Gsfe Catalogue PDF
Gsfe Catalogue PDF
com/gsfe
Gas Separation and Filtration Division EMEA
NEW
ANTARES PLUS-E
Control Panel
Navigate, share, download and print this document using the quick
links on the control panel.
Search Function
Use the quick search to navigate directly to specific content.
For example part number or product name.
2
www.parker.com/gsfe
3
ISO Compressed Air Quality Standards
ISO8573-1 lists the main contaminants as solid particulate, water and oil. The purity levels for each contaminant are shown separately
in tabular form, however for ease of use, here all three contaminants are combined into one easy to use table.
When specifying the purity of air required, the standard Class 0 does not mean oil-free compressed air
must always be referenced, followed by the purity class
A Class 0 compressor does not guarantee oil-free
selected for each contaminant (a different purity class can
be selected for each contaminant if required). compressed air
Class 0 does not solely refer to oil contamination
An example of how to write an air quality specification is
shown below: A Class 0 specification must be ‘cleaner’ than the Class 1
specification for the contaminant chosen
ISO8573-1:2010 Class 1:2:1
The contamination levels stated for a Class 0 specification
ISO8573-1:2010 refers to the standard document and its must also be within the measurement capabilities of the test
revision, the three digits refer to the purity classifications equipment and test methods shown in ISO8573 Pt 2 to Pt 9
selected for solid particulate, water and total oil. Selecting
an air purity class of 1:2:1 would specify the following air The Class 0 specification must clearly state which
quality when operating at the standard’s reference contaminant the Class 0 claim refers to
conditions: i.e. “Solid Particulate”, “Water” or “Total Oil (aerosol, liquid
& vapour)”
Class 1 Particulate
Class 0 requires the user or the equipment supplier to show a
In each cubic metre of compressed air, the particulate
count should not exceed 20,000 particles in the 0.1 - 0.5 contamination level as part of a written specification
micron size range, 400 particles in the 0.5 - 1 micron size Example of a correctly written Class 0 specification
range and 10 particles in the 1 - 5 micron size range. “When preceded by OIL-X Grade AO General Purpose &
Class 2 Water Grade AA High Efficiency Coalescing Filters, OIL-X OVR
A pressure dewpoint (PDP) of -40°C or better is required Grade Adsorption Filters provide a delivered air quality in
and no liquid water is allowed. accordance with ISO8573-1:2010 Class 0 (≤0.003 mg/m³) for
total oil (oil aerosol & oil vapour)”
Class 1 Oil
The agreed Class 0 specification must be written on all
In each cubic metre of compressed air, not more than
0.01mg of oil is allowed. This is a total level for liquid oil, documentation to be in accordance with the standard
oil aerosol and oil vapour. Stating Class 0 without an accompanying contaminant
specification is meaningless and not in accordance with the
standard
4
www.parker.com/gsfe
2. The air quality required at each point of use may differ dependent upon the application.
3. Using the quality classifications shown in ISO8573-1 will allow easy selection of purification equipment.
4. ISO8573-1:2010 is the latest edition of the standard, however some facilities may still be operating on older revisions.
5. Specifying air quality as ISO8573-1, ISO8573-1:1991 or ISO8573-1:2001 refers to the previous editions of the standard and may
result in a different quality of delivered compressed air.
6. Ensure any ISO8573-1 air purity classifications are written in full and include the revision year to allow for correct product
selection.
7. Remember - Oil-free compressor installations require the same filtration considerations as oil lubricated compressor
installations.
2 OIL-X Grade AO OIL-X Grade AO (M) Dryer sized for -40°C PDP OIL-X Grade AO + AA
3 OIL-X Grade AO OIL-X Grade AO (M) Dryer sized for -20°C PDP OIL-X Grade AO
4 OIL-X Grade AO OIL-X Grade AO (M) Dryer sized for +3°C PDP OIL-X Grade AO
5 OIL-X Grade AO OIL-X Grade AO (M) Dryer sized for +7°C PDP -
For further information relating to ISO Compressed Air Quality Standards please refer to our white paper ‘Introduction to
ISO Compressed Air Quality Standards’. Available at parker.com/gsfe
5
Compressed Air Filters and Dryers
Typical Applications
Direct contact / in-direct contact applications in food manufacturing / beverage bottling / pharmaceutical manufacturing / dairies / breweries / wineries /
distilleries (In accordance with BCAS Best Practice Guideline 102 Food & Beverage Grade Compressed Air).
6
www.parker.com/gsfe
GENERAL USE
ISO 8573-1:2010 Class 1:1:2
ISO 8573-1:2010 Class 2.1.2 -70°C (-100°F) PDP
ISO 8573-1:2010 Class 1:2:2
ISO 8573-1:2010 Class 2.2.2 -40°C (-40°F) PDP
ISO 8573-1:2010 Class 1:3:2
ISO 8573-1:2010 Class 2.3.2 -20°C (-4°F) PDP AA
(M)
WS AO AA HIGH QUALITY
OIL-FREE AIR
AO
(M) ISO 8573-1:2010 Class 1:1:0
ISO 8573-1:2010 Class 1:2:0
AO AA ISO 8573-1:2010 Class 1:3:0
(M) (M)
OVR
COMPRESSOR AIR PARKER
RECEIVER ADSORPTION OR
HYBRID DRYER HIGH FLOW
TETPOR II
AO
(M)
WS AO
GENERAL PURPOSE
AA OIL-FREE AIR
ISO 8573-1:2010 Class 1:5:0
AO AA
(M) (M)
OVR
COMPRESSOR AIR REFRIGERATION
RECEIVER DRYER
HIGH QUALITY
IMPORTANT NOTE: OIL-FREE AIR
THE PURIFICATION EQUIPMENT REQUIREMENTS ARE IDENTICAL ISO 8573-1:2010 Class 2:1:0
FOR BOTH OIL-FREE AND OIL LUBRICATED COMPRESSORS. THE AA
ISO 8573-1:2010 Class 2:2:0
REQUIREMENTS FOR BREATHABLE QUALITY AIR ARE NOT COVERED IN (M) ISO 8573-1:2010 Class 2:3:0
ISO8573 REFER TO BREATHING AIR STANDARDS FOR THE COUNTRY OF OFAS
INSTALLATION. Oil Free Air System
Purification equipment should be installed where the air is at the lowest possible
temperature (i.e. downstream of after-coolers and air receivers). Point-of-use
purification equipment should be installed as close as possible to the application.
In order to correctly size purification equipment, there are a number of primary operating parameters that must be obtained
from the user’s site. These are:
• The MAXIMUM compressed air flow rate into the filters / dryer
• The MINIMUM operating pressure into the filters / dryer
• The MAXIMUM operating temperature into the filters / dryer
• The MAXIMUM ambient air temperature where the equipment is to be installed
• The required dewpoint (dryers)
Individually, each of the primary operating parameters can influence product sizing however collectively they can have a
major impact on product sizing and performance.
With the primary operating parameters, basic product selections can be made, however additional information may also be
required to finalise product selection. Secondary parameters include:
8
www.parker.com/gsfe
100 120
99
98 WSPX010
97 WSPX015 & WSPX020
80
96 WSPX025 & WSPX030
WSPX035, WSPX040 & WSPX045
95 60
WSPX010 WSPX050 & WSPX055
94
WSPX015 & WSPX020 40
93
WSPX025 & WSPX030
92 20
WSPX035, WSPX040 & WSPX045
91
WSPX050 & WSPX055
90
25% 50% 75% 100% 0 25% 50% 75% 100%
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Saturated Differential Pressure
Pipe 100% Flow 75% Flow 50% Flow 25% Flow
Model L/S m³/min m³/hr cfm
Size
mbar psi mbar psi mbar psi mbar psi
WSPX010A G FX 1/4" 10 0.6 36 21 53 0.8 29 0.4 14 0.2 4 0.1
WSPX010B G FX "
3/8 10 0.6 36 21 51 0.7 27 0.4 12 0.2 2 0.0
WSPX010C G FX 1/2" 10 0.6 36 21 48 0.7 25 0.4 10 0.1 0 0.0
WSPX015B G FX "
3/8 40 2.4 144 85 64 0.9 25 0.4 12 0.2 6 0.1
WSPX015C G FX 1/2" 40 2.4 144 85 55 0.8 22 0.3 10 0.1 4 0.1
WSPX020D G FX 3/4" 40 2.4 144 85 42 0.6 22 0.3 7 0.1 2 0.0
WSPX025D G FX 3/4" 110 6.6 396 233 98 1.4 55 0.8 23 0.3 4 0.1
WSPX025E G FX 1" 110 6.6 396 233 95 1.4 52 0.8 20 0.3 1 0.0
WSPX030G G FX 11/2" 110 6.6 396 233 82 1.2 30 0.4 13 0.2 4 0.1
WSPX035G G FX 11/2" 350 21 1260 742 57 0.8 24 0.3 5 0.1 5 0.1
WSPX040H G FX 2" 350 21 1260 742 52 0.8 19 0.3 0 0.0 0 0.0
WSPX045I G FX 21/2" 350 21 1260 742 55 0.8 22 0.3 3 0.0 1 0.0
WSPX050I G FX 21/2" 800 48 2880 1695 116 1.7 57 0.8 16 0.2 5 0.1
WSPX055J G FX 3" 800 48 2880 1695 111 1.6 52 0.8 11 0.2 0 0.0
10 Correction Factor 4.00 2.63 2.00 1.59 1.33 1.14 1.00 0.94 0.89 0.85 0.82 0.79 0.76 0.73 0.71 0.68
www.parker.com/gsfe
W D
W D
010A WSPX010AGFX
010B WSPX010BGFX
010C WSPX010CGFX
015C WSPX015CGFX
020D WSPX020DGFX
025D WSPX025DGFX
025E WSPX025EGFX
030G WSPX030GGFX
035G WSPX035GGFX
040H WSPX040HGFX
045I WSPX045IGFX
050I WSPX050IGFX
055J WSPX055JGFX
11
Compressed Air Filters
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors shown below.
Correction Factor 4.00 2.63 2.00 1.59 1.33 1.14 1.00 0.94 0.89 0.85 0.82 0.79 0.76 0.73 0.71 0.68
12
www.parker.com/gsfe
SFH029 SFH029N
SFH030 SFH030N
SFH037 SFH037N
SFH038 SFH038N
SFH066 SFH066N
SFH067 SFH067N
SFH088 SFH088N
SFH089 SFH089N
SFH097 SFH097N
SFH142 SFH142N
SFH180 SFH180N
SFH209 SFH209N
13
Compressed Air Filters
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
AO PX010 - PX055 (Float Drain) 1.5 22 16 232 2 35 65 149
AO PX010 - PX055 (Manual Drain) 1 15 20 290 2 35 80 176
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Saturated Differential Pressure
Pipe Replacement 100% Flow 75% Flow 50% Flow 25% Flow
Model L/S m³/min m³/hr cfm No.
Size Element
mbar psi mbar psi mbar psi mbar psi
AOPX010A G FX 1/4" 10 0.6 36 21 P010AO 1 123 1.8 84 1.2 53 0.8 27 0.4
AOPX010B G FX 3/
8 " 10 0.6 36 21 P010AO 1 124 1.8 85 1.2 55 0.8 30 0.4
AOPX010C G FX 1/2" 10 0.6 36 21 P010AO 1 121 1.8 82 1.2 44 0.6 15 0.2
AOPX015B G FX 3/
8 " 20 1.2 72 42 P015AO 1 122 1.8 84 1.2 46 0.7 20 0.3
AOPX015C G FX 1/2" 20 1.2 72 42 P015AO 1 91 1.3 53 0.8 31 0.4 13 0.2
AOPX020C G FX 1/2" 30 1.8 108 64 P020AO 1 124 1.8 82 1.2 45 0.7 20 0.3
AOPX020D G FX 3/4" 30 1.8 108 64 P020AO 1 113 1.6 72 1.0 34 0.5 10 0.1
AOPX025D G FX 3/4" 60 3.6 216 127 P025AO 1 125 1.8 80 1.2 43 0.6 21 0.3
AOPX025E G FX 1" 60 3.6 216 127 P025AO 1 80 1.2 50 0.7 27 0.4 11 0.2
AOPX030E G FX 1" 110 6.6 396 233 P030AO 1 125 1.8 80 1.2 42 0.6 30 0.4
AOPX030G G FX 11/2" 110 6.6 396 233 P030AO 1 90 1.3 49 0.7 27 0.4 9 0.1
AOPX035G G FX 11/2" 160 9.6 576 339 P035AO 1 81 1.2 44 0.6 18 0.3 5 0.1
AOPX040H G FX 2" 220 13.2 792 466 P040AO 1 113 1.6 69 1.0 40 0.6 20 0.3
AOPX045H G FX 2" 330 19.8 1188 699 P045AO 1 123 1.8 81 1.2 44 0.6 21 0.3
AOPX045I G FX 21/2" 330 19.8 1188 699 P045AO 1 95 1.4 64 0.9 35 0.5 15 0.2
AOPX050I G FX 21/2" 430 25.9 1548 911 P050AO 1 116 1.7 75 1.1 42 0.6 17 0.2
AOPX055I G FX 21/2" 620 37.3 2232 1314 P055AO 1 123 1.8 81 1.2 45 0.7 24 0.3
AOPX055J G FX 3" 620 37.3 2232 1314 P055AO 1 112 1.6 55 0.8 32 0.5 17 0.2
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84 0.80 0.76 0.73 0.71 0.68 0.66 0.64 0.62 0.61 0.59
14
www.parker.com/gsfe
Technical Data
Min Operating Max Operating Min Operating Max Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
AA PX010 - PX055 (Float Drain) 1.5 22 16 232 2 35 65 149
AA PX010 - PX055 (Manual Drain) 1 15 20 290 2 35 80 176
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Saturated Differential Pressure
Pipe Replacement 100% Flow 75% Flow 50% Flow 25% Flow
Model L/S m³/min m³/hr cfm No.
Size Element
mbar psi mbar psi mbar psi mbar psi
AAPX010A G FX 1/4" 10 0.6 36 21 P010AA 1 117 1.7 83 1.2 50 0.7 25 0.4
AAPX010B G FX 3/
8 " 10 0.6 36 21 P010AA 1 121 1.8 85 1.2 52 0.8 27 0.4
AAPX010C G FX 1/2" 10 0.6 36 21 P010AA 1 111 1.6 75 1.1 41 0.6 20 0.3
AAPX015B G FX 3/
8" 20 1.2 72 42 P015AA 1 115 1.7 79 1.1 44 0.6 24 0.3
AAPX015C G FX 1/2" 20 1.2 72 42 P015AA 1 80 1.2 51 0.7 27 0.4 12 0.2
AAPX020C G FX 1/2" 30 1.8 108 64 P020AA 1 122 1.8 80 1.2 41 0.6 18 0.3
AAPX020D G FX 3/4" 30 1.8 108 64 P020AA 1 100 1.5 60 0.9 37 0.5 24 0.3
AAPX025D G FX 3/4" 60 3.6 216 127 P025AA 1 86 1.2 57 0.8 33 0.5 10 0.1
AAPX025E G FX 1" 60 3.6 216 127 P025AA 1 66 1.0 45 0.7 25 0.4 10 0.1
AAPX030E G FX 1" 110 6.6 396 233 P030AA 1 122 1.8 82 1.2 42 0.6 11 0.2
AAPX030G G FX 11/2" 110 6.6 396 233 P030AA 1 104 1.5 55 0.8 30 0.4 10 0.1
AAPX035G G FX 11/2" 160 9.6 576 339 P035AA 1 75 1.1 45 0.7 20 0.3 5 0.1
AAPX040H G FX 2" 220 13.2 792 466 P040AA 1 90 1.3 60 0.9 40 0.6 20 0.3
AAPX045H G FX 2" 330 19.8 1188 699 P045AA 1 108 1.6 71 1.0 35 0.5 12 0.2
AAPX045I G FX 21/2" 330 19.8 1188 699 P045AA 1 108 1.6 70 1.0 32 0.5 15 0.2
AAPX050I G FX 21/2" 430 25.9 1548 911 P050AA 1 90 1.3 66 1.0 43 0.6 18 0.3
AAPX055I G FX 21/2" 620 37.3 2232 1314 P055AA 1 119 1.7 78 1.1 44 0.6 21 0.3
AAPX055J G FX 3" 620 37.3 2232 1314 P055AA 1 104 1.5 52 0.8 25 0.4 17 0.2
Filtration Tested In Accordance With OIL-X Grade AO & AA Oil Carryover versus Flow
Filtration Grade AO AA
with float drain with float drain 1
Oil Carryover (mg/m³)
AO Dry Particulate Down to 1 micron Not Applicable 99.925% 12 months Not Applicable
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
AO PX010 - PX055 (Float Drain) 1.5 22 16 232 2 35 65 149
AO PX010 - PX055 (Manual Drain) 1 15 20 290 2 35 80 176
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Dry Differential Pressure
Pipe Replacement 100% Flow 75% Flow 50% Flow 25% Flow
Model L/S m³/min m³/hr cfm No.
Size Element
mbar psi mbar psi mbar psi mbar psi
AOPX010A G MX 1/4" 10 0.6 36 21 P010AO 1 61 0.9 40 0.6 20 0.3 9 0.1
AOPX010B G MX 3/
8 " 10 0.6 36 21 P010AO 1 63 0.9 43 0.6 22 0.3 11 0.2
AOPX010C G MX 1/2" 10 0.6 36 21 P010AO 1 58 0.8 35 0.5 20 0.3 11 0.2
AOPX015B G MX 3/
8" 20 1.2 72 42 P015AO 1 60 0.9 38 0.6 23 0.3 12 0.2
AOPX015C G MX 1/2" 20 1.2 72 42 P015AO 1 27 0.4 15 0.2 10 0.1 5 0.1
AOPX020C G MX 1/2" 30 1.8 108 64 P020AO 1 58 0.8 35 0.5 15 0.2 8 0.1
AOPX020D G MX 3/4" 30 1.8 108 64 P020AO 1 38 0.6 20 0.3 10 0.1 5 0.1
AOPX025D G MX 3/4" 60 3.6 216 127 P025AO 1 54 0.8 39 0.6 21 0.3 8 0.1
AOPX025E G MX 1" 60 3.6 216 127 P025AO 1 22 0.3 15 0.2 9 0.1 5 0.1
AOPX030E G MX 1" 110 6.6 396 233 P030AO 1 56 0.8 38 0.6 20 0.3 7 0.1
AOPX030G G MX 11/2" 110 6.6 396 233 P030AO 1 42 0.6 26 0.4 12 0.2 6 0.1
AOPX035G G MX 11/2" 160 9.6 576 339 P035AO 1 19 0.3 9 0.1 5 0.1 2 0.0
AOPX040H G MX 2" 220 13.2 792 466 P040AO 1 31 0.4 19 0.3 16 0.2 7 0.1
AOPX045H G MX 2" 330 19.8 1188 699 P045AO 1 51 0.7 36 0.5 18 0.3 8 0.1
AOPX045I G MX 21/2" 330 19.8 1188 699 P045AO 1 40 0.6 27 0.4 12 0.2 6 0.1
AOPX050I G MX 21/2" 430 25.9 1548 911 P050AO 1 36 0.5 23 0.3 16 0.2 7 0.1
AOPX055I G MX 21/2" 620 37.3 2232 1314 P055AO 1 38 0.6 25 0.4 17 0.2 10 0.1
AOPX055J G MX 3" 620 37.3 2232 1314 P055AO 1 51 0.7 32 0.5 17 0.2 8 0.1
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84 0.80 0.76 0.73 0.71 0.68 0.66 0.64 0.62 0.61 0.59
16
www.parker.com/gsfe
Technical Data
Min Operating Max Operating Min Operating Max Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
AA PX010 - PX055 (Float Drain) 1.5 22 16 232 2 35 65 149
AA PX010 - PX055 (Manual Drain) 1 15 20 290 2 35 80 176
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Dry Differential Pressure
Pipe Replacement
Model L/S m³/min m³/hr cfm No. 100% Flow 75% Flow 50% Flow 25% Flow
Size Element
mbar psi mbar psi mbar psi mbar psi
AAPX010A G MX 1/4" 10 0.6 36 21 P010AA 1 64 0.9 36 0.5 21 0.3 10 0.1
AAPX010B G MX 3/
8 " 10 0.6 36 21 P010AA 1 65 0.9 38 0.6 22 0.3 11 0.2
AAPX010C G MX 1/2" 10 0.6 36 21 P010AA 1 63 0.9 39 0.6 20 0.3 10 0.1
AAPX015B G MX 3/
8" 20 1.2 72 42 P015AA 1 66 1.0 41 0.6 21 0.3 12 0.2
AAPX015C G MX 1/2" 20 1.2 72 42 P015AA 1 22 0.3 51 0.7 27 0.4 11 0.2
AAPX020C G MX 1/2" 30 1.8 108 64 P020AA 1 64 0.9 41 0.6 18 0.3 8 0.1
AAPX020D G MX 3/4" 30 1.8 108 64 P020AA 1 42 0.6 22 0.3 10 0.1 5 0.1
AAPX025D G MX 3/4" 60 3.6 216 127 P025AA 1 27 0.4 19 0.3 10 0.1 4 0.1
AAPX025E G MX 1" 60 3.6 216 127 P025AA 1 29 0.4 19 0.3 10 0.1 5 0.1
AAPX030E G MX 1" 110 6.6 396 233 P030AA 1 62 0.9 49 0.7 25 0.4 8 0.1
AAPX030G G MX 11/2" 110 6.6 396 233 P030AA 1 45 0.7 27 0.4 13 0.2 5 0.1
AAPX035G G MX 11/2" 160 9.6 576 339 P035AA 1 22 0.3 10 0.1 5 0.1 2 0.0
AAPX040H G MX 2" 220 13.2 792 466 P040AA 1 36 0.5 24 0.3 15 0.2 8 0.1
AAPX045H G MX 2" 330 19.8 1188 699 P045AA 1 47 0.7 25 0.4 18 0.3 15 0.2
AAPX045I G MX 21/2" 330 19.8 1188 699 P045AA 1 47 0.7 30 0.4 17 0.2 8 0.1
AAPX050I G MX 21/2" 430 25.9 1548 911 P050AA 1 40 0.6 27 0.4 16 0.2 8 0.1
AAPX055I G MX 21/2" 620 37.3 2232 1314 P055AA 1 45 0.7 27 0.4 17 0.2 10 0.1
AAPX055J G MX 3" 620 37.3 2232 1314 P055AA 1 54 0.8 35 0.5 17 0.2 9 0.1
17
Compressed Air Filters
140 140
120 120
AOPX010 AAPX010
AOPX015 & AOPX020 AAPX015 & AAPX020
Differential Pressure [mbar]
40 40
20 20
OIL-X Grade AO Dry Particulate Filter OIL-X Grade AA Dry Particulate Filter
Initial Dry Differential Pressure (25% - 100% Rated Flow) Initial Dry Differential Pressure (25% - 100% Rated Flow)
70 70
60 60
AOPX010 AAPX010
AOPX015 & AOPX020 AAPX015 & AAPX020
Differential Pressure [mbar]
Differential Pressure [mbar]
50 50
AOPX025 & AOPX030 AAPX025 & AAPX030
AOPX035, AOPX040 & AOPX045 AAPX035, AAPX040 & AAPX045
40 40
AOPX050 & AOPX055 AAPX050 & AAPX055
30 30
20 20
10 10
18
www.parker.com/gsfe
W D
W D
19
Compressed Air Filters
Coalescing & 0.5 mg/m³ <70 mbar <125 mbar WS (for bulk
AO Down to 1 micron 99.925% 12 months
Dry Particulate 0.5 ppm(w) (1 psi) (1.8 psi) liquid)
When oil
Oil Vapour 0.003 mg/m³ <140 mbar
ACS N/A N/A N/A vapour is AO+AA
Reduction 0.003 ppm(w) (2 psi)
detected
Important Note:
Using the same filter housings as their coalescing and dry particulate counterparts in the OIL-X range, Grade ACS filter elements differ in that they utilise a
deep wrapped bed of carbon cloth to adsorb oil vapour.
