Abstract: Recently Permanent Magnet Synchronous Generator are mostly used in the Wind Energy Conversion System
applications This work is clearly deal with the study of Wind Energy Conversion System WECS by way of Permanent Magnet
Synchronous Generator PMSG with Z Source Inverters. The PMSGs and wind turbines are gradually entered in the field of
power generation huge wind farms are used at constant voltage and frequency to increase capacity power supply Particularly
Permanent Magnet Synchronous Generators is used in this machinery due to special characteristics such as low weight volume
and high. PMSG never required the power supply at the starting time of power production PMSGs run at synchronous speed.
These type of inverter are classified has Z-Source Inverter ZSI, Quasi Z Source Inverter QZSI, Trans Z Source Trans ZSI and
Cascaded Multi Cell Z Source Inverter CMCTZSI etc. This inverter is operated such as shoot through state and on shoot
through state previously to convert DC supply to AC supply where the DC supply side have been boosted up to required AC
supply level are executed. The above mention shoot through state is not applicable to implementing in the conventional Voltage
Source Inverter VSI and Current Source Inverter CSI. The PMSG and types of Z Source inverter systems are simulated in
MATLAB Simulation platform.
I. INTRODUCTION
With the abundant available of renewable energy system, like solar, Wind Energy Conversion System is to reduce the
environmental impact and to maintain the sustained power during power demand. The conventional plant uses fossil fuels such as
coal and petroleum products to run the steam turbines and produce the thermal power generation. The fossil fuel utilization has a
bad effect on the atmosphere and it is essential to reduce the polluting as well as exhausting fuel. The penetration of renewable
energy system particularly wind energy has been increased rapidly during the past few years and it is expected to develop more in
the future Electric power system is planned to generate and distribute electrical energy to the consumers with the defined
parameters. At normal operating condition the frequency varies as an outcome of the variation of the real power generated and
consumed, will leads to voltage drop in the transmission lines and distribution lines. Regulating the voltage at the desired level in
the distribution system is really a task in power system operation. Maintaining a sinusoidal wave shape of voltage or current
waveform is very difficult owing to the nonlinearities in several devices utilized for electric energy generation, transmission,
distribution and the end users. Real power and reactive power variations will affect the entire power system operation. This
unregulated power is fed to customer load side, to face severe power quality problems. As a result, the power system required
keeping the quantities near to the nominal value. Active power control, frequency regulation and reactive power compensation are
the highly complex issue in the wind turbine. The active power is regulated linearly with frequency difference between certain range
(47 Hz -52 Hz) with a dead band (49.85 Hz - 50.15 Hz) and the regulating wind turbine speed is 10 % of the rated power per
second. The wind turbine generally, operates in normal conditions (90%-105% voltage and 49-51 Hz frequency). However, it is
capable to operate beyond the range within certain specified time limits. The real power generation of a wind turbine could not be
synchronized; because the input power is limited by the wind speed. Still, an amount of rotating reserve may be kept if the wind
power turbine is operated at a lower power level, than the available power level. Because of this reason, revenues will go down. The
huge scale energy storage system may be in present, some fast response energy storage devices. It could be well technically suited
for this purpose, though more work is needed to solve the solution as an economical one. From the wind power system operator the
warm reserve allocation amount is generation units may be extra expenditure.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1708
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
This paper described the biggest inexhaustible limit extension program on the planet is taken up by India. The public authority is
meaning to build a portion of clean energy through a huge push in renewable. Centre drivers for advancement and sending of new
and sustainable power in India have been Energy security, Electricity deficiencies, Energy Access, Climate change, etc. The
government is assuming a functioning part in advancing the selection of sustainable power assets by offering different motivations,
for example, age-based impetuses (GBIs), capital and interest endowments, reasonability hole subsidizing, concessional account,
financial motivators, and so forth [2].
This article explained, the change in converter utilization to accomplish power stream control as two info sources share using a
single inductor. The change proportion of the converter is higher than other TPCs. Along these lines, the level of the opportunity of
obligation cycle is enormous. The converter can have a higher voltage gain for both low-voltage ports with a lower turn proportion
and a sensible obligation proportion. The voltage stress of switches is low; accordingly, conduction misfortune can be additionally
improved by receiving low Rds (on) switches [3].In this article, the converters used in the hybrid system are intriguing for
hybridizing elective fuel sources and providing the yield load. The hybrid structure uses just four force switches that are
autonomously controlled with four distinctive obligation proportions. Using these obligation proportions, following the greatest
intensity of the PV source, setting the FC power, and managing the yield voltage. To plan the converter control framework, a little
sign model is acquired in every activity mode. Because of the cooperation of converter control circles, a decoupling network is
utilized to configure separate shut circle regulators [4].
