Val SK e
Val SK e
& Valvair II
Solenoid & Pilot Operated
Directional Spool Valves
Catalog VAL-SK-E/USA
April 2004 (Revised April 2006)
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED
HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide
product and/or system options for further investigation by users having technical expertise. It is important that you analyze
all aspects of your application including consequences of any failure, and review the information concerning the product or
system in the current product catalog. Due to the variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products
and systems and assuring that all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document entitled “Offer of Sale”.
Pressure Exhaust
L 44 5 2 9 10 2 53
53 120 110
Note: Shaded options Operator Options
1 Solenoid (Basic) or Remote
57 240 220
L 67 5 3 9 10 2 53
53 120 110
Note: Shaded options Operator Options
57 240 220
1 Solenoid (Basic) or Remote
have been discontinued. 2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
Refer to back of Catalog 7 Solenoid w/Light (120VAC, 24VDC) 2
Duty Cycle
Standard Service
L 51 5 5 9 10 2 53
Type Operator Size Enclosure “Class” Voltage & Frequency
38 Single 4 Remote 4 * 1/2" Basic Poppet 10 Standard 60Hz 50Hz DC
(Poppet) 5 Solenoid 5 † 1/2" Basic (NEMA 1 & 12) 45 12
51 Double or Remote
* Only available with
54 Single Type 38. 49 24
†
Available with Type 51 53 120 110
& 54.
57 240 220
L 42 5 2 9 21 1 53
Type Operator Size Voltage & Frequency
42 Double 4 Remote 2 1/4" Basic 60Hz 50Hz DC
5 Solenoid 45 12
49 24
53 120 110
Operator Options
57 240 220
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override Enclosure “Class”
3 Solenoid w/Locking Override 21 All Ports Blocked in Neutral Duty Cycle
7 Solenoid w/Light (120VAC, 24VDC) (NEMA 1 & 12 Enclosure) or Remote
1 Standard Service
8 Solenoid w/Light (120VAC, 24VDC) 22 Cyl. Ports Open to Exh. in Neutral Solenoid or
& Non-Locking Override (NEMA 1 & 12 Enclosure) or Remote Remote
9 Solenoid w/Light (120VAC, 24VDC) 23 Cyl. Ports Open to Inlet in Neutral 5 Continuous
& Locking Override (NEMA 1 & 12 Enclosure) or Remote Service Solenoid
L 66 5 3 9 21 1 53
Type Operator Size Enclosure “Class” Voltage & Frequency
66 Double 4 Remote 3 3/8" Basic 21 All Ports Blocked in 60Hz 50Hz DC
5 Solenoid 8 1" Basic Neutral (NEMA 1 & 45 12
12 Enclosure) or
Remote 49 24
22 Cyl. Ports Open to
Note: Shaded Exh. in Neutral
(NEMA 1 & 12
53
57
120
240
110
220
Operator Options
options have been 1 Solenoid (Basic) or Remote
Enclosure) or Remote
23* Cyl. Ports Open to
L 52 5 5 9 21 1 53
Type Operator Size Voltage & Frequency
52 Double 4 Remote 5 1/2" Basic 60Hz 50Hz DC
5 Solenoid 45 12
49 24
53 120 110
Operator Options
57 240 220
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override Enclosure “Class”
3 Solenoid w/Locking Override 21 All Ports Blocked in Neutral Duty Cycle
7 Solenoid w/Light (120VAC, 24VDC) (NEMA 1 & 12 Enclosure) or Remote
1 Standard Service
8 Solenoid w/Light (120VAC, 24VDC) 22 Cyl. Ports Open to Exh. in Neutral Solenoid or
& Non-Locking Override (NEMA 1 & 12 Enclosure) or Remote Remote
9 Solenoid w/Light (120VAC, 24VDC) 23 Cyl. Ports Open to Inlet in Neutral 5 Continuous
& Locking Override (NEMA 1 & 12 Enclosure) or Remote Service Solenoid
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, see valve. It will remain in this position until a “momentary”
Optional Functions page. signal is applied to the other solenoid. For alternative
flow path usages, service, see Optional
Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to Mounting
base is automatic. Air & electrical connections remain These valves are designed for subbase or manifold
undisturbed if valve is removed. Order from chart below. mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve
Operation: Pressure Service spool to be in horizontal plane. Order from chart below.
De-energized (normal condition) – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E. Operation: Pressure Service
Energized (maintained signal applied) – Pressure at With solenoid “A” having been energized last –
Port P is connected to “Cylinder” Port B, “Cylinder” Port A Pressure at Port P is connected to “Cylinder” Port A.
is connected to “Exhaust” Port E. “Cylinder” Port B is connected to “Exhaust” Port E.
Energize solenoid “B” (momentary) – Pressure at Port
P is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
A B Sol A A B Sol B
P E P E
6.65
168.9mm Single Solenoid
2.90 See Manifold Section for
73.7mm
.56 .56 Manifold Dimensional Data
14.2mm 14.2mm
CYL A CYL B
Wiring Diagram
1.09 Parts List
27.7mm
2.19 (–) (+) Item Part No. Description
55.6mm 2 No.
1 3
2 K18R311093 Retaining Ring
EXH IN 3 K453 006 Spacer
1.22 .27 Dia.
31.0mm 6.8mm * 4 — O-Ring
2 Holes
2.20 5 K453 005 Spacer
55.9mm
3.31 * 6 — Seal
84.1mm
7 K232 018 Spool Assy.
* 8 — Seal
18
14
*11 — Gasket
13 13 H175 12 Lockwasher
21 11 14 H100 60 Cap Screw
6.20 *15 — Gasket
20 157.5mm
19 18 K152 003 Override Assy.
1/2 Pipe 15 19 H175 12 Lockwasher
Conduit
Connection
20 H100 59 Cap Screw
.97 1.50 21 K983 001 Shock Pad
24.6mm EXH IN 38.1mm
.75
* Standard Service Kit: K352 150
1.33
19.0mm 33.8mm * Special Service Kit: K352 350
4 5 3 2 6 7 8 2.66 (Continuous Duty)
67.6mm
6.74
171.2mm Double Solenoid
3.00 See Manifold Section for
76.2mm
.56 .56 Manifold Dimensional Data
14.2mm 14.2mm
CYL A CYL B
1.09
27.7mm SOL A SOL B Wiring Diagram
2.19
55.6mm
Sol. A Sol. B
(+)
(–) 2 (–)
Parts List
EXH IN 1 3
1.22 .27 Dia. Item
6.8mm Part No. Description
31.0mm No.
2 Holes
2.20
55.9mm * 2 — O-Ring
3.31 3 K453 005 Spacer
84.1mm
4 K493 005 Spool
17 * 5 — Seal
11 * 8 — Gasket
10
10 H175 12 Lockwasher
8 11 H100 60 Cap Screw
6.20
14 157.5mm *12 — Gasket
13 13 H175 12 Lockwasher
1/2 Pipe 12
Conduit 14 H100 59 Cap Screw
Connection
17 K152 003 Override Assy.
.97 1.50
24.6mm EXH IN 38.1mm 18 K983 001 Shock Pad
.75 1.33 * Standard Service Kit: K352 151
19.0mm 33.8mm * Special Service Kit: K352 351
2 3 4 5 18 2.66 (Continuous Duty)
67.6mm
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, such valve. It will remain in this position until a “momentary”
as dual pressure service, see Optional Functions page. signal is applied to the other solenoid. For alternative
flow path usages, such as dual pressure service, see
Optional Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to Mounting
base is automatic. Air & electrical connections remain These valves are designed for subbase or manifold
undisturbed if valve is removed. Order from chart below. mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve
Operation: Pressure Service spool to be in horizontal plane. Order from chart below.
De-energized (normal condition) – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB. Operation: Pressure Service
Energized (maintained signal applied) – Pressure at With solenoid “A” having been energized last –
Port P is connected to “Cylinder” Port B, “Cylinder” Port Pressure at Port P is connected to “Cylinder” Port A.
A is connected to “Exhaust” Port EA. “Cylinder” Port B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary) – Pressure at Port
P is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
A B Sol B A B Sol A
EA P EB EA P EB
Model Selection
Valve Only Subbase Manifold ▲ Port Size
Voltage (Side Ports) (End & Bottom Ports) (NPT)
Single Solenoid Double Solenoid
120V 60Hz K022 090 K142 230 3/8"
L675 39 102 53 L655 39 102 53
110V 50Hz K022 091 K142 231 1/2"
L675 33 102 ** L655 33 102 ** Other K022 101 K142 270 3/4"
7.38
187.5mm Double Solenoid
2.94 3.32 See Manifold Section for
74.7mm 84.3mm Manifold Dimensional Data
1/2 Pipe .34 Dia.
Conduit 1.12 1.12
28.4mm 28.4mm 8.6mm
Connection 2 Holes
Wiring Diagram
CND A B
1.44 1.34 Sol. A Sol. B
36.6mm 34.0mm (+) (–) (+) (–)
2.88 2.84
73.2mm SOL. B SOL. A
72.1mm 1 2 3 4
Parts List
EA P X EB
Item
Part No. Description
.38 .75 No.
9.7mm 19.1mm
2.00 2.00 * 2 — O-Ring (Dynamic)
50.8mm 50.8mm
3.16 3 K453 028 Spacer
80.3mm
6.03 4 K463 012 End Spacer
153.2mm
5 K343 094 Spool
* 6 — Seal
18
* 8 — Gasket
11
10 10 H175 12 Lockwasher
20 11 H100 60 Cap Screw
8 19
6.93 *12 — Gasket
176.0mm
18 K152 003 Override Assy.
23 1/2 Pipe
Conduit 19 H175 12 Lockwasher
12 Connection
20 H100 69 Cap Screw
*21 — O-Ring (Static)
1.75
1.00
44.5mm 23 K983 002 Shock Pad
25.4mm
* Standard Service Kit: K352 126
.62 .75
4 21 2 3 5 6 15.7mm 19.1mm * Special Service Kit: K352 127
(Continuous Duty)
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, such as valve. It will remain in this position until a “momentary”
dual pressure service, see Optional Functions page. signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see Optional
Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to Mounting
base is automatic. Air & electrical connections remain These valves are designed for subbase or manifold
undisturbed if valve is removed. Order from chart below. mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve spool
Operation: Pressure Service to be in horizontal plane. Order from chart below.
De-energized (normal condition) – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB. Operation: Pressure Service
Energized (maintained signal applied) – Pressure at With solenoid “A” having been energized last – Pressure
Port P is connected to “Cylinder” Port B, “Cylinder” Port A at Port P is connected to “Cylinder” Port A. “Cylinder” Port
is connected to “Exhaust” Port EA. B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary) – Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
A B Sol B A B Sol A
EA P EB EA P EB
120V 60Hz
L545 59 102 53 L515 59 102 53 K022 092 K142 233 1/2"
110V 50Hz
L545 53 102 ** L515 53 102 ** Other K022 093 K142 234 3/4"
See page 4 for variations and ( ▲ - Manifolds include mounting hardware.
**) voltage codes.
Parts List
8.62
218.9mm
Single Solenoid Item
2.69 4.18 See Manifold Section for Part No. Description
68.3mm 106.2mm Manifold Dimensional Data No.
1/2 Pipe .34 Dia.
Conduit .88 2.31 8.6mm 2 K18R311137 Retaining Ring
Connection 22.4mm 58.7mm 2 Holes
Wiring Diagram 3 K553 011 Washer
CYL A
CYL B
1.56 1.44
* 4 — O-Ring
39.6mm 36.6mm
(–) (+)
3.25
5 K453 008 Spacer
82.6mm
3.00 1 2 3 4
76.2mm 6 K463 001 End Spacer
7 K232 017 Spool Assy.
EXH IN EXH
* 8 — Seal
1.62 2.03 * 9 — Seal
41.1mm 51.6mm
3.25 *12 — Gasket
82.6mm
6.25 14 H175 12 Lockwasher
158.8mm
15 H100 60 Cap Screw
*16 — Gasket
22
22 K152 003 Override Assy.
15 23 H175 16 Washer
25
12 14 24 H100 25 Cap Screw
24 7.05 25 K983 003 Shock Pad
23 179.1mm
* Standard Service Kit: K352 152
16 * Special Service Kit: K352 352
(Continuous Duty)
1.53
.84 38.9 mm
X
21.3mm
1.00 .50
25.4mm 12.7mm
9 8 2 3 7 45 6
8.07
205.0mm
Double Solenoid
3.13 3.83 See Manifold Section for
1/2 Pipe 79.5mm 97.3mm .34 Dia. Manifold Dimensional Data
Conduit 1.31 1.88 8.6mm
Connection 33.3mm 47.8mm 2 Holes
CYL A
1.56
CYL B
Wiring Diagram
1.44
39.6mm 36.6mm Sol. A Sol. B
3.25 3.00
82.6mm SOL. B SOL. A
76.2mm (+) (–) (+) (–)
1 2 3 4
EXH IN EXH
.44
11.2mm Parts List
1.62 2.03
41.1mm 51.6mm Item
3.25 Part No. Description
82.6mm No.
6.25
158.8mm 2 K463 001 End Spacer
* 3 — O-Ring
4 K453 008 Spacer
5 K343 046 Spool
18
* 6 — Seal
11
* 8 — Gasket
8 10
10 H175 12 Lockwasher
20 7.05
19 179.1mm 11 H100 60 Cap Screw
21 *12 — Gasket
12 18 K152 003 Override Assy.
19 H175 16 Washer
1.53
.84 38.9mm 20 H101 25 Cap Screw
X
21.3mm
21 K983 003 Shock Pad
1.00 .50
25.4mm 12.7mm * Standard Service Kit: K352 153
6 2 3 4 5 21 * Special Service Kit: K352 353
(Continuous Duty)
Application
These valves may be used to actuate a double acting
cylinder. A maintained electrical signal shifts the valve.
When this signal is removed the valve returns to its
normal condition. For alternate flow path usages, such as
dual pressure service, see Optional Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve
to base is automatic. Air & electrical connections remain
undisturbed if valve is removed. Order from chart below.
A B
EA P EB
120V 60Hz
L385 49 102 53 K022 092 K142 233 1/2"
110V 50Hz
L385 43 102 ** Other K022 093 K142 234 3/4"
See page 4 for variations and ( ▲ - Manifolds include mounting hardware.
**) voltage codes.
5
18 30 23 K473 032 Spring
17 24 K242 002 Poppet Assy.
6 X
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, such as valve. It will remain in this position until a “momentary”
dual pressure service, see Optional Functions page. signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see Optional
Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Electrical connection from valve to Mounting
base is automatic. Air & electrical connections remain These valves are designed for subbase or manifold
undisturbed if valve is removed. Order from chart below. mountings. Electrical connection from valve to base is
automatic. Air & electrical connections remain
undisturbed if valve is removed. Axis of main valve spool
Operation: Pressure Service to be in horizontal plane. Order from chart below.
De-energized (normal condition) – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB. Operation: Pressure Service
Energized (maintained signal applied) – Pressure at With solenoid “A” having been energized last – Pressure
Port P is connected to “Cylinder” Port B, “Cylinder” Port A at Port P is connected to “Cylinder” Port A. “Cylinder”
is connected to “Exhaust” Port EA. Port B is connected to “Exhaust” Port EB.
Energize solenoid “B” (momentary) – Pressure at Port P
is connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
A B Sol B A B Sol A
EA P EB EA P EB
See page 3 for variations and ( ▲ - Manifolds include mounting hardware, except for port adapters.
**) voltage codes. See chart, order separately.
1.22 .59
31.0mm 15.0mm
10 9 2 3 4 5 68 7
9.50
241.3mm Double Solenoid
3.38 4.75 See Manifold Section for
85.8mm 120.6mm
1/2-14 Pipe Manifold Dimensional Data
Conduit 1.53 1.53
Connection 38.9mm 38.9mm
CYL. A CYL. B
2.28 2.44
57.9mm 62.0mm Wiring Diagram
4.56 4.28
115.8mm SOL. B SOL. A
108.7mm Sol. A Sol. B
(+) (–) (+) (–)
1 2 3 4
EXH EXH Parts List
2.46 2.45 .39 Dia. Item Part No. Description
62.5mm 62.2mm 9.9mm No.