It is important to note, in-line adsorption filter elements have a different life span compared to coalescing and dry particulate filters and require more
frequent element changes. Should a 12 month service period be required, Parker OIL-X Grade OVR oil vapour reduction filters are recommended.
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
065 - 095 (Electronic Drain) 1 15 16 232 2 35 60 140
AO/AA
065 - 095 (Manual Drain) 1 15 16 232 2 35 100 212
ACS 065 - 095 (Manual Drain) 1 15 16 232 2 35 50 122
Grade
065ND X DN80 620 37.2 2232 1312 200 Grade 1
3 digit
Grade 070OD X DN100 1240 74.4 4464 2625 200 Grade 2 code Letter
AO denotes denotes D = Din E = Electronic I = Indicator
Grade
075PD X DN150 1860 111.6 6696 3938 200 Grade 3 AA filter pipe Flange M = Manual X = None
ACS
housing size
Grade
080PD X DN150 2480 148.8 8928 5251 200 Grade 4 size
Grade 085QD X DN200 3720 223.2 13392 7877 200 Grade 6
Grade 090RD X DN250 6200 372 22320 13129 200 Grade 10 Example code
Grade 095SD X DN300 8680 520.8 31248 18380 200 Grade 14 AO 090 P D E X
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84 0.80 0.76 0.73 0.71 0.68 0.66
20
www.parker.com/gsfe
H
D
Approx
170mm
21
Compressed Air Filters
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
ACS PX010 - PX055 (Manual Drain) 1 15 20 290 2 35 50 122
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Initial Dry Differential Pressure
Pipe Replacement 100% Flow 75% Flow 50% Flow 25% Flow
Model L/S m³/min m³/hr cfm No.
Size Element
mbar psi mbar psi mbar psi mbar psi
ACSPX010A G MX 1/4" 10 0.6 36 21 P010ACS 1 61 0.9 35 0.5 15 0.2 9 0.1
ACSPX010B G MX 3/
8 " 10 0.6 36 21 P010ACS 1 53 0.8 32 0.5 19 0.3 8 0.1
ACSPX010C G MX 1/2" 10 0.6 36 21 P010ACS 1 55 0.8 31 0.4 18 0.3 7 0.1
ACSPX015B G MX 3/
8" 20 1.2 72 42 P015ACS 1 65 0.9 33 0.5 13 0.2 5 0.1
ACSPX015C G MX 1/2" 20 1.2 72 42 P015ACS 1 46 0.7 37 0.5 20 0.3 9 0.1
ACSPX020C G MX 1/2" 30 1.8 108 64 P020ACS 1 77 1.1 35 0.5 15 0.2 7 0.1
ACSPX020D G MX 3/4" 30 1.8 108 64 P020ACS 1 79 1.1 37 0.5 17 0.2 8 0.1
ACSPX025D G MX 3/4" 60 3.6 216 127 P025ACS 1 66 1.0 34 0.5 14 0.2 4 0.1
ACSPX025E G MX 1" 60 3.6 216 127 P025ACS 1 46 0.7 24 0.3 13 0.2 4 0.1
ACSPX030E G MX 1" 110 6.6 396 233 P030ACS 1 57 0.8 27 0.4 16 0.2 8 0.1
ACSPX030G G MX 11/2" 110 6.6 396 233 P030ACS 1 65 0.9 35 0.5 15 0.2 5 0.1
ACSPX035G G MX 11/2" 160 9.6 576 339 P035ACS 1 26 0.4 12 0.2 8 0.1 4 0.1
ACSPX040H G MX 2" 220 13.2 792 466 P040ACS 1 36 0.5 23 0.3 13 0.2 4 0.1
ACSPX045H G MX 2" 330 19.8 1188 699 P045ACS 1 49 0.7 34 0.5 17 0.2 6 0.1
ACSPX045I G MX 21/2" 330 19.8 1188 699 P045ACS 1 68 1.0 40 0.6 20 0.3 6 0.1
ACSPX050I G MX 21/2" 430 25.9 1548 911 P050ACS 1 50 0.7 30 0.4 15 0.2 5 0.1
ACSPX055I G MX 21/2" 620 37.3 2232 1314 P055ACS 1 61 0.9 36 0.5 16 0.2 12 0.2
ACSPX055J G MX 3" 620 37.3 2232 1314 P055ACS 1 50 0.7 35 0.5 17 0.2 5 0.1
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84 0.80 0.76 0.73 0.71 0.68 0.66 0.64 0.62 0.61 0.59
22
www.parker.com/gsfe
W D
W D
23
Compressed Air Filters
*At system operating temperature and when corrected to match systems conditions.
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
OVR P300H - P550I 1 15 16 232 2 35 50 122
Flow Rates Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
Differential Pressure (OVR Only)
Pipe Replacement 100% Flow 75% Flow 50% Flow 25% Flow
Model L/s m /min m /hr
3 3
cfm No.
Size Cartridge
mbar psi mbar psi mbar psi mbar psi
OVRP300H G XX 2 80 4.8 289 170 P300OVR 1 350 5.1 198 2.9 46 0.7 11 0.2
OVRP350H G XX 2 163 9.8 586 345 P350OVR 1 350 5.1 198 2.9 46 0.7 11 0.2
OVRP400I G XX 21/2” 326 19.6 1172 690 P400OVR 1 350 5.1 198 2.9 46 0.7 11 0.2
OVRP450I G XX 21/2” 488 29.4 1758 1035 P450OVR 1 350 5.1 198 2.9 46 0.7 11 0.2
OVRP500I G XX 21/2” 651 39.2 2345 1380 P500OVR 1 350 5.1 198 2.9 46 0.7 11 0.2
OVRP550I G XX 21/2” 814 48.9 2931 1725 P550OVR 1
2 x OVRP550I G XX 21/2” 1629 97.9 5862 3451 P550OVR 2
3 x OVRP550I G XX 21/2” 2443 146.8 8793 5176 P550OVR 3
4 x OVRP550I G XX 21/2” 3257 195.8 11724 6901 P550OVR 4
5 x OVRP550I G XX 21/2” 4071 244.7 14656 8626 P550OVR 5
Select G for BSPP Threads / Select N for NPT Threads
24
www.parker.com/gsfe
W D
H
H
Correction Factors Inlet Temperature (CFIT) Correction Factors Inlet Temperature (CFIT)
Oil lubricated compressors Oil free compressors
°C °F Correction Factor °C °F Correction Factor
25 77 1.00 25 77 1.00
30 86 1.00 30 86 1.00
35 95 1.00 35 95 1.00
40 104 1.25 40 104 1.02
45 113 1.55 45 113 1.04
50 122 1.90 50 122 1.05
Correction Factor 2.00 1.60 1.33 1.14 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00
Correction Factor - Dewpoint (CFID) Correction Factor Inlet Vapour Content (CFIV)
Inlet Vapour
Installation Correction Factor Concentration 0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 2.0 3.0 4.0 5.0
mg/m3
After Dryer 1.00
Correction Factor 1 2 4 6 8 10 12 14 16 18 20 40 60 80 100
Before Dryer 4.00
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
010 - 030 (Float Drain) 1 15 16 232 2 35 30 86
AC
010 - 030 (Manual Drain) 1 15 20 290 2 35 30 86
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84 0.80 0.76 0.73 0.71 0.68 0.66 0.64 0.62 0.61 0.59
When ordering a filter for pressures above 16 bar g (232 psi g), use a manual drain. Replace F with M in product code. e.g. AC015BGFX becomes AC015BGMX.
26
www.parker.com/gsfe
W D
27
Compressed Air Filters
When oil
Oil Vapour 0.003 mg/m³ <140 mbar
ACS N/A N/A N/A vapour is AO+AA
Reduction 0.003 ppm(w) (<1.5 psi)
detected
Important Note:
Using the same filter housings as their coalescing and dry particulate counterparts, Grade ACS filter elements differ in that they utilise a wrapped bed
of carbon cloth to adsorb oil vapour. It is important to note, in-line adsorption filter elements have a different life span compared to coalescing and dry
particulate filters and require more frequent element changes.
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
AO/AA 0003G 1 14.5 10 145 2 35 50 122
ACS 0003G 1 14.5 10 145 2 35 30 86
Flow Rates
Pipe
Model L/S m³/min m³/hr cfm Replacement Element No.
Size
Correction Factor 2.65 1.87 1.53 1.32 1.18 1.08 1.00 0.94 0.88 0.84
28
www.parker.com/gsfe
29
Modular Aluminium Compressed Air Dryers
K-MT 1 - 4 -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -25 -13 Class 2.3.2
ISO8573-1 Classifications when used with Parker OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
115V 1ph
230V 1ph
K-MT 1 - 4 4 58 16 232 5 41 50 122 50 122 50/60Hz BSPP 65-86
50/60Hz
or 24V DC
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP L/s m3/min m3/hr cfm
K-MT 1 1/4" 2 0.13 8 5
Inlet flow rate relating to 1 bar(a) and 20°C;
K-MT 2 1/4" 4 0.25 15 9 relating to the suction performance of the
K-MT 3 1/4" 7 0.42 25 15 compressor, compression at 7 bar(g) and
35°C dryer inlet temperature, at 25°C ambient
K-MT 4 1/4" 10 0.58 35 21 temperature, 60 % relative humidity.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
30
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
31
Modular Aluminium Compressed Air Dryers
KA-MT 1 - 4 -40 -40 Class 2.2.1 -70 -100 Class 2.1.1 -25 -13 Class 2.3.1
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
115V 1ph
230V 1ph
KA-MT 1 - 4 4 58 16 232 5 41 50 122 50 122 50/60Hz BSPP 65-86
50/60Hz
or 24V DC
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP L/s m3/min m3/hr cfm
KA-MT 1 1/4" 2 0.13 8 5
Inlet flow rate relating to 1 bar(a) and 20 °C;
KA-MT 2 1/4" 4 0.25 15 9 relating to the suction performance of the
KA-MT 3 1/4" 7 0.42 25 15 compressor, compression at 7 bar(g) and
35 °C dryer inlet temperature, at 25 °C ambient
KA-MT 4 1/4" 10 0.58 35 21 temperature, 60 % relative humidity.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
32
www.parker.com/gsfe
W
D
Included Filtration
Dryer Inlet Dryer Outlet
Model High Efficiency Dry
General Purpose Dry
High Efficiency Filter Particulate Filter
Particulate Filter
(Option)
KA-MT 1 AAPX010A AOPX010A AAPX010A
KA-MT 2 AAPX010A AOPX010A AAPX010A
KA-MT 3 AAPX010A AOPX010A AAPX010A
KA-MT 4 AAPX010A AOPX010A AAPX010A
33
Modular Aluminium Compressed Air Dryers
CDAS HL -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
100-240V
CDAS HL BSPP or
4 58 16 232 5 41 50 122 55 131 (+/-10%) 1ph 24V DC <75
050 - 085 NPT
50/60Hz
Flow Rates
Pipe Size Inlet Flow Rate
Model BSPP or
NPT L/s m3/min m3/hr cfm
CDAS HL 050 1/2" 15 0.92 55 32
CDAS HL 055 1/2" 19 1.17 70 41
CDAS HL 060 1/2" 25 1.50 90 53
CDAS HL 065 1/2" 31 1.84 110 65
CDAS HL 070 3/4" 42 2.51 150 88
CDAS HL 075 1" 51 3.09 185 109 Stated flows are for operation at 7 bar (g) (102 psi g) with
CDAS HL 080 1" 61 3.67 220 129 reference to 20°C, 1 bar (a), 0% relative water vapour
pressure. For flows at other pressures, apply the correction
CDAS HL 085 11/2" 83 5.01 300 177 factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a
flow rate equal to or above the MDC.
34
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
35
Modular Aluminium Compressed Air Dryers
OFAS HL -40 -40 Class 2.2.0 -70 -100 Class 2.1.0 -20 -4 Class 2.3.0
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Dryer Operating Operating Operating Operating Ambient Thread
Supply Supply Level
Models Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
100-240V
OFAS HL BSPP or
4 58 16 232 5 41 50 122 55 131 (+/-10%) 1ph 24V DC <75
050 ~ 085 NPT
50/60Hz
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP or NPT L/s m3/min m3/hr cfm
OFAS HL 050 1/2" 15 0.92 55 32
OFAS HL 055 1/2" 19 1.17 70 41
OFAS HL 060 1/2" 25 1.50 90 53
OFAS HL 065 1/2" 31 1.84 110 65
OFAS HL 070 3/4" 42 2.51 150 88
OFAS HL 075 1" 51 3.09 185 109 Stated flows are for operation at 7 bar (g) (102 psi g) with
OFAS HL 080 1" 61 3.67 220 129 reference to 20°C, 1 bar (a), 0% relative water vapour
pressure. For flows at other pressures, apply the correction
OFAS HL 085 11/2" 83 5.01 300 177 factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a
flow rate equal to or above the MDC.
36
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
37
Modular Aluminium Compressed Air Dryers
FBP HL -40 -40 Class 1.2.0 -70 -100 Class 2.1.0 -20 -4 Class 1.3.0
ISO8573-1 Classifications when used with OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
100-240V
BSPP
FBP HL 050 ~ 085 4 58 16 232 5 41 50 122 55 131 (+/-10%) 24V DC <75
or NPT
1ph 50/60Hz
Flow Rates
Pipe Size Inlet Flow Rate
Model BSPP or
NPT L/s m3/min m3/hr cfm
FBP HL 050 1/2" 15 0.92 55 32
FBP HL 055 1/2" 19 1.17 70 41
FBP HL 060 1/2" 25 1.50 90 53
FBP HL 065 1/2" 31 1.84 110 65
FBP HL 070 3/4" 42 2.51 150 88
FBP HL 075 1" 51 3.09 185 109 Stated flows are for operation at 7 bar (g) (102 psi g) with
reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
FBP HL 080 1" 61 3.67 220 129
For flows at other pressures, apply the correction factors shown
FBP HL 085 11/2" 83 5.01 300 177 below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a
flow rate equal to or above the MDC.
38
www.parker.com/gsfe
W
D
Included Filtration
Dryer Inlet Dryer Outlet
39
Modular Aluminium Compressed Air Dryers
Technical Data
Minimum Maximum Minimum Maximum Maximum
Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Electrical Supply Level
Pressure Pressure Temperature Temperature Temperature Type
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
Not Applicable - Fully BSPP or
CDAS HL ATEX 4 58 16 232 5 41 50 122 55 131 <75
Pneumatic Operation NPT
Flow Rates
Pipe Size Inlet Flow Rate
Model BSPP or
NPT L/s m3/min m3/hr cfm
CDAS HL 050 ATEX 1/2" 15 0.92 55 32
CDAS HL 055 ATEX 1/2" 19 1.17 70 41
CDAS HL 060 ATEX 1/2" 25 1.50 90 53
CDAS HL 065 ATEX 1/2" 31 1.84 110 65
CDAS HL 070 ATEX 3/4" 42 2.51 150 88
CDAS HL 075 ATEX 1" 51 3.09 185 109 Stated flows are for operation at 7 bar (g) (102 psi g) with
reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
CDAS HL 080 ATEX 1" 61 3.67 220 129
For flows at other pressures, apply the correction factors shown
CDAS HL 085 ATEX 11/2" 83 5.01 300 177 below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a
flow rate equal to or above the MDC.
40
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
41
Modular Aluminium Compressed Air Dryers
MXS DS -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
100-240V
MXS102CDS ~ BSPP
4 58 13 190 5 41 50 122 55 131 (+/-10%) 1ph N/A <75
MXS108DS or NPT
50/60Hz
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow
rate equal to or above the MDC.
W D
Recommended Filtration
Dryer Inlet Dryer Outlet
43
Modular Aluminium Compressed Air Dryers
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
MXP102CDS - Not Applicable - Fully
4 58 13 190 5 41 50 122 55 131 BSPP <75
MXP108DS Pneumatic Operation
Flow Rates
Inlet Flow Rate
Model Pipe Size
L/s m3/min m3/hr cfm
MXP102C 2" 113 6.81 408 240
MXP103C 2" 170 10.22 612 360
MXP103 2" 213 12.75 765 450
MXP104 2½" 283 17 1020 600
MXP105 2½" 354 21 1275 750
MXP106 2½" 425 26 1530 900 Stated flows are for operation at 7 bar (g) (102 psi g) with
MXP107 2½" 496 30 1785 1050 reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors shown
MXP108 2½" 567 34 2040 1200 below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow
rate equal to or above the MDC.
44
www.parker.com/gsfe
W D
Recommended Filtration
Dryer Inlet Dryer Outlet
45
Modular Aluminium Compressed Air Dryers
Multi-banking
A unique advantage of modular aluminium dryers is the ability to access the full cross sectional area of the drying columns and fill the
desiccant material with a snowstorm filler, a device which provides maximum packing density of the desiccant material. Snowstorm filling
the desiccant material provides a low and equal resistance to the air flow which allows multiple drying chambers to be used without
preferential flow and provides a consistent outlet dewpoint with less desiccant and in a smaller, more compact and lightweight dryer.
Another advantage of snowstorm filling is that it also allows multiple dryer banks to be used without preferential flow because each
individual dryer will have an equal pressure drop. This is a feature unique to modular dryers and is known as multi-banking.
47
Modular Aluminium Compressed Air Dryers
48
www.parker.com/gsfe
49
Modular Aluminium Compressed Air Dryers
50
www.parker.com/gsfe
51
Modular Aluminium Compressed Air Dryers
MXLE -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
400V 460V
MXLE 102C -
5 73 13 190 5 41 50 122 55 131 +/-10% +/-10% BSPP <75
MXLE 108
3PH 50Hz 3PH 60Hz
MXLE 102C 2" 113 6.81 408 240 MXLEP2C-E 3 MXLEP2C-E-60 4.8
MXLE 103C 2" 170 10.22 612 360 MXLEP3C-E 3 MXLEP3C-E-60 4.8
MXLE 103 2" 213 12.75 765 450 MXLEP3-OL 4 MXLEP3-OL-60 6.5
MXLE 104 2½" 283 17 1020 600 MXLEP4-OL 5.5 MXLEP4-OL-60 9
MXLE 105 2½" 354 21 1275 750 MXLEP5-OL 5.5 MXLEP5-OL-60 9
MXLE 106 2½" 425 26 1530 900 MXLEP6-OL 8 MXLEP6-OL-60 13
MXLE 107 2½" 496 30 1785 1050 MXLEP7-OL 9.5 MXLEP7-OL-60 15.5
MXLE 108 2½" 567 34 2040 1200 MXLEP8-OL 9.5 MXLEP8-OL-60 15.5
For Higher Flow Capacities - Contact Parker Dryer & vacuum pump to be ordered separately.
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow
rate equal to or above the MDC.
