A2 Merged
A2 Merged
B B B
5214 5214 5214
1798 1300 900 900
1 1 1
1160
CABINET
1441
3835
3835
BEDROOM 1
638
SHELVE
696
7410
7410
7410
2 A
A 2 A
A 2 A
A
DINING AREA
2400
3575
3575
ROOF DECK
BEDROOM 2
1771
3 3 3
500
B A L C O N Y
A B 3 2 1
APEX APEX
2700
2700
3RD FFL 3RD FFL
3000
3000
9000
9000
2ND FFL 2ND FFL
3000
3000
GFFL GFFL
300
300
NGL NGL
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TE CT, WETHER THE UNLAWFUL FOR A NY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTL Y OR I N WHOL E, WI THO UT THE WRI TTE N
PTR NO: PLACE ISSUED: OWNER
CO N S E N T O F A CH I T E CT O R A UT HO R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
B A 1 2 3
APEX APEX
2700
2700
3000 3RD FFL 3RD FFL
3000
9000
9000
2ND FFL 2ND FFL
A B
B
B
5214
1
3000
3000
G U T T E R
GFFL GFFL
300
300
NGL NGL
3835
1 REAR ELEVATION 2 LEFT ELEVATION
A-03 SCALE 1 :100 M A-03 SCALE 1 :100 M
7410
2 A
A
A B 1 2 3
3575
APEX APEX
SEE ROOF DETAIL
SEE ROOF DETAIL
2700
2700
3
ROOF DECK
ROOF DECK
3RD FFL 3RD FFL
5 ROOF PLAN
A-03 SCALE 1 :100 M
3000
3000
9000
T&B BEDROOM 2
9000
BEDROOM 2
BEDROOM 1
BALCONY
2ND FFL 2ND FFL
3000
3000
GFFL GFFL
300
300
NGL NGL
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TE CT, WETHER THE UNLAWFUL FOR A NY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTL Y OR I N WHOL E, WI THO UT THE WRI TTE N
PTR NO: PLACE ISSUED: OWNER
CO N S E N T O F A CH I T E CT O R A UT HO R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
5214 5214 5214
1798 1300 900
3239
3835
3835
7410
7410
7410
2400
3575
3575
1771
GROUND FLOOR REFLECTED SECOND FLOOR REFLECTED THIRD FLOOR REFLECTED
1 CEILING PLAN 2 CEILING PLAN 3 CEILING PLAN
A-04 SCALE 1 :100 M A-04 SCALE 1 :100 M A-04 SCALE 1 :100 M
CEILING FINISHES
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
5214 5214 5214
1798 1300 900
1160
1441
3835
3835
638
WALL FINISHES
696
7410
7410
7410
2400
CONCRETE PAINTED SEMI GLOSS LATEX
3575
3575
60X30 PORCELAIN TILES
1771
WOOD WIND WALL PANEL
1 GROUND FLOOR WALL FINISH 2 SECOND FLOOR WALL FINISH 3 THIRD FLOOR WALL FINISH
A-05 SCALE 1 :100 M A-05 SCALE 1 :100 M A-05 SCALE 1 :100 M
973
1441
3835
3835
FLOOR FINISHES
638
696
7410
7410
7410
3575
3575
1771
4 GROUND FLOOR PATTERN LAYOUT 5 SECOND FLOOR PATTERN LAYOUT 6 THIRD FLOOR PATTERN LAYOUT
A-05 SCALE 1 :100 M A-05 SCALE 1 :100 M A-05 SCALE 1 :100 M
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
FFL FFL FFL FFL FFL
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
CEILING LINE CEILING LINE
300mmx600mm
300mmx600mm
CERAMIC TILES
CERAMIC TILES
1
4 2
3
NICHE
SUNKEN 1 "
ELEVATION 1 ELEVATION 2
PLAN
ELEVATION 3 ELEVATION 4
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S . IAPOA :
GENERAL NOTES
ALL ELECTRICAL WORKS HEREIN SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF THE
SCHEDULE OF LOADS AND COMPUTATIONS
PHILIPPINE ELECTRICAL CODE, THE LAWS ORDINANCES OF THE LOCAL CODE ENFORCING AUTHORITIES AND THE
REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANY.