3.81 2 Holes
96.8mm 2 K463 005 End Spacer
7.62
193.5mm * 3 — O-Ring (Dynamic)
* 4 — O-Ring (Static)
19 5 K453 009 Spacer
12
6 K343 061 Spool
9 22 11 * 7 — Seal
* 9 — Gasket
21 8.74
222.0mm 11 H175 12 Lockwasher
20
12 H100 60 Cap Screw
13
*13 — Gasket
19 K152 003 Override Assy.
2.09
1.31 53.1mm 20 H175 20 Lockwasher
X 33.3mm
21 H101 48 Cap Screw
1.22 .59 22 K983 004 Shock Pad
7 2 4 3 31.0mm 56 15.0mm
* Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see Optional
Functions page. D
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve. For
E
alternate flow path usages, see Optional Functions page.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Mounting
IN U
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
N
Port A. “Cylinder” Port B is connected to “Exhaust” Port E. T Operation: Pressure Service
Pilot “A” pressurized last – Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port E.
O
When pressure to pilot is removed – Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is Pilot “B” pressurized last – Pressure at Port P is
connected to “Exhaust” Port E. connected to “Cylinder” Port A. “Cylinder” Port B is
D A
E
B
P
Pilot
Pilot A A
E
B
P
Pilot B
Valve Only Subbase Manifold (End & Bottom Ports) ▲ Port Size
Single Solenoid Double Solenoid (Side Ports) 2 Station 3 Station (NPT)
L444 21 102 L414 21 102 K022 097 K142 077 K142 076 1/4"
▲ - Manifolds include mounting hardware.
14
16 K323 027 Remote Cap
17 16 13 17 K333 013 Plug Cap
21 11 19 H175 12 Lockwasher
20 H100 59 Cap Screw
20
19 21 K983 001 Shock Pad
4.03
15 102.4mm * Standard Service Kit: K352 363
1.50
.97 38.1mm
24.6mm EXH IN
1.33
33.8mm
4 5 3 2 6 7 8 2.66
67.6mm
6.74
171.2mm Double Remote
3.00 See Manifold Section for
76.2mm
.56 .56 Manifold Dimensional Data
14.2mm 14.2mm
CYL A CYL B
1.09
27.7mm PILOT PILOT
2.19 A B
55.6mm
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap cylinders. A momentary pressure signal applied
activates the valve. When this signal is removed, the alternately to each of the pilot caps shifts the valve.
valve shifts. For alternate flow path usages, see Optional For alternate flow path usages, see Optional
Functions page. Functions page.
Mounting Mounting
These valves are designed for subbase or modular These valves are designed for subbase or modular
manifold mountings. Order from chart below. manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
A B A B
Pilot A Pilot B
EA P EB EA P EB
Model Selection
Valve Only Subbase Manifold ▲ Port Size
Single Remote Double Remote (Side Ports) (End & Bottom Ports) (NPT)
1.75
44.5mm
.62
15.7mm
.75
9 8 7 2 3 4 25 5 6 19.1mm
7.56
192.0mm Double Remote
2.94 3.32 See Manifold Section for
74.7mm 84.3mm Manifold Dimensional Data
.34 Dia
1.12 1.12 8.6mm
28.4mm 28.4mm 2 Holes
CND A B
1.44 1.34
36.6mm 34.0mm
PILOT PILOT
2.88 B A 2.84
73.2mm 71.1mm
EA P X EB
Parts List
.38 .75 Item
9.7mm 19.1mm Part No. Description
2.00 2.00 1/4 Pipe No.
50.8mm 50.8mm * 2 — O-Ring (Dynamic)
3.16
80.3mm 3 K453 028 Spacer
6.03
153.2mm 4 K463 012 End Spacer
5 K343 094 Spool
* 6 — Seal
14 * 8 — Gasket
11
13 10 10 H175 12 Lockwasher
8 20
11 H100 60 Cap Screw
19
23 *12 — Gasket
12 4.76 13 K323 027 Remote Cap
120.9mm
14 K333 013 Plug Cap
19 H175 12 Lockwasher
1.75
44.5mm 20 H100 69 Cap Screw
.62
15.7mm *21 — O-Ring (Static)
.75
4 2 21 3 5 6 19.1mm 23 K983 002 Shock Pad
* Standard Service Kit: K352 355
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap
activates the valve. When this signal is removed, the
valve shifts. For alternate flow path usages, see Optional
Functions page.
E
For alternate flow path usages, see Optional
Functions page. D
cylinders. A momentary pressure signal applied
alternately to each of the pilot caps shifts the valve.
Mounting
These valves are designed for subbase or modular
manifold mountings. Order from chart below.
Mounting
IN U
These valves are designed for subbase or modular
manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap – Port P is connected to “Cylinder”
Port A. “Cylinder” Port B is connected to “Exhaust”
Port EB.
N T Operation: Pressure Service
Pilot “A” pressurized last – Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
O
When pressure to pilot is removed – Pressure at Port P is
connected to “Cylinder” Port B. “Cylinder” Port A is
connected to “Exhaust” Port EA.
C
connected to “Exhaust” Port EA.
Pilot “B” pressurized last – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
D I S A B
Pilot A
A B
Pilot B
EA P EB EA P EB
8.62
218.9mm Parts List
2.69 4.18
Single Remote
68.3mm 106.2mm See Manifold Section for Item Part No. Description
.34 Dia. Manifold Dimensional Data No.
.88 2.31 8.6mm
22.4mm 58.7mm 2 Holes
2 K18R311137 Retaining Ring
CYL A
CYL B
3 K553 011 Spacer
1.56 1.44
39.6mm PILOT 36.6mm * 4 — O-Ring
3.25 3.00
82.6mm 76.2mm 5 K453 008 Spacer
6 K463 001 End Spacer
EXH IN EXH
7 K232 017 Spool Assy.
1.62 2.03
* 8 — Seal
41.1mm 1/4 Pipe
51.6mm *12 — Gasket
3.25
82.6mm 14 H175 12 Lockwasher
6.25
158.8mm 15 H100 60 Cap Screw
*16 — Gasket
18 15 17 K323 027 Remote Cap
17 25
12 14 18 K333 013 Plug Cap
24
23 H175 16 Lockwasher
23
4.88
24 H101 25 Cap Screw
124.0mm 25 K983 003 Shock Pad
16
* Standard Service Kit: K352 361
1.53
.84 38.9 mm
X
21.3mm
1.00 .50
25.4mm 12.7mm
9 8 2 3 7 45 6
8.07
205.0mm Double Remote
3.13 3.83
79.5mm 97.3mm .34 Dia. See Manifold Section for
1.31 1.88 8.6mm Manifold Dimensional Data
33.3mm 47.8mm 2 Holes
CYL A
CYL B
1.56 1.44
39.6mm PILOT PILOT 36.6mm
3.25 B A
3.00
82.6mm 76.2mm
EXH IN EXH
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap cylinders. A momentary pressure signal applied
activates the valve. When this signal is removed, the alternately to each of the pilot caps shifts the valve.
valve shifts. For alternate flow path usages, see Optional For alternate flow path usages, see Optional
Functions page. Functions page.
Mounting Mounting
These valves are designed for subbase or modular These valves are designed for subbase or modular
manifold mountings. Order from chart below. manifold mountings. Axis of main valve spool to be in
horizontal plane. Order from chart below.
Operation: Pressure Service
Pressure to pilot cap – Port P is connected to “Cylinder” Operation: Pressure Service
Port A. “Cylinder” Port B is connected to “Exhaust” Pilot “A” pressurized last – Pressure at Port P is
Port EB. connected to “Cylinder” Port B. “Cylinder” Port A is
When pressure to pilot is removed – Pressure at Port P is connected to “Exhaust” Port EA.
connected to “Cylinder” Port B. “Cylinder” Port A is Pilot “B” pressurized last – Pressure at Port P is
connected to “Exhaust” Port EA. connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port EB.
A B A B
Pilot A Pilot B
EA P EB EA P EB
1.22
31.0mm
.59
10 9 2 3 4 5 68 7 15.0mm
9.50
1/2-14 Pipe 31.0mm
Double Remote
Conduit 3.38 4.75
See Manifold Section for
Connection 85.8mm 120.6mm
1.53 1.53
Manifold Dimensional Data
38.9mm 38.9mm
CYL. A CYL. B
2.28 2.44
57.9mm 62.0mm
PILOT PILOT
B A 4.28
4.56 108.7mm
115.8mm
EXH EXH
Parts List
.39 Dia. Item
2.46 2.45 9.9mm Part No. Description
62.5mm 62.2mm 2 Holes No.
3.81
1/4 Pipe 96.8mm 2 K463 005 End Spacer
7.62 1/4 Pipe
193.5mm * 3 — O-Ring (Dynamic)
15 12 * 4 — O-Ring (Static)
14
9 22 11 5 K453 009 Spacer
6 K343 061 Spool
21 * 7 — Seal
20 * 9 — Gasket
6.57
166.9mm 11 H175 12 Lockwasher
13
12 H100 60 Cap Screw
*13 — Gasket
2.09
1.31 53.1mm 14 K323 027 Remote Cap
X 33.3mm
15 K333 013 Plug Cap
1.22 .59
7 2 4 3 31.0mm 56 15.0mm
20 H175 20 Lockwasher
21 H101 48 Cap Screw
22 K983 004 Shock Pad
* Standard Service Kit: K352 360
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4", 1/2" & 3/4" NPT Ports
Application Mounting
These valves may be used to actuate double acting These valves are designed for subbase or modular
cylinders, when “inching” or incremental rod movement is manifold mountings. Electrical connection from valve to
desired. A “momentary” (exceeding .03 seconds) or base is automatic. Air & electrical connections remain
maintained electrical signal applied to one of the undisturbed if valve is removed. Order from chart below.
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed. 1/4" Basic 1/2" Basic
Valve may be applied for alternate service. For alternate
flow path usages, see Optional Functions page. A B Sol B A B Sol A
Model Selection (Neutral “Class 21” Shown) Note: Shaded units are no longer available.
120V 60Hz
L425 29 211 53
110V 50Hz K022 097 K142 077 K142 076 — 1/4"
L425 23 211 ** Other
120V 60Hz
L525 59 211 53 K022 092 — — K142 233 1/2"
110V 50Hz
L525 53 211 ** Other K022 093 — — K142 234 3/4"
See page 4 & 5 for variations in class of neutral configuration and ( ▲ - Manifolds include mounting hardware.
**) voltage codes.
24 Parker Hannifin Corporation
Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog VAL-SK-E/USA Speed King SK-200 Series
Dimensional Data & Service Kits L425 & L525, 1/4" & 1/2" Basic Valve
11.11
282.2mm 1/2" Basic
3.13 5.56
1/2 Pipe 79.5mm 141.2mm See Manifold Section for
Conduit .34 Dia. Manifold Dimensional Data
Connection
1.31 1.88 8.6mm Parts List
33.3mm 47.8mm 2 Holes
Item
CYL A
CYL B Part No. Description
No.
1.44
36.6mm 2 K463 001 End Spacer
3.00 Wiring Diagram
SOL. B SOL. A
76.2mm * 3 — O-Ring
Sol. A Sol. B
(+) (–) (+) (–)
4 K453 008 Spacer
EXH IN EXH
Application Mounting
These valves may be used to actuate double acting These valves are designed for subbase or modular
cylinders, when “inching” or incremental rod movement manifold mountings. Electrical connection from valve to
is desired. A “momentary” (exceeding .03 seconds) or base is automatic. Air & electrical connections remain
maintained electrical signal applied to one of the undisturbed if valve is removed. Order from chart below.
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed. Operation: Pressure Service
Valve may be applied for alternate service. For alternate
Neutral “Class 21”
flow path usages, see Optional Functions page.
Both solenoids de-energized (Normal Condition) –
Sol B A B Sol A All ports blocked.
Neutral “Class 22”
Both solenoids de-energized (Normal Condition) –
“Cylinder” Port A is open to “Exhaust” Port EA, “Cylinder”
EA P EB Port B is open to “Exhaust” Port EB, “Pressure”
Port P is blocked.
Sol B Sol A
Neutral “Class 23”
A B
Both solenoids de-energized (Normal Condition) –
“Cylinder” Port A is open to Pressure Port P, “Cylinder”
Port B is open to Pressure Port P. Both “Exhaust”
Ports EA and EB are blocked.
EA P EB Activated Operation
With solenoid “A” energized – Pressure at Port P flows
Sol B A B Sol A
to “Cylinder” Port A, “Cylinder” Port B is connected to
“Exhaust” Port EB, regardless of neutral “class”.
With solenoid “B” energized – Pressure at Port P flows to
“Cylinder” Port B, “Cylinder” Port A is connected to
“Exhaust” Port EA, regardless of neutral “class”.
EA P EB
Model Selection (Neutral “Class 21” Shown) Note: Shaded units are no longer available.
See page 5 for variations in class of neutral configuration ▲ - Manifolds include mounting hardware, except for port adapters.
and ( ) voltage codes. See chart, order separately.
**
26 Parker Hannifin Corporation
Pneumatic Division
Pneumatic Richland, Michigan
www.parker.com/pneumatic
Catalog VAL-SK-E/USA Valvair II Series
Dimensional Data & Service Kits L665, 3/8" & 1" Basic Valve
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4", 1/2" & 3/4" NPT
Ports
Application Mounting
These valves may be used to actuate double acting These valves are designed for subbase or modular
cylinders when “inching” or incremental rod movement
is desired. A normally open pilot signal to both pilot caps
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate service. For alternate
manifold mountings. Order from chart below.
E D
U
flow path usages, see Optional Functions page. Neutral “Class 21”
Normally open pilot signals to both pilot caps –
All ports blocked.
IN
Neutral “Class 22”
Normally open pilot signals to both pilot caps – “Cylinder”
T
Port A is connected to “Exhaust” Port E (EA) and
“Cylinder” Port B is connected to “Exhaust” Port E (EB).
N
1/4" Basic 1/2" Basic Pressure at Port P is blocked.
A B
Neutral “Class 23”
Pilot B Pilot A Pilot B A B Pilot A
O
Normally open pilot signals to both pilot caps – “Cylinder”
Ports A and B are connected to Port P. “Exhaust” Port(s)
E (EA and EB) are blocked.
C
P E EA P EB
Activated Operation
S
Pilot B A B Pilot A Pilot B A B Pilot A
When Pilot “A” is exhausted – Pressure at Port P is
I
connected to “Cylinder” Port A. “Exhaust” Port E (EB) is
connected to “Cylinder” Port B.
D
E P EA P EB When Pilot “B” is exhausted – Pressure at Port P is
connected to “Cylinder” Port B, “Exhaust” Port E (EA) is
A B A B
connected to “Cylinder” Port A.
Pilot B Pilot A Pilot B Pilot A
E P EA P EB
11.11
282.2mm 1/2" Basic
3.13 5.56
1/2 Pipe 79.5mm 141.2mm See Manifold Section for
Conduit .34 Dia. Manifold Dimensional Data
1.31 1.88 8.6mm
Connection 33.3mm 47.8mm 2 Holes
CYL A
CYL B Parts List
1.44
36.6mm Item Part No. Description
3.00 No.
PILOT PILOT
B A 76.2mm
2 K463 001 End Spacer
EXH IN EXH * 3 — O-Ring
1/4 Pipe .44 1/4 Pipe 4 K453 008 Spacer
11.2mm
1.62
5 K343 045 Spool
2.03
41.1mm 51.6mm (All Ports Blocked)
3.25
82.6mm 5 K343 067 Spool (Cyl. Ports
6.25 Open to Inlet)
158.8mm
5 K343 068 Spool (Cyl. Ports
Open to Exh.)
15
13 17 * 6 — Seal
6 28
14 16 * 8 — Seal
26 9 K313 017 Piston
25
*10 — Seal
4.88
18 124.0mm 13 K323 027 Remote Cap
*14 — Gasket
1.53 15 K333 013 Plug Cap
.84 38.9mm
X
21.3mm 16 H175 12 Lockwasher
1.00 .50 1.56 17 H100 60 Cap Screw
25.4mm 12.7mm 39.6mm
3.25 *18 — Gasket
10 8 9 2 3 4 5
82.6mm
25 H175 16 Lockwasher
26 H101 25 Cap Screw
28 K983 003 Shock Pad
* Standard Service Kit: K352 358
EA P EB
Model Selection (Neutral “Class 21” Shown) Note: Shaded units are no longer available.
See page 5 for variations in class of neutral configurations. ▲ - Manifolds include mounting hardware.
9.64
244.8mm 3/8" Basic Parts List
2.94 4.82 See Manifold Section for Item Part No.
74.7mm 122.4mm Description
Manifold Dimensional Data No.
1.12 1.12 .34 Dia.