D
W
Included Filtration
Dryer Inlet Dryer Outlet
K-MT 10 - 95 -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -25 -13 Class 2.3.2
ISO8573-1 Classifications when used with Parker OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
115V 1ph
230V 1ph
K-MT 10 - 95 4 58 16 232 5 41 50 122 50 122 50/60Hz BSPP 65-86
50/60Hz
or 24V DC
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP L/s m3/min m3/h cfm
K-MT 10 1" 30 1,8 105 62
K-MT 15 1" 40 2,4 145 85
K-MT 20 1" 56 3,3 200 118
K-MT 25 1½" 70 4,3 255 150
K-MT 35 1½" 97 5,8 350 206
K-MT 45 1½" 117 7 420 247
Inlet flow rate relating to 1 bar(a) and 20 °C;
K-MT 60 2" 172 10,3 620 365 relating to the suction performance of the
K-MT 75 2" 208 12,5 750 441 compressor, compression at 7 bar(g) and
35 °C dryer inlet temperature, at 25 °C ambient
K-MT 95 2½" 261 15,7 940 553
temperature, 60 % relative humidity.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
W D
Included Filtration
Dryer Inlet Dryer Outlet
Model Oil Vapour High Efficiency Dry
High Efficiency General Purpose Dry
Reduction Filter Particulate Filter
Filter Particulate Filter
(Option) (Option)
K-MT 10 AAPX025E AOPX025E ACSPX025E AAPX025E
K-MT 15 AAPX025E AOPX025E ACSPX025E AAPX025E
K-MT 20 AAPX025E AOPX025E ACSPX025E AAPX025E
K-MT 25 AAPX030G AOPX030G ACSPX030G AAPX030G
K-MT 35 AAPX030G AOPX030G ACSPX030G AAPX030G
K-MT 45 AAPX035G AOPX035G ACSPX035G AAPX035G
K-MT 60 AAPX040H AOPX040H ACSPX040H AAPX040H
K-MT 75 AAPX040H AOPX040H ACSPX040H AAPX040H
K-MT 95 AAPX045I AOPX045I ACSPX045I AAPX045I
KA-MT 10 - 95 -40 -40 Class 2.2.1 -70 -100 Class 2.1.1 -25 -13 Class 2.3.1
ISO8573-1 Classifications when used with Parker OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
115V 1ph
230V 1ph
KA-MT 10 - 95 4 58 16 232 5 41 50 122 50 122 50/60Hz BSPP 65-86
50/60Hz
or 24V DC
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP L/s m3/min m3/h cfm
KA-MT 10 1" 30 1.8 105 62
KA-MT 15 1" 40 2.4 145 85
KA-MT 20 1" 56 3.3 200 118
KA-MT 25 1½" 70 4.3 255 150
KA-MT 35 1½" 97 5.8 350 206
KA-MT 45 1½" 117 7 420 247
Inlet flow rate relating to 1 bar(a) and 20 °C;
KA-MT 60 2" 172 10.3 620 365 relating to the suction performance of the
KA-MT 75 2" 208 12.5 750 441 compressor, compression at 7 bar(g) and
35 °C dryer inlet temperature, at 25 °C ambient
KA-MT 95 2½" 261 15.7 940 553
temperature, 60 % relative humidity.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
W D
Included Filtration
Dryer Inlet Dryer Outlet
Model High Efficiency Dry
General Purpose Dry
High Efficiency Filter Particulate Filter
Particulate Filter
(Option)
KA-MT 10 AAPX025E AOPX025E AAPX025E
KA-MT 15 AAPX025E AOPX025E AAPX025E
KA-MT 20 AAPX025E AOPX025E AAPX025E
KA-MT 25 AAPX030G AOPX030G AAPX030G Included in standard scope of supply:
KA-MT 35 AAPX030G AOPX030G AAPX030G Prefilter (AA) including float drain.
Afterfilter (AO) including manual drain.
KA-MT 45 AAPX035G AOPX035G AAPX035G
Optional: (Delivered separately):
KA-MT 60 AAPX040H AOPX040H AAPX040H Oil vapour reduction filter (ACS)
KA-MT 75 AAPX040H AOPX040H AAPX040H High efficiency dry particulate filter (AA)
KA-MT 95 AAPX045I AOPX045I AAPX045I including manual drain
KE-MT 120 - 600 -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with Parker OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
230V 1ph 115V / 1ph
KE-MT 120 - 600 4 58 10* 145 5 41 50 122 50 122 Flange < 120
50Hz/60Hz 50/60Hz
* Higher operating pressures on request
Flow Rates
Inlet Flow Rate
Model Pipe Size
L/s m3/min m3/hr cfm
KE-MT 120 DN 50 333 20 1200 706
KE-MT 150 DN 65 430 26 1550 912
KE-MT 200 DN 65 556 33 2000 1177
KE-MT 250 DN 80 695 42 2500 1472
KE-MT 300 DN 80 833 50 3000 1766
KE-MT 380 DN 100 1056 63 3800 2237 Stated flows are for operation at 7 bar (g) (102 psi g) with reference to
20°C, 1 bar (a), 0% relative water vapour pressure. For flows at other
KE-MT 500 DN 100 1347 81 4850 2855
pressures, apply the correction factors shown below.
KE-MT 600 DN 125 1695 102 6100 3590 Dryers for smaller flows are available on request.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow
rate equal to or above the MDC.
58
www.parker.com/gsfe
W D
Recommended Filtration
Dryer Inlet Dryer Outlet
Model General Purpose High Efficiency General Purpose Dry Oil Vapour Reduction High Efficiency Dry
Prefilter Filter Particulate Filter Filter Particulate Filter
mandatory* mandatory* mandatory* optional optional
KE-MT 120 AOPX050I AAPX050I AOPX050I ACSPX050I AAPX050I
KE-MT 150 AOPX050I AAPX050I AOPX050I ACSPX050I AAPX050I
KE-MT 200 AOPX055I AAPX055I AOPX055I ACSPX055I AAPX055I
KE-MT 250 AOPX060K AAPX060K AOPX060K ACSPX060K AAPX060K
KE-MT 300 AOPX060K AAPX060K AOPX060K ACSPX060K AAPX060K
KE-MT 380 AO070O AA070O AO070O ACS070O AA070O
KE-MT 500 AO075O AA075P AO075O ACS075O AA075O
KE-MT 600 AO075O AA075P AO075O ACS075O AA075O
* prefilters (AO and AA) and afterfilter (AO) are mandatory but not included in scope of supply and must be ordered separately.
The filtration is mandatory to maintain trouble-free dryer operation.
WVM -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Dryer Operating Operating Operating Operating Ambient
Supply Supply Connection Level
Models Pressure Pressure* Temperature Temperature Temperature
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
400V 3ph
WVM 4 58 11 145 5 41 40 104 40 104 50Hz
On request Flanged 80-85
Flow Rates
Inlet Flow Rate Average
Model Pipe Size
L/s m3/min m3/hr cfm Power kW
WVM 45 DN 50 125 7.5 450 265 3.6
WVM 60 DN 50 169 10.2 610 359 5.3
WVM 80 DN 50 222 13.4 800 471 6.8
WVM 125 DN 80 325 19.5 1170 689 9.5
WVM 155 DN 80 408 24.5 1470 865 12.8
WVM 210 DN 80 569 34.2 2050 1207 16.8
WVM 310 DN 100 847 50.9 3050 1795 25.4 Inlet flow rate relating to 1 bar(a) and 20 °C;
WVM 370 DN 100 1028 61.8 3700 2178 30.8 relating to the suction performance of the
compressor, compression at 7 bar(g) and
WVM 520 DN 150 1403 84.3 5050 2972 41.8
35 °C dryer inlet temperature, at 25 °C ambient
WVM 615 DN 150 1681 101.0 6050 3561 52.6 temperature, 60 % relative humidity.
WVM 750 DN 150 2028 121.9 7300 4297 59.5 Dryers for higher flows are available on request.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with
a flow rate equal to or above the MDC.
60
www.parker.com/gsfe
W D
Required Filtration
Dryer Inlet Dryer Outlet
Model Dryer Connection
High Efficiency Filter General Purpose Dry Particulate Filter
61
Compressed Air Dryers
ATT+ -40 -40 Class 2.2.2 -70 -100 Class 2.1.2 -20 -4 Class 2.3.2
ISO8573-1 Classifications when used with Parker OIL-X pre / post filtration
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
230V 1ph
ATT+ 060/090/140 2 29 12 174 5 41 65 149 50 122 N/A BSPP <75
50Hz
400V 3ph
ATT+ 260/340 4 58 12 174 5 41 65 149 50 122 N/A BSPP <75
50Hz
Flow Rates
Dryer Pipe Inlet Flow Rate Average
Models Size L/s m3/min m3/hr cfm Power kW
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a flow
rate equal to or above the MDC.
62
www.parker.com/gsfe
ATT+060/090 ATT+140/260/340
H H
W D W D
Visual
Fault Indication
Service Indicator
EST - Energy
Saving
Technology
Visual Operation
Status (Strip LED)
Power On
Indication
Dewpoint Display
Alarm History
0-10V / 4-20mA
Dewpoint
Re-transmission
Data Log/
Retrieve*
Modbus
Protocol**
IOT Ready
Hybrid
Dryer
ATT+ 7" • • • • • • • • • • • •
*USB **RTU RS485 TCP/IP RJ45
Included Filtration
Dryer Inlet Dryer Outlet
63
Compressed Air Dryers
Technical Data
Min Max Min Max Max
Electrical Electrical Noise
Dryer Operating Operating Operating Operating Ambient Thread
Supply Supply Level
Models Pressure Pressure Temperature Temperature Temperature Connections
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
SPS 004-062 16 232 230V 1ph
2 29 5 41 65 149 50 122 50Hz / N/A BSPP <75
SPS 080-100 14 203 60Hz
Flow Rates
Pipe Inlet Flow Rate 50 Hz 50Hz Inlet Flow Rate 60Hz 60Hz
Model
Size L/s m3/min m3/hr cfm kW L/s m3/min m3/hr cfm kW
SPS 004 ½" 7 0.4 24 14 0.13 8 0.47 28 16 0.16
SPS 007 ½" 12 0.7 42 25 0.14 13 0.78 47 28 0.17
SPS 009 ½" 15 0.9 54 32 0.15 17 1.00 60 35 0.19 Stated flows are for operation
SPS 014 ¾" 23 1.4 84 49 0.15 27 1.60 96 57 0.18 at 7 bar (g) (102 psi g) with
reference to 20°C, 1 bar (a), 0%
SPS 018 ¾" 30 1.8 108 64 0.16 34 2.07 124 73 0.20
relative water vapour pressure,
SPS 026 1" 43 2.6 156 92 0.29 49 2.93 176 104 0.36 25 °C cooling air temperature,
SPS 032 1" 53 3.2 192 113 0.30 61 3.63 218 128 0.37 35 °C air inlet temperature and
+3°C pressure dewpoint. All
SPS 040 1" 67 4.0 240 141 0.31 76 4.53 272 160 0.38
models supplied with low GWP
SPS 052 1½" 87 5.2 312 184 0.46 100 6.02 361 212 0.56 refrigerant R513A.
SPS 062 1½" 103 6.2 372 219 0.57 119 7.15 429 253 0.69
For flows at other conditions,
SPS 080 1½" 133 8.0 480 282 0.73 154 9.25 555 327 0.90
apply the correction factors
SPS 100 1½" 167 10.0 600 353 0.74 191 11.48 689 406 0.91 shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
D
W
SPS 004 520 20.5 300 11.8 400 15.7 24 53 AOPX010C AAPX010C
SPS 007 520 20.5 300 11.8 400 15.7 24 53 AOPX015C AAPX015C
SPS 009 520 20.5 300 11.8 400 15.7 25 55 AOPX015C AAPX015C
SPS 014 580 22.8 330 13.0 550 21.7 35 77 AOPX020D AAPX020D
SPS 018 580 25.6 330 13.0 550 21.7 36 79 AOPX020D AAPX020D
SPS 026 650 25.6 400 15.7 630 24.8 46 101 AOPX025E AAPX025E
SPS 032 650 25.6 400 15.7 630 24.8 46 101 AOPX025E AAPX025E
SPS 040 650 25.6 400 15.7 630 24.8 47 104 AOPX025E AAPX025E
SPS 052 650 25.6 400 15.7 630 24.8 53 117 AOPX030G AAPX030G
SPS 062 650 25.6 400 15.7 630 24.8 55 121 AOPX030G AAPX030G
SPS 080 840 33.1 450 17.7 780 30.7 80 176 AOPX035G AAPX035G
SPS 100 840 33.1 450 17.7 780 30.7 80 176 AOPX035G AAPX035G
65
Compressed Air Dryers
Technical Data
Min Max Min Max Max
Electrical Electrical Noise
Dryer Operating Operating Operating Operating Ambient Thread
Supply Supply Level
Models Pressure Pressure Temperature Temperature Temperature Connections
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
PSE 400V 3ph 50Hz / BSPP & DIN
2 29 14 203 5 41 65 149 50 122 N/A <75
120 - 1800 460V 3ph 60Hz Flange
Flow Rates
Inlet Flow Rate at 50Hz Absorbed Inlet Flow Rate at 60Hz Absorbed
Pipe Power Power
Model at 50Hz at 60Hz
Size L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
kW kW
PSE 120 2" 200 12 720 424 1.32 215 13 773 455 1.7
PSE 140 2" 233 14 840 494 1.32 252 15 907 534 1.7
PSE 180 2" 300 18 1080 636 1.51 323 19 1163 685 1.9
PSE 220 21/2" 367 22 1320 777 1.79 399 24 1435 845 2.2 Stated flows are for
operation at 7 bar (g)
PSE 260 21/2" 433 26 1560 918 2.05 474 28 1708 1005 2.5
(102 psi g) with refer-
PSE 300 21/2" 500 30 1800 1059 2.62 539 32 1941 1142 3.3 ence to 20°C, 1 bar (a),
PSE 350 21/2" 583 35 2100 1236 3.22 624 37 2247 1323 4.0 0% relative water vapour
pressure, 25 °C cooling
PSE 460 DN100 767 46 2760 1625 3.22 835 50 3005 1769 3.9
air temperature, 35 °C
PSE 520 DN100 867 52 3120 1836 4.55 941 56 3386 1993 5.6 air inlet temperature and
PSE 630 DN100 1050 63 3780 2225 4.55 1172 70 4219 2483 5.6 +3°C pressure dewpoint.
All models supplied with
PSE 750 DN150 1250 75 4500 2649 6.52 1381 83 4970 2925 8.0
low GWP refrigerant
PSE 900 DN150 1500 90 5400 3178 9.05 1655 99 5957 3506 11.0 R513A.
PSE 1200 DN150 2000 120 7200 4238 9.05 2210 133 7956 4683 11.0
PSE 1500 DN200 2500 150 9000 5297 11.17 2760 166 9935 5848 13.6 For flows at other condi-
tions, apply the correction
PSE 1800 DN200 3000 180 10800 6357 13.12 3281 197 11812 6952 16.4 factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table
above with a flow rate equal to or above the MDC.
D
W
PSE 120 1365 53.7 703 27.7 1150 45.3 205 452 AOPX040H AAPX040H
PSE 140 1365 53.7 703 27.7 1150 45.3 205 452 AOPX040H AAPX040H
PSE 180 1365 53.7 703 27.7 1150 45.3 210 463 AOPX045I AAPX045I
PSE 220 1410 55.5 703 27.7 1151 45.3 260 573 AOPX050I AAPX050I
PSE 260 1410 55.5 703 27.7 1151 45.3 262 578 AOPX055I AAPX055I
PSE 300 1410 55.5 703 27.7 1151 45.3 264 582 AOPX055I AAPX055I
PSE 350 1410 55.5 703 27.7 1151 45.3 270 595 AOPX055I AAPX055I
PSE 460 2055 80.9 973 38.3 1287 50.7 380 838 AO070O AO070O
PSE 520 2055 80.9 973 38.3 1287 50.7 380 838 AO070O AA070O
PSE 630 2055 80.9 973 38.3 1287 50.7 420 926 AO070O AA070O
PSE 750 2055 80.9 1205 47.4 1974 77.7 730 1609 AO075P AA075P
PSE 900 2055 80.9 1205 47.4 1974 77.7 770 1698 AO075P AA075P
PSE 1200 2055 80.9 1205 47.4 1974 77.7 850 1874 AO080P AA080P
PSE 1500 2040 80.3 1517 59.7 2529 99.6 1070 2359 AO085Q AA085Q
PSE 1800 2040 80.3 1517 59.7 2529 99.6 1210 2668 AO085Q AA085Q
67
Compressed Air Filters and Dryers (20 bar to 350 bar)
Important Note:
Using the same filter housings as their coalescing and dry particulate counterparts, Grade A filter elements differ in that they utilise a bed of activated
carbon to adsorb oil vapour. It is important to note, in-line adsorption filter elements have a different life span compared to coalescing and dry particulate
filters and require more frequent element changes.
Technical Data
Minimum Operating Maximum Operating Minimum Operating Maximum Operating
Filtration Pressure Pressure Temperature Temperature
Filter Models
Grade
bar g psi g bar g psi g ºC ºF ºC ºF
V/ZP/XP GH3/350 - GH13/350 50 725 350 5076 2 35 80 176
A GH3/350 - GH13/350 50 725 350 5076 2 35 50 122
GH3/350 Grade 1/2" 101 6.1 365 215 1050 Grade 1 XP GH3/350XP
GH5/350 Grade 1/2" 139 8.4 501 295 1070 Grade 1
GH7/350 Grade 1/2" 215 12.9 776 457 1140 Grade 1
GH9/350 Grade 1/2" 287 17.3 1035 609 2010 Grade 1
GH11/350 Grade 1" 514 30.9 1852 1090 2020 Grade 1
GH12/350 Grade 11/2" 782 46.9 2816 1657 2030 Grade 1
GH13/350 Grade 11/2" 1184 71.0 4261 2508 2050 Grade 1
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative
water vapour pressure. For flows at other pressures, apply the correction factors shown below.
Correction Factor 2.65 2.42 2.24 2.09 1.97 1.87 1.67 1.53 1.41 1.32 1.25 1.18 1.13 1.08 1.04 1.00
68
www.parker.com/gsfe
123 mm
(4.8")
69
Compressed Air Filters and Dryers (20 bar to 350 bar)
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Dryer Operating Operating Operating Operating Ambient Thread
Supply Supply Level
Models Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
230V 1ph 115V 1ph 95-
HDK-MT 15 - 70 100 1450 350 5076 5 41 55 131 50 122 BSPP
50/60Hz 50/60Hz 115
Flow Rates
Pipe Size Inlet Flow Rate
Model
BSPP L/s m3/min m3/hr cfm
HDK-MT 15/350 G½ 56 3.3 200 118
HDK-MT 20/350 G½ 83 5.0 300 177
HDK-MT 25/350 G½ 111 6.7 400 235
HDK-MT 30/350 G½ 139 8.4 500 294
HDK-MT 40/350 G¾ 217 13 780 459 Stated flows are for operation at 7 bar (g) (102 psi g) with
HDK-MT 50/350 G¾ 261 16 940 553 reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other pressures, apply the correction factors
HDK-MT 70/350 G¾ 328 20 1180 695 shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow rate table above with a
flow rate equal to or above the MDC.
70
www.parker.com/gsfe
W
D
71
Breathable Quality Compressed Air
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Noise
Operating Operating Operating Operating Ambient Thread
Model Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
Fully
BAC-4015 4 58 8.5 123 5 41 30 86 55 131 BSPP <75
Pneumatic
Flow Rates
Pipe Size Inlet Flow Rate Regeneration Air Requirement
Model
Inlet Outlet L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
BAC-4015 G½ G¼ 11 0.68 41 24 2.36 0.14 8.5 5
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other conditions, apply the correction factors shown below.
To select a breathing air purifier, first calculate the MPC (Minimum Purification Capacity) using the formula below then select a breathing air
purifier from the flow rate table above with a flow rate equal to or above the MPC.
72
www.parker.com/gsfe
D W
Included Filtration
Dryer Inlet Dryer Outlet
Model General Purpose Oil Vapour Reduction General Purpose Dry High Efficiency Dry
High Efficiency Filter
Pre-filter Filter Particulate Filter Particulate Filter
BAC-4015 • • •
73
Breathable Quality Compressed Air
Technical Data
Minimum MaximumMinimum Maximum Maximum
Electrical Electrical Electrical Noise
Operating Operating
Operating Operating Ambient Thread Level
Models Pressure Pressure
Temperature Temperature Temperature Supply Supply Supply
Type
(Standard) (Option) (Option)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
230V / 1ph / 115V / 1ph /
BSP-MT 1-4 4 58 16 232 5 41 50 122 50 122 24V DC BSPP <75
50~60Hz 50~60Hz
Flow Rates
Flow Rate
Model Pipe Size
L/s m3/min m3/hr cfm
BSP-MT 1 G¼ 4 0.22 13 8
BSP-MT 2 G¼ 7 0.40 24 14
BSP-MT 3 G¼ 11 0.67 40 24
BSP-MT 4 G¼ 16 0.94 56 33
Stated flows are for operation at 13 bar (g) (189 psi g), 35°C (95°F) with reference to 20°C, 1 bar (a), 0%
relative water vapour pressure.
For flows at other conditions, apply the correction factors shown below.
To select a dryer, first calculate the MDC (Minimum Drying Capacity) using the formula below then select a dryer from the flow
rate table above with a flow rate equal to or above the MDC.
74
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
Models General Purpose High Efficiency General Purpose Dry
Pre-filter Filter Particulate Filter
BSP-MT 1-4 • • •
Filtration Grade AO AA AO
75
Breathable Quality Compressed Air
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Electrical Noise
Operating Operating Operating Operating Ambient Thread
Dryer Models Supply Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard) (Optional)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
85 - 265V
BSPP or
BAS HL 050 - 085 4 58 16 232 5 41 35 95 55 131 1ph 24V DC <75
NPT
50/60Hz
Flow Rates
Pipe Size Inlet Flow Rate
Model BSPP or
NPT L/s m3/min m3/hr cfm
BAS HL 050 1/2" 15 0.92 55 32
BAS HL 055 1/2" 19 1.17 70 41
BAS HL 060 1/2" 25 1.50 90 53
BAS HL 065 1/2" 31 1.84 110 65
BAS HL 070 3/4" 42 2.51 150 88
BAS HL 075 1" 51 3.09 185 109 Stated flows are for operation at 7 bar (g) (102 psi g) with
BAS HL 080 1" 61 3.67 220 129 reference to 20°C, 1 bar (a), 0% relative water vapour
pressure. For flows at other pressures, apply the correction
BAS HL 085 11/2" 83 5.01 300 177 factors shown below.
To select a dryer, first calculate the MTC (Minimum Treatment Capacity) using the formula below then select a dryer from the flow rate table above
with a flow rate equal to or above the MTC.
W D
Included Filtration
Dryer Inlet Dryer Outlet
Model Oil Vapour
General Purpose High Efficiency General Purpose Dry High Efficiency Dry
Reduction Filter &
Pre-filter Filter Particulate Filter Particulate Filter
Catalyst Stage
BAS HL 050 - BAS HL 085 • • • • •
Technical Data
Minimum Maximum Minimum Maximum Maximum
Electrical Noise
Operating Operating Operating Operating Ambient Thread
Models Supply Level
Pressure Pressure Temperature Temperature Temperature Type
(Standard)
bar g psi g bar g psi g °C °F °C °F °C °F dB(A)
85 - 265V BSPP or
BAM10 - BAM70 4 58 13 190 5 41 35 95 55 131 <75
1ph 50/60Hz NPT
Flow Rates
Inlet Flow Rate Regeneration Air Requirement
Model Pipe Size
L/s m /min
3
m /hr
3
cfm L/s m3/min m3/hr cfm
BAM10 G2 113 6.81 408 240 22.6 1.36 82 48
BAM20 G2 170 10.22 612 360 34.0 2.04 122 72
BAM30 G2 213 12.78 795 450 42.6 2.60 159 90
BAM40 G2 283 17 1020 600 56.6 3.40 204 120
BAM50 G2½ 354 21 1275 750 70.8 4.20 255 150
BAM70 G2½ 496 30 1785 1050 99.2 6.00 357 210
Stated flows are for operation at 7 bar (g) (102 psi g) with reference to 20°C, 1 bar (a), 0% relative water vapour pressure.
