1. The drawing shows reinforcement details for column foundations and columns. 2. All dimensions are in millimeters unless otherwise noted. It specifies reinforcement sizes and spacing for column foundations and columns. 3. Written dimensions take precedence over scaled dimensions and any deviations from structural drawings must be brought to the notice of the structural consultant before execution.

Uploaded by

Nimitesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views

Untitled

1. The drawing shows reinforcement details for column foundations and columns. 2. All dimensions are in millimeters unless otherwise noted. It specifies reinforcement sizes and spacing for column foundations and columns. 3. Written dimensions take precedence over scaled dimensions and any deviations from structural drawings must be brought to the notice of the structural consultant before execution.

Uploaded by

Nimitesh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 29

1 2 3 4 5 6 7 8 9 10 11 12 1.

THE DRAWING SHALL BE READ IN


CONJUNCTION WITH RELEVANT ARCH.
DRAWINGS AND SPECIFICATIONS.
2. ALL DIMENSIONS ARE IN MILLIMETER
525 525 UNLESS OTHERWISE STATED.
75 2650 75
1100 2375 1200 2300 2300 1200 2375 1100 2 -16# + 1 - 12# ON EACH FACE 3. ONLY WRTTEN DIMENSIONS ARE TO BE
[ TOTAL : 4 NOS 16#
4 NOS 12# ] FOLLOWED & THE DRAWIHGS ARE NOT
TO BE SCALLED
1562

F1 F1 F1 F1 4. DEVIATIONS IF ANY TO THE STRUCTURAL


F2 F2
DRA`WINGS SHALL BE BROUGHT TO THE
A NOTICE OF THE STRUCTURAL
C1 C1 C1 C1 CONSULTANT BEFORE EXECUTION.
C1 C1 400
8# BINDERS
@ 170 C/C 5. GRADE OF R.C.C SHALL BE M-25
2900

6. REINFORCEMENT SHALL BE HIGH


F1 F1 F1 F1 STRENGTH DEFORMED BAR OF GRADE
F2 F2
250 Fe:415/500 CONFORMING TO IS:1786-1985.
B
C1 C1 C1 C1 7. CLEAR COVER TO MAIN REINFORCEMENT
C1 C1 COLUMN TYPE - C1
SHALL BE AS FOLLOWS .
2650

FOOTING = 50mm
COLUMNS = 40mm
F1 F1 F1 F1 FLOOR/ROOF BEAMS = 25mm
C F2 F2
75

SLABS = 20mm
3 -12# ON EACH FACE
[ TOTAL : 8 NOS 12# ]
8. FINISHED GROUND LEVEL HAS BEEN
D C2 C1 C1 C1 C1 C2
CONSIDERED ± 0 MM/ FEET.
9. IT IS DESIGNED FOR G + 1 STRUCTURE.
2875

F1 F1 10. UNLESS NOTED OTHERWISE THE MIN.


400 LAP/ DEVELOPMENT LENGTH OF BARS
E 8# BINDERS
@ 170 C/C OF DIAMETER 'D' SHALL BE AS
F2 F1 F1 F2 FOLLOWS.
F
800
75

C1 C1
11. Plot Size 17800 x 12500
G C2 C1 C1 C2
1562

250
COLUMN TYPE - C2
DEFORMED BARS
NGL CONCRETE
LAYOUT PLAN OF FOOTING & COLUMN GRADE TENSION COMPRESSION
M-25 50 D 38 D
P
1 X 1
Education Purpose Only
100 100
1500 signature signature
d2
PROJECT CONSULTANT :-
d1
ARCHITECT :-
PCC 1:3:6 100 signature of (ARCHITECT)
SAND FILLING 100
Y Education Purpose Only
SECTION 1-1 RA & RB ISOLATED FOOTING SCHEDULE signature of (STRUCTURAL ENGINEER) .
TRAPEZOIDAL FOOTING PLAN
FOOTING FOOTING SIZE REINFORCEMENT
MARK A B d1 d2 RA RB Project Title:-
PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE - II & PHASE -III
F1 1800 1800 250 150 12 @150 c/c 12 @150 c/c Drawing Title:-
LAYOUT PLAN OF COLUMNS
& FOOTINGS FOR 2BHK QUARTER
SCALE
F2 1500 1500 200 100 12 @170 c/c 12 @170 c/c DATE DRN BY STR. DESIGN. DRG. NO.
SS/2BHK/ST/01

