Product datasheet
Specifications
CONZERV EM6436H VAF PF P&E
RS485 CL 1.0
METSEEM6436HCL10RS
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Main
Range EasyLogic
Product name EasyLogic EM64XXH RS
Device short name EM6436H
Product or component type Multi-function meter
Complementary
Device application Power monitoring
Energy monitoring
Type of measurement Current
Voltage
Frequency
Power factor
RPM
Active power
Active energy
Metering type Average current Iavg
Average voltage Vavg
Frequency
Unbalance voltage
Percentage of load
Phase currents
Voltage U21, U32, U13, V1, V2, V3
Active, reactive, apparent energy (signed, two quadrant)
Rotation speed
Power factor and displacement PF (signed, four quadrant)
Unbalance current
Apparent power S, S1, S2, S3
Calculated neutral current
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Counter functions Power interruption
ON hour counting
[Us] rated supply voltage 44...300 V AC 45...65 Hz
44...300 V DC
Network frequency 50 Hz
60 Hz
[In] rated current 5 A
1 A
Type of network 2P + N
3P + N
2P
1P + N
3P
Maximum power consumption in 4 VA at 240 V between phase and neutral
VA
1 Apr, 2023 1
Maximum power consumption in 2 W at 240 V
W
Display type 8 segments LED
Display colour Red
Messages display capacity 3 fields of 4 characters
Display digits 12 digit(s) - 14.2 mm in height
Communication of data All counters
Percentage of load
Last cleared log
Revolution speed
Reading of measurements
Tamperproof of settings Protected by access code
Sampling rate 32 samples/cycle
Measurement current 5…6000 mA
Signal Voltage (impedance 5 MOhm)4 x
Current 0.005...10 A (impedance 0.3 MOhm)6 x
Measurement voltage 46…277 V AC 50...60 Hz between phase and neutral
80…480 V AC 50...60 Hz between phases
277…999000 V AC 50...60 Hz with external VT
Frequency measurement range 45…65 Hz
Measurement accuracy Current +/- 0.5 %
Voltage +/- 0.5 %
Frequency +/- 0.05 %
Power factor +/- 0.01
Reactive power +/- 2 %
Active power +/- 1 %
Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 2 %
Apparent energy +/- 1 %
Accuracy class Class 1 active energy conforming to IEC 62053-21
Class 2 reactive energy conforming to IEC 62053-24
Demand intervals 1s
Local signalling Green LED: activity
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Communication port protocol Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2-wire, insulation 2500 V
Communication port support Screw connector: RS485
Data recording Energy consumption logs
Material Polycarbonate
Flame retardance V-0 conforming to UL 94
Mounting mode Flush-mounted
Mounting support Framework
Fixing mode By clamp
Provided equipment Installation guide
Installation category III
Type of installation Indoor installation
Measurement category Category III 35…480 V
Electrical insulation class Class II
Connections - terminals Current circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s)
Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Tightening torque Current circuit: 0.9…1 N.m Philips No 2 screwdriver
Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver
Control circuit: 0.9…1 N.m Philips No 2 screwdriver
Communication: 0.5…0.6 N.m Philips no 1 screwdriver
2
1 Apr, 2023
Wire stripping length Current circuit: 3.68 mm
Voltage circuit: 7 mm
Control circuit: 7 mm
7 mm
Standards IEC 61010-1:ed. 3
UL 61010-1:ed. 3
Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
C-Tick
Width 96 mm
Depth 13 mm outside:
49 mm panel:
Height 96 mm
Net weight 300 g
Environment
Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Emission tests conforming to FCC part 15 subpart C
Emission tests conforming to FCC part 15 subpart E
Overvoltage category III
IP degree of protection IP51 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity 5…95 % at 50 °C
Pollution degree 2
Ambient air temperature for -10…60 °C
operation
Ambient air temperature for -20…70 °C
storage
Operating altitude <= 2000 m
Service life 7 year(s)
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.88 cm
Package 1 Width 9.6 cm
Package 1 Length 9.6 cm
Package 1 Weight 0.265 kg
Unit Type of Package 2 S03
Number of Units in Package 2 18
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 4.77 kg
1 Apr, 2023 3
Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
EU RoHS Directive Compliant
EU RoHS Declaration
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
Recommended replacement(s)
4
1 Apr, 2023