For flows at other conditions, apply the correction factors shown below.
To select a breathing air purifier, first calculate the MPC (Minimum Purification Capacity) using the formula below then select a breathing air purifier
from the flow rate table above with a flow rate equal to or above the MPC.
78
www.parker.com/gsfe
W D
Included Filtration
Dryer Inlet Dryer Outlet
Pipe Size
Models General Purpose High Efficiency Oil Vapour General Purpose Dry High Efficiency Dry
BSPP or NPT
Pre-filter Filter Reduction Filter Particulate Filter Particulate Filter
BAM10 - BAM70 G2 • • • • •
79
Condensate Management
Important Note:
Additives blended into the lubricants to prevent bacterial growth, rusting, corrosion, and to promote emulsification,
such as detergents etc., can have an impact on the separating process. Static oil/water separators are unable to separate stable
emulsions or oils that are miscible in water. Additionally, these units will not totally separate lubricants containing: Emulsifying
Agents; Glycol additives; or Polyglycol based coolants.
80
www.parker.com/gsfe
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 36.9 2.2 133 78 30.8 1.9 111 66 25.6 1.5 92 54
ES2150 58.6 3.5 211 124 50.0 3 180 106 40.6 2.4 146 86
ES2200 90.3 5.4 325 191 76.7 4.6 276 163 62.5 3.7 225 132
Rotary Screw,
ES2300 126.7 7.6 456 268 106.4 6.4 383 225 87.5 5.3 315 185
Vane
ES2400 253.4 15.2 912 537 212.8 12.8 766 451 175.0 10.5 630 371
ES2500 501.4 30.1 1805 1062 425.0 25.5 1530 900 346.4 20.8 1247 734
ES2600 997.6 59.9 3591 2114 849.2 51 3057 1800 689.5 41.4 2482 1461
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 27.8 1.7 100 59 23.3 1.4 84 49 19.2 1.2 69 41
ES2150 43.9 2.6 158 93 37.5 2.3 135 80 30.6 1.8 110 65
ES2200 67.8 4.1 244 144 57.8 3.5 208 122 46.9 2.8 169 99
Rotary Screw,
ES2300 95.3 5.7 343 202 80.0 4.8 288 169 65.8 3.9 237 139
Vane
ES2400 190.3 11.4 685 403 159.7 9.6 575 339 131.7 7.9 474 279
ES2500 377.0 22.6 1357 798 319.2 19.2 1149 677 260.6 15.6 938 552
ES2600 749.8 45 2699 1589 638.4 38.3 2298 1352 518.1 31.1 1865 1098
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 13.9 0.8 50 30 11.7 0.7 42 25 9.7 0.6 35 21
ES2150 22.2 1.3 80 47 18.9 1.1 68 40 15.6 0.9 56 33
ES2200 34.2 2.1 123 73 29.2 1.7 105 62 23.6 1.4 85 50
Rotary Screw,
ES2300 48.1 2.9 173 102 40.3 2.4 145 85 33.1 2 119 70
Vane
ES2400 96.1 5.8 346 204 80.6 4.8 290 171 66.4 4 239 141
ES2500 190.0 11.4 684 403 161.1 9.7 580 341 131.4 7.9 473 278
ES2600 378.4 22.7 1362 801 322.0 19.3 1159 682 261.4 15.7 941 554
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 11.4 0.7 41 24 9.4 0.6 34 20 7.8 0.5 28 17
ES2150 17.8 1.1 64 38 15.3 0.9 55 32 12.5 0.7 45 26
ES2200 27.5 1.7 99 59 23.6 1.4 85 50 19.2 1.1 69 40
Rotary Screw,
ES2300 38.9 2.3 140 82 32.5 2 117 69 26.7 1.6 96 57
Vane
ES2400 77.5 4.7 279 164 65.0 3.9 234 138 53.6 3.2 193 114
ES2500 153.3 9.2 552 325 130.0 7.8 468 275 106.1 6.4 382 225
ES2600 305.3 18.3 1099 647 260.0 15.6 936 551 210.9 12.7 759 447
For systems using 1 or 2 stage piston/reciprocating compressors multiply compressor flow by 1.4 and select a separator from screw
compressor flow rates shown, ensuring due consideration is given to oil type. For sizing at conditions other than those shown,
please contact Parker for correct product selection.
81
Condensate Management
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 20.6 1.2 74 43 17.2 1 62 36 14.2 0.9 51 30
ES2150 32.5 2 117 69 27.8 1.7 100 59 22.5 1.4 81 48
ES2200 50.3 3 181 106 42.5 2.6 153 90 34.7 2.1 125 73
Rotary Screw,
ES2300 70.3 4.2 253 149 59.2 3.5 213 125 48.6 2.9 175 103
Vane
ES2400 140.8 8.4 507 298 118.1 7.1 425 250 97.2 5.8 350 206
ES2500 278.6 16.7 1003 590 236.1 14.2 850 500 192.5 11.6 693 408
ES2600 554.2 33.3 1995 1174 472.0 28.3 1699 1000 383.1 23 1379 812
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 15.6 0.9 56 33 13.1 0.8 47 27 10.6 0.6 38 23
ES2150 24.4 1.5 88 52 20.8 1.3 75 44 16.9 1 61 36
ES2200 37.8 2.3 136 80 31.9 1.9 115 68 26.1 1.6 94 55
Rotary Screw,
ES2300 52.8 3.2 190 112 44.4 2.7 160 94 36.7 2.2 132 77
Vane
ES2400 105.8 6.3 381 224 88.9 5.3 320 188 73.1 4.4 263 155
ES2500 209.5 12.6 754 444 177.5 10.6 639 376 144.7 8.7 521 307
ES2600 416.4 25 1499 883 354.8 21.3 1277 751 287.8 17.3 1036 610
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 7.8 0.5 28 16 6.4 0.4 23 14 5.3 0.3 19 11
ES2150 12.2 0.7 44 26 10.6 0.6 38 22 8.6 0.5 31 18
ES2200 18.9 1.1 68 40 16.1 1 58 34 13.1 0.8 47 28
Rotary Screw,
ES2300 26.7 1.6 96 57 22.5 1.3 81 47 18.3 1.1 66 39
Vane
ES2400 53.3 3.2 192 113 44.7 2.7 161 95 36.9 2.2 133 78
ES2500 105.6 6.3 380 224 89.5 5.4 322 190 73.1 4.4 263 155
ES2600 210.0 12.6 756 445 178.9 10.7 644 379 145.3 8.7 523 308
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 6.4 0.4 23 13 5.3 0.3 19 11 4.4 0.3 16 9
ES2150 10.0 0.6 36 21 8.6 0.5 31 18 6.9 0.4 25 15
ES2200 15.3 0.9 55 33 13.1 0.8 47 28 10.6 0.6 38 22
Rotary Screw,
ES2300 21.7 1.3 78 46 18.1 1.1 65 38 15.0 0.9 54 32
Vane
ES2400 43.1 2.6 155 91 36.1 2.2 130 77 29.7 1.8 107 63
ES2500 85.3 5.1 307 181 72.2 4.3 260 153 58.9 3.5 212 125
ES2600 169.7 10.2 611 359 144.5 8.7 520 306 117.2 7 422 248
For systems using 1 or 2 stage piston/reciprocating compressors multiply compressor flow by 1.4 and select a separator from screw
compressor flow rates shown, ensuring due consideration is given to oil type. For sizing at conditions other than those shown,
please contact Parker for correct product selection.
82
www.parker.com/gsfe
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 10.3 0.6 37 22 8.6 0.5 31 18 7.2 0.4 26 15
ES2150 16.4 1 59 34 13.9 0.8 50 29 11.4 0.7 41 24
ES2200 25.0 1.5 90 53 21.4 1.3 77 45 17.2 1 62 37
Rotary Screw,
ES2300 35.3 2.1 127 75 29.4 1.8 106 63 24.4 1.5 88 52
Vane
ES2400 70.3 4.2 253 149 59.2 3.5 213 125 48.6 2.9 175 103
ES2500 139.2 8.4 501 295 118.1 7.1 425 250 96.4 5.8 347 204
ES2600 277.2 16.6 998 587 235.9 14.2 849 500 191.4 11.5 689 406
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 7.8 0.5 28 16 6.4 0.4 23 14 5.3 0.3 19 11
ES2150 12.2 0.7 44 26 10.6 0.6 38 22 8.6 0.5 31 18
ES2200 18.9 1.1 68 40 16.1 1 58 34 13.1 0.8 47 28
Rotary Screw,
ES2300 26.4 1.6 95 56 22.2 1.3 80 47 18.3 1.1 66 39
Vane
ES2400 52.8 3.2 190 112 44.4 2.7 160 94 36.7 2.2 132 77
ES2500 104.7 6.3 377 222 88.6 5.3 319 188 72.2 4.3 260 153
ES2600 208.4 12.5 750 441 177.2 10.6 638 376 143.9 8.6 518 305
Oil Type
No Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 3.9 0.2 14 8 3.3 0.2 12 7 2.8 0.2 10 6
ES2150 6.1 0.4 22 13 5.3 0.3 19 11 4.2 0.3 15 9
ES2200 9.4 0.6 34 20 8.1 0.5 29 17 6.7 0.4 24 14
Rotary Screw,
ES2300 13.3 0.8 48 28 11.1 0.7 40 24 9.2 0.6 33 20
Vane
ES2400 26.7 1.6 96 57 22.5 1.3 81 47 18.3 1.1 66 39
ES2500 52.8 3.2 190 112 44.7 2.7 161 95 36.4 2.2 131 77
ES2600 105.0 6.3 378 223 89.5 5.4 322 190 72.5 4.4 261 154
Oil Type
Refrigeration Dryer
Installed in System Band A Band B Band C
Turbine, Additive Free Mineral, PAO, TMP, PE Diesters, Triesters, PAG
Compressor Type Model L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm L/s m3/min m3/hr cfm
ES2100 3.1 0.2 11 7 2.5 0.2 9 6 2.2 0.1 8 5
ES2150 5.0 0.3 18 11 4.2 0.3 15 9 3.3 0.2 12 7
ES2200 7.8 0.5 28 16 6.4 0.4 23 14 5.3 0.3 19 11
Rotary Screw,
ES2300 10.8 0.6 39 23 9.2 0.5 33 19 7.5 0.4 27 16
Vane
ES2400 21.7 1.3 78 46 18.1 1.1 65 38 15.0 0.9 54 32
ES2500 42.5 2.6 153 90 36.1 2.2 130 77 29.4 1.8 106 62
ES2600 84.7 5.1 305 180 72.2 4.3 260 153 58.6 3.5 211 124
For systems using 1 or 2 stage piston/reciprocating compressors multiply compressor flow by 1.4 and select a separator from screw
compressor flow rates shown, ensuring due consideration is given to oil type. For sizing at conditions other than those shown,
please contact Parker for correct product selection.
83
Condensate Management
Each Separator model is sizeable to deliver a residual oil in water level of: When oil in
<20mg/L water levels
ES2100 - ES2600 Static <10mg/L exceed allowed
<5mg/L levels
Technical Data
Model ES2100 ES2150 ES2200 ES2300 ES2400 ES2500 ES2600
84
www.parker.com/gsfe
H H
D D W
W
ES2100 ES2150 to ES2600
85
Condensate Management
ED3007-G24D 2 x G½ G3/8 117 7 420 247 233 14 840 494 1167 70 4200 2472 24V DC
ED3030-G24D 2 x G½ G3/8 500 30 1800 1059 1000 60 3600 2119 5000 301 18000 10595 24V DC
ED3100-G24D 2 x G½ G3/8 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 24V DC
24V DC - 16 bar g (232 psi g)
ED4100/50-G230 G½ G¼ 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 230/1/50-60
230V/1PH/50-60Hz - 50 bar g (725 psi g)
ED4100/50-G24D G½ G¼ 1667 100 6000 3532 3334 200 12000 7063 16668 1002 60000 35316 24V DC
24V DC - 50 bar g (725 psi g)
Stated flows are for operation at max operating pressure shown above, ambient air 25°C (77°F) / 60% RH, compressor discharge temperature 35°C (95°F),
refrigeration dryer pressure dewpoint +3°C, with reference to 20°C, 1 bar (a), 0% relative water vapour pressure. Refrigeration dryer and filter flow rates
assume adequate condensate drainage upstream.
86
www.parker.com/gsfe
H
H
W D
HDF 220
H D
W D W
ED3002 ED3002-G230 -
ED3004 ED3004-G230 -
ED3007 ED3007-G230 ED3007-G24D
ED3030 ED3030-G230 ED3030-G24D
ED3100 ED3100-G230 ED3100-G24D
87
Thermal and Power Management
Maximum Pipe
Flow Rate
Model Operating Pressure Conn.
Standard Version
WFN050 3000 50 12 174 DN125 1¼"
Removable Tube-Bundle
WRN007 420 7 16 232 DN 50 ½"
Performances refer to clean cooler conditions with air at FAD 20°C / 1 bar A, and at the following working conditions: air suction 25°C / 60%RH,
7 bar g working pressure, 120°C compressed air inlet temperature, temperature approach between air outlet and water inlet of ca. 10°C. Maximum air inlet
temperature: 200°C (for higher temperatures and other gases contact Parker Sales Companies).
88
www.parker.com/gsfe
C B
B
B
½" BSP
(*)
A B C D Weight
Model
mm ins mm ins mm ins mm ins kg lbs
Standard Version
WFN090 1300 51.2 100 3.9 65 2.6 1990 78.3 121 266
Removable Tube-Bundle
WRN007 1050 41.3 72 2.8 77 3.0 1257 49.5 20 44
WRN090 1300 51.2 117 4.6 65 2.6 1873 73.7 161 354
WRN130 1300 51.2 116 4.6 71 2.8 1983 78.1 194 427
WRN170 1300 51.2 116 4.6 71 2.8 2053 80.8 244 537
WRN250 1500 59.1 196.5 7.7 71 2.8 2503 98.5 351 772
WRN350 1500 59.1 148.5 5.8 75 3.0 2703 106.4 400 880
WRN450 1500 59.1 199.5 7.9 78 3.1 3436 135.3 609 1340
WRN550 1515 59.6 200 7.9 83 3.3 3606 142.0 931 2048
89
Thermal and Power Management
Technical Data
Model ICEP 002-W 003-W 005-W 007-W 010-W 014-W 020-W 024-W 030-W 040-W 050-W 060-W
Cooling capacity 1
kW 1.7 3.3 5.2 7.8 10.8 14.6 20.3 23.6 29.7 40.6 49.0 58.3
Compressor abs. power 1
kW 0.7 1.3 1.4 1.7 2.5 3.2 4.4 5.4 5.7 7.5 10.0 12.3
SEPR3 4.58 4.50 5.00 5.00 5.22 5.30 5.02 5.02 5.00 5.13 5.12 5.11
V/ph/
Power supply 230/1/50 400/3/50
Hz
Protection index 33 54
Refrigerant R407c
Compressor
Type hermetic pistons scroll
Compressors / circuit 1/1
Max.abs. power1
kW 0.7 1.3 1.5 2.4 3.8 4.4 5.7 6.6 8.3 11.4 14.9 17.3
compressor
Axial Fans
Quantity n.° 1 1 1 1 1 1 2 2 2 2 2 2
Max. abs. power1 fan kW 0.07 0.12 0.12 0.3 0.3 0.4 0.4 0.4 0.45 0.69 0.69 0.69
Air flow m3/h 430 1295 1295 3437 3437 4337 6878 6159 9437 16029 15215 16875
Pump P30
Max.abs.power kW 0.4 0.4 0.4 0.9 0.9 1.0 1.3 1.3 1.3 2.2 2.2 2.2
Water flow (nom./max)1 m3/h 0.3/1.9 0.6/1.9 0.9/1.9 1.3/4.8 1.8/4.8 2.5/6 3.4/9.6 4.9/9.6 5.1/9.6 6.9/18 8.4/18 10.1/18
Head pressure (nom./max)1 m H2O 35/5 33/5 26/5 30/12.8 29/12.8 29/21 29/17.3 28/17.3 26/17.3 29/23.1 27/23.1 25/23.1
Noise level
Sound pressure (axial)2 dB(A) 52 52 52 53 53 50 50 50 51 52 52 53
1) At water in/out temperature 20/15°C, glycol 0%, either 25°C ambient temperature (air-cooled models) or 25°C condenser water inlet temperature with
35°C condensing temperature (water-cooled models).
2) Referred to axial fan version in free field conditions at a distance of 10 m from until, measured on condenser side, 1m from ground.
3) Value calculated in accordance with the European regulation (EU) 2016/2281 with regards to Ecodesign requirements for high temperature process
chillers.
As the manufacturer of process chillers delivering water at a design temperature of 15°C, Parker Hannifin Manufacturing s.r.l.,
Gas Separation and Filtration Division EMEA, declares that Parker chillers are exempt from Ecodesign EU regulation 2016/2281.
90
www.parker.com/gsfe
H H
W D W D
ICEP 002 ICEP 003-005
H H H
D D D
W W
W
ICEP 007-010-014 ICEP 020-030 ICEP 040-060
Correction Factors
A) Ambient Temperature °C 5 10 15 20 25 30 35 40 45
Correction Factor (f1) 1.05 1.05 1.05 1.05 1 0.94 0.89 0.84 0.80
To obtain the required cooling capacity, multiply the value at nominal conditions by the above correction factors (i.e. cooling
capacity = Pxf1xf2xf3xf4, where P is the cooling capacity at the water outlet temperature of 15°C). Hyperchill Plus, in its standard
configuration, can operate up to ambient temperatures of max. 48°C and min. 5°C and water temperatures of max. 30°C inlet and
min. 0°C outlet. The above correction factors are approximative: for a precise selection, always refer to the software selection
programme.
91
Thermal and Power Management
Power Supply
Low Ambient
Water Temp.
Water Tank
Condenser
Low Water
be Cooled
Antifreeze
Mounted
Options
Section
Fluid to
Control
Pumps
Fill Kit
Model
ICEP 002 - W A S P1 T C FS LW A 0 P
003 W T P3 0 0 L1 00 0 1 S
005 T P5 L2 2 D
007 B 00 00 3 C
010 C D3 1
014
W = Water S= T = With Tank LW = Low Water
020 230V/1Ph/50Hz
0 = Without 00 = NoLow
024 T= Tank Water
030 400V/3Ph/50Hz
040
A = Air Axial P1 = Single C = Close A = With
050 Pump 1.5 bar Control Antifreeze
W = Water +/- 0.5°C
060 P3 = Single 0 = Without
T = Tropicalised 0 = Without Antifreeze
Pump 3 bar
B = BioEnergy & Close Control
P5 = Single
Aggressive Pump 5 bar 0 = Without Fill Kit
Ambients FS = Fan Speed
ICEP = 00 = No Pump 1 = Ambient Manual
Hyperchill C = High Head Control (Low Fill Kit
Plus Pressure Fans D3 = Dual Pump Ambient -10°C)
3 bar 2 = Ambient Automatic
L1 = Low Fill Kit
Ambient -10°C
(Fan Step 3 = Pressurised
Control) Fill Kit
L2 = Low
Ambient -20°C P = Harting Plug For
Signals
00 = No Low
Ambient S = Siemens Electrical
Components
D = Differential Dynamic
Set Point
C = Control Panel Cover
1 = Manual External
Bypass
No Character = No
Versions Options Selected
ICEP002-W
ICEP003-W
ICEP005-W
ICEP010-W
ICEP014-W
ICEP020-W
ICEP024-W
ICEP030-W
ICEP040-W
ICEP050-W
ICEP060-W
ICEP007-W
Closed Circuit ● ● ● ● ● ● ● ● ● ●
Water Cooled ● ● ● ● ● ● ●
92
www.parker.com/gsfe
ICEP003-W
ICEP005-W
ICEP010-W
ICEP014-W
ICEP020-W
ICEP024-W
ICEP030-W
ICEP040-W
ICEP050-W
ICEP060-W
ICEP007-W
Differential pressure switch standard standard standard standard standard standard standard standard standard standard standard standard
MODBUS standard standard standard standard standard standard standard standard standard
No tank ● ● ● ● ● ● ● ● ● ● ● ●
No tank & no pump ● ● ● ● ● ● ● ● ● ● ● ●
No pump ● ● ● ● ● ● ● ● ● ● ● ●
P50 (5 bar pump) ● ● ● ● ● ● ● ● ● ● ●
P15 (1.5 bar pump) ● ● ● ● ● ● ● ● ●
Dual pump P30 (3 bar pump) ● ● ●
Harting plug ● ● ● ● ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ● ● ● ● ● ●
Low water -10°C ● ● ● ● ● ● ● ● ●
Tropicalization (53°C) ● ● ● ● ●
Differential dynamic set point ● ● ● ● ● ● ● ● ●
93
Thermal and Power Management
ICEP050-W
ICEP060-W
ICEP014-W
ICEP020-W
ICEP024-W
ICEP030-W
ICEP040-W
ICEP050-W
ICEP060-W
Differential pressure switch standard standard standard standard standard standard standard standard standard standard
MODBUS standard standard standard standard standard standard standard standard standard
No tank ● ● ● ● ● ● ● ● ● ●
No tank & no pump ● ● ● ● ● ● ● ● ● ●
No pump ● ● ● ● ● ● ● ● ● ●
P50 (5 bar pump) ● ● ● ● ● ● ● ● ● ●
P15 (1.5 bar pump) ● ● ● ● ● ● ● ● ●
Dual pump P30 (3 bar pump) ● ● ● ● ● ● ●
Harting plug ● ● ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ● ● ● ● ●
Low water -10°C ● ● ● ● ● ● ● ● ● ●
Antifreeze heating ● ● ● ● ● ● ● ● ● ●
Differential dynamic set point ● ● ●
94
www.parker.com/gsfe
Power Supply
Low Ambient
Water Temp.