REV.
0
NOTES:
2050
GB4 GB4 1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
OTHERWISE SPECIFIED
2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
TO BE FOLLOWED
3400
1500 GB3 GB3 GB3 GB3
3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
GB2 GB4 2400 GB4 GB2 CONSULTANT BEFORE COMMENCEMENT OF WORK.
4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
OF PRACTICE
GB16 5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
ARCH . DRGS
6. PROVIDING SLAB HEIGHT 3000 mm
2500 7. N.G.L TO PLINTH LEVEL HEIGHT IS 900 mm
GB1 GB1 GB1 GB1 GB1 GB1 8. SIZE OF BEAM = 250 mm x 300 mm
GB2 GB4 GB4 GB2
GB16 5-12#(3+2)
2200 PB16
2250 GB15
2400 300 8# 2LG. ST.
GB15 /PB15
GB5 GB14 GB5 GB5 GB14 GB5 @130C/C.
/PB15
3-12#
250
GB13 GB9 GB16 GB9 GB13
2400 BEAM SIZE
2500
SIGNATURE:- SIGNATURE:-
3500 2550 GB8 GB8
3350 GB7 GB7
GB6 GB6 PROJECT CONSULTANT :- SIGNATURE:-
GB16
ARCHITECT :- SIGNATURE:-
GB12 GB9 GB9 GB12
3250
GB10 1600 GB10
800 GB11 GB11
2650 PROJECT TITLE :-
GB9 GB9 PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE -II & PHASE -III
DRAWING TITLE :-
GROUND BEAM LAYOUT PLAN
WORKING DRAWING
(2 BHK STAFF QUARTER)
GROUND BEAM LAYOUT PLAN SCALE DRAWING NO:
SS/2BHK/AR/01
REVISION: DATE: REMARKS:
0 WORKING DRAWING
NOTES:
1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
OTHERWISE SPECIFIED
2050 2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
TO BE FOLLOWED
1250 A3 A3 3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
CONSULTANT BEFORE COMMENCEMENT OF WORK.
4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
OF PRACTICE
5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
ARCH . DRGS
3400 2050 2400 3400 6. PROVIDING SLAB HEIGHT 3000 mm
7. N.G.L TO PLINTH LEVEL HEIGHT IS 900 mm
2800 2800 2800 8. SIZE OF BEAM = 250 mm x 300 mm
A1 A2 3450 A9 A2 A1
2200 5-12#(3+2)
3250
1075 A4 A4
2400
2400 A5 A5 300 8# 2LG. ST.
1750 A10 @130C/C.
A4 A4
3-12#
250
2800 3250 2400
BEAM SIZE
SIGNATURE:- SIGNATURE:-
2700 A7 2700
A11 A7
3500 A6 A6 PROJECT CONSULTANT :- SIGNATURE:-
ARCHITECT :- SIGNATURE:-
3250
1350 A8 A8
PROJECT TITLE :-
PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE -II & PHASE -III
DRAWING TITLE :-
PLINTH FILLING
WORKING DRAWING
(2 BHK STAFF QUARTER)
AREA FILLING SCALE DRAWING NO:
SS/2BHK/AR/02
REVISION: DATE: REMARKS:
0 WORKING DRAWING
1. OUTER WALL 200MM THICK NOTES:
2. INNER WALL 100MM THICK 1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
OTHERWISE SPECIFIED
3. PROVIDING RATIO OF MOTAR 2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
TO BE FOLLOWED
IN BRICK WORK MASONARY 1:4 3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
W = 2400 CONSULTANT BEFORE COMMENCEMENT OF WORK.
SS HANDRAIL R = 150 SS HANDRAIL 4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
T = 250 OF PRACTICE
Chhajja Chhajja Chhajja Chhajja 5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
1100 x 600 1100 x 600 BALCONY BALCONY 1100 x 600 1100 x 600 ARCH . DRGS
2550 x 1500 2550 x 1500 6. THIS DRAWINGS IS THE SOLE PROPERTY OF M/s THE
14800 DESIGN GROUP AND SHOULD NOT BE COPIED IN WHOLE/
1500 1500 PART
7. PROVIDING SLAB HIGHT 3Mtr
D2 D2
SIZES OF DOORS & WINDOWS IN METER
W2 W2 W2 W2 W2 W2 Sl. Type Sill Lintel
Sizes Descriptions
2400 No. Ht. Ht.
W1
50 KITCHEN W1 1 MD 1.20 x 2.1 00 2.10 Single leaf door as/ detail
10 2100 x 3000
Chhajja MASTER BEDROOM
1175 1175 Chhajja 2 D1 1.05 x 2.1 00 2.10 Single leaf door as/ detail
KITCHEN 9 11 MASTER BEDROOM
1700 x 600 3600x3000 2100 1700 x 600
2100 x 3000 8 12
3600x3000 3 D2 0.9 x 2.1 00 2.10 Single leaf door as/ detail
7 13
6 14 4 D3 0.75 x 2.1 00 2.10 Single leaf frp door as/ detail
2250 5 15 5 W1 1.5 x 1.2 0.90 2.10 Window as/ detail
D2 D2
4
3
16
D2 D2 5700 6
W2 0.9 x 1.2 0.90 2.10 Window as/ detail
17
2 18 7 V1 0.35x 0.35 Ventilator as/detail
D3 1 19
D3
TOILET TOILET
STAIRCASE
2400 x1200 UP 2400 x 3500 2400 x1200
V1 V1 P.L.
SECTION A-A
TOILET 2250
2400 x1200 D3 D3
1200 HALL TOILET
2400 HALL CORRIDOR 3300 x 5250 2400 x1200
V1 600 900
150
V1 3300 x 5250 2400 x 3700
250
Chhajja
1100 x 600 W2 D1 D1 W2
1050 Chhajja
D2 D2
1100 x 600 NGL
B B 1500
400 MD 600 BEDROOM
3000 x 3600
BEDROOM
3600 4000
3000 x 3600
600 1300
W1 W1
3000 100 125
A Chhajja 600
Chhajja 1100 D1 D1
W2 W2
1100 x 600
800
3500 3500 1100 x 600 Chhajja
W1 W1
BALCONY BALCONY 200
3700 x1600 3700 x1600
2400
3300 W = 2400 3300
Chhajja A Chhajja PROJECT TITLE :-
SS HANDRAIL R = 150 SS HANDRAIL
T = 250
1700 x 600 1700 x 600 PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE -II & PHASE -III
DRAWING TITLE :-
GROUND FLOOR PLAN
WORKING DRAWING
(2 BHK STAFF QUARTER)
GROUND FLOOR PLAN SCALE DRAWING NO:
SS/2BHK/AR/03
REVISION: DATE: REMARKS:
0 WORKING DRAWING
1. THE DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT ARCH.
DRAWINGS AND SPECIFICATIONS.
2. ALL DIMENSIONS ARE IN MILLIMETER
GB2 GB4 GB4 GB2 UNLESS OTHERWISE STATED.
200 3. ONLY WRTTEN DIMENSIONS ARE TO BE
FOLLOWED & THE DRAWIHGS ARE NOT
TO BE SCALLED