POWER PANEL
1. ALL WIRING METHOD FOR LIGHTING, POWER, TELEPHONE, CCTV, CATV, INTERCOM, PAGING AND TRAFFIC SYSTEM PANEL: POWER PANEL (PP) MAIN: 2-30.0 mm². CU. THHN
SHALL BE DONE IN PVC PIPE FOR ALL EMBEDDED IN DRYWALL PARTITION AND DROPPED CEILING AND IMC PIPE FOR
FIRE ALARM SYSTEM, EXPOSED CONDUIT LAYOUT, FEEDER DISTRIBUTION AND MAJOR POWER CONDUIT RISER. LOCATION: DINING AREA CONDUIT: 32 mm. Ø PVC
2. SMALLEST BRANCH CIRCUIT WIRE SHALL BE 3.5mm² THHN FOR POWER AND LIGHTING SYSTEM IN RACEWAY 15 mmØ
TRADE SIZE CONDUIT. WIRE SHALL BE INSULATED FOR 600 VOLTS.
3. ALL BRANCH CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED IN THE PLAN. EXPOSED CIRCUIT RUN SHALL BE MOUNTING: FLUSHED NOTE: ALL LIGHTING FIXTURES TO BE USED ARE LED LIGHTS
INSTALLED PARALLEL TO OR PERPENDICULAR WITH THE BUILDING LINE AND SUPPORTED BY CONDUIT CLAMPS
EVERY 1.5 METERS, DIAGONAL CONDUIT RUN SHALL NOT BE ACCEPTED. CKT. CIRCUIT
4. WHENEVER NECESSARY PULLBOX OF PROPER SIZE AND DIMENSION SHALL BE PROVIDED ALTHOUGH NOT
CIRCUIT DESCRIPTION QTY WATTS VOLTS AMP WIRES CONDUITS
NO. BREAKER
INDICATED IN THE PLAN. ALL BOXES SHALL BE PROVIDED WITH METAL PLATE COVER.
5. ALL LIGHT CONTROLLED SWITCHES SHALL BE RATED 15 AMPS. 220 AC ONLY. SWITCHES SHALL BE INSTALLED FOR 3 - LIGHTING OUTLET
OPERATION WITH HORIZONTAL MOTION.
1 16 - PINLIGHT 20 672 230 2.43 15AT 2 - 2.0mm SQ THHN 15mm Ø PVC
6. ALL PANEL BOARD SHALL BE PROVIDED WITH GROUNDING TERMINALS, GROUNDING SYSTEM SHALL BE
CONNECTED TO A GROUND ROD. 1 - CEILING FAN
7. ALL BRANCH CIRCUIT HOMERUN FOR POWER AND LIGHTING SHALL NOT BE COMBINED IN THE SAME RACEWAY. 4 - LIGHTING OUTLET
8. FOR EACH SPARE CIRCUIT BREAKER IN PANELBOARD PROVIDE 15 mmØ RACEWAY TERMINATING IN 100 mm DEEP 2 24 728 230 2.92 15AT 2 - 2.0mm SQ THHN 15mm Ø PVC
TYPE SQUARE BOX WITH COVER BELOW CEILING SLAB AND SHALL BE PROVIDED WITH PULL WIRES. 20- PINLIGHT
9. ALL METALLIC CONDUIT, CABINET, BOXES AND EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED.
10. ALL MATERIALS TO BE USED SHALL BE NEW AND APPROVED FOR THE LOCATION AND PURPOSES. 2 - LIGHTING OUTLET 15mm Ø PVC
11. ALL MOLDED CASE CIRCUIT BREAKERS FOR MOTORS SHALL BE INDUSTRIAL TYPE. 3 7 - PINLIGHT 10 140 230 1.22 15 AT 2 - 2.0mm SQ THHN