Water Tank
Condenser
Low Water
be Cooled
Antifreeze
Mounted
Options
Section
Fluid to
Control
Pumps
Fill Kit
Model
ICEP 002 - W A F P1 T C FS 00 A 0 P
003 W G P3 0 0 L1 0 1 D
005 B P5 L2 2 C
007 00 00 3 1
010
W = Water F= T = With Tank 00 = No Low
014 230V/1Ph/60Hz Water
0 = Without
020 G= Tank
024 460V/3Ph/60Hz
ICEP003-W
ICEP005-W
ICEP010-W
ICEP014-W
ICEP020-W
ICEP024-W
ICEP007-W
Closed Circuit ● ● ● ● ● ●
Water Cooled ● ● ●
95
Thermal and Power Management
ICEP003-W
ICEP005-W
ICEP010-W
ICEP014-W
ICEP020-W
ICEP024-W
Differential pressure switch standard standard standard ICEP007-W
standard standard standard standard standard
No tank ● ● ● ● ● ● ● ●
No tank & no pump ● ● ● ● ● ● ● ●
No pump ● ● ● ● ● ● ● ●
P50 (5 bar pump) ● ● ● ● ● ● ●
P15 (1.5 bar pump) ● ● ● ● ●
Harting plug for signals ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ● ●
Low water -10°C ● ● ● ● ●
96
www.parker.com/gsfe
ICEP020 - ICEP030
ICEP040 - ICEP060
ICEP007 - ICEP014
ICEP002-W
ICEP003-W
ICEP005-W
Fill kit - ambient manual***
Non-ferrous ambient manual kits, 398H785314 398H785314 398H785314
for water filling in any installation.
Wheels
398H785302 398H785301 398H785301 398H785301
For ease of transport.
***From model ICEP007: ambient manual and automatic fill kit, pressurised automatic fill kit, control panel cover, manual external
bypass can be supplied already installed or loose.
97
Thermal and Power Management
Technical Data
Model ICE 076 090 116 150 183 230 310 360
Cooling capacity 1
kW 76.0 90.2 115.5 149.2 182.3 228 309 360
Compressor abs. power 1
kW 15.4 20.3 24.9 30.8 40.1 51.4 65 82
SEPR3 5.39 5.04 5.08 5.35 5.04 5.02 5.51 5.73
V/ph/
Power supply 400/3/50 no neutral
Hz
Protection index 54
Refrigerant R407C
Compressors
Type Hermetic scroll
Compressors/circuits 2/2 4/2
Max abs. power - 1 comp. kW 11.1 13.7 16.8 11.1 13.7 16.8 23.3 28.7
Axial Fans
Quantity n° 3 2 3 4
Max abs. power - 1 fan kW 0.78 0.78 0.78 2 2 2 2 2
Air flow m3/h 25500 25000 26400 47000 46000 66000 88000 88000
Centrifugal Fans
Quantity N° 3 3
Max abs. power - 1 fan kW 1.5 1.5 1.5 3 3 3
N.A.
Air flow m3/h 25500 25000 26400 47000 46000 66000
Head pressure Pa 100 100 100 180 180 130
Pump P30
Max abs.power kW 2.5 2.7 2.7 4.5 4.5 4.5 8.4 8.4
Water flow (nom/max)1 m3/h 13/31 15/27 20/27 25/50 30/50 39/50 53/90 62/90
Head pressure (nom/min)1 m H2O 23/13 28/16 25/16 34/20 32/20 26/20 26/19 23/19
Noise level
Sound pressure (axial)2 dB(A) 58 58 58 62 62 64 65 65
1) At water in/out temperature 20/15°C, glycol 0%, either 25°C ambient temperature (air-cooled models) or 25°C condenser water inlet temperature with
35°C condensing temperature (water-cooled models).
2) Referred to axial fan version in free field conditions at a distance of 10 m from until, measured on condenser side, 1m from ground.
3) Value calculated in accordance with the European regulation (EU) 2016/2281 with regards to Ecodesign requirements for high temperature process
chillers.
As the manufacturer of process chillers delivering water at a design temperature of 15°C, Parker Hannifin Manufacturing s.r.l.,
Gas Separation and Filtration Division EMEA, declares that Parker chillers are exempt from Ecodesign EU regulation 2016/2281.
98
www.parker.com/gsfe
ICE076-116 ICE230
H
H
D
D
W W
H H
D
D
W W
ICE150 - 183 ICE310-360
Correction Factors
A) Ambient Temperature
°C 5 10 15 20 25 30 35 40 45
(Air Cooled Models)
Correction Factor (f1) 1.05 1.05 1.05 1.05 1 0.95 0.89 0.83 0.77
C) Glycol % 0 10 20 30 40 50
To obtain the required cooling capacity multiply the value at nominal conditions by the above correction factors (i.e. cooling capacity
= Pxf1xf2xf3xf4, where P is the cooling capacity at conditions (1)). Hyperchill, in its standard configuration, can operate up to
ambient temperatures of max 45°C and min. 5°C and water temperatures of max 30°C inlet and min. 0°C outlet. The above correction
factors are approximative: for a precise selection always refer to the software selection programme.
99
Thermal and Power Management
Power Supply
Low Ambient
Water Temp.
Condenser
Low Water
Antifreeze
Hydraulic
Section
Control
Pumps
Circuit
Model
Versions
ICE076
ICE090
ICE116
ICE150
ICE183
ICE230
ICE310
ICE360
Water Cooled ● ● ● ● ● ●
100
www.parker.com/gsfe
ICE076 ICE076A4003501P30FF000000
ICE090 ICE090A4003501P30FF000000
ICE116 ICE116A4003501P30FF000000
ICE150 ICE150A4003501P30FF000000
ICE183 ICE183A4003501P30FF000000
ICE230 ICE230A4003501P30FF000000
ICE310 ICE310A4003501P30F00LA000
ICE360 ICE360A4003501P30F00LA000
ICE090
ICE116
ICE150
ICE183
ICE230
ICE310
ICE360
Water tank standard standard standard standard standard standard ● ●
Without tank standard standard
P30 (3 bar pump) standard standard standard standard standard standard ● ●
No pump ● ● ● ● ● ● standard standard
P50 (5 bar pump) ● ● ● ● ● ● ● ●
P15 (1.5 bar pump) ● ● ● ● ● ● on request on request
Dual pump P30 (3 bar pump) ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ●
Low water -10°C ● ● ● ● ● ● on request on request
101
Thermal and Power Management
ICE090
ICE116
ICE076
ICE090
ICE116
ICE150
ICE183
ICE230
Water tank standard standard standard standard standard standard standard standard standard
P30 (3 bar pump) standard standard standard standard standard standard standard standard standard
No pump ● ● ● ● ● ● ● ● ●
P50 (5 bar pump) ● ● ● ● ● ● ● ● ●
P15 (1.5 bar pump) ● ● ● ● ● ● ● ● ●
Dual pump P30 (3 bar pump) ● ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ● ● ● ●
Low water -10°C ● ● ● ● ● ● ● ● ●
Antifreeze heating ● ● ● ● ● ● ● ● ●
Non ferrous hydraulic circuit ● ● ● ● ● ● ● ● ●
102
www.parker.com/gsfe
Power Supply
Low Ambient
Water Temp.
Condenser
Low Water
Hydraulic
Options
Section
Control
Pumps
Circuit
Model
PCW110
PCW130
PCW160
PCW210
PCW260
PCW330
PCW420
PCW510
PCW650
Water tank standard standard standard standard standard standard standard standard standard standard
P30 (3 bar pump) standard standard standard standard standard standard standard standard standard standard
No pump ● ● ● ● ● ● ● ● ● ●
P50 (5 bar pump) ● ● ● ● ● ● ● ● ● ●
Close control (+/- 0.5°C) ● ● ● ● ● ● ● ● ● ●
Low water -10°C ● ● ● ● ● ● ● ● ● ●
Low ambient -10°C with
● ● ● ● ● ● ● ● ● ●
fan step control
103
Thermal and Power Management
As the manufacturer of process chillers delivering water at a design temperature of 15°C, Parker Hannifin Manufacturing s.r.l.,
Gas Separation and Filtration Division EMEA, declares that Parker chillers are exempt from Ecodesign EU regulation 2016/2281.
Correction Factors
A) Ambient Temperature °C 5 10 15 20 25 30 35 40 45
Correction Factor (f1) 1.05 1.05 1.05 1.05 1 0.95 0.89 0.83 0.77
To obtain the required cooling capacity multiply the value at nominal conditions by the above correction factors (i.e. cooling capacity
= Pxf1xf2xf3, where P is the cooling capacity at conditions (1). Hyperchill Laser, in its standard configuration, can operate up to
ambient temperatures of max 48 °C for ICEP models, 45°C for HLS models and min 5 °C and water temperatures of max 30 °C inlet
and min. 0°C outlet. The above correction factors are approximative: for a precise selection always refer to the software selection
program
104
www.parker.com/gsfe
D
W
HLS076-116
Power Supply
Low Ambient
Water Temp.
Condenser
Low Water
Antifreeze
Hydraulic
Section
Control
Pumps
Circuit
Model
HLS090
HLS116
HLS076
HLS090
HLS116
Close control (+/- 0.5°C) standard standard standard Fill kit ambient manual standard standard standard
P30 (3 bar pump) standard standard standard Remote control base 398H785010 398H785010 398H785010
Low ambient -10°C standard standard standard
Closed circuit 398H785011 398H785011 398H785011
Stainless steel with tank standard standard standard
Control panel cover 398H785089 398H785089 398H785089
Antifreeze heating ● ● ●
No pump ● ● ● Hydraulic bypass on request on request on request
105
Sizing andNitrogen
Industrial Selection
Gas
- Thermal
Generation
and Power Management
Prepared salads and vegetables, fresh chilled ready meals, meat, Typical applications include:
poultry, fish, dairy produce (including cheese), breads, coffee as • Belt furnaces
well as snack foods such as potato chips and nuts can all benefit • Batch furnaces
from ‘modified atmosphere packaging’ (or MAP as it is often
referred to). By using nitrogen gas from a Parker generator, the • Vacuum ovens
product shelf life is increased and the appearance and quite often • Brazing
taste, is also improved. • Carburising
Nitrogen is also used for ‘controlled atmosphere storage’ of fresh • Tempering
fruits and vegetables, sparging and blanketing food oils as well as • Annealing
bulk powders, cereals and liquid ingredients. • Gas quenching
Alcoholic and non-alcoholic drinks and ingredients can suffer • Neutral hardening
similar spoilage mechanisms to food, however one of the most • Normalising
significant threats to product quality is oxidisation which adversely
affects product taste. Beer and wine can absorb unwanted • Sintering
dissolved oxygen throughout the production process. Oxygen can
also reduce the effectiveness of natural or added vitamin C which Fire Prevention and Archive Protection
maybe used in fruit juices.
From the preservation of treasures for the generations after us, to
Nitrogen gas generators provide an ideal cost effective solution for preventing essential data destruction due to fire, Parker nitrogen
all of the processes involved in beverage production. generators provide a unique solution.
Oxygen depleted air can be pumped into buildings that house
Lasers treasures and archives or computer stored data to help prevent
Laser Cutting total loss caused by fire. Museum pieces, paintings, artefacts,
By far the largest use of nitrogen gas within this industry sector is furniture and valuable fabrics can all be protected.
for laser cutting. Nitrogen gas is used as an ‘assist gas’ to prevent In general, only a modest reduction in normal ambient oxygen
oxidisation or discolouration and to blow away the molten material levels is enough to prevent fire. At 16% oxygen content, archives
from the cut edge. are protected whilst intermittent human exposure to these levels
It is also used in certain types of laser cutting machine as a ‘purge will have no adverse effects.
gas’ to ensure the laser beam guide path from the resonator (where
106
www.parker.com/gsfe
The maximum remaining oxygen content required will vary with every application.
Maximum cost and energy savings = maximum oxygen level permissible
Compressor
NITROSource PSA
Nitrogen Gas Generator
CDAS HL Clean
Dry Air System
Nitrogen
Compressed Air
107
Industrial Nitrogen Gas Generation
Air Receiver
Compressor
NITROSource Compact
PSA Nitrogen
Gas Generator
K-MT Heatless
Compressed
Air Dryer Nitrogen
Compressed Air
Layout for food and pharmaceutical Nitrogen Storage Sterile Gas Filter
applications with sterile gas filtration
Nitrogen Buffer Vessel
Air Receiver
Compressor
NITROSource PSA
Nitrogen Gas Generator
FBP HL Oil-Free
Nitrogen
Air System
Compressed Air
108
www.parker.com/gsfe
Air Receiver
Compressor
40 barg
Nitrogen Storage
40 barg Booster
NITROSource PSA
Nitrogen Gas Generator
Nitrogen
CDAS HL Clean
Compressed Air
Dry Air System
Air Receiver
Compressor
High Pressure
Manifold Cylinder Pack
NITROSource PSA
Nitrogen Gas Generator
Nitrogen
CDAS HL Clean
Dry Air System Compressed Air
109
Industrial Nitrogen Gas Generation
Nitrogen
Compressed Air
Nitrogen
Compressed Air
110
www.parker.com/gsfe
Nitrogen
Compressed Air
Nitrogen
Compressed Air
111
Industrial Nitrogen Gas Generation
Technical Data
Nitrogen Flow Rates m3/hr vs Purity (Oxygen Content)
N2-20P 3.5 4.5 6.7 8.0 9.7 11.1 12.4 16.7 17.7 21.3 25.3 29.8 30.9 33.7
N2-25P 5.3 6.8 10.1 12.0 14.6 16.7 18.6 25.1 26.6 32.0 38.0 44.7 46.4 50.6
N2-35P 7.0 9.0 13.4 16.0 19.4 22.2 24.8 33.4 35.4 42.6 50.6 59.6 61.8 67.4
N2-45P 8.8 11.3 16.8 20.0 24.3 27.8 31.0 41.8 44.3 53.3 63.3 74.5 77.3 84.3
N2-55P 10.5 13.5 20.1 24.0 29.1 33.3 37.2 50.1 53.1 63.9 75.9 89.4 92.7 101.1
N2-60P 11.6 15.0 22.3 26.6 32.3 36.9 41.2 55.5 58.9 70.8 84.1 99.1 102.7 112.1
N2-65P 13.3 17.1 25.5 30.4 36.9 42.2 47.1 63.5 67.3 80.9 96.1 113.2 117.4 128.1
N2-75P 14.5 18.6 27.7 33.1 40.2 46.0 51.3 69.1 73.3 88.2 104.7 123.4 127.9 139.5
N2-80P 16.1 20.7 30.8 36.8 44.6 51.1 57.0 76.8 81.4 98.0 116.4 137.1 142.1 155.0
Performance data is based on 7 bar g air inlet pressure and 20°C - 25°C ambient temperature. Consult Parker for performance under
specific conditions.
m3 reference standard 20°C, 1013 millibar(a), 0% relative water vapour pressure.
Energy Saving
Product Code
Technology
N2-20P 250
N2-25P 500
N2 - 20 P X L N
25 A M Y N2-35P 500
35 B H
N2-45P 750
45
N = Does Not
60 Include EST N2-55P 750
55 X = Ultra High Purity Y = Includes EST
N2-60P 750
65 (≤10ppm)
L = Low Flow
75 A = High Purity (ppm) (0-60 m³/hr) N2-65P 1000
80 B = Low Purity (%) M = Medium Flow
(60-120 m³/hr) N2-75P 1000
N2 = P = Pressure Swing H = High Flow
NITROSource Adsorption (PSA) (120-300 m³/hr) N2-80P 1000
112
www.parker.com/gsfe
W D
Kit Contents
Part Number Description / Service Interval Contents
Flowrate
Model Units 10PPM 50PPM 100PPM 250PPM 500PPM 0.1% 0.5% 1% 2% 3% 4% 5%
m3/hr 0.81 1.24 1.54 1.77 2.09 2.48 3.69 4.39 6.11 7.73 9.13 10.29
N2C-2
cfm 0.5 0.7 0.9 1.0 1.2 1.5 2.2 2.6 3.6 4.5 5.4 6.1
m3/hr 1.73 2.38 2.94 3.52 4.21 4.96 7.58 9.12 12.95 15.89 18.38 20.57
N2C-4
cfm 1.0 1.4 1.7 2.1 2.5 2.9 4.5 5.4 7.6 9.4 10.8 12.1
m3/hr 2.41 3.91 4.46 5.66 6.50 7.59 11.06 13.32 18.64 22.68 26.06 29.04
N2C-6
cfm 1.4 2.3 2.6 3.3 3.8 4.5 6.5 7.8 11.0 13.3 15.3 17.1
m3/hr 3.38 5.01 5.89 7.35 8.68 10.24 14.86 18.01 24.02 29.33 33.93 37.81
N2C-8
cfm 2.0 2.9 3.5 4.3 5.1 6.0 8.7 10.6 14.1 17.3 20.0 22.3
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 25 °C
Outlet Version
Product Code
Flow Control
Technology
Maximum
O2 Purity
Model
N2C - 2 N C A L N
4 B A
6
8 C = Constant N=
No Analyser
A = Analyser
N2C = NITROSource N = Non Equalising A = High Purity (ppm)
Compact
B = Low Purity (%)
L = Low Pressure
(6 - 10 bar g)
114
www.parker.com/gsfe
D
W
115
Industrial Nitrogen Gas Generation - Membrane Modules
SmartFluxx SA604
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical Nitrogen1) flow rate Typical Feed-air consumption at nitrogen flow rate
Purity % in m3/hr2) (SCFM) Purity % in m3/hr2) (SCFM)
99.5 99.0 98.0 97.0 96.0 95.0 99.5 99.0 98.0 97.0 96.0 95.0
4 bar g 0.20 0.32 0.50 0.73 0.84 1.04 4 bar g 1.9 1.8 1.9 2.3 2.3 2.5
(58 psi g) (0.12) (0.19) (0.29) (0.43) (0.49) (0.61) (58 psi g) (1.1) (1.1) (1.1) (1.4) (1.4) (1.5)
5 bar g 0.28 0.46 0.73 0.92 1.17 1.54 5 bar g 2.2 2.3 2.6 2.7 3.0 3.6
(72.5 psi g) (0.16) (0.27) (0.43) (0.54) (0.69) (0.91) (72.5 psi g) (1.3) (1.4) (1.5) (1.6) (1.8) (2.1)
6 bar g 0.44 0.60 0.92 1.20 1.53 1.75 6 bar g 2.5 2.8 3.2 3.4 3.9 4.0
(87 psi g) (0.21) (0.35) (0.54) (0.71) (0.9) (1.03) (87 psi g) (1.5) (1.6) (1.9) (2) (2.3) (2.4)
7 bar g 0.44 0.71 1.16 1.49 1.90 2.10 7 bar g 3.0 3.3 3.9 4.2 4.8 4.7
(101.5 psi g) (0.26) (0.42) (0.68) (0.88) (1.12) (1.24) (101.5 psi g) (1.8) (1.9) (2.3) (2.5) (2.8) (2.8)
8 bar g 0.54 0.85 1.31 1.75 2.17 2.60 8 bar g 3.5 3.8 4.4 4.9 5.4 5.8
(116 psi g) (0.32) (0.5) (0.77) (0.77) (1.28) (1.53) (116 psi g) (2.1) (2.2) (2.6) (2.9) (3.2) (3.4)
9 bar g 0.59 0.97 1.54 2.08 2.50 3.00 9 bar g 3.7 4.3 5.1 5.8 6.3 6.7
(130.5 psi g) (0.35) (0.57) (0.91) (1.22) (1.47) (1.77) (130.5 psi g) (2.2) (2.5) (3) (3.4) (3.7) (3.9)
10 bar g 0.67 1.11 1.78 2.29 2.80 3.40 10 bar g 4.1 4.8 5.9 6.3 7.0 7.5
(145 psi g) (0.39) (0.65) (1.05) (1.35) (1.65) (2) (145 psi g) (2.4) (2.8) (3.5) (3.7) (4.1) (4.4)
11 bar g 0.73 1.25 1.95 2.57 3.20 3.90 11 bar g 4.4 5.3 6.3 7.1 7.9 8.5
(159.5 psi g) (0.43) (0.74) (1.15) (1.51) (1.88) (2.3) (159.5 psi g) (2.6) (3.1) (3.7) (4.2) (4.6) (5)
12 bar g 0.79 1.39 2.17 2.80 3.40 4.20 12 bar g 4.6 5.9 7.0 7.7 8.4 9.3
(174 psi g) (0.46) (0.82) (1.28) (1.65) (2) (2.47) (174 psi g) (2.7) (3.5) (4.1) (4.5) (4.9) (5.5)
13 bar g 0.89 1.49 2.40 3.10 3.80 4.80 13 bar g 5.5 6.4 7.9 8.7 9.5 10.7
(188.5 psi g) (0.52) (0.88) (1.41) (1.82) (2.24) (2.83) (188.5 psi g) (3.2) (3.8) (4.6) (5.1) (5.6) (6.3)
Maximum pressure drop <0.1 bar.
Values between brackets are indicative imperial values
1) The above data represents the typical performance of a single membrane module. Actual performance can vary depending on factors such as feed air pressure and temperature. Please
contact your Parker go to person for actual performance information to meet your application’s requirements.
2) m3/hr refers to conditions at 1013 mbar(a) and 20°C.