4. DEVIATIONS IF ANY TO THE
STRUCTURAL
DRA`WINGS SHALL BE BROUGHT TO THE
NOTICE OF THE STRUCTURAL
GB1 GB1 GB1 GB1 GB1 GB1 CONSULTANT BEFORE EXECUTION.
5. GRADE OF R.C.C SHALL BE M-25
GB2 GB4 GB2
GB4
4-10#
GB5
GB14 GB15 GB14
GB5 GB15 GB5 GB5 200 8# 2LG. ST.
@130C/C.
GB13 GB13 x
(Wall Width)
GB8 GB16 GB8 GB7 LINTEL BEAM
GB7 (200mm x 200mm)
GB6 2400 GB6
(100mm x 200mm)
GB12 GB9 GB9 GB12
signature of (STRUCTURAL ENGINEER) .
LAYOUT PLAN OF LINTEL BEAM Project Title:-
PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE -II & PHASE -III
Drawing Title:-
LAYOUT PLAN OF FLOOR BEAM & DET.
FOR 2BHK QUARTER
SCALE DATE DRN BY DRG. NO. REV.
SS/2BHK/AR/04 0
1. THE DRAWING SHALL BE READ IN
CONJUNCTION WITH RELEVANT ARCH.
DRAWINGS AND SPECIFICATIONS.
2. ALL DIMENSIONS ARE IN MILLIMETER
UNLESS OTHERWISE STATED.
SB4 SB4
3. ONLY WRTTEN DIMENSIONS ARE TO BE
FOLLOWED & THE DRAWIHGS ARE NOT
TO BE SCALLED
SB3 SB3 SB3 SB3 4. DEVIATIONS IF ANY TO THE
STRUCTURAL
SB2 SB4 SB4 SB2 DRA`WINGS SHALL BE BROUGHT TO THE
NOTICE OF THE STRUCTURAL
CONSULTANT BEFORE EXECUTION.
SB16
5. GRADE OF R.C.C SHALL BE M-25
6. REINFORCEMENT SHALL BE HIGH
STRENGTH DEFORMED BAR OF GRADE
SB1 SB1 SB1 SB1 SB1 SB1 Fe:415/500 CONFORMING TO IS:1786-1985.
7. CLEAR COVER TO MAIN
REINFORCEMENT
SB2 SB4 SB4 SB2 SHALL BE AS FOLLOWS .
COLUMNS = 40mm
FLOOR/ROOF BEAMS = 25mm
SB16 SLABS = 20mm
2-12#
SB14 SB15 SB15 SB14
SB5 SB5 SB5 SB5
350 8# 2LG. ST.
@130C/C.
SB13 SB9 SB16 SB9 SB13
4-12#
250
SB8 SB16 SB8
SB7 SB7
SLAB BEAM SIZE
SB6 SB6 (250mm X 350mm)
SB16
SB12 SB9 SB9 SB12
signature signature
SB10 SB10
SB11 SB11 PROJECT CONSULTANT :- signature of (CREDA)
SB9 SB9 ARCHITECT :-
signature of (ARCHITECT)
signature of (STRUCTURAL ENGINEER) .
SLAB BEAM LAYOUT Project Title:-
Drawing Title:-
LAYOUT PLAN OF FLOOR BEAM & DET.
FOR 2BHK QUARTER
SCALE DATE DRN BY DRG. NO. REV.
NTS B.M. SS/2BHK/AR/05 0
NOTES:
1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
OTHERWISE SPECIFIED
2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
TO BE FOLLOWED
3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
W = 2400 CONSULTANT BEFORE COMMENCEMENT OF WORK.
SS HANDRAIL R = 150 SS HANDRAIL 4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
T = 250 OF PRACTICE
Chhajja Chhajja Chhajja Chhajja 5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
1100 x 600 1100 x 600 BALCONY BALCONY 1100 x 600 1100 x 600 ARCH . DRGS
2550 x 1500 2550 x 1500 6. THIS DRAWINGS IS THE SOLE PROPERTY OF M/s THE
14800 DESIGN GROUP AND SHOULD NOT BE COPIED IN WHOLE/
1500 1500 PART
7. PROVIDING SLAB HIGHT 3Mtr
D2 D2
W2 W2 W2 W2 W2 W2
2400 DIMENSION OF ROOMS/HALLS SHALL INCREASE.
W1
50 KITCHEN W1
10 2100 x 3000
Chhajja MASTER BEDROOM
1175 1175 Chhajja
3600x3000
KITCHEN 9 11 MASTER BEDROOM SIZES OF DOORS & WINDOWS IN METER
1700 x 600 8 12 2100 1700 x 600
2100 x 3000 3600x3000 Sl. Type Sizes Sill Lintel Descriptions
7 13 No. Ht. Ht.
6 14
2250 5 15 1 MD 1.20 x 2.1 00 2.10 Single leaf door as/ detail
4 16
D2 D2 3 17
D2 D2 5700 2 D1 1.05 x 2.1 00 2.10 Single leaf door as/ detail
2 18
D3 D3 3 D2 0.9 x 2.1 00 2.10 Single leaf door as/ detail
1 19
TOILET TOILET 4 D3 0.75 x 2.1 00 2.10 Single leaf frp door as/ detail
STAIRCASE
2400 x1200 UP 2400 x 3500 2400 x1200 2.10 Window as/ detail
V1 V1 5 W1 1.5 x 1.2 0.90
6 W2 0.9 x 1.2 0.90 2.10 Window as/ detail
TOILET 2250 7 V1 0.35x 0.35 Ventilator as/detail
2400 x1200 D3 D3
1200 HALL TOILET
2400 HALL CORRIDOR 3300 x 5250 2400 x1200
V1 600
V1 3300 x 5250 2400 x 3700 1. OUTER WALL 200MM THICK
W2 D1 D1 W2
2. INNER WALL 100MM THICK
Chhajja 1050 Chhajja
3. PROVIDING RATIO OF MOTAR
D2 D2
1100 x 600 1100 x 600
400
IN BRICK WORK MASONARY 1:4
MD 600 BEDROOM
3000 x 3600
BEDROOM
3600 4000
SIGNATURE:- SIGNATURE:-
3000 x 3600
600 1300
3000
W1 W1
Chhajja PROJECT CONSULTANT :- SIGNATURE:-
Chhajja 1100 W2 D1 D1 W2 1100 x 600
1100 x 600
W1 800 BALCONY W1
BALCONY
3700 x1600 200 ARCHITECT :-
3700 x1600 SIGNATURE:-
3300
3300 PROJECT TITLE :-
Chhajja SS HANDRAIL SS HANDRAIL Chhajja
1700 x 600 1700 x 600 PROPOSED SAINIK SCHOOL COMPLEX
IN PHASE -II & PHASE -III
DRAWING TITLE :-
FIRST FLOOR PLAN GROUND FLOOR PLAN
WORKING DRAWING
(2 BHK STAFF QUARTER)
SCALE DRAWING NO:
SS/2BHK/AR/06
REVISION: DATE: REMARKS:
0 WORKING DRAWING
FACE
LEVEL - 3650
FACE
FACE FACE LEVEL+- 00 FACE FACE
LEVEL+ 2100 LEVEL+1300 LEVEL+ 1300 LEVEL+ 2100
2100
PARAPET
WALL +7900
1000
ROOF SLAB
LEVEL+6900
900
LINTEL
LEVEL +6000 600 600
1200
SILL
LEVEL +4800
900 FACE
LEVEL+ 2900
FACE
LEVEL+ 2900
G.F. SLAB FACE FACE
LEVEL +3900
LEVEL+ 2700 LEVEL+ 2700
900
LINTEL
LEVEL +3000 600 600
1200
SILL
LEVEL+1800
900
PLINTH
LEVEL +900
900
NGL +
- 00
SS HANDRAIL SS HANDRAIL
W = 2400
FACE R = 150
LEVEL+ 2800 T = 250
FRONT ELEVATION
FACE
LEVEL+- 00
FACE
LEVEL - 5700
FACE FACE
FACE
LEVEL+- 00 LEVEL - 5700
LEVEL+- 00
FACE
600 LEVEL+- 00 600
FACE FACE
LEVEL LEVEL
+ 600 + 600
600 600
FACE
LEVEL
+ 1500
BACK SIDE ELEVATION
14800
2550 2550
1200 2400
1200
600
1800