This article discussed the converters behaviour of broad variation in voltages of owing to sources to a steady yield voltage. A helper
circuit is utilized for accomplishing the turn-on ZVS of all switches. At different circumstances, the operational conditions of the
converter can be separated into two states, including a solitary force flexibly and a double force gracefully state. In the double force
gracefully express, the information circuits associated in arrangement along with the planned heartbeat width tweak can
significantly lessen the conduction loss of the switches [5]. This article described converter types, methodology and its operating
modes. converter parts among Cuk and SEPIC converters and it works in both individual and synchronous modes, in light of the
accessibility of source and kills the need of information channel to smother the high recurrence sounds. Subsequently, it has the
upside of basic structure and decreased converter parts. The converter is planned for the crossbreed wind and PV framework. The
converter dependent on the accessibility of the environmentally friendly power sources [6].This paper delineated all the MPPT units
that are at present utilized in crossover frameworks incorporate a few unmistakable MPPT regulators, so that, each MPPT regulator
is committed to a subsystem. Utilizing an unmistakable MPPT calculation and regulator for every subsystem of a half breed
framework unequivocally confounds the framework usage, builds cost, and diminishes the precision of the MPPT cycle. MPP
tracker for crossbreed energy unit/photovoltaic/wind power age frameworks, the tracker is classified "general tracker" since it
utilizes a brought together calculation and regulator to simultaneously follow the MPPs of the photovoltaic (PV), energy component
(FC), and wind energy change (WEC) subsystems of a mixture FC/PV/wind power framework [7].
This article described about the diverse MPPT strategies appropriate to power module (FC) frameworks, however, they are not
utilized in a half breed framework including an FC subsystem on the grounds that a different MPPT unit should be committed to the
FC subsystem that fundamentally confuses the framework execution, and expands cost [8]. This article proposed a technic in
which, it illuminates the together merging of the MPPT controllers for half and half FC/wind frameworks. The curiosity of the
strategy is that it utilizes a bound together calculation to simultaneously follow the maximum power tracking’s (MPPs) of the FC
and wind energy change (WEC) subsystems joined to one another to shape a crossover FC/wind framework. Also, the procedure is
sensor less, and tracks the MPP of the WEC subsystem, not the MPP of its wind turbine, so it extricates the most noteworthy
electrical force from the WEC subsystem [9].
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1709
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
A Permanent Magnet Synchronous Generator is a generator, the excitation field is provided everywhere by a permanent magnet as
instead of a coil. The word synchronous refers to the fact that the rotor and magnetic field rotates in a similar speed, for the reason
that magnetic field is generated through shaft mounted permanent magnet mechanism and current is developed fixed armature. The
PMSG consists of a rotor and a three-phase stator like an Induction Generator. The stator and rotor have the equivalent number of
poles. The stator has coils wound around them, which are accommodated within slots. The stator windings are displaced
circumferentially at the same intervals.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1710
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
B. Z-Source Inverter
The conventional Voltage Source Inverter (VSI) and Current Source Inverter (CSI) is either a buck operation otherwise a rated
voltage operation converter. In addition, not a boost converter and dual mode of buck- boost converter. When it is available of
output voltage range is restricted into either better or else minor than the input voltages. Except the Z-Source Inverter (ZSI) as an
option of power conversion concept as it can have both the voltage buck and boost capability.
The Figure.2, demonstrates the major circuit of the proposed Z- Source Inverter. It makes use of limited impedance network coupled
between the power source and the converter. It is consists of a split-inductor L1 and L2 and capacitors C1 and C2 connected in the
X form. The X-arms couple in the inverter to a DC voltage source. The voltage source may possibly a battery output voltage, a
diode rectifier output voltage or a wind generator coupled with a diodes rectifier output voltage. This impedance network allows the
DC voltage, earlier than convert to Alternating Current (AC) to Direct Current (DC); Shoot through state can be put into service. Z-
Source Inverter is buck or boosts its output voltage, and as well provides it with only one of its kind descriptions that cannot be
realized in conventional power inverters. The Z-Source Inverter has two working modes as shown in the Figure 3(a).
Figure 3.(a) Non Shoot through state (b) Shoot Through state.
