0% found this document useful (0 votes)
36 views2 pages

Three Phase NOTES

This document discusses three-phase circuits and connections. It describes two configurations for three-phase sources: wye and delta. It also discusses balanced wye-wye, delta-delta, wye-delta, and delta-wye connections. The key relationships between phase and line voltages and currents are defined for each configuration. Single-phase equivalents are presented for balanced wye-wye and delta-delta connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views2 pages

Three Phase NOTES

This document discusses three-phase circuits and connections. It describes two configurations for three-phase sources: wye and delta. It also discusses balanced wye-wye, delta-delta, wye-delta, and delta-wye connections. The key relationships between phase and line voltages and currents are defined for each configuration. Single-phase equivalents are presented for balanced wye-wye and delta-delta connections.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ENGR 12 Ch 12 Three Phase Circuits

Two Different Three-phase Source configurations:

Wye Source (for Load just reverse all currents): Delta Source (for Load just reverse all currents):

Phase Voltages Van, Vbn, Vcn Phase Voltages and Line Voltages are the same
Line Voltages Vab, Vbc, Vca Vab, Vbc, Vca are phase and line voltages

(KVL:) Vab = Van –Vbn = Van/+30 (abc) Phase Currents Iab, Ibc, Ica
= Van/-30 (acb) Line Currents Ia, Ib, Ic

Phase Currents and Line Currents are the same (KCL:) Ia = Iab – Ica = Iab/-30 (abc)
Ia, Ib, Ic are phase and line currents = Iab/+30 (acb)

Delta Currents – (abc) (acb)


Wye Voltages (abc) (acb)
Balanced Y-Y Connection:

Single Phase Equivalent

Ia = Van / Zy and all other Voltages and Currents


found by using phase relationships above

Balanced Delta – Delta Connection

Iab = Vab / Z


Ibc = Vbc / Z
Ica = Vca / Z

(abc)
Ia = Iab – Ica = Iab/-30 (+30 acb)
Ib = Ibc – Iab = Ibc/-30
Ic = Ica – Ibc = Ica/-30

Balanced Wye – Delta Connection

Iab = Vab / Z


Ibc = Vbc / Z
Ica = Vca / Z

(abc)
Ia = Iab – Ica = Iab/-30 (+30 acb)
Ib = Ibc – Iab = Ibc/-30
Ic = Ica – Ibc = Ica/-30

Delta-Wye Conversions: using R below but Z works the same way:

BALANCED: IF R1 = R2 = R3 = RY and Ra=Rb=Rc = R, then R = 3RY, and RY = R/3