28.4mm 28.4mm 8.6mm
D * 2 — O-Ring (Dynamic)
2 Holes
CND A B
1.44 1.34 3 K453 028 Spacer
36.6mm PILOT PILOT 34.0mm
2.88 B A
2.84
4 K463 012 End Spacer
73.2mm 72.1mm
5 K343 124 Spool
(All Ports Blocked)
EA P X EB
5 K343 126 Spool (Cyl. Ports
1/4 Pipe
.38 .75 1/4 Pipe
Open to Inlet)
9.7mm 19.1mm
2.00 2.00 5 K343 125 Spool (Cyl. Ports
50.8mm 50.8mm
3.16
Open to Exh.)
80.3mm
6.03 * 6 — Seal
153.2mm
* 8 — Seal
9 K313 049 Piston
19 *10 — Seal
17 *14 — Gasket
15
16
29 15 K323 027 Remote Cap
14 26
25
16 H175 12 Lockwasher
4.76
120.9 mm 17 H100 60 Cap Screw
18
*18 — Gasket
25 H175 12 Lockwasher
1.75
.62
44.5mm 26 H100 69 Cap Screw
15.7mm
*27 — O-Ring (Static)
.75
6 9 10 8 6 4 5 3 27 2 19.1mm 28 K333 013 Plug Cap
13.62 29 K983 002 Shock Pad
345.9mm 1" Basic
3.38 6.81 See Manifold Section for * Standard Service Kit: K352 355
85.8mm 173.0mm Manifold Dimensional Data
1.53 1.53
38.9mm 38.9mm
CYL. A CYL. B
2.44 Parts List
62.0mm
4.56
PILOT
B
PILOT
A
4.28 Item Part No. Description
108.7mm
115.8mm No.
2 K463 005 End Spacer
EXH EXH
.39 Dia.
* 3 — O-Ring (Static)
9.9mm
1/4 Pipe 2.46 2.45 2 Holes * 4 — O-Ring (Dynamic)
62.5mm 62.2mm
3.81 1/4 Pipe 5 K453 009 Spacer
96.8mm
7.62 6 K343 060 Spool
193.5mm
(All Ports Blocked)
6 K343 070 Spool (Cyl. Ports
28 Open to Exh.)
18
14 17 6 K343 069 Spool (Cyl. Ports
15 29
Open to Inlet)
27
* 7 — Seal
26 * 9 — Seal
6.57
166.8mm 10 K313 023 Piston
19 *11 — Seal
2.09 14 K323 027 Remote Cap
1.31 53.1mm
X 33.3mm *15 — Gasket
1.22 .59 17 H175 12 Lockwasher
11 9 10 2 3 4 31.0mm 56 7 15.0mm
18 H100 60 Cap Screw
*19 — Gasket
26 H175 20 Lockwasher
27 H101 48 Cap Screw
28 K333 013 Plug Cap
29 K983 004 Shock Pad
* Standard Service Kit: K352 360
1. Factory assembly instructions – valve & manifold (or subbase) to be assembled. Sequence of
assembly to be as listed on order (see example) from left to right when facing end cylinder ports.
3. Number of stations:
00 = Single Subbase
01 = Single (Modular) Manifold (Do not use with 1/4" Basic Size)
02 = 2-Station
¬ ¬
* 12 = 12-Station
* More stations may be added, if there is sufficient upstream volume and pressure to insure that the last valve in the
assembly will function. An increased upstream volume, conversion to an external pilot, or an additional inlet may
prevent “starvation” problems on larger assemblies.
1. Number of Stations
2. Valve Size
3. Factory Assembly
6.38
162.1mm
1.81 2.50
46.0mm 63.5mm
1.00 1.00
25.4mm 25.4mm
CYL. B CYL. B
CYL. A CYL. A
.50
12.7mm
D
4.40
111.8mm
Dbl. Plug-In Manifold
Sol.
E
4.30
109.2mm
EXH
2.22 Sing.
56.4mm Sol.
U
INLET
IN
5.56
141.2mm
Cylinder Ports ................................................... 1/4" NPTF
CONDUIT
T
LEFT RIGHT
Exhaust Port ..................................................... 1/2" NPTF
Inlet Port ........................................................... 1/2" NPTF
N
.41 Dia. Conduit Port .................................................. 1-1/4" NPTF
10.4mm
2 Holes
4.50
O
114.3mm
K142-077 Two-Station Manifold
C
9.19
233.4mm
1.81 1.81 2.50
S
46.0mm 46.0mm 63.5mm
I
1.00 1.00 1.00
25.4mm 25.4mm 25.4mm 2.00
1/4 N.P.T.F. 50.8mm
CYL. B CYL. B CYL. B
D
CYL. A 1.25
CYL. A CYL. A 31.8mm
.84
.50 21.3mm
12.7mm
4.40
.50 111.8mm
12.7mm Dbl.
Sol.
4.30
109.2mm
EXH
2.22 Sing.
56.4mm Sol. 2.06
1.25 52.3mm 7.38
31.8mm 187.4mm
INLET
6.62
5.56 168.1mm
141.2mm 1.75
44.4mm
3.47
CONDUIT
88.1mm
LEFT CENTER RIGHT
8.05
204.5mm
.39 Dia.
9.9mm
2 Holes
2.56 .75
1.41
2.09 65.0mm 2.06 35.8mm19.1mm
1.09
27.7mm 1.81
53.1mm (Flange
Height) 52.3mm 46.0mm
.61
.75 1.66 .59 Bottom 15.5mm
19.1mm 42.2mm 15.0mm Cyl. 1/4
Typ. For Ports 3.19 1.19
81.0mm 30.2mm Pipe
Bottom Ports
.34 5.00 1.91
8.6mm 127.0mm 48.5mm
8.44
214.5mm
1/2" Basic 8.00
203.2mm
4.78
K142 233 Cyl. Ports 1/2" NPTF 121.4mm
K142 234 Cyl. Ports 3/4" NPTF CYL B
8.26
210.0mm
.39 Dia.
9.9mm
2 Holes
3.03
1.41 .75
2.09 77.0mm
(Flange 35.7mm 19.1mm
53.1mm Height)
1" Basic
K142 235 Cyl. Ports 3/4" NPTF
K142 236 Cyl. Ports 1" NPTF
K142 237 Cyl. Ports 1-1/4" NPTF
K122 016 End Plate Kit (Both Plates)
Exhaust Port ........................ 1-1/2" NPTF (Port Plate)
Inlet Port .............................. 1-1/2" NPTF (Port Plate)
Conduit Port ......................... 1-1/4" NPTF (Port Plate)
11.72
297.7mm
6.21
157.7mm
.406 Dia.
10.3mm
2 Holes P
EB EA X
A
1.19
30.2mm 4.88
124mm 5.69
144.5mm
2.44
B 62.0mm
Pipe Adaptor
(End Valves Only)
6.28
159.5mm
5.71 (Sing Sol)
145.0mm
.12 4.75 (Dbl Sol)
3.0mm 120.6mm
1.75 1.75
44.4mm 44.4 mm
3.03 4.25
77.0mm 108.0mm 2.85
1.53 72.4 mm
38.9mm 2.00 2.00
50.8mm 50.8 mm
2.50 2.50
63.5mm 63.5mm 1.28
.39 Dia. 32.5 mm
4.81 3.34 9.9mm
122.2mm 84.8mm 4 Holes 1.22
5.31 4.38 31.0 mm
134.9mm 111.2mm Bottom 2.44
Cyl. Ports 62.0 mm Typ. For
10.62 Bottom Ports
269.9mm
6.03
153.2mm
12.06
.25 306.4mm
6.4mm 6.41
162.8mm
12.81
325.4mm
3-Configurations
1. Common Port Regulation - A common regulated
pressure is selected to both cylinder ports.
2. Single Port Regulation - Line pressure is available to
one cylinder port, while a single regulated pressure is
selected to the other cylinder port.
3. Independent Port Regulation - Two independently
regulated pressures selected to the cylinder ports.
Regulator
NOTE: When using single or independent port sandwich Assembly
regulators, be aware that:
1. Cylinder port outlets are reversed.
2. 3-Position, cylinder ports open to exhaust and cylinder
ports open to inlet functions are reversed. To produce
a cylinder ports open to exhaust function, order valve
with cylinder ports open to inlet. To produce a cylinder
ports open to inlet function, order valve with cylinder
ports open to exhaust.
Typical Assembly
90 ➤
SECONDARY PRESSURE - bar
6 ➤
80 ➤
➤
5 70 ➤
➤
➤
60 ➤
4 ➤ ➤
50 ➤
➤
3 ➤
40 ➤
➤ ➤
2 30
➤
20
1
➤
10 ➤
0 0
10 0 10 20 30 40 50 60 70 80 90 100 110 120 130
FLOW - SCFM
5 0 5 10 15 20 25 30 35 40 45 50 55 60
FLOW - dm3/S
n
Function
This modular air pressure regulator assembly, installed
between a 3/8" basic, 4-Way valve and subbase, supplies
regulated pressures to both cylinder ports.
Valve must be converted to external pilot supply.
Features
Regulated pressure output from the valve is adjusted
by knob on the manually set model or by air pressure
signal applied to the regulator pilot port on the remotely
set model.
Furnished with pressure gauge as standard.
Assembly “A” (Shown at right) or Assembly “B” may be
specified as a matter of convenience, or to satisfy space
limitations.*
How To Order EX EX
1. Select type of adjustment
2. Select pressure range
3. Select assembly style
Pressure
Pressure Range Model Number
Adjustment
psi Assembly “A” Assembly “B”
1 - 30 L554 01 308C L554 08 301C
Manual 1 - 60 L554 02 308C L554 08 302C
2 - 125 L554 03 308C L554 08 303C
Manual with 1 - 30 L554 27 308C L554 08 327C
Liquid Filled 1 - 60 L554 28 308C L554 08 328C
Gauges 2 - 125 L554 29 308C L554 08 329C
Remote 0 - 140 L554 11 308C L554 08 311C
Remote with
Liquid Filled 0 - 140 L554 35 308C L554 08 335C
Gauges
Function
This modular air pressure regulator assembly, when installed
between a 3/8" basic, 4-Way valve and subbase or modular
manifold, supplies one or more regulated pressures to one of the
valve cylinder ports and supply pressure to the other cylinder
port.
On Single Port Cylinder Port Regulation Units controlled by a
single solenoid valve, cylinder port “B” is the normally open
cylinder port. The solenoid is energized to open cylinder Port “A”.
On double solenoid operated valves, energizing solenoid “B”
opens cylinder port “A” and energizing solenoid “A” opens
cylinder port “B”.
Features
Regulated pressure output from the valve is adjusted by knob on
the manually set model or by air pressure signal applied to the
regulator pilot port on the remotely set model.
Assembly “A”
For reduced pressure at “A” cylinder port, the regulator is
mounted per assembly “A” on end opposite the electrical junction
box. For reduced pressure at “B” cylinder port the regulator is Graphic Symbol
mounted per Assembly “B” which places the regulator over the
electrical junction box.
A B A B
Function
This modular air pressure regulation assembly, when
installed between a 3/8" basic, 4-Way valve and subbase
or modular manifold, supplies one or more regulated
pressures to each of the valve cylinder ports.
Regulated pressure to cylinder port “A”, and a second
regulated pressure to cylinder port “B”; independently
adjustable.
On Independent Cylinder Port Regulation Units controlled
by a single solenoid valve, cylinder port “B” is the
normally open cylinder port. The solenoid is energized to
open cylinder port “A”. On double solenoid operated
valves, energizing solenoid “B” opens cylinder port “A”
and energizing solenoid “A” opens cylinder port “B”
Valve must be converted to external pilot supply.
Features
Regulated pressure output from the valve is adjusted by
knob on the manually set model or by air pressure signal
applied to the regulator pilot port on the remotely set Graphic Symbol
model. A B
How To Order
1. Select type of adjustment
2. Select pressure range for each
cylinder port Cylinder Model Number
Pressure Port “A” Cylinder Port “B”
Adjustment
Example: Manual adjusted. psi 5-30 5-60 10-125†
5-60 psi range for cylinder port “A” 1 -30 L554 04 304C L554 04 305C L554 04 306C
and 10-125 psi for cylinder port “B” Manual 1 - 60 L554 05 304C L554 05 305C L554 05 306C
Model No. L554 06 305C
2 - 125 L554 06 304C L554 06 305C L554 06 306C
NOTE: When using single or independent port Manual with 1 - 30 L554 30 330C L554 30 331C L554 30 332C
sandwich regulators, be aware that: Liquid Filled 1 - 60 L554 31 330C L554 31 331C L554 31 332C
1. Cylinder port outlets are reversed. Gauges 2 - 125 L554 32 330C L554 32 331C L554 32 332C
2. 3-Position, cylinder ports open to exhaust
and cylinder ports open to inlet functions are Remote 0 - 140 — — L554 14 314C†
reversed. To produce a cylinder ports open to Remote with
exhaust function, order valve with cylinder Liquid Filled 0 - 140 — — L554 38 338C†
ports open to inlet. To produce a cylinder Gauges
ports open to inlet function, order valve with
cylinder ports open to exhaust. Note: Shaded units are no longer available.
†
Remote operator units 0-140 PSI
FF
GG
* Assembly “A” places the
regulator on the end opposite
the electrical junction box. DD EE
Assembly “B” places the CC
regulator over the electrical
junction box. A
KK KK
JJ REMOTE JJ REMOTE
V
U
T
A* B*
1/4" PIPE
E PORT
P E
MM
E P
LL
Z
A G H R
D F S
Y DIA. AA
C (2 HOLES) O 1/4 Pipe
W P
B BB
N
BOTTOM CYL. PORTS BOTTOM CYL. J Q
LOCATED HERE PORTS X K 1/8 Pipe
L 1/4 Pipe
M
A B C D E F G H J K L M N
inches 2.56 .75 1.50 2.09 11.28 2.06 1.41 .75 .34 5.00 8.44 9.09 3.19
mm 65.0 19.1 38.1 53.1 286.5 52.3 35.8 19.1 8.64 127.0 214.4 230.9 81.0
O P Q R S T U V W X Y Z AA
inches .61 1.19 1.91 1.09 1.81 3.32 6.64 7.56 3/8", 1/2" or .39 1" 1"
mm 15.5 30.2 48.5 27.7 46.0 84.3 168.7 192.0 3/4" NPTF 9.9 NPTF NPTF
BB CC DD EE FF GG HH JJ KK LL MM
inches 1-1/4" 3.00 1.50 1.24 7.97 4.34 .40 8.53 10.15 5.46 8.80
mm NPTF 76.2 38.1 31.5 202.4 110.2 10.2 216.6 257.8 138.6 223.5
Table ‘D’
Remote End Section
12 10 1 3 2 17 7 14 13 Single Independent Port
Regulation
Independent Port Regulation
End Section Assemblies: See Tables ‘C’ or ‘D’ psi Standard Liquid Filled
Parts: See Table ‘E’ 0-140 K362 314C K362 338C
4 6 7 8 18 8 7 6 15
5 5
12 10 1 3 2 10 12
Replacement Gauges
7
psi Standard Liquid Filled
0-60 3560 0400 H032 57
0-160 3560 0410 H032 58
0-300 3560 0420 —
13 2 3 4 5 6
EXH EXH
P P
BA BA BA BA
REMOTE
AIR
SIGNAL
Pressure Exhaust
L 48 5 2 9 10 2 53 —
Type Operator Size Duty Cycle Lead Length
46 Double 4 Remote 2 1/4" NPT Inlet 2 Standard Service Blank 19"
48 Single 5 Solenoid & Cyl. 3/8" Solenoid or Remote (Standard)
NPT Exh. 4 Continuous Service L 72"
3 3/8" NPT Inlet, Solenoid (Optional)
Operator Options
Cyl. & Exh.
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override Enclosure “Class” Voltage & Frequency
3 Solenoid w/Locking Override 10 Standard (NEMA 1 & 12) 60Hz 50Hz DC
4 Solenoid w/Jct. Box or Remote
5 Solenoid w/Jct. Box & Non-Locking Override 45 12
60 Hazardous Duty
6 Solenoid w/Jct. Box & Locking Override (NEMA 7 & 9) ■ * 49 24
7 Solenoid w/Jct. Box & Light
80 NEMA 4 ■ 53 120 110
(120VAC, 24VDC)
8 Solenoid w/Jct. Box & Light ■ Use with operator options 57 240 220
(120VAC, 24VDC) & Non-Locking Override 1 & 3 only.