12. BOXES SHALL BE MADE OF CODE GAUGE STEEL WITH ZINC CHROMATE PROTECTION. 1 - CEILING FAN
13. ALL RECEPTACLE OUTLET SHALL BE PROPERLY GROUNDED TO THE BOX BY MEANS OF GROUNDING LUGS.
14. MOUNTING HEIGHT NOT SHOWN ON SCHEDULE ARE AS FOLLOWS: 4 CONVENIENCE OUTLETS 5 1800 230 7.83 20 AT 2 - 3.5mm SQ THHN 20mm Ø PVC
a. LIGHT CONTROLLED SWITCHES ------------
1.40 METER ABOVE FLOOR FINISH @ CENTER 5 CONVENIENCE OUTLETS 9 3240 230 14.09 20AT 2 - 3.5mm SQ THHN 20mm Ø PVC
b. DUPLEX CONVENIENCE OUTLET ------------
0.20 METER ABOVE FLOOR FINIS @ CENTER
UNLESS OTHERWISE INDICATED BY THE FIELD CONVENIENCE OUTLETS 4 1440 230 6.26 20 AT 2 - 3.5mm SQ THHN 20mm Ø PVC
6
CONDITION
c. TELEPHONE OUTLET ------------ 0.20 METER ABOVE FLOOR FINIS @ CENTER 7 1.5 AIRCONDITIONING UNITS 1 1500 230 6.52 30AT 2 - 5.5mm SQ THHN 20mm Ø PVC
UNLESS OTHERWISE INDICATED BY THE FIELD
CONDITION 8 1.5 AIRCONDITIONING UNITS 1 1500 230 6.52 30AT 2 - 5.5mm SQ THHN 20mm Ø PVC
d. INTERCOM OUTLET ------------ 1.40 METER ABOVE FLOOR FINIS @ CENTER
UNLESS OTHERWISE INDICATED BY THE FIELD
CONDITION
9 1.5 AIRCONDITIONING UNITS 1 1500 230 6.52 30AT 2 - 5.5mm SQ THHN 20mm Ø PVC
e. PANELBOARD / DISCONNECT ------------ 1.40 METER ABOVE FLOOR FINIS @ CENTER
UNLESS OTHERWISE INDICATED BY THE FIELD 10 SPARE -
CONDITION
15. ALL WIRES AND CABLES SHALL BE COLOR CODED AS FOLLOWS: DEMAND FACTOR: 80%
TOTAL - 12,492 - 54.31
PHASE A ----------------------------------------------------- RED
I = 43.45 AMP USE 2-30.0 mm². THHN WITH 32 mm. Ø RSC
PHASE B ----------------------------------------------------- YELLOW
PHASE C ----------------------------------------------------- BLUE
GROUND ----------------------------------------------------- GREEN
16. ALL CONDUIT, BOXES AND SUPPORT SHALL BE COLOR CODED.
MAIN FEEDER
a. POWER & LIGHTING SYSTEM ------------------ GRAY 2 - 14mm2 + 8.0mm2 EGC
b. AUXILLARY SYSTEM ------------------ ORANGE
c.FIRE ALARM SYSTEM ------------------ RED
17. CONDUIT SLEEVES AND FLOOR SLOT PENETRATION THROUGH ELECTRICAL AND TELEPHONE ROOM WALLS / POWER SOURCE SERVICE
CLOSET SPACES SHALL BE PROPERLY SEALED-OFF WITH FIRE RETARDANT MATERIALS TO MAINTAIN FIRE 230 V. ENTRANCE
RESISTIVE RATINGS OF THE FLOOR OPENING. 60Hz M KILOWATT - HOUR
18. THE ELECTRICAL CONTRACTOR SHOULD REFER TO THE ARCHITECTURAL AND INTERIOR DESIGN PLAN FOR THE METER
EXACT LOCATION AND MOUNTING HEIGHT OF ALL VISIBLE WIRING DEVICES, FIXTURES AND THE LIKES. WEATHER PROOF
19. THE ELECTRICAL CONTRACTOR SHALL PROVIDE SHOP DRAWING IN ANY CHANGES IN MOUNTING HEIGHT OR
WIRES
LOCATION FOR THE APPROVAL OF THE ARCHITECT OR ENGINEER.
20. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE SUPERVISION OF A DULY
QUALIFIED LICENSED ELECTRICAL ENGNEER. 60A MAIN BREAKER BUILDING
WALL
ALL MOUNTING HEIGHTS ARE SUBJECT TO THE APPROVAL OF THE ARCHITECT / OWNER.
