ITC-VA-6000 System Introduction
ITC-VA-6000 System Introduction
hting
linkage
WP
Monitor
Va titio
Pa
rie n
r
EN54
d
PA
Content
1 System Introduction 2 Function & Features 3 Product Overview
Curently, you may find the size of buildings are getting bigger and higher, and the entire region area is wider and wider. The voice alarm evacuation system,
using traditional analog signal transmission and monitoring technology, not only needs to solve signal attenuation problem during long distance
transmission, but also need to solve different space environment of the electric and magnetic harassment, and facing many problems, including the
construction cost, wiring, maintenance upgrade in the future, centralized control and monitoring of the system, data backup, line redundancy and so on...
So in order to solve the above problems, ITC VA-6000 system came into being.
System Overview
VA-6000 Series
Zone1
Charger VA-6000BC
Battery
CAT6 Paging MIC Fireman MIC Zone253
VA-6000RM VA-6000FM Digital Amplifier
Power Supply
Audio Cable
Telephone
Power Cable
Fire linkage Control PC
signal Digital Amplifier
Metallic Yarn Zone255
System Diagram
Volume Speaker
Control
Zone1
Zone248
Charger VA-6000BC
CAT6 Battery
……
Paging MIC Fireman MIC
VA-6000RM VA-6000FM Digital Amplifier
Audio Cable Power Supply
RVV Wire
8 Zone Amplifier VA-P8500S Zone254
Power Cable Telephone
Zone1
Solution
Class D amplifier
Controller host VA-6000MA Zone 4
Power ……
Partition
Zone 248
Nerwork cable
Charger VA-6000BC
Power Cable
Eight-zone amplifier VA-P8500S Zone 254
Only CAT-5 cable is needed between system devices, which can simultaneously transmit multiple high-quality digital audio signals
and control signals.
Integrating with voice alarm evacuation, remote paging and background music play functions into one system.
4. Flexible Zone Configuration
Support maximum 255 power partitions solution, 255 signal partitions solution or 255 power partitions by 32pcs VA-8500S +
(255-32=223) signal partitions by 28pcs VA-6000MS
VA-6000MS Changeover
5. 4 Independent messages
4 line in
The host support one key touch for emergency alarm and one key touch for reset, ensuring the system responses quicky
during emergency situation
12.Host Backup
The backup host can replace the master host automatically when it fails to work, which makes the system keep
working continually.
13. Amplifier Backup
When there is no task, amplifier will enter into sleeping mode automatically to save power, and wake up automatically
when there is a task
15.Remote Paging and Remote Control
The system can connect with 4 remote business/firemen microphones, and up to 32pcs touch screen microphones;
support remote program playing, zone control, one-key touch for reset and local programs inserting, etc.
16. Telephone Remote Announcement
VA-6000MA
17. Real-time State Display
The system equipment have plenty real-time state indicators,including power supply, working state, failure indicators, etc.
The users can check equipments' operation state directly and quickly.
18. Real-Time State Output
The system host is equipped with failure and working state output interface. The host send real-time operation states of the system,
by connecting with the third-party equipments, which is convenient to monitor the system remotely.
output
19. Two Volume Control Relay Modes
The relay modes of 3-wired volume control and 4-wired volume control enable the system flexibly applied in different
places to control the volume, and realize the override function.
20. 24V DC Power Supply
The entire system supports 24V power supply. When the AC power is cut off, the devices automatically check and switch to
the 24V backup power supply to ensure normal use of evacuation system.
Charger VA-6000BC
Battery
Supply power for all devices in the system with 24V DC which is stable
and reliable
Content CONTENT
Change over VA-6000MS Digital amplifier Charger VA-6000BC End of line detector Extension panel Fire alarm mic Paging mic
VA-6000T VA-6000EM VA-6000FM VA-6000RM
Management software
VA-6000ST
Controller VA-6000MA 8-zone amp VA-P8500S Recorder VA-6000RC
VA-6000/4240(including VA-6000MA、VA-P8500S、VA-6000RC)
Product Overview of EVAC System
Evacuation indicator
DC indicator
Fault indicator
Reset key
PTT indicator
Features
Fault output/working status
With 5 inch LCD touch operation display output/reset input
Support zone selection, zone management and group operation DC24V output
Line input
Short input Short output Mic input Line output
Support power partitions and signal partitions configuration
Support event trigger, timing trigger output
Integrated with 4 independent players
Support line redundant wiring
Support 4 remote microphone access
Support phone notification via event trigger
With full backup function
8 channels level signals or short circuirt contact
Up to 2000 log records
Network port Remote Mic port DC24V input
Built in 500W digital amplifier and 8 independent power Audio signal indicator Zone volume control Mic/Line volume
control
zones
Connect with an external backup amplifier to realize
main/standby switch function
Automatic real-time monitoring of the working status of
the speaker lines in each zone
Audio input
Speaker 100V input
8 programmable trigger input / output contacts
Provide DC 24V backup power input interface
Support line redundant wiring
DC24V power supply
Support 3 or 4 wired speaker circuit wiring Mic input
CAN port
Short input
Functions
Support 8 Main/1 Spare amplifier control
CAN port
Support 3/4 wired speaker circuit wiring
Local audio signal input/output Short-circuit the input/output
Support redundant wiring
Support online with linkage fire alarm control
8 programmable trigger input/output online interfaces
DC 24V standby power input interface
Automatic real-time monitoring of the working status of
each partition loop
100V signal input/output
DC24V
Backup power amplifier signal
output 100 v/audio input interface
Functions
1, 2 and 4 channels are optional, and the maximum
support is 4 * 500W
Overload and short circuit protection
Main and standby power amplifier switching
automatically and speaker line state detection
Auto checking working status of each channel and send
it to host VA-6000MA
Support 3-wired cabling
Recorder VA-6000RC
AC power indicator
DC power indicator
Recording status indicator
Functions SD card status indicator
Charging indicator
CAN port
DC24V input
DC24V ouput
Battery capacity selection
Temperature/voltage state input
Functions
Front Panel
Product Overview of EVAC System
Rear Panel
Power switch
Front Panel
Product Overview of EVAC System
Rear Panel
Volume adjustment
Monitor audio output
Power switch
DC24V input
Networking address
Extended line input
volume adjustment
Network master,
standby interface
Product Overview of EVAC System
Functions
Functions
IPS high-definition full-angle display; Graphical
touch operation; Clear version
System synchronization customize display of
zone/group name, with convenient and simple
operation.
Iconic zone status display, more vivid
expression and richer content
It can individually adjust the volume of each
zone and monitor current playlist content.
With one external audio connector on rear
panel and it can play audio source to any zone.
Support up to 32pcs VA-6000RT microphones
Product Overview of EVAC System
Functions
To be installed at the end of speaker line
Detect the working state of speaker line
No need external power supply
Applications for the EVAC System
1. Airport
2. Metro
3. School
4. Hotel
5. Train Station
6. Wharf
7. Shopping Mall
8. Chamber
9. Cinema
10. Stadium
11. Office Building
12. Residence community
......