9 Solenoid w/Jct. Box & Light * Voltage 49 / 53 only.
(120VAC, 24VDC) & Locking Override
L 70 5 3 9 10 2 53 L
Type Operator Size Duty Cycle Lead Length
68 Double 4 Remote 3 3/8" NPT Inlet & 2 Standard Service Blank 19"
70 Single 5 Solenoid Cyl. 1/2" NPT Exh. Solenoid or Remote (Standard)
4 1/2" NPT Inlet, Cyl. 4 Continuous Service L 72"
& Exh. Solenoid (Optional)
Operator Options 7 3/4" NPT Inlet &
1 Solenoid (Basic) or Remote Cyl. 1" NPT Exh.
2 Solenoid w/Non-Locking Override Enclosure “Class” Voltage & Frequency
8 1" NPT Inlet & Cyl.
3 Solenoid w/Locking Override 1-1/4" NPT Exh. 10 Standard (NEMA 1 & 12) 60Hz 50Hz DC
4 Solenoid w/Jct. Box 9 1-1/4" NPT Inlet or Remote 45 12
5 Solenoid w/Jct. Box & Non-Locking Override Cyl. & Exh. * 60 Hazardous Duty
6 Solenoid w/Jct. Box & Locking Override (NEMA 7 & 9) ■ * 49 24
7 Solenoid w/Jct. Box & Light (120VAC, 24VDC) * Not available operator
80 NEMA 4 ■ ** 53 120 110
8 Solenoid w/Jct. Box & Light option 4 - Remote Pilot.
(120VAC, 24VDC) & Non-Locking Override ■ Use with operator options 57 240 220
9 Solenoid w/Jct. Box & Light 1 & 3 only.
(120VAC, 24VDC) & Locking Override * Voltage 49 / 53 only.
** Voltage 53 only
L 64 5 5 9 10 2 53 —
Operator
4 Remote
5 Solenoid Duty Cycle Lead Length
2 Standard Service Solenoid Blank 19" (Standard)
or Remote L 72" (Optional)
4 Continuous Service
Solenoid
Operator Options
1 Solenoid (Basic) or Remote
2 Solenoid w/Non-Locking Override
3 Solenoid w/Locking Override
4 Solenoid w/Jct. Box
5 Solenoid w/Jct. Box & Non-Locking Override
6 Solenoid w/Jct. Box & Locking Override
7 Solenoid w/Jct. Box & Light
(120VAC, 24VDC)
8 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Non-Locking Override
9 Solenoid w/Jct. Box & Light
(120VAC, 24VDC) & Locking Override
L 47 5 2 9 21 1 53 —
L 69 5 3 9 21 1 53 —
L 62 5 5 9 21 1 53 —
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, see valve. It will remain in this position until a “momentary”
Optional Functions page. signal is applied to the other solenoid. For alternative flow
path usages, service, see Optional Functions page.
Mounting
Valve may be mounted in any position. Mounting
Axis of main valve spool to be in horizontal plane.
Operation: Pressure Service
De-energized (normal condition) – Pressure at Port P is Operation: Pressure Service
connected to “Cylinder” Port A. “Cylinder” Port B is With solenoid “A” having been energized last – Pressure
connected to “Exhaust” Port E. at Port P is connected to “Cylinder” Port A. “Cylinder” Port
Energized (maintained signal applied) – Pressure at B is connected to “Exhaust” Port E.
Port P is connected to “Cylinder” Port B, “Cylinder” Port A Energize solenoid “B” – Pressure at Port P is connected
is connected to “Exhaust” Port E. to “Cylinder” Port B. “Cylinder” Port A is connected to
“Exhaust” Port E.
A B
Sol A A B Sol B
P E
P E
Model Selection
Valve Port Size (NPT) Operator
Voltage
Single Solenoid Double Solenoid P, A & B Exhaust Type
L485 29 102 53 L465 29 102 53 120V 60Hz 1/4" 3/8" Junction
L485 39 102 53 L465 39 102 53 110V 50Hz 3/8" 3/8" Box
L485 26 102 ** L465 26 102 ** 1/4" 3/8" Junction
Other
L485 36 102 ** L465 36 102 ** 3/8" 3/8" Box
L485 23 102 ** L465 23 102 ** 1/4" 3/8"
Any Basic
L485 33 102 ** L465 33 102 ** 3/8" 3/8"
L485 23 802 ** L465 23 802 ** 1/4" 3/8"
Any NEMA 4
L485 33 802 ** L465 33 802 ** 3/8" 3/8"
L485 23 602 ** L465 23 602 ** See Voltage 1/4" 3/8" ▲ Hazardous
L485 33 602 ** L465 33 602 ** Chart 3/8" 3/8" Duty
See page 45 for variations and ( ) voltage codes. ▲ - UL & CSA Approved.
**
Note: Shaded areas are no longer available.
.81 .33
20.6mm 8.4mm
21 7 5 4 3 2 6 8
6.74
171.2mm
3.00
Double Solenoid
76.2mm
1.00 1.00
1.82 25.4mm 25.4mm
46.2mm A EXH
TYP. X B
l. B 1.50
1.17 So
29.7mm 38.1mm
2.34 2.75
59.4mm 33 69.8mm
Typ.
l. A
So
1.50
38.1mm
TYP. IN .27 Dia.
6.8mm
1.84 2 Holes
46.7mm
4.47
113.5mm
1/2 Pipe
17 Conduit
Connection Parts List
11
Item
10 Part No. Description
No.
* 2 — O-Ring
3 K453 005 Spacer
8 3.31 4 K493 005 Spool
84.1mm
4.73 * 5 — Seal
120.1mm
* 8 — Gasket
10 H175 12 Lockwasher
.81 .33
20.6mm 8.4mm 11 H100 60 Cap Screw
See Wiring Instructions, page 85,
for units with flying leads. 2 3 4 5 18 17 K152 003 Override Assy.
18 K983 001 Shock Pad
* Standard Service Kit: K352 151
* Special Service Kit: K352 351
(Continuous Duty)
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, such as valve. It will remain in this position until a “momentary”
dual pressure service, see Optional Functions page. signal is applied to the other solenoid. For alternative flow
path usages, such as dual pressure service, see Optional
Mounting Functions page.
Valve may be mounted in any position.
Mounting
Operation: Pressure Service Axis of main valve spool to be in horizontal plane.
De-energized (normal condition) – Pressure at Port P is
connected to “Cylinder” Port A. “Cylinder” Port B is
Operation: Pressure Service
connected to “Exhaust” Port EB. With solenoid “A” (solenoid nearest Port B on valve body)
having been energized last – Pressure at Port P is
Energized (maintained signal applied) – Pressure at
connected to “Cylinder” Port A. “Cylinder” Port B is
Port P is connected to “Cylinder” Port B, “Cylinder” Port A
connected to “Exhaust” Port EB.
is connected to “Exhaust” Port EA.
Energize solenoid “B” (solenoid nearest Port A on valve
A B body) – Pressure at Port P is connected to “Cylinder”
Port B. “Cylinder” Port A is connected to “Exhaust”
Port EA.
Sol B A B Sol A
EA P EB
Model Selection EA P EB
Valve Port Size (NPT) Operator
Voltage
Single Solenoid Double Solenoid P, A & B EA & EB Type
L705 39 102 53 L685 39 102 53 120V 60Hz 3/8" 1/2" Junction
L705 49 102 53 L685 49 102 53 110V 50Hz 1/2" 1/2" Box
L705 36 102 ** L685 36 102 ** 3/8" 1/2" Junction
Other
L705 46 102 ** L685 46 102 ** 1/2" 1/2" Box
L705 33 102 ** L685 33 102 ** 3/8" 1/2"
Any Basic
L705 43 102 ** L685 43 102 ** 1/2" 1/2"
L705 33 802 ** L685 33 802 ** 3/8" 1/2"
Any NEMA 4
L705 43 802 ** L685 43 802 ** 1/2" 1/2"
L705 33 602 ** L685 33 602 ** See Voltage 3/8" 1/2" ▲ Hazardous
L705 43 602 ** L685 43 602 ** Chart 1/2" 1/2" Duty
See page 45 for variations and ( ▲ - UL & CSA Approved.
**) voltage codes.
6 .64
168.7mm
3.32
84.3mm
.90 .90
Double Solenoid
1.82 22.9mm 22.9mm
46.2mm
TYP. A X B
33
Typ. l. A
So
2.56
65.0mm
1.28
l. B 32.5mm
So
1.50
38.1mm EA P EB
TYP. .27 Dia.
1.33 1.33 6.8mm
33.8mm 33.8mm 2 Holes
1.66 2.34
42.2mm 54.9mm
TYP.
4.69 1/2 Pipe
119.1mm Conduit
11 Connection
10 Parts List
Item Part No. Description
No.
* 2 — O-Ring (Dynamic)
5.35 3 K453 028 Spacer
135.9mm
4 K463 012 End Spacer
3.91
8 99.3mm 5 K343 094 Spool
23
* 6 — Seal
.94 .53
23.9mm 13.5mm * 8 — Gasket
1.62 10 H175 12 Lockwasher
.38 41.1mm
9.7mm 3.25 11 H100 60 Cap Screw
4 18 21 2 3 5 6 82.6mm
See Wiring Instructions, page 85, 18 K152 003 Override Assy.
for units with flying leads *21 — O-Ring (Static)
23 K983 002 Shock Pad
* Standard Service Kit: K352 126
* Special Service Kit: K352 127
(Continuous Duty)
EA P EB
Model Selection EA P EB
8.62
218.9mm Parts List
3.83 Single Solenoid
97.3mm Item Part No. Description
1.41 1.41 No.
35.8mm 35.8mm
A X B 2 K18R311137 Retaining Ring
1.38
3 K553 011 Washer
35.1mm * 4 — O-Ring
2.75
69.8mm 5 K453 008 Spacer
6 K463 001 End Spacer
EA P EB
7 K232 017 Spool Assy.
1.77 1.77 * 8 — Seal
45.0mm 45.0mm
.35 2.60
8.9mm 66.0mm * 9 — Seal
5.20
132.1mm *12 — Gasket
1.50 14 H175 12 Lockwasher
1/2 Pipe 38.1mm
Conduit
Connection 15 H100 60 Cap Screw
22 22 K152 003 Override Assy.
25 K983 003 Shock Pad
15
25 5.52 14
* Standard Service Kit: K352 152
140.2mm * Special Service Kit: K352 352
12
4.09 (Continuous Duty)
103.9mm
1.06 .20
26.9mm 5.1mm
1.84
.49 46.7mm
12.4mm
9 8 2 3 7 4 5 6 3.69
93.7mm
7.66
194.6mm Double Solenoid
3.83
97.3mm
1.41 1.41
1.82 35.8mm 35.8mm
46.2mm
Typ. A X B
l. A
So
1.38
35.1 mm
2.75
33 69.8mm
Typ.
l. B
So
1.50
38.1mm EA P EB
1.77 1.77
45.0mm 45.0mm
.35 2.60
8.9mm 66.0mm
5.20 1/2 Pipe
132.1mm Conduit
Connection
18
Parts List
Item
Part No. Description
No.
11 2 K463 001 End Spacer
5.52 10 * 3 — O-Ring
140.2mm 8
4 K453 008 Spacer
4.09
103.9mm 5 K343 046 Spool
1.06 * 6 — Seal
26.9mm .20
5.1mm * 8 — Gasket
1.84 10 H175 12 Lockwasher
.49 46.7mm
6 3 5 4 2 21 12.4mm 3.69 11 H100 60 Cap Screw
93.7mm
18 K152 003 Override Assy.
See Wiring Instructions, page 85,
for units with flying leads. 21 K983 003 Shock Pad
* Standard Service Kit: K352 153
* Special Service Kit: K352 353
(Continuous Duty)
Application Application
These valves may be used to actuate a double acting These valves may be used to actuate double acting
cylinder. A maintained electrical signal shifts the valve. cylinders. A “momentary” electrical signal (exceeding
When this signal is removed the valve returns to its .03 seconds) applied to one of the solenoids shifts the
normal condition. For alternate flow path usages, such as valve. It will remain in this position until a “momentary”
dual pressure service, see Optional Functions page. signal is applied to the other solenoid. For alternative
flow path usages, such as dual pressure service, see
Mounting Optional Functions page.
Valve may be mounted in any position. Mounting
Operation: Pressure Service Axis of main valve spool to be in horizontal plane.
De-energized (normal condition) – Pressure at Port P is Operation: Pressure Service
connected to “Cylinder” Port A. “Cylinder” Port B is
With solenoid “A” (solenoid nearest Port B on valve
connected to “Exhaust” Port EB.
body) having been energized last – Pressure at Port P
Energized (maintained signal applied) – Pressure at Port is connected to “Cylinder” Port A. “Cylinder” Port B is
P is connected to “Cylinder” Port B, “Cylinder” Port A is connected to “Exhaust” Port EB.
connected to “Exhaust” Port EA.
Energize solenoid “B” (solenoid nearest Port A on
valve body) – Pressure at Port P is connected to
A B “Cylinder” Port B. “Cylinder” Port A is connected to
“Exhaust” Port EA.
Sol B A B Sol A
EA P EB
Model Selection EA P EB
Valve Port Size (NPT)
Voltage Type
Single Solenoid Double Solenoid P, A & B EA & EB
L705 79 102 53 L685 79 102 53 3/4" 1"
Junction
L705 89 102 53 L685 89 102 53 1" 1-1/4"
110V 50Hz Box
L705 99 102 53 L685 99 102 53 1-1/4" 1-1/4"
L705 76 102 ** L685 76 102 ** 3/4" 1"
Junction
L705 86 102 ** L685 86 102 ** Other 1" 1-1/4"
Box
L705 96 102 ** L685 96 102 ** 1-1/4" 1-1/4"
L705 73 602 ** L685 73 602 ** 3/4" 1"
See Voltage ▲ Hazardous
L705 83 602 ** L685 83 602 ** 1" 1-1/4"
Chart Duty
L705 93 602 L685 93 602 1-1/4" 1-1/4"
** **
See page 45 for variations and ( ) voltage codes. ▲ - UL & CSA Approved.
**
Parts List
10.46
265.7mm Item Part No. Description
4.75
Single Solenoid No.
120.6mm
1.62 1.62 2 H090 09 Retaining Ring
41.1mm 41.1mm
A X B
3 K553 009 Spacer
* 4 — O-Ring (Dynamic)
* 5 — O-Ring (Static)
4.25 6 K453 009 Spacer
108.0mm
7 K463 005 End Spacer
2.12 8 K232 014 Spool Assy.
53.8mm
* 9 — O-Ring
EA P EB
*10 — Seal
.41 Dia.
2.19 2.19 10.4mm
55.6mm 55.6mm 2 Holes
*13 — Gasket
3.44
87.4mm 15 H175 12 Lockwasher
7.44
189.0mm 16 H100 60 Cap Screw
1.50
1.82 1/2 Pipe 38.1mm 23 K152 003 Override Assy.
46.2mm Conduit
Connection 26 K983 004 Shock Pad
1.50 .20
38.1mm 5.1mm
2.62
.69 66.5mm
10 9 2 34 56 8 7 17.5mm 5.25
133.4mm
9.50
241.3mm 4.75 Double Solenoid
120.6mm
1.62 1.62
41.1mm 41.1mm
1.82 A
46.2mm X B
l. A
So
4.25
33 108.0mm
Typ.
l. B 2.12
So
53.8mm
1.50
38.1mm
EA P EB
.41 Dia.
2.19 2.19 10.4mm
55.6mm 55.6mm 2 Holes
3.44 Parts List
87.4mm
7.44 1/2 Pipe Conduit
189.0mm Connection Item Part No. Description
12 No.
11
19 2 K463 005 End Spacer
* 3 — O-Ring (Dynamic)
* 4 — O-Ring (Static)
6.44
163.6mm 5 K453 009 Spacer
9 4.95
125.7mm
6 K343 061 Spool
* 7 — Seal
.20 * 9 — Gasket
5.1mm
11 H175 12 Lockwasher
1.50 2.62
38.1mm 12 H100 60 Cap Screw
66.5mm
.69 5.25 19 K152 003 Override Assy.
22 17.5mm 133.4mm
2 4 3 5 6 7
22 K983 004 Shock Pad
See Wiring Instructions, page 85,
for units with flying leads. * Standard Service Kit: K352 130
* Special Service Kit: K352 131
(Continuous Duty)
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
D
cylinders. A maintained pressure signal to the pilot cap cylinders. A momentary pressure signal applied
activates the valve. When this signal is removed, the alternately to each of the pilot caps shifts the valve.