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
116
www.parker.com/gsfe
SmartFluxx SA708
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical Nitrogen1) flow rate Typical Feed-air consumption at nitrogen flow rate
Purity % in m3/hr2) (SCFM) Purity % in m3/hr2) (SCFM)
99.5 99 98 97 96 95 93 90 99.5 99 98 97 96 95 93 90
4 bar g 0.90 1.44 2.20 2.91 3.63 4.36 4 bar g 7.5 8.6 9.0 9.5 10.4 11.2
(58 psi g) (0,53) (0,85) (1,3) (1,71) (2,14) (2,57) (58 psi g) (4,4) (5,1) (5,3) (5,6) (6,1) (6,6)
5 bar g 1.3 2.06 3.09 4.05 5.10 6.15 5 bar g 10.1 11.5 11.7 12.6 14.0 15.2
(72.5 psi g) (0,77) (1,21) (1,82) (2,38) (3) (3,62) (72.5 psi g) (6) (6,7) (6,9) (7,4) (8,2) (8,9)
6 bar g 1.71 2.67 3.99 5.18 6.56 7.94 11.3 18.2 6 bar g 12.3 13.8 14.2 15.3 17.1 18.8 22.6 29.9
(87 psi g) (1) (1,57) (2,35) (3,05) (3,86) (4,67) (6,62) (10,7) (87 psi g) (7,2) (8,1) (8,4) (9) (10,1) (11,1) (13,3) (17,6)
7 bar g 2.11 3.27 4.90 6.46 8.12 9.78 13.8 22.1 7 bar g 14.7 16.2 17.1 18.7 20.8 22.7 27.1 36.0
(101.5 psi g) (1,24) (1,93) (2,89) (3,8) (4,78) (5,76) (8,1) (13) (101.5 psi g) (8,6) (9,6) (10) (11) (12,2) (13,4) (16) (21,2)
8 bar g 2.50 3.87 5.82 7.73 9.67 11.6 16.4 26.6 8 bar g 16.5 18.5 19.7 21.9 24.4 26.5 31.8 42.8
(116 psi g) (1,47) (2,28) (3,42) (4,55) (5,69) (6,84) (9,63) (15,7) (116 psi g) (9,7) (10,9) (11,6) (12,9) (14,4) (15,6) (18,7) (25,2)
9 bar g 2.81 4.46 6.77 9.03 11.27 13.5 19.0 30.8 9 bar g 18.5 21.1 22.7 25.6 28.3 30.6 36.8 49.4
(130.5 psi g) (1,66) (2,62) (3,98) (5,32) (6,63) (7,95) (11,2) (18,1) (130.5 psi g) (10,9) (12,4) (13,4) (15,1) (16,7) (18) (21,6) (29,1)
10 bar g 3.12 4.94 7.64 10.3 12.9 15.4 21.7 35.6 10 bar g 20.4 23.2 25.5 29.2 32.1 34.8 42.0 57.2
(145 psi g) (1,84) (2,91) (4,5) (6,08) (7,57) (9,06) (12,8) (21) (145 psi g) (12) (13,7) (15) (17,2) (18,9) (20,5) (24,7) (33,7)
11 bar g 3.41 5.46 8.49 11.5 14.5 17.3 11 bar g 22.1 25.5 28.3 32.4 36.1 39.0
(159.5 psi g) (2) (3,21) (5) (6,78) (8,51) (10,2) (159.5 psi g) (13) (15) (16,6) (19,1) (21,2) (23)
12 bar g 3.68 5.96 9.32 12.5 15.9 19.1 12 bar g 24.1 27.9 31.3 35.5 39.8 43.3
(174 psi g) (2,16) (3,51) (5,49) (7,38) (9,35) (11,2) (174 psi g) (14,2) (16,4) (18,4) (20,9) (23,4) (25,5)
13 bar g 3.93 6.45 10.1 13.6 17.1 20.9 13 bar g 25.9 30.9 34.3 38.8 43.2 47.8
(188.5 psi g) (2,32) (3,8) (5,92) (7,98) (10,1) (12,3) (188.5 psi g) (15,3) (18,2) (20,2) (22,8) (25,5) (28,1)
Maximum pressure drop at Purity <0.2 bar
Values between brackets are indicative of imperial values
1) The above data represents the typical performance of a single membrane module. Actual performance can vary depending on factors such as feed air pressure and temperature. Please
contact your Parker go to person for actual performance information to meet your application’s requirements.
2)
m3/hr refers to conditions at 1013mbar(a) and 20°C.
For purities >99.5% please contact Parker
Material
Feed-air Conditions
Housing Aluminum
Maximum operating pressure 13.0 bar g (190 psi g)
ESPC to RAL 7039 (Quartz Grey)
Min. / Max. operating temperature +2°C / +50°C (+36°F to 122°F) Coating
Dry Film Thickness: 60 micron
Maximum oil vapour content <0.01 mg/m3 (<0.01 ppm (w))
Particles filtered at 0.01 µm cut off Services on Request
Relative humidity <100% (non condensing) 3D model CAD STEP file
SmartFluxx SA1508
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical Nitrogen1) flow rate Typical Feed-air consumption at nitrogen flow rate
Purity % in m3/hr2) (SCFM) Purity % in m3/hr2) (SCFM)
99.5 99.0 98.0 97.0 96.0 95.0 99.5 99.0 98.0 97.0 96.0 95.0
4 bar g 2.8 4.0 5.7 7.1 9.5 10.9 4 bar g 21 21 22 22 26 27
(58 psi g) (1.6) (2.4) (3.4) (4.2) (5.6) (6.4) (58 psi g) (12) (12) (13) (13) (15) (16)
5 bar g 3.7 5.3 7.9 10.2 12.8 15.2 5 bar g 24 26 29 31 34 36
(72.5 psi g) (2.2) (3.1) (4.6) (6) (7.5) (8.9) (72.5 psi g) (14) (15) (17) (18) (20) (21)
6 bar g 4.7 7.0 10.2 13.0 15.7 20.5 6 bar g 29 33 36 38 41 48
(87 psi g) (2.8) (4.1) (6) (7.7) (9.2) (12.1) (87 psi g) (17) (19) (21) (22) (24) (28)
7 bar g 6.1 8.5 12.3 16.5 19.5 24.3 7 bar g 36 38 41 48 50 56
(101.5 psi g) (3.6) (5) (7.2) (9.7) (11.5) (14.3) (101.5 psi g) (21) (22) (24) (28) (29) (33)
8 bar g 6.9 9.7 14.3 20.2 23.3 28.1 8 bar g 38 42 47 56 58 63
(116 psi g) (4.1) (5.7) (8.4) (11.9) (13.7) (16.5) (116 psi g) (22) (25) (28) (33) (34) (37)
9 bar g 7.8 11.1 17.0 22.2 27.0 32.2 9 bar g 44 48 55 62 67 72
(130.5 psi g) (4.6) (6.5) (10) (13.1) (15.9) (19) (130.5 psi g) (26) (28) (32) (36) (39) (42)
10 bar g 8.6 12.6 18.5 24.2 30.2 37.4 10 bar g 50 56 61 68 75 84
(145 psi g) (5.1) (7.4) (10.9) (14.2) (17.8) (22) (145 psi g) (29) (33) (36) (40) (44) (49)
11 bar g 9.6 14.2 20.7 27.3 33.0 41.0 11 bar g 51 60 66 74 80 91
(159.5 psi g) (5.7) (8.4) (12.2) (16.1) (19.4) (24.1) (159.5 psi g) (30) (35) (39) (44) (47) (54)
12 bar g 10.5 15.2 22.9 29.5 36.6 45.6 12 bar g 57 65 76 83 92 103
(174 psi g) (6.2) (8.9) (13.5) (17.4) (21.5) (26.8) (174 psi g) (34) (38) (45) (49) (54) (61)
13 bar g 11.3 16.3 24.9 32.0 39.5 48.8 13 bar g 66 72 85 92 101 113
(188.5 psi g) (6.7) (9.6) (14.7) (18.8) (23.2) (28.7) (188.5 psi) (39) (42) (50) (54) (59) (67)
Maximum pressure drop at Purity <0.2 bar
Values between brackets are indicative of imperial values
1) The above data represents the typical performance of a single membrane module.
Actual performance can vary depending on factors such as feed air pressure and
Mechanical Design Housing
temperature. Please contact your Parker go to person for actual performance information Design pressure 15 bar g4) (217 psi g)4)
to meet your application’s requirements.
2) m3/hr refers to conditions at 1013 mbar(a) and 20°C
Design temperature 65ºC4) (149ºF)4)
For purities >99.5% please contact Parker
4)
Membrane ambient and operating conditions are lower
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
118
www.parker.com/gsfe
SmartFluxx SA1508SS
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical Nitrogen1) flow rate Typical Feed-air consumption at nitrogen flow rate
Purity % in m3/hr2) (SCFM) Purity % in m3/hr2) (SCFM)
99.5 99.0 98.0 97.0 96.0 95.0 99.5 99.0 98.0 97.0 96.0 95.0
4 bar g 2.8 4.0 5.7 7.1 9.5 10.9 4 bar g 21 21 22 22 26 27
(58 psi g) (1.6) (2.4) (3.4) (4.2) (5.6) (6.4) (58 psi g) (12) (12) (13) (13) (15) (16)
5 bar g 3.7 5.3 7.9 10.2 12.8 15.2 5 bar g 24 26 29 31 34 36
(72.5 psi g) (2.2) (3.1) (4.6) (6) (7.5) (8.9) (72.5 psi g) (14) (15) (17) (18) (20) (21)
6 bar g 4.7 7.0 10.2 13.0 15.7 20.5 6 bar g 29 33 36 38 41 48
(87 psi g) (2.8) (4.1) (6) (7.7) (9.2) (12.1) (87 psi g) (17) (19) (21) (22) (24) (28)
7 bar g 6.1 8.5 12.3 16.5 19.5 24.3 7 bar g 36 38 41 48 50 56
(101.5 psi g) (3.6) (5) (7.2) (9.7) (11.5) (14.3) (101.5 psi g) (21( (22) (24) (28) (29) (33)
8 bar g 6.9 9.7 14.3 20.2 23.3 28.1 8 bar g 38 42 47 56 58 63
(116 psi g) (4.1) (5.7) (8.4) (11.9) (13.7) (16.5) (116 psi g) (22) (25) (28 (33) (34) (37)
9 bar g 7.8 11.1 17.0 22.2 27.0 32.2 9 bar g 44 48 55 62 67 72
(130.5 psi g) (4.6) (6.5) (10) (13.1) (15.9) (19) (130.5 psi g) (26) (28) (32) (36) (39) (42)
10 bar g 8.6 12.6 18.5 24.2 30.2 37.4 10 bar g 50 56 61 68 75 84
(145 psi g) (5.1) (7.4) (10.9) (14.2) (17.8) (22) (145 psi g) (29) (33) (36) (40) (75) (44)
11 bar g 9.6 14.2 20.7 27.3 33.0 41.0 11 bar g 51 60 66 74 80 91
(159.5 psi g) (5.7) (8.4) (12.2) (16.1) (19.4) (24.1) (159.5 psi g) (30) (35) (39) (44) (47) (54)
12 bar g 10.5 15.2 22.9 29.5 36.6 45.6 12 bar g 57 65 76 83 92 103
(174 psi g) (6.2) (8.9) (13.5) (17.4) (21.5) (26.8) (174 psi g) (34) (38) (45) (49) (54) (61)
13 bar g 11.3 16.3 24.9 32.0 39.5 48.8 13 bar g 66 72 85 92 101 113
(188.5 psi g) (6.7) (9.6) (14.7) (18.8) (23.2) (28.7) (188.5 psi g) (39) (42) (50) (54) (59) (67)
Maximum pressure drop at Purity <0.2 bar
Values between brackets are indicative of imperial values
1) The above data represents the typical performance of a single membrane module. Actual
performance can vary depending on factors such as feed air pressure and temperature.
Mechanical Design Housing
Please contact your Parker go to person for actual performance information to meet your Design pressure 15 bar g4) (217 psi g)4)
application’s requirements.
2) m3/hr refers to conditions at 1013 mbar(a) and 20°C Design temperature 65ºC4) (149ºF)4)
For purities >99.5% please contact Parker 4)
Membrane operating limits are lower
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
119
Industrial Nitrogen Gas Generation - Membrane Modules
SmartFluxx SA15015
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical1) Nitrogen flow rate in m3/hr 2) (SCFM) Typical Feed-air consumption at nitrogen flow rate in m3/hr 2) (SCFM)
Purity % Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 21.8 29.6 37.4 48.4 59.5 4 bar g 116 116 120 141 155
(58 psi g) (12.8) (17.4) (22.0) (28.5) (35.0) (58 psi g) (68) (69) (71) (83) (91)
5 bar g 29.5 42.5 55.5 69.4 83.2 5 bar g 152 164 176 198 211
(73 psi g) (17.3) (25.0) (32.7) (40.8) (49.0) (73 psi g) (90) (96) (104) (116) (124)
6 bar g 36.8 54.6 72.3 89.1 105.9 6 bar g 186 206 226 249 262
(87 psi g) (21.7) (32.1) (42.6) (52.5) (62.4) (87 psi g) (109) (121) (133) (147) (154)
7 bar g 43.9 65.8 87.8 107.8 127.7 7 bar g 216 244 270 296 299
(102 psi g) (25.8) (38.8) (51.7) (63.4) (75.2) (102 psi g) (127) (143) (159) (174) (176)
8 bar g 50.7 76.3 102.0 125.3 148.6 8 bar g 244 278 309 338 347
(116 psi g) (29.8) (44.9) (60.0) (73.7) (87.5) (116 psi g) (144) (163) (182) (199) (204)
9 bar g 57.2 86.0 114.8 141.6 168.5 9 bar g 271 308 342 376 392
(130 psi g) (33.6) (50.6) (67.6) (83.4) (99.2) (130 psi g) (159) (181) (201) (221) (231)
10 bar g 63.3 94.8 126.4 156.9 187.4 10 bar g 298 334 371 410 431
(145 psi g) (37.3) (55.8) (74.4) (92.3) (110.3) (145 psi g) (175) (197) (218) (241) (254)
11 bar g 69.2 102.9 136.6 171.0 205.4 11 bar g 325 360 396 445 472
(160 psi g) (40.7) (60.6) (80.4) (100.6) (120.9) (160 psi g) (191) (212) (233) (262) (278)
12 bar g 74.8 110.1 145.5 183.9 222.4 12 bar g 352 386 422 478 511
(174 psi g) (44.0) (64.8) (85.6) (108.3) (130.9) (174 psi g) (207) (227) (248) (281) (301)
13 bar g 80.1 116.6 153.1 195.8 238.5 13 bar g 376 408 444 509 548
(189 psi g) (47.1) (68.6) (90.1) (115.2) (140.3) (189 psi g) (222) (240) (261) (300) (323)
Maximum pressure drop at Purity: ≤0.2 bar
Values between brackets are indicative imperial values
The above data represents the typical performance of a single membrane module. Actual
1)
m3/hr refers to conditions at 1013 mbar(a) and 20°C
2)
performance can vary depending on factors such as feed air condition and is depending on Performance certificates available up to 11 barg.
3)
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
120
www.parker.com/gsfe
SmartFluxx SA15020
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical Nitrogen1) flow rate Typical Feed-air consumption at
Purity % in m3/hr2) (SCFM) Purity % nitrogen flow rate in m3/hr2) (SCFM)
99.5 99.0 98.0 97.0 96.0 95.0 99.5 99.0 98.0 97.0 96.0 95.0
4 bar g 17 25 36 47 57 70 4 bar g 127 126 135 145 155 169
(58 psi g) (10) (15) (21) (28) (34) (41) (58 psi g) (75) (74) (79) (85) (91) (99)
5 bar g 23 33 49 66 82 93 5 bar g 144 155 171 194 216 218
(72.5 psi g) (14) (19) (29) (39) (48) (55) (72.5 psi g) (85) (91) (101) (114) (127) (128)
6 bar g 29 43 63 83 102 120 6 bar g 170 191 214 239 261 276
(87 psi g) (17) (25) (37) (49) (60) (71) (87 psi g) (100) (112) (126) (141) (154) (162)
7 bar g 37 53 78 100 125 154 7 bar g 202 223 258 281 315 348
(101.5 psi g) (22) (31) (46) (59) (74) (91) (101.5 psi g) (119) (131) (152) (165) (185) (205)
8 bar g 44 62 90 117 144 178 8 bar g 232 255 293 323 361 399
(116 psi g) (26) (36) (53) (69) (85) (105) (116 psi g) (137) (150) (172) (190) (212) (235)
9 bar g 49 72 103 133 165 216 9 bar g 264 298 335 369 413 485
(130.5 psi g) (29) (42) (61) (78) (97) (127) (130.5 psi g) (155) (175) (197) (217) (243) (285)
Maximum pressure drop at Purity: ≤0.2 bar
Values between brackets are indicative imperial values”
The above data represents the typical performance of a single membrane module. Actual performance can vary depending on factors such as feed air pressure and temperature.
1)
Please contact your Parker go to person for actual performance information to meet your application’s requirements.
m3/hr refers to conditions at 1013 mbar(a) and 20°C
2)
Min. / Max. operating temperature +2°C to +50°C (+36°F to 122°F) ESPC to RAL 7039 (Quartz Grey)
Coating
Dry Film Thickness: 60 micron
Maximum oil vapour content <0.01 mg/m (<0.01 ppm (w))
3
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
121
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx ST304
H D
Purity Typical1) Nitrogen flow rate in m3/hr2) (SCFM) Typical Feed-air consumption at nitrogen flow rate in m3/hr2) (SCFM)
Purity %
%1 99 98 97 96 95 99 98 97 96 95
4 bar g 0.15 0.27 0.39 0.50 0.62 4 bar g 1.16 1.29 1.43 1.54 1.69
5 bar g 0.19 0.34 0.48 0.62 0.78 5 bar g 1.44 1.61 1.78 1.92 2.11
6 bar g 0.25 0.45 0.62 0.80 0.98 6 bar g 1.73 1.98 2.18 2.39 2.65
7 bar g 0.29 0.52 0.73 0.93 1.14 7 bar g 2.02 2.31 2.55 2.79 3.09
8 bar g 0.33 0.60 0.83 1.06 1.31 8 bar g 2.31 2.64 2.91 3.19 3.53
9 bar g 0.39 0.70 0.95 1.23 1.52 9 bar g 2.70 3.06 3.33 3.69 4.10
10 bar g 0.41 0.75 1.04 1.33 1.64 10 bar g 2.89 3.30 3.64 3.99 4.42
11 bar g 0.43 0.82 1.15 1.48 1.83 11 bar g 3.45 3.85 4.24 4.58 4.94
12 bar g 0.45 0.89 1.25 1.63 2.02 12 bar g 3.60 4.17 4.63 5.04 5.46
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100%. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013 mbar(a) and 20°C
Relative humidity <100% (non condensing) Connection inlet / outlet G3/8 female
*Maximum inlet temperature, 35˚C when operating at 13 bar g. Vent G3/8 female
**Maximum inlet pressure, 10 bar g when operating at 45˚C. Dimensional drawing Refer to K3.1.348
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
122
www.parker.com/gsfe
HiFluxx DT304
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical1) Nitrogen flow rate in m3/hr2) (SCFM) Typical Feed-air consumption at nitrogen flow rate in m3/hr2) (SCFM)
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 0.29 0.47 0.75 1.00 1.26 1.55 4 bar g 2.56 2.78 3.16 3.41 3.77 4.03
5 bar g 0.36 0.59 0.94 1.25 1.57 1.94 5 bar g 3.20 3.47 3.95 4.26 4.72 5.04
6 bar g 0.47 0.75 1.19 1.61 2.00 2.43 6 bar g 3.93 4.29 4.89 5.30 5.80 6.32
7 bar g 0.55 0.88 1.39 1.87 2.33 2.84 7 bar g 4.58 5.00 5.70 6.18 6.76 7.37
8 bar g 0.62 1.00 1.59 2.14 2.67 3.24 8 bar g 5.24 5.72 6.52 7.06 7.73 8.43
9 bar g 0.71 1.14 1.79 2.44 3.03 3.68 9 bar g 5.93 6.53 7.33 8.05 8.78 9.57
10 bar g 0.78 1.25 1.99 2.68 3.33 4.05 10 bar g 6.55 7.14 8.15 8.83 9.66 10.5
11 bar g 0.83 1.35 2.14 2.89 3.63 4.44 11 bar g 7.50 8.13 9.22 10.1 10.9 11.5
12 bar g 0.89 1.46 2.30 3.11 3.94 4.83 12 bar g 7.99 8.73 9.89 10.9 11.8 12.5
Maximum pressure drop <0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100%. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013 mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
123
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx TT304
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 0.50 0.74 1.13 1.49 1.79 2.28 4 bar g 3.82 4.17 4.63 5.06 5.37 5.92
5 bar g 0.62 0.93 1.41 1.86 2.24 2.85 5 bar g 4.78 5.21 5.79 6.33 6.71 7.40
6 bar g 0.77 1.17 1.78 2.36 2.93 3.55 6 bar g 5.93 6.46 7.12 7.78 8.48 9.23
7 bar g 0.90 1.37 2.08 2.75 3.41 4.14 7 bar g 6.92 7.53 8.30 9.07 9.90 10.8
8 bar g 1.03 1.57 2.37 3.14 3.90 4.73 8 bar g 7.91 8.61 9.49 10.4 11.3 12.3
9 bar g 1.16 1.73 2.66 3.54 4.45 5.39 9 bar g 9.01 9.71 10.9 11.7 12.9 14.0
10 bar g 1.28 1.96 2.97 3.93 4.88 5.92 10 bar g 10.0 11.0 12.2 13.0 14.1 15.4
11 bar g 1.36 2.07 3.19 4.25 5.32 6.48 11 bar g 11.6 12.4 13.7 14.9 16.0 17.5
12 bar g 1.43 2.18 3.41 4.57 5.77 7.05 12 bar g 12.2 13.1 14.7 16.0 17.3 19.0
Maximum pressure drop < 0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100%. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013 mbar(a) and 20°C
*Revision number may vary, make sure to use the most recent Revision
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
124
www.parker.com/gsfe
HiFluxx ST504
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %1
99 98 97 96 95 99 98 97 96 95
4 bar g 0.20 0.33 0.47 0.61 0.75 4 bar g 1.57 1.70 1.84 2.01 2.17
5 bar g 0.27 0.46 0.65 0.84 1.03 5 bar g 1.94 2.12 2.37 2.63 2.82
6 bar g 0.36 0.60 0.83 1.07 1.31 6 bar g 2.38 2.56 3.00 3.31 3.53
7 bar g 0.41 0.71 1.01 1.29 1.57 7 bar g 2.78 3.06 3.54 3.81 4.17
8 bar g 0.48 0.83 1.18 1.52 1.86 8 bar g 3.24 3.55 4.13 4.45 4.91
9 bar g 0.55 0.95 1.35 1.75 2.14 9 bar g 3.73 4.06 4.72 5.12 5.66
10 bar g 0.62 1.07 1.52 1.96 2.39 10 bar g 4.23 4.60 5.33 5.77 6.35
11 bar g 0.68 1.19 1.69 2.17 2.65 11 bar g 4.78 5.19 5.97 6.46 7.06
12 bar g 0.75 1.30 1.86 2.38 2.90 12 bar g 5.39 5.83 6.64 7.21 7.78
13 bar g 0.81 1.42 2.04 2.59 3.15 13 bar g 6.07 6.55 7.36 8.03 8.53
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%.