LIGHTING 1 2 LIGHTING PP:
15A 15A
60AT
LIGHTING 3 4 POWER GROUND
15A 20A MAIN: ELECTRIC METER
FLOOR
POWER 5 6 POWER 150AT
20A 20A PANEL NEMA BOX
A.C.U 7 8 A.C.U BOARD
30A 30A
A.C.U 9 10 SPARE
30A
16mm Ø GROUNDING
ROD NOT LESS THAN
2.44m LONG
GROUNDING 2-30.0mm² Ø
THHN WIRE
2
8.0mm THHN Wire (G) IN 65mm Ø RSC
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
t SABC
u
e t
e f
A A
f f u u
v
A A
g h t B
i t u Stuv Sqr
f f Ss
Sp r r
s A A C
LEGEND & SYMBOL
p 3
Sklm Sno PPB
Sghi e f e FIRE EXTINGUISHER
Sef Sp
q
2GANG CONVENIENCE OUTLET
o
d p
L.E.D PIN LIGHT(ROUND FLAT)
n n
LIGHT BULB (RECESSED)
k k PENDANT LIGHT (SINGLE)
l
PPB
m
b c c b Sj
Sbcd
1 COVE LIGHT (STRIP LED)
PPB
Sa 2
PPB
PENDANT LIGHT
a a j j
Sa 1GANG LIGHTING SWITCH
Sab 2GANG LIGHTING SWITCH
Sabc 3GANG LIGHTING SWITCH
1 GROUND FLOOR LIGHTING LAYOUT 2 SECOND FLOOR LIGHTING LAYOUT 3 THIRD FLOOR LIGHTING LAYOUT
PANEL BOARD
E-02 SCALE 1 :100 M E-02 SCALE 1 :100 M E-02 SCALE 1 :100 M
JUNCTION BOX
WP WEATHER PROOF OUTLET
C.O. C.O.
1 HOMERUN- LIGHITNG CKT .NO.
PPB
WP
C.O.
C.O.
C.O.
C.O. WP
C.O.
4 6
PPB PPB
A.C.U.
9 5
PPB
PPB PPB
C.O.
4 GROUND FLOOR POWER LAYOUT 5 SECOND FLOOR POWER LAYOUT 6 THIRD FLOOR POWER LAYOUT
E-02 SCALE 1 :100 M E-02 SCALE 1 :100 M E-02 SCALE 1 :100 M
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
GENERAL NOTES LEGEND DESCRIPTION LEGEND DESCRIPTION
1. GRADE OF HORIZONTAL PIPINGS
GATE VALVE
WATER METER
WF WALL MOUNT FAUCET M METER
RUN ALL HORIZONTAL PIPINGS IN RESPECT ALIGNMENT W/A UNIFORM GRADE OF NOT
UNION PATENTE
LESS THAN (2%) TWO PERCENT.
GATE VALVE
TAP FROM DS DOWNSPOUT CO CLEAN OUT
2. CHANGE IN DIRECTIONS TO FIXTURES
WATER MAIN
ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF FOURTY FIVE
GATE VALVE PLAN HB HOSE BIBB FD FLOOR DRAIN
DEGREES (45°) WYE LONG SWEEP QUARTER BEND SIX EIGHT OR SIXTEENTH BENDS WHEN THE
GATE VALVE
CHANGE OF FLOW IS HORIZONTAL OR TO VERTICAL. A SINGLE WYE 81 BEND COMBINATION MAYBE
USED ON WASTE LINES TEES AND CROSSES MAYBE USED ON VENT PIPES. CB CATCH BASIN SANITARY LINE
UNION PATENTE
3. PROHIBITED FITTINGS
WATER METER
TO FIXTURE TAP FROM LAV LAVATORY WATER DISTRIBUTION LINE
NO DOUBLE OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL SOIL OR WASTE ELEVATION WATER MAIN
LINES. THE DRILLING AND TAPPING OF HOUSE DRAINS. WASTE OR VENT PIPES AND USE SADDLE HUB
AND BENDS ARE PROHIBITED. WC WATER CLOSET STORM DRAIN LINE
4. SLEEVES
CV CHECK VALVE GV GATE VALVE
PROVIDE PIPE SLEEVES AT WALLS, COLUMNS OR SLAB ONE SIZE BIGGER THAN THE WATER METER DETAIL
ACTUAL SIZE PASSING THROUGH WALL OR UNDER SLAB TO PROTECT PIPE FROM BREAKAGE.