1800
TOWER BRICK WORK
TOWER + 9000 + 9200
4200
600 600
3200

9700
600
TERRACE + 6900
1200

1200
1200

+ 900 1200
+ 750
+ 600
+ 450
600

600
800
+ 300
+ 150
1800 1800
W = 2400
+ 6150 R = 150 + 6150
T = 250
NGL +- 00 NGL +- 00
TOP VIEW PLAN
X
Slab Level
2400
Slab Beam 1200
(250 x 350)
Mid-Landing
150 Beam
(250 x 300)
Landing
Waist slab 1200 250
300
(250)
Tread
(150)
Riser Waist slab
150
Plinth Level
250
300
250
Staircase 1175
50
Plinth Beam
(250 x 300)
Section X - X Plan
X
W = 2400 NOTES:
SS HANDRAIL R = 150 SS HANDRAIL
T = 250
Chhajja Chhajja Chhajja Chhajja 1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
BALCONY BALCONY OTHERWISE SPECIFIED
1100 x 600 1100 x 600 1100 x 600 1100 x 600 2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
2550 x 1500 2550 x 1500
14800 TO BE FOLLOWED
1500 1500 3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
CONSULTANT BEFORE COMMENCEMENT OF WORK.
4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
D2 D2 OF PRACTICE
5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
W2 W2 W2 W2 W2 W2 ARCH . DRGS
2400 6. THIS DRAWINGS IS THE SOLE PROPERTY OF M/s THE
1250 50 KITCHEN
DESIGN GROUP AND SHOULD NOT BE COPIED IN WHOLE/
W1 W1 PART
10 2100 x 3000 7. PROVIDING SLAB HIGHT 3Mtr
Chhajja MASTER BEDROOM 1175 1175 Chhajja
KITCHEN 9 11 MASTER BEDROOM
1700 x 600 3600x3000 8 12 2100 1700 x 600
2100 x 3000 3600x3000
7 13
DIMENSION OF ROOMS/HALLS SHALL INCREASE.
6 14
2250 5 15
D2 D2
4
3
16
D2 D2 5700
17
2 18 SIZES OF DOORS & WINDOWS IN METER
D3 1 19
D3 Sl. Type Sill Lintel
Sizes Descriptions
TOILET TOILET No. Ht. Ht.
STAIRCASE
2400 x1200 UP 2400 x 3500 2400 x1200
V1 V1 1 MD 1.20 x 2.1 00 2.10 Single leaf door as/ detail
2 1.05 x 2.1 00 2.10 Single leaf door as/ detail
TOILET 2250
D1
2400 x1200 D3 D3 0.9 x 2.1 00 2.10
3 D2 Single leaf door as/ detail
1200 HALL TOILET
2400 HALL CORRIDOR 3300 x 5250 2400 x1200
V1 600 4 D3 0.75 x 2.1 00 2.10 Single leaf frp door as/ detail
V1 3300 x 5250 2400 x 3700 5 W1 1.5 x 1.2 0.90 2.10 Window as/ detail
6 0.9 x 1.2 0.90 2.10 Window as/ detail
W2
W2 D1 D1 W2
Chhajja 1050 Chhajja 7 V1 0.35x 0.35 Ventilator as/detail
D2 D2
1100 x 600 1100 x 600
400 MD 600 BEDROOM
P.L.
3000 x 3600
BEDROOM
3600 4000
3000 x 3600 Entrance Passage
1300 2400 x 1300
600 3000
W1
A
W1 150
Chhajja 1100 D1 D1
Chhajja 900
W2 3500 3500 W2 1100 x 600
1100 x 600
W1 800 W1
250
BALCONY BALCONY 200
3700 x1600 3700 x1600
NGL
2400 1500
3300 W = 2400 3300
Chhajja A R = 150 Chhajja SECTION A-A
T = 250
1700 x 600 1700 x 600
FLOORING DETAILS OF GROUND & FIRST FLOOR SECTION OF ENTRANCE STEP
SL. SPACE FLOORING DADO SL. SPACE FLOORING DADO PROJECT TITLE :-
No. No.
SPACIFICATION SPACIFICATION PROPOSED SAINIK SCHOOL COMPLEX
SPACIFICATION MAKE MAKE SPACIFICATION MAKE MAKE
IN PHASE -II & PHASE -III
1. Front & Rear 600mm x 600mm Kota Stone Skirting upto 4. Entrance Step Double Piece Granite LAKHA RED/ Double Piece Granite LAKHA RED/ DRAWING TITLE :-
Balcony --------------------- --------------------- (1200 x 250)each on Tread SHAHI RED (1200 x 150)each on Riser SHAHI RED GROUND FLOOR PLAN
Kota Stone Flooring 150mm High
WORKING DRAWING
5. Window Sill &
2. Staircase Below, 600mm x 600mm Sahara Group -IV Glossy Vitrified Skirting Sahara Group -IV Single Piece Granite Stone LAKHA RED/ --------------------- (2 BHK STAFF QUARTER)
Hall, Bed Room & Vitrified Flooring Multi of Multi Charge Door Sill ( Threshold ) SHAHI RED ---------------------
Up to 150mm High of Multi Charge
Corridor, Entrance Charged Full Body Mat Finish (300mm x 300mm) (300mm x 300mm) Ceramic Crystal Peach, Paper SCALE DRAWING NO:
6. Toilet Antiskid Tile
Passage. Ceramic Tile Flooring Glazed Wall Tile Dado upto Cut edge
2100mm High SS/2BHK/AR/09
3. 600mm x 600mm Sahara Group -IV (300mm x 300mm) Ceramic Crystal Peach, Paper
Kitchen Vitrified Flooring Multi of Multi Charge Glazed Wall Tile Dado upto Cut edge 7. Staircase & Single Piece Granite Stone LAKHA RED/ (300mm x 300mm) Ceramic Crystal Peach, Paper REVISION: DATE: REMARKS:
Charged Full Body Mat Finish 2100mm High SHAHI RED Glazed Wall Tile Dado upto Cut edge
Staircase Landing 900mm High
0 WORKING DRAWING
NOTES:
150
1. ALL DIMENSIONS ARE IN MILIMETER UNLESS AND
300 450 OTHERWISE SPECIFIED
255
125X75 SAL WOOD FRAME VERTICAL WOOD
125
75X62.5mm FRP OUTER DOOR 2. DRG SHOULD TO BE SCALED & WRITTEN DIMENSION ARE
506 175 FRAME TO BE FOLLOWED
120 250 100 250 150 GRAINS 3. DISCRIPANCY IF ANY SHALL BE CLARIFIED FROM THE
12mm X 12mm CORBELLED 125 x 75 SAL 175 75 175 100
CONSULTANT BEFORE COMMENCEMENT OF WORK.
BEADING WOOD FRAME
HORIZONTAL WOOD 4. ALL DETAILS SPECIFICATION S SHALL BE AS PER IS CODE