E
valve shifts. For alternate flow path usages, see For alternate flow path usages, see Optional
Optional Functions page. Functions page.
Mounting
Valve may be mounted in any position.
IN U
Axis of main valve spool to be in horizontal plane.
O
connected to “Exhaust” Port E. connected to “Cylinder” Port A. “Cylinder” Port B is
connected to “Exhaust” Port E.
I S C
D
A B Pilot A A B Pilot B
Pilot
E P E P
1.50
3 K453 006 Spacer
1.17 38.1mm
29.7mm PILOT * 4 — O-Ring
2.34 2.75
59.4mm 69.8mm 5 K453 005 Spacer
IN
* 6 — Seal
7 K232 018 Spool Assy.
1.84 2.36 * 8 — Seal
46.7mm 59.9mm 1/4 Pipe
4.47 9 K323 027 Remote Cap
113.5mm
*10 — Gasket
11 H175 12 Lockwasher
12 H100 60 Cap Screw
12 13 K983 001 Shock Pad
11 9
10 * Standard Service Kit: K352 363
2.56
65.0mm
.81
20.6mm
.33
8.4mm
13 74 5 3 2 6 8
6.74
171.2mm Double Remote
3.00
76.2mm
1.00 1.00
25.4mm 25.4mm 1/4 Pipe
A EXH B
1.17 1.50
29.7mm PILOT 38.1mm 2.75
A 69.8mm
2.34
59.4mm
.22
PILOT .22
5.6mm
B 5.6mm
IN
Parts List
7
Item
8
6
Part No. Description
No.
9
2.56 * 2 — O-Ring
65.0mm
3 K453 005 Spacer
.81
20.6mm 4 K493 005 Spool
.33
* 5 — Seal
8.4mm 6 K323 027 Remote Cap
10 2 3 4 5
7 H100 60 Cap Screw
8 H175 12 Lockwasher
* 9 — Gasket
10 K983 001 Shock Pad
* Standard Service Kit: K352 357
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap cylinders. A momentary pressure signal applied
activates the valve. When this signal is removed, the alternately to each of the pilot caps shifts the valve.
valve shifts. For alternate flow path usages, see Optional For alternate flow path usages, see Optional
Functions page. Functions page.
Mounting Mounting
Valve may be mounted in any position. Axis of main valve spool to be in horizontal plane.
A B A B
Pilot A Pilot B
EA P EB EA P EB
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B EA & EB
L704 31 102 L684 31 102 3/8" 1/2"
L704 41 102 L684 41 102 1/2" 1/2"
Pilot
* 4 — O-Ring (Dynamic)
2.56 5 K453 028 Spacer
65.0mm
1.28
32.5mm 6 K463 012 End Spacer
EA P EB 7 K232 020 Spool Assy.
1/4 Pipe 1.33 1.33 * 8 — Seal
33.8mm 33.8mm .27 Dia.
6.9mm
2.34 2 Holes * 9 — Seal
59.4mm
4.69 *10 — O-Ring (Static)
119.1mm
11 K323 027 Remote Cap
*12 — Gasket
13 H175 12 Lockwasher
14 H100 60 Cap Screw
15 K983 002 Shock Pad
14
11 13 * Standard Service Kit: K352 362
12
3.18
80.8mm
.94 .53
23.9mm 13.5mm
1.62
.38 41.1mm
9 8 72 3 4 10 5 6 15 9.7mm 3.25
82.6mm
6.64
80.8mm
3.32
84.3mm Double Remote
1.98 1.98
50.3mm 50.3mm
.90 .90
22.9mm 22.9mm 1/4 Pipe
A X B
.22
Pilot
Pilot 5.6mm
B
A
2.56
65.0mm
.22 1.28
5.6mm 32.5mm
EA P EB
Parts List
Item Part No. Description
No.
11 * 2 — O-Ring (Static)
10
9 3 K453 028 Spacer
8 13 4 K463 012 End Spacer
3.05
77.5mm
5 K343 094 Spool
.94 * 6 — Seal
23.9mm .53
13.5mm * 8 — Gasket
1.62 9 K323 027 Remote Cap
.38 41.1mm
4 12 2 3 5 6 9.7mm 3.25 10 H175 12 Lockwasher
82.6mm
11 H100 60 Cap Screw
*12 — O-Ring (Dynamic)
13 K983 002 Shock Pad
* Standard Service Kit: K352 355
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
D
cylinders. A maintained pressure signal to the pilot cap cylinders. A momentary pressure signal applied
activates the valve. When this signal is removed, the alternately to each of the pilot caps shifts the valve.
E
valve shifts. For alternate flow path usages, see Optional For alternate flow path usages, see Optional
Functions page. Functions page.
Mounting
Valve may be mounted in any position.
IN U
Axis of main valve spool to be in horizontal plane.
O
is connected to “Cylinder” Port B. “Cylinder” Port A is Pressure at Port P is connected to “Cylinder” Port A.
connected to “Exhaust” Port EA. “Cylinder” Port B is connected to “Exhaust” Port EB.
I S C
D
A B A B
Pilot A Pilot B
EA P EB EA P EB
8.62
218.9mm
3.83 Single Remote
97.3mm Parts List
1/4 Pipe 1.41 1.41
35.8mm 35.8mm Item Part No. Description
A X B
No.
2 K18R311137 Retaining Ring
1.38
35.1mm 3 K553 011 Washer
2.75
69.8mm * 4 — O-Ring
5 K453 008 Spacer
EA P EB
6 K463 001 End Spacer
1.77 1.77 7 K232 017 Spool Assy.
45.0mm 45.0mm
.35 2.60 * 8 — Seal
8.9mm 66.0mm
5.20
* 9 — Seal
132.1mm
*12 — Gasket
13 H323 027 Remote Cap
15
13 14 H175 12 Lockwasher
14
12 15 H100 60 Cap Screw
3.22 16 K983 003 Shock Pad
81.8mm
* Standard Service Kit: K352 361
1.06 .20
26.9mm 5.1mm
1.84
.49 46.7mm
9 8 2 3 7 4 5 6 16 12.4mm 3.69
93.7mm
7.66
194.6mm Double Remote
3.83
97.3mm
3.83
97.3mm
1.92
48.8mm 1/4 Pipe
1.41 1.41
35.8mm 35.8mm
A X B
.22 1.38
5.6mm 35.1mm
2.75
.22 69.8mm
5.6mm
EA P EB
1.77 1.77
45.0mm 45.0mm
.35 2.60
8.9mm 66.0mm
5.20
132.1mm
Parts List
Item
Part No. Description
9 10
No.
8 11 2 K463 001 End Spacer
3.22 * 3 — O-Ring
81.8mm
4 K453 008 Spacer
1.06 .20
26.9mm 5.1mm 5 K343 046 Spool
1.84 * 6 — Seal
6 2 3 4 5 13 .49 46.7mm
12.4mm 3.69 * 8 — Gasket
93.7mm
9 K323 027 Remote Cap
10 H100 60 Cap Screw
11 H175 12 Lockwasher
13 K983 003 Shock Pad
* Standard Service Kit: K352 358
Application Application
These valves may be used to activate double acting These valves may be used to activate double acting
cylinders. A maintained pressure signal to the pilot cap cylinders. Normally open signals applied to the pilot caps
activates the valve. When this signal is removed, the are alternately bled off to actuate the valve. For alternate
valve shifts. For alternate flow path usages, see Optional flow path usages, see Optional Functions page.
Functions page.
Mounting
Mounting
Axis of main valve spool to be in horizontal plane.
Valve may be mounted in any position.
A B A B
Pilot A Pilot B
EA P EB EA P EB
Model Selection
Valve Port Size (NPT)
Single Remote Double Remote P, A & B EA & EB
L704 71 102 L684 71 102 3/4" 1"
L704 81 102 L684 81 102 1" 1-1/4"
L704 91 102 L684 91 102 1-1/4" 1-1/4"
10.46
265.9mm Single Remote
4.75
120.6mm Parts List
1.62 1.62 Item Part No.
1/4 Pipe 41.1mm 41.1mm Description
A X B
No.
2 H090 09 Retaining Ring
3 K553 009 Spacer
Pilot * 4 — O-Ring (Dynamic)
4.25 * 5 — O-Ring (Static)
108.0mm
2.12 6 K453 009 Spacer
53.8mm
7 K463 005 End Spacer
EA P EB 8 K232 014 Spool Assy.
2.19 2.19 * 9 — Seal
55.6mm 55.6mm
*10 — O-Ring
3.44
87.4mm *12 — Gasket
7.44
189.0mm 13 K323 027 Remote Cap
14 H175 12 Lockwasher
15
13 16
15 H100 60 Cap Screw
14
12 16 K983 004 Shock Pad
4.09 * Standard Service Kit: K352 359
103.9mm
1.50 .20
138.1mm 5.1mm
9 10 2 3 4 56 8 7 .69 5.25
17.9mm 133.4mm
9.50
241.3mm Double Remote
4.75
120.6mm
1.62 1.62 1/4 Pipe
41.1mm 41.1mm
A X B
Pilot Pilot
B A
4.25
108.0mm
2.12
53.8mm
EA P EB
2.19 2.19
55.6mm 55.6mm
3.44
87.4mm Parts List
7.44
189.0mm Item Part No. Description
12
No.
2 K463 005 End Spacer
10 11
13 * 3 — O-Ring (Static)
9
4.09 * 4 — O-Ring (Dynamic)
103.9mm
5 K453 009 Spacer
.20 6 K343 061 Spool
1.50
138.1mm 5.1mm
* 7 — Seal
* 9 — Gasket
7 2 3 4 5 6 .69 5.25 10 K323 027 Remote Cap
17.9mm 133.4mm
11 H175 12 Lockwasher
12 H100 60 Cap Screw
13 K983 004 Shock Pad
* Standard Service Kit: K352 360
4-Way, 4-Port, 3-Position & 4-Way, 5-Port, 3-Position - 1/4" Thru 3/4" NPT Ports
Application
Operation: Pressure Service
These valves may be used to actuate double acting
cylinders, when “inching” or incremental rod movement is Neutral “Class 21”
desired. A “momentary” (exceeding .03 seconds) or Both solenoids de-energized (Normal Condition) –
maintained electrical signal applied to one of the All ports blocked.
solenoids shifts the valve, the valve returns to the
“neutral” condition when the electrical signal is removed. Neutral “Class 22” (L625 Only)
Valve may be applied for alternate service. For alternate Both solenoids de-energized (Normal Condition) –
flow path usages, see Optional Functions page. “Cylinder” Port A is open to “Exhaust” Port E (EA),
“Cylinder” Port B is open to “Exhaust” Port E (EB),
“Pressure” Port P is blocked.
E P
EA P EB
Model Selection (Neutral “Class 21” Shown) Note: Shaded units are no longer available.
11.11
282.2mm 1/2" Basic
5.56
141.2mm
1.41 1.41
35.8mm 35.8mm
A X B
l. A
So
9.64
244.8mm
Parts List
4.82 3/8" BASIC Item Part No.
122.4mm Description
.90 .90 No.
22.9mm 22.9mm
1.82 * 2 — O-Ring (Dynamic)
46.2mm
Typ. A X B
l. A
3 K453 028 Spacer
So
4 K463 012 End Spacer
2.56
65.0mm 5 K343 124 Spool
33 Typ.
1.28 (All Ports Blocked)
l. B 32.5mm
So
1.50 5 K343 126 Spool (Cyl. Ports
38.1mm EA P EB
Typ. Open to Inlet)
.27 DIA.
6.9mm 5 K343 125 Spool (Cyl. Ports
1.33 1.33 2 Holes
33.8mm 33.8mm Open to Exhaust)
1.66 2.34
42.2mm 59.4mm * 6 — Seal
Typ.
4.69 * 8 — Seal
119.1mm
1/2 Pipe 9 K313 049 Piston
Conduit
Connection *10 — Seal
16 17 *14 — Gasket
16 H175 12 Lockwasher
24
5.35
17 H100 60 Cap Screw
135.9mm 24 K152 003 Override Assy.
2
3.91 *27 — O-Ring (Static)
99.3mm 14
.94 29 K983 002 Shock Pad
23.9mm
* Standard Service Kit: K352 126
.53 * Special Service Kit: K352 127
13.5mm
1.62 (Continuous Duty)
.38
29 10 9 8 5 27 3 4 6
9.7mm 3.25 41.1mm
82.6mm
13.63
346.2mm
6.81
1" BASIC
173.0mm
1.62 1.62
41.1mm 41.1mm
Parts List
A X B
Item
Part No. Description
So
l. A No.
4.25
108.0mm 2 K463 005 End Spacer
* 3 — O-Ring (Static)
l. B
So 2.12
53.8mm
* 4 — O-Ring (Dynamic)
1.50 5 K453 009 Spacer
38.1mm EA P EB
Typ. .41 Dia 6 K343 060 Spool
2.19 2.19 10.4mm.
55.6mm 55.6mm 2 Holes (All Ports Blocked)
3.44 6 K343 070 Spool (Cyl. Ports
87.4mm 1/2 Pipe
7.44 Conduit Open to Exhaust)
189.0mm Connection
25 18 17 6 K343 069 Spool (Cyl. Ports
Open to Inlet)
* 7 — Seal
* 9 — Seal
6.44 10 K313 023 Piston
163.6mm
15 *11 — Seal
1.50 *15 — Gasket
38.1mm
17 H175 12 Lockwasher
18 H100 60 Cap Screw
25 K152 003 Override Assy.
.69 5.25
17.5mm 133.4mm 29 K983 004 Shock Pad
29 7 2 4 3 5 6 10 9 11
See Wiring Instructions, page 85, * Standard Service Kit: K352 130
for units with flying leads. * Special Service Kit: K352 131
(Continuous Duty)
Application
These valves may be used to actuate double acting
D
cylinders, when “inching” or incremental rod movement 1/4" Basic 1/2" Basic
is desired. A normally open pilot signal to both pilot caps Pilot B A B Pilot A Pilot B A B Pilot A
E
maintains the valve in its neutral (centered) condition.
Valve may be applied for alternate service. For alternate
flow path usages, see Optional Functions page.
U
P E EA P EB
IN
Pilot B A B Pilot A Pilot B A B Pilot A
Neutral “Class 21”
Normally open pilot signals to both pilot caps –
T
All ports blocked. E P EA P EB
Neutral “Class 22”
N
Normally open pilot signals to both pilot caps – “Cylinder” Pilot B A B Pilot A Pilot B A B Pilot A
Port A is connected to “Exhaust” Port E (EA) and
“Cylinder” Port B is connected to “Exhaust” Port E (EB).
O
Pressure at Port P is blocked. E P EA P EB
Neutral “Class 23”
I
Activated Operation C
Normally open pilot signals to both pilot caps – “Cylinder”
Port A & B are connected to Port P. “Exhaust” Port(s) E
S
When Pilot “A” is exhausted – Pressure at Port P is
D
connected to “Cylinder” Port A. “Exhaust” Port E (EB) is
connected to “Cylinder” Port B.
When Pilot “B” is exhausted – Pressure at Port P is
connected to “Cylinder” Port B, “Exhaust” Port E (EA) is
connected to “Cylinder” Port A.
11.11
282.2mm
5.56
1/2" Basic
141.2mm
3.83
97.3mm
1.41 1.41
35.8mm 35.8mm
1/4 Pipe
A X B
.22
.22 PILOT 5.6mm
5.6mm B
2.75
PILOT 69.8mm
A 1.38
35.1mm
EA P EB Parts List
.35 Item
8.9mm Part No. Description
1.77 .1.77 No.
45.0mm 8.9mm
5.20 2 K463 001 End Spacer
132.1mm
* 3 — O-Ring
10 4 K453 008 Spacer
9
11
8 5 K343 045 Spool
3.22 (All Ports Blocked)
81.8mm
5 K343 057 Spool (Cyl. Ports
Open to Inlet)
1.06 .20
26.9mm 5.1mm 5 K343 068 Spool (Cyl. Ports
1.84
Open to Exhaust)
.49 46.7mm
6 6 2 3 4 5 12 13 7 14 12.4mm 3.69
* 6 — Seal
93.7mm 7 K313 017 Piston
* 8 — Gasket
9 K323 027 Remote Cap
10 H100 60 Cap Screw
11 H175 12 Lockwasher
*12 — Seal
*13 — Seal
14 K983 003 Shock Pad
* Standard Service Kit: K352 358
EA P EB
13.62
345.9mm 1" Basic
6.81
173.0mm
1.62 1.62
41.1mm 41.1mm
A X B
4.25
PILOT
B
PILOT
A
108.0mm
2.13
54.0mm
Parts List
Item
Part No. Description
EA P EB
No.