AD AREA DRAIN SHO SHOWER
5. CLEAN OUT PIPE
MATERIAL SPECIFICATIONS:
INLET
OUTLET
OUTLET
FFL 100 MM Ø PVC PIPE OUTLET
LAV
LAV
W.C. FD
W.C.
PVC PIPE
100mm Ø
CV
GV
SECOND FLOOR WATER DC SECOND FLOOR
2 DISTRIBUTION LAYOUT SEPTIC
VAULT 5 SANITARY LAYOUT
TAP TO
P-02 SCALE 1 :100 M LC P-02 SCALE 1 :100 M
NEAREST WATERLINE
CONNECTION
LC
GROUND FLOOR
50mmØ PVC
HB
3
4"Ø
PPR
PIPE
RISER
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
LAV
FD
W.C.
FD SHO
3 4"ØR
PP IPE ER
P IS
R
DS DS DS DS
100mm Ø PVC FD FD
STORM DRAIN PIPE
CB CB
STORM DRAIN PIPE
100mm Ø PVC
V
LA
C.
W.
GROUND FLOOR STORM SECOND FLOOR STORM SH
O
DS
FD
DS G U T T E R
3 4"Ø R
PP IPE ER
P IS
R
CV
M
GV
E
LIN
O TER N
P T A IO
TAST WECT
E N
AR ON
NE C
FD FD
DS DS
WATER DISTRIBUTION
5 ISOMETRIC LAYOUT
P-03 SCALE 1 :100 M
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
R
E
T
T
U
G
DS
C
PV E
Ø IP
mm P
50 ENT
V
DS
FD
FD
DS
FD
DS
CO V
C LA
PV E C. FD
W.
Ø IP
mm T P FD
50 EN
V O
SH
C
PV IPE
mØ P
0m CK
10 STA
DS
V
LAD
C.
W.
F
O
SH FD
FD
DS
FD
C
PV IPE
mØ P
0m CK
10 STA
PE
PI Ø
C m
PV00m
1
DC TIC
P LT
SEVAU DS
LC
LC CB
TO GE E
PE A C P
PV PI
PI AIN Ø IN
E NTG DR m RA
U 0mM D
FL IN
EFXIST 0
1 OR
E ST
DS
CB
PE
PI
N C
AI PV
DR Ø
STORM DRAIN M m
OR 0m
ST 10
T
ES GE
AR NA
1 SANITARY ISOMETRIC LAYOUT NE AI
O T DR
2 ISOMETRIC LAYOUT T
P E
TATRE
S
P-04 SCALE 1 :100 M
P-04 SCALE 1 :100 M
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TECT, WE THER THE UNLA WFUL FOR ANY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTLY O R I N WHOLE , WI THO UT THE WRI TTEN
PTR NO: PLACE ISSUED: OWNER
CO N S E NT O F A CH I T E CT O R A U TH O R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
.
0
50 P.
TY
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TE CT, WETHER THE UNLAWFUL FOR A NY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTL Y OR I N WHOL E, WI THO UT THE WRI TTE N
PTR NO: PLACE ISSUED: OWNER
CO N S E N T O F A CH I T E CT O R A UT HO R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
DESIGN OF FOOTING
REBARS
Dimension Thickness
DESIGNATION (m) (m) REMARKS (RE: FOOTING SCHEDULE)
AsW AsL COLUMN/PEDESTAL
SCHEDULE OF COLUMN
DEPTH
SOIL
(RE: FOOTING SCHEDULE)
FY= 275MPA /GRADE40, FC'= 3000PSI
DIMENSION / REINFORCEMENT
DESIGNATION FOUNDATION - SECOND FLOOR LEVEL THIRD FLOOR LEVEL Spacing of ties REINFORCEMENT
FOOTING
(10mm diameter bar) ( RE: PLAN & SCHED)
DEPTH
Dimension (mm) Reinforcement Dimension (mm) Reinforcement (fy= grade 33)
CLR
TYP
COLUMN
C1 300X300 250X250 2 @ 50mm, 2 @ 100mm, 4 @ 120mm,
( RE: PLAN & SCHED)
rest 160mm O.C.