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100%. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013 mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
125
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx ST604
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 0.39 0.65 0.88 1.11 1.40 4 bar g 2.47 2.80 3.09 3.34 3.63
5 bar g 0.48 0.81 1.10 1.39 1.74 5 bar g 3.08 3.50 3.86 4.17 4.53
6 bar g 0.61 1.05 1.42 1.80 2.19 6 bar g 3.81 4.39 4.83 5.21 5.70
7 bar g 0.72 1.22 1.66 2.10 2.56 7 bar g 4.44 5.12 5.64 6.08 6.65
8 bar g 0.82 1.39 1.90 2.40 2.92 8 bar g 5.08 5.86 6.44 6.95 7.60
9 bar g 0.93 1.61 2.19 2.77 3.39 9 bar g 5.86 6.74 7.46 8.04 8.82
10 bar g 1.02 1.74 2.37 3.00 3.65 10 bar g 6.45 7.32 8.06 8.69 9.50
11 bar g 1.12 1.91 2.62 3.33 4.07 11 bar g 7.41 8.42 9.16 9.98 10.6
12 bar g 1.22 2.09 2.87 3.66 4.48 12 bar g 8.05 9.18 10.0 11.0 11.7
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100%. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
126
www.parker.com/gsfe
HiFluxx DT604
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 1.05 1.55 2.32 3.06 3.75 4.49 4 bar g 8.21 8.68 9.51 10.4 11.2 12.1
5 bar g 1.32 1.94 2.90 3.83 4.69 5.62 5 bar g 10.3 10.8 11.9 13.0 14.1 15.2
6 bar g 1.62 2.41 3.64 4.82 6.02 7.20 6 bar g 12.5 13.5 14.9 16.4 17.4 18.7
7 bar g 1.89 2.81 4.25 5.62 7.02 8.40 7 bar g 14.6 15.8 17.4 19.1 20.4 21.8
8 bar g 2.16 3.22 4.85 6.42 8.02 9.60 8 bar g 16.7 18.0 19.9 21.8 23.3 25.0
9 bar g 2.41 3.60 5.54 7.23 8.97 11.1 9 bar g 19.3 20.5 22.7 24.6 26.9 28.8
10 bar g 2.71 4.02 6.07 8.03 10.0 12.0 10 bar g 21.6 22.9 24.9 27.3 30.1 31.2
11 bar g 2.89 4.31 6.62 8.80 10.9 13.2 11 bar g 24.6 26.3 28.5 30.8 33.8 35.6
12 bar g 3.07 4.60 7.17 9.58 11.8 14.3 12 bar g 26.1 28.1 30.8 33.5 36.5 38.7
Maximum pressure drop <0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9%), Argon (0.9%), CO2 (0.03%), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
127
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx TT604
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 1.05 1.55 2.32 3.06 3.75 4.49 4 bar g 8.21 8.68 9.51 10.4 11.2 12.1
5 bar g 1.32 1.94 2.90 3.83 4.69 5.62 5 bar g 10.3 10.8 11.9 13.0 14.1 15.2
6 bar g 1.62 2.41 3.64 4.82 6.02 7.20 6 bar g 12.5 13.5 14.9 16.4 17.4 18.7
7 bar g 1.89 2.81 4.25 5.62 7.02 8.40 7 bar g 14.6 15.8 17.4 19.1 20.4 21.8
8 bar g 2.16 3.22 4.85 6.42 8.02 9.60 8 bar g 16.7 18.0 19.9 21.8 23.3 25.0
9 bar g 2.41 3.60 5.54 7.23 8.97 11.1 9 bar g 19.3 20.5 22.7 24.6 26.9 28.8
10 bar g 2.71 4.02 6.07 8.03 10.0 12.0 10 bar g 21.6 22.9 24.9 27.3 30.1 31.2
11 bar g 2.89 4.31 6.62 8.80 10.9 13.2 11 bar g 24.6 26.3 28.5 30.8 33.8 35.6
12 bar g 3.07 4.60 7.17 9.58 11.8 14.3 12 bar g 26.1 28.1 30.8 33.5 36.5 38.7
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
128
www.parker.com/gsfe
HiFluxx ST606
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 0.77 1.25 1.71 2.13 2.63 4 bar g 4.85 5.37 5.99 6.39 6.83
5 bar g 0.96 1.56 2.14 2.66 3.28 5 bar g 6.07 6.72 7.49 7.99 8.54
6 bar g 1.20 1.98 2.70 3.41 4.19 6 bar g 7.45 8.52 9.44 10.24 10.9
7 bar g 1.40 2.31 3.15 3.98 4.89 7 bar g 8.69 9.94 11.0 11.9 12.7
8 bar g 1.60 2.64 3.60 4.55 5.59 8 bar g 9.93 11.4 12.6 13.6 14.5
9 bar g 1.80 3.00 4.08 5.17 6.41 9 bar g 11.3 12.9 14.3 15.5 16.7
10 bar g 2.00 3.30 4.49 5.69 6.99 10 bar g 12.6 14.2 15.7 17.1 18.2
11 bar g 2.10 3.56 4.87 6.18 7.61 11 bar g 14.5 16.0 17.5 19.2 20.5
12 bar g 2.20 3.82 5.24 6.68 8.23 12 bar g 15.2 17.2 18.9 20.7 22.2
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
129
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx TT606
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 1.90 2.74 4.12 5.40 6.70 8.07 4 bar g 15.0 15.9 17.7 18.9 20.1 21.8
5 bar g 2.38 3.42 5.15 6.75 8.38 10.1 5 bar g 18.8 19.9 22.1 23.6 25.1 27.2
6 bar g 2.93 4.34 6.53 8.64 10.6 12.8 6 bar g 22.9 24.7 26.8 29.4 31.9 33.4
7 bar g 3.42 5.06 7.62 10.1 12.4 15.0 7 bar g 26.7 28.8 31.2 34.3 37.3 39.0
8 bar g 3.91 5.78 8.71 11.5 14.2 17.1 8 bar g 30.5 33.0 35.7 39.2 42.6 44.5
9 bar g 4.48 6.63 10.1 13.3 16.4 19.5 9 bar g 35.0 37.8 41.2 45.1 49.3 52.6
10 bar g 4.89 7.23 10.9 14.4 17.7 21.4 10 bar g 38.2 41.2 44.6 49.0 53.2 57.8
11 bar g 5.27 7.88 12.0 15.8 19.7 23.8 11 bar g 44.8 47.3 51.6 55.4 61.0 64.3
12 bar g 5.65 8.54 13.1 17.2 21.6 26.2 12 bar g 48.0 51.2 56.5 60.3 66.9 70.7
Maximum pressure drop <0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
130
www.parker.com/gsfe
HiFluxx ST608
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 1.34 2.25 3.07 3.87 4.82 4 bar g 9.08 10.1 11.1 12.0 13.0
5 bar g 1.67 2.81 3.84 4.84 6.02 5 bar g 11.4 12.7 13.8 15.0 16.3
6 bar g 2.14 3.72 4.99 6.48 7.91 6 bar g 14.1 16.0 17.5 19.5 20.6
7 bar g 2.49 4.34 5.82 7.56 9.23 7 bar g 16.5 18.7 20.4 22.7 24.0
8 bar g 2.85 4.96 6.65 8.65 10.6 8 bar g 18.8 21.3 23.3 25.9 27.4
9 bar g 3.36 5.81 7.85 10.0 12.2 9 bar g 21.8 25.0 27.5 30.0 31.8
10 bar g 3.56 6.21 8.32 10.8 13.2 10 bar g 23.2 26.7 29.1 32.4 34.3
11 bar g 4.01 6.96 9.46 12.2 14.9 11 bar g 27.7 31.3 34.1 36.5 40.2
12 bar g 4.46 7.71 10.6 13.5 16.6 12 bar g 30.8 34.7 38.2 40.6 44.9
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Weight 5.3 kg
Particles filtered at 0.01 µm cut off
Connection inlet / outlet G3/4 female
Relative humidity <100% (non condensing)
Vent G1 female
Dimensional drawing Refer to K3.1.346
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
131
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx ST6010
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 2.21 3.61 4.92 6.28 7.76 4 bar g 14.4 16.3 17.7 19.5 21.0
5 bar g 2.76 4.52 6.15 7.85 9.70 5 bar g 17.9 20.3 22.1 24.3 26.2
6 bar g 3.39 5.92 8.02 10.2 12.8 6 bar g 22.4 25.4 28.1 30.7 33.3
7 bar g 3.96 6.90 9.35 12.0 14.9 7 bar g 26 .1 29.7 32.7 35.9 38.8
8 bar g 4.52 7.89 10.7 13.7 17.1 8 bar g 29.9 33.9 37.4 41.0 44.4
9 bar g 5.39 9.01 12.3 15.7 19.2 9 bar g 35.1 39.6 43.0 47.0 51.9
10 bar g 5.66 9.86 13.4 17.1 21.3 10 bar g 36.8 43.4 46.8 51.2 57.6
11 bar g 6.24 10.8 14.8 18.9 23.6 11 bar g 43.7 49.7 54.7 58.7 63.6
12 bar g 6.83 11.7 16.2 20.8 25.8 12 bar g 47.8 54.0 60.0 64.5 69.6
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
132
www.parker.com/gsfe
HiFluxx ST1506
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr 2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 1.06 1.45 2.29 3.17 4.05 5.02 4 bar g 8.98 9.15 9.84 11.1 12.1 13.0
5 bar g 1.56 2.15 3.38 4.68 5.98 7.41 5 bar g 13.3 13.5 14.5 16.4 17.9 19.3
6 bar g 2.04 2.81 4.42 6.12 7.82 9.69 6 bar g 17.3 17.7 19.0 21.4 23.5 25.2
7 bar g 2.40 3.30 5.20 7.20 9.20 11.4 7 bar g 20.4 20.8 22.4 25.2 27.6 29.6
8 bar g 2.88 3.96 6.24 8.64 11.0 13.7 8 bar g 24.5 24.9 26.8 30.2 33.1 35.6
9 bar g 3.36 4.62 7.28 10.1 12.9 16.0 9 bar g 28.6 29.1 31.3 35.3 38.6 41.5
10 bar g 3.84 5.28 8.32 11.5 14.7 18.2 10 bar g 32.6 33.3 35.8 40.3 44.2 47.4
11 bar g 4.32 5.94 9.36 13.0 16.6 20.5 11 bar g 36.7 37.4 40.2 45.4 49.7 53.4
12 bar g 4.80 6.60 10.4 14.4 18.4 22.8 12 bar g 40.8 41.6 44.7 50.4 55.2 59.3
13 bar g 5.04 6.93 10.9 15.1 19.3 23.9 13 bar g 42.8 43.7 47.0 52.9 58.0 62.2
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
133
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx DT1506-8
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 2.31 3.63 6.25 8.58 10.9 13.2 4 bar g 19.6 22.9 26.9 30.0 32.6 34.3
5 bar g 3.41 5.36 9.23 12.7 16.1 19.5 5 bar g 29.0 33.8 39.7 44.4 48.2 50.7
6 bar g 4.46 7.01 12.1 16.6 21.0 25.5 6 bar g 37.9 44.2 51.9 58.0 63.0 66.3
7 bar g 5.25 8.25 14.2 19.5 24.7 30.0 7 bar g 44.6 52.0 61.1 68.3 74.1 78.0
8 bar g 6.30 9.90 17.0 23.4 29.6 36.0 8 bar g 53.6 62.4 73.3 81.9 88.9 93.6
9 bar g 7.35 11.6 19.9 27.3 34.6 42.0 9 bar g 62.5 72.8 85.5 95.6 104 109
10 bar g 8.40 13.2 22.7 31.2 39.5 48.0 10 bar g 71.4 83.2 97.7 109 119 125
11 bar g 9.45 14.9 25.6 35.1 44.5 54.0 11 bar g 80.3 93.6 110 123 133 140
12 bar g 10.5 16.5 28.4 39.0 49.4 60.0 12 bar g 89.3 104 122 137 148 156
13 bar g 11.0 17.3 29.8 41.0 51.9 63.0 13 bar g 93.7 109 128 143 156 164
Maximum pressure drop <0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
134
www.parker.com/gsfe
HiFluxx ST1508
ØD
Material
Feed-air Conditions
Housing Aluminum
Maximum operating pressure 13.0 bar g
Min. / Max. operating temperature +2°C / +50°C
Maximum oil vapour content <0.01 mg/m3
Services on Request
Particles filtered at 0.01 µm cut off Material certificates EN10204-3.1 on housing material
(for Stainless Steel only)
Relative humidity <100% (non condensing)
3D model CAD STEP file
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
135
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx DT1508
H D
Performance data
Performance
Performance data is data
based on 20°C feed-air temperature and 1013 mbar ambient pressure
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
136
www.parker.com/gsfe
HiFluxx DT1508SS
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr 2 Feed-air consumption at minimum nitrogen flow rate in m3/hr2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 3.08 4.84 8.36 11.4 14.5 17.6 4 bar g 26.2 30.5 35.9 40.0 43.6 45.8
5 bar g 4.55 7.15 12.4 16.9 21.5 26.0 5 bar g 38.7 45.0 53.1 59.2 64.4 67.6
6 bar g 5.95 9.35 16.2 22.1 28.1 34.0 6 bar g 50.6 58.9 69.4 77.4 84.2 88.4
7 bar g 7.00 11.0 19.0 26.0 33.0 40.0 7 bar g 59.5 69.3 81.7 91.0 99.0 104
8 bar g 8.40 13.2 22.8 31.2 39.6 48.0 8 bar g 71.4 83.2 98.0 109 119 125
9 bar g 9.80 15.4 26.6 36.4 46.2 56.0 9 bar g 83.3 97.0 114 127 139 146
10 bar g 11.2 17.6 30.4 41.6 52.8 64.0 10 bar g 95.2 111 131 146 158 166
11 bar g 12.6 19.8 34.2 46.8 59.4 72.0 11 bar g 107 125 147 164 178 187
12 bar g 14.0 22.0 38.0 52.0 66.0 80.0 12 bar g 119 139 163 182 198 208
13 bar g 14.7 23.1 39.9 54.6 69.3 84.0 13 bar g 125 146 172 191 208 218
Maximum pressure drop <0.8 bar.
Maximum nitrogen flow rate = minimum flow rate + 10%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
137
Industrial Nitrogen Gas Generation - Membrane Modules
HiFluxx ST15020-1
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Typical nitrogen flow rate in m3/hr2 Feed-air consumption at typical nitrogen flow rate in m3/hr2
Purity %1 Purity %
99 98 97 96 95 99 98 97 96 95
4 bar g 24.0 39.0 53.0 71.0 89.0 4 bar g 161 175 191 220 239
5 bar g 35.0 58.0 78.0 105 131 5 bar g 238 259 283 324 353
6 bar g 46.0 75.0 103 137 171 6 bar g 289 324 359 411 445
7 bar g 54.0 89.0 121 161 201 7 bar g 340 381 423 483 523
8 bar g 59.0 97.0 133 177 221 8 bar g 374 419 465 531 576
Maximum pressure drop <0.3 bar.
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by subtracting
the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be born in mind that the
value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20 °C
Above tables reflect nominal flow rates. The nitrogen output of each
individual module can vary +/- 15%. For selection purposes, calculation Example:
should be done based on nominal conditions without taking the variation Your project requires 1515 Nm3/hr nitrogen at 8 bar g inlet pressure,
into account. When ordering modules, it is necessary that the total modules 95% purity and 20°C inlet temperature. You will need 7 modules.
needed for each individual project are clearly mentioned per order-line on Parker will ensure a minimum total product flow of 1515 Nm3/hr.
the order-intake-form. Parker will assure that the total output flow rate However, individual module performance can still vary +/-15%. The
(sum of the individual selected membranes flow rates) will be minimum the compressor should be selected on a total air consumption of 7 x 576 =
total nominal flow rate. The compressor selection can be done on the total 4032 Nm3/hr.
calculated nominal flow rate without taking any variation into account.
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
138
www.parker.com/gsfe
HiFluxx ST1508SS
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum nitrogen flow rate in m3/hr2 Feed-air consumption at minimum nitrogen flow rate in m3/hr2
Purity %1 Purity %
99.5 99 98 97 96 95 99.5 99 98 97 96 95
4 bar g 2.07 2.95 4.84 6.60 8.8 11.0 4 bar g 17.6 18.6 20.8 23.1 26.4 28.6
5 bar g 3.06 4.36 7.15 9.75 13.0 16.3 5 bar g 26.0 27.4 30.7 34.1 39.0 42.3
6 bar g 4.00 5.70 9.35 12.8 17.0 21.3 6 bar g 34.0 35.9 40.2 44.6 51.0 55.3
7 bar g 4.70 6.70 11.0 15.0 20.0 25.0 7 bar g 40.0 42.2 47.3 52.5 60.0 65.0
8 bar g 5.17 7.37 12.1 16.5 22.0 27.5 8 bar g 43.9 46.4 52.0 57.8 66.0 71.5
9 bar g 6.11 8.71 14.3 19.5 26.0 32.5 9 bar g 51.9 54.9 61.5 68.3 78.0 84.5
10 bar g 6.58 9.38 15.4 21.0 28.0 35.0 10 bar g 55.9 59.1 66.2 73.5 84.0 91.0
11 bar g 7.52 10.7 17.6 24.0 32.0 40.0 11 bar g 63.9 67.5 75.7 84.0 96.0 104
12 bar g 7.99 11.4 18.7 25.5 34.0 42.5 12 bar g 67.9 71.8 80.4 89.3 102.0 111
13 bar g 8.46 12.1 19.8 27.0 36.0 45.0 13 bar g 71.9 76.0 85.1 94.5 108.0 117
Maximum pressure drop <0.3 bar.
Maximum nitrogen flow rate = minimum flow rate + 30%
1. Parker membranes separate oxygen from pressurised air. The composition of the product is determined by measuring the residual oxygen content. The nitrogen content is calculated by
subtracting the residual oxygen content from 100 %. Air is composed of nitrogen (78.1%), oxygen (20.9 %), Argon (0.9 %), CO2 (0.03 %), and some trace inert gases. Therefore it should be
born in mind that the value that is normally called the nitrogen content actually is the inert gas content.
2. m3/hr refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
139
Industrial Nitrogen Gas Generation - Membrane Modules
EnOxy 304
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Minimum enriched oxygen flow rate in l/min 1 Feed-air consumption at minimum enriched oxygen flow rate in l/min 1
Purity % Purity %
28 30 32 34 36 38 40 28 30 32 34 36 38 40
4 bar g 16.9 17.3 17.7 18.1 18.4 18.8 - 4 bar g 24.5 28.4 33.4 41.3 54.2 77.1 -
5 bar g 21.5 22 22.5 23.0 23.5 24.0 24.5 5 bar g 31.2 35.5 41.1 49.5 61.7 80.6 139
6 bar g 26.3 26.9 27.5 28.1 28.7 29.3 29.9 6 bar g 38.1 43.3 50.2 58.1 72.8 92.2 138
7 bar g 31.1 31.9 32.6 33.3 34.0 34.7 35.4 7 bar g 45.1 51.2 59.5 68.8 83.1 104 149
8 bar g 36.1 37.0 37.8 38.6 39.4 40.2 41.1 8 bar g 52.4 59.4 69.0 79.9 96.5 120 166
9 bar g 41.3 42.2 43.1 44.1 45.0 45.9 46.9 9 bar g 59.8 67.8 78.8 91.2 111 137 187
10 bar g 46.5 47.5 48.6 49.7 50.7 51.8 52.8 10 bar g 67.4 76.6 88.8 103 125 158 219
11 bar g 51.9 53 54.2 55.4 56.6 57.8 58.9 11 bar g 75.7 85.7 99.6 116 143 182 261
12 bar g 57.3 58.6 59.9 61.3 62.6 63.9 65.2 12 bar g 83.7 95.0 110 129 160 208 310
Enriched oxygen flow exits at atmospheric pressure
Maximum pressure drop over nitrogen enriched flow <0.3 bar.
Maximum enriched oxygen flow rate = minimum flow rate + 30%
1. l/min refers to conditions at 1013 mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
140
www.parker.com/gsfe
EnOxy 604
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
1
Oxygen Minimum enriched oxygen flow rate in l/min 1) Oxygen Feed-air consumption at minimum enriched oxygen flow rate in l/min
purity % 28 30 32 34 36 38 40 purity % 28 30 32 34 36 38 40
4 bar g 35.7 36.6 37.4 38.2 39.0 39.8 - 4 bar g 49.3 57.2 67.3 83.2 109 155 -
5 bar g 45.5 46.6 47.6 48.6 49.7 50.7 51.7 5 bar g 62.8 71.6 82.8 99.7 124 162 279
6 bar g 55.6 56.8 58.1 59.3 60.6 61.9 63.1 6 bar g 76.7 87.1 101 117 147 186 278
7 bar g 65.9 67.4 68.9 70.4 71.8 73.3 74.8 7 bar g 90.9 103 120 139 167 209 299
8 bar g 76.4 78.1 79.9 81.6 83.4 85.1 86.8 8 bar g 105 120 139 161 194 243 334
9 bar g 87.2 89.2 91.2 93.2 95.2 97.2 99.1 9 bar g 120 136 159 184 223 277 377
10 bar g 98.3 101 103 105 107 109 112 10 bar g 136 154 179 208 252 318 441
11 bar g 110 112 115 117 120 122 125 11 bar g 152 172 201 233 287 366 525
12 bar g 121 124 127 130 132 135 138 12 bar g 169 191 222 259 321 419 624
Enriched oxygen flow exits at atmospheric pressure
Maximum pressure drop over nitrogen enriched flow <0.3 bar.
