PAMAS FastPatch 2 GO

Automatic microscope system


for quality control analysis
Advanced automated particle and fibre counting system

Complying with ISO 4407 – Standardised Applications:


measuring reports according to:
ƒƒ Dark fluids
ƒƒ SAE AS 4059 (B-F)
ƒƒ Two phase liquids
ƒƒ ISO 16232
ƒƒ Emulsions
ƒƒ ISO 4406
ƒƒ High levels of contamination
ƒƒ NAS 1638
ƒƒ Very high viscosities (dilution required)
ƒƒ Any user defined standard
ƒƒ Water Glycol based fluids

ƒƒ Oil based fluids

REV 09/2018
I n t h e w o r l d o f pa r t I c l e s pa m a s c o u n t s
PAMAS FastPatch 2 GO
Standardised membrane filter analysis
through an advanced automated particle counting system
The PAMAS FastPatch 2 GO The clear and concise user Key Features include:
Technical data:
microscope system has been defined end report displays the
developed to comply with the full patch analysis overview and ƒƒ Optimised LED ringlight Product Specifications:
standard ISO 4407 as an auto- the contamination classification illumination with polarisation
mated filter membrane particle table. The user can capture im- function enabling metallic / ƒƒ Automated particle count analysis
ages from any area of the filter non-metallic particle detection. system for filter membranes
counting and sizing system. The
system is designed to analyse the membrane and add them to the ƒƒ High resolution
particles trapped on the surface end report with the size of each ƒƒ Presentation of counts in to see small particles
of the filter. The analysis uses particle displayed. The accordance with a particle
advanced image analysis and mi- PAMAS FastPatch 2 GO length classification. The ƒƒ Full correct filter patch result for
non-uniform particle distribution
croscope automation techniques system complies with the inter- classification used may be
to provide rapid and accurate national standard ISO 4407 and that of a recognized standard, ƒƒ Compensation for
contamination results of whole provides results to the following such as ISO 16232, SAE background colouration
or user specified areas of filters. standards: SAE AS 4059, ISO AS4059, ISO 4406 or one
16232, NAS 1638 and ISO 4406. defined by the user. ƒƒ Reduced sample preparation time
Cross contamination and uneven
membrane filter issues are both ƒƒ Compliance with international
eliminated by encasing the patch Included hardware: ƒƒ Comprehensive analysis of the standard ISO 4407; reported to
within a slide mount. This also The PAMAS FastPatch 2 GO entire membrane filter patch. SAE AS 4059, NAS 1638, ISO 4406
enables multiple analyses of the system includes its own laptop or ISO 16232 standards
same sample should the user or preloaded with the software ƒƒ Specific treatment for
customer require it. The accurate application required for analysis. particulates in contact The PAMAS FastPatch 2 GO
and repeatable measuring results This software programme with the edge of the image. includes:
of the PAMAS FastPatch 2 GO is designed for membrane analy-
sis and measures a wide variety ƒƒ High Resolution,
are displayed in real time: provid- fixed magnification
ing a constantly updated particle of parameters, including the optical microsystem
count and contamination class measurement of the particles
results table. length, width and area. ƒƒ Integrated high definition camera

ƒƒ motorised X/Y staging with joystick

ƒƒ Optimised LED ringlight illumination


with integrated polarising filter. The
polarising filter can be switched on
or off and enables visualisation of
metallic / non-metallic particles.

ƒƒ Calibration graticule
with certification

Registered trademarks are properties of their individual owners. All specifications are subject to change without notice.
ƒƒ High performance laptop
pre-configured with
the analysis software

Size:
1000 x 600 x 600 mm

Weight:
30 kg

The PAMAS FastPatch 2 GO produces quick and accurate analytic results with the The LED ringlight provides incidental
length, width and area of each particle recorded. The report of the microscopic analysis uniform white illumination to the entire
includes digital pictures of the membrane filtered samples according to ISO 4407. membrane filter patch.
Results of the same sample are repeatable, regardless of the patch orientation or
timescales between analyses.

PAMAS HEAD OFFICE Dieselstraße 10, D-71277 Rutesheim, Phone: +49 7152 99 63 0, Fax: +49 7152 99 63-32, Email: [email protected]
PAMAS USA 1408 South Denver Avenue, Tulsa, OK 74119 USA, Phone: +1 918 743 6762, Fax: +1 918 743 6917, Email: [email protected]
PAMAS Benelux Mechelen Campus, Schaliënhoevedreef 20T, B-2800 Mechelen, Phone: +32 15 28 20 10, Mobile: +32 477 42 48 62, Email: [email protected]
PAMAS France Route du Tailleur 210/136, F-40170 Saint-Julien-en-Born, Mobile +33 6 25 33 20 41, Email: [email protected]
PAMAS LATIN AMERICA Curitiba-Paraná, Brazil, Phone/Fax: +55 41 3022 5445, Mobile: +55 41 999 72 21 73, Email: [email protected]
PAMAS INDIA No. 203, I floor, Oxford House, #15 Rustam Bagh Main Road, Bangalore 560017, India, Phone: +91 80 41 15 00 39, Email: [email protected]
PAMAS HISPANIA Calle Zubilleta No. 13 1°B, ES-48991 Algorta, Mobile: +34 67 75 39 699, Email: [email protected]
PAMAS UK Sci-Tech Daresbury, Keckwick Lane, Daresbury, Cheshire WA4 4FS, Mobile: +44 79 17 71 33 66, Email: [email protected]