545 100 100
OF PRACTICE
506 GRAINS ALTERNATE 5. FOR OTHER DETAILS REFER STRUCTRAL AND OTHER
2100 150
300mm HEAVY DOOR 655
ARCH . DRGS
175
HANDEL 2100 300 mm HEAVY BRASS 150MM BRASS C.P TYPE
2100
HEAVY SLIDING DOOR 40 THK. FLUSH C.P DOOR HANDLE HANDLE
175
255
BOLT DOOR 506
HEAVY SLIDING 150 mm LONG BRASS C.P
120 900 WITH TEAK PLY DOOR BOLT TOWER BOLT
S S
255
VENEERING 657
VERTICAL GRAIN
506
150
75 75
DOOR STOPPER
DOOR STOPPER 150
30MM TK.FRP DOOR SIZES OF DOORS & WINDOWS IN METER
FRONT ELEVATION DOOR D1 Sl. Type Sizes Sill Lintel Descriptions
150 x 35 T.W
FRONT ELEVATION DOOR D2 FRONT ELEVATION DOOR-D3 No. Ht. Ht.
vertical style 1 D1 1.05 x 2.1 00 2.10 Single leaf door as/ detail
125 x 75 SAL 100 x 35 T.W
WOOD FRAME middle section 30 MM TK. FRP 2 D2 0.9 x 2.1 00 2.10 Single leaf flush door as/ detail
HOLD FAST
B
HOLD FAST HINGES DOOR 3 D3 0.75 x 2.1 00 2.10 Single leaf frp door as/ detail
HOLD FAST
HOLD FAST M.S HOLD
4 MD 1.2 x 2.1 00 2.10 Single leaf Panel door as/ detail
75 900 75
750
FAST
B.K wall 125 x 75 SAL X 938
Plaster 75 125 x 75 SAL
A
WOOD FRAME 200 thk. B.K wall 125 x 75 SAL
75
WOOD FRAME 62.5
X 62.5
150 x 35 T.W Plastering WOOD FRAME
vertical style 40 mm VENEERED B.K.WALL 75X62.5 MM FRP
FLUSH DOOR
PLAN AT S S PLASTERING DOOR OUTER
PLAN AT R R FRAME
PLAN AT 4-4
900
250MM LONG 150
750
BRASS C.P TOWER 250MM LONG BRASS C.P TOWER 450 300 125 S.S ROBE HOOK
255
BOLT(BARREL BOLT(BARREL TYPE) 175
TYPE) 150 250 100 250 120
125X75 SAL
506
78x62.5mm FRP OUTER
175 75 175 100
WOOD FRAME 125 x 75 SAL DOOR FRAME
12mm X 12mm CORBELLED
BEADING 545 WOOD FRAME 100 100
150 200 mm BRASS 506 655
300mm HEAVY DOOR HANDEL 150MM BRASS C.P TYPE
C.P HANDLE
2100 2100
175
HANDLE
BRASS C.P HEAVY SLIDING 300MM LONG BRASS VERTICAL WOOD
DOOR BOLT 255
C.P TOWER BOLT GRAINS 150 mm LONG BRASS C.P 175
506
120
TOWER BOLT
900
255
40 THK. FLUSH DOOR 900 30MM TK.FRP DOOR 657
WITH TEAK PLY VENEERING
150 506
DOOR MAGNETIC BUFFER
DOOR MAGNETIC SIGNATURE:- SIGNATURE:-
150
BUFFER BUFFER
BACK ELEVATION - D1 75 75
BACK ELEVATION - D2 BACK ELEVATION-D3
PROJECT CONSULTANT :- SIGNATURE:-
ARCHITECT :- SIGNATURE:-
150
250MM LONG 150
HINGES 255
125X75 SAL WOOD FRAME BRASS C.P TOWER
150x35mm thk. TEAK
BOLT(BARREL
255 PROJECT TITLE :-
WOOD SHUTTER FRAME
120 300 100 300 175
TYPE) 150 250 100 250 120
125X75 SAL
M.S hold fast 12mm X 12mm CORBELLED
BEADING WOOD FRAME
20 mm thk. T.W PANNEL 545
12mm X 12mm CORBELLED
12 mm x 12 mm BEADING 545
DRAWING TITLE :-
125
CORBELLED MOULDING 2100 150
300mm HEAVY DOOR 150
HANDEL 300mm HEAVY DOOR HANDEL DOOR DETAILS CARPENTRY
X 175
175 DRAWING OF 2 BHK STAFF QUARTER
Brick wall
125 x 75 SAL
WOOD FRAME
HEAVY SLIDING DOOR BRASS C.P HEAVY SLIDING
255
Plaster
BOLT DOOR BOLT 255
SCALE DELT BY: DRAWING NO:
DETAIL OF A
120 900
900 120
S S
1:50 LA
255
255
150 REVISION: DATE: REMARKS:
75 75
DOOR STOPPER DOOR MAGNETIC BUFFER
150
WORKING DRAWING
FRONT ELEVATION DOOR MD BACK ELEVATION - MD
0
REAR / BACK
14800
W2 W2 D2 W2 W2 D2 W2 W2
KITCHEN KITCHEN
W1 2100 x 3000 2100 x 3000 W1
MASTER BEDROOM MASTER BEDROOM
3600x3000 3600x3000
STAIRCASE
2400 x 3500
5700
D3 D2 D2 D2 D2 D3
TOILET TOILET
2400 x1200 2400 x1200
V1 V1
LEFT
RIGHT
TOILET D3 D3 TOILET
V1 2400 x1200 HALL HALL 2400 x1200 V1
3300 x 5250 CORRIDOR 3300 x 5250 600
2400 x 3700
W2 D1 D1 W2
D2 D2
MD
BEDROOM 2400 BEDROOM 4000
3000 x 3600 ENTRANCE 3000 x 3600
1300 PASSAGE 1300
2400 x 3700
W2 D1 W1 W1 D1 W2
3500 3500
800 800
W1 FRONT W1
3300
3300
PLASTERING WORK
10 mm M.S Sq. Bar (overlap) at Sq Bar / Rectangular Grid
10 mm M.S Sq. Bar (overlap)
35 x 5 35 x 5
at Sq Bar / Rectangular Grid
M.S Flat M.S Flat
Plate Plate
Hold Fastener Hold Fastener
35 x 5 100 35 x 5
100 100
M.S Flat Hold Fastener M.S Flat
Plate Hold Fastener
Plate
100
1200 1200
Hold Fastener Hold Fastener Hold Fastener Hold Fastener
1500 900
(W2) 900X1200
(W1) 1500X1200
M.S Flat
Plate 35 x 5
SIZES OF WINDOW S & VENTILATOR IN METER Hold Fastener
35 x 5
Type Sizes Sill Lintel Descriptions M.S Flat
Ht. Ht. Plate
W1 1.5 x 1.2 0.90 2.10 Window as/ detail
W2 0.9 x 1.2 0.90 2.10 Window as/ detail
V1 0.35x 0.35 ---- ---- Ventilator as/detail (V1) 350 X 350
Community Well Abstract
Sr. no Item Description Quantity Rate Per Amount
1 Excavation for foundation in earth, soil of all types, sand,
gravel and soft murum, including removing the excavated material
up to a distance of 50 m. beyond the building area and stacking and
spreading as directed, dewatering, preparing the bed for the
Foundation and necessary back filling, ramming, watering including
shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.)
By Manual Means