2.19 2.19 2 K463 005 End Spacer
55.6mm 55.6mm
3.44
87.4mm * 3 — O-Ring (Static)
7.44
189.0mm * 4 — O-Ring (Dynamic)
1/4 Pipe 10 5 K453 009 Spacer
12 6 K343 060 Spool
10 11 (All Ports Blocked)
4.09
9 103.9mm 9
6 K343 070 Spool (Cyl. Ports
Open to Exhaust)
1.50
38.1mm 6 K343 069 Spool (Cyl. Ports
Open to Inlet)
.20
5.1mm * 7 — Seal
5.25 8 K313 023 Piston
.69 133.4mm
17.5mm * 9 — Gasket
15 7 2 3 4 5 6 8 13 14
10 K323 027 Remote Cap
11 H175 12 Lockwasher
12 H100 60 Cap Screw
*13 — Seal
*14 — Seal
15 K983 004 Shock Pad
* Standard Service Kit: K352 360
Time Delay Modules Provide By adding a small external reservoir, delay interval can be
extended up to several minutes.
• Delay of valve action upon application of control signal,
removal of control signal or both application and For accuracy and good repeatability, use filtered air to the
removal of control signal. pilot and be sure all gaskets are tight.
• Delay Intervals from 0-6, 5-12, or 10-30 seconds...
Setting Selector for Desired Function
up to several minutes with the addition of a small
external reservoir. For Valves which are Solenoid Pilot Operated, or Valves
• Repeatability within 10%, using clean filtered air. being controlled by normally open remote pilot, match the
pointer marked “Elect” with the desired function indicator
• Change of function without disassembly... with line
line.
pressure on the valve.
For Valves which are being controlled by normally closed
Function pilot, match the pointer marked “Air” with the desired
function indicator line.
Time Delay Modules provide precise, consistent delay of
valve shift. They eliminate the need for electrical timers and How To Order
relays and simplify circuitry.
To order Time Delay Modules, select model number for
Delay interval is controlled by an externally adjustable delay interval required. Modules are furnished with gaskets,
metering screw. Change of function is accomplished by screws, and installation instructions.
loosening two lock screws turning the slotted selector plate
to the desired function and re-tightening the lock screws.
Plug-In Kit Number Delay Interval Non Plug-In Kit Number Delay Interval
K705 2001 0 - 6 Second Delay K705 1001 0 - 6 Second Delay
K705 2002 5 - 12 Second Delay K705 1002 5 - 12 Second Delay
K705 2003 10 - 30 Second Delay K705 1003 10 - 30 Second Delay
.66 .66
17mm 17mm
1.31 1.31
33mm To Main 33mm
To Pilot Valve
Notes: Shaded units are not standard stock items. Effective June 1, 1990 the Flush Locking Override replaced the
Extended Knob Locking Override as the Schrader Bellows standard.
The part number remains K152 003. To override valve, use a flat
L head screwdriver to press in and rotate plunger 90° until plunger
** locks in place. For proper valve operation, override should be in the
Voltage Code out position.
To use this chart you must know the Basic Valve Series, Quantity, and Type of Operators, or the first three characters of
the Valve Model Number.
Solenoid Operated *
Basic Remote Pilot
Valve Standard Service Special Service ** Operated
(Intermittent Duty) (Continuous Duty)
Series Double Double Double
Size Single Single Single
(Prefix) 2 & 3-Position 2 & 3-Position 2 & 3-Position
L41 – K352 151 – K352 351 – K352 357
L42 – K352 151 – K352 351 – K352 357
L44 K352 150 – K352 350 – K352 363 –
1/4"
L46 – K352 151 – K352 351 – K352 357
L47 – K352 151 – K352 351 – K352 357
L48 K352 150 – K352 350 – K352 363 –
L65 – K352 126 – K352 127 – K352 355
L66 – K352 126 – K352 127 – K352 355
L67 K352 124 – K352 125 – K352 362 –
3/8"
L68 – K352 126 – K352 127 – K352 355
*
L69 – K352 126 – K352 127 – K352 355
L70 K352 124 – K352 125 – K352 362 –
L51 – K352 153 – K352 353 – K352 358
L52 – K352 153 – K352 353 – K352 358
L54 K352 152 – K352 352 – K352 361 –
1/2"
L61 – K352 153 – K352 353 – K352 358
L62 – K352 153 – K352 353 – K352 358
L64 K352 152 – K352 352 – K352 361 –
L65 – K352 130 – K352 131 – K352 360
L66 – K352 130 – K352 131 – K352 360
1" L67 K352 128 – K352 129 – K352 359 –
† L68 – K352 130 – K352 131 – K352 360
L69 – K352 130 – K352 131 – K352 360
L70 K352 128 – K352 129 – K352 359 –
Notes:
* Kits for solenoid operated valves include solenoid service kits.
** Special service (continuous duty) solenoids may be identified as having gold colored solenoid tops.
† Valvair II valves are easily identified by gold colored valve end caps.
Replacement Pilots
Description Standard Service Special Service
Override Type Locking Non-Locking Locking Non-Locking
With Override (120VAC) K175 9035 53 K175 8035 53 K185 9025 53 K185 8025 53
With Override (Other than 120VAC) K175 3035 K175 2035 K185 3025 K185 2025
** ** ** **
1.63 ** See voltages on page 75.
41.4mm 1.28
32.5mm
11
16
16 2 19 20
3.12 7
79.2mm 28 2
23 21
18 7
24 8
4
8
.81 .69
20.6mm .53 .47
13 13.5mm 11.9mm 17.9mm Special Service
Pilot Only
1.81DIA
2.62 46.0mm
25 66.5mm 5
Standard Pilot Only
Parts List
Item No. Part Number Description Item No. Part Number Description
K423 005 Top Seat (STD. Service) * 16 H142 01 Seal
2
K423 010 Top Seat (SPL. Service) 18 K152 003 Override Assembly
*4 H142 13 Seal 19 K213005 Insert
*5 K183 001 Gasket * 20 H134 13 O-Ring
*7 H249 69 O-Ring * 21 H134 73 O-Ring
K343 002 Plunger (STD. Service)
*8 * 23 H134 58 O-Ring
K343 001 Plunger (SPL. Service)
* 24 H134 62 O-Ring
H191 05 Light (120 AC)
11 * 25 K333 002 Plug
H191 12 Light (24VDC)
28 K183 108 Gasket
K593 125 Coil 120V 60Hz / 110V 50 Hz,
for Indicator Light** * Parts included in Service Kit. (For other voltages see page 75.)
K593 071 Coil 120V 60Hz / 110V 50Hz Special Service Kit K352 366
Standard Service Kit K352 166
K593 081 Coil 240V 60 Hz / 220V 50 Hz
K593 048 Coil 6VDC / 12V 60Hz ** Light not included with coil.
13 Note: Shaded units are no longer available.
K593 055 Coil 12VDC
K593 274 Coil 24VDC, for Indicator Light**
K593 060 Coil 24VDC
Replacement Pilots
Description Standard Service Special Service
Override Type Locking Non-Locking Locking Non-Locking
Basic with Override K065 3035 K065 2035 K085 3025 K085 2025
** ** ** **
JIC with Junction Box & Override K065 6035 K065 5035 K085 6025 K085 5025
** ** ** **
JIC Pilot with Junction Box &
K065 9035 ** K065 8035 ** K085 9025 ** K085 8025 **
Override & Indicator Lights (120VAC Only)
** See voltages on page 77.
2.62
66.5mm
2.81 6
1.28 71.4mm 21
32.5mm 1.81 1.50
46.0mm 38.1mm 11
1/2 N.P.T. 8
10 Conduit
Connection 4
13 12 20
3.05
77.5mm 24
6
1.62 5
41.3mm
.81 .69 11
20.6mm .53
13.5mm 17.5mm
Special Service 18
1.47 1.81 DIA. Pilot Only 8
37.3mm 16 14 46.0mm
Parts List
Item No. Part Number Description Item No. Part Number Description
K593 025 Coil 120V 60Hz / 110V 50Hz 12 K272 004 Plunger Guide
K593 035 Coil 240V 60Hz / 220V 50Hz 13 K152 003 Override Assembly
K593 003 Coil 6VDC / 12V 60Hz * 14 K183 047 Cover Gasket
4
K593 010 Coil 12VDC * 16 K183 001 Gasket
K593 014 Coil 24VDC * 18 H134 73 O-Ring
K593 041 Coil 120VDC * 20 H134 13 O-Ring
5 H142 13 Seal * 21 H147 01 Shock Pad
K423 006 Top Seat 22 H191 02 120 AC Only – Indicator Light
6
K423 010 Top Seat (SPL. Service Pilot) 24 K183 108 Gasket
K343 002 Plunger (STD. Service) Coil leads are 19" long (For other voltages see page 75).
8
K343 001 Plunger (SPL. Service) * Parts included in Service Kit.
* 10 H142 01 Seal Special Service Kit K352 366
Standard Service Kit K352 166
* 11 H249 69 O-Ring
NOTE: Shaded units are no longer available.
Replacement Pilots
Description Standard Service Special Service
Hazardous Duty Pilot - UL & CSA K025 1035 ▲ K045 1025 ▲
** **
NEMA 4 Pilot K235 1035 ▲ K255 1025 ▲
** **
Override Type Locking Non-Locking Locking Non-Locking
Hazardous Duty with Override K025 3035 ▲ K025 2035 ▲ K045 3025 ▲ K045 2025 ▲
** ** ** **
NEMA 4 with Override K235 3035 ▲ K235 2035 ▲ K255 3025 ▲ K255 2025
** ** ** **
▲ 49 / 53 only ** See voltages on page 77.
2.87
72.9mm
17
1/2 NPT 10
Conduit 11
6 Connection
Parts List
Item No. Part Number Description Item No. Part Number Description
K343 002 Plunger (STD. Service) 12 K152 003 Override Assembly
*4
K343 001 Plunger (SPL. Service) * 13 H134 73 O-Ring
*5 K142 13 Seal * 17 H137 16 Gasket (NEMA 4 Rated Pilot Only)
H134 11 O-Ring * 18 K183 001 Gasket
*6
H134 61 O-Ring (STD. Service) Coil leads are 19" long (For other voltages see page 75).
*7 H249 69 O-Ring (SPL. Service) * Parts included in Service Kit.
K423 001 Top Seat Special Service Kit K352 366
10
K423 002 Top Seat (SPL. Service) Standard Service Kit K352 166
K593 025 Coil 120V 60Hz / 110V 50Hz NOTE: Shaded units are no longer available.
K593 035 Coil 240V 60Hz / 220V 50Hz
K593 003 Coil 6VDC / 12V 60Hz
11
K593 010 Coil 12VDC
K593 014 Coil 24VDC
K593 041 Coil 120VDC
Speed King, Valves are exceptionally versatile and may be used to perform a wide variety of functions, some of which
are illustrated here for your convenience.
4-Ported Valves 5-Ported Valves
A B A B
Standard 4-Way
Directional Control
E P
EA P EB
A B A B
PLUG A B PLUG A B
A B PLUG A B PLUG
A B PLUG A B PLUG
Pressure Selector
P1 Must Be 35-140 PSI
P2 May Be 0-250 PSI or Vacuum E P PLUG EA EB PLUG
(P2) (P1) (P2) P
(P1)
PLUG A B PLUG A B
A B PLUG A B PLUG
A B
The capacity curves shown in the chart are for theoretical valve having a Cv - 1.0 for air at standard
conditions –temperature 68°F, 36% relative humidity and 14.7 PSI absolute pressure.
To estimate the SCFM capacity of a valve, if the supply or initial pressure is known, proceed as follows:
Assuming initial pressure to 100 PSIG, select the 100 PSI initial pressure curve and follow it
upward and to the left edge of the chart. Read the flow in SCFM (in this example flow is approximately
56 SCFM). Multiply the SCFM flow obtained in the chart by the Cv for valve and flow path desired
shown in the accompanying table.
To estimate valve size for a known required flow and initial pressure, divide the required SCFM flow by
the SCFM obtained from the flow chart. Select the required valve size from the valves listed in the table
which have a Cv that slightly exceeds the quotient.
For example: Assuming 200 SCFM required flow, 100 PSIG initial pressure, divide 200 SCFM by
56 SCFM (max. flow from chart). The quotient is 3.57 (200/56 = 3.57). Valves with a Cv of 3.57 or
greater selected from the table will provide the required flow.
To estimate flow capacity at a specific “final pressure,” locate the desired final pressure on the bottom
scale of the chart. Follow a vertical line upward until it intersects the initial pressure curve. Then follow a
horizontal line from that point to the left edge of the chart. Read SCFM flow. Multiply SCFM obtained in
chart by Cv of selected valve for flow.
Cv Method
Data at Std. Conditions G = Specific Gravity of fluid related to air = 1 @
68°F Temperature 14.7 psia, 68°F, 36% Relative Humidity
14.7 PSI Abs. Pressure P2 = Downstream Pressure (psia)
36% Relative Humidity Pc = Component pressure drop
Q = Flow Rate (scfm) at 14.7 psia, 68°F,
( Pc) x (P 2) 36% Relative Humidity
Q = 22.48 Cv (T1) x (G)
T1 - Upstream Temperature °R (°R = °F + 460)
Flow Rating determined in accordance with
Cv = Flow Coefficient
NFPA recommended Standard NFPA/T3.21.3-1972.
90
80
70
0
15
0
60 14
0
13
FLOW IN SCFM
0
12
50 0
11
0 0 IG
1 S
40 90 N P
I
80 RE
30 70 SSU
E
60 PR
50 IAL
T
20
40 INI
30
10 20
10
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
FINAL PRESSURE IN PSIG
Materials of Construction
Life Expectancy
Valve Bodies: Aluminum alloy
Valves designed for non-lubricated service as well as
those designed for lubricated service will provide
Valve Spool: * Aluminum alloy with special coating on
millions of maintenance free cycles. Under laboratory
3/8" & 1" basic valves
conditions service life exceeds 25,000,000 cycles!
Hard chrome plated AISI type 416
stainless steel on 1/4" & 1/2"
basic valves.
Factory Pre-Lubrication
Resilient Seals: In Valve Body - Valves are lubricated at assembly with Sunaplex 781
Dynamic: Polyurethane base on or equivalent. Valves specified for vacuum service are
3/8" & 1" basic valves* lubricated with Dow Corning Valve Seal A.
Valve Selection
Safety factors are designed into each valve. However,
it is important that the application requirements do not
exceed the limits stated for pressure and temperature.
“Nominal Cv” ratings are given on each ordering page.
These represent an average of performance for all
flow-paths of a given valve size. Valves should be
sized to an application using actual Cv (Flow
Coefficient) values. See Flow Capacities Section for
this data.
Caution
If it is possible that the ambient temperature may fall
below freezing, the medium must be moisture free to
Special Service (Continuous Duty) prevent internal damage and unpredictable behavior.
Solenoid Operator
Maximum
Minimum
Intermittent Duty Continuous Duty
0°F 125°F 125°F
As the above chart indicates, Standard Duty Solenoids
may be used on continuous duty but ambient temperature
is de-rated.
In some cases, Special Service Solenoids may be rated
for higher ambient temperatures (consult supplier).
General Purpose
Conduit / Flying Lead CSA 1 & 12 Indoor Only
Dust Tight
General Purpose
* Conduit CSA 4 Indoor / Outdoor
(As Specified)
Watertight
* See ordering information on specific valve type. (Direct Pipe Ported Valves Only.)