Maximum enriched oxygen flow rate = minimum flow rate + 30%
1. l/min refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
141
Industrial Nitrogen Gas Generation - Membrane Modules
EnOxy 606
H D
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Oxygen Minimum enriched oxygen flow rate in l/min 1) Oxygen Feed-air consumption at minimum enriched oxygen flow rate in l/min 1)
purity % 28 30 32 34 36 38 40 purity % 28 30 32 34 36 38 40
4 bar g 69.2 70.8 72.3 74.0 75.5 77.2 - 4 bar g 95.6 111 130 161 212 301 -
5 bar g 88.2 90.2 92.2 94.2 96.2 98.2 100 5 bar g 122 139 160 193 241 314 541
6 bar g 108 110 113 115 118 120 122 6 bar g 149 169 196 227 284 360 538
7 bar g 128 131 133 136 139 142 145 7 bar g 176 200 232 269 324 405 580
8 bar g 148 151 155 158 162 165 168 8 bar g 204 232 269 312 376 470 648
9 bar g 168 173 177 180 185 188 192 9 bar g 233 264 307 356 431 536 730
10 bar g 190 195 198 203 208 212 217 10 bar g 263 299 347 403 488 615 855
11 bar g 212 217 222 227 232 237 242 11 bar g 295 334 389 452 556 710 1018
12 bar g 235 240 245 252 257 262 267 12 bar g 327 371 430 502 623 811 1208
Enriched oxygen flow exits at atmospheric pressure
Maximum pressure drop over nitrogen enriched flow <0.3 bar.
Maximum enriched oxygen flow rate = minimum flow rate + 30%
1. l/min refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
142
www.parker.com/gsfe
EnOxy 608
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Oxygen Minimum enriched oxygen flow rate in l/min 1) Oxygen Feed-air consumption at minimum enriched oxygen flow rate in l/min 1)
purity % 28 30 32 34 36 38 40 purity % 28 30 32 34 36 38 40
4 bar g 128 131 134 137 140 143 - 4 bar g 177 206 242 299 392 557 -
5 bar g 163 167 170 174 178 181 185 5 bar g 225 256 296 357 444 580 998
6 bar g 199 203 207 212 216 221 225 6 bar g 274 311 361 417 523 662 991
7 bar g 235 240 246 251 256 261 267 7 bar g 324 368 427 494 597 745 1066
8 bar g 273 279 285 291 297 303 309 8 bar g 376 426 495 573 692 864 1190
9 bar g 311 318 325 332 339 346 353 9 bar g 429 487 565 654 793 985 1340
10 bar g 351 358 366 374 382 390 397 10 bar g 484 550 637 741 897 1130 1569
11 bar g 391 400 408 417 426 435 443 11 bar g 543 615 715 830 1022 1304 1869
12 bar g 432 442 452 461 471 481 490 12 bar g 601 682 791 923 1145 1490 2219
Enriched oxygen flow exits at atmospheric pressure
Maximum pressure drop over nitrogen enriched flow <0.3 bar.
Maximum enriched oxygen flow rate = minimum flow rate + 30%
1. l/min refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
143
Industrial Nitrogen Gas Generation - Membrane Modules
EnOxy 6010
ØD
Performance data
Performance data is based on 20°C feed-air temperature and 1013 mbar ambient pressure
Oxygen Minimum enriched oxygen flow rate in l/min 1) Oxygen Feed-air consumption at minimum enriched oxygen flow rate in l/min 1)
purity % 28 30 32 34 36 38 40 purity % 28 30 32 34 36 38 40
4 bar g 250 256 262 268 274 280 - 4 bar g 345 401 472 585 768 1093 -
5 bar g 318 325 333 341 348 356 364 5 bar g 438 500 579 698 871 1139 1964
6 bar g 387 396 406 415 425 434 443 6 bar g 534 608 706 818 1027 1302 1950
7 bar g 458 470 481 492 503 514 525 7 bar g 633 718 836 969 1172 1465 2101
8 bar g 532 545 558 571 584 596 609 8 bar g 734 833 970 1124 1360 1700 2346
9 bar g 607 622 637 652 666 681 696 9 bar g 838 952 1108 1284 1559 1941 2644
10 bar g 685 701 718 735 751 768 784 10 bar g 945 1076 1249 1455 1765 2227 3097
11 bar g 764 783 801 820 838 857 875 11 bar g 1062 1204 1402 1632 2012 2571 3691
12 bar g 846 866 887 907 928 948 969 12 bar g 1176 1336 1552 1814 2254 2939 4385
Enriched oxygen flow exits at atmospheric pressure
Maximum pressure drop over nitrogen enriched flow <0.3 bar
Maximum enriched oxygen flow rate = minimum flow rate + 30%
1) l/min refers to conditions at 1013mbar(a) and 20°C
Note
Parker membrane systems produce both nitrogen and oxygen enriched air. Nitrogen enriched air can cause suffocation and oxygen enriched air causes
increased fire hazards. The oxygen enriched air is available at ambient pressure and pressure build-up of enriched oxygen at the outlet must be
prevented, otherwise a serious (reversible) decrease in performance will result. The nitrogen enriched air produced should be treated as pressurised air.
144
www.parker.com/gsfe
Compressor Filtration
Due to varying nitrogen or oxygen enriched-air demands, the feed-air To filter the feed-air to the specified quality the following filters are
requirements will also vary. Parker advises to use a variable speed needed:
screw compressor to get the highest efficiency and best working
conditions for the compressor. At pressures of 7 to 8 barg, standard Coarse coalescing filter
industrial screw compressors have their highest efficiency which is A coarse coalescing filter for 1 Micron particles.
also the most optimal pressure with the lowest energy use for the
This filter is normally located before the refrigerant dryer
Parker membranes modules.
or the fine coalescing filter.
Air receiver Fine coalescing filter
In case a variable speed screw compressor is used, it is not necessary A fine coalescing filter for 0.01 Micron particles. This filter is normally
to use an air receiver. When a non-variable speed compressor is used located after the refrigerant dryer or the coarse coalescing filter.
with an air receiver, the receiver must be
of such a size that the compressor will not switch on and off Carbon absorber, bed-type
at a high frequency as this will cause increased oil carryover. An activated carbon absorber, bed-type filled with carbon granulates.
Filters with an active carbon element are not sufficient for the
Water separator protection of nitrogen membrane modules.
A water separator is recommended when it is unsure whether liquid
water can be carried over. The downstream coalescing filters are not Dust filter
designed to remove bulk water. In case that pipework between air Because a carbon bed can cause dust, particulate filtration is needed.
receiver - dryer is short and pipework is indoors a water separator can Dependent of the dust carry-over of the bed, one fine filter, or coarse
be void. and fine filter are needed, whichever is appropriate to meet the
requirements.
Refrigerant dryer General
A refrigerant dryer is sufficient to lower the dew point to an acceptable All filters should be sized correctly for the application.
level. When a nitrogen or oxygen enriched-air system is located in
an environment where the temperature cannot drop below 8°C a Maintenance and filter element change must be carried out following
refrigerant dryer that creates a dew point of 3°C is sufficient. Should the applicable instructions and in line with the application.
the feed-air temperature drop below 8°C, another drying method
is required, for example an adsorption dryer. The refrigerant dryer Depending on the system requirements Parker
should be sized correctly and should be equipped with sufficient has a wide range of compressed air pre-filtration
condensate removal. products to select from.
145
Membrane Temperature Correction Factors www.parker.com/gsfe
Hereafter are the tables with correction factors for temperatures differing from 20ºC for the HiFluxx/Smartfluxx and Enoxy membrane
modules.
HiFluxx
Table 1 Table 2
Nitrogen flow rate correction factor for HiFluxx Feed-Air consumption correction factor for
Temperature at various product concentrations1) Temperature HiFluxx at various product concentrations1)
99.5% 99% 98% 97% 96% 95% 99.5% 99% 98% 97% 96% 95%
5ºC (41°F) 0.9 0.9 0.9 0.9 0.9 0.9 5ºC (41°F) 0.8 0.8 0.8 0.8 0.8 0.8
10ºC (50°F) 0.9 0.9 0.9 0.9 0.9 0.9 10ºC (50°F) 0.9 0.9 0.9 0.9 0.9 0.9
30°C (86°F) 1.0 1.0 1.0 1.0 1.0 1.0 30°C (86°F) 1.1 1.1 1.1 1.1 1.1 1.1
40ºC (104°F) 0.6 0.8 1.0 1.0 1.1 1.1 40ºC (104°F) 1.2 1.2 1.2 1.2 1.2 1.2
50ºC (122°F) 0.6 0.8 1.0 1.1 1.1 1.2 50ºC (122°F) 1.3 1.3 1.3 1.3 1.3 1.3
Example
Sizing conditions
Inlet pressure 7 barg
Nitrogen purity 97%
Feed-air temperature 50ºC
N2 correction factor 1.1 (table 1)
Feed-air correction factor 1.3 (table 2) Corrected Nitrogen Flow Calculation at 50ºC and 97%
Module HiFluxx ST1508 Corrected nitrogen flow: 15 m3/hr x 1.1 = 16.5 m3/hr
N2 flow rate HiFluxx ST1508 15 m3/hr (at 20ºC)
Corrected Feed-Air Calculation at 50ºC and 97%
Feed-air consumption HiFluxx ST1508 52.5 m3/hr (at 20ºC) Corrected feed-air flow: 52.5 m3/hr x 1.3 = 68.3 m3/hr
1)
These numbers are indicative and may vary by +/- 0.1
SmartFluxx
Table 1 Table 2
Nitrogen flow rate correction factor for SmartFluxx (SA) Feed-Air consumption correction factor for SmartFluxx
at various product concentrations1) (SA) at various product concentrations1)
Temperature Temperature
99.5% 99% 98% 97% 96% 95% 99.5% 99% 98% 97% 96% 95%
5°C (41°F) - - 0.90 0.90 0.90 0.90 5°C (41°F) - - 0.90 0.90 0.90 0.90
10°C (50°F) - - 0.95 0.95 0.95 0.95 10°C (50°F) - - 0.95 0.95 0.95 0.95
20°C (68°F) 1.00 1.00 1.00 1.00 1.00 1.00 20°C (68°F) 1.00 1.00 1.00 1.00 1.00 1.00
30°C (86°F) 1.00 1.03 1.05 1.05 1.05 1.05 30°C (86°F) 1.10 1.10 1.10 1.10 1.10 1.10
40°C (104°F) 1.00 1.05 1.10 1.10 1.10 1.10 40°C (104°F) 1.25 1.20 1.15 1.15 1.10 1.10
50°C (122°F) 1.00 1.05 1.10 1.10 1.15 1.15 50°C (122°F) 1.35 1.30 1.25 1.20 1.15 1.15
60°C (140°F) 1.10 1.15 1.20 1.20 1.25 1.20 60°C (140°F) 1.60 1.60 1.55 1.55 1.50 1.50
1)
These numbers are indicative and may vary by +/- 0.1
146
www.parker.com/gsfe
EnOxy
Table 1 Table 2
Oxygen flow rate correction factor for Feed-Air consumption correction factor for
Temperature EnOxy at various product concentrations1) Temperature EnOxy at various product concentrations1)
28% 30% 32% 34% 36% 38% 40% 28% 30% 32% 34% 36% 38% 40%
5ºC (41°F) 0.76 0.76 0.76 0.76 0.76 0.76 0.76 5ºC (41°F) 0.76 0.76 0.76 0.76 0.76 0.76 0.76
10ºC (50°F) 0.84 0.84 0.84 0.84 0.84 0.84 0.84 10ºC (50°F) 0.84 0.84 0.84 0.84 0.84 0.84 0.84
15ºC (59°F) 0.91 0.91 0.91 0.91 0.91 0.91 0.91 15ºC (59°F) 0.91 0.91 0.91 0.91 0.91 0.91 0.91
25ºC (77°F) 1.09 1.09 1.09 1.09 1.09 1.09 1.09 25ºC (77°F) 1.09 1.09 1.09 1.09 1.09 1.09 1.09
30°C (86°F) 1.19 1.19 1.19 1.19 1.19 1.19 1.19 30°C (86°F) 1.19 1.19 1.19 1.19 1.19 1.19 1.19
35ºC (95°F) 1.30 1.30 1.30 1.30 1.30 1.30 1.30 35ºC (95°F) 1.30 1.30 1.30 1.30 1.30 1.30 1.30
40ºC (104°F) 1.42 1.42 1.42 1.42 1.42 1.42 * 40ºC (104°F) 1.42 1.42 1.42 1.42 1.42 1.42 *
45ºC (113°F) 1.54 1.54 1.54 1.54 1.54 1.54 * 45ºC (113°F) 1.54 1.54 1.54 1.54 1.54 1.54 *
50ºC (122°F) 1.68 1.68 1.68 1.68 1.68 * * 50ºC (122°F) 1.68 1.68 1.68 1.68 1.68 * *
1)
These numbers are indicative
*) No enriched oxygen can be generated at this temperature / oxygen% combination
Example
Sizing conditions
Inlet pressure 7 bargg
Nitrogen purity 34%
Feed-air temperature 30ºC
N2 correction factor 1.19 (table 1)
Feed-air correction factor 1.25 (table 2) Corrected Nitrogen Flow Calculation at 30ºC and 34%
Module EnOxy 608 Corrected oxygen flow: 251 l/hr x 1.19 = 298.7 l/hr
N2 flow rate EnOxy608 251 l/hr (at 20ºC)
Corrected Feed-Air Calculation at 30ºC and 34%
Feed-air consumption EnOxy608 494 l/hr (at 20ºC) Corrected feed-air flow: 494 l/hr x 1.25 = 617.5 l /hr
147
Carbon Dioxide Quality Incident Protection
Liquid CO2
storage tank
CO2 delivery
truck
148
www.parker.com/gsfe
The ISBT is a highly respected body which is dedicated to the promotion, development and dissemination of knowledge relating to the art
and science of beverage technology.
The quality guidelines and analytical procedure bibliography has been developed by the ISBT to provide guidance for manufacturers of
carbonated beverages and suppliers of carbon dioxide to the carbonated beverage industries about key characteristics for the quality and
purity of carbon dioxide when used as a direct food additive in beverages.
The following table lists the voluntary quality standards taken from the document with relation to CO2 quality.
Nitric Oxide / Nitrogen Dioxide: 2.5 ppm v/v max. (each) Regulatory
Total Volatile Hydrocarbons: 50 ppm v/v max. including 20 ppm v/v max.
Sensory
(as Methane) as total non-methane hydrocarbons
149
Carbon Dioxide Quality Incident Protection
Correction Factors
bar g 3 4 5 6 7 8 9 10 11 12 13
Inlet Pressure
psi g 44 58 73 87 102 116 130 145 160 174 189
Correction factor 0.19 0.23 0.28 0.33 0.38 0.42 0.47 0.52 0.57 0.61 0.66
bar g 14 15 16 17 18 19 20 21 22 23 24
Inlet Pressure
psi g 203 218 232 247 261 275 290 304 319 333 348
Correction factor 0.71 0.76 0.80 0.85 0.90 0.95 1 1 1 1 1
Operation
Stage 1
0.01 micron particle filtration
Removal of non-volatile organic residue (NVOR) and
other contaminants down to 0.01 ppm
Stage 2
Removal of water vapour and partial removal of
hydrocarbons
Stage 3
Primary removal of aromatic hydrocarbons (Benzene,
Toluene etc and Acetaldehyde)
Stage 4
Removal of sulphur compounds (COS, H2S, DMS etc)
Stage 5
0.01 micron particle filtration
Stage 6*
Point of use VBACE sterile gas membrane. Hi Flow
Tetpor II
150
www.parker.com/gsfe
H H
W
D W
D
PCO2-1600 1060.7 41.8 801 31.5 450 17.7 680 27 128 282
PCO2-2400 1060.7 41.8 970 39.4 450 17.7 680 27 172 379
PCO2-3200 1060.7 41.8 1139 44.8 450 17.7 680 27 217 478
PCO2-4000 1060.7 41.8 1308 51.5 450 17.7 680 27 260 573
PCO2-4800 1060.7 41.8 1477 58.1 450 17.7 680 27 304 670
*All systems are supplied as NPT with stainless steel adapters 'NPT to BSP' as standard.
** Clearance required for the removal and servicing of cartridges.
151
Bioenergy
The standard biogas dehumidification package includes water connections between Hyperchill and Hypercool, water isolating valves, a
water expansion tank and a counter flange kit with gaskets for the system's connection to the customer's piping.
152
www.parker.com/gsfe
SKD B C D
SKD-R B C D
153
Bioenergy
BioEnergy Products
For information relating to Hyperchill BioEnergy water chillers please refer to page 96 of this catalogue.
Hyperfilter BioEnergy
Area of Application
Standard Filter Biogas, Landfill Gas and Natural Gas
Max. Operating Pressure 0.5 bar g (7.25 psi g)
Operating Temperature -10°C (14°F) up to 100°C (212°F)
Performance Data
Removal Pollutants, foams, particulate and separation of residual moisture
Flow Direction From outside to inside
Particle Removal Size 5 µm / 20 µm
Filtration Efficiency 99.999%
Differential Pressure. Dry 2 mbar
Technical Data
Gas Flow* Connections Filter Elements
Model
L/S m3/min m3/h cfm In Out Quantity
FFB105 29 1.8 105 62 DN50 DN80 1
FFB265 74 4.4 265 156 DN80 DN125 1
FFB720 200 12.0 720 424 DN125 DN200 1
FFB1110 308 18.5 1110 653 DN200 DN300 1
FFB3180 695 41.7 2500 1472 DN300 DN450 1
*Nominal working conditions: gas inlet temperature 40°C (104°F), atmospheric pressure, 60%CH4, 40%CO2, pressure drop 3 mbar.
FFB Filters can work at higher gas flow rates with an increase in pressure drop (refer to Parker).
154
www.parker.com/gsfe
B C B D
B D
C
C
D
A C A
Hypersep BioEnergy
Technical Data / Weights & Dimensions
Dimensions
Gas Flow Connections Weight
Model A B C D
L/s m3/h m3/min cfm In Out mm ins mm ins mm ins mm ins kg lbs
CSB105 29 105 1.8 62 DN80 DN50 365.5 14.4 635.5 25.0 375.8 14.8 535.5 21.1 14 31
CSB265 74 265 4.4 156 DN125 DN80 460 18.1 1425 56.1 1038 40.9 1300 51.2 30 66
CSB720 200 720 12.0 424 DN200 DN125 570 22.4 1765 69.5 1293 50.9 1595 62.8 54 119
CSB1620 450 1620 27.0 954 DN300 DN200 638 25.1 1747.5 68.8 1156 45.5 1525 60.0 88 194
CSB3180 883 3180 53.0 1872 DN450 DN300 833 32.8 2113 83.2 1264 49.8 1805 71.1 153 337
Hypercool BioEnergy
Technical Data / Weights & Dimensions
Dimensions
Gas Flow Connections Weight
Model A B C
L/s m3/h m3/min cfm Gas Water mm ins mm ins mm ins kg lbs
WFB60 17 60 1.0 35 DN80 ¾" 1490 58.7 65.5 2.6 89 3.5 16 35
WFB105 29 105 1.8 62 DN80 ¾" 1490 58.7 65.5 2.6 89 3.5 19 42
WFB165 46 165 2.8 97 DN125 1" 1490 58.7 100.5 4.0 140 5.5 30 66
WFB265 74 265 4.4 156 DN125 1" 1490 58.7 100.5 4.0 140 5.5 38 84
WFB240 67 240 4.0 141 DN125 1" 1990 78.3 100.5 4.0 140 5.5 48 106
WFB360 100 360 6.0 212 DN200 1¼" 1990 78.3 120.5 4.7 219 8.6 85 187
WFB510 142 510 8.5 300 DN200 1¼" 1990 78.3 120.5 4.7 219 8.6 102 224
WFB720 200 720 12.0 424 DN200 1¼" 1990 78.3 120.5 4.7 219 8.6 124 273
WFB1110 308 1110 18.5 653 DN300 2" 1990 78.3 144.5 5.7 324 12.8 196 431
WFB1620 450 1620 27.0 954 DN300 2" 1990 78.3 144.5 5.7 324 12.8 252 554
WFB2380 661 2380 39.7 1401 DN450 2½" 1990 78.3 179.5 7.1 457 18.0 405 891
WFB3180 883 3180 53.0 1872 DN450 2½" 1990 78.3 179.5 7.1 457 18.0 490 1078
Performances refer to models operating with gas flow rate at FAD 20°C (68°F) / 1 barA.
Nominal working conditions: gas inlet conditions 40°C (104°F) saturated 60%CH4 , 40%CO2, water inlet temperature 1°C (34°F), gas outlet temperature 8°C
(46°F) for models WFB60, WFB105, WFB165, WFB265, 4°C (39°F) for all other models. pressure drop 1.2 kPa with separator.
Hyperdrain BioEnergy
Technical Data / Weights & Dimensions
Maximum Dimensions
Materials of Construction Gas Flow Conns. Weight
Model Pressure A B C
Housing Float Lever L/s m3/h m3/min cfm in out bar g psi g mm ins mm ins mm ins kg lbs
Polyamide/ Polyamide/
HDF220BE Aluminium 2 6.5 108 4 1" ½" 1 14.5 266 10.5 111 4.4 108 4.3 1.9 4
st. steel st. steel
155
Replacement Filter Elements and Maintenance Kits
AA025 P025AAX12 12
ACS025 P025ACSX12 12
AO030 P030AOX12 12
AA030 P030AAX12 12
ACS030 P030ACSX12 12
PCO2 MKI
Maintenance Kits
Product Type Model Filter Type Maintenance Kit
158
www.parker.com/gsfe
159
www.parker.com/gsfe