SSR Item no - 21.01


Reference No. BDA 1 147.844 239 Cu.m 35334.716

2 Excavation for foundation in hard murum including removing


the excavated material upto distance of 50 metres beyond
the building area and stacking and spreading as directed, dewatering,
preparing the bed for the foundation and necessary back filling,
ramming, watering including shoring and strutting etc. complete.
(Lift upto 1.50m) By Manual Means

SSR Item no - 21.05


Reference No. BDA 2 43.96 365 Cu.m 16045.4

3 Providing and laying Cast in situ/Ready Mix cement concrete in


M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding
/ steps including steel centering, formwork, laying/pumping,
compacting, roughening them if special finish is to be provided,
finishing uneven and honeycombed surface and curing etc. complete.
The Cement Mortar 1:3 plaster is considered for rendering uneven and
honeycombed surface, only. Newly laid concrete shall be
will not be allowed.),with fully automatic microprocessor based PLC
with SCADA enabled reversible Drum Type mixer/concrete Batch
mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)

SSR Item no - 24.04


Reference No. BDE 2 3.43 6359 Cu.m 21811.37

4 Providing second class Burnt Brick masonry with conventional/


I.S. type bricks in cement mortar 1:6 in foundations and plinth of
inner walls/ in plinth external walls including bailing out water manually ,
striking joints on unexposed faces, raking out joints on exposed
faces and watering etc. Complete

SSR Item no - 27.01


Reference No. BDG 1 21.74 7755 Cu.m 168593.7

5 Providing and laying in situ /Ready Mix cement concrete M-20 of trap
granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft,
strip foundations, grillage and footings of R.C.C. columns and steel
stanchions etc. including bailing out water, Steel centering formwork,
laying/pumping cover blocks, compaction and curing roughening the
surface if special finish is to be provided (Excluding reinforcement
and structural steel) etc. complete, with fully automatic micro processor
based PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)

SSR Item no - 25.11


Reference No. BDF 3 1.47 7104 Cu.m 10442.88
6 Providing and filling in the foundation with sand of approved
quality including watering, compacting etc. complete. (To be
executed with prior approval of Superintending Engineer)

SSR Item no - 21.39


Reference No. BDA 13 118.2 2160 Cu.m 255312

7 Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm


to 20 cm thick including hand packing and compacting etc. complete.

SSR Item no - 21.38


Reference No. BDA 12 5.202 1382 Cu.m 7189.164

8 Providing tuck pointing with cement mortar 1:3 for stone/Brick masonry
including scaffolding and curing etc. complete

SSR Item no - 32.18


Reference No. BDL 16 6.408 179 Cu.m 1147.032

9 Providing internal cement plaster 12mm thick in single coat


in cement mortar 1:4 without neeru finish to concrete or brick surfaces,
in all positions including scaffolding and curing etc. complete

SSR Item no - 32.04


Reference No. BDL 2A 68.766 278 Cu.m 19116.948
Community Well Estimate
Item no Description Nos Length (m) Width (m) Depth/Height (m) Unit Quantity Total Quantity

1 Earth work in Excavation


Excavation in foundation including
dewatering and disposal of the earth soil
of all the all types of soft murum

Initial Lift
a) Lift upto 0.2m
R₁ = 1.5+0.3+0.1+0.15+0.5+0.5+0.5
= 3.55
D₁ = 7.1m 1 39.591 2 Cu m. 79.182

b) Lift upto 2m-5m


R₂ = 1.5+0.1+0.15+0.5+0.5+0.3
= 3.05
D₂ = 6.1m 1 29.224 2 Cu m. 58.448

c) Lift upto 2m-5m


R₃ = 1.5+0.1+0.15+0.5+0.3
= 2.55
D₃ = 5.1m 1 20.428 0.5 Cu m. 10.214
147.844 Cu.m
2 Excavation in hard rock including
dewatering disposed of excavated
material as directed by engineer.

a) Lift upto 2m-5m


R₃ = 2.55
D₃ = 3.55 1 20.428 0.5 Cu m. 10.214

b) Lift upto 5m-8m


R₃ = 2.58
D₃ = 5.1 1 20.428 1 Cu m. 20.428

c) Lift upto 5m-8m


R₄ = 0.4+1.5+0.15 = 2.05
D₄ = 4.1 1 13.202 0.7 Cu m. 9.2414

d) Lift upto 5m-8m


R₅ = 1
D₅ = 2 1 3.141 1.3 Cu m. 4.0833
43.9667 Cu.m
3 P.C.C (1:2:4) Providing and laying (1:2:4)
curing, formwork etc complete

For bottom
a) External diameter
Rₑ = 1.5+0.4+0.15
= 2.05m
Dₑ = 4.1m

b) Internal diameter
Dᵢ = 3-0.15-0.15 = 2.7m 1 7.476 0.2 Cu m. 1.4952

b) 10mm thick P.C.C coping at top


Dₑ = 3.0+0.2+0.2
= 3.4m
Dᵢ = 3.0m 1 2.01 0.1 Cu m. 0.201

c) External diameter
Dₑ = 3+0.2+0.2+1.2+1.2
= 5.8m
Dᵢ = 3.4m 1 17.341 0.1 Cu m. 1.7341
3.4303 Cu.m
4 Providing and laying Burnt Brick
masonry in CM (1:6) including striking joints,
raking out joints,watering and
scaffolding etc complete.

a) Step 1
Dₑ = 3+0.4+0.4=3.8m
Dᵢ = 3m 1 4.272 1.8 Cu m. 7.6896

b) Step 2
Dₑ = 3+0.3+0.3=3.6m
Dᵢ = 3m 1 3.11 4 Cu m. 12.44

b) Step 3
Dₑ = 3+0.2+0.2=3.4m
Dᵢ = 3m 1 2.01 0.8 Cu m. 1.608
21.7376 Cu.m
5 Providing and laying in-situ M20 grade
of concrete including formwork,
scaffloding, curing etc complete

a) Ring 1
Dₑ = 3+0.4+0.4=3.8m
Dᵢ = 3m 1 4.272 0.2 Cu m. 0.8544

b) Ring 2
Dₑ = 3+0.3+0.3=3.6m
Dᵢ = 3m 1 3.11 0.2 Cu m. 0.622 1.4764 Cu.m

6 Providing reinforcement 2% of
concrete.
2% of item no.5 = 0.02 X 1.47 = 0.029
Weight = 0.029 X 78.5 = 2.27 2.27 Quintal

7 Refilling excavated material including


compaction upto 90% of standard
density

a) Step 1
R₄ = 2.05
Dₑ = 4.1
Dᵢ = 3.8 1 1.86 0.5 Cu m. 0.93

b) Step 2
Dₑ = 5.1
Dᵢ = 3.8 1 9.09 1.5 Cu m. 13.635

c) Step 3
Dₑ = 5.1
Dₑ = 3.4 1 11.34 0.5 Cu m. 5.67

d) Step 4
Dₑ = 6.1
Dᵢ = 3.6 1 19.04 2 Cu m. 38.08

d) Step 5
Dₑ = 7.1
Dᵢ = 3.6 1 29.41 1.7 Cu.m 49.997

d) Step 6
Dₑ = 7.1
Dᵢ = 2.9 1 32.98 0.3 Cu.m 9.894
118.206 Cu.m

8 Oversize filling providing in foundation


in P.C.C with murum boulder filling
voids with soft murum etc complete

External diameter
Dₑ = 5.80
Internal diameter 1 17.34 0.3 Cu.m 5.202
Dᵢ = 3.40 5.202 Cu.m