L4652Y10261 Refer to Service Kits L4752291153 Refer to Service Kits L4852310262 Refer to Service Kits
L4652Z10253 L4653Z10253 L4752321143 Refer to Service Kits L4852310445 Refer to Service Kits
L4652210249 L4653310249 L4752321153 L4753321153 L4852310449 L4853310449
L4652210253 L4653310253 L4752321157 L4753321157 L4852310453 L4853310453
L4652210257 L4653310257 L4752322149 Refer to Service Kits L4852310457 Refer to Service Kits
L4652260253 L4653360253 L4752322153 Refer to Service Kits L4852310459 Refer to Service Kits
L4652260453 L4653360453 L4752323153 Refer to Service Kits L4852360249 L4853360249
L4652280253 L4653380253 L4752371145 Refer to Service Kits L4852360253 L4853360253
L4652310240 Refer to Service Kits L4752371153 Refer to Service Kits L4852360257 L4853360257
L4652310242 Refer to Service Kits L4752372153 Refer to Service Kits L4852360449 L4853360449
L4652310245 Refer to Service Kits L4752391153 Refer to Service Kits L4852360453 L4853360453
L4652310249 L4653310249 L4752621145 Refer to Service Kits L4852360457 Refer to Service Kits
L4652310453 L4653310453 L4752623151 Refer to Service Kits L4852410245 Refer to Service Kits
L4652360249 L4653360249 L4752623153 Refer to Service Kits L4852410253 L4853610253
L4652360253 L4653360253 L4752921153 L4753921153 L4852510245 Refer to Service Kits
L4652360257 Refer to Service Kits L4752922153 Refer to Service Kits L4852510249 L4853610249
L4652380357 Refer to Service Kits L4852W60253 L4853Z60253 L4852610243 Refer to Service Kits
L4652380453 L4653380453 L4852W60453 L4853Z60453 L4852610245 Refer to Service Kits
L4652510249 L4653610249 L4852W80253 L4853Z80253 L4852610249 L4853610249
L4652510253 L4653610253 L4852W80453 L4853Z80453 L4852610251 Refer to Service Kits
L4652610261 Refer to Service Kits L4852160253 L4853360253 L4852610460 Refer to Service Kits
L4652610353 L4653610353 L4852210249L L4853310249 L4852610461 Refer to Service Kits
L4652610451 Refer to Service Kits L4852210253 L4853310253 L4852810253 L4853810253
L4652610457 Refer to Service Kits L4852260253 L4853360253 L4852810453 L4853810453
L4452W10249 L4452Z10249
L4452W10253 L4452Z10253
L4452W10449 L4452Z10449
L4452110249 L4452310249
L4452110253 L4452310253
L4452110257 L4452310257
L4452110449 L4452310449
L4452110453 L4452310453
L6553310242 Refer to Service Kits L685D610257L L6854640257 L6854610242 Refer to Service Kits
L6553310249S L6553310249 L685D610259 Refer to Service Kits L6854610259 Refer to Service Kits
L6553310251 Refer to Service Kits L685M910253 L6854910253 L6854610261 Refer to Service Kits
L6553310259 Refer to Service Kits L6853110253 L6853310253 L6953121153 L6953321153
L6653221149 L6653321149 L6853310240 Refer to Service Kits L6953322161 Refer to Service Kits
L6653221153 L6653321153 L6853310253L L6853310253 L6953371553L L6953371553
L6653221157 L6653321157 L6853310261 Refer to Service Kits L6953422153 L6953622153
L6653222153 L6653322153 L6853360251 Refer to Service Kits L6953521153 L6953621153
L6653223149 L6653323149 L6853380261 Refer to Service Kits L6953621159 Refer to Service Kits
L6653223153 L6653323153 L6853410349 L6853610349 L6953621161 Refer to Service Kits
L6653223553 L6653323553 L6853610251 Refer to Service Kits L6953622140 Refer to Service Kits
L6653321159 Refer to Service Kits L6853610261 Refer to Service Kits L6953721153 L6953821153
L6155310249 L6156310249 L6255822153 Refer to Service Kits L6455610449 Refer to Service Kits
L6155310253 L6156310253 L6255921149 L6256921149 L6455610453 Refer to Service Kits
L6155310257 L6156310257 L6255921153 L6256921153 L6455610457 Refer to Service Kits
L6155310261 Refer to Service Kits L6255921553 Refer to Service Kits L6455610461 Refer to Service Kits
L6155310349 Refer to Service Kits L6255922149 Refer to Service Kits L6455710253 L6456810253
L6155310462 Refer to Service Kits L6255922153 Refer to Service Kits L6455810253 L6456810253
L6155360253 Refer to Service Kits L6255922553 Refer to Service Kits L6455810453 Refer to Service Kits
L6155360257 Refer to Service Kits L6255923153 Refer to Service Kits L6455910253 L6456910253
L6155380253 Refer to Service Kits L64451102 Refer to Service Kits L6455910253L L6456910253
L6155380449 Refer to Service Kits L64461102 Refer to Service Kits L6455910449 L6456910249
L6155380453 Refer to Service Kits L645D360253 Refer to Service Kits L6455910453 Refer to Service Kits
L6155410253 L6156610253 L645N310249 L6456310249 L645P310457 Refer to Service Kits
L6255271553 Refer to Service Kits L6455310245 Refer to Service Kits L5155910353 Refer to Service Kits
L6255272153 Refer to Service Kits L6455310249 L6456310249 L5155910453 Refer to Service Kits
L6255273153 Refer to Service Kits L6455310253 L6456310253 L52451211 Refer to Service Kits
L6255321143 Refer to Service Kits L6455310253L L6456310253 L52451221 Refer to Service Kits
L6255321145 Refer to Service Kits L6455310257 L6456310257 L5255Z21553 Refer to Service Kits
L6255321149 L6256321149 L6455310261 Refer to Service Kits L5255Z22153 Refer to Service Kits
L6255321153 L6256321153 L6455310353 Refer to Service Kits L5255Z22153 Refer to Service Kits
L6255321345 Refer to Service Kits L6455310445 Refer to Service Kits L5255Z22553 Refer to Service Kits
L6255322142 Refer to Service Kits L6455310453 Refer to Service Kits L5255Z23553 Refer to Service Kits
L6255322153 Refer to Service Kits L6455360249 Refer to Service Kits L5255122153 Refer to Service Kits
L6255322553 Refer to Service Kits L6455360253 Refer to Service Kits L5255221149 L5255321149
L6255323153 Refer to Service Kits L6455360453 Refer to Service Kits L5255221153 L5255321153
L6255371153 Refer to Service Kits L6455380253 Refer to Service Kits L5255221557 Refer to Service Kits
L6255371553 Refer to Service Kits L6455380453 Refer to Service Kits L5255222149 Refer to Service Kits
L6255391153 Refer to Service Kits L6455410257 L6456610257 L5255222153 Refer to Service Kits
L6255521142 Refer to Service Kits L6455410461 Refer to Service Kits L5255223153 Refer to Service Kits
L5255321553 Refer to Service Kits L6156W10242 Refer to Service Kits L645P910253 L6456910253
L5255321557 Refer to Service Kits L6156W10253 L615WZ10253 L6456W10251 Refer to Service Kits
L5255322143 Refer to Service Kits L6156310240 Refer to Service Kits L6456W10253 L6456Z10253
L5255322149 Refer to Service Kits L6156310242 Refer to Service Kits L6456W10453 Refer to Service Kits
L5255322153 Refer to Service Kits L6156310249L L615WZ10249 L6456W60253 Refer to Service Kits
L5255322157 Refer to Service Kits L6156310261 Refer to Service Kits L6456W60257 Refer to Service Kits
L5255322549 Refer to Service Kits L6156310453 Refer to Service Kits L6456W80249 Refer to Service Kits
L5255323143 Refer to Service Kits L6156360253 Refer to Service Kits L6456W80253 Refer to Service Kits
L5255323149 Refer to Service Kits L6156380253 Refer to Service Kits L6456W80257 Refer to Service Kits
L5255323153 Refer to Service Kits L6156410253 L6156610253 L6456W80453 Refer to Service Kits
L5255323157 Refer to Service Kits L6156510249 L6156610249 L6456Y10249 L6456Z10249
L5255323549 Refer to Service Kits L6156610245 Refer to Service Kits L6456Y10257 L6456Z10257
L5255822553 Refer to Service Kits L6156910353 Refer to Service Kits L6456280457 Refer to Service Kits
L5255823149 Refer to Service Kits L6156910449L Refer to Service Kits L6456310261 Refer to Service Kits
L5255823153 Refer to Service Kits L6256W21153 L6256Z21153 L6456310445 Refer to Service Kits
L5255823553 Refer to Service Kits L6256121145L Refer to Service Kits L6456310453 Refer to Service Kits
L5255823553 Refer to Service Kits L6256121153 L6256321153 L6456310457 Refer to Service Kits
L5255921353 Refer to Service Kits L6256171153 Refer to Service Kits L6456360249 Refer to Service Kits
L5255921553 Refer to Service Kits L6256221153 L6256321153 L6456360253 Refer to Service Kits
L5255922149 Refer to Service Kits L6256321553 Refer to Service Kits L6456360257 Refer to Service Kits
L5255922153 Refer to Service Kits L6256321557 Refer to Service Kits L6456360453 Refer to Service Kits
L5255922553 Refer to Service Kits L6256322149 Refer to Service Kits L6456380245 Refer to Service Kits
L5255923153 Refer to Service Kits L6256322153 Refer to Service Kits L6456380253 Refer to Service Kits
L5255923553 Refer to Service Kits L6256371153 Refer to Service Kits L6456380253L Refer to Service Kits
L54451102 Refer to Service Kits L6256371553 Refer to Service Kits L6456380445 Refer to Service Kits
L5455Z10453 Refer to Service Kits L6256372153 Refer to Service Kits L6456380453 Refer to Service Kits
L5455110249 L5455310249 L6256391153 Refer to Service Kits L6456510253 L6456610253
L5455110253 L5455310253 L6256392149 Refer to Service Kits L6456610245 Refer to Service Kits
L5455110453 Refer to Service Kits L6256392153 Refer to Service Kits L6456610251 Refer to Service Kits
L5455210245 Refer to Service Kits L6256393153 Refer to Service Kits L6456610259 Refer to Service Kits
L5455210249 L5455310249 L6256621140 Refer to Service Kits L6456610261 Refer to Service Kits
L5455210253 L5455310253 L6256621145 Refer to Service Kits L6456610449 Refer to Service Kits
L5455210257 L5455310257 L6256621161 Refer to Service Kits L6456610449 Refer to Service Kits
L5455310242 Refer to Service Kits L6256621561 Refer to Service Kits L6456610453 Refer to Service Kits
L5455310245 Refer to Service Kits L6256622153 Refer to Service Kits L6456610453 Refer to Service Kits
L5455310251 Refer to Service Kits L6256622157 Refer to Service Kits L6456610461 Refer to Service Kits
L5455310259 Refer to Service Kits L6256622353 Refer to Service Kits L6456710253 L6456810253
L5455310353 Refer to Service Kits L6256921353 Refer to Service Kits L6456810453 Refer to Service Kits
L5455310451 Refer to Service Kits L6256921549 Refer to Service Kits L6456810453 Refer to Service Kits
L5455310453 Refer to Service Kits L6256921553 Refer to Service Kits L6456910353 Refer to Service Kits
L5455310457 Refer to Service Kits L6256922153 Refer to Service Kits L6456910353 Refer to Service Kits
L5455310459 Refer to Service Kits L6256922549 Refer to Service Kits L6456910453 Refer to Service Kits
L5455710253 L5455810253 L6256922553 Refer to Service Kits L6456910453 Refer to Service Kits
L5455810449 Refer to Service Kits L6256923153 Refer to Service Kits
L6558210259 Refer to Service Kits L6857610261 Refer to Service Kits L6957623153 Refer to Service Kits
L6558210459 Refer to Service Kits L6857610353 L6858610353 L6957921149 L6958921149
L6558310242 Refer to Service Kits L6857610457 L6858610457 L6957921153 L6958921153
L6558310243 Refer to Service Kits L6857810253 L6858810253 L6957921553 L6958921553
L6658722153 L6658822153 L6858410461 Refer to Service Kits L6959523153 Refer to Service Kits
L6658923153 Refer to Service Kits L6858510249 L6858610249 L6959623157 Refer to Service Kits
L6758W10249 L6758Z10249 L6859210253 L6858310253 L6959923153 Refer to Service Kits
L6758110249 L6758310249 L6859310253 L6858310253 L70471102 L70481102
L7058Y10445 L7058Z10445
L7058210253 L7058310253
L7058260453 L7058360453
L7058280253 L7058380253
L7058280453 L7058380453
L7058380253L L7058380253
L7058380453L L7058380453
L7058610243 Refer to Service Kits
L7059210257 L7058310257
L7059280453 L7058380453
L7059310249 L7058310249
L7059310253 L7058310253
L7059310257 L7058310257
L7059360249 L7058360249
L7059360253 L7058360253
L7059380253 L7058380253
L7059410253 L7058610253
L7059610249 L7058610249
L7059610253 L7058610253
L7059610257 L7058610257
L7059910253 L7058910253
L7059910453 L7058910453
SK200 1/4"
Specials Description Repair Kit Closest Replacement
L38053001 Single Solenoid, less base, with fluorocarbon seals N/A L38539104 + voltage
L38054001 Single Solenoid, less base, less pilot valve K352088 L3854 X 102 + voltage
L41052001 Plug-In Speed King Valve with lubrication for dry service K352151 L41529102 + voltage
L41052002 Plug-In Speed King Valve with indicator light for 230 / 50Hz K352151 L4152310257
L41052003 Plug-In Speed King Valve with Lockwire and “VH” O-rings K352151 L41529102 + voltage
L41052004 Plug-In Valve one remote cap and one remote time delay and K352151 L41421102 + Time Delay
less electrical plug
L41052005 Less subbase with remote caps and less electrical plug K352357 L41421102
L41052006 Plug-In Valve with Lockwire on end caps and Lockwired to subbase K352151 L41529102 + voltage
L41052011 Double Solenoid with special sealing agent on electrical plug K352151 L4152910253
L41052012 Double Solenoid with stainless steel spool K352151 N/A
L41052013 Double Solenoid with fluorocarbon seals N/A N/A
L42052001 Double Solenoid with speed controllers K352151 L42529231** + 003381101
L42052006 Double Solenoid, with Normally Open and Normally Closed pilots K352151 L42529211 + voltage
L42052007 Double Solenoid, ABP, with stainless steel spool K352151 N/A
L42052008 Double Solenoid, CE, with stainless steel spool K352151 N/A
L42052009 Double Solenoid, PC, with stainless steel spool K352151 N/A
L44052013 Single Solenoid, with polyurethane O-rings and 200 PSI pilot N/A N/A
L44052014 Single Solenoid, with solid state controls K352150 N/A
L44052015 Single Solenoid, with sealing agent on electrical plug K352150 L44529102 + voltage
L44052016 Single Solenoid, with stainless steel spool K352150 N/A
L46042002 Double Remote Pilot, with internal pilot supply K352357 N/A
L46042003 Double Remote Pilot, with cylinder operators K352357 N/A
L46042004 Double Remote Pilot, with time delay K352357 L46421102 + time delay module
L46042005 Double Remote Pilot, with fluorocarbon O-rings N/A N/A
L46043001 Double Remote Pilot, with adapters for air bleed assemblies K352357 N/A
L46052001 Double Solenoid, with special coil K352151 N/A
L46052002 Double Solenoid, with special coil K352151 N/A
L46052003 Double Solenoid, with external pilot supply K352151 L4652410**
SK200 1/4"
Specials Description Repair Kit Closest Replacement
L46052004 Double Solenoid, with special lubricant N/A N/A
L46052005 Double Solenoid, with high temperature - Nema 4 coil, 125VDC K352151 N/A
L46052006 Double Solenoid, with special pilot K352151 N/A
L46052007 Double Solenoid, less pilot valve K352151 L4652 * 102 **
L48042003 Single Remote Pilot, inline valve, with fluorocarbon O-rings N/A N/A
L48043001 Single Remote Pilot, inline valve, with special pilot cap K352363 L48431102
L48052001 Single Solenoid, inline valve, with high temperature seals N/A N/A
L48052002 Single Solenoid, inline valve, with special lubrication N/A N/A
L48052003 Single Solenoid, inline valve, with high temperature seals N/A N/A
L48052004 Single Solenoid, inline valve, with Class “H” coil, 115V / 60Hz, K352150 N/A
continuous duty
L48052005 Single Solenoid, inline valve, with Class “H” coil, 125VDC, K352150 N/A
hazardous location
L48052006 Single Solenoid, inline valve, less coil K352150 L48529102 **
L48052007 Single Solenoid, inline valve, with special pilot, less coil K352150 N/A
L48052008 Single Solenoid, inline valve, with special NC pilot valve K352150 N/A
L48052009 Single Solenoid, inline valve, with polyurethane O-rings K352150 N/A
L48052010 Single Solenoid, inline valve, with special lubrication N/A N/A
L48052011 Single Solenoid, inline valve, with 6 foot leads on coils K352150 L48523102 + voltage
L48052012 Single Solenoid, inline valve, with suppressors K352150 L48529102 + voltage
L48052013 Single Solenoid, inline valve, with special override and 36 inch leads K352150 L48529102 + voltage
L48052014 Single Solenoid, inline valve, with 36 inch leads K352150 L4852310253
L48052015 Single Solenoid, inline valve, less coil K352150 L48523604 + voltage
L48053001 Single Solenoid, inline valve, with Class “H” coil, Nema 4, 115V / 60Hz K352150 N/A
L48053002 Single Solenoid, inline valve, with Class “H” coil, hazardous and K352150 N/A
continuous duty
