check by Date
Email : [email protected] May-23 May-15

Ref Calculations Output

In X-direction
Area of steel required in X-direction = Tx / (0.87 x fy)
= 82800 / (0.87 x 500)
= 190.34 mm2
Dia. of bars for main reinforcement = 12 mm
No. of bars required = 1.683
Provide No. of bars = 12 Nos
Area of steel provided = 1357 mm2 OK Provide
BS 8110-1 Spacing of main bars = 106.91 mm 12 Nos. T12 bars
Table 3.25 Percentage of steel = 0.14 % > 0.13 % OK

Check for shear in Y-direction:


Shear stress along critical section (v) = (N / 2) / (Bx x d)
= (272000 / 2) / (1300 x 669)
= 0.16 N/mm2 < 5 N/mm2 OK

Table 3.8 100 As / bv d = 0.16 %


Design strength of concrete for shear resistance = 32 N/mm2
(400 / d) (1/4)
= 0.88
Design shear resistance ( vc) = 0.33 N/mm2
Critical section from face of the column (a v) = 800/2 - 600/2 - 0.3*300
= 10 mm
3.11.4.4.a Enhanced shear stress = 2 d vc / av = 43.83 N/mm2 > 0.16 OK

Hence, shear links are not required.

Check for shear in X-direction:


Shear stress along critical section (v) = (N / 2) / (By x d)
= (272000 / 2) / (1300 x 657)
3.4.5.2 = 0.16 N/mm2 < 5 N/mm2 OK
BS 8110
Table 3.8 100 As / bv d = 0.16 %
Design strength of concrete for shear resistance = 32 N/mm2
(400 / d) (1/4) = 1
Design shear resistance ( vc) = 0.37 N/mm2
3.11.4.4.a Critical section from face of the column (a v) = 800/2 - 600/2 - 0.3*300
= 10 mm
3.4.5.8 Enhanced shear stress = 2 d vc / av = 48.95 N/mm2 > 0.16 OK

Hence, shear links are not required.

Check for punching shear:


At column face:
Punching stress = N / (u d)
Perimeter of column (u) = 2400 mm
Punching stress = 0.17 N/mm2 < 5 N/mm2 OK

Side face reinforcement:


3.12.5.4 Dia. Of bar used for side face reinforcement = 12 mm
Spacing of bar = ( ϕ2 x fy ) / 500
= 144 mm
Hence, provide side face reinforcement - 2 nos. T16 bars