9 Pointing

External diameter
Dₑ = 3.4
Circumference
π X D = π X 3.4 = 9.42 1 10.68 0.6 Cu.m 6.408
6.408 Cu.m
10 Providing and laying 12mm thick
thick plaster in cement mortar 1:6
including scaffolding, curing etc

External diameter
Dₑ = 3.0
Circumference 1 9.42 7.3 Cu.m 68.766
π X D = π X 3 = 9.42 68.766 Cu.m
H = 2+2+2+0.7+0.6 = 7.3

11 Providing and casting in suit stones


wier half round drain 100mm dia
as per detailed drawing complete

D = 3+0.2+0.2+1.2+1.8-0.1-0.1-0.05-0.05
= 5.50
Circumference 1 17.27 17.27
π X D = π X 5.5 = 17.27 17.27 Sq.m

12 Providing and fixing M.S. pulley at


suitable places with fixing and
flooring etc complete. 2 2
2 Nos

13 Providing and fixing M.S. step at


suitable places and fixing in wall
finishing etc complete. 22 22
22 Nos
Serial No Practical Name Date Signature
Prepare the check list of items to be executed with units for
1 detailed estimate of the given structure from the given drawing.
Prepare a report on market rates for given material, labour wages,
hire charges of tools & equipments required to construct the given
2 structure as mentioned in at Serial number 1 above.
Prepare the detailed Specification for the given items using DSR
3 ( for any ten item).
Prepare the approximate estimate for the given civil engineering
4 works.
Prepare the approximate estimate for the given civil engineering
5 works.
Prepare bill of quantities of given item from actual
6 measurements, (any four items).
Prepare bill of quantities of given item from actual
7 measurements, (any four items).
Calculate the quantity of items of work from the given set of
drawings using standard measurement sheet for load bearing
residential structure using description of item from DSR (1BHK
8 Building with staircase).
Calculate the quantity of items of work from the given set of
drawings using standard measurement sheet for load bearing
residential structure using description of item from DSR (1BHK
9 Building with staircase).
Calculate the quantity of items of work from the given set of
drawings using standard measurement sheet for load bearing
residential structure using description of item from DSR (1BHK
10 Building with staircase).
Calculate the quantity of items of work from the given set of
drawings using standard measurement sheet for load bearing
residential structure using description of item from DSR (1BHK
11 Building with staircase).
Prepare detailed estimate from the given set of drawings using
“standard measurement and abstract format” for RCC framed
structure using description of item from DSR along with face
12 sheet and prepare quarry chart ,lead statement ( G+ l Building)
Prepare detailed estimate from the given set of drawings using
“standard measurement and abstract format” for RCC framed
structure using description of item from DSR along with face
13 sheet and prepare quarry chart ,lead statement ( G+ l Building) .
Prepare detailed estimate from the given set of drawings using
“standard measurement and abstract format” for RCC framed
structure using description of item from DSR along with face
14 sheet and prepare quarry chart ,lead statement ( G+l Building).
Prepare detailed estimate from the given set of drawings using
“standard measurement and abstract format” for RCC framed
structure using description of item from DSR along with face
15 sheet and prepare quarry chart ,lead statement ( G+l Building).
Prepare detailed estimate from the given set of drawings using
“standard measurement and abstract format” for RCC framed
structure using description of item from DSR along with face
16 sheet and prepare quarry chart ,lead statement ( G+l Building).
Calculate the reinforcement quantities from the given set of
drawings for a room size of 3 m X 4 m with bar bending schedule
17 (footing,column,beam,lintel with chajja, slab).
Calculate the reinforcement quantities from the given set of
drawings for a room size of 3 m X 4 m with bar bending schedule
18 (footing,column,beam,lintel with chajja, slab).
Calculate the reinforcement quantities from the given set of
drawings for a room size of 3 m X 4 m with bar bending schedule
19 (footing,column,beam,lintel with chajja, slab).
Calculate the reinforcement quantities from the given set of
drawings for a room size of 3 m X 4 m with bar bending schedule
20 (footing,column,beam,lintel with chajja, slab).
Calculate the reinforcement quantities from the given set of
drawings for a room size of 3 m X 4 m with bar bending schedule
21 (footing,column,beam,lintel with chajja, slab).
22 Prepare the rate analysis for the given five item of works.
23 Prepare the rate analysis for the given five item of works.
Prepare detailed estimate of W.B.M.Road of one kilometer
24 length from the given drawing.
Prepare detailed estimate of W.B.M.Road of one kilometer
25 length from the given drawing.
Prepare detailed estimate of small Septic tank from the given set
26 of drawings.
Prepare detailed estimate of small Septic tank from the given set
27 of drawings.
28 Prepare detailed estimate of well from the given set of drawing.
29 Prepare detailed estimate of well from the given set of drawing.
Use the relevant software to prepare detailed estimate of any one
30 of the WBM Road/Septic Tank/ well.
Use the relevant software to prepare detailed estimate of any one
31 of the WBM Road/Septic Tank/ well.
Use the relevant software to prepare detailed estimate of any one
32 of the WBM Road/Septic Tank/ well.
SR.NO. DESCRIPTION
QUANTITY RATE PER AMOUNT
Excavation for foundation in earth, soil of all types, sand, gravel
and soft murum, including removing the excavated material up
to a distance of 50 m. beyond the building area and stacking and
spreading as directed. dewatering, preparing the bed for the
1 foundation and necessary back filling, ramming, watering
including shoring and strutting etc, complete. (Lift upto 0.00 to
1.50 m.) By Manual Means
SSR. item no. 21.01
Reference no. BDA1 30.54 cu.m. 239 cu.mm ₹ 7,299.06
Providing and laying Cast in situ/Ready Mix cement concrete in
M-10 of trap/ granite/ quartzite gneiss metal for foundation and
bedding including bailing out water, Steel centering, formwork,
laying/pumping, compacting, roughening them if special finish is
to be provided, finishing if required and curing complete, with
2 fully automatic micro processor based PLC with SCADA enabled
reversible Drum Type mixer/concrete Batch mix plant (Pan
mixer) etc. complete With fine aggregate (Crushed sand VSI
Grade)
SSR item no.-21.01
Reference no-BDA1 1.728 cu.m. 5830 cu.m. ₹ 10,074.24
Providing second class Burt Brick masonry with conventional/ IS.
type bricks in cement mortar 1:6 in foundations and plinth of
inner walls/ in plinth external walls including bailing out water
3 manually, striking joints on unexposed faces, raking out joints on
exposed faces and watering etc. Complete
SSR item no.- 27.01
Reference no-BDG1 5.938 cu.m. 7755 cu.m. ₹ 7,755.00
Providing and constructing 200mm thick honey combed brick
4 work For soak-pit Including Scaffolding, watering and special
finishing If necessary curing etc. complete 3.204 cu.m. 3450 cu.m. ₹ 11,053.80
Providing second class Bumt Brick masonry with conventional/
IS. type bricks in cement mortar 16 in superstructure including
striking joints, raking out joints,watering and scaffolding etc
5
Complete
SSR item no.-27.06
Reference no-BDG7 1.215 sq.m. 1119 sq.m. ₹ 1,359.59
Providing and laying Cast in situ/Ready Mix cement concrete in
M15 of trap/ granite/quartzite/gneiss metal for bed blocks,
foundation blocks and such other items including bailing out
water, Steel centering, formwork, laying/ pumping. compacting,
roughening them if special finish is to be provided, finishing
uneven and honeycombed surface and curing etc. complete. The
Cement Mortar 1:3 plaster is considered for rendering uneven
6 and honeycombed surface only. Newly laid concrete shall be
covered by gunny bag, plastic, tarpaulin etc. (Wooden centering
will not be allowed.), with fully automatic micro processor based
PLC with SCADA enabled reversible Drum Type mixer/ concrete
Batch mix plant (Pan mixer) etc. complete. With fine aggregate
(Crushed sand VSI Grade)
SSR item no.-24.08
Reference no-BDEF
0.1305 cum. 6359 cu.m. ₹ 829.85