L48053003 Single Solenoid, inline valve, with special non-locking override K352150 L48536102 + voltage
L48053004 Single Solenoid, inline valve, with Class “H” coil, Nema 4 K352150 N/A
L48053005 Single Solenoid, inline valve, with Class “H” coil, Nema 4 125VDC K352150 N/A
L48053006 Single Solenoid, inline valve, with fluorocarbon seals N/A N/A
L48053007 Single Solenoid, inline valve, with special non-locking override K352150 L4853610253
L48053008 Single Solenoid, inline valve, with special 125VDC coil K352150 N/A
L48053009 Single Solenoid, inline valve, with 55V / 60Hz rating K352150 N/A
SK200 3/8"
Specials Description Repair Kit Closest Replacement
L6504C001 Double Remote Pilot, with subbase, with fluorocarbon N/A N/A
L65053001 Double Solenoid, less base, with drilled pilot exhaust K352126 L65533102 + voltage
L65053002 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553910253
L65053003 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553810253
L65053004 Double Solenoid, less base, with drilled pilot exhaust K352126 L65532102 + voltage
L65053005 Double Solenoid, less base, with drilled pilot exhaust K352126 L6553210261
L65053006 Double Solenoid, less base, with fluorocarbon O-rings N/A N/A
L65053007 Double Solenoid, less base, with blank pilot spacer K352126 N/A
L65053008 Double Solenoid, less base, with one NC and one NO solenoid K352126 N/A
L65053009 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053010 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053011 Double Solenoid, less base, with class “H” coil and 10 foot leads K352126 N/A
L65053012 Double Solenoid, less base, with special spool K352126 N/A
L65053013 Double Solenoid, less base, with drilled pilot exhaust K352126 N/A
L65053014 Double Solenoid, less base, with blocked inlet port K352126 N/A
L65053015 Double Solenoid, less base, with blocked inlet port K352126 N/A
L65053016 Double Solenoid, less base, with blocked exhaust ports K352126 N/A
L65053017 Double Solenoid, less base, with gasket plate K352126 L65539102 + voltage
L65053018 Double Solenoid, less base, with stainless steel stem K352126 N/A
L65053019 Double Solenoid, less base, with special spring return override K352126 L6553910253
L65053020 Double Solenoid, less base, with low-temperature lube and N/A N/A
stainless steel spool
L65053021 Double Solenoid, less base, with blocked inlet port K352126 N/A
L66043001 Double Remote Pilot, with special drilling K352355 N/A
L66043002 Double Remote Pilot, with special drilling K352355 N/A
L66053005 Double Solenoid, less base, with one continuous duty solenoid and K352126 N/A
special pistons
L66053006 Double Solenoid, less base, with blank exhaust spacers K352126 N/A
L66053007 Double Solenoid, less base, with 75VDC coil K352126 N/A
L66053008 Double Solenoid, less base, with 125VDC coil K352126 L6653221161
L66053009 Double Solenoid, with base, with grounding screw in base K352126 L66539211 + voltage
L66053011 Double Solenoid, less base, with one NO and one NC solenoid K352126 N/A
L66053012 Double Solenoid, less base, with 32VDC coil K352126 N/A
L66053014 Double Solenoid, less base, with remote adapters K352126 N/A
L66053015 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053016 Double Solenoid, less base, with one NO and one NC solenoid K352126 N/A
L66053018 Double Solenoid, less base, with special override K352126 L6653923153
L66053019 Double Solenoid, less base, with conduit type operators K352126 N/A
L66053020 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053021 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053022 Double Solenoid, less base, with blank inlet spacer K352126 N/A
L66053024 Double Solenoid, less base, with 37VDC coil K352126 N/A
L67043001 Single Remote Pilot, Valve only, with timing sequence delay K352362 L67431102 + K7051003
L67043002 Single Remote Pilot, Valve only, with timing sequence delay K352362 L67431102 + K7051002
L67053001 Single Solenoid, Valve only, with fluorocarbon O-rings, 115VAC / 60Hz N/A N/A
L67053002 Single Solenoid, Valve only, with spring return K352124 L67539102 + voltage
L67053005 Single Solenoid, Valve only, with NC pilot using adapters K352124 N/A
L67053007 Single Solenoid, Valve only, with blank end spacers K352124 N/A
L67053008 Single Solenoid, Valve only, with blank end spacers K352124 N/A
L67053009 Single Solenoid, Valve only, with blank end spacers, 120VAC K352124 N/A
SK200 3/8"
Specials Description Repair Kit Closest Replacement
L67053010 Single Solenoid, Valve only, with stainless steel spool K352124 N/A
L67053011 Single Solenoid, Valve only, with 3-pin Brad Harrison connector K352124 L67539102 + voltage
L67053012 Single Solenoid, Valve only, with 3-pin Brad Harrison connector K352124 L67539102 + voltage
L67053013 Single Solenoid, Valve only, with high temperature seal and coil N/A N/A
less shockpad
L67053014 Single Solenoid, Valve only, with fluorocarbon O-rings N/A N/A
L67053015 Single Solenoid, Valve only, with internal exhaust drilling K352124 N/A
L67053016 Single Solenoid, Valve only, with blank spacer at inlet K352124 N/A
L67053017 Single Solenoid, Valve only, with gasket plate K352124 L6753910453
L67053018 Single Solenoid, Valve only, with 75VDC coil K352124 N/A
L67053019 Single Solenoid, Valve only, with 125VDC coil K352124 L6753210261
L67053020 Single Solenoid, Valve only, with 32VDC coil K352124 N/A
L67053021 Single Solenoid, Valve only, with special spring return override K352124 L6753910253
L67053023 Single Solenoid, valve only, with fluorocarbon O-rings N/A N/A
L67053024 Single Solenoid, valve only, with JIC pilot valve K352124 N/A
L67053025 Single Solenoid, valve only, with high temperature seal and coil, N/A N/A
external pilot
L67053027 Single Solenoid, valve only, with blank spacer at inlet, 24VDC K352124 N/A
L67053028 Single Solenoid, valve only, with blank end spacers, 24VDC K352124 N/A
L67053029 Single Solenoid, valve with base, with high temperature seal and coil, 24VDC N/A N/A
L67053030 Single Solenoid, valve with base, with high temperature seal and coil, 120VAC N/A N/A
L68044001 Double Remote Pilot, inline valve, with special air bleed remote adapters K352355 N/A
L68054001 Double Solenoid, inline valve, with high temperature seals and coil, N/A N/A
NEMA 4, 120VAC
L68054002 Double Solenoid, inline valve, with stainless steel spool, 120VAC K352126 N/A
L68054003 Double Solenoid, inline valve, with stainless steel spool, 24VDC K352126 N/A
L68054004 Double Solenoid, inline valve, with stainless steel spool, 120VAC K352126 N/A
L68054005 Double Solenoid, inline valve, with high temperature seals N/A N/A
L68054006 Double Solenoid, inline valve, with high temperature seals and coil, N/A N/A
NEMA 4, 120VAC
L69043001 Double Remote Pilot, inline valve, with special drilling in body K352355 N/A
L69044001 Double Remote Pilot, inline valve, with special drilling in body K352355 N/A
L69053001 Double Solenoid, inline valve, with stainless steel spool K352126 N/A
L69054001 Double Solenoid, inline valve, with class “H” coil, 120VAC K352126 N/A
L69054002 Double Solenoid, inline valve, with hazardous duty solenoid K352126 L69543721 + voltage
L69054003 Double Solenoid, inline valve, with two NC solenoids and adapter K352126 N/A
L69054004 Double Solenoid, inline valve, with speed controls K352126 L6954321553 + flow controls
L70044001 Single Remote Pilot, inline valve, with fluorocarbon O-rings N/A N/A
L70044002 Single Remote Pilot, inline valve, with offset spring K352362 L70441102
L70053001 Single Solenoid, inline valve, with stainless steel spool K352124 N/A
L70053003 Single Solenoid, inline valve, with suppressors K352124 L70539102 + voltage
L70053004 Single Solenoid, inline valve, with 32VDC coil, and special service gasket K352124 N/A
L70053005 Single Solenoid, inline valve, with 250VDC coil K352124 N/A
L70053006 Single Solenoid, inline valve, with special grease and hydraulic gasket N/A N/A
L70054001 Single Solenoid, inline valve, with 48VDC coil, class “H” coil, N/A N/A
fluorocarbon O-rings
L70054002 Single Solenoid, inline valve, with 48VDC coil, class “H” coil, N/A N/A
fluorocarbon O-rings
L70054003 Single Solenoid, inline valve, with class “H” coil, fluorocarbon O-rings N/A N/A
L70054004 Single Solenoid, inline valve, with suppressors K352124 L70549102 + voltage
L70054005 Single Solenoid, inline valve, with stainless steel spool K352124 N/A
L70054006 Single Solenoid, inline valve, with class “H” coil, and special name tag K352124 N/A
L70054007 Single Solenoid, inline valve, with 48 inch leads K352124 L7054610257
L70054008 Single Solenoid, inline valve, with fluorocarbon O-rings and 48VDC coil N/A N/A
L70054009 Single Solenoid, inline valve, with fluorocarbon O-rings N/A N/A
L70054010 Single Solenoid, inline valve, Nema 4 solenoid with 24VDC class “B” coil N/A N/A
SK200 1/2"
Specials Description Repair Kit Closest Replacement
L51045001 Double Remote Pilot, less base, with sequence timer K352358 L51451102 + timer
L51045002 Double Remote Pilot, less base, with air bleed K352358 N/A
L51055001 Double Solenoid, less base, with special lubrication N/A N/A
L51055002 Double Solenoid, less base, with blocked exhaust ports K352153 N/A
L51055003 Double Solenoid, less base, with aluminum spool K352153 N/A
L51055004 Double Solenoid, less base, with light 240VAC K352153 L5155310257
L51055005 Double Solenoid, less base, with remote pilot adapter K352153 N/A
L51055006 Double Solenoid, less base, with one remote pilot adapter K352153 N/A
L51055007 Double Solenoid, less base, with drilled internal pilot supply K352153 N/A
L51055009 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L51055010 Double Solenoid, less base, with stainless steel spool K352153 N/A
L51055011 Double Solenoid, less base, less pilot K352153 L51451102
L51055012 Double Solenoid, less base, with special override K352153 L5155910253
L51055013 Double Solenoid, less base, with special plate to raise pilot K352153 N/A
L52055001 Double Solenoid, less base, lubricated for non-lube service N/A N/A
L52055002 Double Solenoid, less base, with remote adapter K352153 N/A
L52055004 Double Solenoid, less base, with lead sealing agent K352153 L52553221 + voltage
L52055005 Double Solenoid, less base, with 230VDC coil K352153 N/A
L52055006 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L52055007 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L52055008 Double Solenoid, less base, with conduit connection and K352153 N/A
Brad Harrison connector
L52055009 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L52055010 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055011 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055012 Double Solenoid, less base, with stainless steel spool K352153 N/A
L52055013 Double Solenoid, with base, with 5-pin connector in base K352153 L5255921153
L52055014 Double Solenoid, less base, with blank exhaust spacers K352153 N/A
L54055001 Single Solenoid, less base, lubricated with special grease N/A N/A
L54055002 Single Solenoid, less base, with special coated spool K352152 N/A
L54055004 Single Solenoid, less base, with light for 240VAC K352152 L5455310257
L54055005 Single Solenoid, less base, with remote pilot adapter K352152 N/A
L54055006 Single Solenoid, less base, with shock pads K352152 L54558102 + voltage
L54055007 Single Solenoid, less base, with lead sealing agent K352152 L54553102 + voltage
L54055008 Single Solenoid, less base, with non-plug in pilot valve K352152 N/A
L54055009 Single Solenoid, less base, with NEMA 4 pilot K352152 N/A
L54055010 Single Solenoid, less base, with internal / external pilot supply convertibility K352152 L54554102 + voltage
L54055011 Single Solenoid, less base, with conduit connection and K352152 N/A
Brad Harrison connector
L54055014 Single Solenoid, less base, with conduit connection K352152 N/A
L54055015 Single Solenoid, less base, with stainless steel spool K352152 N/A
L54055016 Single Solenoid, less base, less pilot K352152 N/A
L54055017 Single Solenoid, less base, with raised electrical connection K352152 N/A
L61055001 Double Solenoid, inline, with drilled internal pilot exhaust K352153 N/A
L61055002 Double Solenoid, inline, with 50VAC / 50Hz coil K352153 N/A
L61056001 Double Solenoid, inline, with class “H” coil, 120VAC / 60Hz K352153 N/A
L62045001 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62046001 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62046002 Double Remote Pilot, inline, with special service gaskets K352358 N/A
L62056001 Double Solenoid, inline, with 75VDC coil K352153 N/A
SK200 1/2"
Specials Description Repair Kit Closest Replacement
L62056002 Double Solenoid, inline, with 48VAC / 50Hz coil K352153 N/A
L62056003 Double Solenoid, inline, with 75VDC coil K352153 N/A
L62056004 Double Solenoid, inline, with 37VDC coil K352153 N/A
L64046001 Single Remote Pilot, inline, with fluorocarbon seals N/A N/A
L64056004 Single Solenoid, inline, with class “H” coil, 115VAC / 60Hz K352151 N/A
Valvair II 1"
Specials Description Repair Kit Closest Replacement
L65058001 Double Solenoid, less base, with NC pilot K352130 N/A
L65058002 Double Solenoid, less base, with NC pilot and light K352130 N/A
L65058003 Double Solenoid, less base, with NC pilot K352130 N/A
L65058004 Double Solenoid, less base, with NC pilot K352130 N/A
L65058005 Double Solenoid, less base, with conduit operator connection K352130 N/A
L65058006 Double Solenoid, with base, with Brad Harrison connection in base K352130 L6558810253
L65058007 Double Solenoid, less base, with Brad Harrison connection in pilot K352130 N/A
L65058008 Double Solenoid, less base, less pilot K352130 L6558910253
L66058001 Double Solenoid, less base, with blank spacers at exhaust K352130 N/A
L66058002 Double Solenoid, less base, with one continuous duty solenoid K352130 N/A
L66058003 Double Solenoid, less base, with 75VDC coil K352130 N/A
L66058004 Double Solenoid, less base, with one remote pilot operator K352130 N/A
L66058005 Double Solenoid, less base, with special pilot K352130 N/A
L67058001 Single Solenoid, less base, with 120VAC class “H” coil and 10 foot leads K352128 N/A
L67058002 Single Solenoid, less base, with 4-pin connector in pilot K352128 N/A
L67058003 Single Solenoid, less base, with NEMA 4 JIC pilot K352128 N/A
A4 or A5
Specials Description Repair Kit Closest Replacement
A4C1A43Y001 Single Solenoid, inline valve, with fluorocarbon seals and K35020050 + K352366 L7054380453 - with Buna N seal
class H coil
A4C1A43Y002 Single Solenoid, inline valve, with fluorocarbon seals and K35020050 + K352366 L7054380453 - with Buna N seal
external pilot
A431A43Y001 Single Solenoid, with special non-locking override K352124 L7054510253
A431531Y001 Single Solenoid, with base, with 60VAC / 60Hz coil and K352124 N/A
BSPP ports
A431533Y001 Single Solenoid, with base, with 3-pin connector in base K352124 L6753910253 + K022090
A431543Y001 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910253 + K022091
external pilot
A431543Y002 Single Solenoid, with base, with special non-locking override K352124 L6753810253 + K022091
A431553Y001 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910253 + K022101
external pilot
A431553Y002 Single Solenoid, with base, with fluorocarbon seals and K35020050 + K352166 L6753910249 + K022101
external pilot
A441VXXY001 Double Solenoid, less base, with anodized body K352126 L6553210257
A441533Y001 Double Solenoid, with base, with 3-pin connector in base K352126 L6553910253 + K022090
A471553Y001 Single Remote Pilot, with base, with special pilot adapter K352362 L67431102 + K022101
A531A53Y001 Single Solenoid, inline valve, with 200 PSI pilot K352152 L6453210353
A531553Y001 Single Solenoid, with base, with 200 PSI pilot K352152 L5455210353 + K022093