In this Non Shoot through switching states, the input diode turns ON and the DC input voltage sources as well as the inductors are
transferring energy to the load and charged the capacitors, as an outcome the DC-link voltage of the bridge is boosted. The Shoot
through switching state has shown as in the Figure 3. (b), the input diode Din is reverse biased; the input DC establishment is
isolated from the load, and the two capacitors discharged energy to the inductors and to the load. In stable state, the capacitor
voltage is, the DC -link voltage and the output AC peak phase voltage of the Z-Source Inverter are as specified equation (1)
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1711
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
= (1)
1−
= . (2)
1−2
= = . ( ) (3)
2 2
Every place Do = To/Ts is the Shoot through duty ratio, To is the Shoot through time for each switching period, Ts, B = 1/1 – 2Do
is the boost factor and M is the modulation key. From (3), the peak AC output phase voltage can be restricted, mutually by adjusting
of the modulation index or Shoot through time. It can be superior to the input DC voltage by controlling the Shoot through time.
Evaluated to primary model of Z-Source Inverter and Quasi Z-Source Inverter is extra output voltage gain, a smaller amount
switching stress and very less harmonics content nearby in the exacting power system network. Consequently, not including human
intervention increases the power quality; particular grid connected Wind Energy Conversion System. Conventional Z-Source
Inverter controlled technology and Quasi Z-Source Inverter controlled technology are perfectly altered. While compared Z-Source
Inverter and Quasi Z-Source Inverter, the Quasi Z- Source inverter, Z-Source network absolutely different. The Quasi Z-
Source Inverter has recorded the boost capability. The Figure.4 is the major formation of the Quasi Z-Source Inverter. It provides
work for a unique impedance network preset between the power source and the circuit for converter. Those include a split-inductor
L1 and L2 and capacitors C1 and C2 linked in parallel. The Quasi Z-Source network is associated from the inverter to a DC power
supply. The DC power supply will be a battery or diode rectifier output power. The Quasi Z-Source Inverter a capable to boost up
the input voltage introduces an unexpected Shoot through switching state. In this state, the Quasi Z-Source Inverter is an immediate
performer of the identical inverter phase leg. This type of switching state is prohibited for the conventional Voltage Source Inverter
and Current Source Inverter.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1712
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
The special characteristics of the proposed Trans-Z Source Inverters are as follows:
1) The fundamental X-shape arrangement is retained.
2) Only two transformers are used. By changing the turn ratio of the transformers higher boost voltage gain will be obtained.
3) Although producing a high boost factor, the proposed Trans-ZSI does not consume a few extra diodes, which reduces its range,
charge and loss compared to conservative Voltage Source Inverter and Current Source Inverters.
4) It can be extended to the Quasi Z-Source Inverter topologies to get better input current outline and produces a lower voltage
stress on capacitors.
Parallel to the ZSI topology based on the X-shaped configuration has discontinuous input current and it requires a decoupling
capacitor bank at the front end to remove current discontinuity and to protect the energy source. In addition to that, it cannot start up
the suppress the resonant current and the resulting voltage and current spike can destroy the devices. The startup resonant current
problem can be suppressed and discontinuous input current problem can be eliminated in the Trans-Z Source Inverter. This chapter,
discussion is on basic circuit diagrams, construction and operation of PMSG and the three types of Z-Source Inverter. The
discussion is on the shoot through mode and non-shoot through mode of operation with few different types of Z-Source Inverters.
IV. PMSG AND QUASI Z-SOURCE INVERTER FOR GRID CONNECTED SYSTEM
When wind turbine rotates PMSG generates in the AC power. The generated AC power is directly fed to the uncontrolled three
phase bridge diode rectifier. The major utility of rectifier is which converts AC power to DC power. Subsequently, after
performance of DC conversion, the DC power is given to the Quasi Z-Source Network. The QZSI, it can be boosting the input
voltage by introducing Shoot through switching state. The boosted DC power is fed to the inverter section; in this inverter is convert
DC power to AC power. Here the Quasi Z-Source Inverter is controlled by Fuzzy Logic based HCC technique. The basic purpose of
this Fuzzy Logic based HCC to control the Quasi Z-Source Inverter; additionally real and reactive power is constantly maintained.
The involvement of current measurement loop is measured by the actual three phase grid current (I RYB act). In that case the error
comparator, compare the reference three phases set current (I RYB ref) and actual three phase grid current (I RYB act). At this
stage, current measurement loop is produced by the three phase error current (I RYB error). Consequently, the three phase error
current fed to the Fuzzy Logic Controller based HCC.
