Ground Floor Plan Electrical and Sanitary Layout
Ground Floor Plan Electrical and Sanitary Layout
ELECTRICAL LEGEND
WATER CONNECTION
SYMBOL DESCRIPTION SYMBOL DESCRIPTION
MUNICIPAL CONNECTION GI 55 mm. Ø
BOWSER CONNECTION GI 55 mm. Ø FLUORESCENT 45 Amp. COOKER
TUBE LIGHT SOCKET AND SWITCH
DISTRIBUTOR DOWN TAKE 36 mm. Ø
DISTRIBUTOR FOR BATH / TOILET / KITCHEN 25 mm. Ø FLUORESCENT
CEILING FAN
CONNECTION TO BATH, WATER HEATER 22 mm. Ø DOUBLE TUBE LIGHT
CONNECTION FOR OTHER INDIVIDUAL UNITS 15 mm. Ø
DRAINAGE CONNECTION WALL LIGHT WALL FAN
22222
22222
316
1) NECESSARY REDUCER TO BE PROVIDED WHERE EVER ONE WAY SWITCH CALL BELL
n Denotes no of Gangs
REQUIRED TO MAINTAIN WATER PRESSURE
2) WATER HEATER AND EXHAUST FAN AT LEVEL 220 OBOVE.
MAIN DISTRIBUTION
n TWO WAY SWITCH
BOARD
n Denotes no of Gangs
ELECTRICAL NOTES:-
T.V. SOCKET AND
T.V. POSITION
SWITCH
1. EXACT LOCATION / POSITION SHALL BE DETERMINED AT SITE WITH CONSULTANT
ENGINEER / OWNER.
WATER HEATER
SWITCH DISH POSITION
NESSARY REDUCER TO BE PROVIDED WHERE EVER REQUIRED
316
2. ALL SYMBOLS MARKED ON THE DRG. SHOW TENTATIVE LOCATION / POSITION OF IN SIDE CAMERA OUT SIDE CAMERA
THE ELECTRICAL ACCESSORIES , EQUIPMENT AND LIGHTING FIXTURES ETC.
3. ALL ELECTRICAL FITTINGS & FIXTURES SHALL BE OF APPROVED QUALITY DENOTES WEATHER
MANUFACTURE / DESIGN. WP WATER HEATER
PROOF
4. EACH LIGHT & FAN SHALL BE OPERATED BY AN INDIVIDUAL SWITCH.
316
338
5. STAIRCASE LIGHTING SHALL BE OPERATED BY TWO WAY SWITCH.
EL WINDOW AC
338 EMERGENCY LIGHT
6. ALL LIGHTING SWITCHES & SOCKET OUTLETS SHALL BE OF BEST QUALITY
AND MAKE MK/MEM / LEGRAND OR EQUAL & APPROVED UNLESS OTHERWISE BOUNDARY WALL
SPECIFIED. FLOOR LIGHT
LIGHT
BOUNDARY WALL LIGHTS BOUNDARY WALL LIGHTS
7. EACH FLOOR / BLOCK SHALL BE PROVIDED WITH SEPARATE
OUTSIDE LIGHTS OUTSIDE LIGHTS
DISTRIBUTION BOARD. CEILING LIGHT (LED)
9 22222
22222 9
BD
9. METERING PANEL BOARD SHALL BE PROVIDED OUTSIDE THE BLDG. IN IP 56
WEATHER PROOF HINGED TYPE ENCLOSURE WITH VISION PANEL AND LOCKING
2
FT FT FACILITY.
10. ALL EXTERNAL LIGHTING CONTROL SWITCHES SHALL BE PROVIDED WITH TIMER
INSIDE THE BUILDING AT NEAREST LOCATION OR OWNER'S REQUIREMENT.
11. ALL LIGHTING SWITCH BOXES & SOCKET OUTLET BOXES SHALL BE PROVIDED WITH
BRASS EARTHING TAG. TO CONNECT EARTH WIRES.
12. THE CONTRACTOR HAS TO PROVIDE CONDUITS COMPLETE WITH WIRING FOR
TELEPHONE & T.V. ANTENNA NETWORK TO OWNER'S REQUIREMENT.
ELECTRICAL AND SANITARY LAYOUT 13. ALL THE ELECTRICAL INSTALLATION SHALL BE CARRIED OUT IN
ACCORDANCE WITH LATEST I.E.E. & MHEW RULES & REGULATIONS.
14. ALL WATER HEATERS SHOULD BE LOCATED AT A HEIGHT OF 2.20 M. ABOVE THE
SANITARY & PLUMBING LEGEND
GROUND FLOOR PLAN FLOOR LEVEL
SCALE 1:100 3
4 " Ø COLD WATER PIPE
(CONCEALED)
WASHING MACHINE
16. SPLIT A/C PROVISION TO BE PROVIDED AT ALL ROOMS MAJLIS HALL
DETAILS NO. UNIT K.W DETAILS NO. UNIT K.W SHOWER WITH TAP W.C. (ARABIC) E-MAIL : [email protected]
AIR CONDITIONERS 00 2.5 00 AIR CONDITIONERS 00 2.5 00 GAS CYLINDER GT GULLY TRAP
OWNER -
WATER HEATERS 01 1.5 1.5 WATER HEATERS 01 1.5 1.5 SINK WITH DRAIN BOARD MH
INSPECTION CHAMBER USE PLOT NO. LOCATION
WITH C.I. COVER 647 BARKA
INDUSTRIAL
SOCKET OUTLETS 10 0.2 2 SOCKET OUTLETS 10 0.2 2 SOIL / WASTE / VENT / FT FLOOR TRAP
PHASE 1-EXT SAQSUQ
P.V.C. / C.I. PIPE Title - NO. FLOOR
COOKERS 00 4.0 0 COOKERS 00 4.0 0 ELECTRICAL AND SANITARY LAYOUT
GROUND
WASHBASIN MARBLE TOP GROUND FLOOR PLAN
FINISHING BELOW
EXHAUST FANS 01 0.1 0.1 EXHAUST FANS 01 0.1 0.1 COVERED SHELF
DESIGNED BY CHECKED BY DATE
NS NS 12-2022
TOTAL 7.70 TOTAL 7.70 DRAWN BY APPROVED BY Scale
NS ENG. Y. AL - BARHI 1 : 100
Job no. Drg. No. REV. NO.
2022-SK EL - 01 -