8-20mm Ø 6-16mm Ø
SCHEDULE OF BEAM
DESIGNATION
BEAM SIZE NO. OF REINFORCEMENTS SPACING OF STIRRUPS PLAN SECTION
(10mm DIAMETER BAR)
Dimension (mm) @ SUPPORT @ MIDSPAN (FY=230 / GRADE 33)
1 TYPICAL FOOTING DETAIL
4-16mm Ø 2-16mm Ø S-02 SCALE NTS
B1 200X300 1@50, 3@75, 6@100, REST @ 180mm
O.C.
2-16mm Ø 4-16mm Ø
2-16mm Ø 2-16mm Ø
RB1 200X300 1@50, 3@75, 6@100, REST @ 180mm
O.C.
2-16mm Ø 2-16mm Ø
S2 (2-WAY) 100 12mm @ 150mm 12mm @ 300mm 12mm @ 300mm 12mm @ 150mm 12mm @ 300mm 12mm @ 300mm 2 CANTILEVER DETAIL
SCHEDULE OF STAIR S-02 SCALE NTS
FY=230MPA (MICRO ALLOY, FC'=3,000 PSI
LANDING
16mm DIA REBARS @100mm C.C 12mm DIA REBARS @200mm C.C EXTRA TOP BARS
150
12mmØ BAR (VERIFY)
16mm DIA REBARS @100mm C.C 12mm DIA REBARS @200mm C.C REBARS ALONG
SECOND FLIGHT 150
LONG SPAN
12mmØ @200mm (SEE SPACING)
O.C. TEMP. BARS
CONTINUOUS TOP BARS
16mmØ @150mm @L/4
N.G.L.
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TE CT, WETHER THE UNLAWFUL FOR A NY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTL Y OR I N WHOL E, WI THO UT THE WRI TTE N
PTR NO: PLACE ISSUED: OWNER
CO N S E N T O F A CH I T E CT O R A UT HO R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .
A B A B A B A B
5214 5214 5214 5214
FTB B1 B1 RB1
1 1 1 1
C1-F1 GUTTER
C1-F1
RB1
FTB
B1
B1
3835
3835
3835
3835
B1
B1
RB1
FTB
S2 S2
FT
FT
FT
FTB B1 B1
7410
7410
7410
7410
2 2 2 2 RB1
C1-F1 C1-F1
B1
C-PURLINS SPACED
B1
B1
B1
FTB
FTB
3575
3575
3575
3575
@600mm O.C .
S2 S2
FTB B1 B1
3 3 3 3
C1-F1 C1-F1
S1
100mm THK.
SLAB ON FILL WITH
10mm Ø TEMP. BARS
SPACED AT 500mm O.C.
1 FOUNDATION PLAN 2 SECOND FLOOR FRAMING PLAN 3 THIRD FLOOR FRAMING PLAN 4 ROOF FRAMING PLAN
S-03 SCALE 1:100MM S-03 SCALE 1:100MM S-03 SCALE 1:100MM S-03 SCALE 1:100MM
BEAM/WALL BEAM/WALL
PROJECT TITLE: R.A. 9266 SECTION 33 DATE REVISIONS SIGN SHEET CONTENTS: APPROVED BY: SHEET NO:
IMPORTANT: DRAWINGS AND SPECIFICATIONS AND
OTHER CONTRACT DOCUMENTS DULY SIGNED AND
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE AS SHOWN
PROPOSED: INTELLECTUAL PROPERTY AND DOCUMENTS OF THE
ARCHI TE CT, WETHER THE UNLAWFUL FOR A NY
PERSON TO DUPLICATE OR MAKE COPIES OF SAID
THREE-STOREY RESIDENTIAL DOCUMENTS FOR USE IN THE REPITITION OF AND PRC NO: OR NO:
OTHER PROJECTS OR BUILDINGS, WETHER EXECUTED
PA RTL Y OR I N WHOL E, WI THO UT THE WRI TTE N
PTR NO: PLACE ISSUED: OWNER
CO N S E N T O F A CH I T E CT O R A UT HO R O F S A I D TIN NO: DATE ISSUED:
LOCATION: D O C U M E N T S .