Figure 6 Schematic diagram of Proposed Wind Energy Conversion system with grid tied
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1713
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
Fuzzy Logic based HCC depends upon the error current signal to produces the firing pulses. Based on these firing pulses the
inverter is which converts DC power supply to AC power supply. The AC power supply from the Quasi Z-Source Inverter is
directly fed to the grid network. At that moment, the grid network is supplied to respective single and three phase customer loads. In
between if any harmonics present in the distribution lines it will be filtered on second order low pass filter. On other hand parallel
level power generating station (Source-I) is connected to the grid network. The PMSG as well as Quasi Z-Source Inverter is
produced power and Source- I power has been merged to the grid effectively as shown in the Figure 6. Outstanding power is the
spinning reserve, whenever the power demand occurs in the grid, at that time it can be utilized. This chapter, discuss the Wind
Energy Conversion System based Simulink block diagrams with different control methodology used in PMSG and the few types of
Z-Source Inverters.
The diode rectifier output voltage is directly fed to the Quasi Z- Source Network. Before converting DC to AC, the Shoot through
state is carried out by Quasi Z-Source Inverter. As a result, the voltage is boosted up to 1000V DC. It is denoted as Vdc (Capacitor
Voltage). The capacitor voltage is given in the Figure 9.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1714
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
The Quasi Z-Source network output voltage (1000V DC) is directly fed to the inverter circuit. The inverter converts 1000V DC to
480V AC, at same time, the current is maintained as constant by using Hysteresis current controller. The inverter output voltage is
(480V AC) given to the second orderlow pass filter. The filter removes the harmonics content in the 480V AC power supply Even if
there is a change in the power factor; the inverter maintains the output currents. The power factor of the load and source is given in
the Figure 10. The choice of power factor inverter current is shown. Actually, the required loads are 121 KVA active powers and
118 KVAR reactive powers are given in the Figure 12. But the former generating station i.e. Source (I) produced only 120 KVA
active power and 12 KVAR negative reactive power. It is given in the Figure 13.
Figure 9 Capacitor Voltage Figure 10.Power Factor for Load and Source
Figure 11 Inverter Current Figure 12.Active and Reactive Power for Source
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1715
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
Figure.13 Active and Reactive Power for Load Figure.14 Current and Voltage for Load.
The remaining active and reactive power lagging is managed by PMSG and Quasi Z-Source network. At the same time, load current
is not maintained identical to the voltage. But in this proposed system, it is maintained equal as shown in the Figure.14 .
B. Power Quality Enhancement using Quasi Z-Source Inverter by Hysteresis Current Controller based Fuzzy Logic Control
1) Simulation Results and Discussion
The PMSG generates 580V AC as specified in the Figure 15. PMSG output is (580V AC) applied to the three phase diode rectifier.
The diode rectifier is converts 580V AC to 520V DC output voltage as showing in the Figure 16. The DC output voltage is (520V
DC) fed to the Quasi Z- Source network. Before converting DC to AC voltage, the Shoot through state is carry in the Quasi Z-
Source Inverter. Using shoot through state, the voltage is boosted up to 1090V DC. It is denoted as Vdc. In this case, DC voltage
(1090V) is directly fed in to the inverter circuit.
The inverter converts DC (1090V) to the required 480V AC power supplied and same time, current is maintained asconstant using
FLC supported HCC. The inverter output voltage is (480V AC) given to the second order low pass filter. The filter eliminates
the harmonics in the 480V AC supply. The inverter is maintaining the current if there is any alteration in the grid power supply.
Here, if any load demand is present, there the QZSIis capable to compensate in the load demand.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1716
International Journal for Research in Applied Science & Engineering Technology (IJRASET)
ISSN: 2321-9653; IC Value: 45.98; SJ Impact Factor: 7.538
Volume 11 Issue III Mar 2023- Available at www.ijraset.com
VI. CONCLUSION
This project is mainly focused on the power quality improvement of Wind Energy Conversion System (WECS) with Permanent
Magnet Synchronous Generator (PMSG) and Z-Source Inverters (ZSI). The PMSG-based WECS with Z-Source Inverter and
maximum constant boost control with Third harmonic injection method is proposed. The Z-Source Inverter is used for maximum
power point tracking control. In addition to that, maximum power is delivered to grid system. Further Permanent Magnet
Synchronous Generator and Quasi Z Source Inverter are implemented based on Wind Energy Conversion System. The Hysteresis
Current Controller method and Fuzzy Logic Controller (FLC) is controlled by PMSG and Quasi Z-Source Inverter. Additionally, the
proposed Hysteresis Current Control based Fuzzy Logic Controller (FLC) has more advantages, such as more flexibility, Quick
control and static performances. This project is mainly focused to improve the power quality by using WECS with Trans Z-Source
Inverter controlled by Fuzzy Logic Controller technology. The PMSG-based WECS using Trans Z-Source Inverter is stabilized the
AC bus voltage by proposed control technique. Particularly, no additional circuits are present. Compared to conventional methods,
in this proposed FLC has more advantages, such as flexibility, easy to manage and control. The simulation results are verified, the
proposed FLC based Trans-ZSI is reduced the harmonics level to 0.07% with reference. Compared to conventional methods it is
maintaining the pure sinusoidal bus voltage in the grid system.