Providing and laying Cast in situ Ready Mix cement concrete in


M15 of

trap/ granite/quartzite/gneiss metal for bed blocks, foundation


blocks and such other items including bailing out water, Steel
centering, formwork, laying/ pumping, compacting, roughening
them if special finish is to be provided, finishing uneven and
7 honeycombed surface and curing etc. complete. The Cement
Mortar 1:3 plaster is considered for rendering uneven and
honeycombed surface only. Newly laid concrete shall be covered
by gunny bag, plastic, tarpaulin etc. (Wooden centering will not
be allowed), with fully automatic micro processor based PLC with
SCADA enabled reversible Drum Type mixer/ concrete Batch mix
plant (Pan mixer) etc. complete. With fine aggregate (Crushed
sand VSI Grade)
0.58 cu.m. 5830 cu.m. ₹ 3,381.40
Providing and fixing in position TMT FE-500 bar reinforcement of
various diameters for RCC pile caps, footings, foundations, slabs,
beams columns, canopies, staircase, newels, chajjas, lintels
8 pardis, copings, fins, arches etc as per detailed designs, drawings
and schedules including cutting, bending, hooking the bars,
binding with wires or tack welding and supporting as required
complete. 0.35 quintals 8970.3 quintals ₹ 3,139.61
Providing internal cement plaster 20mm thick in Single coats in
cement mortar 1:3
9
without neeru finish, to concrete, brick surface, in all positions
including scaffolding and curing etc. complete. 17.15 sq.m. 393 sq.m. ₹ 6,739.95
Providing and laying 100mm diameter iffluent pipe placed in lime
10
mortar with slope 1:4 joining etc, complete 7.55 m 350 m ₹ 2,642.50
Supplying and fixing 45 cm diameter C.I. manhole cover with
11
frame etc, complete 1 nos. 1050 no. ₹ 1,050.00
12 Providing and fixing 100mm x 100mm x 60mm sewer cover 2 nos. 2500 no. ₹ 5,000.00
providing and laying brick ballast of over size burnt brick kankar
13
for filling soak-pit 4.24 cu.m. 1750 cu.m. ₹ 7,420.00
14 Providing and fixing G.I. ventilator cowl on vent pipe. 1nos. 700 no. ₹ 700.00
15 Providing and fixing 75mm diameter vent pipe 3.1 m 350 m ₹ 1,085.00
SR.NO. DESCRIPTION NO. LENGTH WIDTH HEIGHT QUANTITY TOTAL QUANTITY
1 EXCAVATION IN ALL TYPE
OF SOIL.

a FOR SEPTIC TANK


H=1.885m 1 4.8 2.4 1.825 21.024
b FOR SOAKPIT
A=8.50 1 2.83 3 8.49
c FOR PIPE
L=2.65m 2 2.65 0.3 0.65 1.0335
30.54 cu.m.
2 P.C.C.(1:2:4) 1 4.8 2.4 0.15 1.728
1.728 cu.m.
3 SECOND CLASS BURNT
BRICK MASONRY FOR
a STEP-1
LONG WALL
L=4.5 2 4.5 0.4 0.45 1.62

SHORT WALL
L=1.3 2 1.3 0.4 0.45 0.468
b STEP-2
LONG WALL
L=4.3 2 4.3 0.3 0.525 1.3545

SORT WALL
L=1.3 2 1.3 0.3 0.525 0.4095
c STEP-3
LONG WALL
L=4.1 3 4.1 0.2 0.7 1.722

SHORT WALL
L=1.3 2 1.3 0.2 0.7 0.364
5.938 cu.m.
4 PROVIDING HONEYCOMB
BRICKWORK FOR SOAKPIT
A=1.068 1 1.068 3 3.204
3.204 cu.m.
5 SECOND CLASS HALF BRICK
THOCK MASONRY 1 0.9 1.35 1.215
1.215 sq.m.
6 PROVIDING CEMENT
CONCRETE(1:2:4) BED 1 2.9 0.9 0.05 0.1305
0.1305 cum.
7 PROVIDIND M20 GRADE
RCC WORK 1 0.8 0.9 0.265 0.1908 0.1908 cu.m.
8 PROVIDING M15 GRADE
CONCRETE BED
FOR SEPTIC TANK 1 4.1 1.3 0.075 0.39975

a FOR SOAKPIT
A=2.26 1 2.26 0.075 0.1695

b DEDUCTION FOR COVER


A=0.15 -1 0.15 0.075 -0.01125
0.459 cu.m.
9
PROVIDING AND FIXING IN
POSITION TOR STEEL FE500
1% OF QUANTITY OF RCC
WORK
=1% X 0.459 1 0.35 0.35
0.35 quintals
10 20MM THICK INTERNAL
PLASTER IN CM(1:6)
a LONG WALL 2 3.7 1.6 11.84
b
SHORT WALL 2 0.9 1.6 2.88

BAFFLE WALL 2 0.9 1.35 2.43


17.15 sq.m.
11 PROVIDING 100mm
DIAMETER SEWER IFLUENT
PIPE
a WC TO SEPTIC TANK 1 3.3 3.3
b
SEPTIC TANK TO SOALPIT 1 4.25 4.25
7.55 m
12 45cm DIA. MANHOLE COVER 1 1
1 nos.
13 PROVIDING
100X100X60mm SEWER
COVER 2 2
2 nos.
14 PROVIDING BALLAST OF
OVERSIZE BURNED BRICK
KANKAR FOR FILLING
SOAKPIT FOR 0.1m DEPTH
A=1.767 1 1.767 2.4 4.2408
4.24 cu.m.
15 PROVIDING AND FIXING
G.I. VENTILATOR COWL ON
VENT PTPE 1 1
1nos.
16 PROVIDING AND FIXING
75mm DIA. VENT PIPE 1 3.1 3.1