REFERENCES
[1] P. Kakosimos , K. Pavlou, A. Kladas, S. Manias, A single-phase ninelevel inverter for renewable energy systems employing model predictive control, Energy
Conversion and Management 89 (2015) 427–437.
[2] N. Eghtedarpour, E. Farjah, Control strategy for distributed integration of photovoltaic and energy storage systems in dc micro-grids, Renewable energy 45
(2012) 96–110.
[3] K. Arulkumar, D. Vijayakumar, K. Palanisamy, Modeling and control strategy of three phase neutral point clamped multilevel pv inverter connected to the grid,
Journal of Building Engineering 3 (2015) 195– 202.
[4] A. Chouder, S. Silvestre, N. Sadaoui, L. Rahmani, Modeling and simulation of a grid connected pv system based on the evaluation of main pv module
parameters, Simulation Modelling Practice and Theory 20 (1) (2012) 46–58.
[5] S. Ozdemir, N. Altin, I. Sefa, Single stage three level grid interactive mppt inverter for pv systems, Energy Conversion and Management 80 (2014) 561–572.
[6] N. Altin, S. Ozdemir, Three-phase three-level grid interactive inverter with fuzzy logic based maximum power point tracking controller, Energy Conversion
and Management 69 (2013) 17–26.
[7] A. Oshaba, E. Ali, S. A. Elazim, Mppt control design of pv system supplied srm using bat search algorithm, Sustainable Energy, Grids and Networks 2 (2015)
51–60.
[8] T. Esram, P. L. Chapman, Comparison of photovoltaic array maximum power point tracking techniques, IEEE Transactions on energy conversion 22 (2) (2007)
439–449
[9] F. Liu, S. Duan, F. Liu, B. Liu, Y. Kang, A variable step size inc mppt method for pv systems, IEEE Transactions on industrial electronics 55 (7) (2008) 2622–
2628.
[10] Q. Mei, M. Shan, L. Liu, J. M. Guerrero, A novel improved variable step-size incremental-resistance mppt method for pv systems, IEEE transactions on
industrial electronics 58 (6) (2011) 2427–2434.
[11] S. K. M. Niapour, S. Danyali, M. Sharifian, M. Feyzi, Brushless dc motor drives supplied by pv power system based on z-source inverter and fl-ic mppt
controller, Energy Conversion and Management 52 (8) (2011) 3043–3059.
[12] M. Alata, M. Al-Nimr, Y. Qaroush, Developing a multipurpose sun tracking system using fuzzy control, Energy Conversion and Management 46 (7) (2005)
1229–1245.
[13] M. Ouada, M. Meridjet, M. Saoud, N. Talbi, Increase efficiency of photovoltaic pumping system based bldc motor using fuzzy logic mppt control, WSEAS
Transactions on Power Systems 8 (3) (2013) 104–113.
[14] F. Aashoor, F. Robinson, Maximum power point tracking of photovoltaic water pumping system using fuzzy logic controller, in: Power Engineering
Conference (UPEC), 2013 48th International Universities’, IEEE, 2013, pp. 1–5.
[15] L. Letting, J. Munda, Y. Hamam, Optimization of a fuzzy logic controller for pv grid inverter control using s-function based pso, Solar Energy 86 (6) (2012)
1689–1700.
[16] M. Ouada, M. S. Meridjet, N. Talbi, Optimization photovoltaic pumping system based bldc using fuzzy logic mppt control, in: Renewable and Sustainable
Energy Conference (IRSEC), 2013 International, IEEE, 2013, pp. 27–31.
[17] X. Feng, H. Gooi, S. Chen, Hybrid energy storage with multimode fuzzy power allocator for pv systems, IEEE Transactions on Sustainable Energy 5 (2) (2014)
389–397.
©IJRASET: All Rights are Reserved | SJ Impact Factor 7.538 | ISRA Journal Impact Factor 7.894 | 1717